Internet Engineering Task Force (IETF)                         A. BrandtRequest for Comments: 5826                                      J. BuronCategory: Informational                              Sigma Designs, Inc.ISSN: 2070-1721                                                 G. Porcu                                                          Telecom Italia                                                              April 2010Home Automation Routing Requirements in Low-Power and Lossy NetworksAbstract   This document presents requirements specific to home control and   automation applications for Routing Over Low power and Lossy (ROLL)   networks.  In the near future, many homes will contain high numbers   of wireless devices for a wide set of purposes.  Examples include   actuators (relay, light dimmer, heating valve), sensors (wall switch,   water leak, blood pressure), and advanced controllers (radio-   frequency-based AV remote control, central server for light and heat   control).  Because such devices only cover a limited radio range,   routing is often required.  The aim of this document is to specify   the routing requirements for networks comprising such constrained   devices in a home-control and automation environment.Status of This Memo   This document is not an Internet Standards Track specification; it is   published for informational purposes.   This document is a product of the Internet Engineering Task Force   (IETF).  It represents the consensus of the IETF community.  It has   received public review and has been approved for publication by the   Internet Engineering Steering Group (IESG).  Not all documents   approved by the IESG are a candidate for any level of Internet   Standard; seeSection 2 of RFC 5741.   Information about the current status of this document, any errata,   and how to provide feedback on it may be obtained athttp://www.rfc-editor.org/info/rfc5286.Brandt, et al.                Informational                     [Page 1]

RFC 5826      Home Automation Routing Requirements in LLNs    April 2010Copyright Notice   Copyright (c) 2010 IETF Trust and the persons identified as the   document authors.  All rights reserved.   This document is subject toBCP 78 and the IETF Trust's Legal   Provisions Relating to IETF Documents   (http://trustee.ietf.org/license-info) in effect on the date of   publication of this document.  Please review these documents   carefully, as they describe your rights and restrictions with respect   to this document.  Code Components extracted from this document must   include Simplified BSD License text as described in Section 4.e of   the Trust Legal Provisions and are provided without warranty as   described in the Simplified BSD License.   This document may contain material from IETF Documents or IETF   Contributions published or made publicly available before November   10, 2008.  The person(s) controlling the copyright in some of this   material may not have granted the IETF Trust the right to allow   modifications of such material outside the IETF Standards Process.   Without obtaining an adequate license from the person(s) controlling   the copyright in such materials, this document may not be modified   outside the IETF Standards Process, and derivative works of it may   not be created outside the IETF Standards Process, except to format   it for publication as an RFC or to translate it into languages other   than English.Brandt, et al.                Informational                     [Page 2]

RFC 5826      Home Automation Routing Requirements in LLNs    April 2010Table of Contents1. Introduction ....................................................31.1. Terminology ................................................41.2. Requirements Language ......................................62. Home Automation Applications ....................................62.1. Lighting Application in Action .............................62.2. Energy Conservation and Optimizing Energy Consumption ......62.3. Moving a Remote Control Around .............................72.4. Adding a New Module to the System ..........................72.5. Controlling Battery-Operated Window Shades .................82.6. Remote Video Surveillance ..................................82.7. Healthcare .................................................92.7.1. At-Home Health Reporting ...........................102.7.2. At-Home Health Monitoring ..........................102.8. Alarm Systems .............................................103. Unique Routing Requirements of Home Automation Applications ....113.1. Constraint-Based Routing ..................................123.2. Support of Mobility .......................................123.3. Scalability ...............................................133.4. Convergence Time ..........................................133.5. Manageability .............................................143.6. Stability .................................................144. Traffic Pattern ................................................145. Security Considerations ........................................156. Acknowledgments ................................................167. References .....................................................167.1. Normative References ......................................167.2. Informative References ....................................171.  Introduction   This document presents requirements specific to home control and   automation applications for Routing Over Low power and Lossy (ROLL)   networks.  In the near future, many homes will contain high numbers   of wireless devices for a wide set of purposes.  Examples include   actuators (relay, light dimmer, heating valve), sensors (wall switch,   water leak, blood pressure), and advanced controllers.  Basic home-   control modules such as wall switches and plug-in modules may be   turned into an advanced home automation solution via the use of an   IP-enabled application responding to events generated by wall   switches, motion sensors, light sensors, rain sensors, and so on.   Network nodes may be sensors and actuators at the same time.  An   example is a wall switch for replacement in existing homes.  The push   buttons may generate events for a controller node or for activating   other actuator nodes.  At the same time, a built-in relay may act as   actuator for a controller or other remote sensors.Brandt, et al.                Informational                     [Page 3]

RFC 5826      Home Automation Routing Requirements in LLNs    April 2010   Because ROLL nodes only cover a limited radio range, routing is often   required.  These devices are usually highly constrained in terms of   resources such as battery and memory and operate in unstable   environments.  Persons moving around in a house, opening or closing a   door, or starting a microwave oven affect the reception of weak radio   signals.  Reflection and absorption may cause a reliable radio link   to turn unreliable for a period of time and then become reusable   again, thus the term "lossy".  All traffic in a ROLL network is   carried as IPv6 packets.   The connected home area is very much consumer oriented.  The   implication on network nodes is that devices are very cost sensitive,   which leads to resource-constrained environments having slow CPUs and   small memory footprints.  At the same time, nodes have to be   physically small, which puts a limit to the physical size of the   battery, and thus, the battery capacity.  As a result, it is common   for battery-operated, sensor-style nodes to shut down radio and CPU   resources for most of the time.  The radio tends to use the same   power for listening as for transmitting.   Although this document focuses its text on radio-based wireless   networks, home-automation networks may also operate using a variety   of links, such as IEEE 802.15.4, Bluetooth, Low-Power WiFi, wired or   other low-power PLC (Power-Line Communication) links.  Many such low-   power link technologies share similar characteristics with low-power   wireless and this document should be regarded as applying equally to   all such links.Section 2 describes a few typical use cases for home automation   applications.Section 3 discusses the routing requirements for   networks comprising such constrained devices in a home network   environment.  These requirements may be overlapping requirements   derived from other application-specific routing requirements   presented in [BUILDING-REQS], [RFC5673], and [RFC5548].   A full list of requirements documents may be found inSection 7.1.1.  Terminology   ROLL:          Routing Over Low-power and Lossy networks.  A ROLL                  node may be classified as a sensor, actuator, or                  controller.   Actuator:      Network node that performs some physical action.                  Dimmers and relays are examples of actuators.  If                  sufficiently powered, actuator nodes may participate                  in routing network messages.Brandt, et al.                Informational                     [Page 4]

RFC 5826      Home Automation Routing Requirements in LLNs    April 2010   Border router: Infrastructure device that connects a ROLL network to                  the Internet or some backbone network.   Channel:       Radio frequency band used to carry network packets.   Controller:    Network node that controls actuators.  Control                  decisions may be based on sensor readings, sensor                  events, scheduled actions, or incoming commands from                  the Internet or other backbone networks.  If                  sufficiently powered, controller nodes may participate                  in routing network messages.   Downstream:    Data direction traveling from a Local Area Network                  (LAN) to a Personal Area Network (PAN) device.   DR:            Demand-Response.  The mechanism of users adjusting                  their power consumption in response to the actual                  pricing of power.   DSM:           Demand-Side Management.  Process allowing power                  utilities to enable and disable loads in consumer                  premises.  Where DR relies on voluntary action from                  users, DSM may be based on enrollment in a formal                  program.   LLNs:          Low-Power and Lossy Networks.   LAN:           Local Area Network.   PAN:           Personal Area Network.  A geographically limited                  wireless network based on, e.g., 802.15.4 or Z-Wave                  radio.   PDA            Personal Digital Assistant.  A small, handheld                  computer.   PLC            Power-Line Communication.   RAM            Random Access Memory.   Sensor:        Network node that measures some physical parameter                  and/or detects an event.  The sensor may generate a                  trap message to notify a controller or directly                  activate an actuator.  If sufficiently powered, sensor                  nodes may participate in routing network messages.   Upstream:      Data direction traveling from a PAN to a LAN device.Brandt, et al.                Informational                     [Page 5]

RFC 5826      Home Automation Routing Requirements in LLNs    April 2010   Refer to the ROLL terminology reference document [ROLL-TERM] for a   full list of terms used in the IETF ROLL WG.1.2.  Requirements Language   The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",   "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this   document are to be interpreted as described inRFC 2119 [RFC2119].2.  Home Automation Applications   Home automation applications represent a special segment of networked   devices with its unique set of requirements.  Historically, such   applications used wired networks or power-line communication (PLC)   but wireless solutions have emerged, allowing existing homes to be   upgraded more easily.   To facilitate the requirements discussion inSection 3, this section   lists a few typical use cases of home automation applications.  New   applications are being developed at a high pace and this section does   not mean to be exhaustive.  Most home automation applications tend to   be running some kind of command/response protocol.  The command may   come from several places.2.1.  Lighting Application in Action   A lamp may be turned on, not only by a wall switch but also by a   movement sensor.  The wall-switch module may itself be a push-button   sensor and an actuator at the same time.  This will often be the case   when upgrading existing homes as existing wiring is not prepared for   automation.   One event may cause many actuators to be activated at the same time.   Using the direct analogy to an electronic car key, a house owner may   activate the "leaving home" function from an electronic house key,   mobile phone, etc.  For the sake of visual impression, all lights   should turn off at the same time; at least, it should appear to   happen at the same time.2.2.  Energy Conservation and Optimizing Energy Consumption   In order to save energy, air conditioning, central heating, window   shades, etc., may be controlled by timers, motion sensors, or   remotely via Internet or cell.  Central heating may also be set to a   reduced temperature during nighttime.Brandt, et al.                Informational                     [Page 6]

RFC 5826      Home Automation Routing Requirements in LLNs    April 2010   The power grid may experience periods where more wind-generated power   is produced than is needed.  Typically this may happen during night   hours.   In periods where electricity demands exceed available supply,   appliances such as air conditioning, climate-control systems, washing   machines, etc., can be turned off to avoid overloading the power   grid.   This is known as Demand-Side Management (DSM).  Remote control of   household appliances is well-suited for this application.   The start/stop decision for the appliances can also be regulated by   dynamic power pricing information obtained from the electricity   utility companies.  This method, called Demand-Response (DR), works   by motivation of users via pricing, bonus points, etc.  For example,   the washing machine and dish washer may just as well work while power   is cheap.  The electric car should also charge its batteries on cheap   power.   In order to achieve effective electricity savings, the energy   monitoring application must guarantee that the power consumption of   the ROLL devices is much lower than that of the appliance itself.   Most of these appliances are mains powered and are thus ideal for   providing reliable, always-on routing resources.  Battery-powered   nodes, by comparison, are constrained routing resources and may only   provide reliable routing under some circumstances.2.3.  Moving a Remote Control Around   A remote control is a typical example of a mobile device in a home   automation network.  An advanced remote control may be used for   dimming the light in the dining room while eating and later on,   turning up the music while doing the dishes in the kitchen.  Reaction   must appear to be instant (within a few hundred milliseconds) even   when the remote control has moved to a new location.  The remote   control may be communicating to either a central home automation   controller or directly to the lamps and the media center.2.4.  Adding a New Module to the System   Small-size, low-cost modules may have no user interface except for a   single button.  Thus, an automated inclusion process is needed for   controllers to find new modules.  Inclusion covers the detection of   neighbors and the assignment of a unique node ID.  Inclusion should   be completed within a few seconds.Brandt, et al.                Informational                     [Page 7]

RFC 5826      Home Automation Routing Requirements in LLNs    April 2010   For ease of use in a consumer application space such as home control,   nodes may be included without having to type in special codes before   inclusion.  One way to achieve an acceptable balance between security   and convenience is to block inclusion during normal operation,   explicitly enable inclusion support just before adding a new module,   and disable it again just after adding a new module.   For security considerations, refer toSection 5.   If assignment of unique addresses is performed by a central   controller, it must be possible to route the inclusion request from   the joining node to the central controller before the joining node   has been included in the network.2.5.  Controlling Battery-Operated Window Shades   In consumer premises, window shades are often battery-powered as   there is no access to mains power over the windows.  For battery   conservation purposes, such an actuator node is sleeping most of the   time.  A controller sending commands to a sleeping actuator node via   ROLL devices will have no problems delivering the packet to the   nearest powered router, but that router may experience a delay until   the next wake-up time before the command can be delivered.2.6.  Remote Video Surveillance   Remote video surveillance is a fairly classic application for home   networking.  It provides the ability for the end-user to get a video   stream from a web cam reached via the Internet.  The video stream may   be triggered by the end-user after receiving an alarm from a sensor   (movement or smoke detector) or the user simply wants to check the   home status via video.   Note that in the former case, more than likely, there will be a form   of inter-device communication: upon detecting some movement in the   home, the movement sensor may send a request to the light controller   to turn on the lights, to the Web Cam to start a video stream that   would then be directed to the end-user's cell phone or Personal   Digital Assistant (PDA) via the Internet.   In contrast to other applications, e.g., industrial sensors, where   data would mainly be originated by a sensor to a sink and vice versa,   this scenario implicates a direct inter-device communication between   ROLL devices.Brandt, et al.                Informational                     [Page 8]

RFC 5826      Home Automation Routing Requirements in LLNs    April 20102.7.  Healthcare   By adding communication capability to devices, patients and elderly   citizens may be able to do simple measurements at home.   Thanks to online devices, a doctor can keep an eye on the patient's   health and receive warnings if a new trend is discovered by automated   filters.   Fine-grained, daily measurements presented in proper ways may allow   the doctor to establish a more precise diagnosis.   Such applications may be realized as wearable products that   frequently do a measurement and automatically deliver the result to a   data sink locally or over the Internet.   Applications falling in this category are referred to as at-home   health reporting.  Whether measurements are done in a fixed interval   or they are manually activated, they leave all processing to the   receiving data sink.   A more active category of applications may send an alarm if some   alarm condition is triggered.  This category of applications is   referred to as at-home health monitoring.  Measurements are   interpreted in the device and may cause reporting of an event if an   alarm is triggered.   Many implementations may overlap both categories.   Since wireless and battery operated systems may never reach 100%   guaranteed operational time, healthcare and security systems will   need a management layer implementing alarm mechanisms for low   battery, report activity, etc.   For instance, if a blood pressure sensor did not report a new   measurement, say five minutes after the scheduled time, some   responsible person must be notified.   The structure and performance of such a management layer is outside   the scope of the routing requirements listed in this document.Brandt, et al.                Informational                     [Page 9]

RFC 5826      Home Automation Routing Requirements in LLNs    April 20102.7.1.  At-Home Health Reporting   Applications might include:   o Temperature   o Weight   o Blood pressure   o Insulin level   Measurements may be stored for long-term statistics.  At the same   time, a critically high blood pressure may cause the generation of an   alarm report.  Refer toSection 2.7.2.   To avoid a high number of request messages, nodes may be configured   to autonomously do a measurement and send a report in intervals.2.7.2.  At-Home Health Monitoring   An alarm event may become active, e.g., if the measured blood   pressure exceeds a threshold or if a person falls to the ground.   Alarm conditions must be reported with the highest priority and   timeliness.   Applications might include:   o Temperature   o Weight   o Blood pressure   o Insulin level   o Electrocardiogram (ECG)   o Position tracker2.8.  Alarm Systems   A home security alarm system is comprised of various sensors   (vibration, fire, carbon monoxide, door/window, glass-break,   presence, panic button, etc.).   Some smoke alarms are battery powered and at the same time mounted in   a high place.  Battery-powered safety devices should only be used for   routing if no other alternatives exist to avoid draining the battery.   A smoke alarm with a drained battery does not provide a lot of   safety.  Also, it may be inconvenient to change the batteries in a   smoke alarm.Brandt, et al.                Informational                    [Page 10]

RFC 5826      Home Automation Routing Requirements in LLNs    April 2010   Alarm system applications may have both a synchronous and an   asynchronous behavior; i.e., they may be periodically queried by a   central control application (e.g., for a periodical refreshment of   the network state) or send a message to the control application on   their own initiative.   When a node (or a group of nodes) identifies a risk situation (e.g.,   intrusion, smoke, fire), it sends an alarm message to a central   controller that could autonomously forward it via the Internet or   interact with other network nodes (e.g., try to obtain more detailed   information or ask other nodes close to the alarm event).   Finally, routing via battery-powered nodes may be very slow if the   nodes are sleeping most of the time (they could appear unresponsive   to the alarm detection).  To ensure fast message delivery and avoid   battery drain, routing should be avoided via sleeping devices.3.  Unique Routing Requirements of Home Automation Applications   Home automation applications have a number of specific routing   requirements related to the set of home networking applications and   the perceived operation of the system.   The relations of use cases to requirements are outlined in the table   below:   +------------------------------+-----------------------------+   | Use case                     | Requirement                 |   +------------------------------+-----------------------------+   |2.1. Lighting Application in  |3.2. Support of Mobility     |   |Action                        |3.3. Scalability             |   +------------------------------+-----------------------------+   |2.2. Energy Conservation and  |3.1. Constraint-Based Routing|   |Optimizing Energy Consumption |                             |   +------------------------------+-----------------------------+   |2.3. Moving a Remote Control  |3.2. Support of Mobility     |   |Around                        |3.4. Convergence Time        |   +------------------------------+-----------------------------+   |2.4. Adding a New Module to   |3.4. Convergence Time        |   |the System                    |3.5. Manageability           |   +------------------------------+-----------------------------+   |2.7. Healthcare               |3.1. Constraint-Based Routing|   |                              |3.2. Support of Mobility     |   |                              |3.4. Convergence Time        |   +------------------------------+-----------------------------+   |2.8. Alarm Systems            |3.3. Scalability             |   |                              |3.4. Convergence Time        |   +------------------------------+-----------------------------+Brandt, et al.                Informational                    [Page 11]

RFC 5826      Home Automation Routing Requirements in LLNs    April 20103.1.  Constraint-Based Routing   For convenience and low-operational costs, power consumption of   consumer products must be kept at a very low level to achieve a long   battery lifetime.  One implication of this fact is that Random Access   Memory (RAM) is limited and it may even be powered down, leaving only   a few 100 bytes of RAM alive during the sleep phase.   The use of battery-powered devices reduces installation costs and   does enable installation of devices even where main power lines are   not available.  On the other hand, in order to be cost effective and   efficient, the devices have to maximize the sleep phase with a duty   cycle lower than 1%.   Some devices only wake up in response to an event, e.g., a push   button.   Simple battery-powered nodes such as movement sensors on garage doors   and rain sensors may not be able to assist in routing.  Depending on   the node type, the node never listens at all, listens rarely, or   makes contact on demand to a pre-configured target node.  Attempting   to communicate with such nodes may at best require a long time before   getting a response.   Other battery-powered nodes may have the capability to participate in   routing.  The routing protocol SHOULD route via mains-powered nodes   if possible.   The routing protocol MUST support constraint-based routing taking   into account node properties (CPU, memory, level of energy, sleep   intervals, safety/convenience of changing battery).3.2.  Support of Mobility   In a home environment, although the majority of devices are fixed   devices, there is still a variety of mobile devices, for example, a   remote control is likely to move.  Another example of mobile devices   is wearable healthcare devices.   While healthcare devices delivering measurement results can tolerate   route discovery times measured in seconds, a remote control appears   unresponsive if using more than 0.5 seconds to, e.g., pause the   music.   On more rare occasions, receiving nodes may also have moved.   Examples include a safety-off switch in a clothes iron, a vacuum   cleaner robot, or the wireless chime of doorbell set.Brandt, et al.                Informational                    [Page 12]

RFC 5826      Home Automation Routing Requirements in LLNs    April 2010   Refer toSection 3.4 for routing protocol convergence times.   A non-responsive node can either be caused by 1) a failure in the   node, 2) a failed link on the path to the node, or 3) a moved node.   In the first two cases, the node can be expected to reappear at   roughly the same location in the network, whereas it can return   anywhere in the network in the latter case.3.3.  Scalability   Looking at the number of wall switches, power outlets, sensors of   various natures, video equipment, and so on in a modern house, it   seems quite realistic that hundreds of devices may form a home-   automation network in a fully populated "smart" home, and a large   proportion of those may be low-power devices.  Moving towards   professional-building automation, the number of such devices may be   in the order of several thousands.   The routing protocol needs to be able to support a basic home   deployment and so MUST be able to support at least 250 devices in the   network.  Furthermore, the protocol SHOULD be extensible to support   more sophisticated and future deployments with a larger number of   devices.3.4.  Convergence Time   A wireless home automation network is subject to various   instabilities due to signal strength variation, moving persons, and   the like.   Measured from the transmission of a packet, the following convergence   time requirements apply.   The routing protocol MUST converge within 0.5 seconds if no nodes   have moved (seeSection 3.2 for motivation).   The routing protocol MUST converge within four seconds if nodes have   moved to re-establish connectivity within a time that a human   operator would find tolerable as, for example, when moving a remote   control unit.   In both cases, "converge" means "the originator node has received a   response from the destination node".  The above-mentioned convergence   time requirements apply to a home control network environment of up   to 250 nodes with up to four repeating nodes between source and   destination.Brandt, et al.                Informational                    [Page 13]

RFC 5826      Home Automation Routing Requirements in LLNs    April 20103.5.  Manageability   The ability of the home network to support auto-configuration is of   the utmost importance.  Indeed, most end-users will not have the   expertise and the skills to perform advanced configuration and   troubleshooting.  Thus, the routing protocol designed for home-   automation networks MUST provide a set of features including zero-   configuration of the routing protocol for a new node to be added to   the network.  From a routing perspective, zero-configuration means   that a node can obtain an address and join the network on its own,   almost without human intervention.3.6.  Stability   If a node is found to fail often compared to the rest of the network,   this node SHOULD NOT be the first choice for routing of traffic.4.  Traffic Pattern   Depending on the design philosophy of the home network, wall switches   may be configured to directly control individual lamps or   alternatively, all wall switches send control commands to a central   lighting control computer, which again sends out control commands to   relevant devices.   In a distributed system, the traffic tends to be multipoint-to-   multipoint.  In a centralized system, it is a mix of multipoint-to-   point and point-to-multipoint.   Wall switches only generate traffic when activated, which typically   happens from one to ten times per hour.   Remote controls have a similar transmit pattern to wall switches but   may be activated more frequently in some deployments.   Temperature/air and pressure/rain sensors send frames when queried by   the user or can be preconfigured to send measurements at fixed   intervals (typically minutes).  Motion sensors typically send a frame   when motion is first detected and another frame when an idle period   with no movement has elapsed.  The highest transmission frequency   depends on the idle period used in the sensor.  Sometimes, a timer   will trigger a frame transmission when an extended period without   status change has elapsed.   All frames sent in the above examples are quite short, typically less   than five bytes of payload.  Lost frames and interference from other   transmitters may lead to retransmissions.  In all cases,   acknowledgment frames with a size of a few bytes are used.Brandt, et al.                Informational                    [Page 14]

RFC 5826      Home Automation Routing Requirements in LLNs    April 20105.  Security Considerations   As is the case with every network, LLNs are exposed to routing   security threats that need to be addressed.  The wireless and   distributed nature of these networks increases the spectrum of   potential routing security threats.  This is further amplified by the   resource constraints of the nodes, thereby preventing resource-   intensive routing security approaches from being deployed.  A viable   routing security approach SHOULD be sufficiently lightweight that it   may be implemented across all nodes in a LLN.  These issues require   special attention during the design process, so as to facilitate a   commercially attractive deployment.   An attacker can snoop, replay, or originate arbitrary messages to a   node in an attempt to manipulate or disable the routing function.   To mitigate this, the LLN MUST be able to authenticate a new node   prior to allowing it to participate in the routing decision process.   The routing protocol MUST support message integrity.   A further example of routing security issues that may arise is the   abnormal behavior of nodes that exhibit an egoistic conduct, such as   not obeying network rules or forwarding no or false packets.   Other important issues may arise in the context of denial-of-service   (DoS) attacks, malicious address space allocations, advertisement of   variable addresses, a wrong neighborhood, etc.  The routing   protocol(s) SHOULD support defense against DoS attacks and other   attempts to maliciously or inadvertently cause the mechanisms of the   routing protocol(s) to over-consume the limited resources of LLN   nodes, e.g., by constructing forwarding loops or causing excessive   routing protocol overhead traffic, etc.   The properties of self-configuration and self-organization that are   desirable in a LLN introduce additional routing security   considerations.  Mechanisms MUST be in place to deny any node that   attempts to take malicious advantage of self-configuration and self-   organization procedures.  Such attacks may attempt, for example, to   cause DoS, drain the energy of power-constrained devices, or to   hijack the routing mechanism.  A node MUST authenticate itself to a   trusted node that is already associated with the LLN before the   former can take part in self-configuration or self-organization.  A   node that has already authenticated and associated with the LLN MUST   deny, to the maximum extent possible, the allocation of resources to   any unauthenticated peer.  The routing protocol(s) MUST deny service   to any node that has not clearly established trust with the HC-LLN.Brandt, et al.                Informational                    [Page 15]

RFC 5826      Home Automation Routing Requirements in LLNs    April 2010   In a home-control environment, it is considered unlikely that a   network is constantly being snooped and at the same time, ease of use   is important.  As a consequence, the network key MAY be exposed for   short periods during inclusion of new nodes.   Electronic door locks and other critical applications SHOULD apply   end-to-end application security on top of the network transport   security.   If connected to a backbone network, the LLN SHOULD be capable of   limiting the resources utilized by nodes in said backbone network so   as not to be vulnerable to DoS.  This should typically be handled by   border routers providing access from a backbone network to resources   in the LLN.   With low-computation power and scarce energy resources, LLNs' nodes   may not be able to resist any attack from high-power malicious nodes   (e.g., laptops and strong radios).  However, the amount of damage   generated to the whole network SHOULD be commensurate with the number   of nodes physically compromised.  For example, an intruder taking   control over a single node SHOULD NOT be able to completely deny   service to the whole network.   In general, the routing protocol(s) SHOULD support the implementation   of routing security best practices across the LLN.  Such an   implementation ought to include defense against, for example,   eavesdropping, replay, message insertion, modification, and man-in-   the-middle attacks.   The choice of the routing security solutions will have an impact on   the routing protocol(s).  To this end, routing protocol(s) proposed   in the context of LLNs MUST support authentication and integrity   measures and SHOULD support confidentiality (routing security)   measures.6.  Acknowledgments   J. P. Vasseur, Jonathan Hui, Eunsook "Eunah" Kim, Mischa Dohler, and   Massimo Maggiorotti are gratefully acknowledged for their   contributions to this document.7.  References7.1.  Normative References   [RFC2119]       Bradner, S., "Key words for use in RFCs to Indicate                   Requirement Levels",BCP 14,RFC 2119, March 1997.Brandt, et al.                Informational                    [Page 16]

RFC 5826      Home Automation Routing Requirements in LLNs    April 20107.2.  Informative References   [BUILDING-REQS] Martocci, J., Ed., De Mil, P., Vermeylen, W., and N.                   Riou, "Building Automation Routing Requirements in                   Low Power and Lossy Networks", Work in Progress,                   January 2010.   [RFC5548]       Dohler, M., Ed., Watteyne, T., Ed., Winter, T., Ed.,                   and D. Barthel, Ed., "Routing Requirements for Urban                   Low-Power and Lossy Networks",RFC 5548, May 2009.   [RFC5673]       Pister, K., Ed., Thubert, P., Ed., Dwars, S., and T.                   Phinney, "Industrial Routing Requirements in Low-                   Power and Lossy Networks",RFC 5673, October 2009.   [ROLL-TERM]     Vasseur, JP. "Terminology in Low power And Lossy                   Networks", Work in Progress, October 2009.Authors' Addresses   Anders Brandt   Sigma Designs, Inc.   Emdrupvej 26   Copenhagen, DK-2100   Denmark   EMail: abr@sdesigns.dk   Jakob Buron   Sigma Designs, Inc.   Emdrupvej 26   Copenhagen, DK-2100   Denmark   EMail: jbu@sdesigns.dk   Giorgio Porcu   Telecom Italia   Piazza degli Affari, 2   20123 Milan   Italy   EMail: gporcu@gmail.comBrandt, et al.                Informational                    [Page 17]