Movatterモバイル変換


[0]ホーム

URL:


[RFC Home] [TEXT|PDF|HTML] [Tracker] [IPR] [Info page]

PROPOSED STANDARD
Internet Engineering Task Force (IETF)                    P. Aitken, Ed.Request for Comments: 8038                                       BrocadeCategory: Standards Track                                      B. ClaiseISSN: 2070-1721                                      Cisco Systems, Inc.                                                                  S. B S                                                     Mojo Networks, Inc.                                                             C. McDowall                                                                 Brocade                                                        J. Schoenwaelder                                                Jacobs University Bremen                                                                May 2017Exporting MIB VariablesUsing the IP Flow Information Export (IPFIX) ProtocolAbstract   This document specifies a way to complement IP Flow Information   Export (IPFIX) Data Records with Management Information Base (MIB)   objects, avoiding the need to define new IPFIX Information Elements   for existing MIB objects that are already fully specified.   Two IPFIX Options Templates, as well as a method for creating IPFIX   Options Templates that are used to export the extra data required to   fully describe Simple Network Management Protocol (SNMP) MIB objects   in IPFIX, are specified herein.Status of This Memo   This is an Internet Standards Track document.   This document is a product of the Internet Engineering Task Force   (IETF).  It represents the consensus of the IETF community.  It has   received public review and has been approved for publication by the   Internet Engineering Steering Group (IESG).  Further information on   Internet Standards is available inSection 2 of RFC 7841.   Information about the current status of this document, any errata,   and how to provide feedback on it may be obtained athttp://www.rfc-editor.org/info/rfc8038.Aitken, et al.               Standards Track                    [Page 1]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017Copyright Notice   Copyright (c) 2017 IETF Trust and the persons identified as the   document authors.  All rights reserved.   This document is subject toBCP 78 and the IETF Trust's Legal   Provisions Relating to IETF Documents   (http://trustee.ietf.org/license-info) in effect on the date of   publication of this document.  Please review these documents   carefully, as they describe your rights and restrictions with respect   to this document.  Code Components extracted from this document must   include Simplified BSD License text as described in Section 4.e of   the Trust Legal Provisions and are provided without warranty as   described in the Simplified BSD License.Table of Contents1. Introduction ....................................................42. Motivation ......................................................53. Terminology .....................................................74. High-Level Solution Overview ....................................8   5. MIB Object Value Information Elements and the MIB Field      Options Template ...............................................105.1. MIB Field Options Architecture ............................115.2. IPFIX and MIB Data Model ..................................135.3. MIB Field Options - Specifications and Required Fields ....155.3.1. MIB Field Options Template .........................165.3.2. MIB Type Options Template ..........................165.4. MIB Field Options Template Formats ........................175.4.1. Data Template Containing a mibObjectValue Field ....175.4.2. MIB Field Options Template .........................195.4.3. MIB Field Options Data Records .....................20           5.4.4. Options Template Containing a                  mibObjectValue Field ...............................215.4.5. MIB Field Options Template with Semantics Fields ...23           5.4.6. MIB Field Options Template with Extra MIB                  Object Details .....................................245.5. Use of Field Order in the MIB Field Options Template ......275.6. Identifying the SNMP Context ..............................275.7. Template Management .......................................285.7.1. Large Messages .....................................285.7.2. Template Withdrawal and Reuse ......................29Aitken, et al.               Standards Track                    [Page 2]

RFC 8038           Exporting MIB Variables with IPFIX           May 20175.8. Exporting Conceptual Rows and Tables ......................295.8.1. Exporting Conceptual Rows - Indexing ...............305.8.2. Exporting Conceptual Rows - mibObjectValueRow ......305.8.3. Exporting Conceptual Rows - AUGMENTS ...............365.8.4. Exporting Conceptual Tables - mibObjectValueTable ..37           5.8.5. Exporting Columnar Objects: Using                  mibIndexIndicator ..................................386. Example Use Cases ..............................................396.1. Non-columnar MIB Object: Established TCP Connections ......39      6.2. Enterprise-Specific MIB Object: Detailing CPU Load           History ...................................................426.3. Exporting a Conceptual Row: The OSPF Neighbor Row .........45      6.4. Exporting Augmented Conceptual Row: Mapping IF-MIB           ID to Name ................................................496.5. Exporting a Columnar Object: ipIfStatsInForwDatagrams .....55      6.6. Exporting a Columnar Object Indexed by Information           Elements: ifOutQLen .......................................58      6.7. Exporting with Multiple Contexts: The OSPF           Neighbor Row Revisited ....................................627. Configuration Considerations ...................................658. The Collecting Process's Side ..................................669. Applicability ..................................................6610. Security Considerations .......................................6711. IANA Considerations ...........................................6811.1. New IPFIX Semantics ......................................6811.1.1. snmpCounter .......................................6811.1.2. snmpGauge .........................................6811.2. New IPFIX Information Elements ...........................6911.2.1. New MIB Object Value Information Elements .........6911.2.2. New MIB Field Options Information Elements ........7511.2.3. New MIB Type Information Elements .................7912. References ....................................................8112.1. Normative References .....................................8112.2. Informative References ...................................82   Acknowledgments ...................................................84   Authors' Addresses ................................................84Aitken, et al.               Standards Track                    [Page 3]

RFC 8038           Exporting MIB Variables with IPFIX           May 20171.  Introduction   There is growing interest in using IP Flow Information Export (IPFIX)   as a push mechanism for exporting management information.  Using a   push protocol such as IPFIX instead of a polling protocol like SNMP   is especially interesting in situations where large chunks of   repetitive data need to be exported periodically.   While initially targeted at different problems, there is a large   parallel between the information transported via IPFIX and SNMP.   Furthermore, certain Management Information Base (MIB) objects are   highly relevant to Flows as they are understood today.  For example,   in the IPFIX Information Model [IANA-IPFIX], Information Elements   coming from the SNMP world have already been specified, e.g.,   ingressInterface and egressInterface both refer to the ifIndex object   as defined in [RFC2863].   In particular, the Management Information Base was designed as a   separate system of definitions; this opens up the possibility of   exporting objects defined via the MIB over other protocols.   Rather than mapping existing MIB objects to IPFIX Information   Elements on a case-by-case basis, it would be advantageous to enable   the export of any existing or future MIB objects as part of an IPFIX   Data Record.  This way, the duplication of Data Models [RFC3444],   both as SMIv2 MIB objects and IPFIX Information Elements, out of the   same Information Model [RFC3444] would be avoided.   Therefore, the primary goals of this document are:   o  to specify a way to complement IPFIX Data Records with MIB      objects;   o  to avoid the need to define new IPFIX Information Elements for      existing MIB objects that are already fully specified;   o  to allow the correlation of SNMP and IPFIX sourced data by      exporting them together; and   o  to allow SNMP push data from SNMP-only devices to be more easily      integrated into IPFIX-based collection infrastructures.Aitken, et al.               Standards Track                    [Page 4]

RFC 8038           Exporting MIB Variables with IPFIX           May 20172.  Motivation   The intended scope of this work is the addition of MIB variable(s) to   IPFIX Information Elements in Data Records, in order to complement   the Data Records with useful and already-standardized information.   Special consideration is given to the case of an existing   Template Record that needs to be augmented with some MIB variables   whose index is already present in the Template Record as an IPFIX   Information Element -- for example, a 7-tuple Data Record containing   the ingressInterface Information Element, which needs to be augmented   by interface counters [RFC2863] that are indexed by the respective   ingressInterface values already contained in the Data Records.  SeeSection 3 for terminology definitions.   Many Data Records contain the ingressInterface and/or the   egressInterface Information Elements.  These Information Elements   carry an ifIndex value, a MIB object defined in [RFC2863].  In order   to retrieve additional information about the identified interface, a   Collector could simply poll relevant objects from the device running   the Exporter via SNMP.  However, that approach has several problems:   o  It requires implementing a mediation function between two Data      Models, i.e., MIB objects and IPFIX Information Elements.   o  Confirming the validity of simple mappings (e.g., ifIndex to      ifName) requires either checking on a regular basis that the      Exporter's network management system did not reload or imposing      ifIndex persistence across an Exporter's reload.   o  Synchronization problems occur because counters carried in      Data Records and counters carried in SNMP messages are retrieved      from the Exporter at different points in time and thus cannot be      correlated.  In the best case, assuming very tight integration of      an IPFIX Collector with an SNMP polling engine, SNMP data is      retrieved shortly after Data Records have been received, which      implies a delay of the sum of the active or idle timeouts (if not      null) plus the time to export the Data Record to the Collector.      If, however, the SNMP data is retrieved by a generic Network      Management Station (NMS) polling interface statistics, then the      time lag between IPFIX counters and SNMP counters can be      significantly higher.  See [RFC5102] for details regarding active      and idle timeouts.   This document does not specify how to carry SNMP notifications in   IPFIX, even if the specifications in this document could potentially   allow this.Aitken, et al.               Standards Track                    [Page 5]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017   Since IPFIX is a push mechanism, initiated from the Exporter with no   acknowledgment method, this specification does not provide the   ability to execute configuration changes.   The Distributed Management Expression MIB [RFC2982], which is a   mechanism to create new MIB variables based on the content of   existing ones, could also be advantageous in the context of this   specification.  Indeed, newly created MIB objects (for example, the   link utilization MIB variable), created with the Distributed   Management Expression MIB [RFC2982], could nicely complement   Data Records.   Another advantage of exporting MIB objects via IPFIX is that IPFIX   would benefit from an extended series of types to be exported.  The   simple and application-wide data types specified in SMIv2 [RFC2578],   along with new textual conventions, can be exported within IPFIX and   then decoded in the Collector.  However, since a textual convention   can contain almost any name, this document does not extend the   existing "IPFIX Information Elements" subregistry [IANA-IPFIX] that   contains informationElementDataType.   The overall architectural model is depicted in Figure 1.  The IPFIX   Exporter accesses the device's instrumentation, which follows the   specifications contained in MIB modules.  Other management   interfaces, such as the Network Configuration Protocol (NETCONF) or   the device's Command Line Interface (CLI), may provide access to the   same instrumentation.                +------+  +-------+  +.........+  +.....+                | SNMP |  | IPFIX |  : NETCONF :  : CLI :                +------+  +-------+  +.........+  +.....+                    |         |           |          |              +--------------------------------------------+              | Instrumentation (specified in MIB modules) |              +--------------------------------------------+                       Figure 1: Architectural ModelAitken, et al.               Standards Track                    [Page 6]

RFC 8038           Exporting MIB Variables with IPFIX           May 20173.  Terminology   IPFIX-specific terminology (Information Element, Template,   Template Record, Options Template Record, Template Set, Collector,   Exporter, Data Record, Transport Session, Exporting Process,   Collecting Process, etc.) used in this document is defined inSection 2 of [RFC7011].  As in [RFC7011], these IPFIX-specific terms   have the first letter of a word capitalized.   This document prefers the more generic term "Data Record" (as opposed   to "Flow Record") in relation to the export of MIB objects.   Object Identifier (MIB OID)      An Object Identifier value is an ordered list of non-negative      numbers.  For SMIv2, each number in the list is referred to as a      sub-identifier.  There are at most 128 sub-identifiers in a value,      and each sub-identifier has a maximum value of 2^32 - 1      (4294967295 decimal).  See[RFC2578], Section 3.5.   MIB Object Identifier Information Element      An IPFIX Information Element ("mibObjectIdentifier") that denotes      that a MIB Object Identifier (MIB OID) is exported in the      (Options) Data Record.  SeeSection 11.2.2.1.   SMIv2 Terminology      The key words "MIB module", "MIB object", "INDEX", "AUGMENTS",      "textual convention", "columnar object", "conceptual row", and      "conceptual table" in this document are to be interpreted as      described in SMIv2 [RFC2578].   SMIv2 SYNTAX      The SYNTAX key words "INTEGER", "Integer32", "OCTET STRING",      "OBJECT IDENTIFIER", "BITS", "IpAddress", "Counter32", "Gauge32",      "TimeTicks", "Opaque", "Counter64", "Unsigned32", "SEQUENCE", and      "SEQUENCE OF" in this document are to be interpreted as described      in SMIv2 [RFC2578].   SNMP Context Terminology      The key words "snmpEngineID", "contextEngineID", and "contextName"      in this document are to be interpreted as described in [RFC3411].Aitken, et al.               Standards Track                    [Page 7]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017   mibObjectValue Information Elements      "mibObjectValue Information Elements" refers to any and all of the      mibObjectValue Information Elements generically.  Any restriction      or requirement in this document that refers to "mibObjectValue"      applies to the following Information Elements as defined inSection 11.2.1: mibObjectValueInteger, mibObjectValueOctetString,      mibObjectValueOID, mibObjectValueBits, mibObjectValueIPAddress,      mibObjectValueCounter, mibObjectValueGauge,      mibObjectValueTimeTicks, mibObjectValueUnsigned,      mibObjectValueTable, and mibObjectValueRow.   Abstract Data Type      Abstract Data Types for IPFIX are defined inSection 3.1 of      [RFC7012].  This specification uses the Abstract Data Types      "unsigned8", "unsigned32", "unsigned64", "signed32", "octetArray",      "string", "ipv4Address", and "subTemplateList".   IE      Used as shorthand for "Information Element" [RFC7011] in the      figures.   The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",   "SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and   "OPTIONAL" in this document are to be interpreted as described in   [RFC2119].4.  High-Level Solution Overview   This document specifies a method for creating IPFIX Options Templates   that are used to export the extra data required to describe MIB   variables (seeSection 5.1).   This allows IPFIX Templates to contain any combination of fields   defined by traditional IPFIX Information Element(s) and/or MIB Object   Identifier(s).  The MIB Object Identifiers can reference either   non-columnar or columnar MIB object(s).  Enterprise-specific MIB   Object Identifiers are also supported.   This document also defines two standard IPFIX Options Templates (seeSection 5.3) that are used as part of the mechanism to export MIB   object metadata:   o  MIB Field Options Template (Section 5.3.1)   o  MIB Type Options Template (Section 5.3.2)Aitken, et al.               Standards Track                    [Page 8]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017   This document defines three classes of new IPFIX Information   Elements.  These are used to export values from the MIB, export   required Object Identifier information, and optionally export type   data from a MIB module:   o  MIB Object Value Information Elements (Section 11.2.1)   o  MIB Field Options Information Elements (Section 11.2.2)   o  MIB Type Information Elements (Section 11.2.3)   Additionally, this document defines two new IPFIX semantics that are   required for the new Information Elements:   o  snmpCounter (Section 11.1.1)   o  snmpGauge (Section 11.1.2)   Two common types defined in SMIv2 are conceptual rows and conceptual   tables.  It is desirable that exporting a complete or partial   conceptual row be simple and efficient.  This is accomplished by   using IPFIX Structured Data [RFC6313] to reduce repetition of Object   Identifier and indexing data.   To allow the use of individual columnar objects that make up a   conceptual row, a method is also specified to explain that a MIB   object is indexed by other fields in the same Data Flow.  For an   individually indexed mibObjectValue, the index fields are sent in the   same way as any of the other fields in the same Data Record and may   be mibObjectValue Information Element(s) or other existing   Information Element(s).   Also, in some cases Exporters may not want (or be able) to export the   full information on how the MIB objects being exported are indexed.   This may be because the MIB object is being used purely as type   information or the Exporting Process may not have knowledge of the   indexing required.  Therefore, providing index information for   columnar objects is optional.Aitken, et al.               Standards Track                    [Page 9]

RFC 8038           Exporting MIB Variables with IPFIX           May 20175.  MIB Object Value Information Elements and the MIB Field Options    Template   This document defines new mibObjectValue Information Elements (inSection 11.2.1).  These are used to export MIB objects as part of   standard IPFIX Templates.  The mibObjectValue Information Elements   contain the actual data values.   The Metering Process or Exporting Process may extract the data values   for mibObjectValue Information Elements from a Process that resides   on the same device or may capture or create the data required to   match the definition of the MIB object.  In particular, exporting a   value of a MIB object defined in a certain MIB module does not imply   that the SNMP process on the device supports that MIB module.   The main issue that arises from exporting values of MIB objects in   IPFIX is that MIB Object Identifiers do not fit into the standard   IPFIX Template format [RFC7011], as this only provides a 16-bit   Information Element identifier.   The values of a MIB object could be exported using a MIB-specific   Information Element, without providing any Object Identifiers.   However, without exporting the actual MIB OID, the full type of the   data would be unknown, and every field containing MIB object data   would appear identical.  Without knowing which OID the contents of a   field map to, the data would be incomprehensible to a Collector.   For the values in the mibObjectValue Information Elements to be   understandable, more meta-information about the mibObjectValue   Information Elements must be sent as part of the IPFIX export.  The   required minimum information to understand each field that is being   exported is provided inSection 5.3.1.   One approach to this problem would be to extend the IPFIX standard to   allow extended Field Specifiers so that metadata about fields can be   included in Data Templates.  This would, however, require a new   version of the IPFIX standard that may not be backward compatible.   However, future versions of IPFIX may export the required MIB   metadata as part of newly defined IPFIX Set versions.   This document defines a MIB Field Options Template to export the   extra meta-information required for mibObjectValue Information   Elements.  This is a standard IPFIX Options Template Set that   includes a minimum set of required fields (seeSection 5.3.1) and may   include extra fields to provide more meta-information about one of   the mibObjectValue Information Elements.Aitken, et al.               Standards Track                   [Page 10]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017   The MIB Field Options export tells the Collecting Process the OID for   the MIB object type definition for the following (Template, field).5.1.  MIB Field Options Architecture   Four IPFIX Sets are used together to export a Flow that contains   mibObjectValue Information Elements.  These are:   1.  A Template Set that includes the mibObjectValue Information       Element.          The Template Set informs the Collector that a MIB object value          of length N will be exported.  This Set may also be an Options          Template Set.   2.  A MIB Field Options Template Set.          The MIB Field Options Template describes which metadata will          be sent for each mibObjectValue Information Element being          exported.   3.  A MIB Field Options Data Set.          The MIB Field Options Data Set includes the metadata for each          MIB object (i.e., the mibObjectIdentifier or          mibSubIdentifier).  The metadata about the mibObjectValue          Information Elements only needs to be resent as per normal          Template refreshes or resends.   4.  A Data Set.          The Data Set contains only the actual data extracted from the          MIB or described by the MIB module.Aitken, et al.               Standards Track                   [Page 11]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017   Figure 2 shows the IPFIX Message structure for a MIB field in a   Template Set.         +-------------------------------------------------------+         | IPFIX Message Header                                  |         +-------------------------------------------------------+         | Template Set         (A)                              |         +-------------------------------------------------------+         | Options Template Set (B) (MIB Field Options Template) |         +-------------------------------------------------------+         | Data Set             (B) (MIB Field Options Data)     |         +-------------------------------------------------------+         | Data Set             (A)                              |         +-------------------------------------------------------+    Figure 2: IPFIX Message Structure for a MIB Field in a Template Set   The MIB Field Options Template defines MIB Field Options   Data Records.  The MIB Field Options Data Records annotate the Data   Template with mibObjectValue metadata.  Together, the Data Template   and MIB Field Options Data Records define the Data Records that will   be exported.   The Data Records (A) have a dependency on the two Templates and the   MIB Field Options Data Records.   More Data Sets that use the same mibObjectValue Information Element   can then be sent in subsequent packets.Aitken, et al.               Standards Track                   [Page 12]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017   Figure 3 shows the relationships between the Sets discussed above.                                        +------------------------------+                                        |MIB Field Options Template (B)|                                        +------------------------------+                                        |(templateId, elementIndex)    |                                        +------------------------------+                                        |        mibOID                |                                        +------------------------------+                                                     |                                                     | Defines                                                     V    +------------------------+              +--------------------------+    |    Data Template (A)   |              |MIB Field Options Data (B)|    +------------------------+              +--------------------------+    |Field 0 - regular IE    |              |                          |    +------------------------+              +--------------------------+    |Field 1-mibObjectValue  | <----------- | (X,1) = OID              |    +------------------------+   Annotates  +--------------------------+    |Field 2-mibObjectValue  | <----------- | (X,2) = OID              |    +------------------------+              +--------------------------+                |                                    |                |------------------------------------/                |                | Defines                |                V    +------------------------+    |    Data Records (A)    |    |------------------------|    | Field 0 data           |    +------------------------+    | Field 1 data           |    +------------------------+    | Field 2 data           |    +------------------------+                   Figure 3: Relationships between Sets5.2.  IPFIX and MIB Data Model[RFC2578], Section 7.1 specifies that the SYNTAX clause for a MIB   object defines the abstract data structure of an object and what it   must contain:   "The data structure must be one of the following: a base type, BITS,   or a textual convention.  (SEQUENCE OF and SEQUENCE are also possible   for conceptual tables, seesection 7.1.12)."Aitken, et al.               Standards Track                   [Page 13]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017   For each of the SYNTAX clause options, this document specifies   exactly which mibObjectValue Information Element to use.   If a MIB object to be exported is a textual convention, the   definition of the textual convention must be consulted and the SYNTAX   clause used to determine the correct base type.  This may recurse if   the textual convention is defined in terms of another textual   convention, but this should end at a base type.   If the SYNTAX clause contains a textual convention or sub-typing   (e.g., integerSubType, octetStringSubType) [RFC2578], the   mibObjectSyntax Information Element SHOULD be used to export this   detail to the Collecting Process.   The options for the SYNTAX clause are then mapped as follows:   +-------------+-------------------+---------------------------------+   | Section in  | SYNTAX            | mibObjectValue Information      |   |RFC 2578    |                   | Element                         |   +-------------+-------------------+---------------------------------+   | 7.1.1       | INTEGER/Integer32 | mibObjectValueInteger           |   | 7.1.2       | OCTET STRING      | mibObjectValueOctetString       |   | 7.1.3       | OBJECT IDENTIFIER | mibObjectValueOID               |   | 7.1.4       | BITS              | mibObjectValueBits              |   | 7.1.5       | IpAddress         | mibObjectValueIPAddress         |   | 7.1.6       | Counter32         | mibObjectValueCounter           |   | 7.1.7       | Gauge32           | mibObjectValueGauge             |   | 7.1.8       | TimeTicks         | mibObjectValueTimeTicks         |   | 7.1.9       | Opaque            | mibObjectValueOctetString       |   | 7.1.10      | Counter64         | mibObjectValueCounter           |   | 7.1.11      | Unsigned32        | mibObjectValueUnsigned          |   | 7.1.12      | SEQUENCE          | mibObjectValueRow               |   | 7.1.12      | SEQUENCE OF       | mibObjectValueTable             |   +-------------+-------------------+---------------------------------+               Table 1: SMIv2 SYNTAX to mibObjectValue Types   Values are encoded as per the standard IPFIX encoding of Abstract   Data Types.  The only new encoding reference in this document is that   Object Identifiers (OIDs) will be encoded as per ASN.1/BER [X.690] in   an octetArray.   The mibObjectValue and mibObjectIdentifier Information Elements are   standard IPFIX fields.  Therefore, the E bit of the mibObjectValue or   mibObjectIdentifier Information Elements is set to 0.Aitken, et al.               Standards Track                   [Page 14]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017   The MIB object being exported may be defined in an enterprise-   specific MIB module, but the Information Elements defined in this   standard are still exported with the E bit set to 0.  The OID being   exported indicates that the MIB object was defined in an   enterprise-specific MIB module.5.3.  MIB Field Options - Specifications and Required Fields   For each mibObjectValue Information Element that is defined in an   IPFIX Template, a MIB Field Options Data Record will be exported that   provides the required minimum information to define the MIB object   that is being exported (seeSection 5.3.1).   The MIB Field Options Data Records are defined in a Template referred   to in this document as a MIB Field Options Template with the format   specified inSection 5.4.   The MIB Field Options Template and MIB Field Options Data Records   MUST be exported in the same IPFIX Message as any Template that is   using a mibObjectValue Information Element.  Note that this places an   implicit size constraint on the export.   This whole set of Templates and MIB Field Options Data Records MUST   all be exported prior to the corresponding Data Records that depend   upon them.  That is, the export order MUST be:   1.  Data Template for mibObjectValue Information Elements (Set ID 2)   2.  MIB Field Options Template (Set ID 3)   3.  MIB Field Options Data Records (Set ID >= 256)   4.  MIB Object Value Data Records (Set ID >= 256)   Note that the ID of an identical MIB Field Options Template that has   already been exported MAY be reused without exporting the Template   again.   IPFIX Set IDs are defined inSection 3.3.2 of [RFC7011].  A value of   2 indicates a Template Set, a value of 3 indicates an Options   Template Set, and values 256 and above indicate Data Sets.Aitken, et al.               Standards Track                   [Page 15]

RFC 8038           Exporting MIB Variables with IPFIX           May 20175.3.1.  MIB Field Options Template   Three fields are REQUIRED to unambiguously export a standalone   mibObjectValue Information Element with a MIB Field Options Template:   o  (scope) templateId [IANA-IPFIX]   o  (scope) informationElementIndex [IANA-IPFIX]   o  mibObjectIdentifier (Section 11.2.2.1) or mibSubIdentifier      (Section 11.2.2.2)   These are the minimum fields required in a MIB Field Options Template   (seeSection 5.4.2).   The mibObjectIdentifier is used to provide the OID for all   mibObjectValue Information Elements exported, except when IPFIX   Structured Data [RFC6313] is being used to export a conceptual row   (seeSection 5.8.2).   While the following are optional, they are nevertheless RECOMMENDED   in certain circumstances, as described in the referenced sections:   o  mibCaptureTimeSemantics      (discussed inSection 5.4.5; Information Element defined inSection 11.2.2.4)   o  mibIndexIndicator      (discussed inSection 5.8.5; Information Element defined inSection 11.2.2.3)   o  mibContextEngineID      (discussed inSection 5.6; Information Element defined inSection 11.2.2.5)   o  mibContextName      (discussed inSection 5.6; Information Element defined inSection 11.2.2.6)5.3.2.  MIB Type Options Template   There are also fields that provide type information from a MIB object   definition that MAY be exported to a Collecting Process.   Type information is statically defined in a MIB module; it is not   expected to change.  However, the additional information about the   MIB object may help a Collecting Process that does not have access to   the MIB module.Aitken, et al.               Standards Track                   [Page 16]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017   To export a MIB Type Options Template, the mibObjectIdentifier is   RECOMMENDED as a Scope Field so that it matches the MIB Field Options   Template.  Any combination of the other MIB Type fields may be   included.   o  (scope) mibObjectIdentifier (seeSection 11.2.2.1)   o  mibObjectName (seeSection 11.2.3.1)   o  mibObjectDescription (seeSection 11.2.3.2)   o  mibObjectSyntax (seeSection 11.2.3.3)   o  mibModuleName (seeSection 11.2.3.4)5.4.  MIB Field Options Template Formats5.4.1.  Data Template Containing a mibObjectValue Field   The Template Record format of a Template that uses a mibObjectValue   Information Element is identical to the standard IPFIX format as   defined in [RFC7011], so a field using a mibObjectValue Information   Element is specified using standard IPFIX Field Specifiers per   [RFC7011].   The only extra requirement on a Template Record using one or more   mibObjectValue Information Elements is that it MUST export the   required metadata specified inSection 5.3.1 for EACH mibObjectValue   Information Element.   If multiple MIB Field Options Data Records that refer to a   mibObjectValue are received, the latest MUST be used.  This matches   the expected behavior of IPFIX Templates.   There is a one-to-one mapping between each mibObjectValue Information   Element and a MIB Field Options Data Record.   A MIB Field Options Template and corresponding Data Record MUST be   exported to provide the minimum required metadata.Aitken, et al.               Standards Track                   [Page 17]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017   Figure 4 shows an IPFIX Template Set using a mibObjectValue   Information Element.      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 2           |          Length = 16          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID             |         Field Count = 2       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |0| IE = Existing IPFIX Field   |        Field Length           |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |0| IE = <mibObjectValue>       |        Field Length (MIB)     |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+   Figure 4: IPFIX Template Set Using mibObjectValue Information Element   Where:      <mibObjectValue>         One of the mibObjectValue IPFIX Information Elements that         denotes that MIB object data (i.e., the value of a MIB object)         will be exported in the (Options) Data Record.         This could be any one of the mibObjectValue Information         Elements defined inSection 11.2.1: mibObjectValueInteger,         mibObjectValueOctetString, mibObjectValueOID,         mibObjectValueBits, mibObjectValueIPAddress,         mibObjectValueCounter, mibObjectValueGauge,         mibObjectValueTimeTicks, mibObjectValueUnsigned,         mibObjectValueTable, and mibObjectValueRow.         When a mibObjectValue Information Element is used, the MIB         Object Identifier ("mibObjectIdentifier") MUST be exported via         a MIB Field Options Template and MIB Field Options Data Record.         SeeSection 5.3.1.      Field Length (MIB)         The length of the encoded MIB object data in the corresponding         Data Records, in octets.  See [RFC7011] for a detailed         definition.  Note that the Field Length can be expressed using         reduced-size encoding per [RFC7011].  Note that the Field         Length may be encoded using variable-length encoding per         [RFC7011].Aitken, et al.               Standards Track                   [Page 18]

RFC 8038           Exporting MIB Variables with IPFIX           May 20175.4.2.  MIB Field Options Template   The MIB Field Options Template is a standard Options Template that   defines the fields that will be exported to provide enough metadata   about a mibObjectValue Information Element so that the Collector can   tie the data values in the mibObjectValue Information Element back to   the definition of the MIB object.   All MIB Field Options Templates contain the fields specified inSection 5.3.1.   Figure 5 shows the required fields to export a mibObjectIdentifier   for the MIB Field Options Template format.      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 3           |          Length = 22          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID             |        Field Count = 3        |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |   Scope Field Count = 2       |0| IE = templateId             |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 2       |0| IE = informationElementIndex|     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 2       |0| IE = mibObjectIdentifier    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 65535   |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+       Figure 5: MIB Field Options Template Format - Required Fields   Where:      templateId         The first Scope Field is an IPFIX Information Element that         denotes that a Template Identifier will be exported as part of         the MIB Field Options Data Record.  This Template Identifier,         paired with an index into that Template (the         "informationElementIndex" field), uniquely references one         mibObjectValue Information Element being exported.Aitken, et al.               Standards Track                   [Page 19]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017      informationElementIndex         The second Scope Field is an IPFIX Information Element that         denotes a zero-based index into the fields defined by a         Template.  When paired with a "templateId", this uniquely         references one mibObjectValue Information Element being         exported.      mibObjectIdentifier         An IPFIX Information Element that denotes the MIB Object         Identifier for the mibObjectValue Information Element exported         in the (Options) Template Record.         When a MIB Object Value Information Element is used, the MIB         Object Identifier MUST be specified in the MIB Field Options         Template Record or specified by other means.         The Object Identifier is encoded in the IPFIX Data Record in         ASN.1/BER [X.690] format.         Variable-length encoding SHOULD be used with the         mibObjectIdentifier so that multiple MIB OIDs of different         lengths can be exported efficiently.  This will also allow         reuse of the MIB Field Options Template.         Variable-length encoding is indicated by the Field Length value         of 65535, per Sections3.2 and7 of [RFC7011].  The RECOMMENDED         use of variable-length encoding for mibObjectIdentifier fields         is indicated in subsequent figures by placing 65535 in the         relevant length fields.5.4.3.  MIB Field Options Data Records   The MIB Field Options Data Records conform to the Template   Specification in the MIB Field Options Template.  There may be   multiple MIB Field Options Data Records exported.   The Collecting Process MUST store all received MIB Field Options Data   information for the duration of each Transport Session, because the   Collecting Process will need to refer to the extra meta-information   to fully decode each mibObjectValue Information Element.Aitken, et al.               Standards Track                   [Page 20]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017   Figure 6 shows the format of the exported MIB Field Options   Data Record, detailing the metadata that will be exported to match   the Template in Figure 5.      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID               |          Length = N           |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        templateId             |  informationElementIndex      |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |   VLEN        |                  mibObjectIdentifier ...      |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        ... mibObjectIdentifier (continued) ...                |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        templateId             |  informationElementIndex      |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |    VLEN       |  mibObjectIdentifier  ...                     |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        ... mibObjectIdentifier (continued) ...                |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+             Figure 6: Format of MIB Field Options Data Record   VLEN contains the variable length of the mibObjectIdentifier perSection 7 of [RFC7011].5.4.4.  Options Template Containing a mibObjectValue Field   The Options Template Record format of a Template that uses a   mibObjectValue Information Element is identical to the standard   format as defined in [RFC7011].  The mibObjectValue Information   Element is specified using standard Field Specifiers per [RFC7011].   A mibObjectValue Information Element can be either a Scope Field or a   non-Scope Field in an Options Template Record.   The only extra requirement on an Options Template Record using one or   more mibObjectValue Information Elements is that it MUST export the   required metadata specified inSection 5.3.1 for EACH mibObjectValue   Information Element.   An IPFIX Options Template Record MUST export a MIB Field Options   Template and Data Record to provide the minimum required metadata for   each mibObjectValue Information Element.Aitken, et al.               Standards Track                   [Page 21]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017   Figure 7 shows an IPFIX Options Template Set using an existing IPFIX   field as a Scope Field and with a mibObjectValueInteger Information   Element as a non-Scope Field, while Figure 8 shows an IPFIX Options   Template Set using a mibObjectValueInteger Information Element as a   Scope Field with an existing IPFIX field as a non-Scope Field.      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 3           |          Length = 18          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID             |         Field Count = 2       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |      Scope Field Count = 1    |0| IE = Existing IPFIX Field   |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length           |0| IE = mibObjectValueInteger  |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length           |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+          Figure 7: IPFIX Options Template Set Using a Non-Scope                        mibObjectValueInteger Field      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 3           |          Length = 18          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID             |         Field Count = 2       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |      Scope Field Count = 1    |0| IE = mibObjectValueInteger  |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length           |0| IE = Existing IPFIX Field   |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length           |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+            Figure 8: IPFIX Options Template Set Using a Scope                        mibObjectValueInteger FieldAitken, et al.               Standards Track                   [Page 22]

RFC 8038           Exporting MIB Variables with IPFIX           May 20175.4.5.  MIB Field Options Template with Semantics Fields   A MIB Field Options Template MAY specify that extra Information   Elements will be exported to record how the mibObjectValue was   collected.   Alternatively, one of the existing IPFIX observationTime* elements   [IANA-IPFIX] may be exported to specify exactly when the value was   collected.   Figure 9 shows the MIB Field Options Template for a non-columnar   field with Semantic Data.      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 3           |          Length = 26          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID             |        Field Count = 4        |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |   Scope Field Count = 2       |0| IE = templateId             |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 2       |0| IE = informationElementIndex|     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 2       |0| IE = mibObjectIdentifier    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 65535   |0| IE = mibCaptureTimeSemantics|     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 1       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+       Figure 9: MIB Field Options Template for a Non-columnar Field                            with Semantic Data   Where:      mibObjectIdentifier         Note the use of variable-length encoding for this field.      mibCaptureTimeSemantics         The MIB Capture Time Semantics IPFIX Information Element, as         defined inSection 11.2.2.4.         It is RECOMMENDED to include this field when exporting a         mibObjectValue Information Element that specifies counters or         statistics, particularly for situations with long-lived Flows.Aitken, et al.               Standards Track                   [Page 23]

RFC 8038           Exporting MIB Variables with IPFIX           May 20175.4.6.  MIB Field Options Template with Extra MIB Object Details   The OID exported within the mibObjectIdentifier IPFIX Information   Element provides an OID reference to a MIB object type definition   that will fully describe the MIB object data being exported.   However, an Exporting Process MAY decide to include some extra fields   to more fully describe the MIB object that is being exported with a   mibObjectValue Information Element.   This can be helpful if the Collecting Process may not have access to   the MIB module.   The Exporting Process can either include the fields with extra object   details as part of the MIB Field Options Template or export a   separate Options Template and a Data Record that maps MIB OIDs in   mibObjectIdentifier fields to the object details.   If only a few fields are being exported, then including extra type   data in the MIB Field Options export will be more efficient.Aitken, et al.               Standards Track                   [Page 24]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017   The MIB Field Options Template for a non-columnar field with extra   MIB object details is shown in Figure 10.      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 3           |          Length = 38          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID             |        Field Count = 7        |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |   Scope Field Count = 2       |0| IE = templateId             |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 2       |0| IE = informationElementIndex|     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 2       |0| IE = mibObjectIdentifier    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 65535   |0| IE = mibObjectSyntax        |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 65535   |0| IE = mibObjectName          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 65535   |0| IE = mibObjectDescription   |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 65535   |0| IE = mibModuleName          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 65535   |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+      Figure 10: MIB Field Options Template for a Non-columnar Field                       with Extra MIB Object Details   Where:      mibObjectSyntax         The MIB object syntax string as defined inSection 11.2.3.3.         Note that a separate mibObjectSyntax Information Element is         required (rather than extend the existing "IPFIX Information         Elements" subregistry [IANA-IPFIX] that contains         informationElementDataType) because the SYNTAX clause could         contain almost any name.      mibObjectName         The textual name of a mibObjectIdentifier object.Aitken, et al.               Standards Track                   [Page 25]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017      mibObjectDescription         The textual description for a mibObjectIdentifier.      mibModuleName         The textual name of the MIB module that defines a MIB object.      Note the use of variable-length encoding for the      mibObjectIdentifier, mibObjectSyntax, mibObjectName,      mibObjectDescription, and mibModuleName, since these are all      string fields.   The MIB details can be exported in Data Records specified using a   regular IPFIX Options Template Record [RFC7011], as shown in   Figure 11.  This may be more efficient, as the bulk of this data is   text based and SHOULD be exported only once to the Collecting Process   if there are many MIB objects being exported.  This prevents this   large textual data from being included for every use of a   mibObjectValue Information Element.      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 3           |          Length = 30          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID             |        Field Count = 5        |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |   Scope Field Count = 1       |0| IE = mibObjectIdentifier    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 65535   |0| IE = mibObjectSyntax        |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 65535   |0| IE = mibObjectName          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 65535   |0| IE = mibObjectDescription   |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 65535   |0| IE = mibModuleName          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 65535   |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+      Figure 11: Alternative mibObjectIdentifier Options Template Set                            with Object DetailsAitken, et al.               Standards Track                   [Page 26]

RFC 8038           Exporting MIB Variables with IPFIX           May 20175.5.  Use of Field Order in the MIB Field Options Template   The MIB Field Options Template export makes use of the   informationElementIndex [IANA-IPFIX] to specify which field in the   Template the metadata relates to; this avoids any ordering   constraints on the Data Template.  The mibObjectValue Information   Elements in an IPFIX export can be in any order in the export packet.   However, fields used as an INDEX MUST be in the same order as the   order specified in the INDEX clause of the conceptual row MIB object.   The informationElementIndex specifies which field in the Template   extra information is being provided for.   This is analogous to standard IPFIX Template Sets, which also specify   the order of the fields and provide their type and size.   If the Template changes such that the order is different, then the   MIB Field Options Data MUST be resent to reflect the new ordering.  A   new Template ID MUST be used to reflect that the ordering has   changed.  Older MIB Field Options Data may refer to the incorrect   field.   A templateId [IANA-IPFIX] is only locally unique within a combination   of an Observation Domain and Transport Session.  As such, each MIB   Field Options Data Record can only refer to templateIds within the   same Observation Domain and session.5.6.  Identifying the SNMP Context   Each MIB OID is looked up in a specific context, usually the default   context.  If exporting a MIB OID value that isn't in the default   context, then the context MUST be identified by including the   mibContextEngineID (seeSection 11.2.2.5) and mibContextName (seeSection 11.2.2.6) fields in the MIB Field Options Template and   associated MIB Field Options Data Records, or be included in the same   Template as the mibObjectValue field.   This context data MUST be included for each field that is not in the   default context.   The context information MAY be exported as part of the Template that   includes the mibObjectValue Information Element, or the context   information MAY be exported in the MIB Field Options Data Record that   refers to the field.  Context fields exported in the same Template   MUST take precedence over those that refer to the Template.  Context   fields MUST apply to all mibObjectValue Information Elements in the   same Template, and there MUST NOT be duplicates of mibContextName or   mibContextEngineID in a Template.Aitken, et al.               Standards Track                   [Page 27]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017   So, a MIB Field Options Template MAY specify no context information,   just the context engine ID or both the context engine and context   name.  This allows the Exporter to export the bulk of data in the   default context and only tag those items that are required.   Since the MIB Field Options Template applies for all the Data Records   of a Template, using context fields in the MIB Field Options Data   Template requires that each mibContextEngineID / mibContextName pair   have its own Template.5.7.  Template Management   Templates are managed as perSection 8 of [RFC7011], with the   additional constraint that the MIB Field Options Template and MIB   Field Options Data Records MUST be exported in the same IPFIX Message   as any (Options) Template Record that uses a mibObjectValue   Information Element.   When exporting over a Stream Control Transmission Protocol (SCTP)   transport [RFC4960], the MIB Field Options Data Records MUST be   exported reliably and in the same SCTP stream as their associated   Templates per [RFC6526].   If a Template using a mibObjectValue Information Element is resent   for any reason, the Data Records it depends on MUST be sent as well.   If a Template is replaced with a new (Options) Template, then a new   MIB Field Options Data Record MUST be sent with the replacement   referencing the new Template ID.   An Exporting Process SHOULD reuse MIB Field Options Template IDs when   the Templates are identical.  Each (Options) Template Record MUST   still be accompanied by a copy of the MIB Field Options Template.5.7.1.  Large Messages   The requirement to export the MIB Field Options Template and MIB   Field Options Data Records in the same IPFIX Message as any (Options)   Template Record that uses a mibObjectValue Information Element may   result in very large IPFIX Messages.   In environments with restricted Message sizes, and only when a   reliable SCTP transport is being used, the MIB Field Options   Template, MIB Field Options Data, Data Template, and Data Records MAY   be exported in separate Messages in the same SCTP stream, provided   that their order is maintained.Aitken, et al.               Standards Track                   [Page 28]

RFC 8038           Exporting MIB Variables with IPFIX           May 20175.7.2.  Template Withdrawal and Reuse   Data Records containing mibObjectValue Information Elements MUST NOT   be exported if their corresponding Data Template or MIB Field Options   Template has been withdrawn, since the MIB Field Options Template   MUST be exported in the same IPFIX Message as the Data Template that   it annotates, except as allowed by the caveat mentioned inSection 5.7.1.   MIB Field Options Template IDs MUST NOT be reused while they are   required by any existing Data Templates.5.8.  Exporting Conceptual Rows and Tables   There are three approaches for an IPFIX Exporting Process to export   the values of columnar objects:   1.  Ignoring the indexing of columnar objects   2.  Exporting conceptual rows / table objects using IPFIX Structured       Data [RFC6313]   3.  Exporting individual indexed columnar objects   Firstly, a subordinate columnar object may be used purely as a data   type.  In this case, there is no index information or relation to a   conceptual row object provided by the Exporting Process.   Secondly, mibObjectValueRow or mibObjectValueTable can be used to   export partial or complete conceptual rows, using IPFIX Structured   Data [RFC6313].   Thirdly, in a mixed option/data IPFIX/MIB Template, the   mibObjectValue Information Element can have the values of the INDEX   clause of the conceptual row provided by other fields in the   Data Record.  In this case, each mibObjectValue Information Element   must specify which other field(s) in the Template is providing the   index information.Aitken, et al.               Standards Track                   [Page 29]

RFC 8038           Exporting MIB Variables with IPFIX           May 20175.8.1.  Exporting Conceptual Rows - Indexing   This document defines two forms of indexing that can be used for   conceptual row MIB objects:   Indexing based on IPFIX Structured Data [RFC6313] is used solely by   the mibObjectValueRow Information Element.  Each conceptual row of   the MIB object corresponds to a single Data Record exported.  The   index fields defined in the INDEX clause of the MIB object MUST all   be present in the same order as the Scope Fields.  This allows a   simple table export of a conceptual row MIB object without any extra   fields required to indicate which fields make up the conceptual row   INDEX.   Field-based indexing is used by giving each mibObjectValue   Information Element a mibIndexIndicator to flag the required index   fields.  This allows complex indexing or mixing of existing IPFIX   Information Elements with MIB fields, with minimum overhead.  It also   allows multiple columnar MIB objects from different conceptual rows   to be exported with complete indexing in one IPFIX Template.5.8.2.  Exporting Conceptual Rows - mibObjectValueRow   The simplest approach to exporting a complete or partial conceptual   row object is done with the mibObjectValueRow Information Element.   This is an IPFIX Structured Data subTemplateList Information Element   as detailed in [RFC6313].  The Template specified MUST be an Options   Template.  It also MUST have the fields specified in the INDEX clause   of the conceptual row object as the Scope Fields in the MIB Field   Options Template and Data Set.   An overview of this architecture is given in Figure 12.  This shows   that the full MIB object type definition OID is exported for the   mibObjectValueRow conceptual row field but that the individual   columnar objects only require the sub-identifier to be exported.  To   make the diagram clearer, the Templates for the MIB Field Options   Templates are not shown.Aitken, et al.               Standards Track                   [Page 30]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017        +---------------------------+    +------------------------+        | Data Template             |    | MIB Field Options Data |        |                           |    |                        |        | mibObjectValueRow         |<---| OID                    |        +---------------------------+    +------------------------+          |          | +-----------------------+    +------------------------+          | | Options Template      |    | MIB Field Options Data |          | |                       |    |                        |          | | Scope mibObjectValue* |<---| mibSubIdentifier       |          | |       mibObjectValue* |<---| mibSubIdentifier       |          | +-----------------------+    +------------------------+          |             |          V             V        +---------------------------+        | Data Flows                |        |                           |        | subTemplateList (1 entry) |        +---------------------------+           Figure 12: Architecture for Exporting Conceptual Rows                          with mibObjectValueRow   The mibIndexIndicator is not required for each individual   mibObjectValue Information Element, as mibObjectValueRow provides a   structure that includes the index details.   When indexing based on IPFIX Structured Data [RFC6313] is used, all   Scope Fields MUST be the INDEX objects in the same order as defined   in the INDEX clause of the conceptual row being exported.   Each conceptual table MIB object has two related OIDs.  There is an   OID that refers to the table with the syntax of SEQUENCE OF and an   OID that refers to each entry or conceptual row with the syntax of   SEQUENCE.  The OID for the SEQUENCE of a conceptual row MUST be   exported.   For example, in the IF-MIB [RFC2863], the OID for ifEntry should be   exported rather than the OID for ifTable.  The OID for the table (in   this case, ifTable) can be derived by removing one sub-identifier   from the ifEntry OID.   The full OID for the conceptual row MIB object type definition being   exported with the mibObjectValueRow Information Element MUST be   exported.  However, the fields that are members of the conceptual row   need not have the full OID of their MIB object type definition   exported.  Instead, the mibSubIdentifier Information Element can be   used to document which entry in the conceptual row the field is.Aitken, et al.               Standards Track                   [Page 31]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017   In this case, the exported Flow will contain a single complete or   partial row from a table inside a single field of the Data Record.   There may be MIB objects that are specified in the INDEX of the   conceptual row but not columnar objects of the same conceptual row;   for these, the Exporter MUST provide the full OID in a   mibObjectIdentifier field.   So, for a conceptual row object with the OID "1.2.3.4.5.6" the OID of   the type definitions for columnar objects "1.2.3.4.5.6.1"   "1.2.3.4.5.6.2" can be exported with just a mibSubIdentifier of "1"   and "2", respectively.   The mibObjectValue Information Elements exported using the   mibObjectValueRow export MUST all either be objects defined in the   INDEX clause, columnar objects of the same conceptual row object, or   columnar objects that augment the same conceptual row.   The IPFIX Structured Data [RFC6313] subTemplateList format requires   the Structured Data Type Semantics to be specified.  Unless there is   a more appropriate option in the "IPFIX Structured Data Types   Semantics" subregistry [IANA-IPFIX], the "undefined" Structured Data   Type Semantics can be used.   Figure 13 shows an IPFIX Template for an IPFIX Structured Data   [RFC6313] export of a conceptual row, while Figure 14 shows an IPFIX   Options Template for a complete conceptual row with five columns and   two index fields.  Figure 15 shows the MIB Field Options Template for   a conceptual row field.  Figure 16 shows the MIB Field Options   Template for the columns inside the conceptual row.  Figure 17 shows   the OID Data for the conceptual row that will be exported.      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 2           |          Length = 12          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID = 300       |         Field Count = 1       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |0| IE = mibObjectValueRow      |         Field Length          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+              Figure 13: IPFIX Template for a Conceptual RowAitken, et al.               Standards Track                   [Page 32]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 3           |          Length = 30          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID = 301       |         Field Count = 5       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |      Scope Field Count = 2    |0| IE = mibObjectValue INDEX1  |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length           |0| IE = mibObjectValue INDEX2  |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length           |0| IE = mibObjectValue COLUMN3 |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length           |0| IE = mibObjectValue COLUMN4 |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length           |0| IE = mibObjectValue COLUMN5 |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length           |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+         Figure 14: IPFIX Options Template for a mibObjectValueRow                  with Five Columns and Two Index Fields      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 3           |          Length = 22          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID = 302       |        Field Count = 3        |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |   Scope Field Count = 2       |0| IE = templateId             |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 2       |0| IE = informationElementIndex|     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 2       |0| IE = mibObjectIdentifier    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 65535   |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     Figure 15: MIB Field Options Template for a Conceptual Row ObjectAitken, et al.               Standards Track                   [Page 33]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017   Where:      templateId         The templateId for the MIB option that will be exported.      mibObjectIdentifier         The MIB OID for the conceptual row that is being exported.         Note the use of variable-length encoding for this field.      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 3           |          Length = 22          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID = 303       |        Field Count = 3        |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |   Scope Field Count = 2       |0| IE = templateId             |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 2       |0| IE = informationElementIndex|     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 2       |0| IE = mibSubIdentifier       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 2       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+        Figure 16: MIB Field Options Template for Columnar Objects                           of a Conceptual Table   Where:      templateId         The templateId used will be for the Template referred to in the         subTemplateList of the mibObjectValueRow that will be exported.      mibSubIdentifier         The sub-identifier that specifies the columnar object's ID         within the conceptual row.Aitken, et al.               Standards Track                   [Page 34]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 302         |          Length = N           |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID = 300       |  informationElementIndex      |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |   VLEN        |                  mibObjectIdentifier ...      |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        ... mibObjectIdentifier (continued) ...                |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 303         |          Length = N           |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        templateId = 301       |  informationElementIndex      |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |  mibSubIdentifier             |        templateId = 301       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |  informationElementIndex      |  mibSubIdentifier             |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        templateId = 301       |  informationElementIndex      |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |  mibSubIdentifier             |        templateId = 301       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |  informationElementIndex      |  mibSubIdentifier             |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        templateId = 301       |  informationElementIndex      |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |  mibSubIdentifier             |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+          Figure 17: mibOption Data Record for the Conceptual Row   Where:      mibObjectIdentifier         Will contain the OID for the conceptual row as a whole.      mibSubIdentifier         The mibSubIdentifier fields will contain the extra         sub-identifier that, when added to the OID for the conceptual         row, gives the full OID for the object.Aitken, et al.               Standards Track                   [Page 35]

RFC 8038           Exporting MIB Variables with IPFIX           May 20175.8.3.  Exporting Conceptual Rows - AUGMENTS   SMIv2 defines conceptual rows as having either an INDEX clause or an   AUGMENTS clause.  Conceptual row definitions with an AUGMENTS clause   extend an existing base conceptual row with an INDEX clause.  It is   not possible in SMIv2 to augment a conceptual row that itself has an   AUGMENTS clause.  The base table and the augmentation have an   identical INDEX.   Since augmentations allow adding extra columns to existing tables, it   is beneficial to be able to support them easily in IPFIX exports of   conceptual rows.   The mibObjectValueRow OID MAY refer to either the base table with the   INDEX clause or a conceptual row with an AUGMENTS clause.  The   mibSubIdentifier in any MIB Field Options Data Record MUST always   refer to the OID exported for the mibObjectValueRow Information   Element.   If the mibObjectValueRow OID refers to a base table, then any extra   columns from conceptual rows with an AUGMENTS clause MUST have their   full OID exported.   If the mibObjectValueRow OID refers to a conceptual row that augments   another conceptual row using the AUGMENTS clause, then any MIB fields   from the original table's INDEX or columnar objects MUST NOT use the   mibSubIdentifier and MUST instead export the full OID in a   mibObjectIdentifier.   If the mibObjectValueRow refers to an augmenting conceptual row, the   Scope Fields of the Template used in the subTemplateList MUST have   the index fields from the base table, in the same order as its scope.   This is identical to the Scope Field requirements for conceptual rows   with an INDEX clause.   This flexibility is provided so that the conceptual rows with the   most columns can be exported using the more efficient   mibSubIdentifier.  For example, exporting a complete set of   augmentation columns would only require the full OIDs for the MIB   objects in the INDEX.   It is possible to export MIB object columns from multiple augmenting   conceptual rows.  If this is done, then the base table SHOULD be used   as the main OID for the mibObjectValueRow.Aitken, et al.               Standards Track                   [Page 36]

RFC 8038           Exporting MIB Variables with IPFIX           May 20175.8.4.  Exporting Conceptual Tables - mibObjectValueTable   Multiple rows of a conceptual table can be exported in the   mibObjectValueTable Information Element (Section 11.2.1.10).  This   allows a set of conceptual rows corresponding to a conceptual table   to be exported as a single field.  Therefore, a complete set of rows   can be exported as a single field with other Information Elements in   a Template.  In this fashion, several complete conceptual tables   could be exported in one packet.   As also specified for mibObjectValueRow (Section 5.8.2), the more   specific (i.e., full) OID of the SEQUENCE entity MUST be exported.   The format of mibObjectValueTable is identical to mibObjectValueRow,   except that the length of the subTemplateList may be zero or more   entries.   All the other, i.e., non-length, requirements for mibObjectValueRow   inSection 5.8.2 apply to mibObjectValueTable.   An overview of this architecture is given in Figure 18.  This   architecture is similar to the architecture shown in Figure 12.        +---------------------------+    +------------------------+        | Data Template             |    | MIB Field Options Data |        |                           |    |                        |        | mibObjectValueTable       |<---| OID                    |        +---------------------------+    +------------------------+          |          | +-----------------------+    +------------------------+          | | Options Template      |    | MIB Field Options Data |          | |                       |    |                        |          | | Scope mibObjectValue* |<---| mibSubIdentifier       |          | |       mibObjectValue* |<---| mibSubIdentifier       |          | +-----------------------+    +------------------------+          |             |          V             V        +-----------------------------+        | Data Flows                  |        |                             |        | subTemplateList (n entries) |        |    row 1                    |        |    ...                      |        |    row n                    |        +-----------------------------+          Figure 18: Architecture for Exporting Conceptual Tables                         with mibObjectValueTableAitken, et al.               Standards Track                   [Page 37]

RFC 8038           Exporting MIB Variables with IPFIX           May 20175.8.5.  Exporting Columnar Objects: Using mibIndexIndicator   The other option for indexing a columnar object that is part of a   conceptual table is explicit indexing.  In this case, the Options   Template Set scope may contain either non-index fields or columnar   MIB objects from multiple conceptual rows being exported.  In this   case, each mibObjectValue Information Element requires the   mibIndexIndicator with the bits set for the fields that are used to   index that individual columnar object.   The index fields MUST be in the "correct" order as defined in the   conceptual row that each columnar object is a member of.   If a mibObjectValue Information Element that is being indexed using   mibIndexIndicator is being used as an Options Template Scope Field,   then all fields used to index that field MUST also be Scope Fields.   Figure 19 shows the MIB Field Options Template for an indexed MIB   columnar object.      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 3           |          Length = 26          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID             |        Field Count = 4        |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |   Scope Field Count = 2       |0| IE = templateId             |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 2       |0| IE = informationElementIndex|     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 2       |0| IE = mibIndexIndicator      |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 2       |0| IE = mibObjectIdentifier    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 65535   |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+           Figure 19: MIB Field Options Template for an Indexed                            MIB Columnar ObjectAitken, et al.               Standards Track                   [Page 38]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017   Where:      mibIndexIndicator         The MIB Index Indicator IPFIX Information Element that marks         which fields in the Data Record will act as INDEX values for         the exported MIB object.         The index data for a mibObjectValue will be other fields         contained in the same Data Record.  The mibIndexIndicator marks         the fields whose value(s) should be added to the OID for the         MIB object type definition exported in mibObjectIdentifier to         get the OID for the instance of the MIB object.         Elements used to index MIB objects MUST be exported in the same         order as they are specified in the index field of the         conceptual table they belong to.      mibObjectIdentifier         Note the use of variable-length encoding for this field.6.  Example Use Cases6.1.  Non-columnar MIB Object: Established TCP Connections   The number of established TCP connections of a remote network device   could be monitored by configuring it to periodically export the   number of established TCP connections to a centralized Collector.  In   this example, the Exporter would export an IPFIX Message every   30 minutes that contained Data Records detailing the number of   established TCP connections.   The table of data that is to be exported looks like:            +-------------------------+-----------------------+            |        TIMESTAMP        | ESTABLISHED TCP CONN. |            +-------------------------+-----------------------+            | StartTime +   0 seconds |           10          |            | StartTime +  60 seconds |           14          |            | StartTime + 120 seconds |           19          |            | StartTime + 180 seconds |           16          |            | StartTime + 240 seconds |           23          |            | StartTime + 300 seconds |           29          |            +-------------------------+-----------------------+                   Table 2: Established TCP ConnectionsAitken, et al.               Standards Track                   [Page 39]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017   The Template Record for such a Data Record will provide details for   the following two Information Elements:   1.  flowStartSeconds from [IANA-IPFIX], Information Element 150: The       absolute timestamp of the first packet of this Flow.   2.  tcpCurrEstab from [RFC4022], Object ID "1.3.6.1.2.1.6.9": The       number of TCP connections for which the current state is either       ESTABLISHED or CLOSE-WAIT.   Figure 20 shows the exported Template Set detailing the   Template Record for exporting the number of established TCP   connections.      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 2           |          Length = 16          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID = 400       |        Field Count = 2        |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |0|   IE = flowStartSeconds     |        Field Length = 4       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |0|   IE = mibObjectValueGauge  |        Field Length = 4       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+              Figure 20: Example of tcpCurrEstab Template SetAitken, et al.               Standards Track                   [Page 40]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017   Figure 21 shows the exported MIB Field Options Template Set detailing   the metadata that will be exported about the mibObjectValueGauge   Information Element in Template 400 in Template Record.      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 3           |          Length = 22          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID = 401       |        Field Count = 3        |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |  Scope Field Count = 2        |0| IE = templateId             |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 2       |0| IE = informationElementIndex|     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 2       |0| IE = mibObjectIdentifier    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 65535   |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     Figure 21: Example of tcpCurrEstab MIB Field Options Template Set   Figure 22 shows the exported MIB Field Options Data Set detailing the   metadata that will be exported about the mibObjectValueGauge   Information Element in Template 400 in Template Record.   The OID for the MIB object tcpCurrEstab from [RFC4022], Object ID   "1.3.6.1.2.1.6.9", will be encoded in ASN.1/BER [X.690] as   "06072B060102010609" in the Data Record, which takes 9 octets.      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 401         |          Length = 18          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID = 400       | informationElementIndex = 1   |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |   VLEN = 9    | mibObjectIdentifier ...                       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       ... mibObjectIdentifier = "1.3.6.1.2.1.6.9" ...         |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |   ... 06072B060102010609 ...  |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+       Figure 22: Example of tcpCurrEstab MIB Field Options Data SetAitken, et al.               Standards Track                   [Page 41]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017   Figure 23 shows the start of the Data Set for exporting the number of   established TCP connections (seeSection 6.1).      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 400         |          Length = 52          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                    StartTime +   0 seconds                    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                              10                               |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                    StartTime +  60 seconds                    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                              14                               |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                    StartTime + 120 seconds                    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                              19                               |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                    StartTime + 180 seconds                    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                              16                               |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                    StartTime + 240 seconds                    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                              23                               |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                    StartTime + 300 seconds                    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                              29                               |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+                Figure 23: Example of tcpCurrEstab Data Set6.2.  Enterprise-Specific MIB Object: Detailing CPU Load History   For the sake of demonstration, an enterprise-specific MIB object from   the CISCO-PROCESS-MIB [CISCO-PROCESS-MIB] is chosen.  This example   would be valid with any enterprise-specific MIB module.   The CPU usage of a remote network device with one CPU could be   monitored by configuring it to periodically export CPU usage   information, i.e., the cpmCPUTotal1minRev from the proprietary   CISCO-PROCESS-MIB, Object ID "1.3.6.1.4.1.9.9.109.1.1.1.1.7", to a   centralized Collector.Aitken, et al.               Standards Track                   [Page 42]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017   Although the cpmCPUTotal1minRev MIB object is a columnar object in a   conceptual row, if there is only one CPU no extra information is   conveyed by providing the index field.  So, in this case, it is   acceptable to not export the cpmCPUTotalIndex MIB object.  If there   were multiple CPUs, it would be appropriate to include the   cpmCPUTotalIndex field and specify the relationship.   In this example, the Exporter would export an IPFIX Message every   30 minutes that contained Data Records detailing the CPU 1-minute   busy average at 1-minute intervals.   The table of data that is to be exported looks like:             +-------------------------+---------------------+             |        TIMESTAMP        | CPU BUSY PERCENTAGE |             +-------------------------+---------------------+             | StartTime +   0 seconds |         10%         |             | StartTime +  60 seconds |         14%         |             | StartTime + 120 seconds |         19%         |             | StartTime + 180 seconds |         16%         |             | StartTime + 240 seconds |         23%         |             | StartTime + 300 seconds |         29%         |             +-------------------------+---------------------+                          Table 3: CPU Usage Data   The Template Record for such a Data Record will provide details for   the following two Information Elements:   1.  flowStartSeconds from [IANA-IPFIX], Information Element 150: The       absolute timestamp of the first packet of this Flow.   2.  A mibObjectValueGauge for cpmCPUTotal1minRev, the overall CPU       busy percentage in the last 1-minute period.Aitken, et al.               Standards Track                   [Page 43]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017   Figure 24 shows the exported Template Set detailing the   Template Record for exporting CPU Load (seeSection 6.2).      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 2           |          Length = 16          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID = 402       |        Field Count = 2        |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |0|   IE = flowStartSeconds     |        Field Length = 4       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |0|   IE = mibObjectValueGauge  |        Field Length = 1       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+                Figure 24: Example of CPU Load Template Set   Figure 25 shows the exported Template Set detailing the MIB Field   Options Template for exporting CPU Load (seeSection 6.2).  Note:   This is identical to the MIB Field Options Template given in   Figure 21, so the same Template could have been reused.      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 3           |          Length = 22          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID = 403       |        Field Count = 3        |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |   Scope Field Count = 2       |0| IE = templateId             |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 2       |0| IE = informationElementIndex|     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 2       |0| IE = mibObjectIdentifier    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 65535   |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+       Figure 25: Example of CPU Load MIB Field Options Template Set   Figure 26 shows the exported MIB Field Options Data Set detailing the   metadata that will be exported about the mibObjectValueGauge   Information Element in Template 402 in Template Record (seeSection 6.2).   The OID for the cpmCPUTotal1minRev has been encoded using ASN.1/BER   to "060D2B0601040109096D0101010107" at 15 octets long.Aitken, et al.               Standards Track                   [Page 44]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 403         |          Length = 24          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID = 402       | informationElementIndex = 1   |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |   VLEN = 15   |  mibObjectIdentifier                     ...  |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |              "1.3.6.1.4.1.9.9.109.1.1.1.1.7"             ...  |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |               060D2B0601040109096D0101010107             ...  |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                                                          ...  |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+         Figure 26: Example of CPU Load MIB Field Options Data Set   Note that although cpmCPUTotal1minRev is 32 bits long, reduced-size   encoding [RFC7011] has been used to encode it within a single octet.   The encoding size was specified by setting the length for the   mibObjectValueGauge field to 1 octet in the main Data Template; see   Figure 24.   This example stresses that, even though the OID cpmCPUTotal1minRev is   enterprise-specific, the E bit for the mibObjectValueGauge and   mibObjectIdentifier is set to 0, because the mibObjectValueGauge and   mibObjectIdentifier Information Elements are not enterprise-specific.   That this data is from an Enterprise MIB is included in the OID that   includes an Enterprise ID.   The corresponding Data Set does not add any value for this example   and is therefore not displayed.6.3.  Exporting a Conceptual Row: The OSPF Neighbor Row   Many conceptual tables are already defined in standard and   proprietary MIBs.  These can be exported with a minimum of overhead   by using the mibObjectValueRow.  This allows the Exporting Process to   unambiguously define the INDEX for the entire conceptual row as the   Scope Fields of an Options Template Set.  The use of a MIB Field   Options Template with mibSubIdentifier being used means that each   individual columnar object does not need to have its OID exported to   the Collector.Aitken, et al.               Standards Track                   [Page 45]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017   The ospfNbrTable, defined in the OSPF MIB [RFC4750], consists of   ospfNbrEntry, which has the OID "1.3.6.1.2.1.14.10.1".  Each   mibObjectValueRow Data Record will therefore correspond to an   ospfNbrEntry.   The following fields will be exported:   +------------------+----------------+-------------------------+-----+   | Object           | ID             | mibObjectValue          | Len |   +------------------+----------------+-------------------------+-----+   | ospfNbrIpAddr    | ospfNbrEntry 1 | mibObjectValueIPAddress |  4  |   | ospfNbrAddress-  | ospfNbrEntry 2 | mibObjectValueInteger   |  4  |   | -LessIndex       |                |                         |     |   | ospfNbrRtrId     | ospfNbrEntry 3 | mibObjectValueIPAddress |  4  |   | ospfNbrState     | ospfNbrEntry 6 | mibObjectValueInteger   |  1  |   +------------------+----------------+-------------------------+-----+                   Table 4: OSPF Neighbor Entry Objects   The OIDs that will be used to export this table are shown in Table 5.    +------------------+-----------------------+---------------------+    | Entity           | Full OID              | Exported as         |    +------------------+-----------------------+---------------------+    | ospfNbrEntry     | 1.3.6.1.2.1.14.10.1   | 1.3.6.1.2.1.14.10.1 |    | ospfNbrIpAddr    | 1.3.6.1.2.1.14.10.1.1 | 1                   |    | ospfNbrAddress-  | 1.3.6.1.2.1.14.10.1.2 | 2                   |    | -LessIndex       |                       |                     |    | ospfNbrRtrId     | 1.3.6.1.2.1.14.10.1.3 | 3                   |    | ospfNbrState     | 1.3.6.1.2.1.14.10.1.6 | 6                   |    +------------------+-----------------------+---------------------+                            Table 5: OSPF OIDs   Figure 27 shows the Templates exported to support the   mibObjectValueRow.  Figure 28 shows the example OID Data for the   conceptual row exported in mibObjectValueRow.  Figure 29 shows the   example data export for a few neighbors in the table; Figure 29 also   shows a Data Record formatted as per IPFIX Structured Data [RFC6313]   and using the "undefined" (= 0xFF) semantic from the "IPFIX   Structured Data Types Semantics" subregistry [IANA-IPFIX].  Note that   the OID for ospfNbrEntry has been encoded using ASN.1/BER to   "06082B060102010E0A01" at 10 octets long.Aitken, et al.               Standards Track                   [Page 46]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 2           |          Length = 12          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID = 500       |         Field Count = 1       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |0| IE = mibObjectValueRow      |         Field Length = 16     |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 3           |          Length = 26          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID = 501       |        Field Count = 4        |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |   Scope Field Count = 2       |0| IE = mibObjectValueIPAddress|     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 4       |0| IE = mibObjectValueInteger  |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 4       |0| IE = mibObjectValueIPAddress|     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 4       |0| IE = mibObjectValueInteger  |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 1       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+                                     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+                                     |       Set ID = 3              |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Length = 22          |      Template ID = 502        |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Count = 3        |  Scope Field Count = 2        |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |0| IE = templateId             |        Field Length = 2       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |0| IE = informationElementIndex|        Field Length = 2       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |0| IE = mibObjectIdentifier    |        Field Length = 65535   |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+Aitken, et al.               Standards Track                   [Page 47]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 3           |          Length = 22          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID = 503       |        Field Count = 3        |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |   Scope Field Count = 2       |0| IE = templateId             |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 2       |0| IE = informationElementIndex|     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 2       |0| IE = mibSubIdentifier       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 2       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+   Figure 27: Example of ospfNbrEntry Template and Options Template Sets      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 502         |          Length = 20          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID = 500       | informationElementIndex = 0   |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |   VLEN = 10   | mibObjectIdentifier = "1.3.6.1.2.1.14.10.1"   |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                  06082B060102010E0A01                         |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                                               | Padding = 0   |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 503         |          Length = 28          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       templateId = 501        |  informationElementIndex = 0  |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |     mibSubIdentifier = 1      |        templateId = 501       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |  informationElementIndex = 1  |      mibSubIdentifier = 2     |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       templateId = 501        |  informationElementIndex = 2  |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |     mibSubIdentifier = 3      |        templateId = 501       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |  informationElementIndex = 3  |      mibSubIdentifier = 6     |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+            Figure 28: Example of ospfNbrEntry OID Data ExportAitken, et al.               Standards Track                   [Page 48]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 500         |          Length = 52          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |Semantic=0xFF  |     Template ID = 501         |        ...    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       ospfNbrIpAddr = 192.0.2.1               |        ...    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       ospfNbrAddressLessIndex = 0             |        ...    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       ospfNbrRtrId = 1.1.1.1                  |ospfNbrState=8 |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |Semantic=0xFF  |     Template ID = 501         |        ...    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       ospfNbrIpAddr = 192.0.2.2               |        ...    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       ospfNbrAddressLessIndex = 0             |        ...    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       ospfNbrRtrId = 2.2.2.2                  |ospfNbrState=8 |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |Semantic=0xFF  |     Template ID = 501         |        ...    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       ospfNbrIpAddr = 192.0.2.3               |        ...    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       ospfNbrAddressLessIndex = 0             |        ...    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       ospfNbrRtrId = 3.3.3.3                  |ospfNbrState=1 |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+            Figure 29: Example of Data Export for ospfNbrEntry6.4.  Exporting Augmented Conceptual Row: Mapping IF-MIB ID to Name   The ifTable, defined in the IF-MIB [RFC2863], is augmented by the   ifXTable (defined in the same MIB module).   The OID of the ifEntry is 1.3.6.1.2.1.2.2.1, which is encoded using   ASN.1/BER to "06082B06010201020201" at 10 octets long, while the OID   of the augmenting ifXEntry is 1.3.6.1.2.1.31.1.1.1, which is encoded   using ASN.1/BER to "060A2B060102011F01010101" at 12 octets long.   This example demonstrates how columnar objects from the base   conceptual row and the augmenting row can be exported in a single   mibObjectValueRow Information Element.Aitken, et al.               Standards Track                   [Page 49]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017   Table 6 shows the fields that will be exported.        +---------+------------------+-------+-------------------+        | ifIndex | ifType           | ifMtu | ifName            |        +---------+------------------+-------+-------------------+        | 1       | ethernetCsmacd:6 | 1500  | Ethernet 10       |        | 2       | ethernetCsmacd:6 | 1500  | Ethernet 20       |        | 3       | ethernetCsmacd:6 | 1500  | FastEthernet 30   |        +---------+------------------+-------+-------------------+                           Table 6: IF-MIB Data   The OIDs that will be used to export this table are shown in Table 7.   +---------+------------------------+--------------------------------+   | Entity  | Full OID               | Exported as                    |   +---------+------------------------+--------------------------------+   | ifEntry | 1.3.6.1.2.1.2.2.1      | OID   = 1.3.6.1.2.1.2.2.1      |   | ifIndex | 1.3.6.1.2.1.2.2.1.1    | subID = 1                      |   | ifType  | 1.3.6.1.2.1.2.2.1.3    | subID = 3                      |   | ifMtu   | 1.3.6.1.2.1.2.2.1.4    | subID = 4                      |   | ifName  | 1.3.6.1.2.1.31.1.1.1.1 | OID   = 1.3.6.1.2.1.31.1.1.1.1 |   +---------+------------------------+--------------------------------+                           Table 7: IF-MIB OIDs   Figure 30 shows the Templates exported to support the   mibObjectValueRow Information Element.  Figure 31 shows the example   OID Data for the conceptual row exported in mibObjectValueRow to   match Table 7.  Figure 32 shows the example data export as per   Table 6.Aitken, et al.               Standards Track                   [Page 50]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 2           |          Length = 12          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID = 600       |         Field Count = 1       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |0| IE = mibObjectValueRow      |         Field Length = 24     |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 3           |          Length = 26          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID = 601       |        Field Count = 4        |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |   Scope Field Count = 1       |0| IE = mibObjectValueInteger  |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 1       |0| IE = mibObjectValueInteger  |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 2       |0| IE = mibObjectValueInteger  |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 2       |0|IE =mibObjectValueOctetString|     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 65535   |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+                                     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+                                     |       Set ID = 3              |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Length = 22          |      Template ID = 602        |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Count = 3        |   Scope Field Count = 2       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |0| IE = templateId             |        Field Length = 2       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |0| IE = informationElementIndex|        Field Length = 2       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |0| IE = mibObjectIdentifier    |        Field Length = 65535   |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+Aitken, et al.               Standards Track                   [Page 51]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 3           |          Length = 22          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID = 603       |        Field Count = 3        |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |   Scope Field Count = 2       |0| IE = templateId             |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 2       |0| IE = informationElementIndex|     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 2       |0| IE = mibSubIdentifier       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 2       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+           Figure 30: Example of Augmented ifEntry Template and                           Options Template SetsAitken, et al.               Standards Track                   [Page 52]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 602         |          Length = 40          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID = 600       | informationElementIndex = 0   |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |   VLEN = 10   | mibObjectIdentifier ...                       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |              ifEntry = 1.3.6.1.2.1.2.2.1                      |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |              06082B06010201020201             |   Padding = 0 |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        templateId = 601       | informationElementIndex = 3   |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |   VLEN = 12   | mibObjectIdentifier ifName ...                |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |              ifName = 1.3.6.1.2.1.31.1.1.1.1                  |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |              060A2B060102011F01010101                         |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |               |                  Padding = 0                  |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 603         |          Length = 22          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       templateId = 601        |  informationElementIndex = 0  |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |     mibSubIdentifier = 1      |        templateId = 601       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |  informationElementIndex = 1  |      mibSubIdentifier = 3     |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       templateId = 601        |  informationElementIndex = 2  |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |     mibSubIdentifier = 4      |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+          Figure 31: Example of Augmented ifEntry OID Data ExportAitken, et al.               Standards Track                   [Page 53]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 600         |          Length = 68          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |Semantic=0xFF  |     Template ID = 601         | ifIndex = 1   |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       ifType = 6              |        ifMtu = 1500           |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |  Length = 11  |      ifName = Ethernet 10                     |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                        ...                                    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                        ...                                    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |Semantic=0xFF  |     Template ID = 601         | ifIndex = 2   |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       ifType = 6              |        ifMtu = 1500           |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |  Length = 11  |      ifName = Ethernet 20                     |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                        ...                                    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                        ...                                    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |Semantic=0xFF  |     Template ID = 601         | ifIndex = 3   |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       ifType = 6              |        ifMtu = 1500           |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |  Length = 15  |      ifName = FastEthernet 30                 |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                        ...                                    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                        ...                                    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                        ...                                    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+          Figure 32: Example of Data Export for Augmented ifEntryAitken, et al.               Standards Track                   [Page 54]

RFC 8038           Exporting MIB Variables with IPFIX           May 20176.5.  Exporting a Columnar Object: ipIfStatsInForwDatagrams   It may be that the full set of columnar objects that are supported by   a conceptual row are not required to be exported.  Rather than use   the IPFIX Structured Data [RFC6313] method, the mibIndexIndicator   method can be used to provide the relationship between fields.   This example shows the MIB objects that are part of the INDEX of the   conceptual row being exported in the correct order and then being   referred to by using mibIndexIndicator.   This example shows the export of ipIfStatsInForwDatagrams from the   IP-MIB [RFC4293].  ipIfStatsInForwDatagrams is a columnar object that   is part of the ipIfStatsTable conceptual table.  This is comprised of   ipIfStatsEntry conceptual rows.   The ipIfStatsTable conceptual table is indexed by ipIfStatsIPVersion   and ipIfStatsIfIndex.   The Options Template Record for the example Data Record contains the   following Information Elements:   1.  ipIfStatsIPVersion (1.3.6.1.2.1.4.31.3.1.1) (Scope Field)       (encoded using ASN.1/BER to "060A2B06010201041F030101" at       12 octets long)   2.  ipIfStatsIfIndex (1.3.6.1.2.1.4.31.3.1.2) (Scope Field)       (encoded using ASN.1/BER to "060A2B06010201041F030102" at       12 octets long)   3.  ipIfStatsInForwDatagrams (1.3.6.1.2.1.4.31.3.1.12) (non-Scope       Field)       (encoded using ASN.1/BER to "060A2B06010201041F03010C" at       12 octets long)   Note that ipIfStatsIfIndex has been reduced-size encoded to 2 octets   in the following example.  An exporting device with more interfaces   would use the full length.Aitken, et al.               Standards Track                   [Page 55]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017   Figure 33 shows the exported Options Template Set.      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 3           |          Length = 22          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID = 701       |        Field Count = 3        |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |     Scope Field Count = 2     |0|Scope 1=mibObjectValueInteger|     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |   Scope Field 1 Length = 1    |0|Scope 2=mibObjectValueInteger|     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |   Scope Field 1 Length = 2    |0| IE = mibObjectValueCounter  |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |           Field Length = 4    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+    Figure 33: Example of an Options Template for an Indexed MIB Object                          with Two Index Objects   Figure 34 shows the exported MIB Field Options Template used to   export the required mibObjectValue Information Element metadata.   This example of the MIB Field Options Template includes the   mibIndexIndicator to indicate that some of the other fields in the   Data Records are index objects.      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 3           |          Length = 26          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID = 702       |        Field Count = 4        |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |   Scope Field Count = 2       |0| IE = templateId             |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 2       |0| IE = informationElementIndex|     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 2       |0| IE = mibIndexIndicator      |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 1       |0| IE = mibObjectIdentifier    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 65535   |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     Figure 34: Example of a MIB Field Options Template for an Indexed                     MIB Object with Two Index ObjectsAitken, et al.               Standards Track                   [Page 56]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017   Figure 35 shows the exported MIB Field Options Data used to export   the required mibObjectValue Information Element metadata.  Note that   the first two Data Records have all their mibIndexIndicator bits set   to 0.  The third mibIndexIndicator has the value "00000011" to show   that the first two fields in the Data Record are the INDEXes for this   columnar object.      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 702         |          Length = 58          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID = 701       | informationElementIndex = 0   |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |Index 00000000 | VLEN = 12     | mibObjectIdentifier       ... |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |              "1.3.6.1.2.1.4.31.3.1.1"                     ... |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |               060A2B06010201041F030101                    ... |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                               |        templateId = 701       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     | informationElementIndex = 1   |Index 00000000 |   VLEN = 12   |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |  mibObjectIdentifier = "1.3.6.1.2.1.4.31.3.1.2"           ... |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                         060A2B06010201041F030102          ... |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                                                           ... |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        templateId = 701       | informationElementIndex = 2   |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     | Index 00000011 |  VLEN = 12   | mibObjectIdentifier      ...  |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                  "1.3.6.1.2.1.4.31.3.1.12"               ...  |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                   060A2B06010201041F03010C               ...  |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                               |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     Figure 35: Example of a MIB Field Options Data Set for an Indexed                     MIB Object with Two Index ObjectsAitken, et al.               Standards Track                   [Page 57]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017   Figure 36 shows the Data Records that export the values of the three   mibObjectValue Information Elements.      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 701         |          Length = 18          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     | ipVer = 1     |     ifIndex = 10              |  ...          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |    InForwDatagrams = 10000                    | ipVer = 2     |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |    ifIndex = 10               | InForwDatagrams = 20000       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |             ...               |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+      Figure 36: Example of a MIB Data Set for an Indexed MIB Object                          with Two Index Objects6.6.  Exporting a Columnar Object Indexed by Information Elements:      ifOutQLen   If a Packet Sampling (PSAMP) Packet Report [RFC5476] was generated on   any dropped packets on an interface, then it may be desirable to know   if the send queue on the output interface was full.  This could be   done by exporting the size of the send queue (ifOutQLen) in the same   Data Record as the PSAMP Packet Report.   The exported data looks like:   +-----------+-----------+---------+--------------+------------------+   |  SRC ADDR |  DST ADDR | PKT LEN |    OUTPUT    | OUTPUT QUEUE LEN |   |           |           |         |  INTERFACE   |   (ifOutQLen)    |   +-----------+-----------+---------+--------------+------------------+   | 192.0.2.1 | 192.0.2.3 |   150   | Eth 1/0 (15) |        45        |   | 192.0.2.4 | 192.0.2.9 |   350   | Eth 1/0 (15) |        45        |   | 192.0.2.3 | 192.0.2.9 |   650   | Eth 1/0 (15) |        23        |   | 192.0.2.4 | 192.0.2.6 |   350   | Eth 1/1 (16) |         0        |   +-----------+-----------+---------+--------------+------------------+         Table 8: Packet Report with Interface Output Queue Length                             (ifOutQLen) Data   The ifOutQLen MIB object, defined in the IF-MIB [RFC2863], provides   the length of the output packet queue.  This columnar object is part   of the ifEntry conceptual row and indexed by the interface index   (ifIndex).Aitken, et al.               Standards Track                   [Page 58]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017   This relationship between the ifOutQLen field and the index field is   exported using mibIndexIndicator in the MIB Field Options Template.   The value of "00001000" flags the index fields concisely.   The Template Record for the example Data Record contains the   following Information Elements:   1.  sourceIPv4Address   2.  destinationIPv4Address   3.  totalLengthIPv4   4.  egressInterface   5.  ifOutQLen (indexed by egressInterface)   Figure 37 shows the exported Template Set detailing the Template for   exporting a PSAMP Report with ifOutQLen.  Figures 38 and 39 show the   MIB Field Options Template and Data Record.      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 2           |          Length = 28          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID = 703       |        Field Count = 5        |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |0| IE = sourceIPv4Address      |        Field Length = 4       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |0| IE = destinationIPv4Address |        Field Length = 4       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |0| IE = totalLengthIPv4        |        Field Length = 4       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |0| IE = egressInterface        |        Field Length = 4       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |0| IE = mibObjectValueGauge    |        Field Length = 4       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     Figure 37: Example of Template for a PSAMP Report with ifOutQLen                        Indexed by egressInterfaceAitken, et al.               Standards Track                   [Page 59]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 3           |          Length = 26          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID = 704       |        Field Count = 4        |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |   Scope Field Count = 2       |0| IE = templateId             |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 2       |0| IE = informationElementIndex|     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 2       |0| IE = mibIndexIndicator      |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 1       |0| IE = mibObjectIdentifier    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 65535   |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+    Figure 38: Example of MIB Field Options Template for a PSAMP Report                 with ifOutQLen Indexed by egressInterface      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 704         |          Length = 21          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID = 703       | informationElementIndex = 4   |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |Index 00001000  | VLEN = 11    | mibObjectIdentifier    ...    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |             "1.3.6.1.2.1.2.2.1.21"                     ...    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |              06092B0601020102020115                    ...    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |               |     +-+-+-+-+-+-+-+-+      Figure 39: Example of MIB Field Options Data Record for a PSAMP             Report with ifOutQLen Indexed by egressInterface   The corresponding IPFIX Data Record is shown in Figure 40.  For the   sake of the example, the interface index of "Eth 1/0" is 15 and the   interface index of "Eth 1/1" is 16.Aitken, et al.               Standards Track                   [Page 60]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 703         |          Length = 84          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                          192.0.2.1                            |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                          192.0.2.3                            |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                             150                               |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                        15 (Eth 1/0)                           |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                              45                               |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                          192.0.2.4                            |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                          192.0.2.9                            |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                             350                               |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                        15 (Eth 1/0)                           |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                              45                               |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                          192.0.2.3                            |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                          192.0.2.9                            |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                             650                               |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                        15 (Eth 1/0)                           |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                              23                               |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                          192.0.2.4                            |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                          192.0.2.6                            |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                             350                               |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                        16 (Eth 1/1)                           |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                               0                               |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+         Figure 40: Example of PSAMP Packet Report with ifOutQLen                        Indexed by egressInterfaceAitken, et al.               Standards Track                   [Page 61]

RFC 8038           Exporting MIB Variables with IPFIX           May 20176.7.  Exporting with Multiple Contexts: The OSPF Neighbor Row Revisited   If the context used to export the MIB objects is the default one, no   extra context fields are required.  This example demonstrates how to   handle the case when the context needs to be specified.  It is based   on the previous example (Section 6.3).   The OSPF details of the conceptual row that was exported perSection 6.3 would be suitable if there were only one OSPF process   running at the Observation Point.  If multiple OSPF processes are   present, then they can be differentiated by also exporting the   mibContextEngineID and mibContextName.   The following fields will be exported:   +------------------+----------------+-------------------------+-----+   | Object           | ID             | mibObjectValue          | Len |   +------------------+----------------+-------------------------+-----+   | ospfNbrIpAddr    | ospfNbrEntry 1 | mibObjectValueIPAddress |  4  |   | ospfNbrAddress-  | ospfNbrEntry 2 | mibObjectValueInteger   |  4  |   | -LessIndex       |                |                         |     |   | ospfNbrRtrId     | ospfNbrEntry 3 | mibObjectValueIPAddress |  4  |   | ospfNbrState     | ospfNbrEntry 6 | mibObjectValueInteger   |  1  |   +------------------+----------------+-------------------------+-----+                   Table 9: OSPF Neighbor Entry Objects   The example contextEngineID matches the example from [RFC3411] for   Acme Networks: "'800002B804616263'H (enterprise 696, string "abc")".   Figure 41 shows the Templates exported to support a mibObjectValueRow   that is defined within a context.  Figure 42 shows the example OID   Data for the conceptual row exported in mibObjectValueRow.  These are   unchanged from the previous example (Section 6.3).  Figure 43 shows   the example data for two OSPF neighbors.  Although these have   identical INDEX/scope values, the context information indicates that   they come from different OSPF processes.  Note that the OID for   ospfNbrEntry has been encoded using ASN.1/BER to   "06082B060102010E0A01" at 10 octets long.Aitken, et al.               Standards Track                   [Page 62]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 2           |          Length = 20          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID = 800       |         Field Count = 3       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |0| IE = mibContextEngineID     |         Field Length = 8      |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |0| IE = mibContextName         |         Field Length = 4      |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |0| IE = mibObjectValueRow      |         Field Length = 16     |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 3           |          Length = 26          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID = 801       |        Field Count = 4        |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |   Scope Field Count = 2       |0| IE = mibObjectValueIPAddress|     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 4       |0| IE = mibObjectValueInteger  |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 4       |0| IE = mibObjectValueIPAddress|     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 4       |0| IE = mibObjectValueInteger  |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 1       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+                                     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+                                     |       Set ID = 3              |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Length = 22          |      Template ID = 802        |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Count = 3        |  Scope Field Count = 2        |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |0| IE = templateId             |        Field Length = 2       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |0| IE = informationElementIndex|        Field Length = 2       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |0| IE = mibObjectIdentifier    |        Field Length = 65535   |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+Aitken, et al.               Standards Track                   [Page 63]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 3           |          Length = 22          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID = 803       |        Field Count = 3        |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |   Scope Field Count = 2       |0| IE = templateId             |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 2       |0| IE = informationElementIndex|     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 2       |0| IE = mibSubIdentifier       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |        Field Length = 2       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+   Figure 41: Example of ospfNbrEntry Template and Options Template Sets                               with Context      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 802         |          Length = 20          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       Template ID = 800       | informationElementIndex = 2   |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |   VLEN = 10   | mibObjectIdentifier = "1.3.6.1.2.1.14.10.1"   |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                     06082B060102010E0A01                      |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |                                               | Padding = 0   |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 803         |          Length = 28          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       templateId = 801        |  informationElementIndex = 0  |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |     mibSubIdentifier = 1      |        templateId = 801       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |  informationElementIndex = 1  |      mibSubIdentifier = 2     |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       templateId = 801        |  informationElementIndex = 2  |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |     mibSubIdentifier = 3      |        templateId = 801       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |  informationElementIndex = 3  |      mibSubIdentifier = 6     |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+      Figure 42: Example of ospfNbrEntry OID Data Export with ContextAitken, et al.               Standards Track                   [Page 64]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017      0                   1                   2                   3      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |          Set ID = 800         |          Length = 60          |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |  mibContextEngineID = 800002B804616263                        |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |  ... mibContextEngineID                                       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |  mibContextName = con1                                        |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |Semantic=0xFF  |     Template ID = 801         |        ...    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       ospfNbrIpAddr = 192.0.2.1               |        ...    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       ospfNbrAddressLessIndex = 0             |        ...    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       ospfNbrRtrId = 1.1.1.1                  |ospfNbrState=8 |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |  mibContextEngineID = 800002B804616263                        |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |  ... mibContextEngineID                                       |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |  mibContextName = con2                                        |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |Semantic=0xFF  |     Template ID = 801         |        ...    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       ospfNbrIpAddr = 192.0.2.2               |        ...    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       ospfNbrAddressLessIndex = 0             |        ...    |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+     |       ospfNbrRtrId = 2.2.2.2                  |ospfNbrState=8 |     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+      Figure 43: Example of Data Export for ospfNbrEntry with Context7.  Configuration Considerations   When configuring a MIB OID for export, consideration should be given   to whether the SNMP context should also be configurable.  If a   non-default context is used, then it should be associated with the   fields as perSection 5.6.Aitken, et al.               Standards Track                   [Page 65]

RFC 8038           Exporting MIB Variables with IPFIX           May 20178.  The Collecting Process's Side   The specifications inSection 9 of [RFC7011] also apply to Collectors   that implement this specification.  In addition, the following   specifications should be noted:   o  A Collecting Process that implements this specification MUST store      the Data Records containing the OID object type definitions with      the same retention policy as Templates.   o  A Collecting Process that implements this specification SHOULD      have access to MIB modules in order to look up the received MIB      Object Identifiers and find the full type definition and name of      MIB OID fields used in received Templates.   o  It should be noted that, because reduced-size encoding MAY be used      by the Exporting Process, the Collecting Process cannot assume      that a received size for a field is the maximum size it should      expect for that field.   o  If a Collecting Process receives a MIB Object Identifier that it      cannot decode, it MAY log a warning.   o  A Collecting Process MUST support the three options for handling      columnar objects detailed inSection 5.8.9.  Applicability   Making available the many and varied items from MIB modules opens up   a wide range of possible applications for the IPFIX protocol, some   quite different from the usual Flow information.   Some monitoring applications periodically export a mapping of   interface ID to interface name using IPFIX Options Templates.  This   could be expanded to include the ifInUcastPkts MIB object as defined   in the IF-MIB [RFC2863], indexed using the ingressInterface   Information Element.  This would provide the input statistics for   each interface; these statistics can be compared to the Flow   information to ensure that the sampling rate is as expected, or, in   the absence of sampling, to ensure that all expected packets are   being monitored.Aitken, et al.               Standards Track                   [Page 66]

RFC 8038           Exporting MIB Variables with IPFIX           May 201710.  Security Considerations   For this extension to the IPFIX protocol, the same security   considerations as those for the IPFIX protocol apply [RFC7011].   If the Exporter is generating or capturing the field values itself,   e.g., using the MIB objects only as an encoding or type mechanism,   there are no extra security considerations beyond standard IPFIX.   However, if the Exporter is implemented as an SNMP manager accessing   an SNMP agent, it MUST authenticate itself to the SNMP agent   [RFC3414] [RFC5591] [RFC5592] [RFC6353], and the SNMP agent MUST   enforce SNMP access control rules [RFC3415] as required by the SNMP   architecture [RFC3411].   Access to particular MIB objects is controlled by the configuration   of the IPFIX Exporter.  This is consistent with the way IPFIX   controls access to other Information Elements in general.   The configuration of an IPFIX Exporter determines which MIB objects   are included in IPFIX Data Records sent to certain Collectors.   Network operators should take care that the only MIB objects that are   included in IPFIX Data Records are objects that the receiving   Collector is allowed to receive.  Note that multiple users may have   access to the data from the Collector.   When exporting MIB objects that may be considered sensitive or   vulnerable in some network environments (as mentioned in the Security   Considerations section of the RFC containing the MIB module), the   Exporter should consider using anonymization techniques per [RFC6235]   if the information is anonymizable.  Consumers of exported data   should therefore be able to handle the kinds of data modifications   that are described in [RFC6235].Aitken, et al.               Standards Track                   [Page 67]

RFC 8038           Exporting MIB Variables with IPFIX           May 201711.  IANA Considerations11.1.  New IPFIX Semantics   New IPFIX semantics have been allocated in IANA's IPFIX registry   [IANA-IPFIX] perSection 6 of [RFC7012], as defined in the   subsections below.11.1.1.  snmpCounter   An integral value reporting the value of a counter, identical to the   Counter32 and Counter64 semantics in [RFC2578], as determined by the   Field Length.   This is similar to IPFIX's totalCounter semantic, except that total   counters have an initial value of 0 but SNMP counters do not.   IANA has assigned value 7 to snmpCounter.11.1.2.  snmpGauge   An integral value identical to the Gauge32 semantic in [RFC2578] and   the Gauge64 semantic in [RFC2856], as determined by the Field Length.   IANA has assigned value 8 to snmpGauge.Aitken, et al.               Standards Track                   [Page 68]

RFC 8038           Exporting MIB Variables with IPFIX           May 201711.2.  New IPFIX Information Elements   The new Information Elements in Table 10 have been allocated in   IANA's IPFIX registry [IANA-IPFIX], as defined in the subsections   below.   In each case, the "Units" and "Range" have been left blank, since   these are not applicable.                 +-----------+---------------------------+                 | ElementId | Name                      |                 +-----------+---------------------------+                 | 434       | mibObjectValueInteger     |                 | 435       | mibObjectValueOctetString |                 | 436       | mibObjectValueOID         |                 | 437       | mibObjectValueBits        |                 | 438       | mibObjectValueIPAddress   |                 | 439       | mibObjectValueCounter     |                 | 440       | mibObjectValueGauge       |                 | 441       | mibObjectValueTimeTicks   |                 | 442       | mibObjectValueUnsigned    |                 | 443       | mibObjectValueTable       |                 | 444       | mibObjectValueRow         |                 | 445       | mibObjectIdentifier       |                 | 446       | mibSubIdentifier          |                 | 447       | mibIndexIndicator         |                 | 448       | mibCaptureTimeSemantics   |                 | 449       | mibContextEngineID        |                 | 450       | mibContextName            |                 | 451       | mibObjectName             |                 | 452       | mibObjectDescription      |                 | 453       | mibObjectSyntax           |                 | 454       | mibModuleName             |                 +-----------+---------------------------+                    Table 10: New Information Elements11.2.1.  New MIB Object Value Information Elements11.2.1.1.  mibObjectValueInteger   A new Information Element "mibObjectValueInteger" has been allocated   in IANA's IPFIX registry [IANA-IPFIX], with the following definition:      Description: An IPFIX Information Element that denotes that the      integer value of a MIB object will be exported.  The MIB Object      Identifier ("mibObjectIdentifier") for this field MUST be exported      in a MIB Field Option or via another means.  This InformationAitken, et al.               Standards Track                   [Page 69]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017      Element is used for MIB objects with the Base syntax of Integer32      and INTEGER with IPFIX reduced-size encoding used as required.      The value is encoded as per the standard IPFIX Abstract Data Type      of signed32.      Abstract Data Type: signed32      Data Type Semantics: quantity      ElementId: 434      Status: current      Reference:RFC 803811.2.1.2.  mibObjectValueOctetString   A new Information Element "mibObjectValueOctetString" has been   allocated in IANA's IPFIX registry [IANA-IPFIX], with the following   definition:      Description: An IPFIX Information Element that denotes that an      Octet String or Opaque value of a MIB object will be exported.      The MIB Object Identifier ("mibObjectIdentifier") for this field      MUST be exported in a MIB Field Option or via another means.  This      Information Element is used for MIB objects with the Base syntax      of OCTET STRING and Opaque.  The value is encoded as per the      standard IPFIX Abstract Data Type of octetArray.      Abstract Data Type: octetArray      Data Type Semantics: default      ElementId: 435      Status: current      Reference:RFC 803811.2.1.3.  mibObjectValueOID   A new Information Element "mibObjectValueOID" has been allocated in   IANA's IPFIX registry [IANA-IPFIX], with the following definition:      Description: An IPFIX Information Element that denotes that an      Object Identifier or OID value of a MIB object will be exported.      The MIB Object Identifier ("mibObjectIdentifier") for this field      MUST be exported in a MIB Field Option or via another means.  ThisAitken, et al.               Standards Track                   [Page 70]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017      Information Element is used for MIB objects with the Base syntax      of OBJECT IDENTIFIER.  Note: In this case, the      "mibObjectIdentifier" defines which MIB object is being exported,      and the "mibObjectValueOID" field will contain the OID value of      that MIB object.  The mibObjectValueOID Information Element is      encoded as ASN.1/BER [X.690] in an octetArray.      Abstract Data Type: octetArray      Data Type Semantics: default      ElementId: 436      Status: current      Reference:RFC 803811.2.1.4.  mibObjectValueBits   A new Information Element "mibObjectValueBits" has been allocated in   IANA's IPFIX registry [IANA-IPFIX], with the following definition:      Description: An IPFIX Information Element that denotes that a set      of Enumerated flags or bits from a MIB object will be exported.      The MIB Object Identifier ("mibObjectIdentifier") for this field      MUST be exported in a MIB Field Option or via another means.  This      Information Element is used for MIB objects with the Base syntax      of BITS.  The flags or bits are encoded as per the standard IPFIX      Abstract Data Type of octetArray, with sufficient length to      accommodate the required number of bits.  If the number of bits is      not an integer multiple of octets, then the most significant bits      at the end of the octetArray MUST be set to 0.      Abstract Data Type: octetArray      Data Type Semantics: flags      ElementId: 437      Status: current      Reference:RFC 8038Aitken, et al.               Standards Track                   [Page 71]

RFC 8038           Exporting MIB Variables with IPFIX           May 201711.2.1.5.  mibObjectValueIPAddress   A new Information Element "mibObjectValueIPAddress" has been   allocated in IANA's IPFIX registry [IANA-IPFIX], with the following   definition:      Description: An IPFIX Information Element that denotes that the      IPv4 address value of a MIB object will be exported.  The MIB      Object Identifier ("mibObjectIdentifier") for this field MUST be      exported in a MIB Field Option or via another means.  This      Information Element is used for MIB objects with the Base syntax      of IpAddress.  The value is encoded as per the standard IPFIX      Abstract Data Type of ipv4Address.      Abstract Data Type: ipv4Address      Data Type Semantics: default      ElementId: 438      Status: current      Reference:RFC 803811.2.1.6.  mibObjectValueCounter   A new Information Element "mibObjectValueCounter" has been allocated   in IANA's IPFIX registry [IANA-IPFIX], with the following definition:      Description: An IPFIX Information Element that denotes that the      counter value of a MIB object will be exported.  The MIB Object      Identifier ("mibObjectIdentifier") for this field MUST be exported      in a MIB Field Option or via another means.  This Information      Element is used for MIB objects with the Base syntax of Counter32      or Counter64 with IPFIX reduced-size encoding used as required.      The value is encoded as per the standard IPFIX Abstract Data Type      of unsigned64.      Abstract Data Type: unsigned64      Data Type Semantics: snmpCounter      ElementId: 439      Status: current      Reference:RFC 8038Aitken, et al.               Standards Track                   [Page 72]

RFC 8038           Exporting MIB Variables with IPFIX           May 201711.2.1.7.  mibObjectValueGauge   A new Information Element "mibObjectValueGauge" has been allocated in   IANA's IPFIX registry [IANA-IPFIX], with the following definition:      Description: An IPFIX Information Element that denotes that the      Gauge value of a MIB object will be exported.  The MIB Object      Identifier ("mibObjectIdentifier") for this field MUST be exported      in a MIB Field Option or via another means.  This Information      Element is used for MIB objects with the Base syntax of Gauge32.      The value is encoded as per the standard IPFIX Abstract Data Type      of unsigned32.  This value represents a non-negative integer that      may increase or decrease but that shall never exceed a maximum      value or fall below a minimum value.      Abstract Data Type: unsigned32      Data Type Semantics: snmpGauge      ElementId: 440      Status: current      Reference:RFC 803811.2.1.8.  mibObjectValueTimeTicks   A new Information Element "mibObjectValueTimeTicks" has been   allocated in IANA's IPFIX registry [IANA-IPFIX], with the following   definition:      Description: An IPFIX Information Element that denotes that the      TimeTicks value of a MIB object will be exported.  The MIB Object      Identifier ("mibObjectIdentifier") for this field MUST be exported      in a MIB Field Option or via another means.  This Information      Element is used for MIB objects with the Base syntax of TimeTicks.      The value is encoded as per the standard IPFIX Abstract Data Type      of unsigned32.      Abstract Data Type: unsigned32      Data Type Semantics: quantity      ElementId: 441      Status: current      Reference:RFC 8038Aitken, et al.               Standards Track                   [Page 73]

RFC 8038           Exporting MIB Variables with IPFIX           May 201711.2.1.9.  mibObjectValueUnsigned   A new Information Element "mibObjectValueUnsigned" has been allocated   in IANA's IPFIX registry [IANA-IPFIX], with the following definition:      Description: An IPFIX Information Element that denotes that an      unsigned integer value of a MIB object will be exported.  The MIB      Object Identifier ("mibObjectIdentifier") for this field MUST be      exported in a MIB Field Option or via another means.  This      Information Element is used for MIB objects with the Base syntax      of unsigned32 with IPFIX reduced-size encoding used as required.      The value is encoded as per the standard IPFIX Abstract Data Type      of unsigned32.      Abstract Data Type: unsigned32      Data Type Semantics: quantity      ElementId: 442      Status: current      Reference:RFC 803811.2.1.10.  mibObjectValueTable   A new Information Element "mibObjectValueTable" has been allocated in   IANA's IPFIX registry [IANA-IPFIX], with the following definition:      Description: An IPFIX Information Element that denotes that a      complete or partial conceptual table will be exported.  The MIB      Object Identifier ("mibObjectIdentifier") for this field MUST be      exported in a MIB Field Option or via another means.  This      Information Element is used for MIB objects with a syntax of      SEQUENCE OF.  This is encoded as a subTemplateList of      mibObjectValue Information Elements.  The Template specified in      the subTemplateList MUST be an Options Template and MUST include      all the objects listed in the INDEX clause as Scope Fields.      Abstract Data Type: subTemplateList      Data Type Semantics: list      ElementId: 443      Status: current      Reference:RFC 8038Aitken, et al.               Standards Track                   [Page 74]

RFC 8038           Exporting MIB Variables with IPFIX           May 201711.2.1.11.  mibObjectValueRow   A new Information Element "mibObjectValueRow" has been allocated in   IANA's IPFIX registry [IANA-IPFIX], with the following definition:      Description: An IPFIX Information Element that denotes that a      single row of a conceptual table will be exported.  The MIB Object      Identifier ("mibObjectIdentifier") for this field MUST be exported      in a MIB Field Option or via another means.  This Information      Element is used for MIB objects with a syntax of SEQUENCE.  This      is encoded as a subTemplateList of mibObjectValue Information      Elements.  The subTemplateList exported MUST contain exactly one      row (i.e., one instance of the subTemplate).  The Template      specified in the subTemplateList MUST be an Options Template and      MUST include all the objects listed in the INDEX clause as Scope      Fields.      Abstract Data Type: subTemplateList      Data Type Semantics: list      ElementId: 444      Status: current      Reference:RFC 803811.2.2.  New MIB Field Options Information Elements11.2.2.1.  mibObjectIdentifier   A new Information Element "mibObjectIdentifier" has been allocated in   IANA's IPFIX registry [IANA-IPFIX], with the following definition:      Description: An IPFIX Information Element that denotes that a MIB      Object Identifier (MIB OID) is exported in the (Options)      Template Record.  The mibObjectIdentifier Information Element      contains the OID assigned to the MIB object type definition      encoded as ASN.1/BER [X.690].      Abstract Data Type: octetArray      Data Type Semantics: default      ElementId: 445Aitken, et al.               Standards Track                   [Page 75]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017      Status: current      Reference:RFC 803811.2.2.2.  mibSubIdentifier   A new Information Element "mibSubIdentifier" has been allocated in   IANA's IPFIX registry [IANA-IPFIX], with the following definition:      Description: A non-negative sub-identifier of an Object Identifier      (OID).      Abstract Data Type: unsigned32      Data Type Semantics: identifier      ElementId: 446      Status: current      Reference:RFC 803811.2.2.3.  mibIndexIndicator   A new Information Element "mibIndexIndicator" has been allocated in   IANA's IPFIX registry [IANA-IPFIX], with the following definition:      Description: A set of bit fields that is used for marking the      Information Elements of a Data Record that serve as INDEX MIB      objects for an indexed columnar MIB object.  Each bit represents      an Information Element in the Data Record, with the n-th least      significant bit representing the n-th Information Element.  A bit      set to 1 indicates that the corresponding Information Element is      an index of the columnar object represented by the mibObjectValue.      A bit set to 0 indicates that this is not the case.      If the Data Record contains more than 64 Information Elements, the      corresponding Template SHOULD be designed such that all index      fields are among the first 64 Information Elements, because the      mibIndexIndicator only contains 64 bits.  If the Data Record      contains less than 64 Information Elements, then the extra bits in      the mibIndexIndicator for which no corresponding Information      Element exists MUST have the value 0 and must be disregarded by      the Collector.  This Information Element may be exported with      IPFIX reduced-size encoding.Aitken, et al.               Standards Track                   [Page 76]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017      Abstract Data Type: unsigned64      Data Type Semantics: flags      ElementId: 447      Status: current      Reference:RFC 803811.2.2.4.  mibCaptureTimeSemantics   A new Information Element "mibCaptureTimeSemantics" has been   allocated in IANA's IPFIX registry [IANA-IPFIX], with the following   definition:      Description: Indicates when in the lifetime of the Flow the MIB      value was retrieved from the MIB for a mibObjectIdentifier.  This      is used to indicate if the value exported was collected from the      MIB closer to Flow creation or Flow export time and refers to the      Timestamp fields included in the same Data Record.  This field      SHOULD be used when exporting a mibObjectValue that specifies      counters or statistics.      If the MIB value was sampled by SNMP prior to the IPFIX Metering      Process or Exporting Process retrieving the value (i.e., the data      is already stale) and it is important to know the exact sampling      time, then an additional observationTime* element should be paired      with the OID using IPFIX Structured Data [RFC6313].  Similarly, if      different MIB capture times apply to different mibObjectValue      elements within the Data Record, then individual      mibCaptureTimeSemantics Information Elements should be paired with      each OID using IPFIX Structured Data.Aitken, et al.               Standards Track                   [Page 77]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017      Values:         0  undefined         1  begin - The value for the MIB object is captured from the            MIB when the Flow is first observed         2  end - The value for the MIB object is captured from the MIB            when the Flow ends         3  export - The value for the MIB object is captured from the            MIB at export time         4  average - The value for the MIB object is an average of            multiple captures from the MIB over the observed life of            the Flow      Abstract Data Type: unsigned8      Data Type Semantics: identifier      ElementId: 448      Status: current      Reference:RFC 803811.2.2.5.  mibContextEngineID   A new Information Element "mibContextEngineID" has been allocated in   IANA's IPFIX registry [IANA-IPFIX], with the following definition:      Description: A mibContextEngineID that specifies the SNMP      engine ID for a MIB field being exported over IPFIX.  Definition      as per[RFC3411], Section 3.3.      Abstract Data Type: octetArray      Data Type Semantics: default      ElementId: 449      Status: current      Reference:RFC 8038Aitken, et al.               Standards Track                   [Page 78]

RFC 8038           Exporting MIB Variables with IPFIX           May 201711.2.2.6.  mibContextName   A new Information Element "mibContextName" has been allocated in   IANA's IPFIX registry [IANA-IPFIX], with the following definition:      Description: An Information Element that denotes that a MIB      context name is specified for a MIB field being exported over      IPFIX.  Reference[RFC3411], Section 3.3.      Abstract Data Type: string      Data Type Semantics: default      ElementId: 450      Status: current      Reference:RFC 803811.2.3.  New MIB Type Information Elements11.2.3.1.  mibObjectName   A new Information Element "mibObjectName" has been allocated in   IANA's IPFIX registry [IANA-IPFIX], with the following definition:      Description: The name (called a descriptor in [RFC2578]) of an      object type definition.      Abstract Data Type: string      Data Type Semantics: default      ElementId: 451      Status: current      Reference:RFC 8038Aitken, et al.               Standards Track                   [Page 79]

RFC 8038           Exporting MIB Variables with IPFIX           May 201711.2.3.2.  mibObjectDescription   A new Information Element "mibObjectDescription" has been allocated   in IANA's IPFIX registry [IANA-IPFIX], with the following definition:      Description: The value of the DESCRIPTION clause of a MIB object      type definition.      Abstract Data Type: string      Data Type Semantics: default      ElementId: 452      Status: current      Reference:RFC 803811.2.3.3.  mibObjectSyntax   A new Information Element "mibObjectSyntax" has been allocated in   IANA's IPFIX registry [IANA-IPFIX], with the following definition:      Description: The value of the SYNTAX clause of a MIB object type      definition, which may include a textual convention or sub-typing.      See [RFC2578].      Abstract Data Type: string      Data Type Semantics: default      ElementId: 453      Status: current      Reference:RFC 8038Aitken, et al.               Standards Track                   [Page 80]

RFC 8038           Exporting MIB Variables with IPFIX           May 201711.2.3.4.  mibModuleName   A new Information Element "mibModuleName" has been allocated in   IANA's IPFIX registry [IANA-IPFIX], with the following definition:      Description: The textual name of the MIB module that defines a MIB      object.      Abstract Data Type: string      Data Type Semantics: default      ElementId: 454      Status: current      Reference:RFC 803812.  References12.1.  Normative References   [IANA-IPFIX]              IANA, "IP Flow Information Export (IPFIX) Entities",              <http://www.iana.org/assignments/ipfix/>.   [RFC2119]  Bradner, S., "Key words for use in RFCs to Indicate              Requirement Levels",BCP 14,RFC 2119,              DOI 10.17487/RFC2119, March 1997,              <http://www.rfc-editor.org/info/rfc2119>.   [RFC2578]  McCloghrie, K., Ed., Perkins, D., Ed., and J.              Schoenwaelder, Ed., "Structure of Management Information              Version 2 (SMIv2)", STD 58,RFC 2578,              DOI 10.17487/RFC2578, April 1999,              <http://www.rfc-editor.org/info/rfc2578>.   [RFC2856]  Bierman, A., McCloghrie, K., and R. Presuhn, "Textual              Conventions for Additional High Capacity Data Types",RFC 2856, DOI 10.17487/RFC2856, June 2000,              <http://www.rfc-editor.org/info/rfc2856>.   [RFC3411]  Harrington, D., Presuhn, R., and B. Wijnen, "An              Architecture for Describing Simple Network Management              Protocol (SNMP) Management Frameworks", STD 62,RFC 3411,              DOI 10.17487/RFC3411, December 2002,              <http://www.rfc-editor.org/info/rfc3411>.Aitken, et al.               Standards Track                   [Page 81]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017   [RFC6526]  Claise, B., Aitken, P., Johnson, A., and G. Muenz,              "IP Flow Information Export (IPFIX) Per Stream Control              Transmission Protocol (SCTP) Stream",RFC 6526,              DOI 10.17487/RFC6526, March 2012,              <http://www.rfc-editor.org/info/rfc6526>.   [RFC7011]  Claise, B., Ed., Trammell, B., Ed., and P. Aitken,              "Specification of the IP Flow Information Export (IPFIX)              Protocol for the Exchange of Flow Information", STD 77,RFC 7011, DOI 10.17487/RFC7011, September 2013,              <http://www.rfc-editor.org/info/rfc7011>.   [RFC7012]  Claise, B., Ed., and B. Trammell, Ed., "Information Model              for IP Flow Information Export (IPFIX)",RFC 7012,              DOI 10.17487/RFC7012, September 2013,              <http://www.rfc-editor.org/info/rfc7012>.   [X.690]    International Telecommunication Union, "Information              Technology - ASN.1 encoding rules: Specification of Basic              Encoding Rules (BER), Canonical Encoding Rules (CER) and              Distinguished Encoding Rules (DER)", ITU-T Recommendation              X.690, ISO/IEC 8825-1, August 2015,              <https://www.itu.int/rec/T-REC-X.690>.12.2.  Informative References   [CISCO-PROCESS-MIB]              Cisco Systems Inc., "CISCO-PROCESS-MIB.my: MIB for CPU and              process statistics", <ftp://ftp.cisco.com/pub/mibs/v2/CISCO-PROCESS-MIB.my>.   [RFC2863]  McCloghrie, K. and F. Kastenholz, "The Interfaces Group              MIB",RFC 2863, DOI 10.17487/RFC2863, June 2000,              <http://www.rfc-editor.org/info/rfc2863>.   [RFC2982]  Kavasseri, R., Ed., "Distributed Management Expression              MIB",RFC 2982, DOI 10.17487/RFC2982, October 2000,              <http://www.rfc-editor.org/info/rfc2982>.   [RFC3414]  Blumenthal, U. and B. Wijnen, "User-based Security Model              (USM) for version 3 of the Simple Network Management              Protocol (SNMPv3)", STD 62,RFC 3414,              DOI 10.17487/RFC3414, December 2002,              <http://www.rfc-editor.org/info/rfc3414>.Aitken, et al.               Standards Track                   [Page 82]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017   [RFC3415]  Wijnen, B., Presuhn, R., and K. McCloghrie, "View-based              Access Control Model (VACM) for the Simple Network              Management Protocol (SNMP)", STD 62,RFC 3415,              DOI 10.17487/RFC3415, December 2002,              <http://www.rfc-editor.org/info/rfc3415>.   [RFC3444]  Pras, A. and J. Schoenwaelder, "On the Difference between              Information Models and Data Models",RFC 3444,              DOI 10.17487/RFC3444, January 2003,              <http://www.rfc-editor.org/info/rfc3444>.   [RFC4022]  Raghunarayan, R., Ed., "Management Information Base for              the Transmission Control Protocol (TCP)",RFC 4022,              DOI 10.17487/RFC4022, March 2005,              <http://www.rfc-editor.org/info/rfc4022>.   [RFC4293]  Routhier, S., Ed., "Management Information Base for the              Internet Protocol (IP)",RFC 4293, DOI 10.17487/RFC4293,              April 2006, <http://www.rfc-editor.org/info/rfc4293>.   [RFC4750]  Joyal, D., Ed., Galecki, P., Ed., Giacalone, S., Ed.,              Coltun, R., and F. Baker, "OSPF Version 2 Management              Information Base",RFC 4750, DOI 10.17487/RFC4750,              December 2006, <http://www.rfc-editor.org/info/rfc4750>.   [RFC4960]  Stewart, R., Ed., "Stream Control Transmission Protocol",RFC 4960, DOI 10.17487/RFC4960, September 2007,              <http://www.rfc-editor.org/info/rfc4960>.   [RFC5102]  Quittek, J., Bryant, S., Claise, B., Aitken, P., and J.              Meyer, "Information Model for IP Flow Information Export",RFC 5102, DOI 10.17487/RFC5102, January 2008,              <http://www.rfc-editor.org/info/rfc5102>.   [RFC5476]  Claise, B., Ed., Johnson, A., and J. Quittek, "Packet              Sampling (PSAMP) Protocol Specifications",RFC 5476,              DOI 10.17487/RFC5476, March 2009,              <http://www.rfc-editor.org/info/rfc5476>.   [RFC5591]  Harrington, D. and W. Hardaker, "Transport Security Model              for the Simple Network Management Protocol (SNMP)",              STD 78,RFC 5591, DOI 10.17487/RFC5591, June 2009,              <http://www.rfc-editor.org/info/rfc5591>.   [RFC5592]  Harrington, D., Salowey, J., and W. Hardaker, "Secure              Shell Transport Model for the Simple Network Management              Protocol (SNMP)",RFC 5592, DOI 10.17487/RFC5592,              June 2009, <http://www.rfc-editor.org/info/rfc5592>.Aitken, et al.               Standards Track                   [Page 83]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017   [RFC6235]  Boschi, E. and B. Trammell, "IP Flow Anonymization              Support",RFC 6235, DOI 10.17487/RFC6235, May 2011,              <http://www.rfc-editor.org/info/rfc6235>.   [RFC6313]  Claise, B., Dhandapani, G., Aitken, P., and S. Yates,              "Export of Structured Data in IP Flow Information Export              (IPFIX)",RFC 6313, DOI 10.17487/RFC6313, July 2011,              <http://www.rfc-editor.org/info/rfc6313>.   [RFC6353]  Hardaker, W., "Transport Layer Security (TLS) Transport              Model for the Simple Network Management Protocol (SNMP)",              STD 78,RFC 6353, DOI 10.17487/RFC6353, July 2011,              <http://www.rfc-editor.org/info/rfc6353>.Acknowledgments   The authors would like to thank Andrew Johnson for his collaboration   on the first draft version of this document, and to thank Andrew   Feren and Brian Trammell for their detailed reviews.   Juergen Schoenwaelder was partly funded by Flamingo, a Network of   Excellence project (ICT-318488) supported by the European Commission   under its Seventh Framework Programme.Authors' Addresses   Paul Aitken (editor)   Brocade Communications Systems, Inc.   19a Canning Street, Level 3   Edinburgh, Scotland  EH3 8EG   United Kingdom   Phone: +44 203 005 0731   Email: paitken@brocade.com   Benoit Claise   Cisco Systems, Inc.   De Kleetlaan 6a b1   Diegem  1813   Belgium   Phone: +32 2 704 5622   Email: bclaise@cisco.comAitken, et al.               Standards Track                   [Page 84]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017   Srikar B S   Mojo Networks, Inc.   S. No. 7, Pinnac House II   Kothrud, Pune  411038   India   Phone: +91 94 4847 6672   Email: srikarbs@gmail.com   Colin McDowall   Brocade Communications Systems, Inc.   19a Canning Street, Level 3   Edinburgh, Scotland  EH3 8EG   United Kingdom   Phone: +44 203 005 0687   Email: cmcdowal@brocade.com   Juergen Schoenwaelder   Jacobs University Bremen   Campus Ring 1   Bremen  28725   Germany   Phone: +49 421 200 3587   Email: j.schoenwaelder@jacobs-university.deAitken, et al.               Standards Track                   [Page 85]

[8]ページ先頭