Network Working Group                                         J. QuittekRequest for Comments: 3917                               NEC Europe Ltd.Category: Informational                                         T. Zseby                                                        Fraunhofer FOKUS                                                               B. Claise                                                           Cisco Systems                                                               S. Zander                                                    Swinburne University                                                            October 2004Requirements for IP Flow Information Export (IPFIX)Status of this Memo   This memo provides information for the Internet community.  It does   not specify an Internet standard of any kind.  Distribution of this   memo is unlimited.Copyright Notice   Copyright (C) The Internet Society (2004).Abstract   This memo defines requirements for the export of measured IP flow   information out of routers, traffic measurement probes, and   middleboxes.Table of Contents1.   Introduction. . . . . . . . . . . . . . . . . . . . . . . . .32.   Terminology . . . . . . . . . . . . . . . . . . . . . . . . .32.1.   IP Traffic Flow. . . . . . . . . . . . . . . . . . . .32.2.   Observation Point. . . . . . . . . . . . . . . . . . .42.3.   Metering Process . . . . . . . . . . . . . . . . . . .42.4.   Flow Record. . . . . . . . . . . . . . . . . . . . . .52.5.   Exporting Process. . . . . . . . . . . . . . . . . . .52.6.   Collecting Process . . . . . . . . . . . . . . . . . .53.   Applications Requiring IP Flow Information Export . . . . . .63.1.   Usage-based Accounting . . . . . . . . . . . . . . . .63.2.   Traffic Profiling. . . . . . . . . . . . . . . . . . .73.3.   Traffic Engineering. . . . . . . . . . . . . . . . . .73.4.   Attack/Intrusion Detection . . . . . . . . . . . . . .73.5.   QoS Monitoring . . . . . . . . . . . . . . . . . . . .84.   Distinguishing Flows. . . . . . . . . . . . . . . . . . . . .84.1.   Encryption . . . . . . . . . . . . . . . . . . . . . .94.2.   Interfaces . . . . . . . . . . . . . . . . . . . . . .9Quittek, et al.              Informational                      [Page 1]

RFC 3917                   IPFIX Requirements               October 20044.3.   IP Header Fields . . . . . . . . . . . . . . . . . . .94.4.   Transport Header Fields. . . . . . . . . . . . . . . .104.5.   MPLS Label . . . . . . . . . . . . . . . . . . . . . .104.6.   DiffServ Code Point. . . . . . . . . . . . . . . . . .105.   Metering Process. . . . . . . . . . . . . . . . . . . . . . .105.1.   Reliability. . . . . . . . . . . . . . . . . . . . . .105.2.   Sampling . . . . . . . . . . . . . . . . . . . . . . .115.3.   Overload Behavior. . . . . . . . . . . . . . . . . . .115.4.   Timestamps . . . . . . . . . . . . . . . . . . . . . .125.5.   Time Synchronization . . . . . . . . . . . . . . . . .125.6.   Flow Expiration. . . . . . . . . . . . . . . . . . . .135.7.   Multicast Flows. . . . . . . . . . . . . . . . . . . .135.8.   Packet Fragmentation . . . . . . . . . . . . . . . . .135.9.   Ignore Port Copy . . . . . . . . . . . . . . . . . . .136.   Data Export . . . . . . . . . . . . . . . . . . . . . . . . .146.1.   Information Model. . . . . . . . . . . . . . . . . . .146.2.   Data Model . . . . . . . . . . . . . . . . . . . . . .166.3.   Data Transfer. . . . . . . . . . . . . . . . . . . . .166.3.1. Congestion Awareness. . . . . . . . . . . . . .166.3.2. Reliability . . . . . . . . . . . . . . . . . .176.3.3. Security. . . . . . . . . . . . . . . . . . . .186.4.   Push and Pull Mode Reporting . . . . . . . . . . . . .186.5.   Regular Reporting Interval . . . . . . . . . . . . . .186.6.   Notification on Specific Events. . . . . . . . . . . .186.7.   Anonymization. . . . . . . . . . . . . . . . . . . . .187.   Configuration . . . . . . . . . . . . . . . . . . . . . . . .197.1.   Configuration of the Metering Process. . . . . . . . .197.2.   Configuration of the Exporting Process . . . . . . . .198.   General Requirements. . . . . . . . . . . . . . . . . . . . .208.1.   Openness . . . . . . . . . . . . . . . . . . . . . . .208.2.   Scalability. . . . . . . . . . . . . . . . . . . . . .208.3.   Several Collecting Processes . . . . . . . . . . . . .209.   Special Device Considerations . . . . . . . . . . . . . . . .2010.  Security Considerations . . . . . . . . . . . . . . . . . . .2310.1.  Disclosure of Flow Information Data. . . . . . . . . .2310.2.  Forgery of Flow Records. . . . . . . . . . . . . . . .2410.3.  Denial of Service (DoS) Attacks. . . . . . . . . . . .2411.  Acknowledgments . . . . . . . . . . . . . . . . . . . . . . .2512.  Appendix: Derivation of Requirements from Applications. . . .2613.  References  . . . . . . . . . . . . . . . . . . . . . . . . .3113.1.  Normative References . . . . . . . . . . . . . . . . .3113.2.  Informative References . . . . . . . . . . . . . . . .3114. Authors' Addresses . . . . . . . . . . . . . . . . . . . . . .3215. Full Copyright Statement . . . . . . . . . . . . . . . . . . .33Quittek, et al.              Informational                      [Page 2]

RFC 3917                   IPFIX Requirements               October 20041.  Introduction   There are several applications that require flow-based IP traffic   measurements.  Such measurements could be performed by a router while   forwarding the traffic, by a middlebox [RFC3234], or by a traffic   measurement probe attached to a line or a monitored port.  This memo   defines requirements for exporting traffic flow information out of   these boxes for further processing by applications located on other   devices.  They serve as input to the standardization of the IPFIX   protocol specifications.   Insection 3, a selection of such applications is presented.  The   following sections list requirements derived from these applications.   In its early discussions the IPFIX Working Group chose to evaluate   existing flow export protocols at the same time it was developing   this 'requirements' document.   Flow export, however, is not performed by a protocol acting alone, it   also requires a system of co-operating processes.  In producing IPFIX   requirements, therefore, the Working Group decided to specify what   was required by these various processes - the metering process, the   exporting process, etc.  In these specifications we use lower-case   for the words must, may, and should, to indicate that IPFIX   implementors have some freedom as to how to meet the requirements.   The Working Group's goal is to produce standards-track RFCs   describing the IPFIX information model and export protocol RFCs.  As   well as meeting the requirements set out in this document, the   information model and protocol documents will provide a full   specification of the IPFIX system, and will use uppercase keywords as   in [RFC 2119].2.  Terminology   The following terminology is used in this document:2.1.  IP Traffic Flow   There are several definitions of the term 'flow' being used by the   Internet community.  Within this document we use the following one:   A flow is defined as a set of IP packets passing an observation point   in the network during a certain time interval.  All packets belonging   to a particular flow have a set of common properties.  Each property   is defined as the result of applying a function to the values of:Quittek, et al.              Informational                      [Page 3]

RFC 3917                   IPFIX Requirements               October 2004      1. one or more packet header field (e.g., destination IP address),         transport header field (e.g., destination port number), or         application header field (e.g., RTP header fields [RFC3550])      2. one or more characteristics of the packet itself (e.g., number         of MPLS labels, etc.)      3. one or more of fields derived from packet treatment (e.g., next         hop IP address, the output interface, etc.)   A packet is defined to belong to a flow if it completely satisfies   all the defined properties of the flow.   This definition covers the range from a flow containing all packets   observed at a network interface to a flow consisting of just a single   packet between two applications with a specific sequence number.   Please note that the flow definition does not necessarily match a   general application-level end-to-end stream.  However, an application   may derive properties of application-level streams by processing   measured flow data.  Also, please note that although packet   properties may depend on application headers, there is no requirement   defined in this document related to application headers.2.2.  Observation Point   The observation point is a location in the network where IP packets   can be observed.  Examples are a line to which a probe is attached, a   shared medium such as an Ethernet-based LAN, a single port of a   router, or a set of interfaces (physical or logical) of a router.   Note that one observation point may be a superset of several other   observation points.  For example one observation point can be an   entire line card.  This would be the superset of the individual   observation points at the line card's interfaces.2.3.  Metering Process   The metering process generates flow records.  Input to the process   are packet headers observed at an observation point and packet   treatment at the observation point, for example the selected output   interface.  The metering process consists of a set of functions that   includes packet header capturing, timestamping, sampling,   classifying, and maintaining flow records.   The maintenance of flow records may include creating new records,   updating existing ones, computing flow statistics, deriving further   flow properties, detecting flow expiration, passing flow records to   the exporting process, and deleting flow records.Quittek, et al.              Informational                      [Page 4]

RFC 3917                   IPFIX Requirements               October 2004   The sampling function and the classifying function may be applied   more than once with different parameters.  Figure 1 shows the   sequence in which the functions are applied.  Sampling is not   illustrated in the figure; it may be applied before any other   function.                           packet header capturing                                     |                                timestamping                                     |                                     v                              +----->+                              |      |                              | classifying                              |      |                              +------+                                     |                          maintaining flow records                                     |                                     v                 Figure 1: Functions of the metering process2.4.  Flow Record   A flow record contains information about a specific flow that was   metered at an observation point.  A flow record contains measured   properties of the flow (e.g., the total number of bytes of all   packets of the flow) and usually characteristic properties of the   flow (e.g., source IP address).2.5.  Exporting Process   The exporting process sends flow records to one or more collecting   processes.  The flow records are generated by one or more metering   processes.2.6.  Collecting Process   The collecting process receives flow records from one or more   exporting processes.  The collecting process might store received   flow records or further process them, but these actions are out of   the scope of this document.Quittek, et al.              Informational                      [Page 5]

RFC 3917                   IPFIX Requirements               October 20043.  Applications Requiring IP Flow Information Export   This section describes a selection of applications requiring IP flow   information export.  Because requirements for flow export listed in   further sections below are derived from these applications, their   selection is crucial.  The goal of this requirements document is not   to cover all possible applications with all their flow export   requirements, but to cover applications which are considered to be of   significant importance in today's and/or future IP networks, and for   which requirements can be met with reasonable technical effort.   The list of applications should lead to a better understanding of the   requirements which is particularly important when designing or   implementing traffic flow metering functions.  A detailed overview of   which requirement was derived from which application(s) is given in   the appendix.   Please note that the described applications can have a large number   of differing implementations.  Requirement details or requirement   significance (required (must), recommended (should), optional (may))   could differ for specific implementations and/or for specific   application scenarios.  Therefore we derive the requirements from the   general functionality of the selected applications.  Some particular   cases will even mandate more stringent requirements than the ones   defined in this document.  For example, usage-based accounting is   certainly the application that will probably mandate the highest   degree of reliability amongst the applications discussed below.  The   reliability requirements defined in sections5.1 and6.3.2. are not   sufficient to guarantee the level of reliability that is needed for   many usage-based accounting systems.  Particular reliability   requirements for accounting systems are discussed in [RFC2975].3.1.  Usage-based Accounting   Several new business models for selling IP services and IP-based   services are currently under investigation.  Beyond flat rate   services which do not need accounting, accounting can be based on   time or volume.  Accounting data can serve as input for billing   systems.  Accounting can be performed per user or per user group, it   can be performed just for basic IP service or individually per high-   level service and/or per content type delivered.  For advanced/future   services, accounting may also be performed per class of service, per   application, per time of day, per (label switched) path used, etc.Quittek, et al.              Informational                      [Page 6]

RFC 3917                   IPFIX Requirements               October 20043.2.  Traffic Profiling   Traffic profiling is the process of characterizing IP flows by using   a model that represents key parameters of the flows such as flow   duration, volume, time, and burstiness.  It is a prerequisite for   network planning, network dimensioning, trend analysis, business   model development, and other activities.  It depends heavily on the   particular traffic profiling objective(s), which statistics, and   which accuracy are required from the measurements.  Typical   information needed for traffic profiling is the distribution of used   services and protocols in the network, the amount of packets of a   specific type (e.g., percentage of IPv6 packets) and specific flow   profiles.   Since objectives for traffic profiling can vary, this application   requires a high flexibility of the measurement infrastructure,   especially regarding the options for measurement configuration and   packet classification.3.3.  Traffic Engineering   Traffic Engineering (TE) comprises methods for measurement,   modelling, characterization and control of a network.  The goal of TE   is the optimization of network resource utilization and traffic   performance [RFC2702].  Since control and administrative reaction to   measurement results requires access to the involved network nodes, TE   mechanisms and the required measurement function usually are   performed within one administrative domain.  Typical parameters   required for TE are link utilization, load between specific network   nodes, number, size and entry/exit points of the active flows and   routing information.3.4.  Attack/Intrusion Detection   Capturing flow information plays an important role for network   security, both for detection of security violation, and for   subsequent defense.  In case of a Denial of Service (DOS) attack,   flow monitoring can allow detection of unusual situations or   suspicious flows.  In a second step, flow analysis can be performed   in order to gather information about the attacking flows, and for   deriving a defense strategy.   Intrusion detection is a potentially more demanding application which   would not only look at specific characteristics of flows, but may   also use a stateful packet flow analysis for detecting specific,   suspicious activities, or unusually frequent activities.  Such   activities may be characterized by specific communication patterns,   detectable by characteristic sequences of certain packet types.Quittek, et al.              Informational                      [Page 7]

RFC 3917                   IPFIX Requirements               October 20043.5.  QoS Monitoring   QoS monitoring is the passive measurement of quality parameters for   IP flows.  In contrast to active measurements, passive measurements   utilize the existing traffic in the network for QoS analysis.  Since   no test traffic is sent, passive measurements can only be applied in   situations where the traffic of interest is already present in the   network.  One example application is the validation of QoS parameters   negotiated in a service level specification.  Note that   passive/active measurement is also referred to as non-   intrusive/intrusive measurement or as measurement of   observed/synthetic traffic.   Passive measurements cannot provide the kind of controllable   experiments that can be achieved with active measurements.  On the   other hand passive measurements do not suffer from undesired side   effects caused by sending test traffic (e.g., additional load,   potential differences in treatment of test traffic and real customer   traffic).   QoS monitoring often requires the correlation of data from multiple   observation points (e.g., for measuring one-way metrics).  This   requires proper clock synchronization of the involved metering   processes.  For some measurements, flow records and/or notifications   on specific events at the different observation points must be   correlated, for example the arrival of a certain packet.  For this,   the provisioning of post-processing functions (e.g., the generation   of packet IDs) at the metering processes would be useful.  Since QoS   monitoring can lead to a huge amount of measurement result data, it   would highly benefit from mechanisms to reduce the measurement data,   like aggregation of results and sampling.   Please note that not all requirements for QoS monitoring are covered   by the IPFIX requirements specified in the following sections.  The   IPFIX requirements are targeted at per flow information including   summaries of per-packet properties for packets within a flow, but not   per-packet information itself.  For example jitter measurement   requires timestamping each packet and reporting of all timestamps of   a flow, but the IPFIX requirements only cover timestamps of first and   last packet of a flow.4.  Distinguishing Flows   Packets are mapped to flows by evaluating their properties.  Packets   with common properties are considered to belong to the same flow.  A   packet showing at least one difference in the set of properties is   considered to belong to a different flow.Quittek, et al.              Informational                      [Page 8]

RFC 3917                   IPFIX Requirements               October 2004   The following subsections list a set of properties which a metering   process must, should, or may be able to evaluate for mapping packets   to flows.  Please note that requiring the ability to evaluate a   certain property does not imply that this property must be evaluated   for each packet.  In other words, meeting the IPFIX requirements   means that the metering process in general must be able, via its   configuration, to somehow support to distinguish flows via all the   must fields, even if in certain circumstances/for certain   applications, only a subset of the must fields is needed and   effectively used to distinguish flows.   Which combination of properties is used for distinguishing flows and   how these properties are evaluated depends on the configuration of   the metering process.  The configured choice of evaluated properties   strongly depends on the environment and purpose of the measurement   and on the information required by the collecting process.  But in   any case, a collecting process must be able to clearly identify, for   each received flow record, which set of properties was used for   distinguishing this flow from other ones.   For specific deployments, only a subset of the required properties   listed below can be used to distinguish flows. For example, in order   to aggregate the flow records and reduce the number of flow records   exported.  On the other hand, some other deployments will require   distinguishing flows by some extra parameters, such as the TTL field   of the IP header or the BGP Autonomous System number [RFC1771] of the   IP destination address.4.1.  Encryption   If encryption is used, the metering process might not be able to   access all header fields.  A metering process must meet the   requirements stated in thissection 4 only for packets that have the   relevant header fields not encrypted.4.2.  Interfaces   The metering process must be able to separate flows by the incoming   interface or by the outgoing interface or by both of them.4.3.  IP Header Fields   The metering process must be able to separate flows by the following   fields of the IP header:      1. source IP address      2. destination IP addressQuittek, et al.              Informational                      [Page 9]

RFC 3917                   IPFIX Requirements               October 2004      3. protocol type (TCP, UDP, ICMP, ...)   For source address and destination address, separating by full match   must be supported as well as separation by prefix match.   The metering process should be able to separate flows by the IP   version number if the observation point is located at a device that   is supporting more than one IP version.4.4.  Transport Header Fields   The metering process must be able to separate flows by the port   numbers of the transport header in case of TCP or UDP being used as   transport protocol.  The metering process should be able to separate   flows by the port numbers of the transport header in case of SCTP   [RFC2960].   For separation, both, source and destination port number must be   supported for distinguishing flows, individually as well as in   combination.4.5.  MPLS Label   If the observation point is located at a device supporting   Multiprotocol Label Switching (MPLS, see [RFC3031]) then the metering   process must be able to separate flows by the MPLS label.4.6.  DiffServ Code Point   If the observation point is located at a device supporting   Differentiated Services (DiffServ) then the metering process must be   able to separate flows by the DiffServ Code Point (DSCP, see   [RFC2474]).5.  Metering Process   The following are requirements for the metering process.  All   measurements must be conducted from the point of view of the   observation point.5.1.  Reliability   The metering process must either be reliable or the absence of   reliability must be known and indicated.  The metering process is   reliable if each packet passing the observation point is metered   according to the configuration of the metering process.  If, e.g.,Quittek, et al.              Informational                     [Page 10]

RFC 3917                   IPFIX Requirements               October 2004   due to some overload, not all passing packets can be included into   the metering process, then the metering process must be able to   detect this failure and to report it.5.2.  Sampling   Sampling describes the systematic or random selection of a subset of   elements (the sample) out of a set of elements (the parent   population).  Usually the purpose of applying sampling techniques is   to estimate a parameter of the parent population by using only the   elements of the subset.  Sampling techniques can be applied for   instance to select a subset of packets out of all packets of a flow   or to select a subset of flows out of all flows on a link.  Sampling   methods differ in their sampling strategy (e.g., systematic or   random) and in the event that triggers the selection of an element.   The selection of one packet can for instance be triggered by its   arrival time (time-based sampling), by its position in the flow   (count-based sampling) or by the packet content (content-based   sampling).   The metering process may support packet sampling.  If sampling is   supported, the sampling configuration must be well defined.  The   sampling configuration includes the sampling method and all its   parameters.   If the sampling configuration is changed during operation, the new   sampling configuration with its parameters must be indicated to all   collecting processes receiving the affected flow records.  Changing   the sampling configuration includes: adding a sampling function to   the metering process, removing a sampling function from the metering   process, change sampling method, and change sampling parameter(s).   In case of any change in the sampling configuration, all flow records   metered by the previous sampling configuration must be terminated and   exported according to the export configuration.  The metering process   must not merge the flow records generated with the new sampling   configuration with the flow records generated with the previous   sampling configuration.5.3.  Overload Behavior   In case of an overload, for example lack of memory or processing   power, the metering process may change its behavior in order to cope   with the lack of resources.  Possible reactions include:Quittek, et al.              Informational                     [Page 11]

RFC 3917                   IPFIX Requirements               October 2004         -  Reduce the number of flows to be metered.  This can be            achieved by more coarse-grained flow measurement or by a            restriction of the flow records to a subset of the set of            original ones.         -  Start sampling packets before they are processed by the            metering process or - if sampling is already performed -            reduce the sampling frequency.         -  Stop metering.         -  Reducing the resource usage of competing processes on the            same device.  Example: reducing the packet forwarding            throughput   Overload behavior is not restricted to the four options listed above.   But in case the overload behavior induces a change of the metering   process behavior, the overload behavior must be clearly defined.   For some flows, the change of behavior might have an impact on the   data that would be stored in the associated flow records after the   change, for example if the packet classification is changed or the   sampling frequency.  These flows must be considered as terminated and   the associated flow records must be exported separately from new ones   generated after the behavior change.  The terminated flow records and   new ones generated after the behavior change must not be merged by   the metering process.  The collecting process must be able to   distinguish the affected flow records generated before and after the   change of behavior.  This requirement does not apply to flows and   associated flow records not affected by the change of metering   process behavior.5.4.  Timestamps   The metering process must be able to generate timestamps for the   first and the last observation of a packet of a flow at the   observation point.  The timestamp resolution must be at least the one   of the sysUpTime [RFC3418], which is one centisecond.5.5.  Time Synchronization   It must be possible to synchronize timestamps generated by a metering   process with Coordinated Universal Time (UTC).   Note that the possibility of synchronizing timestamps of each single   metering process with UTC implies the possibility of synchronizing   timestamps generated by different metering processes.Quittek, et al.              Informational                     [Page 12]

RFC 3917                   IPFIX Requirements               October 2004   Note that this does not necessarily imply that timestamps generated   by the metering process are UTC timestamps.  For example, this   requirement can be met by using local system clock values as   timestamps and adding an additional timestamp when exporting a report   to a collecting process.  Then the collecting process can synchronize   the timestamps by calculating the offset between UTC and the system   clock of the metering process.5.6.  Flow Expiration   The metering process must be able to detect flow expirations.  A flow   is considered to be expired if no packet of this flow has been   observed for a given timeout interval.  The metering process may   support means for detecting the expiration of a flow before a timeout   occurs, for example by detecting the FIN or RST bits in a TCP   connection.  The procedure for detecting a flow expiration must be   clearly defined.5.7.  Multicast Flows   For multicast flows containing packets replicated to multiple output   interfaces, the metering process should be able to maintain discrete   flow records per different output interface.  For example, the   metering process should be able to report an incoming multicast   packet that is replicated to four output interfaces in four different   flow records that differ by the output interface.5.8.  Packet Fragmentation   In case of IP packet fragmentation and depending on the   classification scheme, only the zero-offset fragment of a single   initial packet might contain sufficient information to classify the   packet.  Note that this fragment should be the first one generated by   the router imposing the fragmentation [RFC791], but might not be the   first one observed by the IPFIX device, due to reordering reasons.   The metering process may keep state of IP packet fragmentation in   order to map fragments that do not contain sufficient header   information correctly to flows.5.9.  Ignore Port Copy   The metering process may be able to ignore packets which are   generated by a port copy function acting at the device where the   observation point of a flow is located.Quittek, et al.              Informational                     [Page 13]

RFC 3917                   IPFIX Requirements               October 20046.  Data Export   The following are requirements for exporting flow records out of the   exporting process.  Beside requirements on the data transfer, we   separate requirements concerning the information model from   requirements concerning the data model.  Furthermore, we list   requirements on reporting times and notification on specific events,   and on anonymization of flow records.6.1.  Information Model   The information model for the flow information export is the list of   attributes of a flow to be contained in the report (including the   semantics of the attributes).   This section lists attributes an exporting process must, should or   may be able to report.  This does not imply that each exported flow   record must contain all required attributes.  But it implies that it   must be possible to configure the exporting process in a way that the   information of all required attributes can be transmitted from the   exporting process to the receiving collecting process(es) for each   exported flow.   In other words, meeting the IPFIX requirements means that the   exporting process in general must be able, via its configuration, to   somehow support to report all the must fields, even if in certain   circumstances or for certain applications, only a subset of the set   of all must fields is needed and effectively reported.   Beyond that, the exporting process might offer to report further   attributes not mentioned here.  A particular flow record may contain   some of the "required" attributes as well as some additional ones,   for example covering future technologies.   This document does not impose that the following attributes are   reported for every single flow record, especially for repetitive   attributes.  For example, if the observation point is the incoming   packet stream at the IP interface with the ifIndex value 3, then this   observation point does not have to be exported as part of every   single flow record.  Exporting it just once might give sufficient   information to the collecting process.   The exporting process must be able to report the following attributes   for each metered flow:      1.  IP version number          This requirement only applies if the observation point is          located at a device supporting more than one version of IP.Quittek, et al.              Informational                     [Page 14]

RFC 3917                   IPFIX Requirements               October 2004      2.  source IP address      3.  destination IP address      4.  IP protocol type (TCP,UDP,ICMP,...)      5.  if protocol type is TCP or UDP: source TCP/UDP port number      6.  if protocol type is TCP or UDP: destination TCP/UDP port          number      7.  packet counter          If a packet is fragmented, each fragment is counted as an          individual packet.      8.  byte counter          The sum of the total length in bytes of all IP packets          belonging to the flow.  The total length of a packet covers IP          header and IP payload.      9.  type of service octet (in case of IPv4), traffic class octet          (in case of IPv6).  According to [RFC2474], these octets          include the DiffServ Code Point that has a length of 6 bits.      10. in case of IPv6: Flow Label      11. if MPLS is supported at the observation point: the top MPLS          label or the corresponding forwarding equivalence class (FEC,          [RFC3031]) bound to that label.  The FEC is typically defined          by an IP prefix.      12. timestamp of the first packet of the flow      13. timestamp of the last packet of the flow      14. if sampling is used: sampling configuration      15. unique identifier of the observation point      16. unique identifier of the exporting process   The exporting process should be able to report the following   attributes for each metered flow:      17. if protocol type is ICMP: ICMP type and code      18. input interface (ifIndex)          This requirement does not apply if the observation point is          located at a probe device.      19. output interface (ifIndex)          This requirement does not apply if the observation point is          located at a probe device.      20. multicast replication factor          the number of outgoing packets originating from a single          incoming multicast packet.  This is a dynamic property of          multicast flows, that may change over time.  For unicast flows          it has the constant value 1.  The reported value must be the          value of the factor at the time the flow record is exported.   The exporting process may be able to report the following attributes   for each metered flow:      21. Time To Live (in case of IPv4) or Hop Limit (in case of IPv6)Quittek, et al.              Informational                     [Page 15]

RFC 3917                   IPFIX Requirements               October 2004      22. IP header flags      23. TCP header flags      24. dropped packet counter at the observation point          If a packet is fragmented, each fragment must be counted as an          individual packet.      25. fragmented packet counter          counter of all packets for which the fragmented bit is set in          the IP header      26. next hop IP address      27. source BGP Autonomous System number (see [RFC1771])      28. destination BGP Autonomous System number      29. next hop BGP Autonomous System number6.2.  Data Model   The data model describes how information is represented in flow   records.   The data model must be extensible for future attributes to be added.   Even if a set of attributes is fixed in the flow record, the data   model must provide a way of extending the record by configuration or   for certain implementations.   The data model used for exporting flow information must be flexible   concerning the flow attributes contained in flow records.  A flexible   record format would offer the possibility of defining records in a   flexible (customizable) way regarding the number and type of   contained attributes.   The data model should be independent of the underlying transport   protocol, i.e., the data transfer.6.3.  Data Transfer   Requirements for the data transfer include reliability, congestion   awareness, and security requirements.  For meeting these requirements   the exporting process can utilize existing security features provided   by the device hosting the process and/or provided by the transport   network.  For example it can use existing security technologies for   authentication and encryption or it can rely on physical protection   of a separated network for transferring flow information.6.3.1.  Congestion Awareness   For the data transfer, a congestion aware protocol must be supported.Quittek, et al.              Informational                     [Page 16]

RFC 3917                   IPFIX Requirements               October 20046.3.2.  Reliability   Loss of flow records during the data transfer from the exporting   process to the collecting process must be indicated at the collecting   process.  This indication must allow the collecting process to gauge   the number of flow records lost.  Possible reasons for flow records   loss include but are not limited to:      1. Metering process limitations: lack of memory, processing power,         etc.  These limitations are already covered insection 5.1.      2. Exporting process limitations: lack of memory, processing         power, etc.      3. Data transfer problems: packets that carry flow records sent         from the exporting process to the collecting process, are         dropped by the network.  Examples are connection failures and         losses by a transport protocol that specifically offers         congestion avoidance without persistent transport-level         reliability.      4. Collecting process limitations: it may be experiencing         congestion and not able to buffer new flows records.      5. Operation and Maintenance: the collecting process is taken down         for maintenance or other administrative purposes.   Please note that if an unreliable transport protocol is used,   reliability can be provided by higher layers.  If reliability is   provided by higher layers, only lack of overall reliability must be   indicated.  For example reordering could be dealt with by adding a   sequence number to each packet.   The data transfer between exporting process and collecting process   must be open to reliability extensions including at least      - retransmission of lost flow records,      - detection of disconnection and fail-over, and      - acknowledgement of flow records by the collecting process.   This extensibility may be used to provide additional reliability.   The extended protocol must still meet the requirements described in   this section, particularly, it must still be congestion aware.   Therefore, extensions using retransmissions must use exponential   backoff.Quittek, et al.              Informational                     [Page 17]

RFC 3917                   IPFIX Requirements               October 20046.3.3.  Security   Confidentiality of IPFIX data transferred from an exporting process   to a collecting process must be ensured.   Integrity of IPFIX data transferred from an exporting process to a   collecting process must be ensured.   Authenticity of IPFIX data transferred from an exporting process to a   collecting process must be ensured.   The security requirements have been derived from an analysis of   potential security threads.  The analysis is summarized inSection10.6.4.  Push and Pull Mode Reporting   In general, there are two ways of deciding on reporting times: push   mode and pull mode.  In push mode, the exporting process decides   without an external trigger when to send flow records.  In pull mode,   sending flow records is triggered by an explicit request from a   collecting process.  The exporting process must support push mode   reporting, it may support pull mode reporting.6.5.  Regular Reporting Interval   The exporting process should be capable of reporting measured traffic   data regularly according to a given interval length.6.6.  Notification on Specific Events   The exporting process may be capable of sending notifications to a   collecting process, if a specific event occurs.  Such an event can   be, for instance, the arrival of the first packet of a new flow, or   the termination of a flow after flow timeout.6.7.  Anonymization   The exporting process may be capable of anonymizing source and   destination IP addresses in flow data before exporting them.  It may   support anonymization of port numbers and other fields.  Please note   that anonymization is not originally an application requirement, but   derived from general requirements for treatment of measured traffic   data within a network.   For several applications anonymization cannot be applied, for example   for accounting and traffic engineering.  However, for protecting the   network user's privacy, anonymization should be applied wheneverQuittek, et al.              Informational                     [Page 18]

RFC 3917                   IPFIX Requirements               October 2004   possible.  In many cases it is sufficient if anonymization is   performed at the collecting process after flow information has been   exported.  This provides a reasonable protection of privacy as long   as confidentiality of the export is provided.   It would be desirable to request that all IPFIX exporters provide   anonymization of flow records, but algorithms for anonymization are   still a research issue.  Several are known but the security they   provide and their other properties are not yet studied sufficiently.   Also, there is no standardized method for anonymization.  Therefore,   the requirement for the exporting process supporting anonymization is   qualified with 'may' and not with 'must'.   If anonymized flow data is exported, this must be clearly indicated   to all receiving collecting processes, such that they can distinguish   anonymized data from non-anonymized data.7.  Configuration   If configuration is done remotely, security should be provided for   the configuration process covering confidentiality, integrity, and   authenticity.  The means used for remote configuration are out of the   scope of this document.7.1.  Configuration of the Metering Process   The metering process must provide a way of configuring traffic   measurement.  The following parameters of the metering process should   be configurable:         1. specification of the observation point            e.g., an interface or a list of interfaces to be monitored.         2. specifications of flows to be metered         3. flow timeouts   The following parameters may be configurable:         4. sampling method and parameters, if feature is supported         5. overload behavior, if feature is supported7.2.  Configuration of the Exporting Process   The exporting process must provide a way of configuring the data   export.  The following parameters of the exporting process should be   configurable:         1. reporting data format            Specifying the reporting data format must include aQuittek, et al.              Informational                     [Page 19]

RFC 3917                   IPFIX Requirements               October 2004            selection of attributes to be reported for each flow.         2. the collecting process(es) to which flows are reported         3. the reporting interval            This requirement only applies if the exporting process            supports reporting in regular intervals.         4. notifications to be sent to the collecting process(es)            This requirement only applies if the exporting process            supports notifications.         5. flow anonymization            This requirement only applies if the exporting process            supports flow anonymization.8.  General Requirements8.1.  Openness   IPFIX specifications should be open to future technologies.  This   includes extensibility of configuration of the metering process and   the exporting process.   Openness is also required concerning the extensibility of the data   model, as stated insection 6.2.8.2.  Scalability   Data collection from hundreds of different exporting processes must   be supported.  The collecting process must be able to distinguish   several hundred exporting processes by their identifiers.8.3.  Several Collecting Processes   The exporting process may be able to export flow information to more   than one collecting process.  If an exporting process is able to   export flow records to multiple collecting processes then it must be   able to ensure that the flow records can be identified so that   duplicates can be detected between different collecting processes and   double counting problems can be avoided.9.  Special Device Considerations   This document intends to avoid constraining the architecture of   probes, routers, and other devices hosting observation points,   metering processes, exporting processes, and/or collecting processes.   It can be expected that typically observation point, metering   process, and exporting process are co-located at a single device.   However, the requirements defined in this document do not exclude   devices that derive from this configuration.  Figure 2 shows some   examples.Quittek, et al.              Informational                     [Page 20]

RFC 3917                   IPFIX Requirements               October 2004   All examples are composed of one or more of the following elements:   observation point (O), metering process (M), exporting process (E),   and collecting process (C).  The observation points shown in the   figure are always the most fine-granular ones supported by the   respective device.         +---+     +-----+     +---------+       +---------+         | E-+->   |  E--+->   |    E----+->   <-+--E   E--+->         | | |     |  |  |     |   / \   |       |  |   |  |         | M |     |  M  |     |  M   M  |       |  M   M  |         | | |     | /|\ |     | /|\ /|\ |       | /|\ /|\ |         | O |     | OOO |     | OOO OOO |       | OOO OOO |         +---+     +-----+     +---------+       +---------+         Probe      Basic        Complex          Multiple                    Router       Router           Exporting                                                  Processes       +---+     +---+     +---+       | E-+->   | E-+->   | E-+------------->---+       | | |     | | |     | | | +---+         +-+-----+       +-+-+     | M |     | M | | E-+------->-+-C-M-E-+->         |       | | |     | | | | | | +---+   +-+-----+       +-+-+     +-+-+     | O | | M | | E-+->---+       | | |       |       +---+ | | | | | |       | M |     +-+-+           | O | | M |       | | |     | | |           +---+ | | |           +-----+       | O |     | O |                 | O |        ->-+-C-E-+->       +---+     +---+                 +---+           +-----+      Protocol   Remote             Concentrator        Proxy      Converter  Observation                   Figure 2: IPFIX-related Devices   A very simple device is a probe.  A typical probe contains a single   observation point, a single metering process, and a single exporting   process.   A basic router extends this structure by multiple observation points.   Here, the observation point of a particular flow may be one of the   displayed most fine-granular observation points, but also it may be a   set of them.   A more complex router may host more than one metering process, for   example one per line card.  Please note that here, the observation   point of a single flow cannot exceed the set of most fine-granular   observation points linked to a single metering process, because only   the metering process can merge packets observed at different fine-Quittek, et al.              Informational                     [Page 21]

RFC 3917                   IPFIX Requirements               October 2004   granular observation points to a joint flow.  An observation point   containing all most fine-granular observation points of this router   is not possible with this structure.  Alternatively, a complex router   may host different exporting processes for flow records generated by   different metering processes.   A protocol converter makes use of a metering process that can be   accessed only by protocol(s) other than the one defined for IPFIX,   for example, the SNMP and the Meter MIB module [RFC2720].  Then the   exporting process receives flow records from a remote metering   process and exports these records using the IPFIX protocol.  Please   note that this document does not make any particular assumption on   how metering processes and export processes exchange information, as   long as all individual requirements for these processes are met.   Also the locations of metering processes are not of any relevance for   this document (in contrast to the locations of observation points and   the exporting processes).   In the example of remote packet observation in Figure 2 the metering   process and the observation point are not co-located.  Packet headers   captured at an observation point may be exported as raw data to a   device hosting metering process and exporting process.  Again, this   document does not make any particular assumption on how packet   headers are transferred from observation points to metering   processes, as long as all requirements for the metering processes are   met.   An intermediate structure between protocol converter and remote   observation (not shown in the Figure) would be a split metering   process, for example performing timestamping and sampling at the   device hosting the observation point and performing packet   classification at another device hosting the exporting process.   A concentrator receives flow records via the IPFIX protocol, merges   them into more aggregated flow records, and exports them again using   the IPFIX protocol.  Please note that for the final flow records the   resulting observation point may be a superset of the more fine-   granular observation points at the first level devices.  The metering   process of the final flow records is composed by the (partial)   metering processes at the first level devices and the partial   metering process at the concentrator.   Finally, a very simple IPFIX-related device is a proxy.  It just   receives flow records using the IPFIX protocol and sends them further   using the same protocol.  A proxy might be useful for traversing   firewalls or other gateways.Quittek, et al.              Informational                     [Page 22]

RFC 3917                   IPFIX Requirements               October 200410.  Security Considerations   An IPFIX protocol must be capable of transporting data over the   public Internet.  Therefore it cannot be excluded that an attacker   captures or modifies packets or inserts additional packets.   This section describes security requirements for IPFIX.  Like other   requirements, the security requirements differ among the considered   applications.  The incentive to modify collected data for accounting   or intrusion detection for instance is usually higher than the   incentive to change data collected for traffic profiling.  A detailed   list of the required security features per application can be found   in the appendix.   The suggestion of concrete solutions for achieving the required   security properties should be part of an IPFIX architecture and   protocol.  It is out of scope of this document.  Also methods for   remote configuration of the metering processes and exporting   processes are out of scope.  Therefore, threats that are caused by   data exchange for remote configuration are not considered here.   The following potential security hazards for an IPFIX protocol have   been identified: disclosure of IP flow information, forgery of flow   records, and Denial of Service (DoS) attacks.10.1.  Disclosure of Flow Information Data   The content of data exchanged by an IPFIX protocol (for example IPFIX   flow records) should be kept confidential between the involved   parties (exporting process and collecting process).  Observation of   IPFIX flow records gives an attacker information about the active   flows in the network, communication endpoints and traffic patterns.   This information cannot only be used to spy on user behavior but also   to plan and conceal future attacks.  Therefore, the requirements   specified insection 6.3.3. include confidentiality of the   transferred data.  This can be achieved for instance by encryption.   Also the privacy of users acting as sender or receiver of the   measured traffic needs to be protected when they use the Internet.   In many countries the right to store user-specific data (including   the user's traffic profiles) is restricted by law or by regulations.   In addition to encryption, this kind of privacy can also be protected   by anonymizing flow records.  For many traffic flow measurements,   anonymized data is as useful as precise data.  Therefore, it is   desirable to support anonymization in IPFIX implementations.  It is   beyond the scope of the IPFIX Working Group to develop andQuittek, et al.              Informational                     [Page 23]

RFC 3917                   IPFIX Requirements               October 2004   standardize anonymization methods.  However, the requirements for   extensibility of the IPFIX protocol are sufficient to support   anonymized flow records when appropriate methods are standardized.10.2.  Forgery of Flow Records   If flow records are used in accounting and/or security applications,   there are potentially strong incentives to forge exported IPFIX flow   records (for example, to save money or prevent the detection of an   attack).  This can be done either by altering flow records on the   path or by injecting forged flow records that pretend to be   originated by the original exporting process.   Special caution is required if security applications rely on flow   measurements.  With forged flow records it is possible to trick   security applications.  For example, an application may be lead to   falsely conclude that a DoS attack is in progress.  If such an   injection of IPFIX traffic flow records fools the security   application, causing it to erroneously conclude that a DoS attack is   underway, then the countermeasures employed by the security   application may actually deny useful non-malicious services.   In order to make an IPFIX protocol resistant against such attacks,   authentication and integrity must be provided, as specified insection 6.3.3.10.3.  Denial of Service (DoS) Attacks   DoS attacks on routers or other middleboxes that have the IPFIX   protocol implemented would also affect the IPFIX protocol and impair   the sending of IPFIX records.  Nevertheless, since such hazards are   not induced specifically by the IPFIX protocol the prevention of such   attacks is out of scope of this document.   However, IPFIX itself also causes potential hazards for DoS attacks.   All processes that expect the reception of traffic can be target of a   DoS attack.  With the exporting process this is only the case if it   supports the pull mode (which can be an optional feature of the IPFIX   protocol according to this document).  The collecting process always   expects data and therefore can be flooded by flow records.Quittek, et al.              Informational                     [Page 24]

RFC 3917                   IPFIX Requirements               October 200411.  Acknowledgments   Many thanks to Georg Carle for contributing to the application   analysis, to K.C. Norseth for several fine-tunings, to Sandra   Tartarelli for checking the appendix, and to a lot of people on the   mailing list for providing valuable comments and suggestions   including Nevil Brownlee, Carter Bullard, Paul Calato, Ram Gopal, Tal   Givoly, Jeff Meyer, Reinaldo Penno, Sonia Panchen, Simon Leinen,   David Plonka, Ganesh Sadasivan, Kevin Zhang, and many more.Quittek, et al.              Informational                     [Page 25]

RFC 3917                   IPFIX Requirements               October 200412.  Appendix: Derivation of Requirements from Applications   The following table documents, how the requirements stated in   sections3-7 are derived from requirements of the applications listed   insection 2.   Used abbreviations:      M = must      S = should      O = may (optional)      - = DONT CARE-----------------------------------------------------------------------.   IPFIX                                                               |----------------------------------------------------------------.      |E: QoS Monitoring                                               |      |----------------------------------------------------------.     |      |D: Attack/Intrusion Detection                             |     |      |----------------------------------------------------.     |     |      |C: Traffic Engineering                              |     |     |      |----------------------------------------------.     |     |     |      |B: Traffic Profiling                          |     |     |     |      |----------------------------------------.     |     |     |     |      |A: Usage-based Accounting               |     |     |     |     |      |----------------------------------.     |     |     |     |     |      |                                  |     |     |     |     |     |      || Sect. |    Requirement          |  A  |  B  |  C  |  D  |  E  | IPFIX||-------+-------------------------+-----+-----+-----+-----+-----+------|| 4.    | DISTINGUISHING FLOWS                                         ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 4.    | Combination of          |  M  |  M  |  M  |  M  |  M  |  M   ||       | required attributes     |     |     |     |     |     |      ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 4.1.  | in/out IF               |  S  |  M  |  M  |  S  |  S  |  M   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 4.2.  | src/dst address         |  M  |  M  |  M  |  M  |  M  |  M   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 4.2.  | Masking of IP addresses |  M  |  M  |  M  |  M  |  M  |  M   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 4.2.  | transport protocol      |  M  |  M  |  -  |  M  |  M  |  M   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 4.2.  | version field           |  -  |  S  |  S  |  O  |  O  |  S   ||       |                         |     |     | (b) |     |     |      ||-------+-------------------------+-----+-----+-----+-----+-----+------|Quittek, et al.              Informational                     [Page 26]

RFC 3917                   IPFIX Requirements               October 2004|-------+-------------------------+-----+-----+-----+-----+-----+------|| Sect. |    Requirement          |  A  |  B  |  C  |  D  |  E  | IPFIX||-------+-------------------------+-----+-----+-----+-----+-----+------|| 4.3.  | src/dst port            |  M  |  M  |  -  |  M  |  M  |  M   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 4.4.  | MPLS label (a)          |  S  |  S  |  M  |  O  |  S  |  M   ||       |                         |     |     | (c) |     |     |      ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 4.5.  | DSCP (a)                |  M  |  S  |  M  |  O  |  M  |  M   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 5.    | METERING PROCESS                                             ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 5.1.  | Reliability             |  M  |  S  |  S  |  S  |  S  |      ||-------+-------------------------+-----+-----+-----+-----+-----+  M   || 5.1.  | Indication of           |  -  |  M  |  M  |  M  |  M  |      ||       | missing reliability     |     |     |     |     |     |      ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 5.2.  | Sampling (d,e)          |  O  |  O  |  O  |  O  |  O  |  O   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 5.3.  | Overload Behavior (f)   |  O  |  O  |  O  |  O  |  O  |  O   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 5.4.  | Timestamps              |  M  |  O  |  O  |  S  |  M  |  M   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 5.5.  | Time synchronization    |  M  |  S  |  S  |  S  |  M  |  M   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 5.6.  | Flow timeout            |  M  |  S  |  -  |  O  |  O  |  M   ||       |                         | (g) |     |     |     |     |      ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 5.7.  | Multicast flows         |  S  |  O  |  O  |  O  |  S  |  S   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 5.8.  | Packet fragmentation    |  O  |  O  |  -  |  -  |  -  |  O   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 5.9.  | Ignore port copy        |  O  |  O  |  O  |  O  |  O  |  O   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.    | DATA EXPORT                                                  ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.1.  | INFORMATION MODEL                                            ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.1.  | IP Version              |  -  |  M  |  M  |  O  |  O  |  M   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.1.  | src/dst address         |  M  |  M  |  M  |  M  |  M  |  M   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.1.  | transport protocol      |  M  |  M  |  -  |  M  |  M  |  M   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.1.  | src/dst port            |  M  |  M  |  -  |  M  |  M  |  M   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.1.  | Packet counter (h)      |  S  |  M  |  M  |  S  |  S  |  M   ||-------+-------------------------+-----+-----+-----+-----+-----+------|Quittek, et al.              Informational                     [Page 27]

RFC 3917                   IPFIX Requirements               October 2004|-------+-------------------------+-----+-----+-----+-----+-----+------|| Sect. |    Requirement          |  A  |  B  |  C  |  D  |  E  | IPFIX||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.1.  | Byte counter            |  M  |  M  |  M  |  S  |  S  |  M   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.1.  | ToS (IPv4) or traffic   |  M  |  S  |  M  |  O  |  M  |  M   ||       | class octet (IPv6)      |     |     |     |     |     |      ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.1.  | Flow Label (IPv6)       |  M  |  S  |  M  |  O  |  M  |  M   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.1.  | MPLS label (a)          |  S  |  S  |  M  |  O  |  S  |  M   ||       |                         |     |     | (c) |     |     |      ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.1.  | Timestamps for          |  M  |  O  |  O  |  S  |  S  |  M   ||       | first/last packet       |     |     |     |     |     |      ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.1.  | Sampling configuration  |  M  |  M  |  M  |  M  |  M  |  M   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.1.  | observation point       |  M  |  M  |  M  |  M  |  M  |  M   ||       | identifier              |     |     |     |     |     |      ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.1.  | export process          |  M  |  M  |  M  |  M  |  M  |  M   ||       | identifier              |     |     |     |     |     |      ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.1.  | ICMP type and code (i)  |  S  |  S  |  -  |  S  |  S  |  S   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.1.  | input/output interface  |  S  |  S  |  S  |  S  |  S  |  S   ||       | (j)                     |     |     |     |     |     |      ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.1.  | Multicast               |  O  |  S  |  S  |  -  |  S  |  S   ||       | replication factor      |     |     |     |     |     |      ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.1.  | TTL                     |  O  |  O  |  O  |  O  |  O  |  O   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.1.  | IP header flags         |  -  |  O  |  O  |  O  |  O  |  O   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.1.  | TCP header flags        |  -  |  O  |  O  |  O  |  -  |  O   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.1.  | Dropped Packet          |  O  |  O  |  O  |  O  |  O  |  O   ||       | Counter (h,k)           |     |     |     |     |     |      ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.1.  | Fragment counter        |  -  |  O  |  O  |  O  |  O  |  O   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.1.  | next hop IP address     |  O  |  O  |  O  |  O  |  -  |  O   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.1.  | src / dst / next hop    |  -  |  O  |  O  |  -  |  -  |  O   ||       | BGP AS #                |     |     |     |     |     |      ||-------+-------------------------+-----+-----+-----+-----+-----+------|Quittek, et al.              Informational                     [Page 28]

RFC 3917                   IPFIX Requirements               October 2004|-------+-------------------------+-----+-----+-----+-----+-----+------|| Sect. |    Requirement          |  A  |  B  |  C  |  D  |  E  | IPFIX||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.2.  | DATA MODEL                                                   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.2.  | Flexibility             |  M  |  S  |  M  |  M  |  M  |  M   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.2.  | Extensibility           |  M  |  S  |  M  |  M  |  M  |  M   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.3.  | DATA TRANSFER                                                ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.3.1.| Congestion aware        |  M  |  M  |  M  |  M  |  M  |  M   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.3.2.| Reliability             |  M  |  S  |  S  |  S  |  S  |  M   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.3.3.| Confidentiality         |  M  |  S  |  S  |  M  |  S  |  M   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.3.4.| Integrity               |  M  |  M  |  M  |  M  |  M  |  M   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.3.5.| Authenticity            |  M  |  M  |  M  |  M  |  M  |  M   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.4.  | REPORTING TIMES                                              ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.4.  | Push mode               |  M  |  O  |  O  |  M  |  S  |  M   ||       |                         |     | (l) | (l) |     |(l,m)|      ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.4.  | Pull mode               |  O  |  O  |  O  |  O  |  O  |  O   ||       |                         |     | (l) | (l) |     | (l) |      ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.4.1.| Regular interval        |  S  |  S  |  S  |  S  |  S  |  S   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.6.  | Notifications           |  O  |  O  |  O  |  O  |  O  |  O   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 6.7.  | Anonymization (n)       |  O  |  O  |  O  |  O  |  O  |  O   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 7.    | CONFIGURATION                                                ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 7.    | Secure remote           |  S  |  S  |  S  |  S  |  S  |  S   ||       | configuration (a)       |     |     |     |     |     |      ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 7.1.  | Config observation point|  S  |  S  |  S  |  S  |  S  |  S   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 7.1.  | Config flow             |  S  |  S  |  S  |  S  |  S  |  S   ||       | specifications          |     |     |     |     |     |      ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 7.1.  | Config flow timeouts    |  S  |  S  |  S  |  S  |  O  |  S   ||-------+-------------------------+-----+-----+-----+-----+-----+------|Quittek, et al.              Informational                     [Page 29]

RFC 3917                   IPFIX Requirements               October 2004|-------+-------------------------+-----+-----+-----+-----+-----+------|| Sect. |    Requirement          |  A  |  B  |  C  |  D  |  E  | IPFIX||-------+-------------------------+-----+-----+-----+-----+-----+------|| 7.1.  | Config sampling         |  O  |  O  |  O  |  O  |  O  |  O   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 7.1.  | Config overload         |  O  |  O  |  O  |  O  |  O  |  O   ||       | behavior (a)            |     |     |     |     |     |      ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 7.2.  | Config report           |  S  |  S  |  S  |  S  |  S  |  S   ||       | data format             |     |     |     |     |     |      ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 7.2.  | Config                  |  S  |  S  |  S  |  S  |  S  |  S   ||       | notifications           |     |     |     |     |     |      ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 8.    | GENERAL REQUIREMENTS                                         ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 8.1.  | Openness                |  S  |  S  |  S  |  S  |  S  |  S   ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 8.2.  | Scalability:            |     |     |     |     |     |      ||       | data collection         |  M  |  S  |  M  |  O  |  S  |  M   ||       | from hundreds of        |     |     |     |     |     |      ||       | measurement devices     |     |     |     |     |     |      ||-------+-------------------------+-----+-----+-----+-----+-----+------|| 8.3.  | Several collectors      |  O  |  O  |  O  |  O  |  O  |  O   ||-------+-------------------------+-----+-----+-----+-----+-----+------|   Remarks:      (a) If feature is supported.      (b) The differentiation of IPv4 and IPv6 is for TE of importance.          So we tended to make this a must.  Nevertheless, a should          seems to be sufficient to perform most TE tasks and allows us          to have a should for IPFIX instead of a must.      (c) For TE in an MPLS network the label is essential.  Therefore a          must is given here leading to a must in IPFIX.      (d) If sampling is supported, the methods and parameters must be          well defined.      (e) If sampling is supported, sampling configuration changes must          be indicated to all collecting processes.      (f) If overload behavior is supported and it induces changes in          the metering process behavior, the overload behavior must be          clearly defined.      (g) Precise time-based accounting requires reaction to a flow          timeout.      (h) If a packet is fragmented, each fragment is counted as an          individual packet.      (i) If protocol type is ICMP.Quittek, et al.              Informational                     [Page 30]

RFC 3917                   IPFIX Requirements               October 2004      (j) This requirement does not apply if the observation point is          located at a probe device.      (k) Only if measurement is done on data path i.e., has access to          forwarding decision.      (l) Either push or pull has to be supported.      (m) Required, in order to immediately report drop indications for          SLA validation.      (n) Anonymization must be clearly indicated to all receiving          collecting processes.13.  References13.1.  Normative References   [RFC2960]   Stewart, R., Xie, Q., Morneault, K., Sharp, C.,               Schwarzbauer, H., Taylor, T., Rytina, I., Kalla, M.,               Zhang, L., and V. Paxson, "Stream Control Transmission               Protocol",RFC 2960, October 2000.   [RFC3031]   Rosen, E., Viswanathan, A., and R. Callon, "Multiprotocol               Label Switching Architecture",RFC 3031, January 2001.   [RFC2474]   Nichols, K., Blake, S., Baker, F., and D. Black,               "Definition of the Differentiated Services Field (DS               Field) in the IPv4 and IPv6 Headers",RFC 2474, December               1998.   [RFC791]    Postel, J., "Internet Protocol", STD 5,RFC 791,               September 1981.13.2.  Informative References   [RFC3234]   Carpenter, B. and S. Brim, "Middleboxes: Taxonomy and               Issues",RFC 3234, February 2002.   [RFC2119]   Bradner, S., "Key words for use in RFCs to Indicate               Requirement Levels",BCP 14,RFC 2119, March 1997.   [RFC3550]   Schulzrinne, H.,  Casner, S., Frederick, R., and V.               Jacobson, "RTP: A Transport Protocol for Real-Time               Applications", STD 64,RFC 3550, July 2003.   [RFC2975]   Aboba, B., Arkko, J., and D. Harrington, "Introduction to               Accounting Management",RFC 2975, October 2000.   [RFC2702]   Awduche, D., Malcolm, J., Agogbua, J., O'Dell, M., and J.               McManus, "Requirements for Traffic Engineering Over               MPLS",RFC 2702, September 1999.Quittek, et al.              Informational                     [Page 31]

RFC 3917                   IPFIX Requirements               October 2004   [RFC1771]   Rekhter, Y. and T. Li, "A Border Gateway Protocol 4               (BGP-4)",RFC 1771, March 1995.   [RFC3418]   Presuhn, R., "Management Information Base (MIB) for the               Simple Network Management Protocol (SNMP)", STD 62,RFC3418, December 2002.   [RFC2720]   Brownlee, N., "Traffic Flow Measurement: Meter MIB",RFC2720, October 1999.14.  Authors' Addresses   Juergen Quittek   NEC Europe Ltd., Network Laboratories   Kurfuersten-Anlage 36   69115 Heidelberg   Germany   Phone: +49 6221 90511 15   EMail: quittek@netlab.nec.de   Tanja Zseby   Fraunhofer Institute for Open Communication Systems (FOKUS)   Kaiserin-Augusta-Allee 31   10589 Berlin   Germany   Phone: +49 30 3463 7153   EMail: zseby@fokus.fhg.de   Benoit Claise   Cisco Systems   De Kleetlaan 6a b1   1831 Diegem   Belgium   Phone: +32 2 704 5622   EMail: bclaise@cisco.com   Sebastian Zander   Centre for Advanced Internet Architectures, Mail H31   Swinburne University of Technology   PO Box 218   John Street, Hawthorn   Victoria 3122, Australia   Phone: +61 3 9214 8089   EMail: szander@swin.edu.auQuittek, et al.              Informational                     [Page 32]

RFC 3917                   IPFIX Requirements               October 200415.  Full Copyright Statement   Copyright (C) The Internet Society (2004).   This document is subject to the rights, licenses and restrictions   contained inBCP 78, and except as set forth therein, the authors   retain all their rights.   This document and the information contained herein are provided on an   "AS IS" basis and THE CONTRIBUTOR, THE ORGANIZATION HE/SHE REPRESENTS   OR IS SPONSORED BY (IF ANY), THE INTERNET SOCIETY AND THE INTERNET   ENGINEERING TASK FORCE DISCLAIM ALL WARRANTIES, EXPRESS OR IMPLIED,   INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE   INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED   WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.Intellectual Property   The IETF takes no position regarding the validity or scope of any   Intellectual Property Rights or other rights that might be claimed to   pertain to the implementation or use of the technology described in   this document or the extent to which any license under such rights   might or might not be available; nor does it represent that it has   made any independent effort to identify any such rights.  Information   on the IETF's procedures with respect to rights in IETF Documents can   be found inBCP 78 andBCP 79.   Copies of IPR disclosures made to the IETF Secretariat and any   assurances of licenses to be made available, or the result of an   attempt made to obtain a general license or permission for the use of   such proprietary rights by implementers or users of this   specification can be obtained from the IETF on-line IPR repository athttp://www.ietf.org/ipr.   The IETF invites any interested party to bring to its attention any   copyrights, patents or patent applications, or other proprietary   rights that may cover technology that may be required to implement   this standard.  Please address the information to the IETF at ietf-   ipr@ietf.org.Acknowledgement   Funding for the RFC Editor function is currently provided by the   Internet Society.Quittek, et al.              Informational                     [Page 33]