Network Working Group                                      K. McCloghrieRequest for Comments: 2233                                 Cisco SystemsObsoletes:1573                                            F. KastenholzCategory: Standards Track                                   FTP Software                                                           November 1997The Interfaces Group MIB using SMIv2Status of this Memo   This document specifies an Internet standards track protocol for the   Internet community, and requests discussion and suggestions for   improvements.  Please refer to the current edition of the "Internet   Official Protocol Standards" (STD 1) for the standardization state   and status of this protocol.  Distribution of this memo is unlimited.Copyright Notice   Copyright (C) The Internet Society (1997).  All Rights Reserved.Table of Contents1 Introduction ..............................................22 The SNMP Network Management Framework .....................22.1 Object Definitions ......................................33 Experience with the Interfaces Group ......................33.1 Clarifications/Revisions ................................33.1.1 Interface Sub-Layers ..................................43.1.2 Guidance on Defining Sub-layers .......................63.1.3 Virtual Circuits ......................................83.1.4 Bit, Character, and Fixed-Length Interfaces ...........83.1.5 Interface Numbering ...................................103.1.6 Counter Size ..........................................143.1.7 Interface Speed .......................................163.1.8 Multicast/Broadcast Counters ..........................173.1.9 Trap Enable ...........................................183.1.10 Addition of New ifType values ........................183.1.11 InterfaceIndex Textual Convention ....................183.1.12 New states for IfOperStatus ..........................193.1.13 IfAdminStatus and IfOperStatus .......................203.1.14 IfOperStatus in an Interface Stack ...................213.1.15 Traps ................................................213.1.16 ifSpecific ...........................................233.1.17 Creation/Deletion of Interfaces ......................243.1.18 All Values Must be Known .............................244 Media-Specific MIB Applicability ..........................25McCloghrie & Kastenholz     Standards Track                     [Page 1]

RFC 2233            Interfaces Group MIB using SMIv2       November 19975 Overview ..................................................266 Interfaces Group Definitions ..............................267 Acknowledgements ..........................................648 References ................................................649 Security Considerations ...................................6510 Authors' Addresses .......................................6511 Full Copyright Statement .................................661.  Introduction   This memo defines a portion of the Management Information Base   (MIB) for use with network management protocols in the Internet   community.  In particular, it describes managed objects used for   managing Network Interfaces.   This memo discusses the 'interfaces' group of MIB-II, especially the   experience gained from the definition of numerous media- specific MIB   modules for use in conjunction with the 'interfaces' group for   managing various sub-layers beneath the internetwork- layer.  It   specifies clarifications to, and extensions of, the architectural   issues within the previous model used for the 'interfaces' group.   This memo also includes a MIB module.  As well as including new   MIB definitions to support the architectural extensions, this MIB   module also re-specifies the 'interfaces' group of MIB-II in a   manner that is both compliant to the SNMPv2 SMI and semantically-   identical to the existing SNMPv1-based definitions.   The key words "MUST" and "MUST NOT" in this document are to be   interpreted as described inRFC 2119 [10].2.  The SNMP Network Management Framework   The SNMP Network Management Framework presently consists of three   major components.  They are:   oRFC 1902 which defines the SMI, the mechanisms used for        describing and naming objects for the purpose of management.   o    STD 17,RFC 1213 defines MIB-II, the core set of managed        objects for the Internet suite of protocols.   o    STD 15,RFC 1157 andRFC 1905 which define two versions of        the protocol used for network access to managed objects.McCloghrie & Kastenholz     Standards Track                     [Page 2]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997   The Framework permits new objects to be defined for the purpose of   experimentation and evaluation.2.1.  Object Definitions   Managed objects are accessed via a virtual information store,   termed the Management Information Base or MIB.  Objects in the MIB   are defined using the subset of Abstract Syntax Notation One   (ASN.1) defined in the SMI.  In particular, each object object   type is named by an OBJECT IDENTIFIER, an administratively   assigned name.  The object type together with an object instance   serves to uniquely identify a specific instantiation of the   object.  For human convenience, we often use a textual string,   termed the descriptor, to refer to the object type.3.  Experience with the Interfaces Group   One of the strengths of internetwork-layer protocols such as IP   [6] is that they are designed to run over any network interface.   In achieving this, IP considers any and all protocols it runs over   as a single "network interface" layer.  A similar view is taken by   other internetwork-layer protocols.  This concept is represented   in MIB-II by the 'interfaces' group which defines a generic set of   managed objects such that any network interface can be managed in   an interface-independent manner through these managed objects.   The 'interfaces' group provides the means for additional managed   objects specific to particular types of network interface (e.g., a   specific medium such as Ethernet) to be defined as extensions to   the 'interfaces' group for media-specific management.  Since the   standardization of MIB-II, many such media-specific MIB modules   have been defined.   Experience in defining these media-specific MIB modules has shown   that the model defined by MIB-II is too simplistic and/or static   for some types of media-specific management.  As a result, some of   these media-specific MIB modules assume an evolution or loosening   of the model.  This memo documents and standardizes that evolution   of the model and fills in the gaps caused by that evolution.  This   memo also incorporates the interfaces group extensions documented   inRFC 1229 [7].3.1.  Clarifications/Revisions   There are several areas for which experience has indicated that   clarification, revision, or extension of the model would be   helpful.  The following sections discuss the changes in the   interfaces group adopted by this memo in each of these areas.McCloghrie & Kastenholz     Standards Track                     [Page 3]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997   In some sections, one or more paragraphs contain discussion of   rejected alternatives to the model adopted in this memo.  Readers   not familiar with the MIB-II model and not interested in the   rationale behind the new model may want to skip these paragraphs.3.1.1.  Interface Sub-Layers   Experience in defining media-specific management information has   shown the need to distinguish between the multiple sub-layers   beneath the internetwork-layer.  In addition, there is a need to   manage these sub-layers in devices (e.g., MAC-layer bridges) which   are unaware of which, if any, internetwork protocols run over   these sub-layers.  As such, a model of having a single conceptual   row in the interfaces table (MIB-II's ifTable) represent a whole   interface underneath the internetwork-layer, and having a single   associated media-specific MIB module (referenced via the ifType   object) is too simplistic.  A further problem arises with the   value of the ifType object which has enumerated values for each   type of interface.   Consider, for example, an interface with PPP running over an HDLC   link which uses a RS232-like connector.  Each of these sub-layers   has its own media-specific MIB module.  If all of this is   represented by a single conceptual row in the ifTable, then an   enumerated value for ifType is needed for that specific   combination which maps to the specific combination of media-   specific MIBs.  Furthermore, such a model still lacks a method to   describe the relationship of all the sub-layers of the MIB stack.   An associated problem is that of upward and downward multiplexing   of the sub-layers.  An example of upward multiplexing is MLP   (Multi-Link-Procedure) which provides load-sharing over several   serial lines by appearing as a single point-to-point link to the   sub-layer(s) above.  An example of downward multiplexing would be   several instances of PPP, each framed within a separate X.25   virtual circuit, all of which run over one fractional T1 channel,   concurrently with other uses of the T1 link.  The MIB structure   must allow these sorts of relationships to be described.   Several solutions for representing multiple sub-layers were   rejected.  One was to retain the concept of one conceptual row for   all the sub-layers of an interface and have each media-specific   MIB module identify its "superior" and "subordinate" sub-layers   through OBJECT IDENTIFIER "pointers".  This scheme would have   several drawbacks: the superior/subordinate pointers would be   contained in the media-specific MIB modules; thus, a manager could   not learn the structure of an interface without inspecting   multiple pointers in different MIB modules; this would be overlyMcCloghrie & Kastenholz     Standards Track                     [Page 4]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997   complex and only possible if the manager had knowledge of all the   relevant media-specific MIB modules; MIB modules would all need to   be retrofitted with these new "pointers"; this scheme would not   adequately address the problem of upward and downward   multiplexing; and finally, enumerated values of ifType would be   needed for each combination of sub-layers.  Another rejected   solution also retained the concept of one conceptual row for all   the sub-layers of an interface but had a new separate MIB table to   identify the "superior" and "subordinate" sub-layers and to   contain OBJECT IDENTIFIER "pointers" to the media-specific MIB   module for each sub-layer.  Effectively, one conceptual row in the   ifTable would represent each combination of sub-layers between the   internetwork-layer and the wire.  While this scheme has fewer   drawbacks, it still would not support downward multiplexing, such   as PPP over MLP: observe that MLP makes two (or more) serial   lines appear to the layers above as a single physical interface,   and thus PPP over MLP should appear to the internetwork-layer as a   single interface; in contrast, this scheme would result in two (or   more) conceptual rows in the ifTable, both of which the   internetwork-layer would run over.  This scheme would also require   enumerated values of ifType for each combination of sub-layers.   The solution adopted by this memo is to have an individual   conceptual row in the ifTable to represent each sub-layer, and   have a new separate MIB table (the ifStackTable, seesection 6   below) to identify the "superior" and "subordinate" sub-layers   through INTEGER "pointers" to the appropriate conceptual rows in   the ifTable.  This solution supports both upward and downward   multiplexing, allows the IANAifType to Media-Specific MIB mapping   to identify the media-specific MIB module for that sub-layer, such   that the new table need only be referenced to obtain information   about layering, and it only requires enumerated values of ifType   for each sub-layer, not for combinations of them.  However, it   does require that the descriptions of some objects in the ifTable   (specifically, ifType, ifPhysAddress, ifInUcastPkts, and   ifOutUcastPkts) be generalized so as to apply to any sub-layer   (rather than only to a sub-layer immediately beneath the network   layer as previously), plus some (specifically, ifSpeed) which need   to have appropriate values identified for use when a generalized   definition does not apply to a particular sub-layer.   In addition, this adopted solution makes no requirement that a   device, in which a sub-layer is instrumented by a conceptual row   of the ifTable, be aware of whether an internetwork protocol runs   on top of (i.e., at some layer above) that sub-layer.  In fact,   the counters of packets received on an interface are defined as   counting the number "delivered to a higher-layer protocol".  This   meaning of "higher-layer" includes:McCloghrie & Kastenholz     Standards Track                     [Page 5]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997   (1)  Delivery to a forwarding module which accepts        packets/frames/octets and forwards them on at the same        protocol layer.  For example, for the purposes of this        definition, the forwarding module of a MAC-layer bridge is        considered as a "higher-layer" to the MAC-layer of each port        on the bridge.   (2)  Delivery to a higher sub-layer within a interface stack.  For        example, for the purposes of this definition, if a PPP module        operated directly over a serial interface, the PPP module        would be considered the higher sub-layer to the serial        interface.   (3)  Delivery to a higher protocol layer which does not do packet        forwarding for sub-layers that are "at the top of" the        interface stack.  For example, for the purposes of this        definition, the local IP module would be considered the        higher layer to a SLIP serial interface.   Similarly, for output, the counters of packets transmitted out an   interface are defined as counting the number "that higher-level   protocols requested to be transmitted".  This meaning of "higher-   layer" includes:   (1)  A forwarding module, at the same protocol layer, which        transmits packets/frames/octets that were received on an        different interface.  For example, for the purposes of this        definition, the forwarding module of a MAC-layer bridge is        considered as a "higher-layer" to the MAC-layer of each port        on the bridge.   (2)  The next higher sub-layer within an interface stack.  For        example, for the purposes of this definition, if a PPP module        operated directly over a serial interface, the PPP module        would be a "higher layer" to the serial interface.   (3)  For sub-layers that are "at the top of" the interface stack,        a higher element in the network protocol stack.  For example,        for the purposes of this definition, the local IP module        would be considered the higher layer to an Ethernet        interface.3.1.2.  Guidance on Defining Sub-layers   The designer of a media-specific MIB must decide whether to divide   the interface into sub-layers or not, and if so, how to make the   divisions.  The following guidance is offered to assist the   media-specific MIB designer in these decisions.McCloghrie & Kastenholz     Standards Track                     [Page 6]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997   In general, the number of entries in the ifTable should be kept to   the minimum required for network management.  In particular, a   group of related interfaces should be treated as a single   interface with one entry in the ifTable providing that:   (1)  None of the group of interfaces performs multiplexing for any        other interface in the agent,   (2)  There is a meaningful and useful way for all of the ifTable's        information (e.g., the counters, and the status variables),        and all of the ifTable's capabilities (e.g., write access to        ifAdminStatus), to apply to the group of interfaces as a        whole.   Under these circumstances, there should be one entry in the   ifTable for such a group of interfaces, and any internal structure   which needs to be represented to network management should be   captured in a MIB module specific to the particular type of   interface.   Note that application of bullet 2 above to the ifTable's ifType   object requires that there is a meaningful media-specific MIB and   a meaningful ifType value which apply to the group of interfaces   as a whole.  For example, it is not appropriate to treat an HDLC   sub-layer and an RS-232 sub-layer as a single ifTable entry when   the media-specific MIBs and the ifType values for HDLC and RS-232   are separate (rather than combined).   Subject to the above, it is appropriate to assign an ifIndex value   to any interface that can occur in an interface stack (in the   ifStackTable) where the bottom of the stack is a physical   interface (ifConnectorPresent has the value 'true') and there is a   layer-3 or other application that "points down" to the top of this   stack.  An example of an application that points down to the top   of the stack is the Character MIB [9].   Note that the sub-layers of an interface on one device will   sometimes be different from the sub-layers of the interconnected   interface of another device; for example, for a frame-relay DTE   interface connected a frameRelayService interface, the inter-   connected DTE and DCE interfaces have different ifType values and   media-specific MIBs.   These guidelines are just that, guidelines.  The designer of a   media-specific MIB is free to lay out the MIB in whatever SMI   conformant manner is desired.  However, in doing so, the media-   specific MIB MUST completely specify the sub-layering model used   for the MIB, and provide the assumptions, reasoning, and rationale   used to develop that model.McCloghrie & Kastenholz     Standards Track                     [Page 7]

RFC 2233            Interfaces Group MIB using SMIv2       November 19973.1.3.  Virtual Circuits   Several of the sub-layers for which media-specific MIB modules   have been defined are connection oriented (e.g., Frame Relay,   X.25).  Experience has shown that each effort to define such a MIB   module revisits the question of whether separate conceptual rows   in the ifTable are needed for each virtual circuit.  Most, if not   all, of these efforts to date have decided to have all virtual   circuits reference a single conceptual row in the ifTable.   This memo strongly recommends that connection-oriented sub-layers   do not have a conceptual row in the ifTable for each virtual   circuit.  This avoids the proliferation of conceptual rows,   especially those which have considerable redundant information.   (Note, as a comparison, that connection-less sub-layers do not   have conceptual rows for each remote address.)  There may,   however, be circumstances under which it is appropriate for a   virtual circuit of a connection-oriented sub-layer to have its own   conceptual row in the ifTable; an example of this might be PPP   over an X.25 virtual circuit.  The MIB insection 6 of this memo   supports such circumstances.   If a media-specific MIB wishes to assign an entry in the ifTable   to each virtual circuit, the MIB designer must present the   rationale for this decision in the media-specific MIB's   specification.3.1.4.  Bit, Character, and Fixed-Length Interfaces   RS-232 is an example of a character-oriented sub-layer over which   (e.g., through use of PPP) IP datagrams can be sent.  Due to the   packet-based nature of many of the objects in the ifTable,   experience has shown that it is not appropriate to have a   character-oriented sub-layer represented by a whole conceptual row   in the ifTable.   Experience has also shown that it is sometimes desirable to have   some management information for bit-oriented interfaces, which are   similarly difficult to represent by a whole conceptual row in the   ifTable.  For example, to manage the channels of a DS1 circuit,   where only some of the channels are carrying packet-based data.   A further complication is that some subnetwork technologies   transmit data in fixed length transmission units.  One example of   such a technology is cell relay, and in particular Asynchronous   Transfer Mode (ATM), which transmits data in fixed-length cells.   Representing such a interface as a packet-based interface producesMcCloghrie & Kastenholz     Standards Track                     [Page 8]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997   redundant objects if the relationship between the number of   packets and the number of octets in either direction is fixed by   the size of the transmission unit (e.g., the size of a cell).   About half the objects in the ifTable are applicable to every type   of interface: packet-oriented, character-oriented, and bit-   oriented.  Of the other half, two are applicable to both   character-oriented and packet-oriented interfaces, and the rest   are applicable only to packet-oriented interfaces.  Thus, while it   is desirable for consistency to be able to represent any/all types   of interfaces in the ifTable, it is not possible to implement the   full ifTable for bit- and character-oriented sub-layers.   A rejected solution to this problem would be to split the ifTable   into two (or more) new MIB tables, one of which would contain   objects that are relevant only to packet-oriented interfaces   (e.g., PPP), and another that may be used by all interfaces.  This   is highly undesirable since it would require changes in every   agent implementing the ifTable (i.e., just about every existing   SNMP agent).   The solution adopted in this memo builds upon the fact that   compliance statements in SNMPv2 (in contrast to SNMPv1) refer to   object groups, where object groups are explicitly defined by   listing the objects they contain.  Thus, in SNMPv2, multiple   compliance statements can be specified, one for all interfaces and   additional ones for specific types of interfaces.  The separate   compliance statements can be based on separate object groups,   where the object group for all interfaces can contain only those   objects from the ifTable which are appropriate for every type of   interfaces.  Using this solution, every sub-layer can have its own   conceptual row in the ifTable.   Thus,section 6 of this memo contains definitions of the objects   of the existing 'interfaces' group of MIB-II, in a manner which is   both SNMPv2-compliant and semantically-equivalent to the existing   MIB-II definitions.  With equivalent semantics, and with the BER   ("on the wire") encodings unchanged, these definitions retain the   same OBJECT IDENTIFIER values as assigned by MIB-II.  Thus, in   general, no rewrite of existing agents which conform to MIB-II and   the ifExtensions MIB is required.   In addition, this memo defines several object groups for the   purposes of defining which objects apply to which types of   interface:McCloghrie & Kastenholz     Standards Track                     [Page 9]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997   (1)  the ifGeneralInformationGroup.  This group contains those        objects applicable to all types of network interfaces,        including bit-oriented interfaces.   (2)  the ifPacketGroup.  This group contains those objects        applicable to packet-oriented network interfaces.   (3)  the ifFixedLengthGroup.  This group contains the objects        applicable not only to character-oriented interfaces, such as        RS-232, but also to those subnetwork technologies, such as        cell-relay/ATM, which transmit data in fixed length        transmission units.  As well as the octet counters, there are        also a few other counters (e.g., the error counters) which        are useful for this type of interface, but are currently        defined as being packet-oriented.  To accommodate this, the        definitions of these counters are generalized to apply to        character-oriented interfaces and fixed-length-transmission        interfaces.   It should be noted that the octet counters in the ifTable   aggregate octet counts for unicast and non-unicast packets into a   single octet counter per direction (received/transmitted).  Thus,   with the above definition of fixed-length-transmission interfaces,   where such interfaces which support non-unicast packets, separate   counts of unicast and multicast/broadcast transmissions can only   be maintained in a media-specific MIB module.3.1.5.  Interface Numbering   MIB-II defines an object, ifNumber, whose value represents:        "The number of network interfaces (regardless of their        current state) present on this system."   Each interface is identified by a unique value of the ifIndex   object, and the description of ifIndex constrains its value as   follows:        "Its value ranges between 1 and the value of ifNumber.  The        value for each interface must remain constant at least from        one re-initialization of the entity's network management        system to the next re-initialization."   This constancy requirement on the value of ifIndex for a   particular interface is vital for efficient management.  However,   an increasing number of devices allow for the dynamic   addition/removal of network interfaces.  One example of this is a   dynamic ability to configure the use of SLIP/PPP over aMcCloghrie & Kastenholz     Standards Track                    [Page 10]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997   character-oriented port.  For such dynamic additions/removals, the   combination of the constancy requirement and the restriction that   the value of ifIndex is less than ifNumber is problematic.   Redefining ifNumber to be the largest value of ifIndex was   rejected since it would not help.  Such a re-definition would   require ifNumber to be deprecated and the utility of the redefined   object would be questionable.  Alternatively, ifNumber could be   deprecated and not replaced.  However, the deprecation of ifNumber   would require a change to that portion of ifIndex's definition   which refers to ifNumber.  So, since the definition of ifIndex   must be changed anyway in order to solve the problem, changes to   ifNumber do not benefit the solution.   The solution adopted in this memo is just to delete the   requirement that the value of ifIndex must be less than the value   of ifNumber, and to retain ifNumber with its current definition.   This is a minor change in the semantics of ifIndex; however, all   existing agent implementations conform to this new definition, and   in the interests of not requiring changes to existing agent   implementations and to the many existing media-specific MIBs, this   memo assumes that this change does not require ifIndex to be   deprecated.  Experience indicates that this assumption does   "break" a few management applications, but this is considered   preferable to breaking all agent implementations.   This solution also results in the possibility of "holes" in the   ifTable, i.e., the ifIndex values of conceptual rows in the   ifTable are not necessarily contiguous, but SNMP's GetNext (and   SNMPv2's GetBulk) operation easily deals with such holes.  The   value of ifNumber still represents the number of conceptual rows,   which increases/decreases as new interfaces are dynamically   added/removed.   The requirement for constancy (between re-initializations) of an   interface's ifIndex value is met by requiring that after an   interface is dynamically removed, its ifIndex value is not re-used   by a *different* dynamically added interface until after the   following re-initialization of the network management system.   This avoids the need for assignment (in advance) of ifIndex values   for all possible interfaces that might be added dynamically.  The   exact meaning of a "different" interface is hard to define, and   there will be gray areas.  Any firm definition in this document   would likely to turn out to be inadequate.  Instead, implementors   must choose what it means in their particular situation, subject   to the following rules:McCloghrie & Kastenholz     Standards Track                    [Page 11]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997   (1)  a previously-unused value of ifIndex must be assigned to a        dynamically added interface if an agent has no knowledge of        whether the interface is the "same" or "different" to a        previously incarnated interface.   (2)  a management station, not noticing that an interface has gone        away and another has come into existence, must not be        confused when calculating the difference between the counter        values retrieved on successive polls for a particular ifIndex        value.   When the new interface is the same as an old interface, but a   discontinuity in the value of the interface's counters cannot be   avoided, the ifTable has (until now) required that a new ifIndex   value be assigned to the returning interface.  That is, either all   counter values have had to be retained during the absence of an   interface in order to use the same ifIndex value on that   interface's return, or else a new ifIndex value has had to be   assigned to the returning interface.  Both alternatives have   proved to be burdensome to some implementations:   (1)  maintaining the counter values may not be possible (e.g., if        they are maintained on removable hardware),   (2)  using a new ifIndex value presents extra work for management        applications.  While the potential need for such extra work        is unavoidable on agent re-initializations, it is desirable        to avoid it between re-initializations.   To address this, a new object, ifCounterDiscontinuityTime, has   been defined to record the time of the last discontinuity in an   interface's counters.  By monitoring the value of this new object,   a management application can now detect counter discontinuities   without the ifIndex value of the interface being changed.  Thus,   an agent which implements this new object should, when a new   interface is the same as an old interface, retain that interface's   ifIndex value and update if necessary the interface's value of   ifCounterDiscontinuityTime.  With this new object, a management   application must, when calculating differences between counter   values retrieved on successive polls, discard any calculated   difference for which the value of ifCounterDiscontinuityTime is   different for the two polls.  (Note that this test must be   performed in addition to the normal checking of sysUpTime to   detect an agent re-initialization.)  Since such discards are a   waste of network management processing and bandwidth, an agent   should not update the value of ifCounterDiscontinuityTime unless   absolutely necessary.McCloghrie & Kastenholz     Standards Track                    [Page 12]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997   While defining this new object is a change in the semantics of the   ifTable counter objects, it is impractical to deprecate and   redefine all these counters because of their wide deployment and   importance.  Also, a survey of implementations indicates that many   agents and management applications do not correctly implement this   aspect of the current semantics (because of the burdensome issues   mentioned above), such that the practical implications of such a   change is small.  Thus, this breach of the SMI's rules is   considered to be acceptable.   Note, however, that the addition of ifCounterDiscontinuityTime   does not change the fact that:        It is necessary at certain times for the assignment of ifIndex        values to change on a reinitialization of the agent (such as a        reboot).   The possibility of ifIndex value re-assignment must be   accommodated by a management application whenever the value of   sysUpTime is reset to zero.   Note also that some agents support multiple "naming scopes", e.g.,   for an SNMPv1 agent, multiple values of the SNMPv1 community   string.  For such an agent (e.g., a CNM agent which supports a   different subset of interfaces for different customers), there is   no required relationship between the ifIndex values which identify   interfaces in one naming scope and those which identify interfaces   in another naming scope.  It is the agent's choice as to whether   the same or different ifIndex values identify the same or   different interfaces in different naming scopes.   Because of the restriction of the value of ifIndex to be less than   ifNumber, interfaces have been numbered with small integer values.   This has led to the ability by humans to use the ifIndex values as   (somewhat) user-friendly names for network interfaces (e.g.,   "interface number 3").  With the relaxation of the restriction on   the value of ifIndex, there is now the possibility that ifIndex   values could be assigned as very large numbers (e.g., memory   addresses).  Such numbers would be much less user-friendly.   Therefore, this memo recommends that ifIndex values still be   assigned as (relatively) small integer values starting at 1, even   though the values in use at any one time are not necessarily   contiguous.  (Note that this makes remembering which values have   been assigned easy for agents which dynamically add new   interfaces).McCloghrie & Kastenholz     Standards Track                    [Page 13]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997   A new problem is introduced by representing each sub-layer as an   ifTable entry.  Previously, there usually was a simple, direct,   mapping of interfaces to the physical ports on systems.  This   mapping would be based on the ifIndex value.  However, by having   an ifTable entry for each interface sub-layer, mapping from   interfaces to physical ports becomes increasingly problematic.   To address this issue, a new object, ifName, is added to the MIB.   This object contains the device's local name (e.g., the name used   at the device's local console) for the interface of which the   relevant entry in the ifTable is a component.  For example,   consider a router having an interface composed of PPP running over   an RS-232 port.  If the router uses the name "wan1" for the   (combined) interface, then the ifName objects for the   corresponding PPP and RS-232 entries in the ifTable would both   have the value "wan1".  On the other hand, if the router uses the   name "wan1.1" for the PPP interface and "wan1.2" for the RS-232   port, then the ifName objects for the corresponding PPP and RS-232   entries in the ifTable would have the values "wan1.1" and   "wan1.2", respectively.  As an another example, consider an agent   which responds to SNMP queries concerning an interface on some   other (proxied) device: if such a proxied device associates a   particular identifier with an interface, then it is appropriate to   use this identifier as the value of the interface's ifName, since   the local console in this case is that of the proxied device.   In contrast, the existing ifDescr object is intended to contain a   description of an interface, whereas another new object, ifAlias,   provides a location in which a network management application can   store a non-volatile interface-naming value of its own choice.   The ifAlias object allows a network manager to give one or more   interfaces their own unique names, irrespective of any interface-   stack relationship.  Further, the ifAlias name is non-volatile,   and thus an interface must retain its assigned ifAlias value   across reboots, even if an agent chooses a new ifIndex value for   the interface.3.1.6.  Counter Size   As the speed of network media increase, the minimum time in which   a 32 bit counter will wrap decreases.  For example, a 10Mbs stream   of back-to-back, full-size packets causes ifInOctets to wrap in   just over 57 minutes; at 100Mbs, the minimum wrap time is 5.7   minutes, and at 1Gbs, the minimum is 34 seconds.  Requiring that   interfaces be polled frequently enough not to miss a counter wrap   is increasingly problematic.McCloghrie & Kastenholz     Standards Track                    [Page 14]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997   A rejected solution to this problem was to scale the counters; for   example, ifInOctets could be changed to count received octets in,   say, 1024 byte blocks.  While it would provide acceptable   functionality at high rates of the counted-events, at low rates it   suffers.  If there is little traffic on an interface, there might   be a significant interval before enough of the counted-events   occur to cause the scaled counter to be incremented.  Traffic   would then appear to be very bursty, leading to incorrect   conclusions of the network's performance.   Instead, this memo adopts expanded, 64 bit, counters.  These   counters are provided in new "high capacity" groups.  The old,   32-bit, counters have not been deprecated.  The 64-bit counters   are to be used only when the 32-bit counters do not provide enough   capacity; that is, when the 32 bit counters could wrap too fast.   For interfaces that operate at 20,000,000 (20 million) bits per   second or less, 32-bit byte and packet counters MUST be used.  For   interfaces that operate faster than 20,000,000 bits/second, and   slower than 650,000,000 bits/second, 32-bit packet counters MUST   be used and 64-bit octet counters MUST be used.  For interfaces   that operate at 650,000,000 bits/second or faster, 64-bit packet   counters AND 64-bit octet counters MUST be used.   These speed thresholds were chosen as reasonable compromises based   on the following:   (1)  The cost of maintaining 64-bit counters is relatively high,        so minimizing the number of agents which must support them is        desirable.  Common interfaces (such as 10Mbs Ethernet) should        not require them.   (2)  64-bit counters are a new feature, introduced in SNMPv2.  It        is reasonable to expect that support for them will be spotty        for the immediate future.  Thus, we wish to limit them to as        few systems as possible.  This, in effect, means that 64-bit        counters should be limited to higher speed interfaces.        Ethernet (10,000,000 bps) and Token Ring (16,000,000 bps) are        fairly wide-spread so it seems reasonable to not require 64-        bit counters for these interfaces.   (3)  The 32-bit octet counters will wrap in the following times,        for the following interfaces (when transmitting maximum-sized        packets back-to-back):        -   10Mbs Ethernet: 57 minutes,        -   16Mbs Token Ring: 36 minutes,McCloghrie & Kastenholz     Standards Track                    [Page 15]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997        -   a US T3 line (45 megabits): 12 minutes,        -   FDDI: 5.7 minutes   (4)  The 32-bit packet counters wrap in about 57 minutes when 64-        byte packets are transmitted back-to-back on a 650,000,000        bit/second link.   As an aside, a 1-terabit/second (1,000 Gbs) link will cause a 64 bit   octet counter to wrap in just under 5 years.  Conversely, an   81,000,000 terabit/second link is required to cause a 64-bit counter   to wrap in 30 minutes.  We believe that, while technology rapidly   marches forward, this link speed will not be achieved for at least   several years, leaving sufficient time to evaluate the introduction   of 96 bit counters.   When 64-bit counters are in use, the 32-bit counters MUST still be   available.  They will report the low 32-bits of the associated 64-bit   count (e.g., ifInOctets will report the least significant 32 bits of   ifHCInOctets).  This enhances inter-operability with existing   implementations at a very minimal cost to agents.   The new "high capacity" groups are:   (1)  the ifHCFixedLengthGroup for character-oriented/fixed-length        interfaces, and the ifHCPacketGroup for packet-based interfaces;        both of these groups include 64 bit counters for octets, and   (2)  the ifVHCPacketGroup for packet-based interfaces; this group        includes 64 bit counters for octets and packets.3.1.7.  Interface Speed   Network speeds are increasing.  The range of ifSpeed is limited to   reporting a maximum speed of (2**31)-1 bits/second, or approximately   2.2Gbs.  SONET defines an OC-48 interface, which is defined at   operating at 48 times 51 Mbs, which is a speed in excess of 2.4Gbs.   Thus, ifSpeed is insufficient for the future, and this memo defines   an additional object: ifHighSpeed.   The ifHighSpeed object reports the speed of the interface in   1,000,000 (1 million) bits/second units.  Thus, the true speed of the   interface will be the value reported by this object, plus or minus   500,000 bits/second.McCloghrie & Kastenholz     Standards Track                    [Page 16]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997   Other alternatives considered (but rejected) were:   (1)  Making the interface speed a 64-bit gauge.  This was rejected        since the current SMI does not allow such a syntax.        Furthermore, even if 64-bit gauges were available, their use        would require additional complexity in agents due to an        increased requirement for 64-bit operations.   (2)  We also considered making "high-32 bit" and "low-32-bit"        objects which, when combined, would be a 64-bit value.  This        simply seemed overly complex for what we are trying to do.        Furthermore, a full 64-bits of precision does not seem        necessary.  The value of ifHighSpeed will be the only report of        interface speed for interfaces that are faster than        4,294,967,295 bits per second.  At this speed, the granularity        of ifHighSpeed will be 1,000,000 bits per second, thus the error        will be 1/4294, or about 0.02%.  This seems reasonable.   (3)  Adding a "scale" object, which would define the units which        ifSpeed's value is.        This would require two additional objects; one for the scaling        object, and one to replace the current ifSpeed.  This later        object is required since the semantics of ifSpeed would be        significantly altered, and manager stations which do not        understand the new semantics would be confused.3.1.8.  Multicast/Broadcast Counters   In MIB-II, the ifTable counters for multicast and broadcast packets   are combined as counters of non-unicast packets.  In contrast, the   ifExtensions MIB [7] defined one set of counters for multicast, and a   separate set for broadcast packets.  With the separate counters, the   original combined counters become redundant.  To avoid this   redundancy, the non-unicast counters are deprecated.   For the output broadcast and multicast counters defined inRFC 1229,   their definitions varied slightly from the packet counters in the   ifTable, in that they did not count errors/discarded packets.  Thus,   this memo defines new objects with better aligned definitions.   Counters with 64 bits of range are also needed, as explained above.McCloghrie & Kastenholz     Standards Track                    [Page 17]

RFC 2233            Interfaces Group MIB using SMIv2       November 19973.1.9.  Trap Enable   In the multi-layer interface model, each sub-layer for which there is   an entry in the ifTable can generate linkUp/Down Traps.  Since   interface state changes would tend to propagate through the interface   (from top to bottom, or bottom to top), it is likely that several   traps would be generated for each linkUp/Down occurrence.   It is desirable to provide a mechanism for manager stations to   control the generation of these traps.  To this end, the   ifLinkUpDownTrapEnable object has been added.  This object allows   managers to limit generation of traps to just the sub-layers of   interest.   The default setting should limit the number of traps generated to one   per interface per linkUp/Down event.  Furthermore, it seems that the   state changes of most interest to network managers occur at the   lowest level of an interface stack.  Therefore we specify that by   default, only the lowest sub-layer of the interface generate traps.3.1.10.  Addition of New ifType values   Over time, there is the need to add new ifType enumerated values for   new interface types.  If the syntax of ifType were defined in the MIB   insection 6, then a new version of this MIB would have to be re-   issued in order to define new values.  In the past, re- issuing of a   MIB has occurred only after several years.   Therefore, the syntax of ifType is changed to be a textual   convention, such that the enumerated integer values are now defined   in the textual convention, IANAifType, defined in a different   document.  This allows additional values to be documented without   having to re-issue a new version of this document.  The Internet   Assigned Number Authority (IANA) is responsible for the assignment of   all Internet numbers, including various SNMP-related numbers, and   specifically, new ifType values.3.1.11.  InterfaceIndex Textual Convention   A new textual convention, InterfaceIndex, has been defined.  This   textual convention "contains" all of the semantics of the ifIndex   object.  This allows other mib modules to easily import the semantics   of ifIndex.McCloghrie & Kastenholz     Standards Track                    [Page 18]

RFC 2233            Interfaces Group MIB using SMIv2       November 19973.1.12.  New states for IfOperStatus   Three new states have been added to ifOperStatus: 'dormant',   'notPresent', and 'lowerLayerDown'.   The dormant state indicates that the relevant interface is not   actually in a condition to pass packets (i.e., it is not "up") but is   in a "pending" state, waiting for some external event.  For "on-   demand" interfaces, this new state identifies the situation where the   interface is waiting for events to place it in the up state.   Examples of such events might be:   (1)  having packets to transmit before establishing a connection        to a remote system;   (2)  having a remote system establish a connection to the        interface (e.g. dialing up to a slip-server).   The notPresent state is a refinement on the down state which   indicates that the relevant interface is down specifically because   some component (typically, a hardware component) is not present in   the managed system.  Examples of use of the notPresent state are:   (1)  to allow an interface's conceptual row including its counter        values to be retained across a "hot swap" of a card/module,        and/or   (2)  to allow an interface's conceptual row to be created, and        thereby enable interfaces to be pre-configured prior to        installation of the hardware needed to make the interface        operational.   Agents are not required to support interfaces in the notPresent   state.  However, from a conceptual viewpoint, when a row in the   ifTable is created, it first enters the notPresent state and then   subsequently transitions into the down state; similarly, when a row   in the ifTable is deleted, it first enters the notPresent state and   then subsequently the object instances are deleted.  For an agent   with no support for notPresent, both of these transitions (from the   notPresent state to the down state, and from the notPresent state to   the instances being removed) are immediate, i.e., the transition does   not last long enough to be recorded by ifOperStatus.  Even for those   agents which do support interfaces in the notPresent state, the   length of time and conditions under which an interface stays in the   notPresent state is implementation-specific.McCloghrie & Kastenholz     Standards Track                    [Page 19]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997   The lowerLayerDown state is also a refinement on the down state.   This new state indicates that this interface runs "on top of" one or   more other interfaces (see ifStackTable) and that this interface is   down specifically because one or more of these lower-layer interfaces   are down.3.1.13.  IfAdminStatus and IfOperStatus   The down state of ifOperStatus now has two meanings, depending on the   value of ifAdminStatus.   (1)  if ifAdminStatus is not down and ifOperStatus is down then a        fault condition is presumed to exist on the interface.   (2)  if ifAdminStatus is down, then ifOperStatus will normally        also be down (or notPresent) i.e., there is not (necessarily) a        fault condition on the interface.   Note that when ifAdminStatus transitions to down, ifOperStatus will   normally also transition to down.  In this situation, it is possible   that ifOperStatus's transition will not occur immediately, but rather   after a small time lag to complete certain operations before going   "down"; for example, it might need to finish transmitting a packet.   If a manager station finds that ifAdminStatus is down and   ifOperStatus is not down for a particular interface, the manager   station should wait a short while and check again.  If the condition   still exists, only then should it raise an error indication.   Naturally, it should also ensure that ifLastChange has not changed   during this interval.   Whenever an interface table entry is created (usually as a result of   system initialization), the relevant instance of ifAdminStatus is set   to down, and presumably ifOperStatus will be down or notPresent.   An interface may be enabled in two ways: either as a result of   explicit management action (e.g. setting ifAdminStatus to up) or as a   result of the managed system's initialization process.  When   ifAdminStatus changes to the up state, the related ifOperStatus   should do one of the following:   (1)  Change to the up state if and only if the interface is able        to send and receive packets.   (2)  Change to the lowerLayerDown state if and only if the        interface is prevented from entering the up state because of the        state of one or more of the interfaces beneath it in the        interface stack.McCloghrie & Kastenholz     Standards Track                    [Page 20]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997   (3)  Change to the dormant state if and only if the interface is        found to be operable, but the interface is waiting for other,        external, events to occur before it can transmit or receive        packets.  Presumably when the expected events occur, the        interface will then change to the up state.   (4)  Remain in the down state if an error or other fault condition        is detected on the interface.   (5)  Change to the unknown state if, for some reason, the state of        the interface can not be ascertained.   (6)  Change to the testing state if some test(s) must be performed        on the interface. Presumably after completion of the test, the        interface's state will change to up, dormant, or down, as        appropriate.   (7)  Remain in the notPresent state if interface components are        missing.3.1.14.  IfOperStatus in an Interface Stack   When an interface is a part of an interface-stack, but is not the   lowest interface in the stack, then:   (1)  ifOperStatus has the value 'up' if it is able to pass packets        due to one or more interfaces below it in the stack being 'up',        irrespective of whether other interfaces below it are 'down',        'dormant', 'notPresent', 'lowerLayerDown', 'unknown' or        'testing'.   (2)  ifOperStatus may have the value 'up' or 'dormant' if one or        more interfaces below it in the stack are 'dormant', and all        others below it are either 'down', 'dormant', 'notPresent',        'lowerLayerDown', 'unknown' or 'testing'.   (3)  ifOperStatus has the value 'lowerLayerDown' while all        interfaces below it in the stack are either 'down',        'notPresent', 'lowerLayerDown', or 'testing'.3.1.15.  Traps   The exact definition of when linkUp and linkDown traps are generated   has been changed to reflect the changes to ifAdminStatus and   ifOperStatus.McCloghrie & Kastenholz     Standards Track                    [Page 21]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997   Operational experience indicates that management stations are most   concerned with an interface being in the down state and the fact that   this state may indicate a failure.  Thus, it is most useful to   instrument transitions into/out of either the up state or the down   state.   Instrumenting transitions into or out of the up state was rejected   since it would have the drawback that a demand interface might have   many transitions between up and dormant, leading to many linkUp traps   and no linkDown traps.  Furthermore, if a node's only interface is   the demand interface, then a transition to dormant would entail   generation of a linkDown trap, necessitating bringing the link to the   up state (and a linkUp trap)!!   On the other hand, instrumenting transitions into or out of the down   state (to/from all other states except notPresent) has the   advantages:   (1)  A transition into the down state (from a state other than        notPresent) will occur when an error is detected on an        interface.  Error conditions are presumably of great interest to        network managers.   (2)  Departing the down state (to a state other than the        notPresent state) generally indicates that the interface is        going to either up or dormant, both of which are considered        "healthy" states.   Furthermore, it is believed that generating traps on transitions into   or out of the down state (except to/from the notPresent state) is   generally consistent with current usage and interpretation of these   traps by manager stations.   Transitions to/from the notPresent state are concerned with the   insertion and removal of hardware, and are outside the scope of these   traps.   Therefore, this memo defines that LinkUp and linkDown traps are   generated on just after ifOperStatus leaves, or just before it   enters, the down state, respectively; except that LinkUp and linkDown   traps never generated on transitions to/from the notPresent state.   Note that this definition allows a node with only one interface to   transmit a linkDown trap before that interface goes down.  (Of   course, when the interface is going down because of a failure   condition, the linkDown trap probably cannot be successfully   transmitted anyway.)McCloghrie & Kastenholz     Standards Track                    [Page 22]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997   Some interfaces perform a link "training" function when trying to   bring the interface up.  In the event that such an interface were   defective, then the training function would fail and the interface   would remain down, and the training function might be repeated at   appropriate intervals.  If the interface, while performing this   training function, were considered to the in the testing state, then   linkUp and linkDown traps would be generated for each start and end   of the training function.  This is not the intent of the linkUp and   linkDown traps, and therefore, while performing such a training   function, the interface's state should be represented as down.   An exception to the above generation of linkUp/linkDown traps on   changes in ifOperStatus, occurs when an interface is "flapping",   i.e., when it is rapidly oscillating between the up and down states.   If traps were generated for each such oscillation, the network and   the network management system would be flooded with unnecessary   traps.  In such a situation, the agent should rate- limit its   generation of traps.3.1.16.  ifSpecific   The original definition of the OBJECT IDENTIFIER value of ifSpecific   was not sufficiently clear.  As a result, different implementors used   it differently, and confusion resulted.  Some implementations set the   value of ifSpecific to the OBJECT IDENTIFIER that defines the media-   specific MIB, i.e., the "foo" of:              foo OBJECT IDENTIFIER ::= { transmission xxx }   while others set it to be OBJECT IDENTIFIER of the specific table or   entry in the appropriate media-specific MIB (i.e., fooTable or   fooEntry), while still others set it be the OBJECT IDENTIFIER of the   index object of the table's row, including instance identifier,   (i.e., fooIfIndex.ifIndex).  A definition based on the latter would   not be sufficient unless it also allowed for media- specific MIBs   which include several tables, where each table has its own   (different) indexing.   The only definition that can both be made explicit and can cover all   the useful situations is to have ifSpecific be the most general value   for the media-specific MIB module (the first example given above).   This effectively makes it redundant because it contains no more   information than is provided by ifType.  Thus, ifSpecific has been   deprecated.McCloghrie & Kastenholz     Standards Track                    [Page 23]

RFC 2233            Interfaces Group MIB using SMIv2       November 19973.1.17.  Creation/Deletion of Interfaces   While some interfaces, for example, most physical interfaces, cannot   be created via network management, other interfaces such as logical   interfaces sometimes can be.  The ifTable contains only generic   information about an interface.  Almost all 'create-able' interfaces   have other, media-specific, information through which configuration   parameters may be supplied prior to creating such an interface.   Thus, the ifTable does not itself support the creation or deletion of   an interface (specifically, it has no RowStatus [2] column).  Rather,   if a particular interface type supports the dynamic creation and/or   deletion of an interface of that type, then that media-specific MIB   should include an appropriate RowStatus object (see the ATM LAN-   Emulation Client MIB [8] for an example of a MIB which does this).   Typically, when such a RowStatus object is created/deleted, then the   conceptual row in the ifTable appears/disappears as a by-product, and   an ifIndex value (chosen by the agent) is stored in an appropriate   object in the media-specific MIB.3.1.18.  All Values Must be Known   There are a number of situations where an agent does not know the   value of one or more objects for a particular interface.  In all such   circumstances, an agent MUST NOT instantiate an object with an   incorrect value; rather, it MUST respond with the appropriate   error/exception condition (e.g., noSuchInstance for SNMPv2).   One example is where an agent is unable to count the occurrences   defined by one (or more) of the ifTable counters.  In this   circumstance, the agent MUST NOT instantiate the particular counter   with a value of, say, zero.  To do so would be to provide mis-   information to a network management application reading the zero   value, and thereby assuming that there have been no occurrences of   the event (e.g., no input errors because ifInErrors is always zero).   Sometimes the lack of knowledge of an object's value is temporary.   For example, when the MTU of an interface is a configured value and a   device dynamically learns the configured value through (after)   exchanging messages over the interface (e.g., ATM LAN- Emulation   [8]).  In such a case, the value is not known until after the ifTable   entry has already been created.  In such a case, the ifTable entry   should be created without an instance of the object whose value is   unknown; later, when the value becomes known, the missing object can   then be instantiated (e.g., the instance of ifMtu is only   instantiated once the interface's MTU becomes known).McCloghrie & Kastenholz     Standards Track                    [Page 24]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997   As a result of this "known values" rule, management applications MUST   be able to cope with the responses to retrieving the object instances   within a conceptual row of the ifTable revealing that some of the   row's columnar objects are missing/not available.4.  Media-Specific MIB Applicability   The exact use and semantics of many objects in this MIB are open to   some interpretation.  This is a result of the generic nature of this   MIB.  It is not always possible to come up with specific,   unambiguous, text that covers all cases and yet preserves the generic   nature of the MIB.   Therefore, it is incumbent upon a media-specific MIB designer to,   wherever necessary, clarify the use of the objects in this MIB with   respect to the media-specific MIB.   Specific areas of clarification include   Layering Model        The media-specific MIB designer MUST completely and        unambiguously specify the layering model used.  Each individual        sub-layer must be identified, as must the ifStackTable's        portrayal of the relationship(s) between the sub-layers.   Virtual Circuits        The media-specific MIB designer MUST specify whether virtual        circuits are assigned entries in the ifTable or not.  If they        are, compelling rationale must be presented.   ifRcvAddressTable        The media-specific MIB designer MUST specify the applicability        of the ifRcvAddressTable.   ifType        For each of the ifType values to which the media-specific MIB        applies, it must specify the mapping of ifType values to media-        specific MIB module(s) and instances of MIB objects within those        modules.   However, wherever this interface MIB is specific in the semantics,   DESCRIPTION, or applicability of objects, the media-specific MIB   designer MUST NOT change said semantics, DESCRIPTION, or   applicability.McCloghrie & Kastenholz     Standards Track                    [Page 25]

RFC 2233            Interfaces Group MIB using SMIv2       November 19975.  Overview   This MIB consists of 4 tables:   ifTable        This table is the ifTable from MIB-II.        ifXTable        This table contains objects that have been added to the        Interface MIB as a result of the Interface Evolution effort, or        replacements for objects of the original (MIB-II) ifTable that        were deprecated because the semantics of said objects have        significantly changed.  This table also contains objects that        were previously in the ifExtnsTable.   ifStackTable        This table contains objects that define the relationships among        the sub-layers of an interface.   ifRcvAddressTable        This table contains objects that are used to define the media-        level addresses which this interface will receive.  This table        is a generic table.  The designers of media- specific MIBs must        define exactly how this table applies to their specific MIB.6.  Interfaces Group Definitions   IF-MIB DEFINITIONS ::= BEGIN   IMPORTS       MODULE-IDENTITY, OBJECT-TYPE, Counter32, Gauge32, Counter64,       Integer32, TimeTicks, mib-2,       NOTIFICATION-TYPE                        FROM SNMPv2-SMI       TEXTUAL-CONVENTION, DisplayString,       PhysAddress, TruthValue, RowStatus,       TimeStamp, AutonomousType, TestAndIncr   FROM SNMPv2-TC       MODULE-COMPLIANCE, OBJECT-GROUP          FROM SNMPv2-CONF       snmpTraps                                FROM SNMPv2-MIB       IANAifType                               FROM IANAifType-MIB;McCloghrie & Kastenholz     Standards Track                    [Page 26]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997   ifMIB MODULE-IDENTITY       LAST-UPDATED "9611031355Z"       ORGANIZATION "IETF Interfaces MIB Working Group"       CONTACT-INFO               "   Keith McCloghrie                   Cisco Systems, Inc.                   170 West Tasman Drive                   San Jose, CA  95134-1706                   US                   408-526-5260                   kzm@cisco.com"       DESCRIPTION               "The MIB module to describe generic objects for               network interface sub-layers.  This MIB is an updated               version of MIB-II's ifTable, and incorporates the               extensions defined inRFC 1229."       REVISION      "9602282155Z"       DESCRIPTION               "Revisions made by the Interfaces MIB WG."       REVISION      "9311082155Z"       DESCRIPTION               "Initial revision, published as part ofRFC 1573."       ::= { mib-2 31 }   ifMIBObjects OBJECT IDENTIFIER ::= { ifMIB 1 }   interfaces   OBJECT IDENTIFIER ::= { mib-2 2 }   OwnerString ::= TEXTUAL-CONVENTION       DISPLAY-HINT "255a"       STATUS       current       DESCRIPTION               "This data type is used to model an administratively               assigned name of the owner of a resource.  This               information is taken from the NVT ASCII character set.               It is suggested that this name contain one or more of               the following: ASCII form of the manager station's               transport address, management station name (e.g.,               domain name), network management personnel's name,               location, or phone number.  In some cases the agent               itself will be the owner of an entry.  In these cases,               this string shall be set to a string starting with               'agent'."       SYNTAX       OCTET STRING (SIZE(0..255))McCloghrie & Kastenholz     Standards Track                    [Page 27]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997   -- InterfaceIndex contains the semantics of ifIndex and   -- should be used for any objects defined on other mib   -- modules that need these semantics.   InterfaceIndex ::= TEXTUAL-CONVENTION       DISPLAY-HINT "d"       STATUS       current       DESCRIPTION               "A unique value, greater than zero, for each interface               or interface sub-layer in the managed system.  It is               recommended that values are assigned contiguously               starting from 1.  The value for each interface sub-               layer must remain constant at least from one re-               initialization of the entity's network management               system to the next re-initialization."       SYNTAX       Integer32 (1..2147483647)   InterfaceIndexOrZero ::= TEXTUAL-CONVENTION       DISPLAY-HINT "d"       STATUS       current       DESCRIPTION               "This textual convention is an extension of the               InterfaceIndex convention.  The latter defines a               greater than zero value used to identify an interface               or interface sub-layer in the managed system.  This               extension permits the additional value of zero.  the               value zero is object-specific and must therefore be               defined as part of the description of any object which               uses this syntax.  Examples of the usage of zero might               include situations where interface was unknown, or               when none or all interfaces need to be referenced."       SYNTAX       Integer32 (0..2147483647)   ifNumber  OBJECT-TYPE       SYNTAX      Integer32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "The number of network interfaces (regardless of their               current state) present on this system."       ::= { interfaces 1 }McCloghrie & Kastenholz     Standards Track                    [Page 28]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997   ifTableLastChange  OBJECT-TYPE       SYNTAX      TimeTicks       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "The value of sysUpTime at the time of the last               creation or deletion of an entry in the ifTable.  If               the number of entries has been unchanged since the               last re-initialization of the local network management               subsystem, then this object contains a zero value."       ::= { ifMIBObjects 5 }   -- the Interfaces table   -- The Interfaces table contains information on the entity's   -- interfaces.  Each sub-layer below the internetwork-layer   -- of a network interface is considered to be an interface.   ifTable OBJECT-TYPE       SYNTAX      SEQUENCE OF IfEntry       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION               "A list of interface entries.  The number of entries               is given by the value of ifNumber."       ::= { interfaces 2 }   ifEntry OBJECT-TYPE       SYNTAX      IfEntry       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION               "An entry containing management information applicable               to a particular interface."       INDEX   { ifIndex }       ::= { ifTable 1 }   IfEntry ::=       SEQUENCE {           ifIndex                 InterfaceIndex,           ifDescr                 DisplayString,           ifType                  IANAifType,           ifMtu                   Integer32,           ifSpeed                 Gauge32,McCloghrie & Kastenholz     Standards Track                    [Page 29]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997           ifPhysAddress           PhysAddress,           ifAdminStatus           INTEGER,           ifOperStatus            INTEGER,           ifLastChange            TimeTicks,           ifInOctets              Counter32,           ifInUcastPkts           Counter32,           ifInNUcastPkts          Counter32,  -- deprecated           ifInDiscards            Counter32,           ifInErrors              Counter32,           ifInUnknownProtos       Counter32,           ifOutOctets             Counter32,           ifOutUcastPkts          Counter32,           ifOutNUcastPkts         Counter32,  -- deprecated           ifOutDiscards           Counter32,           ifOutErrors             Counter32,           ifOutQLen               Gauge32,    -- deprecated           ifSpecific              OBJECT IDENTIFIER -- deprecated       }   ifIndex OBJECT-TYPE       SYNTAX      InterfaceIndex       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "A unique value, greater than zero, for each               interface.  It is recommended that values are assigned               contiguously starting from 1.  The value for each               interface sub-layer must remain constant at least from               one re-initialization of the entity's network               management system to the next re-initialization."       ::= { ifEntry 1 }   ifDescr OBJECT-TYPE       SYNTAX      DisplayString (SIZE (0..255))       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "A textual string containing information about the               interface.  This string should include the name of the               manufacturer, the product name and the version of the               interface hardware/software."       ::= { ifEntry 2 }McCloghrie & Kastenholz     Standards Track                    [Page 30]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997   ifType OBJECT-TYPE       SYNTAX      IANAifType       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "The type of interface.  Additional values for ifType               are assigned by the Internet Assigned Numbers               Authority (IANA), through updating the syntax of the               IANAifType textual convention."       ::= { ifEntry 3 }   ifMtu OBJECT-TYPE       SYNTAX      Integer32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "The size of the largest packet which can be               sent/received on the interface, specified in octets.               For interfaces that are used for transmitting network               datagrams, this is the size of the largest network               datagram that can be sent on the interface."       ::= { ifEntry 4 }   ifSpeed OBJECT-TYPE       SYNTAX      Gauge32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "An estimate of the interface's current bandwidth in               bits per second.  For interfaces which do not vary in               bandwidth or for those where no accurate estimation               can be made, this object should contain the nominal               bandwidth.  If the bandwidth of the interface is               greater than the maximum value reportable by this               object then this object should report its maximum               value (4,294,967,295) and ifHighSpeed must be used to               report the interace's speed.  For a sub-layer which               has no concept of bandwidth, this object should be               zero."       ::= { ifEntry 5 }   ifPhysAddress OBJECT-TYPE       SYNTAX      PhysAddress       MAX-ACCESS  read-only       STATUS      currentMcCloghrie & Kastenholz     Standards Track                    [Page 31]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997       DESCRIPTION               "The interface's address at its protocol sub-layer.               For example, for an 802.x interface, this object               normally contains a MAC address.  The interface's               media-specific MIB must define the bit and byte               ordering and the format of the value of this object.               For interfaces which do not have such an address               (e.g., a serial line), this object should contain an               octet string of zero length."       ::= { ifEntry 6 }   ifAdminStatus OBJECT-TYPE       SYNTAX  INTEGER {                   up(1),       -- ready to pass packets                   down(2),                   testing(3)   -- in some test mode               }       MAX-ACCESS  read-write       STATUS      current       DESCRIPTION               "The desired state of the interface.  The testing(3)               state indicates that no operational packets can be               passed.  When a managed system initializes, all               interfaces start with ifAdminStatus in the down(2)               state.  As a result of either explicit management               action or per configuration information retained by               the managed system, ifAdminStatus is then changed to               either the up(1) or testing(3) states (or remains in               the down(2) state)."       ::= { ifEntry 7 }   ifOperStatus OBJECT-TYPE       SYNTAX  INTEGER {                   up(1),        -- ready to pass packets                   down(2),                   testing(3),   -- in some test mode                   unknown(4),   -- status can not be determined                                 -- for some reason.                   dormant(5),                   notPresent(6),    -- some component is missing                   lowerLayerDown(7) -- down due to state of                                     -- lower-layer interface(s)               }McCloghrie & Kastenholz     Standards Track                    [Page 32]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "The current operational state of the interface.  The               testing(3) state indicates that no operational packets               can be passed.  If ifAdminStatus is down(2) then               ifOperStatus should be down(2).  If ifAdminStatus is               changed to up(1) then ifOperStatus should change to               up(1) if the interface is ready to transmit and               receive network traffic; it should change to               dormant(5) if the interface is waiting for external               actions (such as a serial line waiting for an incoming               connection); it should remain in the down(2) state if               and only if there is a fault that prevents it from               going to the up(1) state; it should remain in the               notPresent(6) state if the interface has missing               (typically, hardware) components."       ::= { ifEntry 8 }   ifLastChange OBJECT-TYPE       SYNTAX      TimeTicks       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "The value of sysUpTime at the time the interface               entered its current operational state.  If the current               state was entered prior to the last re-initialization               of the local network management subsystem, then this               object contains a zero value."       ::= { ifEntry 9 }   ifInOctets OBJECT-TYPE       SYNTAX      Counter32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "The total number of octets received on the interface,               including framing characters.               Discontinuities in the value of this counter can occur               at re-initialization of the management system, and at               other times as indicated by the value of               ifCounterDiscontinuityTime."       ::= { ifEntry 10 }McCloghrie & Kastenholz     Standards Track                    [Page 33]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997   ifInUcastPkts OBJECT-TYPE       SYNTAX      Counter32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "The number of packets, delivered by this sub-layer to               a higher (sub-)layer, which were not addressed to a               multicast or broadcast address at this sub-layer.               Discontinuities in the value of this counter can occur               at re-initialization of the management system, and at               other times as indicated by the value of               ifCounterDiscontinuityTime."       ::= { ifEntry 11 }   ifInNUcastPkts OBJECT-TYPE       SYNTAX  Counter32       MAX-ACCESS  read-only       STATUS      deprecated       DESCRIPTION               "The number of packets, delivered by this sub-layer to               a higher (sub-)layer, which were addressed to a               multicast or broadcast address at this sub-layer.               Discontinuities in the value of this counter can occur               at re-initialization of the management system, and at               other times as indicated by the value of               ifCounterDiscontinuityTime.               This object is deprecated in favour of               ifInMulticastPkts and ifInBroadcastPkts."       ::= { ifEntry 12 }   ifInDiscards OBJECT-TYPE       SYNTAX      Counter32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "The number of inbound packets which were chosen to be               discarded even though no errors had been detected to               prevent their being deliverable to a higher-layer               protocol.  One possible reason for discarding such a               packet could be to free up buffer space.               Discontinuities in the value of this counter can occur               at re-initialization of the management system, and at               other times as indicated by the value of               ifCounterDiscontinuityTime."McCloghrie & Kastenholz     Standards Track                    [Page 34]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997       ::= { ifEntry 13 }   ifInErrors OBJECT-TYPE       SYNTAX      Counter32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "For packet-oriented interfaces, the number of inbound               packets that contained errors preventing them from               being deliverable to a higher-layer protocol.  For               character-oriented or fixed-length interfaces, the               number of inbound transmission units that contained               errors preventing them from being deliverable to a               higher-layer protocol.               Discontinuities in the value of this counter can occur               at re-initialization of the management system, and at               other times as indicated by the value of               ifCounterDiscontinuityTime."       ::= { ifEntry 14 }   ifInUnknownProtos OBJECT-TYPE       SYNTAX      Counter32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "For packet-oriented interfaces, the number of packets               received via the interface which were discarded               because of an unknown or unsupported protocol.  For               character-oriented or fixed-length interfaces that               support protocol multiplexing the number of               transmission units received via the interface which               were discarded because of an unknown or unsupported               protocol.  For any interface that does not support               protocol multiplexing, this counter will always be 0.               Discontinuities in the value of this counter can occur               at re-initialization of the management system, and at               other times as indicated by the value of               ifCounterDiscontinuityTime."       ::= { ifEntry 15 }McCloghrie & Kastenholz     Standards Track                    [Page 35]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997   ifOutOctets OBJECT-TYPE       SYNTAX      Counter32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "The total number of octets transmitted out of the               interface, including framing characters.               Discontinuities in the value of this counter can occur               at re-initialization of the management system, and at               other times as indicated by the value of               ifCounterDiscontinuityTime."       ::= { ifEntry 16 }   ifOutUcastPkts OBJECT-TYPE       SYNTAX      Counter32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "The total number of packets that higher-level               protocols requested be transmitted, and which were not               addressed to a multicast or broadcast address at this               sub-layer, including those that were discarded or not               sent.               Discontinuities in the value of this counter can occur               at re-initialization of the management system, and at               other times as indicated by the value of               ifCounterDiscontinuityTime."       ::= { ifEntry 17 }   ifOutNUcastPkts OBJECT-TYPE       SYNTAX      Counter32       MAX-ACCESS  read-only       STATUS      deprecated       DESCRIPTION               "The total number of packets that higher-level               protocols requested be transmitted, and which were               addressed to a multicast or broadcast address at this               sub-layer, including those that were discarded or not               sent.               Discontinuities in the value of this counter can occur               at re-initialization of the management system, and at               other times as indicated by the value of               ifCounterDiscontinuityTime.McCloghrie & Kastenholz     Standards Track                    [Page 36]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997               This object is deprecated in favour of               ifOutMulticastPkts and ifOutBroadcastPkts."       ::= { ifEntry 18 }   ifOutDiscards OBJECT-TYPE       SYNTAX      Counter32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "The number of outbound packets which were chosen to               be discarded even though no errors had been detected               to prevent their being transmitted.  One possible               reason for discarding such a packet could be to free               up buffer space.               Discontinuities in the value of this counter can occur               at re-initialization of the management system, and at               other times as indicated by the value of               ifCounterDiscontinuityTime."       ::= { ifEntry 19 }   ifOutErrors OBJECT-TYPE       SYNTAX      Counter32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "For packet-oriented interfaces, the number of               outbound packets that could not be transmitted because               of errors.  For character-oriented or fixed-length               interfaces, the number of outbound transmission units               that could not be transmitted because of errors.               Discontinuities in the value of this counter can occur               at re-initialization of the management system, and at               other times as indicated by the value of               ifCounterDiscontinuityTime."       ::= { ifEntry 20 }   ifOutQLen OBJECT-TYPE       SYNTAX      Gauge32       MAX-ACCESS  read-only       STATUS      deprecated       DESCRIPTION               "The length of the output packet queue (in packets)."       ::= { ifEntry 21 }McCloghrie & Kastenholz     Standards Track                    [Page 37]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997   ifSpecific OBJECT-TYPE       SYNTAX      OBJECT IDENTIFIER       MAX-ACCESS  read-only       STATUS      deprecated       DESCRIPTION               "A reference to MIB definitions specific to the               particular media being used to realize the interface.               It is recommended that this value point to an instance               of a MIB object in the media-specific MIB, i.e., that               this object have the semantics associated with the               InstancePointer textual convention defined inRFC1903.  In fact, it is recommended that the media-               specific MIB specify what value ifSpecific should/can               take for values of ifType.  If no MIB definitions               specific to the particular media are available, the               value should be set to the OBJECT IDENTIFIER { 0 0 }."       ::= { ifEntry 22 }   --   --   Extension to the interface table   --   -- This table replaces the ifExtnsTable table.   --   ifXTable        OBJECT-TYPE       SYNTAX      SEQUENCE OF IfXEntry       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION               "A list of interface entries.  The number of entries               is given by the value of ifNumber.  This table               contains additional objects for the interface table."       ::= { ifMIBObjects 1 }   ifXEntry        OBJECT-TYPE       SYNTAX      IfXEntry       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION               "An entry containing additional management information               applicable to a particular interface."       AUGMENTS    { ifEntry }       ::= { ifXTable 1 }McCloghrie & Kastenholz     Standards Track                    [Page 38]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997   IfXEntry ::=       SEQUENCE {           ifName                  DisplayString,           ifInMulticastPkts       Counter32,           ifInBroadcastPkts       Counter32,           ifOutMulticastPkts      Counter32,           ifOutBroadcastPkts      Counter32,           ifHCInOctets            Counter64,           ifHCInUcastPkts         Counter64,           ifHCInMulticastPkts     Counter64,           ifHCInBroadcastPkts     Counter64,           ifHCOutOctets           Counter64,           ifHCOutUcastPkts        Counter64,           ifHCOutMulticastPkts    Counter64,           ifHCOutBroadcastPkts    Counter64,           ifLinkUpDownTrapEnable  INTEGER,           ifHighSpeed             Gauge32,           ifPromiscuousMode       TruthValue,           ifConnectorPresent      TruthValue,           ifAlias                 DisplayString,           ifCounterDiscontinuityTime TimeStamp       }   ifName OBJECT-TYPE       SYNTAX      DisplayString       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "The textual name of the interface.  The value of this               object should be the name of the interface as assigned               by the local device and should be suitable for use in               commands entered at the device's `console'.  This               might be a text name, such as `le0' or a simple port               number, such as `1', depending on the interface naming               syntax of the device.  If several entries in the               ifTable together represent a single interface as named               by the device, then each will have the same value of               ifName.  Note that for an agent which responds to SNMP               queries concerning an interface on some other               (proxied) device, then the value of ifName for such an               interface is the proxied device's local name for it.               If there is no local name, or this object is otherwise               not applicable, then this object contains a zero-               length string."       ::= { ifXEntry 1 }McCloghrie & Kastenholz     Standards Track                    [Page 39]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997   ifInMulticastPkts OBJECT-TYPE       SYNTAX      Counter32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "The number of packets, delivered by this sub-layer to               a higher (sub-)layer, which were addressed to a               multicast address at this sub-layer.  For a MAC layer               protocol, this includes both Group and Functional               addresses.               Discontinuities in the value of this counter can occur               at re-initialization of the management system, and at               other times as indicated by the value of               ifCounterDiscontinuityTime."       ::= { ifXEntry 2 }   ifInBroadcastPkts OBJECT-TYPE       SYNTAX      Counter32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "The number of packets, delivered by this sub-layer to               a higher (sub-)layer, which were addressed to a               broadcast address at this sub-layer.               Discontinuities in the value of this counter can occur               at re-initialization of the management system, and at               other times as indicated by the value of               ifCounterDiscontinuityTime."       ::= { ifXEntry 3 }   ifOutMulticastPkts OBJECT-TYPE       SYNTAX      Counter32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "The total number of packets that higher-level               protocols requested be transmitted, and which were               addressed to a multicast address at this sub-layer,               including those that were discarded or not sent.  For               a MAC layer protocol, this includes both Group and               Functional addresses.               Discontinuities in the value of this counter can occur               at re-initialization of the management system, and at               other times as indicated by the value of               ifCounterDiscontinuityTime."McCloghrie & Kastenholz     Standards Track                    [Page 40]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997       ::= { ifXEntry 4 }   ifOutBroadcastPkts OBJECT-TYPE       SYNTAX      Counter32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "The total number of packets that higher-level               protocols requested be transmitted, and which were               addressed to a broadcast address at this sub-layer,               including those that were discarded or not sent.               Discontinuities in the value of this counter can occur               at re-initialization of the management system, and at               other times as indicated by the value of               ifCounterDiscontinuityTime."       ::= { ifXEntry 5 }   --   -- High Capacity Counter objects.  These objects are all   -- 64 bit versions of the "basic" ifTable counters.  These   -- objects all have the same basic semantics as their 32-bit   -- counterparts, however, their syntax has been extended   -- to 64 bits.   --   ifHCInOctets OBJECT-TYPE       SYNTAX      Counter64       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "The total number of octets received on the interface,               including framing characters.  This object is a 64-bit               version of ifInOctets.               Discontinuities in the value of this counter can occur               at re-initialization of the management system, and at               other times as indicated by the value of               ifCounterDiscontinuityTime."       ::= { ifXEntry 6 }McCloghrie & Kastenholz     Standards Track                    [Page 41]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997   ifHCInUcastPkts OBJECT-TYPE       SYNTAX      Counter64       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "The number of packets, delivered by this sub-layer to               a higher (sub-)layer, which were not addressed to a               multicast or broadcast address at this sub-layer.               This object is a 64-bit version of ifInUcastPkts.               Discontinuities in the value of this counter can occur               at re-initialization of the management system, and at               other times as indicated by the value of               ifCounterDiscontinuityTime."       ::= { ifXEntry 7 }   ifHCInMulticastPkts OBJECT-TYPE       SYNTAX      Counter64       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "The number of packets, delivered by this sub-layer to               a higher (sub-)layer, which were addressed to a               multicast address at this sub-layer.  For a MAC layer               protocol, this includes both Group and Functional               addresses.  This object is a 64-bit version of               ifInMulticastPkts.               Discontinuities in the value of this counter can occur               at re-initialization of the management system, and at               other times as indicated by the value of               ifCounterDiscontinuityTime."       ::= { ifXEntry 8 }   ifHCInBroadcastPkts OBJECT-TYPE       SYNTAX      Counter64       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "The number of packets, delivered by this sub-layer to               a higher (sub-)layer, which were addressed to a               broadcast address at this sub-layer.  This object is a               64-bit version of ifInBroadcastPkts.               Discontinuities in the value of this counter can occur               at re-initialization of the management system, and at               other times as indicated by the value ofMcCloghrie & Kastenholz     Standards Track                    [Page 42]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997               ifCounterDiscontinuityTime."       ::= { ifXEntry 9 }   ifHCOutOctets OBJECT-TYPE       SYNTAX      Counter64       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "The total number of octets transmitted out of the               interface, including framing characters.  This object               is a 64-bit version of ifOutOctets.               Discontinuities in the value of this counter can occur               at re-initialization of the management system, and at               other times as indicated by the value of               ifCounterDiscontinuityTime."       ::= { ifXEntry 10 }   ifHCOutUcastPkts OBJECT-TYPE       SYNTAX      Counter64       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "The total number of packets that higher-level               protocols requested be transmitted, and which were not               addressed to a multicast or broadcast address at this               sub-layer, including those that were discarded or not               sent.  This object is a 64-bit version of               ifOutUcastPkts.               Discontinuities in the value of this counter can occur               at re-initialization of the management system, and at               other times as indicated by the value of               ifCounterDiscontinuityTime."       ::= { ifXEntry 11 }   ifHCOutMulticastPkts OBJECT-TYPE       SYNTAX      Counter64       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "The total number of packets that higher-level               protocols requested be transmitted, and which were               addressed to a multicast address at this sub-layer,               including those that were discarded or not sent.  For               a MAC layer protocol, this includes both Group and               Functional addresses.  This object is a 64-bit version               of ifOutMulticastPkts.McCloghrie & Kastenholz     Standards Track                    [Page 43]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997               Discontinuities in the value of this counter can occur               at re-initialization of the management system, and at               other times as indicated by the value of               ifCounterDiscontinuityTime."       ::= { ifXEntry 12 }   ifHCOutBroadcastPkts OBJECT-TYPE       SYNTAX      Counter64       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "The total number of packets that higher-level               protocols requested be transmitted, and which were               addressed to a broadcast address at this sub-layer,               including those that were discarded or not sent.  This               object is a 64-bit version of ifOutBroadcastPkts.               Discontinuities in the value of this counter can occur               at re-initialization of the management system, and at               other times as indicated by the value of               ifCounterDiscontinuityTime."       ::= { ifXEntry 13 }   ifLinkUpDownTrapEnable  OBJECT-TYPE       SYNTAX      INTEGER { enabled(1), disabled(2) }       MAX-ACCESS  read-write       STATUS      current       DESCRIPTION               "Indicates whether linkUp/linkDown traps should be               generated for this interface.               By default, this object should have the value               enabled(1) for interfaces which do not operate on               'top' of any other interface (as defined in the               ifStackTable), and disabled(2) otherwise."       ::= { ifXEntry 14 }   ifHighSpeed OBJECT-TYPE       SYNTAX      Gauge32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "An estimate of the interface's current bandwidth in               units of 1,000,000 bits per second.  If this object               reports a value of `n' then the speed of the interface               is somewhere in the range of `n-500,000' to               `n+499,999'.  For interfaces which do not vary inMcCloghrie & Kastenholz     Standards Track                    [Page 44]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997               bandwidth or for those where no accurate estimation               can be made, this object should contain the nominal               bandwidth.  For a sub-layer which has no concept of               bandwidth, this object should be zero."       ::= { ifXEntry 15 }   ifPromiscuousMode  OBJECT-TYPE       SYNTAX      TruthValue       MAX-ACCESS  read-write       STATUS      current       DESCRIPTION               "This object has a value of false(2) if this interface               only accepts packets/frames that are addressed to this               station.  This object has a value of true(1) when the               station accepts all packets/frames transmitted on the               media.  The value true(1) is only legal on certain               types of media.  If legal, setting this object to a               value of true(1) may require the interface to be reset               before becoming effective.               The value of ifPromiscuousMode does not affect the               reception of broadcast and multicast packets/frames by               the interface."       ::= { ifXEntry 16 }   ifConnectorPresent   OBJECT-TYPE       SYNTAX      TruthValue       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "This object has the value 'true(1)' if the interface               sublayer has a physical connector and the value               'false(2)' otherwise."       ::= { ifXEntry 17 }   ifAlias   OBJECT-TYPE       SYNTAX      DisplayString (SIZE(0..64))       MAX-ACCESS  read-write       STATUS      current       DESCRIPTION               "This object is an 'alias' name for the interface as               specified by a network manager, and provides a non-               volatile 'handle' for the interface.               On the first instantiation of an interface, the value               of ifAlias associated with that interface is the               zero-length string.  As and when a value is written               into an instance of ifAlias through a networkMcCloghrie & Kastenholz     Standards Track                    [Page 45]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997               management set operation, then the agent must retain               the supplied value in the ifAlias instance associated               with the same interface for as long as that interface               remains instantiated, including across all re-               initializations/reboots of the network management               system, including those which result in a change of               the interface's ifIndex value.               An example of the value which a network manager might               store in this object for a WAN interface is the               (Telco's) circuit number/identifier of the interface.               Some agents may support write-access only for               interfaces having particular values of ifType.  An               agent which supports write access to this object is               required to keep the value in non-volatile storage,               but it may limit the length of new values depending on               how much storage is already occupied by the current               values for other interfaces."       ::= { ifXEntry 18 }   ifCounterDiscontinuityTime OBJECT-TYPE       SYNTAX      TimeStamp       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "The value of sysUpTime on the most recent occasion at               which any one or more of this interface's counters               suffered a discontinuity.  The relevant counters are               the specific instances associated with this interface               of any Counter32 or Counter64 object contained in the               ifTable or ifXTable.  If no such discontinuities have               occurred since the last re-initialization of the local               management subsystem, then this object contains a zero               value."       ::= { ifXEntry 19 }   --           The Interface Stack Group   --   -- Implementation of this group is mandatory for all systems   --   ifStackTable  OBJECT-TYPE        SYNTAX        SEQUENCE OF IfStackEntry        MAX-ACCESS    not-accessible        STATUS        current        DESCRIPTIONMcCloghrie & Kastenholz     Standards Track                    [Page 46]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997               "The table containing information on the relationships               between the multiple sub-layers of network interfaces.               In particular, it contains information on which sub-               layers run 'on top of' which other sub-layers, where               each sub-layer corresponds to a conceptual row in the               ifTable.  For example, when the sub-layer with ifIndex               value x runs over the sub-layer with ifIndex value y,               then this table contains:                 ifStackStatus.x.y=active               For each ifIndex value, I, which identifies an active               interface, there are always at least two instantiated               rows in this table associated with I.  For one of               these rows, I is the value of ifStackHigherLayer; for               the other, I is the value of ifStackLowerLayer.  (If I               is not involved in multiplexing, then these are the               only two rows associated with I.)               For example, two rows exist even for an interface               which has no others stacked on top or below it:                 ifStackStatus.0.x=active                 ifStackStatus.x.0=active "        ::= { ifMIBObjects 2 }   ifStackEntry  OBJECT-TYPE        SYNTAX        IfStackEntry        MAX-ACCESS    not-accessible        STATUS        current        DESCRIPTION               "Information on a particular relationship between two               sub-layers, specifying that one sub-layer runs on               'top' of the other sub-layer.  Each sub-layer               corresponds to a conceptual row in the ifTable."        INDEX { ifStackHigherLayer, ifStackLowerLayer }        ::= { ifStackTable 1 }   IfStackEntry ::=       SEQUENCE {           ifStackHigherLayer  Integer32,           ifStackLowerLayer   Integer32,           ifStackStatus       RowStatus        }McCloghrie & Kastenholz     Standards Track                    [Page 47]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997   ifStackHigherLayer  OBJECT-TYPE        SYNTAX        Integer32        MAX-ACCESS    not-accessible        STATUS        current        DESCRIPTION               "The value of ifIndex corresponding to the higher               sub-layer of the relationship, i.e., the sub-layer               which runs on 'top' of the sub-layer identified by the               corresponding instance of ifStackLowerLayer.  If there               is no higher sub-layer (below the internetwork layer),               then this object has the value 0."        ::= { ifStackEntry 1 }   ifStackLowerLayer  OBJECT-TYPE        SYNTAX        Integer32        MAX-ACCESS    not-accessible        STATUS        current        DESCRIPTION               "The value of ifIndex corresponding to the lower sub-               layer of the relationship, i.e., the sub-layer which               runs 'below' the sub-layer identified by the               corresponding instance of ifStackHigherLayer.  If               there is no lower sub-layer, then this object has the               value 0."        ::= { ifStackEntry 2 }   ifStackStatus  OBJECT-TYPE       SYNTAX         RowStatus       MAX-ACCESS     read-create       STATUS         current       DESCRIPTION               "The status of the relationship between two sub-               layers.               Changing the value of this object from 'active' to               'notInService' or 'destroy' will likely have               consequences up and down the interface stack.  Thus,               write access to this object is likely to be               inappropriate for some types of interfaces, and many               implementations will choose not to support write-               access for any type of interface."       ::= { ifStackEntry 3 }   ifStackLastChange OBJECT-TYPE       SYNTAX         TimeTicks       MAX-ACCESS     read-onlyMcCloghrie & Kastenholz     Standards Track                    [Page 48]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997       STATUS         current       DESCRIPTION               "The value of sysUpTime at the time of the last change               of the (whole) interface stack.  A change of the               interface stack is defined to be any creation,               deletion, or change in value of any instance of               ifStackStatus.  If the interface stack has been               unchanged since the last re-initialization of the               local network management subsystem, then this object               contains a zero value."       ::= { ifMIBObjects 6 }   --   Generic Receive Address Table   --   -- This group of objects is mandatory for all types of   -- interfaces which can receive packets/frames addressed to   -- more than one address.   --   -- This table replaces the ifExtnsRcvAddr table.  The main   -- difference is that this table makes use of the RowStatus   -- textual convention, while ifExtnsRcvAddr did not.   ifRcvAddressTable  OBJECT-TYPE       SYNTAX      SEQUENCE OF IfRcvAddressEntry       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION               "This table contains an entry for each address               (broadcast, multicast, or uni-cast) for which the               system will receive packets/frames on a particular               interface, except as follows:               - for an interface operating in promiscuous mode,               entries are only required for those addresses for               which the system would receive frames were it not               operating in promiscuous mode.               - for 802.5 functional addresses, only one entry is               required, for the address which has the functional               address bit ANDed with the bit mask of all functional               addresses for which the interface will accept frames.               A system is normally able to use any unicast address               which corresponds to an entry in this table as a               source address."       ::= { ifMIBObjects 4 }McCloghrie & Kastenholz     Standards Track                    [Page 49]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997   ifRcvAddressEntry  OBJECT-TYPE       SYNTAX      IfRcvAddressEntry       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION               "A list of objects identifying an address for which               the system will accept packets/frames on the               particular interface identified by the index value               ifIndex."       INDEX  { ifIndex, ifRcvAddressAddress }       ::= { ifRcvAddressTable 1 }   IfRcvAddressEntry ::=       SEQUENCE {           ifRcvAddressAddress   PhysAddress,           ifRcvAddressStatus    RowStatus,           ifRcvAddressType      INTEGER       }   ifRcvAddressAddress OBJECT-TYPE       SYNTAX      PhysAddress       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION               "An address for which the system will accept               packets/frames on this entry's interface."       ::= { ifRcvAddressEntry 1 }   ifRcvAddressStatus OBJECT-TYPE       SYNTAX      RowStatus       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION               "This object is used to create and delete rows in the               ifRcvAddressTable."       ::= { ifRcvAddressEntry 2 }   ifRcvAddressType OBJECT-TYPE       SYNTAX      INTEGER {                       other(1),                       volatile(2),                       nonVolatile(3)                   }       MAX-ACCESS  read-create       STATUS      currentMcCloghrie & Kastenholz     Standards Track                    [Page 50]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997       DESCRIPTION               "This object has the value nonVolatile(3) for those               entries in the table which are valid and will not be               deleted by the next restart of the managed system.               Entries having the value volatile(2) are valid and               exist, but have not been saved, so that will not exist               after the next restart of the managed system.  Entries               having the value other(1) are valid and exist but are               not classified as to whether they will continue to               exist after the next restart."       DEFVAL  { volatile }       ::= { ifRcvAddressEntry 3 }   -- definition of interface-related traps.   linkDown NOTIFICATION-TYPE           OBJECTS { ifIndex, ifAdminStatus, ifOperStatus }           STATUS  current           DESCRIPTION               "A linkDown trap signifies that the SNMPv2 entity,               acting in an agent role, has detected that the               ifOperStatus object for one of its communication links               is about to enter the down state from some other state               (but not from the notPresent state).  This other state               is indicated by the included value of ifOperStatus."       ::= { snmpTraps 3 }   linkUp NOTIFICATION-TYPE           OBJECTS { ifIndex, ifAdminStatus, ifOperStatus }           STATUS  current           DESCRIPTION               "A linkDown trap signifies that the SNMPv2 entity,               acting in an agent role, has detected that the               ifOperStatus object for one of its communication links               left the down state and transitioned into some other               state (but not into the notPresent state).  This other               state is indicated by the included value of               ifOperStatus."       ::= { snmpTraps 4 }   -- conformance information   ifConformance OBJECT IDENTIFIER ::= { ifMIB 2 }   ifGroups      OBJECT IDENTIFIER ::= { ifConformance 1 }   ifCompliances OBJECT IDENTIFIER ::= { ifConformance 2 }McCloghrie & Kastenholz     Standards Track                    [Page 51]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997   -- compliance statements   ifCompliance2 MODULE-COMPLIANCE       STATUS  current       DESCRIPTION               "The compliance statement for SNMPv2 entities which               have network interfaces."       MODULE  -- this module           MANDATORY-GROUPS { ifGeneralInformationGroup, ifStackGroup2,                              ifCounterDiscontinuityGroup }           GROUP       ifFixedLengthGroup           DESCRIPTION               "This group is mandatory for all network interfaces               which are character-oriented or transmit data in               fixed-length transmission units."           GROUP       ifHCFixedLengthGroup           DESCRIPTION               "This group is mandatory only for those network               interfaces which are character-oriented or transmit               data in fixed-length transmission units, and for which               the value of the corresponding instance of ifSpeed is               greater than 20,000,000 bits/second."           GROUP       ifPacketGroup           DESCRIPTION               "This group is mandatory for all network interfaces               which are packet-oriented."           GROUP       ifHCPacketGroup           DESCRIPTION               "This group is mandatory only for those network               interfaces which are packet-oriented and for which the               value of the corresponding instance of ifSpeed is               greater than 650,000,000 bits/second."           GROUP       ifRcvAddressGroup           DESCRIPTION               "The applicability of this group MUST be defined by               the media-specific MIBs.  Media-specific MIBs must               define the exact meaning, use, and semantics of the               addresses in this group."McCloghrie & Kastenholz     Standards Track                    [Page 52]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997           OBJECT      ifLinkUpDownTrapEnable           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required."           OBJECT      ifPromiscuousMode           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required."           OBJECT      ifStackStatus           SYNTAX      INTEGER { active(1) } -- subset of RowStatus           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required, and only one of the six               enumerated values for the RowStatus textual convention               need be supported, specifically: active(1)."           OBJECT       ifAdminStatus           SYNTAX       INTEGER { up(1), down(2) }           MIN-ACCESS   read-only           DESCRIPTION               "Write access is not required, nor is support for the               value testing(3)."           OBJECT       ifAlias           MIN-ACCESS   read-only           DESCRIPTION               "Write access is not required."       ::= { ifCompliances 2 }   -- units of conformance   ifGeneralInformationGroup    OBJECT-GROUP       OBJECTS { ifIndex, ifDescr, ifType, ifSpeed, ifPhysAddress,                 ifAdminStatus, ifOperStatus, ifLastChange,                 ifLinkUpDownTrapEnable, ifConnectorPresent,                 ifHighSpeed, ifName, ifNumber, ifAlias,                 ifTableLastChange }       STATUS  current       DESCRIPTION               "A collection of objects providing information               applicable to all network interfaces."       ::= { ifGroups 10 }   -- the following five groups are mutually exclusive; at most   -- one of these groups is implemented for any interfaceMcCloghrie & Kastenholz     Standards Track                    [Page 53]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997   ifFixedLengthGroup    OBJECT-GROUP       OBJECTS { ifInOctets, ifOutOctets, ifInUnknownProtos,                 ifInErrors, ifOutErrors }       STATUS  current       DESCRIPTION               "A collection of objects providing information               specific to non-high speed (non-high speed interfaces               transmit and receive at speeds less than or equal to               20,000,000 bits/second) character-oriented or fixed-               length-transmission network interfaces."       ::= { ifGroups 2 }   ifHCFixedLengthGroup    OBJECT-GROUP       OBJECTS { ifHCInOctets, ifHCOutOctets,                 ifInOctets, ifOutOctets, ifInUnknownProtos,                 ifInErrors, ifOutErrors }       STATUS  current       DESCRIPTION               "A collection of objects providing information               specific to high speed (greater than 20,000,000               bits/second) character-oriented or fixed-length-               transmission network interfaces."       ::= { ifGroups 3 }   ifPacketGroup    OBJECT-GROUP       OBJECTS { ifInOctets, ifOutOctets, ifInUnknownProtos,                 ifInErrors, ifOutErrors,                 ifMtu, ifInUcastPkts, ifInMulticastPkts,                 ifInBroadcastPkts, ifInDiscards,                 ifOutUcastPkts, ifOutMulticastPkts,                 ifOutBroadcastPkts, ifOutDiscards,                 ifPromiscuousMode }       STATUS  current       DESCRIPTION               "A collection of objects providing information               specific to non-high speed (non-high speed interfaces               transmit and receive at speeds less than or equal to               20,000,000 bits/second) packet-oriented network               interfaces."       ::= { ifGroups 4 }   ifHCPacketGroup    OBJECT-GROUP       OBJECTS { ifHCInOctets, ifHCOutOctets,                 ifInOctets, ifOutOctets, ifInUnknownProtos,                 ifInErrors, ifOutErrors,                 ifMtu, ifInUcastPkts, ifInMulticastPkts,                 ifInBroadcastPkts, ifInDiscards,                 ifOutUcastPkts, ifOutMulticastPkts,McCloghrie & Kastenholz     Standards Track                    [Page 54]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997                 ifOutBroadcastPkts, ifOutDiscards,                 ifPromiscuousMode }       STATUS  current       DESCRIPTION               "A collection of objects providing information               specific to high speed (greater than 20,000,000               bits/second but less than or equal to 650,000,000               bits/second) packet-oriented network interfaces."       ::= { ifGroups 5 }   ifVHCPacketGroup    OBJECT-GROUP       OBJECTS { ifHCInUcastPkts, ifHCInMulticastPkts,                 ifHCInBroadcastPkts, ifHCOutUcastPkts,                 ifHCOutMulticastPkts, ifHCOutBroadcastPkts,                 ifHCInOctets, ifHCOutOctets,                 ifInOctets, ifOutOctets, ifInUnknownProtos,                 ifInErrors, ifOutErrors,                 ifMtu, ifInUcastPkts, ifInMulticastPkts,                 ifInBroadcastPkts, ifInDiscards,                 ifOutUcastPkts, ifOutMulticastPkts,                 ifOutBroadcastPkts, ifOutDiscards,                 ifPromiscuousMode }       STATUS  current       DESCRIPTION               "A collection of objects providing information               specific to higher speed (greater than 650,000,000               bits/second) packet-oriented network interfaces."       ::= { ifGroups 6 }   ifRcvAddressGroup    OBJECT-GROUP       OBJECTS { ifRcvAddressStatus, ifRcvAddressType }       STATUS  current       DESCRIPTION               "A collection of objects providing information on the               multiple addresses which an interface receives."       ::= { ifGroups 7 }   ifStackGroup2    OBJECT-GROUP       OBJECTS { ifStackStatus, ifStackLastChange }       STATUS  current       DESCRIPTION               "A collection of objects providing information on the               layering of MIB-II interfaces."       ::= { ifGroups 11 }   ifCounterDiscontinuityGroup  OBJECT-GROUP       OBJECTS { ifCounterDiscontinuityTime }       STATUS  currentMcCloghrie & Kastenholz     Standards Track                    [Page 55]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997       DESCRIPTION               "A collection of objects providing information               specific to interface counter discontinuities."       ::= { ifGroups 13 }   -- Deprecated Definitions - Objects   --   --    The Interface Test Table   --   -- This group of objects is optional.  However, a media-specific   -- MIB may make implementation of this group mandatory.   --   -- This table replaces the ifExtnsTestTable   --   ifTestTable   OBJECT-TYPE       SYNTAX      SEQUENCE OF IfTestEntry       MAX-ACCESS  not-accessible       STATUS      deprecated       DESCRIPTION               "This table contains one entry per interface.  It               defines objects which allow a network manager to               instruct an agent to test an interface for various               faults.  Tests for an interface are defined in the               media-specific MIB for that interface.  After invoking               a test, the object ifTestResult can be read to               determine the outcome.  If an agent can not perform               the test, ifTestResult is set to so indicate.  The               object ifTestCode can be used to provide further               test-specific or interface-specific (or even               enterprise-specific) information concerning the               outcome of the test.  Only one test can be in progress               on each interface at any one time.  If one test is in               progress when another test is invoked, the second test               is rejected.  Some agents may reject a test when a               prior test is active on another interface.               Before starting a test, a manager-station must first               obtain 'ownership' of the entry in the ifTestTable for               the interface to be tested.  This is accomplished with               the ifTestId and ifTestStatus objects as follows:            try_again:                get (ifTestId, ifTestStatus)                while (ifTestStatus != notInUse)                    /*McCloghrie & Kastenholz     Standards Track                    [Page 56]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997                     * Loop while a test is running or some other                     * manager is configuring a test.                     */                    short delay                    get (ifTestId, ifTestStatus)                }                /*                 * Is not being used right now -- let's compete                 * to see who gets it.                 */                lock_value = ifTestId                if ( set(ifTestId = lock_value, ifTestStatus = inUse,                         ifTestOwner = 'my-IP-address') == FAILURE)                    /*                     * Another manager got the ifTestEntry -- go                     * try again                     */                    goto try_again;                /*                 * I have the lock                 */                set up any test parameters.                /*                 * This starts the test                 */                set(ifTestType = test_to_run);                wait for test completion by polling ifTestResult                when test completes, agent sets ifTestResult                     agent also sets ifTestStatus = 'notInUse'                retrieve any additional test results, and ifTestId                if (ifTestId == lock_value+1) results are valid              A manager station first retrieves the value of the              appropriate ifTestId and ifTestStatus objects,              periodically repeating the retrieval if necessary,              until the value of ifTestStatus is 'notInUse'.  The              manager station then tries to set the same ifTestId              object to the value it just retrieved, the same              ifTestStatus object to 'inUse', and the corresponding              ifTestOwner object to a value indicating itself.  IfMcCloghrie & Kastenholz     Standards Track                    [Page 57]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997              the set operation succeeds then the manager has              obtained ownership of the ifTestEntry, and the value of              the ifTestId object is incremented by the agent (per              the semantics of TestAndIncr).  Failure of the set              operation indicates that some other manager has              obtained ownership of the ifTestEntry.              Once ownership is obtained, any test parameters can be              setup, and then the test is initiated by setting              ifTestType.  On completion of the test, the agent sets              ifTestStatus to 'notInUse'.  Once this occurs, the              manager can retrieve the results.  In the (rare) event              that the invocation of tests by two network managers              were to overlap, then there would be a possibility that              the first test's results might be overwritten by the              second test's results prior to the first results being              read.  This unlikely circumstance can be detected by a              network manager retrieving ifTestId at the same time as              retrieving the test results, and ensuring that the              results are for the desired request.              If ifTestType is not set within an abnormally long              period of time after ownership is obtained, the agent              should time-out the manager, and reset the value of the              ifTestStatus object back to 'notInUse'.  It is              suggested that this time-out period be 5 minutes.              In general, a management station must not retransmit a              request to invoke a test for which it does not receive              a response; instead, it properly inspects an agent's              MIB to determine if the invocation was successful.              Only if the invocation was unsuccessful, is the              invocation request retransmitted.              Some tests may require the interface to be taken off-              line in order to execute them, or may even require the              agent to reboot after completion of the test.  In these              circumstances, communication with the management              station invoking the test may be lost until after              completion of the test.  An agent is not required to              support such tests.  However, if such tests are              supported, then the agent should make every effort to              transmit a response to the request which invoked the              test prior to losing communication.  When the agent is              restored to normal service, the results of the test are              properly made available in the appropriate objects.              Note that this requires that the ifIndex value assigned              to an interface must be unchanged even if the testMcCloghrie & Kastenholz     Standards Track                    [Page 58]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997              causes a reboot.  An agent must reject any test for              which it cannot, perhaps due to resource constraints,              make available at least the minimum amount of              information after that test completes."       ::= { ifMIBObjects 3 }   ifTestEntry OBJECT-TYPE       SYNTAX       IfTestEntry       MAX-ACCESS   not-accessible       STATUS       deprecated       DESCRIPTION               "An entry containing objects for invoking tests on an               interface."       AUGMENTS  { ifEntry }       ::= { ifTestTable 1 }   IfTestEntry ::=       SEQUENCE {           ifTestId           TestAndIncr,           ifTestStatus       INTEGER,           ifTestType         AutonomousType,           ifTestResult       INTEGER,           ifTestCode         OBJECT IDENTIFIER,           ifTestOwner        OwnerString       }   ifTestId         OBJECT-TYPE       SYNTAX       TestAndIncr       MAX-ACCESS   read-write       STATUS       deprecated       DESCRIPTION               "This object identifies the current invocation of the               interface's test."       ::= { ifTestEntry 1 }   ifTestStatus     OBJECT-TYPE       SYNTAX       INTEGER { notInUse(1), inUse(2) }       MAX-ACCESS   read-write       STATUS       deprecated       DESCRIPTION               "This object indicates whether or not some manager               currently has the necessary 'ownership' required to               invoke a test on this interface.  A write to this               object is only successful when it changes its value               from 'notInUse(1)' to 'inUse(2)'.  After completion of               a test, the agent resets the value back to               'notInUse(1)'."       ::= { ifTestEntry 2 }McCloghrie & Kastenholz     Standards Track                    [Page 59]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997   ifTestType       OBJECT-TYPE       SYNTAX       AutonomousType       MAX-ACCESS   read-write       STATUS       deprecated       DESCRIPTION               "A control variable used to start and stop operator-               initiated interface tests.  Most OBJECT IDENTIFIER               values assigned to tests are defined elsewhere, in               association with specific types of interface.               However, this document assigns a value for a full-               duplex loopback test, and defines the special meanings               of the subject identifier:                   noTest  OBJECT IDENTIFIER ::= { 0 0 }               When the value noTest is written to this object, no               action is taken unless a test is in progress, in which               case the test is aborted.  Writing any other value to               this object is only valid when no test is currently in               progress, in which case the indicated test is               initiated.               When read, this object always returns the most recent               value that ifTestType was set to.  If it has not been               set since the last initialization of the network               management subsystem on the agent, a value of noTest               is returned."       ::= { ifTestEntry 3 }   ifTestResult  OBJECT-TYPE       SYNTAX       INTEGER {                        none(1),          -- no test yet requested                        success(2),                        inProgress(3),                        notSupported(4),                        unAbleToRun(5),   -- due to state of system                        aborted(6),                        failed(7)                    }       MAX-ACCESS   read-only       STATUS       deprecated       DESCRIPTION               "This object contains the result of the most recently               requested test, or the value none(1) if no tests have               been requested since the last reset.  Note that this               facility provides no provision for saving the results               of one test when starting another, as could be               required if used by multiple managers concurrently."McCloghrie & Kastenholz     Standards Track                    [Page 60]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997       ::= { ifTestEntry 4 }   ifTestCode  OBJECT-TYPE       SYNTAX       OBJECT IDENTIFIER       MAX-ACCESS   read-only       STATUS       deprecated       DESCRIPTION               "This object contains a code which contains more               specific information on the test result, for example               an error-code after a failed test.  Error codes and               other values this object may take are specific to the               type of interface and/or test.  The value may have the               semantics of either the AutonomousType or               InstancePointer textual conventions as defined inRFC1903.  The identifier:                   testCodeUnknown  OBJECT IDENTIFIER ::= { 0 0 }               is defined for use if no additional result code is               available."       ::= { ifTestEntry 5 }   ifTestOwner      OBJECT-TYPE       SYNTAX       OwnerString       MAX-ACCESS   read-write       STATUS       deprecated       DESCRIPTION               "The entity which currently has the 'ownership'               required to invoke a test on this interface."       ::= { ifTestEntry 6 }   -- Deprecated Definitions - Groups   ifGeneralGroup    OBJECT-GROUP       OBJECTS { ifDescr, ifType, ifSpeed, ifPhysAddress,                 ifAdminStatus, ifOperStatus, ifLastChange,                 ifLinkUpDownTrapEnable, ifConnectorPresent,                 ifHighSpeed, ifName }       STATUS  deprecated       DESCRIPTION               "A collection of objects deprecated in favour of               ifGeneralInformationGroup."       ::= { ifGroups 1 }   ifTestGroup    OBJECT-GROUP       OBJECTS { ifTestId, ifTestStatus, ifTestType,McCloghrie & Kastenholz     Standards Track                    [Page 61]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997                 ifTestResult, ifTestCode, ifTestOwner }       STATUS  deprecated       DESCRIPTION               "A collection of objects providing the ability to               invoke tests on an interface."       ::= { ifGroups 8 }   ifStackGroup    OBJECT-GROUP       OBJECTS { ifStackStatus }       STATUS  deprecated       DESCRIPTION               "The previous collection of objects providing               information on the layering of MIB-II interfaces."       ::= { ifGroups 9 }   ifOldObjectsGroup    OBJECT-GROUP       OBJECTS { ifInNUcastPkts, ifOutNUcastPkts,                 ifOutQLen, ifSpecific }       STATUS  deprecated       DESCRIPTION               "The collection of objects deprecated from the               original MIB-II interfaces group."       ::= { ifGroups 12 }   -- Deprecated Definitions - Compliance   ifCompliance MODULE-COMPLIANCE       STATUS  deprecated       DESCRIPTION               "The previous compliance statement for SNMPv2 entities               which have network interfaces."       MODULE  -- this module           MANDATORY-GROUPS { ifGeneralGroup, ifStackGroup }           GROUP       ifFixedLengthGroup           DESCRIPTION               "This group is mandatory for all network interfaces               which are character-oriented or transmit data in               fixed-length transmission units."           GROUP       ifHCFixedLengthGroup           DESCRIPTION               "This group is mandatory only for those network               interfaces which are character-oriented or transmitMcCloghrie & Kastenholz     Standards Track                    [Page 62]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997               data in fixed-length transmission units, and for which               the value of the corresponding instance of ifSpeed is               greater than 20,000,000 bits/second."           GROUP       ifPacketGroup           DESCRIPTION               "This group is mandatory for all network interfaces               which are packet-oriented."           GROUP       ifHCPacketGroup           DESCRIPTION               "This group is mandatory only for those network               interfaces which are packet-oriented and for which the               value of the corresponding instance of ifSpeed is               greater than 650,000,000 bits/second."           GROUP       ifTestGroup           DESCRIPTION               "This group is optional.  Media-specific MIBs which               require interface tests are strongly encouraged to use               this group for invoking tests and reporting results.               A medium specific MIB which has mandatory tests may               make implementation of this group mandatory."           GROUP       ifRcvAddressGroup           DESCRIPTION               "The applicability of this group MUST be defined by               the media-specific MIBs.  Media-specific MIBs must               define the exact meaning, use, and semantics of the               addresses in this group."           OBJECT      ifLinkUpDownTrapEnable           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required."           OBJECT      ifPromiscuousMode           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required."           OBJECT      ifStackStatus           SYNTAX      INTEGER { active(1) } -- subset of RowStatus           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required, and only one of the six               enumerated values for the RowStatus textual convention               need be supported, specifically: active(1)."McCloghrie & Kastenholz     Standards Track                    [Page 63]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997           OBJECT       ifAdminStatus           SYNTAX       INTEGER { up(1), down(2) }           MIN-ACCESS   read-only           DESCRIPTION               "Write access is not required, nor is support for the               value testing(3)."       ::= { ifCompliances 1 }   END7.  Acknowledgements   This memo has been produced by the IETF's Interfaces MIB working-   group.   The original proposal evolved from conversations and discussions with   many people, including at least the following: Fred Baker, Ted   Brunner, Chuck Davin, Jeremy Greene, Marshall Rose, Kaj Tesink, and   Dean Throop.8.  References   [1]  Case, J., McCloghrie, K., Rose, M., and        S. Waldbusser, "Structure of Management Information for        version 2 of the Simple Network Management Protocol        (SNMPv2)",RFC 1902, January 1996.   [2]  Case, J., McCloghrie, K., Rose, M., and        S. Waldbusser, "Textual Conventions for version 2 of the        Simple Network Management Protocol (SNMPv2)",RFC 1903,        January 1996.   [3]  Case, J., McCloghrie, K., Rose, M., and        S. Waldbusser, "Protocol Operations for version 2 of the        Simple Network Management Protocol (SNMPv2)",RFC 1905,        January 1996.   [4]  McCloghrie, K., and M. Rose, "Management Information Base for        Network Management of TCP/IP-based internets - MIB-II", STD        17,RFC 1213, March 1991.   [5]  Case, J., Fedor, M., Schoffstall, M., and J. Davin, "Simple        Network Management Protocol", STD 15,RFC 1157, May 1990.   [6]  Postel, J., "Internet Protocol", STD 5,RFC 791, September 1981.   [7]  McCloghrie, K., "Extensions to the Generic-Interface MIB",RFC1229, May 1991.McCloghrie & Kastenholz     Standards Track                    [Page 64]

RFC 2233            Interfaces Group MIB using SMIv2       November 1997   [8]  ATM Forum Technical Committee, "LAN Emulation Client        Management: Version 1.0 Specification", af-lane-0044.000, ATM        Forum, September 1995.   [9]  Stewart, B., "Definitions of Managed Objects for Character        Stream Devices using SMIv2",RFC 1658, July 1994.   [10] Bradner, S., "Key words for use in RFCs to Indicate        Requirements Levels",RFC 2119, March 1997.9.  Security Considerations   This MIB contains both readable objects whose values provide the   number and status of a device's network interfaces, and write-able   objects which allow an administrator to control the interfaces and to   perform tests on the interfaces.  Unauthorized access to the readable   objects is relatively innocuous.  Unauthorized access to the write-   able objects could cause a denial of service, or in combination with   other (e.g., physical) security breaches, could cause unauthorized   connectivity to a device.10.  Authors' Addresses   Keith McCloghrie   Cisco Systems, Inc.   170 West Tasman Drive   San Jose, CA  95134-1706   Phone: 408-526-5260   EMail: kzm@cisco.com   Frank Kastenholz   FTP Software   2 High Street   North Andover, Mass. USA 01845   Phone: 508-685-4000   EMail: kasten@ftp.comMcCloghrie & Kastenholz     Standards Track                    [Page 65]

RFC 2233            Interfaces Group MIB using SMIv2       November 199711.  Full Copyright Statement   Copyright (C) The Internet Society (1997).  All Rights Reserved.   This document and translations of it may be copied and furnished to   others, and derivative works that comment on or otherwise explain it   or assist in its implementation may be prepared, copied, published   and distributed, in whole or in part, without restriction of any   kind, provided that the above copyright notice and this paragraph are   included on all such copies and derivative works.  However, this   document itself may not be modified in any way, such as by removing   the copyright notice or references to the Internet Society or other   Internet organizations, except as needed for the purpose of   developing Internet standards in which case the procedures for   copyrights defined in the Internet Standards process must be   followed, or as required to translate it into languages other than   English.   The limited permissions granted above are perpetual and will not be   revoked by the Internet Society or its successors or assigns.   This document and the information contained herein is provided on an   "AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING   TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING   BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION   HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF   MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.McCloghrie & Kastenholz     Standards Track                    [Page 66]