Internet Engineering Task Force (IETF)                   A. Sajassi, Ed.Request for Comments: 8365                                         CiscoCategory: Standards Track                                  J. Drake, Ed.ISSN: 2070-1721                                                  Juniper                                                                N. Bitar                                                                   Nokia                                                              R. Shekhar                                                                 Juniper                                                               J. Uttaro                                                                    AT&T                                                           W. Henderickx                                                                   Nokia                                                              March 2018A Network Virtualization Overlay Solution Using Ethernet VPN (EVPN)Abstract   This document specifies how Ethernet VPN (EVPN) can be used as a   Network Virtualization Overlay (NVO) solution and explores the   various tunnel encapsulation options over IP and their impact on the   EVPN control plane and procedures.  In particular, the following   encapsulation options are analyzed: Virtual Extensible LAN (VXLAN),   Network Virtualization using Generic Routing Encapsulation (NVGRE),   and MPLS over GRE.  This specification is also applicable to Generic   Network Virtualization Encapsulation (GENEVE); however, some   incremental work is required, which will be covered in a separate   document.  This document also specifies new multihoming procedures   for split-horizon filtering and mass withdrawal.  It also specifies   EVPN route constructions for VXLAN/NVGRE encapsulations and   Autonomous System Border Router (ASBR) procedures for multihoming of   Network Virtualization Edge (NVE) devices.Status of This Memo   This is an Internet Standards Track document.   This document is a product of the Internet Engineering Task Force   (IETF).  It represents the consensus of the IETF community.  It has   received public review and has been approved for publication by the   Internet Engineering Steering Group (IESG).  Further information on   Internet Standards is available inSection 2 of RFC 7841.   Information about the current status of this document, any errata,   and how to provide feedback on it may be obtained athttps://www.rfc-editor.org/info/rfc8365.Sajassi, et al.              Standards Track                    [Page 1]

RFC 8365         Network Virtualization Overlay Solution      March 2018Copyright Notice   Copyright (c) 2018 IETF Trust and the persons identified as the   document authors.  All rights reserved.   This document is subject toBCP 78 and the IETF Trust's Legal   Provisions Relating to IETF Documents   (https://trustee.ietf.org/license-info) in effect on the date of   publication of this document.  Please review these documents   carefully, as they describe your rights and restrictions with respect   to this document.  Code Components extracted from this document must   include Simplified BSD License text as described in Section 4.e of   the Trust Legal Provisions and are provided without warranty as   described in the Simplified BSD License.Sajassi, et al.              Standards Track                    [Page 2]

RFC 8365         Network Virtualization Overlay Solution      March 2018Table of Contents1. Introduction ....................................................42. Requirements Notation and Conventions ...........................53. Terminology .....................................................54. EVPN Features ...................................................75. Encapsulation Options for EVPN Overlays .........................85.1. VXLAN/NVGRE Encapsulation ..................................85.1.1. Virtual Identifiers Scope ...........................95.1.2. Virtual Identifiers to EVI Mapping .................115.1.3. Constructing EVPN BGP Routes .......................135.2. MPLS over GRE .............................................156. EVPN with Multiple Data-Plane Encapsulations ...................157. Single-Homing NVEs - NVE Residing in Hypervisor ................167.1. Impact on EVPN BGP Routes & Attributes for VXLAN/NVGRE ....167.2. Impact on EVPN Procedures for VXLAN/NVGRE Encapsulations ..178. Multihoming NVEs - NVE Residing in ToR Switch ..................188.1. EVPN Multihoming Features .................................188.1.1. Multihomed ES Auto-Discovery .......................188.1.2. Fast Convergence and Mass Withdrawal ...............188.1.3. Split-Horizon ......................................198.1.4. Aliasing and Backup Path ...........................198.1.5. DF Election ........................................208.2. Impact on EVPN BGP Routes and Attributes ..................208.3. Impact on EVPN Procedures .................................208.3.1. Split Horizon ......................................218.3.2. Aliasing and Backup Path ...........................228.3.3. Unknown Unicast Traffic Designation ................229. Support for Multicast ..........................................2310. Data-Center Interconnections (DCIs) ...........................2410.1. DCI Using GWs ............................................2410.2. DCI Using ASBRs ..........................................2410.2.1. ASBR Functionality with Single-Homing NVEs ........2510.2.2. ASBR Functionality with Multihoming NVEs ..........2611. Security Considerations .......................................2812. IANA Considerations ...........................................2913. References ....................................................2913.1. Normative References .....................................2913.2. Informative References ...................................30   Acknowledgements ..................................................32   Contributors ......................................................32   Authors' Addresses ................................................33Sajassi, et al.              Standards Track                    [Page 3]

RFC 8365         Network Virtualization Overlay Solution      March 20181.  Introduction   This document specifies how Ethernet VPN (EVPN) [RFC7432] can be used   as a Network Virtualization Overlay (NVO) solution and explores the   various tunnel encapsulation options over IP and their impact on the   EVPN control plane and procedures.  In particular, the following   encapsulation options are analyzed: Virtual Extensible LAN (VXLAN)   [RFC7348], Network Virtualization using Generic Routing Encapsulation   (NVGRE) [RFC7637], and MPLS over Generic Routing Encapsulation (GRE)   [RFC4023].  This specification is also applicable to Generic Network   Virtualization Encapsulation (GENEVE) [GENEVE]; however, some   incremental work is required, which will be covered in a separate   document [EVPN-GENEVE].  This document also specifies new multihoming   procedures for split-horizon filtering and mass withdrawal.  It also   specifies EVPN route constructions for VXLAN/NVGRE encapsulations and   Autonomous System Border Router (ASBR) procedures for multihoming of   Network Virtualization Edge (NVE) devices.   In the context of this document, an NVO is a solution to address the   requirements of a multi-tenant data center, especially one with   virtualized hosts, e.g., Virtual Machines (VMs) or virtual workloads.   The key requirements of such a solution, as described in [RFC7364],   are the following:   -  Isolation of network traffic per tenant   -  Support for a large number of tenants (tens or hundreds of      thousands)   -  Extension of Layer 2 (L2) connectivity among different VMs      belonging to a given tenant segment (subnet) across different      Points of Delivery (PoDs) within a data center or between      different data centers   -  Allowing a given VM to move between different physical points of      attachment within a given L2 segment   The underlay network for NVO solutions is assumed to provide IP   connectivity between NVO endpoints.Sajassi, et al.              Standards Track                    [Page 4]

RFC 8365         Network Virtualization Overlay Solution      March 2018   This document describes how EVPN can be used as an NVO solution and   explores applicability of EVPN functions and procedures.  In   particular, it describes the various tunnel encapsulation options for   EVPN over IP and their impact on the EVPN control plane as well as   procedures for two main scenarios:   (a)  single-homing NVEs - when an NVE resides in the hypervisor, and   (b)  multihoming NVEs - when an NVE resides in a Top-of-Rack (ToR)        device.   The possible encapsulation options for EVPN overlays that are   analyzed in this document are:   -  VXLAN and NVGRE   -  MPLS over GRE   Before getting into the description of the different encapsulation   options for EVPN over IP, it is important to highlight the EVPN   solution's main features, how those features are currently supported,   and any impact that the encapsulation has on those features.2.  Requirements Notation and Conventions   The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",   "SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and   "OPTIONAL" in this document are to be interpreted as described inBCP 14 [RFC2119] [RFC8174] when, and only when, they appear in all   capitals, as shown here.3.  Terminology   Most of the terminology used in this documents comes from [RFC7432]   and [RFC7365].   VXLAN:  Virtual Extensible LAN   GRE:  Generic Routing Encapsulation   NVGRE:  Network Virtualization using Generic Routing Encapsulation   GENEVE:  Generic Network Virtualization Encapsulation   PoD:  Point of Delivery   NV:  Network VirtualizationSajassi, et al.              Standards Track                    [Page 5]

RFC 8365         Network Virtualization Overlay Solution      March 2018   NVO:  Network Virtualization Overlay   NVE:  Network Virtualization Edge   VNI:  VXLAN Network Identifier   VSID:  Virtual Subnet Identifier (for NVGRE)   I-SID:  Service Instance Identifier   EVPN:  Ethernet VPN   EVI:  EVPN Instance.  An EVPN instance spanning the Provider Edge      (PE) devices participating in that EVPN   MAC-VRF:  A Virtual Routing and Forwarding table for Media Access      Control (MAC) addresses on a PE   IP-VRF:  A Virtual Routing and Forwarding table for Internet Protocol      (IP) addresses on a PE   ES:  Ethernet Segment.  When a customer site (device or network) is      connected to one or more PEs via a set of Ethernet links, then      that set of links is referred to as an 'Ethernet segment'.   Ethernet Segment Identifier (ESI):  A unique non-zero identifier that      identifies an Ethernet segment is called an 'Ethernet Segment      Identifier'.   Ethernet Tag:  An Ethernet tag identifies a particular broadcast      domain, e.g., a VLAN.  An EVPN instance consists of one or more      broadcast domains.   PE:  Provider Edge   Single-Active Redundancy Mode:  When only a single PE, among all the      PEs attached to an ES, is allowed to forward traffic to/from that      ES for a given VLAN, then the Ethernet segment is defined to be      operating in Single-Active redundancy mode.   All-Active Redundancy Mode:  When all PEs attached to an Ethernet      segment are allowed to forward known unicast traffic to/from that      ES for a given VLAN, then the ES is defined to be operating in      All-Active redundancy mode.   PIM-SM:  Protocol Independent Multicast - Sparse-ModeSajassi, et al.              Standards Track                    [Page 6]

RFC 8365         Network Virtualization Overlay Solution      March 2018   PIM-SSM:  Protocol Independent Multicast - Source-Specific Multicast   BIDIR-PIM:  Bidirectional PIM4.  EVPN Features   EVPN [RFC7432] was originally designed to support the requirements   detailed in [RFC7209] and therefore has the following attributes   which directly address control-plane scaling and ease of deployment   issues.   1.   Control-plane information is distributed with BGP and broadcast        and multicast traffic is sent using a shared multicast tree or        with ingress replication.   2.   Control-plane learning is used for MAC (and IP) addresses        instead of data-plane learning.  The latter requires the        flooding of unknown unicast and Address Resolution Protocol        (ARP) frames; whereas, the former does not require any flooding.   3.   Route Reflector (RR) is used to reduce a full mesh of BGP        sessions among PE devices to a single BGP session between a PE        and the RR.  Furthermore, RR hierarchy can be leveraged to scale        the number of BGP routes on the RR.   4.   Auto-discovery via BGP is used to discover PE devices        participating in a given VPN, PE devices participating in a        given redundancy group, tunnel encapsulation types, multicast        tunnel types, multicast members, etc.   5.   All-Active multihoming is used.  This allows a given Customer        Edge (CE) device to have multiple links to multiple PEs, and        traffic to/from that CE fully utilizes all of these links.   6.   When a link between a CE and a PE fails, the PEs for that EVI        are notified of the failure via the withdrawal of a single EVPN        route.  This allows those PEs to remove the withdrawing PE as a        next hop for every MAC address associated with the failed link.        This is termed "mass withdrawal".   7.   BGP route filtering and constrained route distribution are        leveraged to ensure that the control-plane traffic for a given        EVI is only distributed to the PEs in that EVI.Sajassi, et al.              Standards Track                    [Page 7]

RFC 8365         Network Virtualization Overlay Solution      March 2018   8.   When an IEEE 802.1Q [IEEE.802.1Q] interface is used between a CE        and a PE, each of the VLAN IDs (VIDs) on that interface can be        mapped onto a bridge table (for up to 4094 such bridge tables).        All these bridge tables may be mapped onto a single MAC-VRF (in        case of VLAN-aware bundle service).   9.   VM Mobility mechanisms ensure that all PEs in a given EVI know        the ES with which a given VM, as identified by its MAC and IP        addresses, is currently associated.   10.  RTs are used to allow the operator (or customer) to define a        spectrum of logical network topologies including mesh, hub and        spoke, and extranets (e.g., a VPN whose sites are owned by        different enterprises), without the need for proprietary        software or the aid of other virtual or physical devices.   Because the design goal for NVO is millions of instances per common   physical infrastructure, the scaling properties of the control plane   for NVO are extremely important.  EVPN and the extensions described   herein, are designed with this level of scalability in mind.5.  Encapsulation Options for EVPN Overlays5.1.  VXLAN/NVGRE Encapsulation   Both VXLAN and NVGRE are examples of technologies that provide a data   plane encapsulation which is used to transport a packet over the   common physical IP infrastructure between Network Virtualization   Edges (NVEs) - e.g., VXLAN Tunnel End Points (VTEPs) in VXLAN   network.  Both of these technologies include the identifier of the   specific NVO instance, VNI in VXLAN and VSID in NVGRE, in each   packet.  In the remainder of this document we use VNI as the   representation for NVO instance with the understanding that VSID can   equally be used if the encapsulation is NVGRE unless it is stated   otherwise.   Note that a PE is equivalent to an NVE/VTEP.   VXLAN encapsulation is based on UDP, with an 8-byte header following   the UDP header.  VXLAN provides a 24-bit VNI, which typically   provides a one-to-one mapping to the tenant VID, as described in   [RFC7348].  In this scenario, the ingress VTEP does not include an   inner VLAN tag on the encapsulated frame, and the egress VTEP   discards the frames with an inner VLAN tag.  This mode of operation   in [RFC7348] maps to VLAN-Based Service in [RFC7432], where a tenant   VID gets mapped to an EVI.Sajassi, et al.              Standards Track                    [Page 8]

RFC 8365         Network Virtualization Overlay Solution      March 2018   VXLAN also provides an option of including an inner VLAN tag in the   encapsulated frame, if explicitly configured at the VTEP.  This mode   of operation can map to VLAN Bundle Service in [RFC7432] because all   the tenant's tagged frames map to a single bridge table / MAC-VRF,   and the inner VLAN tag is not used for lookup by the disposition PE   when performing VXLAN decapsulation as described inSection 6 of   [RFC7348].   [RFC7637] encapsulation is based on GRE encapsulation, and it   mandates the inclusion of the optional GRE Key field, which carries   the VSID.  There is a one-to-one mapping between the VSID and the   tenant VID, as described in [RFC7637].  The inclusion of an inner   VLAN tag is prohibited.  This mode of operation in [RFC7637] maps to   VLAN Based Service in [RFC7432].   As described in the next section, there is no change to the encoding   of EVPN routes to support VXLAN or NVGRE encapsulation, except for   the use of the BGP Encapsulation Extended Community to indicate the   encapsulation type (e.g., VXLAN or NVGRE).  However, there is   potential impact to the EVPN procedures depending on where the NVE is   located (i.e., in hypervisor or ToR) and whether multihoming   capabilities are required.5.1.1.  Virtual Identifiers Scope   Although VNIs are defined as 24-bit globally unique values, there are   scenarios in which it is desirable to use a locally significant value   for the VNI, especially in the context of a data-center interconnect.5.1.1.1.  Data-Center Interconnect with Gateway   In the case where NVEs in different data centers need to be   interconnected, and the NVEs need to use VNIs as globally unique   identifiers within a data center, then a Gateway (GW) needs to be   employed at the edge of the data-center network (DCN).  This is   because the Gateway will provide the functionality of translating the   VNI when crossing network boundaries, which may align with operator   span-of-control boundaries.  As an example, consider the network of   Figure 1.  Assume there are three network operators: one for each of   the DC1, DC2, and WAN networks.  The Gateways at the edge of the data   centers are responsible for translating the VNIs between the values   used in each of the DCNs and the values used in the WAN.Sajassi, et al.              Standards Track                    [Page 9]

RFC 8365         Network Virtualization Overlay Solution      March 2018                             +--------------+                             |              |           +---------+       |     WAN      |       +---------+   +----+  |        +---+  +----+        +----+  +---+        |  +----+   |NVE1|--|        |   |  |WAN |        |WAN |  |   |        |--|NVE3|   +----+  |IP      |GW |--|Edge|        |Edge|--|GW | IP     |  +----+   +----+  |Fabric  +---+  +----+        +----+  +---+ Fabric |  +----+   |NVE2|--|         |       |              |       |         |--|NVE4|   +----+  +---------+       +--------------+       +---------+  +----+   |<------ DC 1 ------>                          <------ DC2  ------>|              Figure 1: Data-Center Interconnect with Gateway5.1.1.2.  Data-Center Interconnect without Gateway   In the case where NVEs in different data centers need to be   interconnected, and the NVEs need to use locally assigned VNIs (e.g.,   similar to MPLS labels), there may be no need to employ Gateways at   the edge of the DCN.  More specifically, the VNI value that is used   by the transmitting NVE is allocated by the NVE that is receiving the   traffic (in other words, this is similar to a "downstream-assigned"   MPLS label).  This allows the VNI space to be decoupled between   different DCNs without the need for a dedicated Gateway at the edge   of the data centers.  This topic is covered inSection 10.2.                              +--------------+                              |              |              +---------+     |     WAN      |    +---------+      +----+  |         |   +----+        +----+  |         |  +----+      |NVE1|--|         |   |ASBR|        |ASBR|  |         |--|NVE3|      +----+  |IP Fabric|---|    |        |    |--|IP Fabric|  +----+      +----+  |         |   +----+        +----+  |         |  +----+      |NVE2|--|         |     |              |    |         |--|NVE4|      +----+  +---------+     +--------------+    +---------+  +----+      |<------ DC 1 ----->                        <---- DC2  ------>|               Figure 2: Data-Center Interconnect with ASBRSajassi, et al.              Standards Track                   [Page 10]

RFC 8365         Network Virtualization Overlay Solution      March 20185.1.2.  Virtual Identifiers to EVI Mapping   Just like in [RFC7432], where two options existed for mapping   broadcast domains (represented by VLAN IDs) to an EVI, when the EVPN   control plane is used in conjunction with VXLAN (or NVGRE   encapsulation), there are also two options for mapping broadcast   domains represented by VXLAN VNIs (or NVGRE VSIDs) to an EVI:      Option 1: A Single Broadcast Domain per EVI   In this option, a single Ethernet broadcast domain (e.g., subnet)   represented by a VNI is mapped to a unique EVI.  This corresponds to   the VLAN-Based Service in [RFC7432], where a tenant-facing interface,   logical interface (e.g., represented by a VID), or physical interface   gets mapped to an EVI.  As such, a BGP Route Distinguisher (RD) and   Route Target (RT) are needed per VNI on every NVE.  The advantage of   this model is that it allows the BGP RT constraint mechanisms to be   used in order to limit the propagation and import of routes to only   the NVEs that are interested in a given VNI.  The disadvantage of   this model may be the provisioning overhead if the RD and RT are not   derived automatically from the VNI.   In this option, the MAC-VRF table is identified by the RT in the   control plane and by the VNI in the data plane.  In this option, the   specific MAC-VRF table corresponds to only a single bridge table.      Option 2: Multiple Broadcast Domains per EVI   In this option, multiple subnets, each represented by a unique VNI,   are mapped to a single EVI.  For example, if a tenant has multiple   segments/subnets each represented by a VNI, then all the VNIs for   that tenant are mapped to a single EVI; for example, the EVI in this   case represents the tenant and not a subnet.  This corresponds to the   VLAN-aware bundle service in [RFC7432].  The advantage of this model   is that it doesn't require the provisioning of an RD/RT per VNI.   However, this is a moot point when compared to Option 1 where auto-   derivation is used.  The disadvantage of this model is that routes   would be imported by NVEs that may not be interested in a given VNI.   In this option, the MAC-VRF table is identified by the RT in the   control plane; a specific bridge table for that MAC-VRF is identified   by the <RT, Ethernet Tag ID> in the control plane.  In this option,   the VNI in the data plane is sufficient to identify a specific bridge   table.Sajassi, et al.              Standards Track                   [Page 11]

RFC 8365         Network Virtualization Overlay Solution      March 20185.1.2.1.  Auto-Derivation of RT   In order to simplify configuration, when the option of a single VNI   per EVI is used, the RT used for EVPN can be auto-derived.  RD can be   auto-generated as described in [RFC7432], and RT can be auto-derived   as described next.   Since a Gateway PE as depicted in Figure 1 participates in both the   DCN and WAN BGP sessions, it is important that, when RT values are   auto-derived from VNIs, there be no conflict in RT spaces between   DCNs and WANs, assuming that both are operating within the same   Autonomous System (AS).  Also, there can be scenarios where both   VXLAN and NVGRE encapsulations may be needed within the same DCN, and   their corresponding VNIs are administered independently, which means   VNI spaces can overlap.  In order to avoid conflict in RT spaces, the   6-byte RT values with 2-octet AS number for DCNs can be auto-derived   as follow:    0                   1                   2                   3    0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+   |     Global Administrator      |    Local Administrator        |   +-----------------------------------------------+---------------+   | Local Administrator (Cont.)   |   +-------------------------------+    0                   1                   2                   3    0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+   |     Global Administrator      |A| TYPE| D-ID  | Service ID    |   +-----------------------------------------------+---------------+   |       Service ID (Cont.)      |   +-------------------------------+   The 6-octet RT field consists of two sub-fields:   -  Global Administrator sub-field: 2 octets.  This sub-field contains      an AS number assigned by IANA <https://www.iana.org/assignments/as-numbers/>.   -  Local Administrator sub-field: 4 octets      *  A: A single-bit field indicating if this RT is auto-derived            0: auto-derived            1: manually derivedSajassi, et al.              Standards Track                   [Page 12]

RFC 8365         Network Virtualization Overlay Solution      March 2018      *  Type: A 3-bit field that identifies the space in which the         other 3 bytes are defined.  The following spaces are defined:            0 : VID (802.1Q VLAN ID)            1 : VXLAN            2 : NVGRE            3 : I-SID            4 : EVI            5 : dual-VID (QinQ VLAN ID)      *  D-ID: A 4-bit field that identifies domain-id.  The default         value of domain-id is zero, indicating that only a single         numbering space exist for a given technology.  However, if more         than one number space exists for a given technology (e.g.,         overlapping VXLAN spaces), then each of the number spaces need         to be identified by its corresponding domain-id starting from         1.      *  Service ID: This 3-octet field is set to VNI, VSID, I-SID, or         VID.   It should be noted that RT auto-derivation is applicable for 2-octet   AS numbers.  For 4-octet AS numbers, the RT needs to be manually   configured because 3-octet VNI fields cannot be fit within the   2-octet local administrator field.5.1.3.  Constructing EVPN BGP Routes   In EVPN, an MPLS label, for instance, identifying the forwarding   table is distributed by the egress PE via the EVPN control plane and   is placed in the MPLS header of a given packet by the ingress PE.   This label is used upon receipt of that packet by the egress PE for   disposition of that packet.  This is very similar to the use of the   VNI by the egress NVE, with the difference being that an MPLS label   has local significance while a VNI typically has global significance.   Accordingly, and specifically to support the option of locally   assigned VNIs, the MPLS Label1 field in the MAC/IP Advertisement   route, the MPLS label field in the Ethernet A-D per EVI route, and   the MPLS label field in the P-Multicast Service Interface (PMSI)   Tunnel attribute of the Inclusive Multicast Ethernet Tag (IMET) route   are used to carry the VNI.  For the balance of this memo, the above   MPLS label fields will be referred to as the VNI field.  The VNI   field is used for both local and global VNIs; for either case, the   entire 24-bit field is used to encode the VNI value.Sajassi, et al.              Standards Track                   [Page 13]

RFC 8365         Network Virtualization Overlay Solution      March 2018   For the VLAN-Based Service (a single VNI per MAC-VRF), the Ethernet   Tag field in the MAC/IP Advertisement, Ethernet A-D per EVI, and IMET   route MUST be set to zero just as in the VLAN-Based Service in   [RFC7432].   For the VLAN-Aware Bundle Service (multiple VNIs per MAC-VRF with   each VNI associated with its own bridge table), the Ethernet Tag   field in the MAC Advertisement, Ethernet A-D per EVI, and IMET route   MUST identify a bridge table within a MAC-VRF; the set of Ethernet   Tags for that EVI needs to be configured consistently on all PEs   within that EVI.  For locally assigned VNIs, the value advertised in   the Ethernet Tag field MUST be set to a VID just as in the VLAN-aware   bundle service in [RFC7432].  Such setting must be done consistently   on all PE devices participating in that EVI within a given domain.   For global VNIs, the value advertised in the Ethernet Tag field   SHOULD be set to a VNI as long as it matches the existing semantics   of the Ethernet Tag, i.e., it identifies a bridge table within a   MAC-VRF and the set of VNIs are configured consistently on each PE in   that EVI.   In order to indicate which type of data-plane encapsulation (i.e.,   VXLAN, NVGRE, MPLS, or MPLS in GRE) is to be used, the BGP   Encapsulation Extended Community defined in [RFC5512] is included   with all EVPN routes (i.e., MAC Advertisement, Ethernet A-D per EVI,   Ethernet A-D per ESI, IMET, and Ethernet Segment) advertised by an   egress PE.  Five new values have been assigned by IANA to extend the   list of encapsulation types defined in [RFC5512]; they are listed inSection 11.   The MPLS encapsulation tunnel type, listed inSection 11, is needed   in order to distinguish between an advertising node that only   supports non-MPLS encapsulations and one that supports MPLS and   non-MPLS encapsulations.  An advertising node that only supports MPLS   encapsulation does not need to advertise any encapsulation tunnel   types; i.e., if the BGP Encapsulation Extended Community is not   present, then either MPLS encapsulation or a statically configured   encapsulation is assumed.   The Next Hop field of the MP_REACH_NLRI attribute of the route MUST   be set to the IPv4 or IPv6 address of the NVE.  The remaining fields   in each route are set as per [RFC7432].   Note that the procedure defined here -- to use the MPLS Label field   to carry the VNI in the presence of a Tunnel Encapsulation Extended   Community specifying the use of a VNI -- is aligned with the   procedures described in Section 8.2.2.2 of [TUNNEL-ENCAP] ("When a   Valid VNI has not been Signaled").Sajassi, et al.              Standards Track                   [Page 14]

RFC 8365         Network Virtualization Overlay Solution      March 20185.2.  MPLS over GRE   The EVPN data plane is modeled as an EVPN MPLS client layer sitting   over an MPLS PSN tunnel server layer.  Some of the EVPN functions   (split-horizon, Aliasing, and Backup Path) are tied to the MPLS   client layer.  If MPLS over GRE encapsulation is used, then the EVPN   MPLS client layer can be carried over an IP PSN tunnel transparently.   Therefore, there is no impact to the EVPN procedures and associated   data-plane operation.   [RFC4023] defines the standard for using MPLS over GRE encapsulation,   which can be used for this purpose.  However, when MPLS over GRE is   used in conjunction with EVPN, it is recommended that the GRE key   field be present and be used to provide a 32-bit entropy value only   if the P nodes can perform Equal-Cost Multipath (ECMP) hashing based   on the GRE key; otherwise, the GRE header SHOULD NOT include the GRE   key field.  The Checksum and Sequence Number fields MUST NOT be   included, and the corresponding C and S bits in the GRE header MUST   be set to zero.  A PE capable of supporting this encapsulation SHOULD   advertise its EVPN routes along with the Tunnel Encapsulation   Extended Community indicating MPLS over GRE encapsulation as   described in the previous section.6.  EVPN with Multiple Data-Plane Encapsulations   The use of the BGP Encapsulation Extended Community per [RFC5512]   allows each NVE in a given EVI to know each of the encapsulations   supported by each of the other NVEs in that EVI.  That is, each of   the NVEs in a given EVI may support multiple data-plane   encapsulations.  An ingress NVE can send a frame to an egress NVE   only if the set of encapsulations advertised by the egress NVE forms   a non-empty intersection with the set of encapsulations supported by   the ingress NVE; it is at the discretion of the ingress NVE which   encapsulation to choose from this intersection.  (As noted inSection 5.1.3, if the BGP Encapsulation extended community is not   present, then the default MPLS encapsulation or a locally configured   encapsulation is assumed.)   When a PE advertises multiple supported encapsulations, it MUST   advertise encapsulations that use the same EVPN procedures including   procedures associated with split-horizon filtering described inSection 8.3.1.  For example, VXLAN and NVGRE (or MPLS and MPLS over   GRE) encapsulations use the same EVPN procedures; thus, a PE can   advertise both of them and can support either of them or both of them   simultaneously.  However, a PE MUST NOT advertise VXLAN and MPLS   encapsulations together because (a) the MPLS field of EVPN routes isSajassi, et al.              Standards Track                   [Page 15]

RFC 8365         Network Virtualization Overlay Solution      March 2018   set to either an MPLS label or a VNI, but not both and (b) some EVPN   procedures (such as split-horizon filtering) are different for VXLAN/   NVGRE and MPLS encapsulations.   An ingress node that uses shared multicast trees for sending   broadcast or multicast frames MAY maintain distinct trees for each   different encapsulation type.   It is the responsibility of the operator of a given EVI to ensure   that all of the NVEs in that EVI support at least one common   encapsulation.  If this condition is violated, it could result in   service disruption or failure.  The use of the BGP Encapsulation   Extended Community provides a method to detect when this condition is   violated, but the actions to be taken are at the discretion of the   operator and are outside the scope of this document.7.  Single-Homing NVEs - NVE Residing in Hypervisor   When an NVE and its hosts/VMs are co-located in the same physical   device, e.g., when they reside in a server, the links between them   are virtual and they typically share fate.  That is, the subject   hosts/VMs are typically not multihomed or, if they are multihomed,   the multihoming is a purely local matter to the server hosting the VM   and the NVEs, and it need not be "visible" to any other NVEs residing   on other servers.  Thus, it does not require any specific protocol   mechanisms.  The most common case of this is when the NVE resides on   the hypervisor.   In the subsections that follow, we will discuss the impact on EVPN   procedures for the case when the NVE resides on the hypervisor and   the VXLAN (or NVGRE) encapsulation is used.7.1.  Impact on EVPN BGP Routes & Attributes for VXLAN/NVGRE      Encapsulations   In scenarios where different groups of data centers are under   different administrative domains, and these data centers are   connected via one or more backbone core providers as described in   [RFC7365], the RD must be a unique value per EVI or per NVE as   described in [RFC7432].  In other words, whenever there is more than   one administrative domain for global VNI, a unique RD must be used;   or, whenever the VNI value has local significance, a unique RD must   be used.  Therefore, it is recommended to use a unique RD as   described in [RFC7432] at all times.Sajassi, et al.              Standards Track                   [Page 16]

RFC 8365         Network Virtualization Overlay Solution      March 2018   When the NVEs reside on the hypervisor, the EVPN BGP routes and   attributes associated with multihoming are no longer required.  This   reduces the required routes and attributes to the following subset of   four out of the total of eight listed inSection 7 of [RFC7432]:   -  MAC/IP Advertisement Route   -  Inclusive Multicast Ethernet Tag Route   -  MAC Mobility Extended Community   -  Default Gateway Extended Community   However, as noted inSection 8.6 of [RFC7432], in order to enable a   single-homing ingress NVE to take advantage of fast convergence,   Aliasing, and Backup Path when interacting with multihomed egress   NVEs attached to a given ES, the single-homing ingress NVE should be   able to receive and process routes that are Ethernet A-D per ES and   Ethernet A-D per EVI.7.2.  Impact on EVPN Procedures for VXLAN/NVGRE Encapsulations   When the NVEs reside on the hypervisors, the EVPN procedures   associated with multihoming are no longer required.  This limits the   procedures on the NVE to the following subset.   1.  Local learning of MAC addresses received from the VMs perSection 10.1 of [RFC7432].   2.  Advertising locally learned MAC addresses in BGP using the MAC/IP       Advertisement routes.   3.  Performing remote learning using BGP perSection 9.2 of       [RFC7432].   4.  Discovering other NVEs and constructing the multicast tunnels       using the IMET routes.   5.  Handling MAC address mobility events per the procedures ofSection 15 in [RFC7432].   However, as noted inSection 8.6 of [RFC7432], in order to enable a   single-homing ingress NVE to take advantage of fast convergence,   Aliasing, and Backup Path when interacting with multihomed egress   NVEs attached to a given ES, a single-homing ingress NVE should   implement the ingress node processing of routes that are Ethernet A-D   per ES and Ethernet A-D per EVI as defined in Sections8.2 ("Fast   Convergence") and 8.4 ("Aliasing and Backup Path") of [RFC7432].Sajassi, et al.              Standards Track                   [Page 17]

RFC 8365         Network Virtualization Overlay Solution      March 20188.  Multihoming NVEs - NVE Residing in ToR Switch   In this section, we discuss the scenario where the NVEs reside in the   ToR switches AND the servers (where VMs are residing) are multihomed   to these ToR switches.  The multihoming NVE operates in All-Active or   Single-Active redundancy mode.  If the servers are single-homed to   the ToR switches, then the scenario becomes similar to that where the   NVE resides on the hypervisor, as discussed inSection 7, as far as   the required EVPN functionality is concerned.   [RFC7432] defines a set of BGP routes, attributes, and procedures to   support multihoming.  We first describe these functions and   procedures, then discuss which of these are impacted by the VXLAN (or   NVGRE) encapsulation and what modifications are required.  As will be   seen later in this section, the only EVPN procedure that is impacted   by non-MPLS overlay encapsulation (e.g., VXLAN or NVGRE) where it   provides space for one ID rather than a stack of labels, is that of   split-horizon filtering for multihomed ESs described inSection 8.3.1.8.1.  EVPN Multihoming Features   In this section, we will recap the multihoming features of EVPN to   highlight the encapsulation dependencies.  The section only describes   the features and functions at a high level.  For more details, the   reader is to refer to [RFC7432].8.1.1.  Multihomed ES Auto-Discovery   EVPN NVEs (or PEs) connected to the same ES (e.g., the same server   via Link Aggregation Group (LAG)) can automatically discover each   other with minimal to no configuration through the exchange of BGP   routes.8.1.2.  Fast Convergence and Mass Withdrawal   EVPN defines a mechanism to efficiently and quickly signal, to remote   NVEs, the need to update their forwarding tables upon the occurrence   of a failure in connectivity to an ES (e.g., a link or a port   failure).  This is done by having each NVE advertise an Ethernet A-D   route per ES for each locally attached segment.  Upon a failure in   connectivity to the attached segment, the NVE withdraws the   corresponding Ethernet A-D route.  This triggers all NVEs that   receive the withdrawal to update their next-hop adjacencies for all   MAC addresses associated with the ES in question.  If no other NVE   had advertised an Ethernet A-D route for the same segment, then theSajassi, et al.              Standards Track                   [Page 18]

RFC 8365         Network Virtualization Overlay Solution      March 2018   NVE that received the withdrawal simply invalidates the MAC entries   for that segment.  Otherwise, the NVE updates the next-hop adjacency   list accordingly.8.1.3.  Split-Horizon   If a server is multihomed to two or more NVEs (represented by an ES   ES1) and operating in an All-Active redundancy mode, sends a BUM   (i.e., Broadcast, Unknown unicast, or Multicast) packet to one of   these NVEs, then it is important to ensure the packet is not looped   back to the server via another NVE connected to this server.  The   filtering mechanism on the NVE to prevent such loop and packet   duplication is called "split-horizon filtering".8.1.4.  Aliasing and Backup Path   In the case where a station is multihomed to multiple NVEs, it is   possible that only a single NVE learns a set of the MAC addresses   associated with traffic transmitted by the station.  This leads to a   situation where remote NVEs receive MAC Advertisement routes, for   these addresses, from a single NVE even though multiple NVEs are   connected to the multihomed station.  As a result, the remote NVEs   are not able to effectively load-balance traffic among the NVEs   connected to the multihomed ES.  For example, this could be the case   when the NVEs perform data-path learning on the access and the load-   balancing function on the station hashes traffic from a given source   MAC address to a single NVE.  Another scenario where this occurs is   when the NVEs rely on control-plane learning on the access (e.g.,   using ARP), since ARP traffic will be hashed to a single link in the   LAG.   To alleviate this issue, EVPN introduces the concept of "Aliasing".   This refers to the ability of an NVE to signal that it has   reachability to a given locally attached ES, even when it has learned   no MAC addresses from that segment.  The Ethernet A-D route per EVI   is used to that end.  Remote NVEs that receive MAC Advertisement   routes with non-zero ESIs should consider the MAC address as   reachable via all NVEs that advertise reachability to the relevant   Segment using Ethernet A-D routes with the same ESI and with the   Single-Active flag reset.   Backup Path is a closely related function, albeit one that applies to   the case where the redundancy mode is Single-Active.  In this case,   the NVE signals that it has reachability to a given locally attached   ES using the Ethernet A-D route as well.  Remote NVEs that receive   the MAC Advertisement routes, with non-zero ESI, should consider the   MAC address as reachable via the advertising NVE.  Furthermore, the   remote NVEs should install a Backup Path, for said MAC, to the NVESajassi, et al.              Standards Track                   [Page 19]

RFC 8365         Network Virtualization Overlay Solution      March 2018   that had advertised reachability to the relevant segment using an   Ethernet A-D route with the same ESI and with the Single-Active flag   set.8.1.5.  DF Election   If a host is multihomed to two or more NVEs on an ES operating in   All-Active redundancy mode, then, for a given EVI, only one of these   NVEs, termed the "Designated Forwarder" (DF) is responsible for   sending it broadcast, multicast, and, if configured for that EVI,   unknown unicast frames.   This is required in order to prevent duplicate delivery of multi-   destination frames to a multihomed host or VM, in case of All-Active   redundancy.   In NVEs where frames tagged as IEEE 802.1Q [IEEE.802.1Q] are received   from hosts, the DF election should be performed based on host VIDs   perSection 8.5 of [RFC7432].  Furthermore, multihoming PEs of a   given ES MAY perform DF election using configured IDs such as VNI,   EVI, normalized VIDs, and etc., as along the IDs are configured   consistently across the multihoming PEs.   In GWs where VXLAN-encapsulated frames are received, the DF election   is performed on VNIs.  Again, it is assumed that, for a given   Ethernet segment, VNIs are unique and consistent (e.g., no duplicate   VNIs exist).8.2.  Impact on EVPN BGP Routes and Attributes   Since multihoming is supported in this scenario, the entire set of   BGP routes and attributes defined in [RFC7432] is used.  The setting   of the Ethernet Tag field in the MAC Advertisement, Ethernet A-D per   EVI, and IMET) routes follows that ofSection 5.1.3.  Furthermore,   the setting of the VNI field in the MAC Advertisement and Ethernet   A-D per EVI routes follows that ofSection 5.1.3.8.3.  Impact on EVPN Procedures   Two cases need to be examined here, depending on whether the NVEs are   operating in Single-Active or in All-Active redundancy mode.   First, let's consider the case of Single-Active redundancy mode,   where the hosts are multihomed to a set of NVEs; however, only a   single NVE is active at a given point of time for a given VNI.  In   this case, the Aliasing is not required, and the split-horizonSajassi, et al.              Standards Track                   [Page 20]

RFC 8365         Network Virtualization Overlay Solution      March 2018   filtering may not be required, but other functions such as multihomed   ES auto-discovery, fast convergence and mass withdrawal, Backup Path,   and DF election are required.   Second, let's consider the case of All-Active redundancy mode.  In   this case, out of all the EVPN multihoming features listed inSection 8.1, the use of the VXLAN or NVGRE encapsulation impacts the   split-horizon and Aliasing features, since those two rely on the MPLS   client layer.  Given that this MPLS client layer is absent with these   types of encapsulations, alternative procedures and mechanisms are   needed to provide the required functions.  Those are discussed in   detail next.8.3.1.  Split Horizon   In EVPN, an MPLS label is used for split-horizon filtering to support   All-Active multihoming where an ingress NVE adds a label   corresponding to the site of origin (aka an ESI label) when   encapsulating the packet.  The egress NVE checks the ESI label when   attempting to forward a multi-destination frame out an interface, and   if the label corresponds to the same site identifier (ESI) associated   with that interface, the packet gets dropped.  This prevents the   occurrence of forwarding loops.   Since VXLAN and NVGRE encapsulations do not include the ESI label,   other means of performing the split-horizon filtering function must   be devised for these encapsulations.  The following approach is   recommended for split-horizon filtering when VXLAN (or NVGRE)   encapsulation is used.   Every NVE tracks the IP address(es) associated with the other NVE(s)   with which it has shared multihomed ESs.  When the NVE receives a   multi-destination frame from the overlay network, it examines the   source IP address in the tunnel header (which corresponds to the   ingress NVE) and filters out the frame on all local interfaces   connected to ESs that are shared with the ingress NVE.  With this   approach, it is required that the ingress NVE perform replication   locally to all directly attached Ethernet segments (regardless of the   DF election state) for all flooded traffic ingress from the access   interfaces (i.e., from the hosts).  This approach is referred to as   "Local Bias", and has the advantage that only a single IP address   need be used per NVE for split-horizon filtering, as opposed to   requiring an IP address per Ethernet segment per NVE.   In order to allow proper operation of split-horizon filtering among   the same group of multihoming PE devices, a mix of PE devices with   MPLS over GRE encapsulations running the procedures from [RFC7432]Sajassi, et al.              Standards Track                   [Page 21]

RFC 8365         Network Virtualization Overlay Solution      March 2018   for split-horizon filtering on the one hand and VXLAN/NVGRE   encapsulation running local-bias procedures on the other on a given   Ethernet segment MUST NOT be configured.8.3.2.  Aliasing and Backup Path   The Aliasing and the Backup Path procedures for VXLAN/NVGRE   encapsulation are very similar to the ones for MPLS.  In the case of   MPLS, Ethernet A-D route per EVI is used for Aliasing when the   corresponding ES operates in All-Active multihoming, and the same   route is used for Backup Path when the corresponding ES operates in   Single-Active multihoming.  In the case of VXLAN/NVGRE, the same   route is used for the Aliasing and the Backup Path with the   difference that the Ethernet Tag and VNI fields in Ethernet A-D per   EVI route are set as described inSection 5.1.3.8.3.3.  Unknown Unicast Traffic Designation   In EVPN, when an ingress PE uses ingress replication to flood unknown   unicast traffic to egress PEs, the ingress PE uses a different EVPN   MPLS label (from the one used for known unicast traffic) to identify   such BUM traffic.  The egress PEs use this label to identify such BUM   traffic and, thus, apply DF filtering for All-Active multihomed   sites.  In absence of an unknown unicast traffic designation and in   the presence of enabling unknown unicast flooding, there can be   transient duplicate traffic to All-Active multihomed sites under the   following condition: the host MAC address is learned by the egress   PE(s) and advertised to the ingress PE; however, the MAC   Advertisement has not been received or processed by the ingress PE,   resulting in the host MAC address being unknown on the ingress PE but   known on the egress PE(s).  Therefore, when a packet destined to that   host MAC address arrives on the ingress PE, it floods it via ingress   replication to all the egress PE(s), and since they are known to the   egress PE(s), multiple copies are sent to the All-Active multihomed   site.  It should be noted that such transient packet duplication only   happens when a) the destination host is multihomed via All-Active   redundancy mode, b) flooding of unknown unicast is enabled in the   network, c) ingress replication is used, and d) traffic for the   destination host is arrived on the ingress PE before it learns the   host MAC address via BGP EVPN advertisement.  If it is desired to   avoid occurrence of such transient packet duplication (however low   probability that may be), then VXLAN-GPE encapsulation needs to be   used between these PEs and the ingress PE needs to set the BUM   Traffic Bit (B bit) [VXLAN-GPE] to indicate that this is an ingress-   replicated BUM traffic.Sajassi, et al.              Standards Track                   [Page 22]

RFC 8365         Network Virtualization Overlay Solution      March 20189.  Support for Multicast   The EVPN IMET route is used to discover the multicast tunnels among   the endpoints associated with a given EVI (e.g., given VNI) for VLAN-   Based Service and a given <EVI, VLAN> for VLAN-Aware Bundle Service.   All fields of this route are set as described inSection 5.1.3.  The   originating router's IP address field is set to the NVE's IP address.   This route is tagged with the PMSI Tunnel attribute, which is used to   encode the type of multicast tunnel to be used as well as the   multicast tunnel identifier.  The tunnel encapsulation is encoded by   adding the BGP Encapsulation Extended Community as perSection 5.1.1.   For example, the PMSI Tunnel attribute may indicate the multicast   tunnel is of type Protocol Independent Multicast - Sparse-Mode (PIM-   SM); whereas, the BGP Encapsulation Extended Community may indicate   the encapsulation for that tunnel is of type VXLAN.  The following   tunnel types as defined in [RFC6514] can be used in the PMSI Tunnel   attribute for VXLAN/NVGRE:         + 3 - PIM-SSM Tree         + 4 - PIM-SM Tree         + 5 - BIDIR-PIM Tree         + 6 - Ingress Replication   In case of VXLAN and NVGRE encapsulations with locally assigned VNIs,   just as in [RFC7432], each PE MUST advertise an IMET route to other   PEs in an EVPN instance for the multicast tunnel type that it uses   (i.e., ingress replication, PIM-SM, PIM-SSM, or BIDIR-PIM tunnel).   However, for globally assigned VNIs, each PE MUST advertise an IMET   route to other PEs in an EVPN instance for ingress replication or a   PIM-SSM tunnel, and they MAY advertise an IMET route for a PIM-SM or   BIDIR-PIM tunnel.  In case of a PIM-SM or BIDIR-PIM tunnel, no   information in the IMET route is needed by the PE to set up these   tunnels.   In the scenario where the multicast tunnel is a tree, both the   Inclusive as well as the Aggregate Inclusive variants may be used.   In the former case, a multicast tree is dedicated to a VNI.  Whereas,   in the latter, a multicast tree is shared among multiple VNIs.  For   VNI-Based Service, the Aggregate Inclusive mode is accomplished by   having the NVEs advertise multiple IMET routes with different RTs   (one per VNI) but with the same tunnel identifier encoded in the PMSI   Tunnel attribute.  For VNI-Aware Bundle Service, the Aggregate   Inclusive mode is accomplished by having the NVEs advertise multiple   IMET routes with different VNIs encoded in the Ethernet Tag field,   but with the same tunnel identifier encoded in the PMSI Tunnel   attribute.Sajassi, et al.              Standards Track                   [Page 23]

RFC 8365         Network Virtualization Overlay Solution      March 201810.  Data-Center Interconnections (DCIs)   For DCIs, the following two main scenarios are considered when   connecting data centers running evpn-overlay (as described here) over   an MPLS/IP core network:   -  Scenario 1: DCI using GWs   -  Scenario 2: DCI using ASBRs   The following two subsections describe the operations for each of   these scenarios.10.1.  DCI Using GWs   This is the typical scenario for interconnecting data centers over   WAN.  In this scenario, EVPN routes are terminated and processed in   each GW and MAC/IP route are always re-advertised from DC to WAN but   from WAN to DC, they are not re-advertised if unknown MAC addresses   (and default IP address) are utilized in the NVEs.  In this scenario,   each GW maintains a MAC-VRF (and/or IP-VRF) for each EVI.  The main   advantage of this approach is that NVEs do not need to maintain MAC   and IP addresses from any remote data centers when default IP routes   and unknown MAC routes are used; that is, they only need to maintain   routes that are local to their own DC.  When default IP routes and   unknown MAC routes are used, any unknown IP and MAC packets from NVEs   are forwarded to the GWs where all the VPN MAC and IP routes are   maintained.  This approach reduces the size of MAC-VRF and IP-VRF   significantly at NVEs.  Furthermore, it results in a faster   convergence time upon a link or NVE failure in a multihomed network   or device redundancy scenario, because the failure-related BGP routes   (such as mass withdrawal message) do not need to get propagated all   the way to the remote NVEs in the remote DCs.  This approach is   described in detail in Section 3.4 of [DCI-EVPN-OVERLAY].10.2.  DCI Using ASBRs   This approach can be considered as the opposite of the first   approach.  It favors simplification at DCI devices over NVEs such   that larger MAC-VRF (and IP-VRF) tables need to be maintained on   NVEs; whereas DCI devices don't need to maintain any MAC (and IP)   forwarding tables.  Furthermore, DCI devices do not need to terminate   and process routes related to multihoming but rather to relay these   messages for the establishment of an end-to-end Label Switched Path   (LSP).  In other words, DCI devices in this approach operate similar   to ASBRs for inter-AS Option B (seeSection 10 of [RFC4364]).  This   requires locally assigned VNIs to be used just like downstream-   assigned MPLS VPN labels where, for all practical purposes, the VNIsSajassi, et al.              Standards Track                   [Page 24]

RFC 8365         Network Virtualization Overlay Solution      March 2018   function like 24-bit VPN labels.  This approach is equally applicable   to data centers (or Carrier Ethernet networks) with MPLS   encapsulation.   In inter-AS Option B, when ASBR receives an EVPN route from its DC   over internal BGP (iBGP) and re-advertises it to other ASBRs, it   re-advertises the EVPN route by re-writing the BGP next hops to   itself, thus losing the identity of the PE that originated the   advertisement.  This rewrite of BGP next hop impacts the EVPN mass   withdrawal route (Ethernet A-D per ES) and its procedure adversely.   However, it does not impact the EVPN Aliasing mechanism/procedure   because when the Aliasing routes (Ethernet A-D per EVI) are   advertised, the receiving PE first resolves a MAC address for a given   EVI into its corresponding <ES, EVI>, and, subsequently, it resolves   the <ES, EVI> into multiple paths (and their associated next hops)   via which the <ES, EVI> is reachable.  Since Aliasing and MAC routes   are both advertised on a per-EVI-basis and they use the same RD and   RT (per EVI), the receiving PE can associate them together on a   per-BGP-path basis (e.g., per originating PE).  Thus, it can perform   recursive route resolution, e.g., a MAC is reachable via an <ES, EVI>   which in turn, is reachable via a set of BGP paths; thus, the MAC is   reachable via the set of BGP paths.  Due to the per-EVI basis, the   association of MAC routes and the corresponding Aliasing route is   fixed and determined by the same RD and RT; there is no ambiguity   when the BGP next hop for these routes is rewritten as these routes   pass through ASBRs.  That is, the receiving PE may receive multiple   Aliasing routes for the same EVI from a single next hop (a single   ASBR), and it can still create multiple paths toward that <ES, EVI>.   However, when the BGP next-hop address corresponding to the   originating PE is rewritten, the association between the mass   withdrawal route (Ethernet A-D per ES) and its corresponding MAC   routes cannot be made based on their RDs and RTs because the RD for   the mass Withdrawal route is different than the one for the MAC   routes.  Therefore, the functionality needed at the ASBRs and the   receiving PEs depends on whether the Mass Withdrawal route is   originated and whether there is a need to handle route resolution   ambiguity for this route.  The following two subsections describe the   functionality needed by the ASBRs and the receiving PEs depending on   whether the NVEs reside in a hypervisors or in ToR switches.10.2.1.  ASBR Functionality with Single-Homing NVEs   When NVEs reside in hypervisors as described inSection 7.1, there is   no multihoming; thus, there is no need for the originating NVE to   send Ethernet A-D per ES or Ethernet A-D per EVI routes.  However, as   noted inSection 7, in order to enable a single-homing ingress NVE to   take advantage of fast convergence, Aliasing, and Backup Path whenSajassi, et al.              Standards Track                   [Page 25]

RFC 8365         Network Virtualization Overlay Solution      March 2018   interacting with multihoming egress NVEs attached to a given ES, the   single-homing NVE should be able to receive and process Ethernet A-D   per ES and Ethernet A-D per EVI routes.  The handling of these routes   is described in the next section.10.2.2.  ASBR Functionality with Multihoming NVEs   When NVEs reside in ToR switches and operate in multihoming   redundancy mode, there is a need, as described inSection 8, for the   originating multihoming NVE to send Ethernet A-D per ES route(s)   (used for mass withdrawal) and Ethernet A-D per EVI routes (used for   Aliasing).  As described above, the rewrite of BGP next hop by ASBRs   creates ambiguities when Ethernet A-D per ES routes are received by   the remote NVE in a different ASBR because the receiving NVE cannot   associate that route with the MAC/IP routes of that ES advertised by   the same originating NVE.  This ambiguity inhibits the function of   mass withdrawal per ES by the receiving NVE in a different AS.   As an example, consider a scenario where a CE is multihomed to PE1   and PE2, where these PEs are connected via ASBR1 and then ASBR2 to   the remote PE3.  Furthermore, consider that PE1 receives M1 from CE1   but not PE2.  Therefore, PE1 advertises Ethernet A-D per ES1,   Ethernet A-D per EVI1, and M1; whereas, PE2 only advertises Ethernet   A-D per ES1 and Ethernet A-D per EVI1.  ASBR1 receives all these five   advertisements and passes them to ASBR2 (with itself as the BGP next   hop).  ASBR2, in turn, passes them to the remote PE3, with itself as   the BGP next hop.  PE3 receives these five routes where all of them   have the same BGP next hop (i.e., ASBR2).  Furthermore, the two   Ethernet A-D per ES routes received by PE3 have the same information,   i.e., same ESI and the same BGP next hop.  Although both of these   routes are maintained by the BGP process in PE3 (because they have   different RDs and, thus, are treated as different BGP routes),   information from only one of them is used in the L2 routing table (L2   RIB).                      PE1                     /   \                    CE     ASBR1---ASBR2---PE3                     \   /                      PE2                        Figure 3: Inter-AS Option B   Now, when the AC between the PE2 and the CE fails and PE2 sends   Network Layer Reachability Information (NLRI) withdrawal for Ethernet   A-D per ES route, and this withdrawal gets propagated and received by   the PE3, the BGP process in PE3 removes the corresponding BGP route;   however, it doesn't remove the associated information (namely ESI andSajassi, et al.              Standards Track                   [Page 26]

RFC 8365         Network Virtualization Overlay Solution      March 2018   BGP next hop) from the L2 routing table (L2 RIB) because it still has   the other Ethernet A-D per ES route (originated from PE1) with the   same information.  That is why the mass withdrawal mechanism does not   work when doing DCI with inter-AS Option B.  However, as described   previously, the Aliasing function works and so does "mass withdrawal   per EVI" (which is associated with withdrawing the EVPN route   associated with Aliasing, i.e., Ethernet A-D per EVI route).   In the above example, the PE3 receives two Aliasing routes with the   same BGP next hop (ASBR2) but different RDs.  One of the Aliasing   route has the same RD as the advertised MAC route (M1).  PE3 follows   the route resolution procedure specified in [RFC7432] upon receiving   the two Aliasing routes; that is, it resolves M1 to <ES, EVI1>, and,   subsequently, it resolves <ES, EVI1> to a BGP path list with two   paths along with the corresponding VNIs/MPLS labels (one associated   with PE1 and the other associated with PE2).  It should be noted that   even though both paths are advertised by the same BGP next hop   (ASRB2), the receiving PE3 can handle them properly.  Therefore, M1   is reachable via two paths.  This creates two end-to-end LSPs, from   PE3 to PE1 and from PE3 to PE2, for M1 such that when PE3 wants to   forward traffic destined to M1, it can load-balance between the two   LSPs.  Although route resolution for Aliasing routes with the same   BGP next hop is not explicitly mentioned in [RFC7432], this is the   expected operation; thus, it is elaborated here.   When the AC between the PE2 and the CE fails and PE2 sends NLRI   withdrawal for Ethernet A-D per EVI routes, and these withdrawals get   propagated and received by the PE3, the PE3 removes the Aliasing   route and updates the path list; that is, it removes the path   corresponding to the PE2.  Therefore, all the corresponding MAC   routes for that <ES, EVI> that point to that path list will now have   the updated path list with a single path associated with PE1.  This   action can be considered to be the mass withdrawal at the per-EVI   level.  The mass withdrawal at the per-EVI level has a longer   convergence time than the mass withdrawal at the per-ES level;   however, it is much faster than the convergence time when the   withdrawal is done on a per-MAC basis.   If a PE becomes detached from a given ES, then, in addition to   withdrawing its previously advertised Ethernet A-D per ES routes, it   MUST also withdraw its previously advertised Ethernet A-D per EVI   routes for that ES.  For a remote PE that is separated from the   withdrawing PE by one or more EVPN inter-AS Option B ASBRs, the   withdrawal of the Ethernet A-D per ES routes is not actionable.   However, a remote PE is able to correlate a previously advertised   Ethernet A-D per EVI route with any MAC/IP Advertisement routes also   advertised by the withdrawing PE for that <ES, EVI, BD>.  Hence, whenSajassi, et al.              Standards Track                   [Page 27]

RFC 8365         Network Virtualization Overlay Solution      March 2018   it receives the withdrawal of an Ethernet A-D per EVI route, it   SHOULD remove the withdrawing PE as a next hop for all MAC addresses   associated with that <ES, EVI, BD>.   In the previous example, when the AC between PE2 and the CE fails,   PE2 will withdraw its Ethernet A-D per ES and per EVI routes.  When   PE3 receives the withdrawal of an Ethernet A-D per EVI route, it   removes PE2 as a valid next hop for all MAC addresses associated with   the corresponding <ES, EVI, BD>.  Therefore, all the MAC next hops   for that <ES, EVI, BD> will now have a single next hop, viz. the LSP   to PE1.   In summary, it can be seen that Aliasing (and Backup Path)   functionality should work as is for inter-AS Option B without   requiring any additional functionality in ASBRs or PEs.  However, the   mass withdrawal functionality falls back from per-ES mode to per-EVI   mode for inter-AS Option B.  That is, PEs receiving a mass withdrawal   route from the same AS take action on Ethernet A-D per ES route;   whereas, PEs receiving mass withdrawal routes from different ASes   take action on the Ethernet A-D per EVI route.11.  Security Considerations   This document uses IP-based tunnel technologies to support data-plane   transport.  Consequently, the security considerations of those tunnel   technologies apply.  This document defines support for VXLAN   [RFC7348] and NVGRE encapsulations [RFC7637].  The security   considerations from those RFCs apply to the data-plane aspects of   this document.   As with [RFC5512], any modification of the information that is used   to form encapsulation headers, to choose a tunnel type, or to choose   a particular tunnel for a particular payload type may lead to user   data packets getting misrouted, misdelivered, and/or dropped.   More broadly, the security considerations for the transport of IP   reachability information using BGP are discussed in [RFC4271] and   [RFC4272] and are equally applicable for the extensions described in   this document.Sajassi, et al.              Standards Track                   [Page 28]

RFC 8365         Network Virtualization Overlay Solution      March 201812.  IANA Considerations   This document registers the following in the "BGP Tunnel   Encapsulation Attribute Tunnel Types" registry.   Value    Name   -----    ------------------------   8        VXLAN Encapsulation   9        NVGRE Encapsulation   10       MPLS Encapsulation   11       MPLS in GRE Encapsulation   12       VXLAN GPE Encapsulation13.  References13.1.  Normative References   [RFC2119]  Bradner, S., "Key words for use in RFCs to Indicate              Requirement Levels",BCP 14,RFC 2119,              DOI 10.17487/RFC2119, March 1997,              <https://www.rfc-editor.org/info/rfc2119>.   [RFC8174]  Leiba, B., "Ambiguity of Uppercase vs Lowercase inRFC2119 Key Words",BCP 14,RFC 8174, DOI 10.17487/RFC8174,              May 2017, <https://www.rfc-editor.org/info/rfc8174>.   [RFC7432]  Sajassi, A., Ed., Aggarwal, R., Bitar, N., Isaac, A.,              Uttaro, J., Drake, J., and W. Henderickx, "BGP MPLS-Based              Ethernet VPN",RFC 7432, DOI 10.17487/RFC7432, February              2015, <https://www.rfc-editor.org/info/rfc7432>.   [RFC7348]  Mahalingam, M., Dutt, D., Duda, K., Agarwal, P., Kreeger,              L., Sridhar, T., Bursell, M., and C. Wright, "Virtual              eXtensible Local Area Network (VXLAN): A Framework for              Overlaying Virtualized Layer 2 Networks over Layer 3              Networks",RFC 7348, DOI 10.17487/RFC7348, August 2014,              <https://www.rfc-editor.org/info/rfc7348>.   [RFC5512]  Mohapatra, P. and E. Rosen, "The BGP Encapsulation              Subsequent Address Family Identifier (SAFI) and the BGP              Tunnel Encapsulation Attribute",RFC 5512,              DOI 10.17487/RFC5512, April 2009,              <https://www.rfc-editor.org/info/rfc5512>.   [RFC4023]  Worster, T., Rekhter, Y., and E. Rosen, Ed.,              "Encapsulating MPLS in IP or Generic Routing Encapsulation              (GRE)",RFC 4023, DOI 10.17487/RFC4023, March 2005,              <https://www.rfc-editor.org/info/rfc4023>.Sajassi, et al.              Standards Track                   [Page 29]

RFC 8365         Network Virtualization Overlay Solution      March 2018   [RFC7637]  Garg, P., Ed. and Y. Wang, Ed., "NVGRE: Network              Virtualization Using Generic Routing Encapsulation",RFC 7637, DOI 10.17487/RFC7637, September 2015,              <https://www.rfc-editor.org/info/rfc7637>.13.2.  Informative References   [RFC7209]  Sajassi, A., Aggarwal, R., Uttaro, J., Bitar, N.,              Henderickx, W., and A. Isaac, "Requirements for Ethernet              VPN (EVPN)",RFC 7209, DOI 10.17487/RFC7209, May 2014,              <https://www.rfc-editor.org/info/rfc7209>.   [RFC4272]  Murphy, S., "BGP Security Vulnerabilities Analysis",RFC 4272, DOI 10.17487/RFC4272, January 2006,              <https://www.rfc-editor.org/info/rfc4272>.   [RFC7364]  Narten, T., Ed., Gray, E., Ed., Black, D., Fang, L.,              Kreeger, L., and M. Napierala, "Problem Statement:              Overlays for Network Virtualization",RFC 7364,              DOI 10.17487/RFC7364, October 2014,              <https://www.rfc-editor.org/info/rfc7364>.   [RFC7365]  Lasserre, M., Balus, F., Morin, T., Bitar, N., and Y.              Rekhter, "Framework for Data Center (DC) Network              Virtualization",RFC 7365, DOI 10.17487/RFC7365, October              2014, <https://www.rfc-editor.org/info/rfc7365>.   [RFC6514]  Aggarwal, R., Rosen, E., Morin, T., and Y. Rekhter, "BGP              Encodings and Procedures for Multicast in MPLS/BGP IP              VPNs",RFC 6514, DOI 10.17487/RFC6514, February 2012,              <https://www.rfc-editor.org/info/rfc6514>.   [RFC4271]  Rekhter, Y., Ed., Li, T., Ed., and S. Hares, Ed., "A              Border Gateway Protocol 4 (BGP-4)",RFC 4271,              DOI 10.17487/RFC4271, January 2006,              <https://www.rfc-editor.org/info/rfc4271>.   [RFC4364]  Rosen, E. and Y. Rekhter, "BGP/MPLS IP Virtual Private              Networks (VPNs)",RFC 4364, DOI 10.17487/RFC4364, February              2006, <https://www.rfc-editor.org/info/rfc4364>.   [TUNNEL-ENCAP]              Rosen, E., Ed., Patel, K., and G. Velde, "The BGP Tunnel              Encapsulation Attribute", Work in Progressdraft-ietf-idr-tunnel-encaps-09, February 2018.Sajassi, et al.              Standards Track                   [Page 30]

RFC 8365         Network Virtualization Overlay Solution      March 2018   [DCI-EVPN-OVERLAY]              Rabadan, J., Ed., Sathappan, S., Henderickx, W., Sajassi,              A., and J. Drake, "Interconnect Solution for EVPN Overlay              networks", Work in Progress,draft-ietf-bess-dci-evpn-overlay-10, March 2018.   [EVPN-GENEVE]              Boutros, S., Sajassi, A., Drake, J., and J. Rabadan, "EVPN              control plane for Geneve", Work in Progress,draft-boutros-bess-evpn-geneve-02, March 2018.   [VXLAN-GPE]              Maino, F., Kreeger, L., Ed., and U. Elzur, Ed., "Generic              Protocol Extension for VXLAN", Work in Progress,draft-ietf-nvo3-vxlan-gpe-05, October 2017.   [GENEVE]   Gross, J., Ed., Ganga, I., Ed., and T. Sridhar, Ed.,              "Geneve: Generic Network Virtualization Encapsulation",              Work in Progress,draft-ietf-nvo3-geneve-06, March 2018.   [IEEE.802.1Q]              IEEE, "IEEE Standard for Local and metropolitan area              networks - Bridges and Bridged Networks - Media Access              Control (MAC) Bridges and Virtual Bridged Local Area              Networks", IEEE Std 802.1Q.Sajassi, et al.              Standards Track                   [Page 31]

RFC 8365         Network Virtualization Overlay Solution      March 2018Acknowledgements   The authors would like to thank Aldrin Isaac, David Smith, John   Mullooly, Thomas Nadeau, Samir Thoria, and Jorge Rabadan for their   valuable comments and feedback.  The authors would also like to thank   Jakob Heitz for his contribution onSection 10.2.Contributors   S. Salam   K. Patel   D. Rao   S. Thoria   D. Cai   Cisco   Y. Rekhter   A. Issac   W. Lin   N. Sheth   Juniper   L. Yong   HuaweiSajassi, et al.              Standards Track                   [Page 32]

RFC 8365         Network Virtualization Overlay Solution      March 2018Authors' Addresses   Ali Sajassi (editor)   Cisco   United States of America   Email: sajassi@cisco.com   John Drake (editor)   Juniper Networks   United States of America   Email: jdrake@juniper.net   Nabil Bitar   Nokia   United States of America   Email: nabil.bitar@nokia.com   R. Shekhar   Juniper   United States of America   Email: rshekhar@juniper.net   James Uttaro   AT&T   United States of America   Email: uttaro@att.com   Wim Henderickx   Nokia   Copernicuslaan 50   2018 Antwerp   Belgium   Email: wim.henderickx@nokia.comSajassi, et al.              Standards Track                   [Page 33]