Internet Engineering Task Force (IETF)                          J. NovakRequest for Comments: 6645                           Cisco Systems, Inc.Category: Informational                                        July 2012ISSN: 2070-1721IP Flow Information Accounting andExport Benchmarking MethodologyAbstract   This document provides a methodology and framework for quantifying   the performance impact of the monitoring of IP flows on a network   device and the export of this information to a Collector.  It   identifies the rate at which the IP flows are created, expired, and   successfully exported as a new performance metric in combination with   traditional throughput.  The metric is only applicable to the devices   compliant withRFC 5470, "Architecture for IP Flow Information   Export".  The methodology quantifies the impact of the IP flow   monitoring process on the network equipment.Status of This Memo   This document is not an Internet Standards Track specification; it is   published for informational purposes.   This document is a product of the Internet Engineering Task Force   (IETF).  It represents the consensus of the IETF community.  It has   received public review and has been approved for publication by the   Internet Engineering Steering Group (IESG).  Not all documents   approved by the IESG are a candidate for any level of Internet   Standard; seeSection 2 of RFC 5741.   Information about the current status of this document, any   errata, and how to provide feedback on it may be obtained athttp://www.rfc-editor.org/info/rfc6645.Novak                         Informational                     [Page 1]

RFC 6645              Flow Monitoring Benchmarking             July 2012Copyright Notice   Copyright (c) 2012 IETF Trust and the persons identified as the   document authors.  All rights reserved.   This document is subject toBCP 78 and the IETF Trust's Legal   Provisions Relating to IETF Documents   (http://trustee.ietf.org/license-info) in effect on the date of   publication of this document.  Please review these documents   carefully, as they describe your rights and restrictions with respect   to this document.  Code Components extracted from this document must   include Simplified BSD License text as described in Section 4.e of   the Trust Legal Provisions and are provided without warranty as   described in the Simplified BSD License.Novak                         Informational                     [Page 2]

RFC 6645              Flow Monitoring Benchmarking             July 2012Table of Contents1. Introduction ....................................................42. Terminology .....................................................52.1. Existing Terminology .......................................52.2. New Terminology ............................................63. Flow Monitoring Performance Benchmark ...........................83.1. Definition .................................................83.2. Device Applicability .......................................83.3. Measurement Concept ........................................83.4. The Measurement Procedure Overview .........................94. Measurement Setup ..............................................114.1. Measurement Topology ......................................114.2. Baseline DUT Setup ........................................134.3. Flow Monitoring Configuration .............................134.4. Collector .................................................194.5. Sampling ..................................................194.6. Frame Formats .............................................194.7. Frame Sizes ...............................................204.8. Flow Export Data Packet Sizes .............................204.9. Illustrative Test Setup Examples ..........................205. Flow Monitoring Throughput Measurement Methodology .............225.1. Flow Monitoring Configuration .............................235.2. Traffic Configuration .....................................245.3. Cache Population ..........................................255.4. Measurement Time Interval .................................255.5. Flow Export Rate Measurement ..............................265.6. The Measurement Procedure .................................276.RFC 2544 Measurements ..........................................286.1. Flow Monitoring Configuration..............................286.2. Measurements with the Flow Monitoring Throughput Setup ....296.3. Measurements with Fixed Flow Export Rate...................297. Flow Monitoring Accuracy .......................................308. Evaluating Flow Monitoring Applicability .......................319. Acknowledgements ...............................................3210. Security Considerations .......................................3211. References ....................................................3311.1. Normative References .....................................3311.2. Informative References ...................................33Appendix A. Recommended Report Format .............................35Appendix B. Miscellaneous Tests ...................................36B.1. DUT Under Traffic Load ...................................36B.2. In-Band Flow Export ......................................36B.3. Variable Packet Rate .....................................37B.4. Bursty Traffic ...........................................37B.5. Various Flow Monitoring Configurations ...................38B.6. Tests with Bidirectional Traffic .........................38B.7. Instantaneous Flow Export Rate ...........................39Novak                         Informational                     [Page 3]

RFC 6645              Flow Monitoring Benchmarking             July 20121.  Introduction   Monitoring IP flows (Flow monitoring) is defined in the "Architecture   for IP Flow Information Export" [RFC5470] and related IPFIX documents   specified inSection 1.2 of [RFC5470].  It analyzes the traffic using   predefined fields from the packet header as keys and stores the   traffic and other internal information in the DUT (Device Under Test)   memory.  This cached flow information is then formatted into records   (seeSection 2.1 for term definitions) and exported from the DUT to   an external data collector for analysis.  More details on the   measurement architecture are provided inSection 3.3.   Flow monitoring on network devices is widely deployed and has   numerous uses in both service-provider and enterprise segments as   detailed in the "Requirements for IP Flow Information Export (IPFIX)"   [RFC3917].  This document provides a methodology for measuring Flow   monitoring performance so that network operators have a framework to   measure the impact on the network and network equipment.   This document's goal is to provide a series of methodology   specifications for the measurement of Flow monitoring performance in   a way that is comparable amongst various implementations, platforms,   and vendor devices.   Flow monitoring is, in most cases, run on network devices that also   forward packets.  Therefore, this document also provides the   methodology for [RFC2544] measurements in the presence of Flow   monitoring.  It is applicable to IPv6 and MPLS traffic with their   specifics defined in [RFC5180] and [RFC5695], respectively.   This document specifies a methodology to measure the maximum IP Flow   Export Rate that a network device can sustain without impacting the   Forwarding Plane, without losing any IP flow information and without   compromising IP flow accuracy (seeSection 7 for details).   [RFC2544], [RFC5180], and [RFC5695] specify benchmarking of network   devices forwarding IPv4, IPv6, and MPLS [RFC3031] traffic,   respectively.  The methodology specified in this document stays the   same for any traffic type.  The only restriction may be the DUT's   lack of support for Flow monitoring of a particular traffic type.   A variety of different DUT architectures exist that are capable of   Flow monitoring and export.  As such, this document does not attempt   to list the various white-box variables (e.g., CPU load, memory   utilization, hardware resources utilization, etc.) that could be   gathered as they always help in comparison evaluations.  A more   complete understanding of the stress points of a particular deviceNovak                         Informational                     [Page 4]

RFC 6645              Flow Monitoring Benchmarking             July 2012   can be attained using this internal information, and the tester MAY   choose to gather this information during the measurement iterations.2.  Terminology   The terminology used in this document is based on that defined in   [RFC5470], [RFC2285], and [RFC1242], as summarized inSection 2.1.   The only new terms needed for this methodology are defined inSection2.2.   Additionally, the key words "MUST", "MUST NOT", "REQUIRED", "SHALL",   "SHALL NOT", "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and   "OPTIONAL" in this document are to be interpreted as described  inRFC 2119 [RFC2119].2.1.  Existing Terminology    Device Under Test (DUT)   [RFC2285,Section 3.1.1]    Flow                      [RFC5101,Section 2]    Flow Key                  [RFC5101,Section 2]    Flow Record               [RFC5101,Section 2]    Template Record           [RFC5101,Section 2]    Observation Point         [RFC5470,Section 2]    Metering Process          [RFC5470,Section 2]    Exporting Process         [RFC5470,Section 2]    Exporter                  [RFC5470,Section 2]    Collector                 [RFC5470,Section 2]    Control Information       [RFC5470,Section 2]    Data Stream               [RFC5470,Section 2]    Flow Expiration           [RFC5470,Section 5.1.1]    Flow Export               [RFC5470,Section 5.1.2]    Throughput                [RFC1242,Section 3.17]Novak                         Informational                     [Page 5]

RFC 6645              Flow Monitoring Benchmarking             July 20122.2.  New Terminology2.2.1.  Cache   Definition:      Memory area held and dedicated by the DUT to store Flow      information prior to the Flow Expiration.2.2.2.  Cache Size   Definition:      The size of the Cache in terms of how many entries the Cache can      hold.   Discussion:      This term is typically represented as a configurable option in the      particular Flow monitoring implementation.  Its highest value will      depend on the memory available in the network device.   Measurement units:      Number of Cache entries2.2.3.  Active Timeout   Definition:      For long-running Flows, the time interval after which the Metering      Process expires a Cache entry to ensure Flow data is regularly      updated.   Discussion:      This term is typically presented as a configurable option in the      particular Flow monitoring implementation.  SeeSection 5.1.1 of      [RFC5470] for a more detailed discussion.      Flows are considered long running when they last longer than      several multiples of the Active Timeout.  If the Active Timeout is      zero, then Flows are considered long running if they contain many      more packets (tens of packets) than usually observed in a single      transaction.   Measurement units:      SecondsNovak                         Informational                     [Page 6]

RFC 6645              Flow Monitoring Benchmarking             July 20122.2.4.  Idle Timeout   Definition:      The time interval used by the Metering Process to expire an entry      from the Cache when no more packets belonging to that specific      Cache entry have been observed during the interval.   Discussion:      Idle Timeout is typically represented as a configurable option in      the particular Flow monitoring implementation.  SeeSection 5.1.1      of [RFC5470] for more detailed discussion.  Note that some      documents in the industry refer to "Idle Timeout" as "inactive      timeout".   Measurement units:      Seconds2.2.5.  Flow Export Rate   Definition:      The number of Cache entries that expire from the Cache (as defined      by the Flow Expiration term) and are exported to the Collector      within a measurement time interval.  There SHOULD NOT be any      export filtering, so that all the expired Cache entries are      exported.  If there is export filtering and it can't be disabled,      this MUST be indicated in the measurement report.      The measured Flow Export Rate MUST include both the Data Stream      and the Control Information, as defined inSection 2 of [RFC5470].   Discussion:      The Flow Export Rate is measured using Flow Export data observed      at the Collector by counting the exported Flow Records during the      measurement time interval (seeSection 5.4).  The value obtained      is an average of the instantaneous export rates observed during      the measurement time interval.  The smallest possible measurement      interval (if attempting to measure a nearly instantaneous export      rate rather than average export rate on the DUT) is limited by the      export capabilities of the particular Flow monitoring      implementation (when physical-layer issues between the DUT and the      Collector are excluded).   Measurement units:      Number of Flow Records per secondNovak                         Informational                     [Page 7]

RFC 6645              Flow Monitoring Benchmarking             July 20123.  Flow Monitoring Performance Benchmark3.1.  Definition   Flow Monitoring Throughput   Definition:      The maximum Flow Export Rate the DUT can sustain without losing a      single Cache entry.  Additionally, for packet forwarding devices,      the maximum Flow Export Rate the DUT can sustain without dropping      packets in the Forwarding Plane (see Figure 1).   Measurement units:      Number of Flow Records per second   Discussion:      The losses of Cache entries, or forwarded packets per this      definition are assumed to happen due to the lack of DUT resources      to process any additional traffic information or lack of resources      to process Flow Export data.  The physical-layer issues, like      insufficient bandwidth from the DUT to the Collector or lack of      Collector resources, MUST be excluded as detailed inSection 4.3.2.  Device Applicability   The Flow monitoring performance metric is applicable to network   devices that deploy the architecture described in [RFC5470].  These   devices can be network packet forwarding devices or appliances that   analyze traffic but do not forward traffic (e.g., probes, sniffers,   replicators).   This document does not intend to measure Collector performance, it   only requires sufficient Collector resources (as specified inSection4.4) in order to measure the DUT characteristics.3.3.  Measurement Concept   Figure 1 presents the functional block diagram of the DUT.  The   traffic in the figure represents test traffic sent to the DUT and   forwarded by the DUT, if possible.  When testing devices that do not   act as network packet forwarding devices (such as probes, sniffers,   and replicators), the Forwarding Plane is simply an Observation Point   as defined inSection 2 of [RFC5470].  The Throughput of such devices   will always be zero, and the only applicable performance metric is   the Flow Monitoring Throughput.  Netflow is specified by [RFC3954].Novak                         Informational                     [Page 8]

RFC 6645              Flow Monitoring Benchmarking             July 2012              +------------------------- +              | IPFIX | NetFlow | Others |              +------------------------- +              |            ^             |              |       Flow Export        |              |            ^             |              |     +-------------+      |              |     | Monitoring  |      |              |     |   Plane     |      |              |     +-------------+      |              |            ^             |              |     traffic information  |              |            ^             |              |     +-------------+      |              |     |             |      |   traffic ---|---->| Forwarding  |------|---->              |     |    Plane    |      |              |     +-------------+      |              |                          |              |           DUT            |              +------------------------- +   Figure 1.  The Functional Block Diagram of the DUT   Flow monitoring is represented in Figure 1 by the Monitoring Plane;   it is enabled as specified inSection 4.3.  It uses the traffic   information provided by the Forwarding Plane and configured Flow Keys   to create Cache entries representing the traffic forwarded (or   observed) by the DUT in the DUT Cache.  The Cache entries are expired   from the Cache depending on the Cache configuration (e.g., the Active   and Idle Timeouts, the Cache Size), number of Cache entries, and the   traffic pattern.  The Cache entries are used by the Exporting Process   to format the Flow Records, which are then exported from the DUT to   the Collector (see Figure 2 inSection 4).   The Forwarding Plane and Monitoring Plane represent two separate   functional blocks, each with its own performance capability.  The   Forwarding Plane handles user data packets and is fully characterized   by the metrics defined by [RFC1242].   The Monitoring Plane handles Flows that reflect the analyzed traffic.   The metric for Monitoring Plane performance is the Flow Export Rate,   and the benchmark is the Flow Monitoring Throughput.3.4.  The Measurement Procedure Overview   The measurement procedure is fully specified in Sections4,5, and6.   This section provides an overview of principles for the measurements.Novak                         Informational                     [Page 9]

RFC 6645              Flow Monitoring Benchmarking             July 2012   The basic measurement procedure of the performance characteristics of   a DUT with Flow monitoring enabled is a conventional Throughput   measurement using a search algorithm to determine the maximum packet   rate at which none of the offered packets and corresponding Flow   Records are dropped by the DUT as described in [RFC1242] andSection26.1 of [RFC2544].   The DUT with Flow monitoring enabled contains two functional blocks   that need to be measured using characteristics applicable to one or   both blocks (see Figure 1).  See Sections3.4.1 and3.4.2 for further   discussion.   On one hand, the Monitoring Plane and Forwarding Plane (see Figure 1)   need to be looked at as two independent blocks, and the performance   of each measured independently.  On the other hand, when measuring   the performance of one, the status and performance of the other MUST   be known and benchmarked when both are present.3.4.1.  Monitoring Plane Performance Measurement   The Flow Monitoring Throughput MUST be (and can only be) measured   with one packet per Flow as specified inSection 5.  This traffic   type represents the most demanding traffic from the Flow monitoring   point of view and will exercise the Monitoring Plane (see Figure 1)   of the DUT most.  In this scenario, every packet seen by the DUT   creates a new Cache entry and forces the DUT to fill the Cache   instead of just updating the packet and byte counters of an already   existing Cache entry.   The exit criteria for the Flow Monitoring Throughput measurement are   one of the following (e.g., if any of the conditions are reached):   a. The Flow Export Rate at which the DUT starts to lose Flow      Information or the Flow Information gets corrupted.   b. The Flow Export Rate at which the Forwarding Plane starts to drop      or corrupt packets (if the Forwarding Plane is present).   A corrupted packet here means packet header corruption (resulting in   the cyclic redundancy check failure on the transmission level and   consequent packet drop) or packet payload corruption, which leads to   lost application-level data.3.4.2.  Forwarding Plane Performance Measurement   The Forwarding Plane (see Figure 1) performance metrics are fully   specified by [RFC1242] and MUST be measured accordingly.  A detailed   traffic analysis (see below) with relation to Flow monitoring MUST beNovak                         Informational                    [Page 10]

RFC 6645              Flow Monitoring Benchmarking             July 2012   performed prior of any [RFC2544] measurements.  Most importantly, the   Flow Export Rate caused by the test traffic during an [RFC2544]   measurement MUST be known and reported.   The required test traffic analysis mainly involves the following:   a. Which packet header parameters are incremented or changed during      traffic generation.   b. Which Flow Keys the Flow monitoring configuration uses to generate      Flow Records.   The performance metrics described inRFC 1242 can be measured in one   of the three modes:   a. As a baseline of forwarding performance without Flow monitoring.   b. At a certain level of Flow monitoring activity specified by a Flow      Export Rate lower than the Flow Monitoring Throughput.   c. At the maximum level of Flow monitoring performance, e.g., using      traffic conditions representing a measurement of Flow Monitoring      Throughput.   The above mentioned measurement mode in point a.  represents an   ordinary Throughput measurement specified inRFC 2544.  The details   of how to set up the measurements in points b. and c. are given inSection 6.4.  Measurement Setup   This section concentrates on the setup of all components necessary to   perform Flow monitoring performance measurement.  The recommended   reporting format can be found inAppendix A.4.1.  Measurement Topology   The measurement topology described in this section is applicable only   to the measurements with packet forwarding network devices.  The   possible architectures and implementation of the traffic monitoring   appliances (seeSection 3.2) are too various to be covered in this   document.  Instead of the Forwarding Plane, these appliances   generally have some kind of feed (e.g., an optical splitter, an   interface sniffing traffic on a shared media, or an internal channel   on the DUT providing a copy of the traffic) providing the information   about the traffic necessary for Flow monitoring analysis.  The   measurement topology then needs to be adjusted to the appliance   architecture and MUST be part of the measurement report.Novak                         Informational                    [Page 11]

RFC 6645              Flow Monitoring Benchmarking             July 2012   The measurement setup is identical to that used by [RFC2544], with   the addition of a Collector to analyze the Flow Export (see Figure   2).   In the measurement topology with unidirectional traffic, the traffic   is transmitted from the sender to the receiver through the DUT.  The   received traffic is analyzed to check that it is identical to the   generated traffic.   The ideal way to implement the measurement is by using a single   device to provide the sender and receiver capabilities with one   sending port and one receiving port.  This allows for an easy check   as to whether all the traffic sent by the sender was re-transmitted   by the DUT and received at the receiver.                       +-----------+                       |           |                       | Collector |                       |           |                       |Flow Record|                       | analysis  |                       |           |                       +-----------+                             ^                             | Flow Export                             |                             | Export Interface   +--------+         +-------------+          +----------+   |        |         |             |          | traffic  |   | traffic|      (*)|             |          | receiver |   | sender |-------->|     DUT     |--------->|          |   |        |         |             |          | traffic  |   |        |         |             |          | analysis |   +--------+         +-------------+          +----------+   Figure 2.  Measurement Topology with Unidirectional Traffic   The DUT's export interface (connecting the Collector) MUST NOT be   used for forwarding test traffic but only for the Flow Export data   containing the Flow Records.  In all measurements, the export   interface MUST have enough bandwidth to transmit Flow Export data   without congestion.  In other words, the export interface MUST NOT be   a bottleneck during the measurement.   The traffic receiver MUST have sufficient resources to measure all   test traffic transferred successfully by the DUT.  This may be   checked through measurements with and without the DUT.Novak                         Informational                    [Page 12]

RFC 6645              Flow Monitoring Benchmarking             July 2012   Note that more complex topologies might be required.  For example, if   the effects of enabling Flow monitoring on several interfaces is of   concern, or the maximum speed of media transmission is less than the   DUT Throughput, the topology can be expanded with several input and   output ports.  However, the topology MUST be clearly written in the   measurement report.4.2.  Baseline DUT Setup   The baseline DUT setup and the way the setup is reported in the   measurement results is fully specified inSection 7 of [RFC2544].   The baseline DUT configuration might include other features, like   packet filters or quality of service on the input and/or output   interfaces, if there is the need to study Flow monitoring in the   presence of those features.  The Flow monitoring measurement   procedures do not change in this case.  Consideration needs to be   made when evaluating measurement results to take into account the   possible change of packet rates offered to the DUT and Flow   monitoring after application of the features to the configuration.   Any such feature configuration MUST be part of the measurement   report.   The DUT export interface (see Figure 2) SHOULD be configured with   sufficient output buffers to avoid dropping the Flow Export data due   to a simple lack of resources in the interface hardware.  The applied   configuration MUST be part of the measurement report.   The test designer has the freedom to run tests in multiple   configurations.  It is therefore possible to run both non-production   and real deployment configurations in the laboratory, according to   the needs of the tester.  All configurations MUST be part of the   measurement report.4.3.  Flow Monitoring Configuration   This section covers all of the aspects of the Flow monitoring   configuration necessary on the DUT in order to perform the Flow   monitoring performance measurement.  The necessary configuration has   a number of components (see [RFC5470]), namely Observation Points,   Metering Process, and Exporting Process as detailed below.   The DUT MUST support the Flow monitoring architecture as specified by   [RFC5470].  The DUT SHOULD support IPFIX [RFC5101] to allow a   meaningful results comparison due to the standardized export   protocol.Novak                         Informational                    [Page 13]

RFC 6645              Flow Monitoring Benchmarking             July 2012   The DUT configuration, any existing Cache, and Cache entries MUST be   erased before the application of any new configuration for the   currently executed measurement.4.3.1.  Observation Points   The Observation Points specify the interfaces and direction in which   the Flow monitoring traffic analysis is to be performed.   The (*) in Figure 2 designates the Observation Points in the default   configuration.  Other DUT Observation Points might be configured   depending on the specific measurement needs as follows:   a. ingress port/ports only   b. egress port/ports only   c. both ingress and egress   This test topology corresponds to unidirectional traffic only with   traffic analysis performed on the input and/or output interface.   Testing with bidirectional traffic is discussed inAppendix B.   Generally, the placement of Observation Points depends upon the   position of the DUT in the deployed network and the purpose of Flow   monitoring.  See [RFC3917] for detailed discussion.  The measurement   procedures are otherwise the same for all these possible   configurations.   In the case of both ingress and egress Flow monitoring being enabled   on one DUT, the resulting analysis should consider that each Flow   will be represented in the DUT Cache by two Flow Records (one for   each direction).  Therefore, the Flow Export will also contain those   two Flow Records.   If more than one Observation Point for one direction is defined on   the DUT, the traffic passing through each of the Observation Points   MUST be configured in such a way that it creates Flows and Flow   Records that do not overlap.  Each packet (or set of packets if   measuring more than one packet per Flow - seeSection 6.3.1) sent to   the DUT on different ports still creates one unique Flow Record.   The specific Observation Points and associated monitoring direction   MUST be included as part of the measurement report.4.3.2.  Metering Process   The Metering Process MUST be enabled in order to create the Cache in   the DUT and configure the Cache related parameters.Novak                         Informational                    [Page 14]

RFC 6645              Flow Monitoring Benchmarking             July 2012   The Cache Size available to the DUT MUST be known and taken into   account when designing the measurement as specified inSection 5.   Typically, the Cache Size will be present in the "show" commands of   the Flow monitoring process, in either the actual configuration or   the product documentation from the DUT vendor.  The Cache Size MUST   have a fixed value for the entire duration of the measurement.  This   method is not applicable to benchmarking any Flow monitoring   applications that dynamically change their Cache Size.   The configuration of the Metering Process MUST be included as part of   the measurement report.  For example, when a Flow monitoring   implementation uses timeouts to expire entries from the Cache, the   Cache's Idle and Active Timeouts MUST be known and taken into account   when designing the measurement as specified inSection 5.  If the   Flow monitoring implementation allows only timeouts equal to zero   (e.g., immediate timeout or non-existent Cache), then the measurement   conditions inSection 5 are fulfilled inherently without any   additional configuration.  The DUT simply exports information about   every packet immediately, subject to the Flow Export Rate definition   inSection 2.2.5.   If the Flow monitoring implementation allows configuration of   multiple Metering Processes on a single DUT, the exact configuration   of each process MUST be included in the measurement report.  Only   measurements with the same number of Metering Processes can be   compared.   The Cache Size and the Idle and Active Timeouts MUST be included in   the measurement report.4.3.3.  Exporting Process   The Exporting Process MUST be configured in order to export the Flow   Record data to the Collector.   The Exporting Process MUST be configured in such a way that all Flow   Records from all configured Observation Points are exported towards   the Collector, after the expiration policy, which is composed of the   Idle and Active Timeouts and Cache Size.   The Exporting Process SHOULD be configured with IPFIX [RFC5101] as   the protocol used to format the Flow Export data.  If the Flow   monitoring implementation does not support IPFIX, proprietary   protocols MAY be used.  Only measurements with the same export   protocol SHOULD be compared since the protocols may differ in their   export efficiency.  The export efficiency might also be influenced by   the Template Record used and the ordering of the individual export   fields within the template.Novak                         Informational                    [Page 15]

RFC 6645              Flow Monitoring Benchmarking             July 2012   The Template Records used by the tested implementations SHOULD be   analyzed and documented as part of the measurement report.  Ideally,   only tests with same Template Records should be compared.   Various Flow monitoring implementations might use different default   values regarding the export of Control Information [RFC5470];   therefore, the Flow Export corresponding to Control Information   SHOULD be analyzed and reported as a separate item on the measurement   report.  The export of Control Information SHOULD always be   configured consistently across all testing and configured to the   minimal possible value.  Ideally, just one set of Control Information   should be exported during each measurement.  Note that Control   Information includes options and Template Records [RFC5470].Section 10 of [RFC5101] andSection 8.1 of [RFC5470] discuss the   possibility of deploying various transport-layer protocols to deliver   Flow Export data from the DUT to the Collector.  The selected   protocol MUST be included in the measurement report.  Only benchmarks   with the same transport-layer protocol SHOULD be compared.  If the   Flow monitoring implementation allows the use of multiple transport-   layer protocols, each of the protocols SHOULD be measured in a   separate measurement run and the results reported independently in   the measurement report.   If a reliable transport protocol is used for the transmission of the   Flow Export data from the DUT, the configuration of the Transport   session MUST allow for non-blocking data transmission.  An example of   parameters to look at would be the TCP window size and maximum   segment size (MSS).  The most substantial transport-layer parameters   should be included in the measurement report.4.3.4.  Flow Records   A Flow Record contains information about a specific Flow observed at   an Observation Point.  A Flow Record contains measured properties of   the Flow (e.g., the total number of bytes for all the Flow packets)   and usually characteristic properties of the Flow (e.g., source IP   address).   The Flow Record definition is implementation specific.  A Flow   monitoring implementation might allow for only a fixed Flow Record   definition, based on the most common IP parameters in the IPv4 or   IPv6 headers -- for example, source and destination IP addresses, IP   protocol numbers, or transport-level port numbers.  Another   implementation might allow the user to define their own arbitrary   Flow Record to monitor the traffic.  The only requirement for the   measurements defined in this document is the need for a largeNovak                         Informational                    [Page 16]

RFC 6645              Flow Monitoring Benchmarking             July 2012   number of Cache entries in the Cache.  The Flow Keys needed to   achieve that will typically be source and destination IP addresses   and transport-level port numbers.   The recommended full IPv4, IPv6, or MPLS Flow Record is shown below.   The IP address indicates either IPv4 or IPv6, depending on the   traffic type being tested.  The Flow Record configuration is Flow   monitoring implementation-specific; therefore, the examples below   cannot provide an exact specification of individual entries in each   Flow Record.  The best set of key fields to use is left to the test   designer using the capabilities of the specific Flow monitoring   implementation.      Flow Keys:         Source IP address         Destination IP address         MPLS label (for MPLS traffic type only)         Transport-layer source port         Transport-layer destination port         IP protocol number (IPv6 next header)         IP type of service (IPv6 traffic class)      Other fields:         Packet counter         Byte counter      Table 1: Recommended Configuration   If the Flow monitoring allows for user-defined Flow Records, the   minimal Flow Record configurations allowing large numbers of Cache   entries are, for example:      Flow Keys:         Source IP address         Destination IP address      Other fields:         Packet counter   or:      Flow Keys:         Transport-layer source port         Transport-layer destination port      Other fields:         Packet counter      Table 2: User-Defined ConfigurationNovak                         Informational                    [Page 17]

RFC 6645              Flow Monitoring Benchmarking             July 2012   The Flow Record configuration MUST be clearly noted in the   measurement report.  The Flow Monitoring Throughput measurements on   different DUTs, or different Flow monitoring implementations, MUST be   only compared for exactly the same Flow Record configuration.4.3.5.  Flow Monitoring with Multiple Configurations   The Flow monitoring architecture as specified in [RFC5470] allows for   more complicated configurations with multiple Metering and Exporting   Processes on a single DUT.  Depending on the particular Flow   monitoring implementation, it might affect the measured DUT   performance.  Therefore, the measurement report should contain   information about how many Metering and Exporting Processes were   configured on the DUT for the selected Observation Points.   The examples of such possible configurations are:   a. Several Observation Points with a single Metering Process and a      single Exporting Process.   b. Several Observation Points, each with one Metering Process but all      using just one instance of Exporting Process.   c. Several Observation Points with per-Observation-Point Metering      Process and Exporting Process.4.3.6.  MPLS Measurement Specifics   The Flow Record configuration for measurements with MPLS encapsulated   traffic SHOULD contain the MPLS label.  For this document's purposes,   "MPLS Label" is the entire 4 byte MPLS header.  Typically, the label   of the interest will be at the top of the label stack, but this   depends on the details of the MPLS test setup.   The tester SHOULD ensure that the data received by the Collector   contains the expected MPLS labels.   The MPLS forwarding performance document [RFC5695] specifies a number   of possible MPLS label operations to test.  The Observation Points   MUST be placed on all the DUT test interfaces where the particular   MPLS label operation takes place.  The performance measurements   SHOULD be performed with only one MPLS label operation at the time.   The DUT MUST be configured in such a way that all the traffic is   subject to the measured MPLS label operation.Novak                         Informational                    [Page 18]

RFC 6645              Flow Monitoring Benchmarking             July 20124.4.  Collector   The Collector is needed in order to capture the Flow Export data,   which allows the Flow Monitoring Throughput to be measured.   The Collector can be used exclusively as a capture device, providing   just hexadecimal format of the Flow Export data.  In such a case, it   does not need to have any additional Flow Export decoding   capabilities and all the decoding is done offline.   However, if the Collector is also used to decode the Flow Export   data, it SHOULD support IPFIX [RFC5101] for meaningful results   analysis.  If proprietary Flow Export is deployed, the Collector MUST   support it; otherwise, the Flow Export data analysis is not possible.   The Collector MUST be capable of capturing the export packets sent   from the DUT at the full rate without losing any of them.  When using   reliable transport protocols (see alsoSection 4.3.3) to transmit   Flow Export data, the Collector MUST have sufficient resources to   guarantee non-blocking data transmission on the transport-layer   session.   During the analysis, the Flow Export data needs to be decoded and the   received Flow Records counted.   The capture buffer MUST be cleared at the beginning of each   measurement.4.5.  Sampling   Packet sampling and flow sampling is out of the scope of this   document.  This document applies to situations without packet, flow,   or export sampling.4.6.  Frame Formats   Flow monitoring itself is not dependent in any way on the media used   on the input and output ports.  Any media can be used as supported by   the DUT and the test equipment.  This applies both to data forwarding   interfaces and to the export interface (see Figure 2).   At the time of this writing, the most common transmission media and   corresponding frame formats (e.g., Ethernet, Packet over SONET) for   IPv4, IPv6, and MPLS traffic are specified within [RFC2544],   [RFC5180], and [RFC5695].   The presented frame formats MUST be recorded in the measurement   report.Novak                         Informational                    [Page 19]

RFC 6645              Flow Monitoring Benchmarking             July 20124.7.  Frame Sizes   Frame sizes of the traffic to be analyzed by the DUT are specified inSection 9 of [RFC2544] for Ethernet type interfaces (64, 128, 256,   1024, 1280, 1518 bytes) and inSection 5 of [RFC5180] for Packet over   SONET interfaces (47, 64, 128, 256, 1024, 1280, 1518, 2048, 4096   bytes).   When measuring with large frame sizes, care needs to be taken to   avoid any packet fragmentation on the DUT interfaces that could   negatively affect measured performance values.   The presented frame sizes MUST be recorded in the measurement report.4.8.  Flow Export Data Packet Sizes   The Flow monitoring performance will be affected by the packet size   that the particular implementation uses to transmit Flow Export data   to the Collector.  The used packet size MUST be part of the   measurement report and only measurements with same packet sizes   SHOULD be compared.   The DUT export interface (see Figure 2) maximum transmission unit   (MTU) SHOULD be configured to the largest available value for the   media.  The Flow Export MTU MUST be recorded in the measurement   report.4.9.  Illustrative Test Setup Examples   The examples below represent a hypothetical test setup to clarify the   use of Flow monitoring parameters and configuration, together with   traffic parameters to test Flow monitoring.  The actual benchmarking   specifications are in Sections5 and6.4.9.1.  Example 1 - Idle Timeout Flow Expiration   The traffic generator sends 1000 packets per second in 10000 defined   streams, each stream identified by a unique destination IP address.   Therefore, each stream has a packet rate of 0.1 packets per second.   The packets are sent in a round-robin fashion (stream 1 to 10000)   while incrementing the destination IP address for each sent packet.   After a packet for stream 10000 is sent, the next packet destination   IP address corresponds to stream 1's address again.   The configured Cache Size is 20000 Flow Records.  The configured   Active Timeout is 100 seconds, and the Idle Timeout is 5 seconds.Novak                         Informational                    [Page 20]

RFC 6645              Flow Monitoring Benchmarking             July 2012   Flow monitoring on the DUT uses the destination IP address as the   Flow Key.   A packet with the destination IP address equal to A is sent every 10   seconds, so the Cache entry is refreshed in the Cache every 10   seconds.  However, the Idle Timeout is 5 seconds, so the Cache   entries will expire from the Cache due to the Idle Timeout, and when   a new packet is sent with the same IP address A, it will create a new   entry in the Cache.  This behavior depends upon the design and   efficiency of the Cache ager, and incidences of multi-packet flows   observed during this test should be noted.   The measured Flow Export Rate in this case will be 1000 Flow Records   per second since every single sent packet will always create a new   Cache entry and 1000 packets per second are sent.   The expected number of Cache entries in the Cache during the whole   measurement is around 5000.  It corresponds to the Idle Timeout being   5 seconds; during those five seconds, 5000 entries are created.  This   expectation might change in real measurement setups with large Cache   Sizes and a high packet rate where the DUT's actual export rate might   be limited and lower than the Flow Expiration activity caused by the   traffic offered to the DUT.  This behavior is entirely   implementation-specific.4.9.2.  Example 2 - Active Timeout Flow Expiration   The traffic generator sends 1000 packets per second in 100 defined   streams, each stream identified by a unique destination IP address.   Each stream has a packet rate of 10 packets per second.  The packets   are sent in a round-robin fashion (stream 1 to 100) while   incrementing the destination IP address for each sent packet.  After   a packet for stream 100 is sent, the next packet destination IP   address corresponds to stream 1's address again.   The configured Cache Size is 1000 Flow Records.  The configured   Active Timeout is 100 seconds.  The Idle Timeout is 10 seconds.   Flow monitoring on the DUT uses the destination IP address as the   Flow Key.   After the first 100 packets are sent, 100 Cache entries will have   been created in the Flow monitoring Cache.  The subsequent packets   will be counted against the already created Cache entries since the   destination IP address (Flow Key) has already been seen by the DUT   (provided the Cache entries did not expire yet as described below).Novak                         Informational                    [Page 21]

RFC 6645              Flow Monitoring Benchmarking             July 2012   A packet with the destination IP address equal to A is sent every 0.1   second, so the Cache entry is refreshed in the Cache every 0.1   second, while the Idle Timeout is 10 seconds.  In this case, the   Cache entries will not expire until the Active Timeout expires, e.g.,   they will expire every 100 seconds and then the Cache entries will be   created again.   If the test measurement time is 50 seconds from the start of the   traffic generator, then the measured Flow Export Rate is 0 since   during this period nothing expired from the Cache.   If the test measurement time is 100 seconds from the start of the   traffic generator, then the measured Flow Export Rate is 1 Flow   Record per second.   If the test measurement time is 290 seconds from the start of the   traffic generator, then the measured Flow Export Rate is 2/3 of a   Flow Record per second since the Cache expired the same number of   Flows twice (100) during the 290-seconds period.5.  Flow Monitoring Throughput Measurement Methodology   Objective:      To measure the Flow monitoring performance in a manner that is      comparable between different Flow monitoring implementations.   Metric definition:      Flow Monitoring Throughput - seeSection 3.   Discussion:      Different Flow monitoring implementations might choose to handle      Flow Export from a partially empty Cache differently than in the      case of the Cache being fully occupied.  Similarly, software- and      hardware-based DUTs can handle the same situation as stated above      differently.  The purpose of the benchmark measurement in this      section is to define one measurement procedure covering all the      possible behaviors.      The only criteria is to measure as defined here until Flow Record      or packet losses are seen.  The decision whether to dive deeper      into the conditions under which the packet losses happen is left      to the tester.Novak                         Informational                    [Page 22]

RFC 6645              Flow Monitoring Benchmarking             July 20125.1.  Flow Monitoring Configuration   Cache Size      Cache Size configuration is dictated by the expected position of      the DUT in the network and by the chosen Flow Keys of the Flow      Record.  The number of unique sets of Flow Keys that the traffic      generator (sender) provides should be multiple times larger than      the Cache Size.  This ensures that the existing Cache entries are      never updated by a packet from the sender before the particular      Flow Expiration and Flow Export.  This condition is simple to      fulfill with linearly incremented Flow Keys (for example, IP      addresses or transport-layer ports) where the range of values must      be larger than the Cache Size.  When randomized traffic generation      is in use, the generator must ensure that the same Flow Keys are      not repeated within a range of randomly generated values.      The Cache Size MUST be known in order to define the measurement      circumstances properly.  Typically, the Cache Size will be found      using the "show" commands of the Flow monitoring implementation in      the actual configuration or in the product documentation from the      vendor.   Idle Timeout      Idle Timeout is set (if configurable) to the minimum possible      value on the DUT.  This ensures that the Cache entries are expired      as soon as possible and exported out of the DUT Cache.  It MUST be      known in order to define the measurement circumstances completely      and equally across implementations.   Active Timeout      Active Timeout is set (if configurable) to a value equal to or      higher than the Idle Timeout.  It MUST be known in order to define      the measurement circumstances completely and equally across      implementations.   Flow Keys Definition:      The test needs large numbers of unique Cache entries to be created      by incrementing values of one or several Flow Keys.  The number of      unique combinations of Flow Keys values SHOULD be several times      larger than the DUT Cache Size.  This makes sure that any incoming      packet will never refresh any already existing Cache entry.   The availability of Cache Size, Idle Timeout, and Active Timeout as   configuration parameters is implementation-specific.  If the Flow   monitoring implementation does not support these parameters, the test   possibilities, as specified by this document, are restricted.  SomeNovak                         Informational                    [Page 23]

RFC 6645              Flow Monitoring Benchmarking             July 2012   testing might be viable if the implementation follows the guidance   provided in the [IPFIX-CONFIG] document and is considered on a case-   by-case basis.5.2.  Traffic Configuration   Traffic Generation      The traffic generator needs to increment the Flow Keys values with      each sent packet.  This way, each packet represents one Cache      entry in the DUT Cache.      A particular Flow monitoring implementation might choose to deploy      a hashing mechanism to match incoming data packets to a certain      Flow.  In such a case, the combination of how the traffic is      constructed and the hashing might influence the DUT Flow      monitoring performance.  For example, if IP addresses are used as      Flow Keys, this means there could be a performance difference for      linearly incremented addresses (in ascending or descending order)      as opposed to IP addresses randomized in a certain range.  If      randomized IP address sequences are used, then the traffic      generator needs to be able to reproduce the randomization (e.g.,      the same set of IP addresses sent in the same order in different      test runs) in order to compare various DUTs and Flow monitoring      implementations.      If the test traffic rate is below the maximum media rate for the      particular packet size, the traffic generator MUST send the      packets in equidistant time intervals.  Traffic generators that do      not fulfill this condition MUST NOT and cannot be used for the      Flow Monitoring Throughput measurement.  An example of this      behavior is if the test traffic rate is one half of the media      rate.  The traffic generator achieves this rate by sending packets      each half of each second at the full media rate and sending      nothing for the second half of each second.  In such conditions,      it would be impossible to distinguish if the DUT failed to handle      the Flows due to the shortage of input buffers during the burst or      due to the limits in the Flow monitoring performance.   Measurement Duration      The measurement duration (e.g., how long the test traffic is sent      to the DUT) MUST be at least two-times longer than the Idle      Timeout; otherwise, no Flow Export would be seen.  The measurement      duration SHOULD guarantee that the number of Cache entries created      during the measurement exceeds the available Cache Size.Novak                         Informational                    [Page 24]

RFC 6645              Flow Monitoring Benchmarking             July 20125.3.  Cache Population   The product of the Idle Timeout and the packet rate offered to the   DUT (Cache population) during one measurement determines the total   number of Cache entries in the DUT Cache during the measurement   (while taking into account some margin for dynamic behavior during   high DUT loads when processing the Flows).   The Flow monitoring implementation might behave differently depending   on the relation of the Cache population to the available Cache Size   during the measurement.  This behavior is fully implementation-   specific and will also be influenced if the DUT architecture is   software based or hardware based.   The Cache population (if it is lower or higher than the available   Cache Size) during a particular benchmark measurement SHOULD be   noted, and mainly only measurements with the same Cache population   SHOULD be compared.5.4.  Measurement Time Interval   The measurement time interval is the time value that is used to   calculate the measured Flow Export Rate from the captured Flow Export   data.  It is obtained as specified below.RFC 2544 specifies, with the precision of the packet beginning and   ending, the time intervals to be used to measure the DUT time   characteristics.  In the case of a Flow Monitoring Throughput   measurement, the start and stop time needs to be clearly defined, but   the granularity of this definition can be limited to just marking the   start and stop time with the start and stop of the traffic generator.   This assumes that the traffic generator and DUT are collocated and   the variance in transmission delay from the generator to the DUT is   negligible as compared to the total time of traffic generation.   The measurement start time:      the time when the traffic generator is started   The measurement stop time: the time when the traffic generator is      stopped   The measurement time interval is then calculated as the difference   (stop time) - (start time) - (Idle Timeout).   This supposes that the Cache Size is large enough that the time   needed to fill it with Cache entries is longer than the Idle Timeout.   Otherwise, the time needed to fill the Cache needs to be used to   calculate the measurement time interval in place of the Idle Timeout.Novak                         Informational                    [Page 25]

RFC 6645              Flow Monitoring Benchmarking             July 2012   Instead of measuring the absolute values of the stop and start times,   it is possible to set up the traffic generator to send traffic for a   certain predefined time interval, which is then used in the above   definition instead of the difference (stop time) - (start time).   The Collector MUST stop collecting the Flow Export data at the   measurement stop time.   The Idle Timeout (or the time needed to fill the Cache) causes delay   of the Flow Export data behind the test traffic that is analyzed by   the DUT.  For example, if the traffic starts at time point X, Flow   Export will start only at the time point X + Idle Timeout (or X +   time to fill the Cache).  Since Flow Export capture needs to stop   with the traffic (because that's when the DUT stops processing the   Flows at the given rate), the time interval during which the DUT kept   exporting data is shorter by the Idle Timeout than the time interval   when the test traffic was sent from the traffic generator to the DUT.5.5.  Flow Export Rate Measurement   The Flow Export Rate needs to be measured in two consequent steps.   The purpose of the first step (point a. below) is to gain the actual   value for the rate; the second step (point b. below) needs to be done   in order to verify that no Flow Record are dropped during the   measurement:   a. In the first step, the captured Flow Export data MUST be analyzed      only for the capturing interval (measurement time interval) as      specified inSection 5.4.  During this period, the DUT is forced      to process Cache entries at the rate the packets are sent.  When      traffic generation finishes, the behavior when emptying the Cache      is completely implementation-specific; therefore, the Flow Export      data from this period cannot be used for benchmarking.   b. In the second step, all the Flow Export data from the DUT MUST be      captured in order to determine the Flow Record losses.  It needs      to be taken into account that especially when large Cache Sizes      (in order of magnitude of hundreds of thousands of entries and      higher) are in use, the Flow Export can take many multiples of      Idle Timeout to empty the Cache after the measurement.  This      behavior is completely implementation-specific.   If the Collector has the capability to redirect the Flow Export data   after the measurement time interval into a different capture buffer   (or time stamp the received Flow Export data after that), this can be   done in one step.  Otherwise, each Flow Monitoring Throughput   measurement at a certain packet rate needs to be executed twice --   once to capture the Flow Export data just for the measurement timeNovak                         Informational                    [Page 26]

RFC 6645              Flow Monitoring Benchmarking             July 2012   interval (to determine the actual Flow Export Rate) and a second time   to capture all Flow Export data in order to determine Flow Record   losses at that packet rate.   At the end of the measurement time interval, the DUT might still be   processing Cache entries that belong to the Flows expired from the   Cache before the end of the interval.  These Flow Records might   appear in an export packet sent only after the end of the measurement   interval.  This imprecision can be mitigated by use of large amounts   of Flow Records during the measurement (so that the few Flow Records   in one export packet can be ignored) or by use of timestamps exported   with the Flow Records.5.6.  The Measurement Procedure   The measurement procedure is the same as the Throughput measurement   inSection 26.1 of [RFC2544] for the traffic sending side.  The DUT   output analysis is done on the traffic generator receiving side for   the test traffic, the same way as forRFC 2544 measurements.   An additional analysis is performed using data captured by the   Collector.  The purpose of this analysis is to establish the value of   the Flow Export Rate during the current measurement step and to   verify that no Flow Records were dropped during the measurement.  The   procedure for measuring the Flow Export Rate is described inSection5.5.   The Flow Export performance can be significantly affected by the way   the Flow monitoring implementation formats the Flow Records into the   Flow Export packets.  The ordering and frequency in which Control   Information is exported and the number of Flow Records in one Flow   Export packet are of interest.  In the worst case scenario, there is   just one Flow Record in every Flow Export packet.   Flow Export data should be sanity checked during the benchmark   measurement for:   a. the number of Flow Records per packet, by simply calculating the      ratio of exported Flow Records to the number of Flow Export      packets captured during the measurement (which should be available      as a counter on the Collector capture buffer).   b. the number of Flow Records corresponding to the export of Control      Information per Flow Export packet (calculated as the ratio of the      total number of such Flow Records in the Flow Export data and the      number of Flow Export packets).Novak                         Informational                    [Page 27]

RFC 6645              Flow Monitoring Benchmarking             July 20126.RFC 2544 MeasurementsRFC 2544 measurements can be performed under two Flow monitoring   setups (see alsoSection 3.4.2).  This section details both and   specifies ways to construct the test traffic so thatRFC 2544   measurements can be performed in a controlled environment from the   Flow monitoring point of view.  A controlled Flow monitoring   environment means that the tester always knows what Flow monitoring   activity (Flow Export Rate) the traffic offered to the DUT causes.   This section is applicable mainly for the Throughput (RFC 2544,   Section 26.1) and latency (RFC 2544, Section 26.2 ) measurements.  It   could also be used to measure frame loss rate (RFC 2544, Section 26.3) and back-to-back frames (RFC 2544, Section 26.4).  Flow Export   requires DUT resources to be generated and transmitted; therefore,   the Throughput in most cases will be much lower when Flow monitoring   is enabled on the DUT than when it is not.   Objective:      ProvideRFC 2544 network device characteristics in the presence of      Flow monitoring on the DUT.RFC 2544 studies numerous      characteristics of network devices.  The DUT forwarding and time      characteristics without Flow monitoring present on the DUT can      vary significantly when Flow monitoring is deployed on the network      device.   Metric definition:      Metric as specified in [RFC2544].   The measured Throughput MUST NOT include the packet rate   corresponding to the Flow Export data, because it is not user traffic   forwarded by the DUT.  It is generated by the DUT as a result of   enabling Flow monitoring and does not contribute to the test traffic   that the DUT can handle.  Flow Export requires DUT resources to be   generated and transmitted; therefore, the Throughput in most cases   will be much lower when Flow monitoring is enabled on the DUT than   when it is not.6.1.  Flow Monitoring Configuration   Flow monitoring configuration (as detailed inSection 4.3) needs to   be applied the same way as discussed inSection 5 with the exception   of the Active Timeout configuration.   The Active Timeout SHOULD be configured to exceed several times the   measurement time interval (seeSection 5.4).  This ensures that ifNovak                         Informational                    [Page 28]

RFC 6645              Flow Monitoring Benchmarking             July 2012   measurements with two traffic components are performed (seeSection6.3.2), there is no Flow monitoring activity related to the second   traffic component.   The Flow monitoring configuration does not change in any other way   for the measurement performed in this section.  What changes and   makes the difference is the traffic configurations as specified in   the sections below.6.2.  Measurements with the Flow Monitoring Throughput Setup   To perform a measurement with Flow Monitoring Throughput setup, the   major requirement is that the traffic and Flow monitoring be   configured in such a way that each sent packet creates one entry in   the DUT Cache.  This restricts the possible setups only to the   measurement with two traffic components as specified inSection6.3.2.6.3.  Measurements with a Fixed Flow Export Rate   This section covers the measurements where theRFC 2544 metrics need   to be measured with Flow monitoring enabled, but at a certain Flow   Export Rate that is lower than the Flow Monitoring Throughput.   The tester here has both options as specified in Sections6.3.1 and   6.3.2.6.3.1.  Measurements with a Single Traffic ComponentSection 12 of [RFC2544] discusses the use of protocol source and   destination addresses for defined measurements.  To perform all theRFC 2544 type measurements with Flow monitoring enabled, the defined   Flow Keys SHOULD contain an IP source and destination address.  TheRFC 2544 type measurements with Flow monitoring enabled then can be   executed under these additional conditions:   a. the test traffic is not limited to a single, unique pair of source      and destination addresses.   b. the traffic generator defines test traffic as follows: it allows      for a parameter to send N (where N is an integer number starting      at 1 and is incremented in small steps) packets with source IP      address A and destination IP address B before changing both IP      addresses to the next value.   This test traffic definition allows execution of the Flow monitoring   measurements with a fixed Flow Export Rate while measuring the DUTRFC 2544 characteristics.  This setup is the better option since itNovak                         Informational                    [Page 29]

RFC 6645              Flow Monitoring Benchmarking             July 2012   best simulates the live network traffic scenario with Flows   containing more than just one packet.   The initial packet rate at N equal to 1 defines the Flow Export Rate   for the whole measurement procedure.  Subsequent increases of N will   not change the Flow Export Rate as the time and Cache characteristics   of the test traffic stay the same.  This setup is suitable for   measurements with Flow Export Rates below the Flow Monitoring   Throughput.6.3.2 Measurements with Two Traffic Components   The test traffic setup described inSection 6.3.1 might be difficult   to achieve with commercial traffic generators or if the granularity   of the traffic rates as defined by the initial packet rate at N equal   to 1 are unsuitable for the required measurement.  An alternative   mechanism is to define two traffic components in the test traffic:   one to populate Flow monitoring Cache and the second to execute theRFC 2544 measurements.   a. Flow monitoring test traffic component -- the exact traffic      definition as specified inSection 5.2.   b.RFC 2544 Test Traffic Component -- test traffic as specified byRFC 2544 MUST create just one entry in the DUT Cache.  In the      particular setup discussed here, this would mean a traffic stream      with just one pair of unique source and destination IP addresses      (but could be avoided if Flow Keys were, for example, UDP/TCP      source and destination ports and Flow Keys did not contain the      addresses).   The Flow monitoring traffic component will exercise the DUT in terms   of Flow activity, while the second traffic component will measure theRFC 2544 characteristics.   The measured Throughput is the sum of the packet rates of both   traffic components.  The definition of otherRFC 1242 metrics remains   unchanged.7.  Flow Monitoring Accuracy   The pure Flow Monitoring Throughput measurement described inSection5 provides the capability to verify the Flow monitoring accuracy in   terms of the exported Flow Record data.  Since every Cache entry   created in the Cache is populated by just one packet, the full set of   captured data on the Collector can be parsed (e.g., providing the   values of all Flow Keys and other Flow Record fields, not only the   overall Flow Record count in the exported data), and each set ofNovak                         Informational                    [Page 30]

RFC 6645              Flow Monitoring Benchmarking             July 2012   parameters from each Flow Record can be checked against the   parameters as configured on the traffic generator and set in packets   sent to the DUT.  The exported Flow Record is considered accurate if:   a. all the Flow Record fields are present in each exported Flow      Record.   b. all the Flow Record fields' values match the value ranges set by      the traffic generator (for example, an IP address falls within the      range of the IP address increments on the traffic generator).   c. all the possible Flow Record field values as defined at the      traffic generator have been found in the captured export data on      the Collector.  This check needs to be offset against detected      packet losses at the DUT during the measurement.   For a DUT with packet forwarding, the Flow monitoring accuracy also   involves data checks on the received traffic, as already discussed inSection 4.8.  Evaluating Flow Monitoring Applicability   The measurement results, as discussed in this document and obtained   for certain DUTs, allow for a preliminary analysis of a Flow   monitoring deployment based on the traffic analysis data from the   providers' network.  An example of such traffic analysis in the   Internet is provided by [CAIDA]; the way it can be used is discussed   below.  The data needed to estimate if a certain network device can   manage the particular amount of live traffic with Flow monitoring   enabled is:   Average packet size:            350 bytes   Number of packets per IP flow:  20   Expected data rate on the network device: 1 Gbit/s   The average number of Flows created per second in the network device   is needed and is determined as follows:                       Expected packet rate   Flows per second =  --------------------                       Packet per flow   When using the above example values, the network device is required   to process 18000 Flows per second.  By executing the benchmarking as   specified in this document, a platform capable of this processing can   be determined for the deployment in that particular part of the user   network.Novak                         Informational                    [Page 31]

RFC 6645              Flow Monitoring Benchmarking             July 2012   Keep in mind that the above is a very rough and averaged Flow   activity estimate, which cannot account for traffic anomalies; for   example, a large number of DNS request packets that are typically   small packets coming from many different sources and represent mostly   just one packet per Flow.9.  Acknowledgements   This work was performed thanks to the patience and support of Cisco   Systems NetFlow development team, namely Paul Aitken, Paul Atkins,   and Andrew Johnson.  Thanks to Benoit Claise for numerous detailed   reviews and presentations of the document, and to Aamer Akhter for   initiating this work.  A special acknowledgment to the entire BMWG   working group, especially to the chair, Al Morton, for the support   and work on this document and Paul Aitken for a very detailed   technical review.10.  Security Considerations   Documents of this type do not directly affect the security of the   Internet or corporate networks as long as benchmarking is not   performed on devices or systems connected to operating networks.   Benchmarking activities, as described in this memo, are limited to   technology characterization using controlled stimuli in a laboratory   environment, with dedicated address space and the constraints   specified in sections above.   The benchmarking network topology will be an independent test setup   and MUST NOT be connected to devices that may forward the test   traffic into a production network, or misroute traffic to the test   management network.   Further, benchmarking is performed on a "black-box" basis, relying   solely on measurements observable external to the DUT.   Special capabilities SHOULD NOT exist in the DUT specifically for   benchmarking purposes.  Any implications for network security arising   from the DUT SHOULD be identical in the lab and in production   networks.Novak                         Informational                    [Page 32]

RFC 6645              Flow Monitoring Benchmarking             July 201211.  References11.1.  Normative References   [RFC2119]   Bradner, S., "Key words for use in RFCs to Indicate               Requirement Levels",BCP 14,RFC 2119, March 1997.   [RFC2544]   Bradner, S. and J. McQuaid, "Benchmarking Methodology for               Network Interconnect Devices",RFC 2544, March 1999.11.2.  Informative References   [RFC1242]   Bradner, S., "Benchmarking Terminology for Network               Interconnection Devices",RFC 1242, July 1991.   [RFC2285]   Mandeville, R., "Benchmarking Terminology for LAN               Switching Devices",RFC 2285, February 1998.   [RFC3031]   Rosen, E., Viswanathan, A., and R. Callon, "Multiprotocol               Label Switching Architecture",RFC 3031, January 2001.   [RFC3917]   Quittek, J., Zseby, T., Claise, B., and S. Zander,               "Requirements for IP Flow Information Export (IPFIX)",RFC 3917, October 2004.   [RFC3954]   Claise, B., Ed., "Cisco Systems NetFlow Services Export               Version 9",RFC 3954, October 2004.   [RFC5101]   Claise, B., Ed., "Specification of the IP Flow               Information Export (IPFIX) Protocol for the Exchange of               IP Traffic Flow Information",RFC 5101, January 2008.   [RFC5180]   Popoviciu, C., Hamza, A., Van de Velde, G., and D.               Dugatkin, "IPv6 Benchmarking Methodology for Network               Interconnect Devices",RFC 5180, May 2008.   [RFC5470]   Sadasivan, G., Brownlee, N., Claise, B., and J. Quittek,               "Architecture for IP Flow Information Export",RFC 5470,               March 2009.   [RFC5695]   Akhter, A., Asati, R., and C. Pignataro, "MPLS Forwarding               Benchmarking Methodology for IP Flows",RFC 5695,               November 2009.   [CAIDA]     Claffy, K., "The nature of the beast: recent traffic               measurements from an Internet backbone",http://www.caida.org/publications/papers/1998/Inet98/Inet98.htmlNovak                         Informational                    [Page 33]

RFC 6645              Flow Monitoring Benchmarking             July 2012   [IPFIX-CONFIG]               Muenz, G., Muenchen, TU, Claise, B., and P. Aitken,               "Configuration Data Model for IPFIX and PSAMP", Work in               Progress, July 2011.   [PSAMP-MIB] Dietz, T., Claise, B., and J. Quittek, "Definitions of               Managed Objects for Packet Sampling", Work in Progress,               October 2011.   [IPFIX-MIB] Dietz, T., Kobayashi, A., Claise, B., and G. Muenz,               "Definitions of Managed Objects for IP Flow Information               Export", Work in Progress, March 2012.Novak                         Informational                    [Page 34]

RFC 6645              Flow Monitoring Benchmarking             July 2012Appendix A.  (Informative) Recommended Report FormatParameter                           Units----------------------------------- ------------------------------------Test Case                           test case name (Sections5 and6)Test Topology                       Figure 2, otherTraffic Type                        IPv4, IPv6, MPLS, otherTest Results  Flow Monitoring Throughput        Flow Records per second or Not                                    Applicable  Flow Export Rate                  Flow Records per second or Not                                    Applicable  Control Information Export Rate   Flow Records per second  Throughput                        packets per second  (OtherRFC 1242 Metrics)          (as appropriate)General Parameters  DUT Interface Type                Ethernet, POS, ATM, other  DUT Interface Bandwidth           MegaBits per secondTraffic Specifications  Number of Traffic Components      (see Sections6.3.1 and6.3.2)  For each traffic component:  Packet Size                       bytes  Traffic Packet Rate               packets per second  Traffic Bit Rate                  MegaBits per second  Number of Packets Sent            number of entries  Incremented Packet Header Fields  list of fields  Number of Unique Header Values    number of entries  Number of Packets per Flow        number of entries  Traffic Generation                linearly incremented or                                    randomizedFlow monitoring Specifications  Direction                         ingress, egress, both  Observation Points                DUT interface names  Cache Size                        number of entries  Active Timeout                    seconds  Idle Timeout                      seconds  Flow Keys                         list of fields  Flow Record Fields                total number of fields  Number of Flows Created           number of entries  Flow Export Transport Protocol    UDP, TCP, SCTP, other  Flow Export Protocol              IPFIX, NetFlow, other  Flow Export data packet size      bytes  Flow Export MTU                   bytesNovak                         Informational                    [Page 35]

RFC 6645              Flow Monitoring Benchmarking             July 2012Parameter                           Units (continued)----------------------------------- ------------------------------------MPLS Specifications                 (for traffic type MPLS only)  Tested Label Operation            imposition, swap, dispositionThe format of the report as documented in this appendix is informative,but the entries in the contents of it are required as specified in thecorresponding sections of this document.Many of the configuration parameters required by the measurement reportcan be retrieved from the [IPFIX-MIB] and [PSAMP-MIB] MIB modules, andfrom the [IPFIX-CONFIG] YANG module or other general MIBs.  Therefore,querying those modules from the DUT would be beneficial: first of all,to help in populating the required entries of the measurement report,and also to document all the other configuration parameters from theDUT.Appendix B.  (Informative) Miscellaneous Tests   This section lists tests that could be useful to asses a proper Flow   monitoring operation under various operational or stress conditions.   These tests are not deemed suitable for any benchmarking for various   reasons.B.1.  DUT Under Traffic Load   The Flow Monitoring Throughput should be measured under different   levels of static traffic load through the DUT.  This can be achieved   only by using two traffic components as discussed inSection 6.3.2.   One traffic component exercises the Flow Monitoring Plane.  The   second traffic component loads only the Forwarding Plane without   affecting Flow monitoring (i.e., it creates just a certain amount of   permanent Cache entries).   The variance in Flow Monitoring Throughput as a function of the   traffic load should be noted for comparison purposes between two DUTs   of similar architecture and capability.B.2.  In-Band Flow Export   The test topology inSection 4.1 mandates the use of a separate Flow   Export interface to avoid the Flow Export data generated by the DUT   to mix with the test traffic from the traffic generator.  This is   necessary in order to create clear and reproducible test conditions   for the benchmark measurement.   The real network deployment of Flow monitoring might not allow for   such a luxury -- for example, on a very geographically large network.Novak                         Informational                    [Page 36]

RFC 6645              Flow Monitoring Benchmarking             July 2012   In such a case, the Flow Export will use an ordinary traffic   forwarding interface, e.g., in-band Flow Export.   The Flow monitoring operation should be verified with in-band Flow   Export configuration while following these test steps:   a. Perform the benchmark test as specified inSection 5.  One of the      results will be how much bandwidth Flow Export used on the      dedicated Flow Export interface.   b. Change Flow Export configuration to use the test interface.   c. Repeat the benchmark test while the receiver filters out the Flow      Export data from analysis.   The expected result is that the Throughput achieved in step a. is   same as the Throughput achieved in step c. provided that the   bandwidth of the output DUT interface is not the bottleneck (in other   words, it must have enough capacity to forward both test and Flow   Export traffic).B.3.  Variable Packet Size   The Flow monitoring measurements specified in this document would be   interesting to repeat with variable packet sizes within one   particular test (e.g., test traffic containing mixed packet sizes).   The packet forwarding tests specified mainly in [RFC2544] do not   recommend performing such tests.  Flow monitoring is not dependent on   packet sizes, so such a test could be performed during the Flow   Monitoring Throughput measurement, and verification of its value does   not depend on the offered traffic packet sizes.  The tests must be   carefully designed in order to avoid measurement errors due to the   physical bandwidth limitations and changes of the base forwarding   performance with packet size.B.4.  Bursty TrafficRFC 2544, Section 21 discusses and defines the use of bursty traffic.   It can be used for Flow monitoring testing to gauge some short-term   overload DUT capabilities in terms of Flow monitoring.  The test   benchmark here would not be the Flow Export Rate the DUT can sustain,   but the absolute number of Flow Records the DUT can process without   dropping any single Flow Record.  The traffic setup to be used for   this test is as follows:   a. each sent packet creates a new Cache entry.   b. the packet rate is set to the maximum transmission speed of the      DUT interface used for the test.Novak                         Informational                    [Page 37]

RFC 6645              Flow Monitoring Benchmarking             July 2012B.5.  Various Flow Monitoring Configurations   This section translates the terminology used in the IPFIX documents   ([RFC5470], [RFC5101], and others) into the terminology used in this   document.  Section B.5.2 proposes another measurement that is   impossible to verify in a black box test manner.B.5.1.  Throughput without the Metering Process   If the Metering Process is not defined on the DUT it means no Flow   monitoring Cache exists and no Flow analysis occurs.  The performance   measurement of the DUT in such a case is just pure [RFC2544]   measurement.B.5.2.  Throughput with the Metering Process   If only the Metering Process is enabled, Flow analysis on the DUT is   enabled and operational but no Flow Export happens.  The performance   measurement of a DUT in such a configuration represents a useful test   of the DUT's capabilities (this corresponds to the case when the   network operator uses Flow monitoring, for example, for manual   detection of denial-of-service attacks, and does not wish to use Flow   Export).   The performance testing on this DUT can be performed as discussed in   this document, but it is not possible to verify the operation and   results without interrogating the DUT.B.5.3.  Throughput with the Metering and Exporting Processes   This test represents the performance testing as discussed inSection6.B.6.  Tests With Bidirectional Traffic   Bidirectional traffic is not part of the normative benchmarking tests   based on discussion with and recommendation of the Benchmarking   working group.  The experienced participants stated that this kind of   traffic did not provide reproducible results.   The test topology in Figure 2 can be expanded to verify Flow   monitoring functionality with bidirectional traffic using the   interfaces in full duplex mode, e.g., sending and receiving   simultaneously on each of them.   The same rules should be applied for Flow creation in the DUT Cache   (as per Sections4.1 and4.3.1) -- traffic passing through each   Observation Point should always create a new Cache entry in theNovak                         Informational                    [Page 38]

RFC 6645              Flow Monitoring Benchmarking             July 2012   Cache, e.g., the same traffic should not be just looped back on the   receiving interfaces to create the bidirectional traffic flow.B.7.  Instantaneous Flow Export Rate   Additional useful information when analyzing the Flow Export data is   the time distribution of the instantaneous Flow Export Rate.  It can   be derived during the measurements in two ways:   a. The Collector might provide the capability to decode Flow Export      during capturing and at the same time count the Flow Records and      provide the instantaneous (or simply, an average over shorter time      interval than specified inSection 5.4) Flow Export Rate.   b. The Flow Export protocol (like IPFIX [RFC5101]) can provide time      stamps in the Flow Export packets that would allow time-based      analysis and calculate the Flow Export Rate as an average over      much shorter time interval than specified inSection 5.4.   The accuracy and shortest time average will always be limited by the   precision of the time stamps (1 second for IPFIX) or by the   capabilities of the DUT and the Collector.Author's Address   Jan Novak (editor)   Cisco Systems   Edinburgh   United Kingdom   EMail: janovak@cisco.comNovak                         Informational                    [Page 39]