Movatterモバイル変換


[0]ホーム

URL:


[RFC Home] [TEXT|PDF|HTML] [Tracker] [IPR] [Errata] [Info page]

INFORMATIONAL
Errata Exist
Internet Engineering Task Force (IETF)                       C. PetrucciRequest for Comments: 6109                                       DigitPACategory: Informational                                        F. GennaiISSN: 2070-1721                                                A. Shahin                                                                ISTI-CNR                                                          A. Vinciarelli                                                              April 2011La Posta Elettronica Certificata - Italian Certified Electronic MailAbstract   Since 1997, the Italian laws have recognized electronic delivery   systems as legally usable.  In 2005, after two years of technical   tests, the characteristics of an official electronic delivery   service, named certified electronic mail (in Italian "Posta   Elettronica Certificata") were defined, giving the system legal   standing.   The design of the entire system was carried out by the National   Center for Informatics in the Public Administration of Italy   (DigitPA), followed by efforts for the implementation and testing of   the service.  The DigitPA has given the Italian National Research   Council (CNR), and in particular the Institute of Information Science   and Technologies at the CNR (ISTI), the task of running tests on   providers of the service to guarantee the correct implementation and   interoperability.  This document describes the certified email system   adopted in Italy.  It represents the system as it is at the moment of   writing, following the technical regulations that were written based   upon the Italian Law DPR.  November 2, 2005.Status of This Memo   This document is not an Internet Standards Track specification; it is   published for informational purposes.   This document is a product of the Internet Engineering Task Force   (IETF).  It has been approved for publication by the Internet   Engineering Steering Group (IESG).  Not all documents approved by the   IESG are a candidate for any level of Internet Standard; seeSection2 of RFC 5741.   Information about the current status of this document, any errata,   and how to provide feedback on it may be obtained athttp://www.rfc-editor.org/info/rfc6109.Petrucci, et al.              Informational                     [Page 1]

RFC 6109                Certified Electronic Mail             April 2011Copyright Notice   Copyright (c) 2010 IETF Trust and the persons identified as the   document authors.  All rights reserved.   This document is subject toBCP 78 and the IETF Trust's Legal   Provisions Relating to IETF Documents   (http://trustee.ietf.org/license-info) in effect on the date of   publication of this document.  Please review these documents   carefully, as they describe your rights and restrictions with respect   to this document.  Code Components extracted from this document must   include Simplified BSD License text as described in Section 4.e of   the Trust Legal Provisions and are provided without warranty as   described in the Simplified BSD License.Petrucci, et al.              Informational                     [Page 2]

RFC 6109                Certified Electronic Mail             April 2011Table of Contents1. Introduction ....................................................51.1. Scope ......................................................51.2. Notational Conventions .....................................61.2.1. Requirement Conventions .............................61.2.2. Acronyms ............................................61.2.3. Terminology and Definitions .........................72. PEC Model .......................................................82.1. System-Generated Messages ..................................82.1.1. Message Types ......................................102.2. Basic Structure ...........................................122.2.1. Access Point .......................................122.2.2. Incoming Point .....................................142.2.3. Delivery Point .....................................162.2.4. Storage ............................................172.2.5. Provider Service Mailbox ...........................172.2.6. Provider Service Email Address .....................172.3. Log .......................................................173. Message Processing .............................................183.1. Access Point ..............................................183.1.1. Formal Checks on Messages ..........................18           3.1.2. Non-Acceptance PEC Notification Due to                  Formal Exceptions ..................................19           3.1.3. Non-Acceptance PEC Notification Due to                  Virus Detection ....................................203.1.4. Server-User Acceptance PEC Notification ............203.1.5. PEC Transport Envelope .............................213.1.6. Timeout Delivery Error PEC Notification ............233.2. Incoming Point ............................................243.2.1. Server-Server Acceptance PEC Notification ..........243.2.2. PEC Anomaly Envelope ...............................253.2.3. Virus Detection PEC Notification ...................273.2.4. Virus-Induced Delivery Error PEC notification ......283.3. Delivery Point ............................................293.3.1. Checks on Incoming Messages ........................293.3.2. Delivery PEC Notification ..........................293.3.3. Non-Delivery PEC Notification ......................343.4. Sender and Receiver Belonging to the Same Domain ..........343.5. Example: Complete Transaction between Two PEC Domains .....344. Formats ........................................................354.1. Temporal Reference ........................................354.2. User Date/Time ............................................364.3. Format of a PEC Message Body ..............................364.3.1. User Readable Text .................................374.3.2. Original Message ...................................374.3.3. Certification Data .................................374.4. Certification Data Scheme .................................37Petrucci, et al.              Informational                     [Page 3]

RFC 6109                Certified Electronic Mail             April 20114.5. PEC Providers Directory Scheme ............................394.5.1. providerCertificateHash Attribute ..................414.5.2. providerCertificate Attribute ......................414.5.3. providerName Attribute .............................414.5.4. mailReceipt Attribute ..............................424.5.5. managedDomains Attribute ...........................424.5.6. LDIFLocationURL Attribute ..........................434.5.7. providerUnit Attribute .............................434.5.8. LDIFLocationURLObject Object Class .................444.5.9. Provider Object Class ..............................444.5.10. LDIF File Example .................................445. Security-Related Aspects .......................................485.1. Digital Signature .........................................485.2. Authentication ............................................485.3. Secure Interaction ........................................495.4. Virus .....................................................495.5. S/MIME Certificate ........................................495.5.1. Provider-Related Information (Subject) .............505.5.2. Certificate Extensions .............................505.5.3. Example ............................................515.6. PEC Providers Directory ...................................556. PEC System Client Technical and Functional Prerequisites .......557. Security Considerations ........................................558. IANA Considerations ............................................568.1. Registration of PEC Message Header Fields .................568.1.1. Header Field: X-Riferimento-Message-ID: ............568.1.2. Header Field: X-Ricevuta: ..........................568.1.3. Header Field: X-VerificaSicurezza: .................578.1.4. Header Field: X-Trasporto: .........................578.1.5. Header Field: X-TipoRicevuta: ......................578.1.6. Header Field: X-Mittente: ..........................588.2. Registration of LDAP Object Identifier Descriptors ........58           8.2.1. Registration of Object Classes and                  Attribute Types ....................................589. References .....................................................599.1. Normative References ......................................599.2. Informative References ....................................6110. Acknowledgments ...............................................62Appendix A. Italian Fields and Values in English ..................63Petrucci, et al.              Informational                     [Page 4]

RFC 6109                Certified Electronic Mail             April 20111.  Introduction   Since 1997, the Italian laws have recognized electronic delivery   systems as legally usable.  In 2005, after two years of technical   tests, the characteristics of an official electronic delivery   service, named certified electronic mail (in Italian Posta   Elettronica Certificata, from now on "PEC") were defined, giving the   system legal standing.   This document represents the English version of the Italian   specifications   (http://www.digitpa.gov.it/sites/default/files/normativa/Pec_regole_tecniche_DM_2-nov-2005.pdf); the Italian version is the   normative PEC reference.   IETF review did not result in community consensus.  Since this   specification describes existing deployment and implementation, the   issues identified by the IETF community have not been addressed in   this document.  However, these issues would need to be addressed   before a successor to this document could be published.  At a   minimum, the successor document would need to include:   * A clear statement of the requirements/goals that need to be      satisfied by the protocol;   * A comprehensive diagram and description of the overall message flow      and delivery sequence required to achieve the requirements;   * Alignment with traditional terminology for IETF email and security   * A review of prior art; and   * A replacement of the unregistered LDAP DN name space used in this      specification, which may lead to conflict with other registered or      unregistered names, with a registered name space.1.1.  Scope   To ensure secure transactions over the Internet, cryptography can be   associated with electronic messages in order to provide some   guarantee on sender identity, message integrity, confidentiality, and   non-repudiation of origin.  Many end-to-end techniques exist to   accomplish such goals, and some offer a high level of security.  The   downside of end-to-end cryptography is the need for an extensive   penetration of technology in society, because it is essential for   every user to have asymmetric keys and certificates signed by a   Certification Authority.  Along with that, users would need to have   an adequate amount of knowledge regarding the use of such technology.Petrucci, et al.              Informational                     [Page 5]

RFC 6109                Certified Electronic Mail             April 2011   PEC, on the other hand, uses applications running on servers to   digitally sign messages, thus avoiding the complexity end-to-end   systems bring about.  By doing so, the user need only have an   ordinary mail client with which to interact.  The downside is that   the level of security drops, since the protection does not cover the   entire transaction.  Nonetheless, application is simpler and does not   require specific user skills, making it easily more widespread among   users.   This document describes PEC's technical aspects and features.  It   presents the details of the protocol and the messages that are sent   between service providers, introducing the system adopted by the   Italian government for the exchange of certified emails.1.2.  Notational Conventions1.2.1.  Requirement Conventions   The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",   "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this   document are to be interpreted as described in [REQ].1.2.2.  Acronyms      CMS:      Cryptographic Message Syntax      CNIPA:    Italian National Agency for Digital Administration                (Centro Nazionale per l'Informatica nella Pubblica                Amministrazione)      CNR:      Italian National Research Council (Consiglio Nazionale                delle Ricerche)      CRL:      Certificate Revocation List      CRL DP:   Certificate Revocation List Distribution Point      DNS:      Domain Name Service      DTD:      Document Type Definition      FQDN:     Fully Qualified Domain Name      ISTI:     The Institute of Information Science and Technologies                at the CNR (Istituto di Scienza e Tecnologie                dell'Informazione "A.Faedo")      LDAP:     Lightweight Directory Access Protocol      LDIF:     LDAP Data Interchange Format      MIME:     Multipurpose Internet Mail Extensions      PEC:      Certified Electronic Mail (Posta Elettronica                Certificata)      S/MIME:   Secure/MIME      SMTP:     Simple Mail Transfer Protocol      TLS:      Transport Layer Security      XML:      eXtensible Markup LanguagePetrucci, et al.              Informational                     [Page 6]

RFC 6109                Certified Electronic Mail             April 20111.2.3.  Terminology and Definitions   Certification data: A set of data certified by the sender's PEC   provider that describes the original message.  It includes the date   and time of dispatch, sender email address, recipient(s) email   address(es), subject, and message identifier.   Certified electronic mail: A service based on electronic mail, as   defined by the [EMAIL] and [SMTP] standards and extensions, which   permits the transmission of documents produced with informatics   tools.   DigitPA: Ex-CNIPA.   Holder: The person or organization to whom a PEC mailbox is assigned.   Message sent: A PEC message is considered sent when the sender's PEC   provider, after several checks, accepts the email and returns a   server-user acceptance PEC notification to the sender.   Message received: A PEC message is considered received when it is   stored in the receiver's mailbox, after which the receiver PEC   provider returns a delivery PEC notification to the sender.   Msgid: Is the message identifier generated by the email client, as   defined in [EMAIL], before the message is submitted to the PEC   system.   Ordinary mail: Non-PEC email messages.   Original message: Is the user-generated message before its arrival to   the sender Access Point.  The original message is delivered to the   recipient inside a PEC transport envelope.   PEC domain: Corresponds to a DNS domain dedicated to the holders'   mailboxes.   PEC mailbox: An electronic mailbox for which delivery PEC   notifications are issued upon reception of PEC messages.  Such a   mailbox can be defined exclusively within a PEC domain.   PEC msgid: Is a unique identifier generated by the PEC system, which   will substitute the msgid.Petrucci, et al.              Informational                     [Page 7]

RFC 6109                Certified Electronic Mail             April 2011   PEC provider: The entity that handles one or more PEC domains with   their relative points of Access, Reception, and Delivery.  It is the   holder of the key that is used for signing PEC notifications and   envelopes, and it interacts with other PEC providers for   interoperability with other holders.   PEC provider's key: Is a key released by DigitPA to every PEC   provider.  It is used to sign PEC notifications and envelopes and to   authorize access to the PEC providers directory.   PEC providers directory: Is an LDAP server positioned in an area   reachable by all PEC service providers.  It constitutes the technical   structure related to the public list of PEC service providers and   contains the list of PEC domains and service providers with relevant   certificates.   Service mailbox: A mailbox for the sole use of the provider,   dedicated for the reception of server-server acceptance and virus   detection PEC notifications.   Time stamp: Digital evidence with which a temporal reference, that   can't be repudiated, is attributed to one or more documents.2.  PEC Model2.1.  System-Generated Messages   The PEC system generates messages in MIME format composed of a   descriptive textual part and other [MIME1] parts, the number and   content of which varies according to the type of message generated.   A system-generated message falls into one of the following   categories:   o  Notifications;   o  Envelopes.   The message is inserted in an S/MIME v3 structure in CMS format and   signed with the PEC provider's private key.  The X.509v3 certificate   associated with the key MUST be included in the aforementioned   structure.  The S/MIME format used to sign system-generated messages   is the "multipart/signed" format (.p7s), as described insection3.4.3 of [SMIMEV3].   To guarantee the verifiability of signatures on as many mail clients   as possible, X.509v3 certificates used by certified email systems   MUST abide by the profile found insection 6.5.Petrucci, et al.              Informational                     [Page 8]

RFC 6109                Certified Electronic Mail             April 2011   In order for the receiving mail client to verify the signature, the   sender address MUST coincide with the one indicated within the   X.509v3 certificate.  For this mechanism, PEC transport envelopes   MUST indicate in the "From:" field a single author's address which is   different from the one contained in the original message.  To allow   for better message usability by the receiving user, the author's mail   address in the original message is inserted as a "display name".  For   example, a "From:" field such as:         From: "John Smith" <john.smith@domain.example.com>   would result in the following "From:" value in the respective PEC   transport envelope:         From: "On behalf of: john.smith@domain.example.com"                                  <certified-mail@provider.example.com>   Both "From:" and "Sender:" fields MUST contain the same value.  In   order for replies to be correctly sent back to the proper   destination, the "Reply-To:" field in the PEC transport envelope MUST   contain the same unaltered value of the original message's   "Reply-To:" field.  When it is not explicitly specified in the   original message, the system that generates the PEC transport   envelope creates it by extracting the information from the "From:"   field in the original message.   When PEC notifications are sent, the system MUST use the original   message sender's address as the destination address, as is specified   in the reverse path data of the SMTP protocol.  PEC notifications   MUST be sent to the sender's PEC mailbox without taking into account   the "Reply-To:" field, which might be present in the original   message's header.   All system-generated PEC messages are identifiable for having a   specific header defined in PEC according to the type of message   generated.   To determine the certification data, the elements used for the actual   routing of the message are employed.  In SMTP dialog phases, the   reverse path and forward path data ("MAIL FROM" and "RCPT TO"   commands) are thus considered certification data of both the sender   and the recipients, respectively.  Addressing data present in the   message body ("To:" and "Cc:" fields) are used solely in order to   discriminate between primary and carbon copy recipients when   necessary; addressing data present in the "Bcc:" field MUST be   considered invalid by the system.Petrucci, et al.              Informational                     [Page 9]

RFC 6109                Certified Electronic Mail             April 20112.1.1.  Message Types   All system-generated messages inherit their header fields and values   from the original message, with extra fields added according to the   type of message generated.2.1.1.1.  PEC Notifications   They have the purpose of informing the sending user and interacting   providers of the progress the message is making within the PEC   network.2.1.1.1.1.  Success PEC Notifications   These notifications indicate an acknowledgment on the provider's side   for the reception or handling of a PEC message.  More specifically,   it can indicate one of three situations: server-user acceptance,   server-server acceptance, or delivery.   Added header fields are:   o  X-Ricevuta:   o  X-Riferimento-Message-ID:   The field "X-Ricevuta:" indicates the type of PEC notification   contained in the message, whereas "X-Riferimento-Message-ID:"   contains the message identifier generated by the mail client (msgid).   Body contents differ according to notification type.  This is   described more thoroughly insection 3.   o  A server-user acceptance PEC notification informs the user that      his provider has accepted the message and will be taking care of      passing it on to the provider(s) of the addressee(s).   o  A server-server acceptance PEC notification is an inter-provider      communication only, it MUST NOT be sent to the users.  With this      notification, the receiving provider simply informs the sending      one that it has received a PEC message, and will take the      responsibility of forwarding it to the addressee(s).  From then      on, the sender provider is no longer held responsible as to the      whereabouts of the message, but is limited to notifying its user      of the success or failure of delivery.   o  Delivery PEC notifications take place as the final communication      of a transaction, indicating overall success in handing the      message over to the addressee(s).Petrucci, et al.              Informational                    [Page 10]

RFC 6109                Certified Electronic Mail             April 20112.1.1.1.2.  Delay PEC Notifications   Delay PEC notifications are sent out 12 hours after a message has   been dispatched from the sending provider, and no server-server   acceptance or delivery PEC notification has been received.  These   have the sole purpose of notifying the user of the delay.   If another 12 hours go by without any sign of a server-server   acceptance or delivery PEC notification (amounting to a 24-hour   delay), another delay PEC notification is dispatched to the user   informing him of the possible delivery failure.  The provider will   not keep track of the delay any further.2.1.1.1.3.  Failure PEC Notifications   They are sent when there is some error in transmission or reception.   More specifically, a failure PEC notification can indicate either a   formal-exception error or a virus detection.   Added header fields are:   o  X-Ricevuta:   o  X-Riferimento-Message-ID:   o  X-VerificaSicurezza: [optional]   "X-Ricevuta:" and "X-Riferimento-Message-ID:" have the same role as   indicated insection 2.1.1.1.1 (Success Notifications).   "X-VerificaSicurezza:" (security verification) is an optional header   field, used for virus-related PEC notifications.   Body contents differ according to notification type.  This is   described more thoroughly insection 3.2.1.1.2.  PEC Envelopes   Messages entering the PEC network are inserted within specific PEC   messages, called envelopes, before they are allowed to circulate   further within the network.  These envelopes MUST inherit the   following header fields, along with their unmodified values, from the   message itself:   o  Received:   o  To:   o  Cc:Petrucci, et al.              Informational                    [Page 11]

RFC 6109                Certified Electronic Mail             April 2011   o  Return-Path:   o  Reply-To: (if present)   Depending on the type of message requesting admission into the PEC   network, it will be inserted in either a PEC transport envelope or a   PEC anomaly envelope.  Distinction will be possible through the   addition of the "X-Trasporto:" header field.2.2.  Basic Structure                +-------------+               +------------+                |    +--+     |               |            |                |    |AP|     |      PEC      |            |      +----+    |    +--+     |   messages &  | +---+ +--+ |    +----+      |user|<-->|             |<------------->| |InP| |DP| |<-->|user|      +----+    | +--+  +---+ | notifications | +---+ +--+ |    +----+                | |DP|  |InP| |               |            |                | +--+  +---+ |               |            |                +-------------+               +------------+                     PEC                            PEC                    sender                        receiver                   provider                       provider      where:      AP = Access Point      DP = Delivery Point      InP = Incoming Point2.2.1.  Access Point   This is what the user client at the sender side interacts with,   giving the user access to PEC services set up by the provider.   Such access MUST be preceded by user authentication on the system   (seesection 5.2).  The Access Point receives the original messages   its user wishes to send, runs some formal checks, and acts according   to the outcome:   o  if the message passes all checks, the Access Point generates a      server-user acceptance PEC notification and inserts the original      message inside a PEC transport envelope;   o  if a formal exception is detected, the Access Point refuses the      message and emits the relevant non-acceptance PEC notification      (seesection 3.1.1);Petrucci, et al.              Informational                    [Page 12]

RFC 6109                Certified Electronic Mail             April 2011   o  if a virus is detected, the Access Point generates a non-      acceptance PEC notification and inserts the original message as is      in the provider's special store.   Generation of the server-user acceptance notification indicates to   the user that the message was accepted by the system, certifying also   the date and time of the event.  The notification MUST contain user-   readable text, and an XML part containing the certification data.   The notification MAY also contain other attachments for extra   features offered by the provider.   Using the data available in the PEC providers directory (seesection4.5), the Access Point runs checks on every recipient in the "To:"   and "Cc:" fields present in the original message to verify whether   they belong to the PEC infrastructure or to non-PEC domains.  Such   checks are done by verifying the existence, through a case-   insensitive search, of the recipients' domains in the   "managedDomains" attribute found within the PEC providers directory.   Therefore, the server-user acceptance PEC notification (and relevant   certification data) relates to, for each address, the typology of its   domain; PEC or non-PEC.   The message identifier (PEC msgid) of accepted original messages   within the PEC infrastructure MUST be unambiguous in order to consent   correct tracking of messages and relative PEC notifications.  The   format of such an identifier is:        [alphanumeric string]@[provider mail domain]   or:        [alphanumeric string]@[FQDN mail server]   Therefore, both the original message and the corresponding PEC   transport envelope MUST contain the following header field:        Message-ID: <[unique identifier]>   When an email client that is interacting with the Access Point has   already inserted a message identifier (msgid) in the original   message, that msgid SHALL be substituted by a PEC msgid.  In order to   allow the sender to link the message sent with the relative PEC   notifications, the msgid MUST be inserted in the original message as   well as the relative PEC notifications and transport envelope.  If   present, the msgid is REQUIRED in the original message's header by   adding the following header field:        X-Riferimento-Message-ID: <[msgid]>Petrucci, et al.              Informational                    [Page 13]

RFC 6109                Certified Electronic Mail             April 2011   which will also be inserted in the PEC transport envelope and   notifications, and related in the certification data (seesection4.4).2.2.2.  Incoming Point   This point permits the exchange of PEC messages and notifications   between PEC providers.  It is also the point through which ordinary   mail messages can be inserted within the system of certified mail.   The exchange of messages between providers takes place through SMTP-   based transactions, as defined in [SMTP].  If SMTP communication   errors occur, they MAY be handled using the standard error   notification mechanisms, as provided by SMTP in [SMTP] and   [SMTP-DSN].  The same mechanism is also adopted for handling   transitory errors, that result in long idling periods, during an SMTP   transmission phase.  In order to guarantee that an error is returned   to the user, as defined insection 3.3.3, the system that handles PEC   traffic MUST adopt a time limit for message idleness equal to 24   hours.   Once a message arrives, the Incoming Point runs the following list of   checks and operations:   o  verifies correctness and type of the incoming message;   o  if the incoming message is a correct and undamaged PEC transport      envelope:      - emits a server-server acceptance PEC notification towards the        sender provider (section 3.2.1);      - forwards the PEC transport envelope to the Delivery Point        (section 3.3).   o  if the incoming message is a correct and undamaged PEC      notification, forwards the notification to the Delivery Point.   o  if the incoming message does not conform to the prerequisites of a      correct and undamaged PEC transport envelope or notification, but      comes from a PEC provider, i.e., passes the verifications      regarding existence, origin, and validity of the signature, then      the message MUST be propagated towards the recipient.      Therefore, the Incoming Point:      -  inserts the incoming message in a PEC anomaly envelope (section3.2.2);Petrucci, et al.              Informational                    [Page 14]

RFC 6109                Certified Electronic Mail             April 2011      -  forwards the PEC anomaly envelope to the Delivery Point.   o  if the incoming message does not originate from a PEC system,      i.e., fails verifications regarding existence, origin, and      validity of the signature, then the message will be treated as      ordinary email, and, if propagated to the recipient:      - is inserted in a PEC anomaly envelope (section 3.2.2);      - the PEC anomaly envelope is forwarded to the Delivery Point.      The server-server acceptance PEC notification is generated by the      receiving provider and sent to the sending provider.  Its purpose      is to keep track of the message in its transition from one      provider to another, and is therefore strictly intra-provider      communication; the end user knows nothing about it.      To check the correctness and integrity of a PEC transport envelope      or notification, the Incoming Point runs the following tests:   o  Signature existence - the system verifies the presence of an      S/MIME signature structure within the incoming message;   o  Signature origin - the system verifies whether or not the      signature belongs to a PEC provider by extracting the certificate      used for signing and verifying its presence in the PEC providers      directory.  To ease the check, it is possible to calculate the      certificate's [SHA1] hash value and perform a case-insensitive      search of its hexadecimal representation within the      "providerCertificateHash" attribute found in the PEC providers      directory.  This operation allows one to easily identify the      sender provider for subsequent and necessary matching checks      between the extracted certificate and the one present in the      provider's record;   o  Signature validity - S/MIME signature correctness is verified by      recalculating the signature value, checking the entire      certification path, and verifying the [CRL] and temporal validity      of the certificate.  In case some caching mechanism is used for      CRL contents, an update interval MUST be adopted so that the most      up-to-date data is guaranteed, thus minimizing the possible delay      between a publication revocation by the Certification Authority      and the variation acknowledgment by the provider;   o  Formal correctness - the provider performs sufficient and      necessary checks to guarantee that the incoming message is      compliant with the formats specified in this document (PEC      transport envelope and notifications).Petrucci, et al.              Informational                    [Page 15]

RFC 6109                Certified Electronic Mail             April 2011      If a virus-infected PEC transport envelope passes the checks just      mentioned, it is still considered correct and undamaged.  The      presence of the virus will be detected in a second phase, during      which the contents of the PEC transport envelope are verified.      Thus, the Incoming Point will refrain from forwarding the message      to the recipient, instead sending the appropriate PEC notification      of non-delivery and storing the virus-infected message in the      provider's special storage.      In case ordinary mail messages are received, the PEC provider      SHALL perform virus checks in order to prevent the infiltration of      potentially dangerous mail messages within the PEC system.  If a      virus is detected in an ordinary mail message, the latter can be      discarded at the Incoming Point before it enters the PEC system.      In other words, no special treatment is reserved for the error; it      is handled in a manner that is conformant to the procedures      usually followed for messages going through the Internet.      When the receiving provider detects a virus inside a PEC transport      envelope during the reception phase, it emits a virus detection      PEC notification to the sending provider, which then realizes its      checks failed to detect that virus.  When this happens, the      sending provider MUST:   o  check what virus typologies were not detected by its own antivirus      to verify the possibility of interventions   o  send a virus-induced non-delivery PEC notification to the sender's      mailbox.2.2.3.  Delivery Point   This point is the point that receives messages from the Incoming   Point and forwards them to the final recipient.   It MUST run a series of tests on received messages before forwarding   them to the user (seesection 3.3.1).  It first verifies the typology   of the message and decides whether or not a PEC notification should   be issued to the sender.  The delivery PEC notification (section3.3.2) is emitted after the message was delivered to the recipient's   PEC mailbox and only at reception of a valid PEC transport envelope   (sections2.2.2 and3.1.5).   In all other cases, such as PEC anomaly envelopes and PEC   notifications, the delivery PEC notification is not emitted.   Regardless, the message received from the Delivery Point MUST be   delivered unmodified to the recipient's mailbox.Petrucci, et al.              Informational                    [Page 16]

RFC 6109                Certified Electronic Mail             April 2011   The delivery PEC notification indicates to the sender that the   message sent was in fact conveyed to the specified recipient's   mailbox and certifies the date and time of delivery through use of   user-readable text and an XML part containing certification data,   along with other possible attachments added for extra features   offered by the provider.   If a PEC transport envelope received at the Delivery Point can't be   delivered to the destination mailbox, the Delivery Point emits a non-   delivery PEC notification (section 3.3.3).  If, on the other hand,   the delivery error concerns a message that arrives from Internet   (i.e., a non-PEC message), no such notification is emitted.2.2.4.  Storage   Each provider MUST dedicate a special storage for the deposition of   any virus-infected messages encountered.  Whether the virus be   detected by the sender's Access Point or the receiver's Incoming   Point, the provider that detects it MUST store the mail message in   its own storage, and keep it for 30 months.2.2.5.  Provider Service Mailbox   For exclusive use of the provider, dedicated to the reception of PEC   notifications in two cases only:   o  server-server acceptance notification; and   o  virus detection notification.2.2.6.  Provider Service Email Address   Each provider MUST register a special purpose email address for use   when sending PEC transport envelopes and notifications, as delineated   insection 3.  This address MAY coincide with that of the service   mailbox described insection 2.2.5.2.3.  Log   The server administrator MUST keep track of any and all operations   carried out in a specific message log file.  The information kept in   the log for each operation is the following:   o  message identifier (msgid)   o  date and time of event   o  sender of original messagePetrucci, et al.              Informational                    [Page 17]

RFC 6109                Certified Electronic Mail             April 2011   o  recipient(s) of original message   o  subject of original message   o  event type (reception, delivery, PEC notification emission, etc.)   o  message identifiers of related generated messages   o  sending provider   The service provider MUST store this data and preserve it unmodified.   Italian laws have specified that the service provider retain the data   for 30 months.3.  Message Processing3.1.  Access Point   The Access Point acts as a submission service as defined in   [SUBMISSION].3.1.1.  Formal Checks on Messages   When the Access Point receives a message the user wishes to send, it   MUST guarantee said message's formal conformity as defined in   [EMAIL], and verify that the:   o  [EMAIL] header section contains a "From:" header field holding an      [EMAIL] compliant email address;   o  [EMAIL] header section contains a "To:" header field holding one      or more [EMAIL] compliant email addresses;   o  sender's address, specified in the SMTP reverse path, coincides      with the one in the message's "From:" header field;   o  recipients' addresses specified in the SMTP forward path coincide      with the ones present in the "To:" or "Cc:" header fields of the      message;   o  "Bcc:" header field does not contain any value;   o  total message size falls within the limits accepted by the      provider.  Such limits apply depending on the number of recipients      as well; by multiplying it to the message size, the outcome MUST      fall within the limits accepted by the provider.  Italian laws      have specified this limit as being 30 MB.Petrucci, et al.              Informational                    [Page 18]

RFC 6109                Certified Electronic Mail             April 2011   If the message does not pass the tests, the Access Point MUST NOT   accept the message within the PEC system, thus emitting the relative   PEC notification of non-acceptance.3.1.2.  Non-Acceptance PEC Notification Due to Formal Exceptions   When the Access Point cannot forward the message received due to   failure in passing formal checks, the sender is notified of such an   outcome.  If the error is caused by the message failing size checks,   a non-acceptance PEC notification is sent as long as the size remains   bound by a certain limit.  If the size exceeds said limit, error   handling is left to SMTP.   The notification header will contain the following fields:        X-Ricevuta: non-accettazione        Date: [date of notification emission]        Subject: AVVISO DI NON ACCETTAZIONE: [original subject]        From: posta-certificata@[mail domain]        To: [original sender]        X-Riferimento-Message-ID: [msgid]   The notification body will contain a text part that constitutes the   actual notification in readable format according to a model that   relates the following information:      Error in message acceptance      On [date] at [time] ([time zone]), in the message "[subject]"      originating from "[original sender]" and addressed to:      [recipient_1]      [recipient_2]      [recipient_n]      a problem was detected that prevents its acceptance due to      [error description].      The message was not accepted.      Message identifier: [PEC msgid of corresponding      PEC transport envelope]   The same certification information is inserted in an XML file to be   added to the notification body, thus allowing automatic checks on the   message (section 4.4).  Parsing MUST be done on the XML part only.   Additional parts MAY be included by the provider for provider-   specific services.  Regardless, the original message MUST NOT be   included.  The message MUST follow the format described insection4.3.Petrucci, et al.              Informational                    [Page 19]

RFC 6109                Certified Electronic Mail             April 20113.1.3.  Non-Acceptance PEC Notification Due to Virus Detection   The Access Point MUST run some tests on the content of messages it   receives from its users and reject them if a virus is detected.  In   which case, a virus-detection-induced non-acceptance PEC notification   MUST be emitted to clearly inform the user of the reason the message   was refused.   The notification header contains the following fields:      X-Ricevuta: non-accettazione      X-VerificaSicurezza: errore      Date: [notification emission date]      Subject: AVVISO DI NON ACCETTAZIONE PER VIRUS: [original               subject]      From: posta-certificata@[mail domain]      To: [original sender]      X-Riferimento-Message-ID: [msgid]   The body contains a readable text part according to the following   model:      Error in message acceptance due to virus presence      On [date] at [time] ([time zone]), in the message "[subject]"      originating from "[original sender]" and addressed to:      [recipient_1]      [recipient_2]      [recipient_n]      a security problem was detected [ID of detected content type].      The message was not accepted.      Message identifier: [PEC msgid of corresponding      PEC transport envelope]   The same certification data is inserted in an XML file added to the   notification to allow for automatic checks (section 4.4).  Parsing   MUST be done on the XML part only.  Additional parts MAY be included   by the provider for provider-specific services.  Regardless, the   original message MUST NOT be included.  The message MUST follow the   format described insection 4.3.3.1.4.  Server-User Acceptance PEC Notification   The server-user acceptance PEC notification is a message sent to the   sender by his server, containing date and time of message acceptance   into the system, sender and recipient data, and subject.Petrucci, et al.              Informational                    [Page 20]

RFC 6109                Certified Electronic Mail             April 2011   The header contains the following fields:      X-Ricevuta: accettazione      Date: [actual date of server-user acceptance]      Subject: ACCETTAZIONE: [original subject]      From: posta-certificata@[mail domain]      To: [original sender]      X-Riferimento-Message-ID: [msgid]   The message body contains a text part that constitutes the   notification in readable format, according to a model that relates   the following information:      Server-User Acceptance PEC notification      On [date] at [time] ([time zone]), the message "[subject]"       originating from "[original sender]" and addressed to:      [recipient_1] (["certified mail" | "ordinary mail"])      [recipient_2] (["certified mail" | "ordinary mail"])      [recipient_n] (["certified mail" | "ordinary mail"])      was accepted by the system and forwarded to the recipient(s).      Message identifier: [PEC msgid of corresponding      PEC transport envelope]   The same certification data is inserted in an XML file added to the   notification message, allowing automatic checks on it (section 4.4).   Parsing MUST be done on the XML part only.  Additional parts MAY be   included by the provider for provider-specific services.  The message   MUST follow the format described insection 4.3.3.1.5.  PEC Transport Envelope   A PEC transport envelope is a message generated by the Access Point   that contains the original message as well as certification data.   As mentioned insection 2.1.1.2, the PEC transport envelope inherits   from the original message the values of the following header fields,   which MUST be related unmodified:   o  Received:   o  To:   o  Cc:   o  Return-Path:   o  Reply-To: (if present)Petrucci, et al.              Informational                    [Page 21]

RFC 6109                Certified Electronic Mail             April 2011   On the other hand, the following fields MUST be modified, or inserted   if necessary:      X-Trasporto: posta-certificata      Date: [actual date of server-user acceptance]      Subject: POSTA CERTIFICATA: [original subject]      From: "On behalf of: [original sender]"                           <certified-mail@[mail_domain]>      Reply-To: [original sender] (inserted only if not present)      Message-ID: [PEC msgid generated as insection 2.2.1]      X-Riferimento-Message-ID: [msgid]      X-TipoRicevuta: [completa/breve/sintetica]   The "X-TipoRicevuta:" field indicates the type of delivery PEC   notification the sender wishes to receive -- complete, brief, or   concise.   The body of the PEC transport envelope contains a text part that   constitutes the readable format of the message according to a model   that relates the following certification data:      Certified mail message      On [date] at [time] ([time zone]), the message "[subject]" was      sent by "[original sender]" and addressed to:      [recipient_1]      [recipient_2]      [recipient_n]      The original message is included in attachment.      Message identifier: [PEC msgid of corresponding      PEC transport envelope]   Within the PEC transport envelope, the entire, non-modified original   message is inserted in a format compliant with [EMAIL] (except for   what has been said regarding the message identifier), as well as an   XML part, which contains the certification data that was already   related in text format, and information on the type of message and   PEC notification requested (section 4.4).  Parsing MUST be done on   the XML part only.  Additional parts MAY be included by the provider   for provider-specific services.  The message MUST follow the format   described insection 4.3.   Note that the routing data of the PEC transport envelope (forward and   reverse paths) remain unaltered.Petrucci, et al.              Informational                    [Page 22]

RFC 6109                Certified Electronic Mail             April 20113.1.6.  Timeout Delivery Error PEC Notification   If the sending provider doesn't receive a server-server acceptance or   delivery PEC notification from the receiving provider within 12 hours   of the message dispatch, it informs the user that the recipient's   provider might not be able to deliver the message.  In case the   sending provider doesn't receive a delivery PEC notification within   24 hours after message dispatch, it emits another non-delivery PEC   notification to the user by the 24-hour timeout, but not before 22   hours have passed.   Such a communication takes place through a PEC notification of non-   delivery due to timeout, the header of which contains the following   fields:      X-Ricevuta: preavviso-errore-consegna      Date: [date of notification emission]      Subject: AVVISO DI MANCATA CONSEGNA PER SUP.  TEMPO MASSIMO:               [original subject]      From: posta-certificata@[mail domain]      To: [original recipient]      X-Riferimento-Message-ID: [msgid]   The body of the first non-delivery PEC notification (12-hour timeout)   contains a text part that represents the readable format of the   notification which will relate the following data:      Non-delivery PEC notification      On [date] at [time] ([time zone]), the message      "[subject]" originating from "[original sender]"      and addressed to "[recipient]"      has not been delivered within the first 12 hours following      its dispatch.  Not excluding that the message might eventually      be delivered, it is deemed useful to consider that dispatch      might not have a positive outcome.  The system will see to      sending another non-delivery PEC notification if in the      following twelve hours no confirmation is received from the      recipient.      Message identifier: [PEC msgid of corresponding      PEC transport envelope]   On the other hand, 24-hour-timeout induced PEC notifications, which   have the same header as described above, will have the following text   in their body:Petrucci, et al.              Informational                    [Page 23]

RFC 6109                Certified Electronic Mail             April 2011      Non-delivery PEC notification      On [date] at [time] ([time zone]), the message      "[subject]" originating from "[original sender]"      and addressed to "[recipient]"      has not been delivered within 24 hours of its dispatch.      The transaction is deemed to be considered terminated with a      negative outcome.      Message identifier: [PEC msgid of corresponding      PEC transport envelope]   The same certification data is inserted in an XML file added to both   PEC notification types to allow automatic checks (section 4.4).   Parsing MUST be done on the XML part only.  Additional parts MAY be   added for services supplied by the PEC provider.  Regardless, the   original message MUST NOT be included.  The message MUST follow the   format described insection 4.3.   A timeout PEC notification is generated if one of the following   scenarios occurs:   o  the sending provider receives a server-server acceptance PEC      notification during the first 12 hours following message dispatch,      but does not receive a delivery PEC notification at all.  In this      case, it would be a 24-hour timeout PEC notification.   o  the sending provider does not receive a server-server acceptance      PEC notification, but receives a delivery PEC notification after      12 hours and before the 24-hour timeout.  In this case it would be      a 12-hour timeout PEC notification.   o  the sending provider doesn't receive either a server-server      acceptance or a delivery PEC notification.  In this case, two      timeout PEC notifications are generated; a 12-hour and a 24-hour      timeout PEC notification.3.2.  Incoming Point3.2.1.  Server-Server Acceptance PEC Notification   When correct PEC transport envelopes (as defined insection 2.2.2.)   are exchanged between PEC providers, the receiver MUST send a server-   server acceptance PEC notification to the sender.  The single   dispatched notification concerns all recipients who belong to the   same provider, and to whom the incoming message was addressed, as   stated in the routing data (forward and reverse paths) of the SMTP   transaction.  Within the certification data of a single server-serverPetrucci, et al.              Informational                    [Page 24]

RFC 6109                Certified Electronic Mail             April 2011   acceptance PEC notification, all recipients of the message to which   it refers are listed.  In general, when receiving a PEC transport   envelope, each provider MUST emit one or more server-server   acceptance PEC notifications to cover, in absence of SMTP transport   errors, all the recipients in its jurisdiction.   The header of a server-server acceptance PEC notification contains   the following fields:      X-Ricevuta: presa-in-carico      Date: [date of server-server acceptance]      Subject: PRESA IN CARICO: [original subject]      From: posta-certificata@[mail domain]      To: [sender provider service mailbox]      X-Riferimento-Message-ID: [msgid]   The provider's service email address is obtained from the PEC   providers directory during the necessary queries made in the   signature verification stage.   The body contains a text part that follows the underlying model:      Server-server acceptance PEC notification      On [date] at [time] ([time zone]), the message "[subject]"      originating from "[original sender]" and addressed to:      [recipient_1]      [recipient_2]      [recipient_n]      was accepted by the system.      Message identifier: [PEC msgid of corresponding      PEC transport envelope]   The same certification data is inserted in an XML file which is added   to the notification message to allow for automatic checks (section4.4).  Parsing MUST be done on the XML part only.  Additional parts   MAY be added by the provider for provider-specific services.  The   message MUST follow the format described insection 4.3.3.2.2.  PEC Anomaly Envelope   If the tests on an incoming message detect an error, or the message   is identified as being ordinary mail and the provider is set to   forward it to the recipient, the system MUST insert such a message in   a PEC anomaly envelope.  Before delivery, the entire message receivedPetrucci, et al.              Informational                    [Page 25]

RFC 6109                Certified Electronic Mail             April 2011   at the Incoming Point is inserted in a format compliant with [EMAIL]   as a [MIME1] part inside a new message that MUST inherit the   unmodified values for the following header fields from the received   message:   o  Received:   o  To:   o  Cc:   o  Return-Path:   o  Message-ID:   Whereas, the following header fields MUST be modified or inserted:      X-Trasplorto: errore      Date: [mlessage arrival date]      Subject: ANOMALIA MESSAGGIO: [original subject]      From: "On behalf of: [original sender]"                             <posta-certificata@[mail_domain]>      Reply-To: [original sender (inserted only if not already                present)]   The body contains a user-readable text part according to a model that   relates the following data:      Message anomaly      On [date] at [time] ([time zone]), the message "[subject]"      originating from "[original sender]" and addressed to:      [recipient_1]      [recipient_2]      [recipient_n]      was received.      The data has not been certified due to the following error:      [concise description of error]      The original message is attached.   Due to uncertainty regarding origin and/or conformity of the message   received, the PEC anomaly envelope MUST NOT contain [MIME1] parts   other than the entire message that arrived at the Incoming Point.   Note that the routing data of such an envelope (forward and reverse   paths) remain unaltered.  Doing so guarantees both message forwarding   to the recipients, and reception of SMTP error notifications, if any   occur, by the sender (as specified in [SMTP] and [SMTP-DSN]).Petrucci, et al.              Informational                    [Page 26]

RFC 6109                Certified Electronic Mail             April 20113.2.3.  Virus Detection PEC Notification   If the Incoming Point receives virus-infected PEC messages, it MUST   NOT forward them.  Rather it MUST inform the sending provider, which   will in turn inform the sending user, of the failed transmission.  A   separate PEC notification of virus detection MUST be sent on behalf   of every recipient within the provider's domain.   In case a virus is detected during the reception phase of a message   whose origin was asserted through sender signature verification, the   system generates a virus-detected PEC notification indicating the   error found, and sends it to the sending provider's service mailbox.   The header of this PEC notification contains the following fields:      X-Ricevuta: rilevazione-virus      X-Mittente: [original sender]      Date: [date of notification emission]      Subject: PROBLEMA DI SICUREZZA: [original subject]      From: posta-certificata@[mail domain]      To: [sender provider notifications]      X-Riferimento-Message-ID: [msgid]   The body contains a readable text part according to a model that   relates the following data:      Virus detection PEC notification      On [date] at [time] ([time zone]), in the message "[subject]"      originating from "[original sender]" and addressed to      "[recipient]"      a security problem was detected [ID of content type detected].      Message identifier: [PEC msgid of corresponding      PEC transport envelope]   The same certification data is inserted in an XML file and added to   the notification to allow for automatic checks (section 4.4).   Parsing MUST be done on the XML part only.  Additional parts MAY be   included by the provider for provider-specific services.  Regardless,   the original message MUST NOT be included.  The message MUST follow   the format described insection 4.3.   The message body MUST contain the reason for which the transmission   could not be completed.Petrucci, et al.              Informational                    [Page 27]

RFC 6109                Certified Electronic Mail             April 20113.2.4.  Virus-Induced Delivery Error PEC notification   At the reception of a virus detection PEC notification from the   receiving provider, the sender provider emits a non-delivery PEC   notification to the sending user.   The header for this notification contains the following fields:      X-Ricevuta: errore-consegna      X-VerificaSicurezza: errore      Date: [date of notification emission]      Subject: AVVISO DI MANCATA CONSEGNA PER VIRUS: [original               subject]      From: posta-certificata@[mail domain]      To: [original sender]      X-Riferimento-Message-ID: [msgid]   The body contains a readable text part according to a model that   relates the following data:      Delivery error PEC notification due to virus      On [date] at [time] ([time zone]), in the message "[subject]"      addressed to "[recipient]"      a security problem was detected [ID of content type detected      by the anti-virus].      The message was not delivered.      Message identifier: [PEC msgid of corresponding      PEC transport envelope]   All the information necessary for the construction of such a PEC   notification can be obtained from the correlated virus-detected PEC   notification.   The same certification data is inserted in an XML file and added to   the notification message to allow for automatic checks (section 4.4).   Parsing MUST be done on the XML part only.  Additional parts MAY be   included by the provider for provider-specific services.  The reason   the transaction was not completed MUST be specified in the message,   which MUST follow the format described insection 4.3.Petrucci, et al.              Informational                    [Page 28]

RFC 6109                Certified Electronic Mail             April 20113.3.  Delivery Point3.3.1.  Checks on Incoming Messages   When a message arrives at the Delivery Point, the system verifies:   o  message type   o  whether or not a PEC notification has to be returned.3.3.2.  Delivery PEC Notification   A delivery PEC notification is issued only after a correct PEC   transport envelope (sections2.2.2 and3.1.5) has been delivered to   the recipient's mailbox.   In all other cases (e.g., PEC anomaly envelopes, PEC notifications),   the delivery PEC notification is not issued.  Regardless, the message   received at the Delivery Point MUST be delivered to the recipient's   mailbox unchanged.   This notification tells the user that his/her message has been   successfully delivered to the specified recipient.  It includes   readable text that certifies the date and time of delivery, sender   and receiver data, and the subject.  It also contains an XML   certification data file and other optional parts for functionalities   offered by the provider.   The following fields are inserted in the header:      X-Ricevuta: avvenuta-consegna      Date: [delivery date]      Subject: CONSEGNA: [original subject]      From: posta-certificata@[mail domain]      To: [original sender]      X-Riferimento-Message-ID: [msgid]   The value of the "X-TipoRicevuta:" header field in the PEC transport   envelope is derived from the original message, thus allowing the   sender to determine the type of delivery PEC notification requested   from the primary recipients of the original message.  The   notification MUST follow the format described insection 4.3.3.3.2.1.  Delivery PEC Notification: Complete   This is the default value for delivery PEC notifications.  When no   value for "X-TipoRicevuta:" is specified, or when it contains the   value "completa" (complete), the system will require a completePetrucci, et al.              Informational                    [Page 29]

RFC 6109                Certified Electronic Mail             April 2011   delivery PEC notification from addressees in the "To:" field, while a   concise PEC notification (section 3.3.2.3) will be required from   those in the "Cc:" field.  The distinction between primary recipients   and those in carbon copy is done through an analysis of the "To:" and   "Cc:" fields.  For PEC notifications sent on behalf of primary   recipients, a complete copy of the original message along with any   attachments is inserted in the notification.  In case the system in   charge of delivery is not able to determine the recipient type due to   ambiguity problems in the "To:" and "Cc:" fields, delivery MUST be   considered as if addressed to a primary recipient and include the   complete copy of the original message.   The notification body contains a readable text part that relates   certification data according to the following model:      Delivery PEC notification      On [date] at [time] ([time zone]), the message "[subject]"      originating from "[original sender]" and addressed to      "[recipient]"      was placed in the destination's mailbox.      Message identifier: [PEC msgid of corresponding      PEC transport envelope]   The same certification data is inserted in an XML file and added to   the notification (section 4.4), along with any other parts that MAY   be inserted by the provider for provider-specific services.  Parsing   MUST be done on the XML part only.  The delivery PEC notification   MUST be issued on behalf of every recipient of the message, and MUST   follow the format described insection 4.3.3.3.2.2.  Delivery PEC Notification: Brief   In order to decrease the amount of data flowing, it is possible for   the sender to ask for a delivery PEC notification in "brief" format.   The brief delivery PEC notification contains the original message and   a ciphered hash value for each of its parts.  The hash value SHOULD   be calculated on base64 encoded parts.  As specified insection 5.3,   PEC messages MUST transit only on machines that belong to the PEC   network and that MUST NOT alter the encoding of the message during   its transition/processing.   NOTE: Even though PEC uses these relaxed specifications, PEC   interoperability tests between over 20 service providers have never   revealed any problems.  This is probably due to mail servers leaning   more towards leaving the messages they receive intact withoutPetrucci, et al.              Informational                    [Page 30]

RFC 6109                Certified Electronic Mail             April 2011   applying any changes.  But issues might arise if a server decides to   modify encoded parts; for example, change the base64 line length,   whose hash value calculated at the receiver's end would then differ   from that at the sender's side.   To be able to verify the transmitted contents it is necessary for the   sender to keep the unaltered original copy of the part(s) to which   the hash values refer.   If the PEC transport envelope contains the header:        X-TipoRicevuta: breve   the Delivery Point emits a brief delivery PEC notification on behalf   of the primary recipients, and a concise one (section 3.3.2.3) on   behalf of carbon copy recipients.  The value of the header field in   the PEC transport envelope is derived from the original message.   The notification body contains a readable text part according to a   model that relates the following certification data:      Brief delivery PEC notification      On [date] at [time] ([time zone]), the message "[subject]"      originating from "[original sender]" and addressed to      "[recipient]"      was placed in the destination's mailbox.      Message identifier: [PEC msgid of corresponding      PEC transport envelope]   The same certification data is inserted in an XML file and added to   the notification (section 4.4), along with other parts that MAY be   included for specific provider-supplied services.  Parsing MUST be   done on the XML part only.  The delivery PEC notification is issued   on behalf of every recipient of the message, and MUST follow the   format described insection 4.3.   The MIME structure of the original message is unaltered as it is   added to the notification, but each MIME part with a "name" parameter   in the header field "Content-Type:" or a "filename" parameter in the   header field "Content-Disposition:" MUST be substituted by a text   file containing that MIME part's hash value.   When the original message has an S/MIME format, it is necessary not   to alter the integrity of the message structure.  Verification of the   S/MIME part in the original message takes place when the MIME type of   the top-level entity (which coincides with the message itself) is   checked.  An S/MIME message MAY have the following MIME types (as per   [SMIMEV3]):Petrucci, et al.              Informational                    [Page 31]

RFC 6109                Certified Electronic Mail             April 2011   o  multipart/signed      Represents an original message signed by the sender using the      structure described in [MIME-SECURE].  The message is made up of      two MIME parts: the first is the message itself before the      application of the sender's signature, whereas the second contains      signature data.  The second part (generally of type      "application/pkcs7-signature" or "application/x-pkcs-signature")      contains data added during the signing phase and MUST be left      unchanged to avoid compromising the overall message structure;   o  "application/pkcs7-mime" or "application/x-pkcs7-mime"      The message is composed of a sole CMS object within the MIME part.      Given that attachments cannot be separated from the CMS object,      the MIME part is left intact (i.e., it is not replaced by the hash      value); therefore, the brief PEC notification is the same as the      complete PEC notification.   If the original message contains parts whose "Content-Type:" is   "message/rfc822", i.e., contains an email message as attachment, the   entire attached message is substituted with its corresponding hash   value.   Therefore, when emitting a brief delivery PEC notification, the   provider MUST:   1. identify and extract all the parts from the first MIME part of the     multipart/signed S/MIME message;   2. calculate the hash values of all the files attached by the sender     to the original message;   3. substitute originals with their hash values.   In general, in the case of original messages in S/MIME format, the   copy of the message inserted within the brief delivery PEC   notification will have the following characteristics:   o  if the original message is signed, the S/MIME structure and      signature-relative data will remain unchanged.  The message will      generate an error in a future signature integrity verification      phase following the substitution of attachments with the      corresponding hash values.   o  if the original message contains the "application/pkcs7-mime" or      "application/x-pkcs7-mime" MIME type, attachments present in the      message will not be substituted by their hash values, due toPetrucci, et al.              Informational                    [Page 32]

RFC 6109                Certified Electronic Mail             April 2011      impossibility of identification within a CMS structure.  The      content of the brief delivery PEC notification will coincide with      that of a normal delivery PEC notification.   The algorithm used for hash calculation is the [SHA1], calculated on   the entire content of the part.  To allow distinction between hash   files and the files to which they refer, the suffix ".hash" is added   to the original filename.  The hash value is written in the file   using a hexadecimal representation as a single sequence of 40   characters.  The MIME type of these attachments is set to   "text/plain" to highlight their textual nature.3.3.2.3.  Delivery PEC Notification: Concise   If the PEC transport envelope contains the header:        X-TipoRicevuta: sintetica   the Delivery Point emits, both to primary and carbon copy recipients,   a concise delivery PEC notification that does not contain the   original message.   The message body of the notification contains a readable text part   according to a model that relates the following certification data:      Concise delivery PEC notification      On [date] at [time] ([time zone]), the message "[subject]"      originating from "[original sender]" and addressed to      "[recipient]"      was placed in the destination's mailbox.      Message identifier: [PEC msgid of corresponding      PEC transport envelope]   The same certification data is inserted within an XML file and added   to the notification (section 4.4), along with additional parts that   MAY be included for provider-specific services.  Parsing MUST be done   on the XML part only.  The notification is sent to each one of the   recipients to whom the message is delivered, and MUST follow the   format described insection 4.3.   The concise delivery PEC notification follows the same emission rules   as the delivery PEC notification; added to it is only the XML file   containing the certification data, not the original message.Petrucci, et al.              Informational                    [Page 33]

RFC 6109                Certified Electronic Mail             April 20113.3.3.  Non-Delivery PEC Notification   If an error occurs during the delivery of a correct PEC transport   message, the system returns to the sender a non-delivery PEC   notification that indicates the error condition.   The header will contain the following fields:      X-Ricevuta: errore-consegna      Date: [date of notification emission]      Subject: AVVISO DI MANCATA CONSEGNA: [original subject]      From: posta-certificata@[mail domain]      To: [original sender]      X-Riferimento-Message-ID: [msgid]   The notification body contains a readable text part according to a   model that relates the following data:      Non-delivery PEC notification      On [date] at [time] ([time zone]), in the message "[subject]"      originating from "[original sender]" and addressed to      "[recipient]"      an error was detected [brief error description].      The message was refused by the system.      Message identifier: [PEC msgid of corresponding      PEC transport envelope]   The same certification data is inserted within an XML file and added   to the notification in order to allow for automatic checks (section4.4).  Parsing MUST be done on the XML part only.  Additional parts   MAY be included by the PEC provider for provider-specific services.   The notification MUST follow the format described insection 4.3.3.4.  Sender and Receiver Belonging to the Same Domain   PEC messages MUST be processed even if both sender and receiver(s)   belong to the same PEC domain.3.5.  Example: Complete Transaction between Two PEC Domains   A correct transaction between two PEC domains goes through the   following steps:   o  The sending user sends an email to his provider's Access Point;   o  The Access Point runs all checks and emits a server-user      acceptance PEC notification to the user;Petrucci, et al.              Informational                    [Page 34]

RFC 6109                Certified Electronic Mail             April 2011   o  The Access Point creates a PEC transport envelope and forwards it      to the Incoming Point of the receiving provider;   o  The receiver's Incoming Point verifies the PEC transport envelope      and creates a server-server acceptance PEC notification to be sent      to the sending provider;   o  The sender's Incoming Point verifies the validity of the server-      server acceptance PEC notification and forwards it to the Delivery      Point;   o  The sender's Delivery Point saves the server-server acceptance PEC      notification in the provider's service mailbox;   o  The receiver's Incoming Point forwards the PEC transport envelope      to the receiver's Delivery Point;   o  The receiver's Delivery Point verifies the contents of the PEC      transport envelope and saves it in the recipient's mailbox;   o  The receiver's Delivery Point creates a delivery PEC notification      and sends it to the sender's Incoming Point;   o  The sender's Incoming Point verifies the validity of the delivery      PEC notification and forwards it to the sender's Delivery Point;   o  The sender's Delivery Point saves the delivery PEC notification in      the sending user's mailbox;   o  The receiving user has the message at his disposition.   NOTE: Some of these steps might occur in parallel, thus the   interaction might complete in a different order.4.  Formats4.1.  Temporal Reference   For all operations carried out during message, notification, and log   elaboration processes by the Access, Incoming, and Delivery Points,   it is necessary to have an accurate temporal reference available.   All events (generation of PEC notifications, transport envelopes,   logs, etc.) that constitute the transaction of message elaboration at   the Access, Incoming, and Delivery Points MUST employ a sole temporal   value obtained from within the transaction itself.Petrucci, et al.              Informational                    [Page 35]

RFC 6109                Certified Electronic Mail             April 2011   Doing this renders the instant of message elaboration unambiguous   within PEC logs, notifications, messages, etc., generated by the   server.4.2.  User Date/Time   Temporal indications supplied by the service in readable format (text   in PEC notifications, transport envelopes, etc.) are provided with   reference to the legal time at the moment of the operation.   Following is the specification using the syntax description notation   defined in [ABNF].   date-fullyear   = 4DIGIT   date-month      = 2DIGIT  ; 01-12   date-mday       = 2DIGIT  ; 01-28, 01-29, 01-30, 01-31 based on                             ; month/year   time-hour       = 2DIGIT  ; 00-23   time-minute     = 2DIGIT  ; 00-59   time-second     = 2DIGIT  ; 00-58, 00-59, 00-60 based on leap second                             ; rules   time-offset     = "(" ("+" / "-") time-hour ":" time-minute ")"   partial-time    = time-hour ":" time-minute ":" time-second   full-date       = date-mday "/" date-month "/" date-fullyear   full-time       = partial-time time-offset   NOTE: For number of days in a month, leap year, and leap second         restrictions see section 5.7 of [TIMESTAMP].4.3.  Format of a PEC Message Body   This section describes the characteristics of the various components   of PEC messages and notifications generated by a PEC system.  If one   of the message parts contains characters with values outside of the   range 0-127 (7-bit ASCII), that part will have to be adequately   encoded so that 7-bit transportation compatibility is guaranteed   (e.g., quoted-printable, base64 as per [MIME1]).   Before applying the signature, the message body has Content-Type:   multipart/mixed.  Each part is described in the sections below.  The   first part is the user readable text generated by the PEC system,   while the second and third parts are interchangeable in order and   contain the original message and the XML file for the certification   data.Petrucci, et al.              Informational                    [Page 36]

RFC 6109                Certified Electronic Mail             April 20114.3.1.  User Readable Text   Character set: ISO-8859-1 (Latin-1)   MIME type: text/plain or multipart/alternative   The multipart/alternative MIME type MAY be used to add an HTML   version of the body of system-generated messages.  In this case, two   sub-parts MUST be present: one of type text/plain, the other   text/html.  For the HTML part:   o  it MUST contain the same information as related in the text part;   o  it MUST NOT contain references to elements (e.g., images, sounds,      font, style sheets), neither internal to the message (added MIME      parts) nor external (e.g., hosted on the provider's server);   o  it MUST NOT have active content (e.g., JavaScript, VBscript, Plug-      in, ActiveX).4.3.2.  Original Message   MIME type: message/rfc822   Attachment name: postacert.eml4.3.3.  Certification Data   Character set: UTF-8   MIME type: application/xml   Attachment name: certdata.xml4.4.  Certification Data Scheme   Following is the DTD relative to the [XML] file that contains   certification data attached to PEC notifications.   <!--Use the element "postacert" as root-->   <!--"tipo" indicates the typology of the PEC message-->   <!--The attribute "errore" can have the following values-->   <!--"nessuno" = no error-->   <!--"no-dest" (with type="errore-consegna") = -->   <!--                                        wrong recipient-->   <!--"no-dominio" (with type="errore-consegna") = -->   <!--                                           wrong domain-->   <!--"virus" (with type="errore-consegna") = virus-->   <!--"virus" (with type="non-accettazione") = virus-->   <!--"altro" = generic error-->   <!ELEMENT postacert (intestazione, dati)>   <!ATTLIST postacertPetrucci, et al.              Informational                    [Page 37]

RFC 6109                Certified Electronic Mail             April 2011         tipo (accettazione |               non-accettazione |               presa-in-carico |               avvenuta-consegna |               posta-certificata |               errore-consegna |               preavviso-errore-consegna |               rilevazione-virus) #REQUIRED         errore (nessuno |                 no-dest |                 no-dominio |                 virus |                 altro) "nessuno">   <!--Header of the original message-->   <!ELEMENT intestazione (mittente,                           destinatari+,                           risposte,                           oggetto?)>   <!--Sender ("From:" field) of the original message-->   <!ELEMENT mittente (#PCDATA)>   <!--Complete list of recipients ("To:" and "Cc:" fields)-->   <!--of the original message-->   <!--"tipo" indicates the typology of the recipient-->   <!ELEMENT destinatari (#PCDATA)>   <!ATTLIST destinatari         tipo (certificato | esterno) "certificato">   <!--Value of the "Reply-To:" field of the original message-->   <!ELEMENT risposte (#PCDATA)>   <!--Value of the "Subject:" field of the original message-->   <!ELEMENT oggetto (#PCDATA)>   <!--PEC message data-->   <!ELEMENT dati (gestore-emittente,                   data,                   identificativo,                   msgid?,                   ricevuta?,                   consegna?,                   ricezione*,                   errore-esteso?)>   <!--Descriptive string of the provider that certifies -->   <!--the data-->   <!ELEMENT gestore-emittente (#PCDATA)>Petrucci, et al.              Informational                    [Page 38]

RFC 6109                Certified Electronic Mail             April 2011   <!--Date/time of message elaboration-->   <!--"zona" is the difference between local time and UTC in -->   <!--"[+|-]hhmm" format-->   <!ELEMENT data (giorno, ora)>   <!ATTLIST data         zona CDATA #REQUIRED>   <!--Day in "dd/mm/yyyy" format-->   <!ELEMENT giorno (#PCDATA)>   <!--Local hour in "hh:mm:ss" format-->   <!ELEMENT ora (#PCDATA)>   <!--PEC msgid-->   <!ELEMENT identificativo (#PCDATA)>   <!--msgid of the original message before modifications-->   <!ELEMENT msgid (#PCDATA)>   <!--For PEC transport envelopes and delivery notifications-->   <!--indicate the type of PEC notification requested by the-->   <!--sender-->   <!ELEMENT ricevuta EMPTY>   <!ATTLIST ricevuta         tipo (completa |               breve   |               sintetica ) #REQUIRED>   <!--For delivery, non-delivery, virus-induced non-delivery, -->   <!-- virus detection, and timeout PEC notifications-->   <!--Recipient address to which delivery has been carried -->   <!--out/tried-->   <!ELEMENT consegna (#PCDATA)>   <!--For server-server acceptance PEC notifications-->   <!--recipients for whom it is the relative PEC notification-->   <!ELEMENT ricezione (#PCDATA)>   <!--In case of error-->   <!--brief description of the error-->   <!ELEMENT errore-esteso (#PCDATA)>4.5.  PEC Providers Directory Scheme   The PEC providers directory is created through a centralized LDAP   server that contains the providers' data and their corresponding PEC   mail domains.Petrucci, et al.              Informational                    [Page 39]

RFC 6109                Certified Electronic Mail             April 2011   The following are the directory scheme's attributes:   - providerCertificateHash: hash of provider's certificate   - providerCertificate: provider certificate   - providerName: provider name   - mailReceipt: provider reception email address   - managedDomains: managed domains   - LDIFLocationURL: provider LDIF record URL   - providerUnit: secondary operating environment name   The directory's base root is "o=postacert" and the   "DistinguishedName" of single records is of the type   "<providerName=<name>,o=postacert>".  Search within the directory is   carried out mainly in case-sensitive mode using the   "providerCertificateHash" attribute (during envelope signature   verification phase) or the "managedDomains" attribute (during message   acceptance phase).  It is possible for the record of a single   provider to contain multiple "providerCertificate" attributes with   the related "providerCertificateHash" attributes in order to allow   the handling of the renewal of expiring certificates.  The provider   MUST make sure to update its record with sufficient advance before   the certificate expiration date, by adding a new certificate whose   validity overlaps that of the previous one.   The data of all PEC providers is encompassed in a [LDIF] file, which   is available as an [HTTPS] object and can be found at the URL to   which the 'LDIFLocationURL' attribute in the "dn: o=postacert" record   points (seesection 4.5.6).  To guarantee authenticity, that file   MUST be signed by the provider for the operations regarding its PEC   services using the method described for single providers.  The file,   the signature, and the X.509v3 certificate MUST be inserted in a   PKCS#7 structure in binary ASN.1 DER format as a file with ".p7m"   extension.  The centralized [LDAP] system downloads that file on a   daily basis and, after suitable verifications of the signature,   applies it to the provider's record.   Through the [LDIF] file, single providers MUST keep a copy of the   directory locally, updated on a daily basis, in order to improve   system performance by avoiding continuous request dispatches to the   central system for every message elaboration phase.Petrucci, et al.              Informational                    [Page 40]

RFC 6109                Certified Electronic Mail             April 2011   If secondary environments are present, the [LDIF] file indicated in   the main environment's record MUST relate the contents of all the   provider-relevant records.      NOTE: This specification uses an unregistered LDAP DN name space            that may lead to conflict with other registered or            unregistered names.4.5.1.  providerCertificateHash Attribute   The 'providerCertificateHash' attribute is a hexadecimal   representation of the hash in SHA1 format of the X.509v3 certificate   used by the provider for PEC notifications and envelope signatures.   ( 1.3.6.1.4.1.16572.2.2.1  NAME 'providerCertificateHash'     DESC 'Hash SHA1 of X.509 certificate in hexadecimal format'     EQUALITY caseIgnoreIA5Match     SYNTAX 1.3.6.1.4.1.1466.115.121.1.26 )   The IA5String ( 1.3.6.1.4.1.1466.115.121.1.26 ) syntax is defined in   [LDAP-SYNTAXES].4.5.2.  providerCertificate Attribute   The 'providerCertificate' attribute holds a set of certificate(s)   used by the provider to sign PEC notifications and transport   envelopes.   ( 1.3.6.1.4.1.16572.2.2.2  NAME 'providerCertificate'     DESC 'X.509 certificate in ASN.1 DER binary format'     SYNTAX 1.3.6.1.4.1.1466.115.121.1.8 )   The Certificate syntax ( 1.3.6.1.4.1.1466.115.121.1.8 ) is defined in   [RFC4523].   As required by this attribute type's syntax, values of this attribute   are requested and transferred using the attribute description   "providerCertificate;binary" [RFC4522].4.5.3.  providerName Attribute   The 'providerName' attribute contains the name of the PEC provider.   All records MUST contain their provider's name in this attribute.Petrucci, et al.              Informational                    [Page 41]

RFC 6109                Certified Electronic Mail             April 2011   ( 1.3.6.1.4.1.16572.2.2.3  NAME 'providerName'     DESC 'PEC provider name'     EQUALITY caseIgnoreMatch     SUBSTR caseIgnoreSubstringsMatch     SYNTAX 1.3.6.1.4.1.1466.115.121.1.15     SINGLE-VALUE )   The Directory String ( 1.3.6.1.4.1.1466.115.121.1.15 ) syntax is   defined in [LDAP-SYNTAXES].4.5.4.  mailReceipt Attribute   The 'mailReceipt' attribute contains the provider's email address   within the provider to which server-server acceptance and virus   detection PEC notifications are sent.  This address is a limited   version of the addr-spec construct described in [EMAIL] (without   angle brackets); it only permits the dot-atom-text form on both the   left- and right-hand sides of the "@", and does not have internal   CFWS.   ( 1.3.6.1.4.1.16572.2.2.4 NAME 'mailReceipt'     DESC 'E-mail address of the service mailbox'     EQUALITY caseIgnoreIA5Match     SUBSTR caseIgnoreIA5SubstringsMatch     SYNTAX 1.3.6.1.4.1.1466.115.121.1.26     SINGLE-VALUE )   The IA5String ( 1.3.6.1.4.1.1466.115.121.1.26 ) syntax is defined in   [LDAP-SYNTAXES].4.5.5.  managedDomains Attribute   The 'managedDomains' attribute holds a set of domains [SMTP] that are   handled by a PEC provider.  Domains are limited to dot-atom form   ([RFC1034], [EMAIL]).   ( 1.3.6.1.4.1.16572.2.2.5 NAME 'managedDomains'     DESC 'Domains handled by the PEC provider'     EQUALITY caseIgnoreIA5Match     SUBSTR caseIgnoreIA5SubstringsMatch     SYNTAX 1.3.6.1.4.1.1466.115.121.1.26 )   The IA5String ( 1.3.6.1.4.1.1466.115.121.26 ) syntax is defined in   [LDAP-SYNTAXES].   The 'managedDomains' attribute holds a set of domains [SMTP] that are   handled by a PEC provider.  Domains are limited to dot-atom form   ([RFC1034], [EMAIL]).Petrucci, et al.              Informational                    [Page 42]

RFC 6109                Certified Electronic Mail             April 20114.5.6.  LDIFLocationURL Attribute   The 'LDIFLocationURL' attribute contains an [HTTPS] URL that points   to the location of the [LDIF] file defining the provider's record.   When the attribute is present in the record "dn: o=postacert", then   it contains the definition of the entire directory in [LDIF] format.   The LDIF file will have a MIME type of application/pkcs7-mime, with   the parameter smime-type/signed-data.  [SMIMEV3] The LDIF file is   encoded using the UTF-8 character set.   Secondary environment records MUST NOT contain the 'LDIFLocationURL'   attribute which is obtained from the main environment's attributes   for all records connected to the provider.   ( 1.3.6.1.4.1.16572.2.2.6 NAME 'LDIFLocationURL'     DESC 'URL of the LDIF file that defines the entry'     EQUALITY caseExactMatch     SYNTAX 1.3.6.1.4.1.1466.115.121.1.15     SINGLE-VALUE )   The Directory String ( 1.3.6.1.4.1.1466.115.121.1.15 ) syntax is   defined in [LDAP-SYNTAXES].4.5.7.  providerUnit Attribute   The 'providerUnit' attribute contains the name of secondary operating   environments -- an attribute not present for the main environment.   It is possible for the provider to define several distinct records,   each indicating a single, different, secondary operating environment,   for which it is possible to declare specific attributes that are, if   need be, distinct from those relative to the main and other   environments.   The "DistinguishedName" of the records relative to the secondary   operating environments are of the type   "<providerUnits=<environment>,providerName=<name>,o=postacert>".   Every provider MUST have a record associated to its own main   environment, distinguishable for the absence of the "providerUnit"   attribute within the record and the DistinguishedName.   ( 1.3.6.1.4.1.16572.2.2.7 NAME 'providerUnit'     DESC 'Name of the secondary operative environment'     EQUALITY caseIgnoreMatch     SUBSTR caseIgnoreSubstringsMatch     SYNTAX 1.3.6.1.4.1.1466.115.121.1.15     SINGLE-VALUE )Petrucci, et al.              Informational                    [Page 43]

RFC 6109                Certified Electronic Mail             April 2011   The Directory String ( 1.3.6.1.4.1.1466.115.121.1.15 ) syntax is   defined in [LDAP-SYNTAXES].4.5.8.  LDIFLocationURLObject Object Class   The schema definition of the 'LDIFLocationURLObject' object class:   ( 1.3.6.1.4.1.16572.2.1.1 NAME 'LDIFLocationURLObject'     SUP top AUXILIARY     MAY ( LDIFLocationURL ) )4.5.9.  Provider Object Class   The schema definition of the 'provider' object class:   ( 1.3.6.1.4.1.16572.2.1.2 NAME 'provider'     SUP top STRUCTURAL     MUST ( providerCertificateHash            providerCertificate            providerName            mailReceipt            managedDomains )     MAY ( description           LDIFLocationURL           providerUnit )4.5.10.  LDIF File Example   The following LDIF file represents an example of a providers'   directory, containing a base root and two fictitious providers.  The   inserted certificates are two self-signed certificates used for   example purposes only:       dn: o=postacert       objectclass: top       objectclass: organization       objectClass: LDIFLocationURLObject       o: postacert       LDIFLocationURL:https://igpec.rupa.example.com/igpec.ldif.p7m       description: Base root for the PEC providers directory       dn: providerName=Anonymous Certified Mail S.p.A.,o=postacert       objectclass: top       objectclass: provider       providerName: Anonymous Certified Mail S.p.A.       providerCertificateHash:        7E7AEF1059AE0F454F2643A95F69EC3556009239       providerCertificate;binary::Petrucci, et al.              Informational                    [Page 44]

RFC 6109                Certified Electronic Mail             April 2011        MIIDBjCCAm+gAwIBAgIBADANBgkqhkiG9w0BAQQFADBmMQswCQYDVQQGEw        JJVDEpMCcGA1UEChMgQW5vbmltYSBQb3N0YSBDZXJ0aWZpY2F0YSBTLnAu        QS4xLDAqBgkqhkiG9w0BCQEWHXBvc3RhLWNlcnRpZmljYXRhQGFucG9jZX        J0Lml0MB4XDTAyMTIwOTE3MjQxNVoXDTAzMTIwOTE3MjQxNVowZjELMAkG        A1UEBhMCSVQxKTAnBgNVBAoTIEFub25pbWEgUG9zdGEgQ2VydGlmaWNhdG        EgUy5wLkEuMSwwKgYJKoZIhvcNAQkBFh1wb3N0YS1jZXJ0aWZpY2F0YUBh        bnBvY2VydC5pdDCBnzANBgkqhkiG9w0BAQEFAAOBjQAwgYkCgYEAr8J+qK        KdxV9LzDMPqwnEy0P8H/KwbI0Szs8p6UZajZdpeUK0Ncbrv1QyXZNNtSMC        2uL09HDyx8agjgZWdhypnehguiSK3busha15RSpMGhiqxmz2b0HhOG73Gf        alZelqrwqmElna4MNUaLhbOvTd/sqPUS378w5IaIhWxzy34XcCAwEAAaOB        wzCBwDAdBgNVHQ4EFgQUN8lC0znQWEs0xspZ/aBzsaGvRZMwgZAGA1UdIw        SBiDCBhYAUN8lC0znQWEs0xspZ/aBzsaGvRZOhaqRoMGYxCzAJBgNVBAYT        AklUMSkwJwYDVQQKEyBBbm9uaW1hIFBvc3RhIENlcnRpZmljYXRhIFMucC        5BLjEsMCoGCSqGSIb3DQEJARYdcG9zdGEtY2VydGlmaWNhdGFAYW5wb2Nl        cnQuaXSCAQAwDAYDVR0TBAUwAwEB/zANBgkqhkiG9w0BAQQFAAOBgQA58B        Z+q1qSKpuffzTBpMtbeFkDIxMqMa+ycnxdMNvcWgCm1A9ZiFJsvqYhDDqA        XxfHjkrzXuSZkYq6WiQCsLp0aYVy40QCIwbOunhrvsxh3vsG5CgN76JzZ9        5Z/1OCFNhLfqf1VH2NSS8TaYCCi/VO7W1Q1KkcA2VlxlQP7McSUw==       mailReceipt: ssacceptance@postalser.example.com       LDIFLocationURL: https://anpocert.example.com/anpocert.ldif.p7m       managedDomains: mail.anpocert.example.com       managedDomains: cert.company.example.com       managedDomains: costmec.example.com       description: Certified mail services for companies       dn: providerName=Postal Services S.p.A,o=postacert       objectclass: top       objectclass: provider       providerName: Postal Services S.p.A       providerCertificateHash:        e00fdd9d88be0e2cc766b893315caf93d5701a6a       providerCertificate;binary::        MIIDHjCCAoegAwIBAgIBADANBgkqhkiG9w0BAQQFADBuMQswCQYDVQQGEw        JJVDEfMB0GA1UEChMWU2Vydml6aSBQb3N0YWxpIFMuci5sLjEPMA0GA1UE        CxMGRC5DLkMuMS0wKwYJKoZIhvcNAQkBFh5wb3N0YS1jZXJ0aWZpY2F0YU        BzZXJwb3N0YWwuaXQwHhcNMDIxMjA5MTczMjE2WhcNMDMxMjA5MTczMjE2        WjBuMQswCQYDVQQGEwJJVDEfMB0GA1UEChMWU2Vydml6aSBQb3N0YWxpIF        Muci5sLjEPMA0GA1UECxMGRC5DLkMuMS0wKwYJKoZIhvcNAQkBFh5wb3N0        YS1jZXJ0aWZpY2F0YUBzZXJwb3N0YWwuaXQwgZ8wDQYJKoZIhvcNAQEBBQ        ADgY0AMIGJAoGBAKoc7n6zA+sO8NATMcfJ+U2aoDEsrj/cObG3QAN6Sr+l        ygWxYXLBZNfSDWqL1K4edLr4gCZIDFsq0PIEaYZhYRGjhbcuJ9H/ZdtWdX        xcwEWN4mwFzlsASogsh5JeqS8db3A1JWkvhO9EUfaCYk8YMAkXYdCtLD9s        9tCYZeTE2ut9AgMBAAGjgcswgcgwHQYDVR0OBBYEFHPw7VJIoIM3VYhuHa        eAwpPF5leMMIGYBgNVHSMEgZAwgY2AFHPw7VJIoIM3VYhuHaeAwpPF5leM        oXKkcDBuMQswCQYDVQQGEwJJVDEfMB0GA1UEChMWU2Vydml6aSBQb3N0YW        xpIFMuci5sLjEPMA0GA1UECxMGRC5DLkMuMS0wKwYJKoZIhvcNAQkBFh5w        b3N0YS1jZXJ0aWZpY2F0YUBzZXJwb3N0YWwuaXSCAQAwDAYDVR0TBAUwAw        EB/zANBgkqhkiG9w0BAQQFAAOBgQApqeXvmOyEjwhMrXezPAXELMZwv4qqPetrucci, et al.              Informational                    [Page 45]

RFC 6109                Certified Electronic Mail             April 2011        r5ri4XuxTq6sS9jRsEbZrS+NmbcJ7S7eFwNQMNxYFVJqdWoLh8qExsTLXn        sKycSnHbCfuphrKvXjQvR2da75U4zGSkroiyvJ2s9TtiCcT3lQtIjmvrFb        aSBiyzj+za7foFUCQmxCLtDaA==       mailReceipt: takecharge@postalser.example.com       LDIFLocationURL: https://postalser.example.com/ldif.txt.p7m       managedDomains: postal-services.example.com       managedDomains: receivedmail.example.com       description: Certified mail services for the public   The following LDIF file represents an example of a PEC providers'   directory, containing a base root and two fictitious providers, the   first of which handles a secondary environment as well.  The   certificates inserted are two self-signed certificates used for   example purposes only:       dn: o=postacert       objectclass: top       objectclass: organization       objectClass: LDIFLocationURLObject       o: postacert       LDIFLocationURL:https://igpec.rupa.example.com/igpec.ldif.p7m       description: Base root for the PEC providers directory       dn: providerName=Anonymous Certified Mail S.p.A.,o=postacert       objectclass: top       objectclass: provider       providerName: Anonymous Certified Mail S.p.A.       providerCertificateHash:        7E7AEF1059AE0F454F2643A95F69EC3556009239       providerCertificate;binary::        MIIDBjCCAm+gAwIBAgIBADANBgkqhkiG9w0BAQQFADBmMQswCQYDVQQGEw        JJVDEpMCcGA1UEChMgQW5vbmltYSBQb3N0YSBDZXJ0aWZpY2F0YSBTLnAu        QS4xLDAqBgkqhkiG9w0BCQEWHXBvc3RhLWNlcnRpZmljYXRhQGFucG9jZX        J0Lml0MB4XDTAyMTIwOTE3MjQxNVoXDTAzMTIwOTE3MjQxNVowZjELMAkG        A1UEBhMCSVQxKTAnBgNVBAoTIEFub25pbWEgUG9zdGEgQ2VydGlmaWNhdG        EgUy5wLkEuMSwwKgYJKoZIhvcNAQkBFh1wb3N0YS1jZXJ0aWZpY2F0YUBh        bnBvY2VydC5pdDCBnzANBgkqhkiG9w0BAQEFAAOBjQAwgYkCgYEAr8J+qK        KdxV9LzDMPqwnEy0P8H/KwbI0Szs8p6UZajZdpeUK0Ncbrv1QyXZNNtSMC        2uL09HDyx8agjgZWdhypnehguiSK3busha15RSpMGhiqxmz2b0HhOG73Gf        alZelqrwqmElna4MNUaLhbOvTd/sqPUS378w5IaIhWxzy34XcCAwEAAaOB        wzCBwDAdBgNVHQ4EFgQUN8lC0znQWEs0xspZ/aBzsaGvRZMwgZAGA1UdIw        SBiDCBhYAUN8lC0znQWEs0xspZ/aBzsaGvRZOhaqRoMGYxCzAJBgNVBAYT        AklUMSkwJwYDVQQKEyBBbm9uaW1hIFBvc3RhIENlcnRpZmljYXRhIFMucC        5BLjEsMCoGCSqGSIb3DQEJARYdcG9zdGEtY2VydGlmaWNhdGFAYW5wb2Nl        cnQuaXSCAQAwDAYDVR0TBAUwAwEB/zANBgkqhkiG9w0BAQQFAAOBgQA58B        Z+q1qSKpuffzTBpMtbeFkDIxMqMa+ycnxdMNvcWgCm1A9ZiFJsvqYhDDqA        XxfHjkrzXuSZkYq6WiQCsLp0aYVy40QCIwbOunhrvsxh3vsG5CgN76JzZ9Petrucci, et al.              Informational                    [Page 46]

RFC 6109                Certified Electronic Mail             April 2011        5Z/1OCFNhLfqf1VH2NSS8TaYCCi/VO7W1Q1KkcA2VlxlQP7McSUw==       mailReceipt: notifications@anpocert.it.example       LDIFLocationURL: http://anpocert.example.com/anpocert.ldif.p7m       managedDomains: mail.anpocert.example.com       managedDomains: cert.company.example.com       managedDomains: costmec.example.com       description: Certified mail services for companies       dn: providerUnit=Secondary Environment, providerName=Anonymous        Certified Mail S.p.A.,o=postacert       objectclass: top       objectclass: provider       providerName: Certified Mail S.p.A.       providerUnit: Secondary Environment       providerCertificateHash:        7E7AEF1059AE0F454F2643A95F69EC3556009239       providerCertificate;binary::        MIIDBjCCAm+gAwIBAgIBADANBgkqhkiG9w0BAQQFADBmMQswCQYDVQQGEw        JJVDEpMCcGA1UEChMgQW5vbmltYSBQb3N0YSBDZXJ0aWZpY2F0YSBTLnAu        QS4xLDAqBgkqhkiG9w0BCQEWHXBvc3RhLWNlcnRpZmljYXRhQGFucG9jZX        J0Lml0MB4XDTAyMTIwOTE3MjQxNVoXDTAzMTIwOTE3MjQxNVowZjELMAkG        A1UEBhMCSVQxKTAnBgNVBAoTIEFub25pbWEgUG9zdGEgQ2VydGlmaWNhdG        EgUy5wLkEuMSwwKgYJKoZIhvcNAQkBFh1wb3N0YS1jZXJ0aWZpY2F0YUBh        bnBvY2VydC5pdDCBnzANBgkqhkiG9w0BAQEFAAOBjQAwgYkCgYEAr8J+qK        KdxV9LzDMPqwnEy0P8H/KwbI0Szs8p6UZajZdpeUK0Ncbrv1QyXZNNtSMC        2uL09HDyx8agjgZWdhypnehguiSK3busha15RSpMGhiqxmz2b0HhOG73Gf        alZelqrwqmElna4MNUaLhbOvTd/sqPUS378w5IaIhWxzy34XcCAwEAAaOB        wzCBwDAdBgNVHQ4EFgQUN8lC0znQWEs0xspZ/aBzsaGvRZMwgZAGA1UdIw        SBiDCBhYAUN8lC0znQWEs0xspZ/aBzsaGvRZOhaqRoMGYxCzAJBgNVBAYT        AklUMSkwJwYDVQQKEyBBbm9uaW1hIFBvc3RhIENlcnRpZmljYXRhIFMucC        5BLjEsMCoGCSqGSIb3DQEJARYdcG9zdGEtY2VydGlmaWNhdGFAYW5wb2Nl        cnQuaXSCAQAwDAYDVR0TBAUwAwEB/zANBgkqhkiG9w0BAQQFAAOBgQA58B        Z+q1qSKpuffzTBpMtbeFkDIxMqMa+ycnxdMNvcWgCm1A9ZiFJsvqYhDDqA        XxfHjkrzXuSZkYq6WiQCsLp0aYVy40QCIwbOunhrvsxh3vsG5CgN76JzZ9        5Z/1OCFNhLfqf1VH2NSS8TaYCCi/VO7W1Q1KkcA2VlxlQP7McSUw==       mailReceipt: notifications@secondary.anpocert.example.com       managedDomains: management.anpocert.example.com       managedDomains: personnel.anpocert.example.com       description: Corporate internal services       dn: providerName=Postal Services S.r.l.,o=postacert       objectclass: top       objectclass: provider       providerName: Postal Services S.r.l.       providerCertificateHash:        e00fdd9d88be0e2cc766b893315caf93d5701a6a       providerCertificate;binary::        MIIDHjCCAoegAwIBAgIBADANBgkqhkiG9w0BAQQFADBuMQswCQYDVQQGEw        JJVDEfMB0GA1UEChMWU2Vydml6aSBQb3N0YWxpIFMuci5sLjEPMA0GA1UE        CxMGRC5DLkMuMS0wKwYJKoZIhvcNAQkBFh5wb3N0YS1jZXJ0aWZpY2F0YUPetrucci, et al.              Informational                    [Page 47]

RFC 6109                Certified Electronic Mail             April 2011        BzZXJwb3N0YWwuaXQwHhcNMDIxMjA5MTczMjE2WhcNMDMxMjA5MTczMjE2        WjBuMQswCQYDVQQGEwJJVDEfMB0GA1UEChMWU2Vydml6aSBQb3N0YWxpIF        Muci5sLjEPMA0GA1UECxMGRC5DLkMuMS0wKwYJKoZIhvcNAQkBFh5wb3N0        YS1jZXJ0aWZpY2F0YUBzZXJwb3N0YWwuaXQwgZ8wDQYJKoZIhvcNAQEBBQ        ADgY0AMIGJAoGBAKoc7n6zA+sO8NATMcfJ+U2aoDEsrj/cObG3QAN6Sr+l        ygWxYXLBZNfSDWqL1K4edLr4gCZIDFsq0PIEaYZhYRGjhbcuJ9H/ZdtWdX        xcwEWN4mwFzlsASogsh5JeqS8db3A1JWkvhO9EUfaCYk8YMAkXYdCtLD9s        9tCYZeTE2ut9AgMBAAGjgcswgcgwHQYDVR0OBBYEFHPw7VJIoIM3VYhuHa        eAwpPF5leMMIGYBgNVHSMEgZAwgY2AFHPw7VJIoIM3VYhuHaeAwpPF5leM        oXKkcDBuMQswCQYDVQQGEwJJVDEfMB0GA1UEChMWU2Vydml6aSBQb3N0YW        xpIFMuci5sLjEPMA0GA1UECxMGRC5DLkMuMS0wKwYJKoZIhvcNAQkBFh5w        b3N0YS1jZXJ0aWZpY2F0YUBzZXJwb3N0YWwuaXSCAQAwDAYDVR0TBAUwAw        EB/zANBgkqhkiG9w0BAQQFAAOBgQApqeXvmOyEjwhMrXezPAXELMZwv4qq        r5ri4XuxTq6sS9jRsEbZrS+NmbcJ7S7eFwNQMNxYFVJqdWoLh8qExsTLXn        sKycPSnHbCfuphrKvXjQvR2da75U4zGSkroiyvJ2s9TtiCcT3lQtIjmvrF        baSBiyzj+za7foFUCQmxCLtDaA==       mailReceipt: ssacceptance@postalser.example.com       LDIFLocationURL: http://postalser.example.com/ldif.txt.p7m       managedDomains: postal-services.example.com       managedDomains: receivedmail.example.com       description: Certified mail services for the public5.  Security-Related Aspects5.1.  Digital Signature   It is recommended that a dedicated hardware module be used to handle   private key and signature operations, the specifications of which are   outside the scope of this document.  It's up to the PEC providers to   conform to security requisites expected for the service.5.2.  Authentication   User access to PEC services through the Access Point MUST be allowed   only upon successful user authentication on the system.   For example, authentication might use user-ID and password, or, if   available and considered necessary for the type of service provided,   an electronic ID card or the national services card.  Choice of   authentication method is left to the better judgment of the service   provider.  Authentication is necessary to guarantee as much as   possible that the message is sent by a PEC user whose identification   data is congruent with the specified sender, so as to avoid   falsification of the latter.Petrucci, et al.              Informational                    [Page 48]

RFC 6109                Certified Electronic Mail             April 20115.3.  Secure Interaction   To guarantee that the original message remains unaltered during   transaction, envelopment and signature are applied on outgoing   messages at the Access Point, and subsequent verification of incoming   messages is done at the Incoming Point.   All communications within the PEC network MUST use secure channels.   Integrity and confidentiality of connections between PEC provider and   user MUST be guaranteed through the use of secure protocols, such as   those based on [TLS] and those that create a secure transport channel   on which non-secure protocols can transmit (e.g., IPsec).   The interaction between providers MUST take place using SMTP on   [TLS], as per [SMTP-TLS].  The Incoming Point MUST provide and   announce its support for the STARTTLS extension, as well as accept   both unencrypted connections (for ordinary mail) and protected ones.   To guarantee complete traceability in the flow of PEC messages, these   MUST NOT transit on systems external to the PEC network.  When   exchanging messages between different providers, all transactions   MUST take place between machines that belong to the PEC network or   are directly managed by the provider.  An "MX" type record MAY be   associated to each PEC domain defined within the system for name   resolution, in which case secondary reception systems specified in   that record MUST be under direct control of the provider.  All in   conformance with [SMTP].5.4.  Virus   Another important security aspect that concerns the PEC system, is   related to the technical and functional architecture that MUST block   the presence of viruses from endangering the security of all handled   messages.  It is therefore REQUIRED to have installations and   continuous updates of anti-virus systems that hinder infections as   much as possible without intervening on the content of the certified   mail, in compliance with what has been discussed thus far.5.5.  S/MIME Certificate   In this document the S/MIME certificate profile is defined for use in   the certification of PEC messages done by the providers.  The   proposed profile of the S/MIME certificate is based on the IETF   standards [SMIMECERT] and [CRL], which in turn are based on the   standard ISO/IEC 9594-8:2001.Petrucci, et al.              Informational                    [Page 49]

RFC 6109                Certified Electronic Mail             April 20115.5.1.  Provider-Related Information (Subject)   The information related to the PEC provider holder of the certificate   MUST be inserted in the Subject field (Subject DN).  More precisely,   the Subject DN MUST contain the PEC provider's name as it is in the   "providerName" attribute published in the PEC providers directory   (section 4.5), but the Subject DN does not have to match the Provider   entry DN in the LDIF.  The providerName MUST be present in the   CommonName or OrganizationName attributes of the "Subject:" field in   the certificate.   Certificates MUST contain an Internet mail address, which MUST have a   value in the subjectAltName extension, and SHOULD NOT be present in   the Subject Distinguished Name.   Valid subjectDN are:        C=IT, O=AcmePEC S.p.A, CN=Posta Certificata        C=IT, O=ServiziPEC S.p.A, CN=Posta Certificata   Valorization of other attributes in the Subject DN, if present, MUST   be done in compliance with [CRL].5.5.2.  Certificate Extensions   Extensions that MUST be present in the S/MIME certificate are:   o  Key Usage   o  Authority Key Identifier   o  Subject Key Identifier   o  Subject Alternative Name   The Basic Constraints extension (Object ID:2.5.29.19) MUST NOT be   present.   The valorization of the above listed extensions for the described   profile follows.   The Key Usage extension (Object ID: 2.5.29.15) MUST have the   digitalSignature bit (bit 0) activated and MUST be marked as   critical.  The extension MAY contain other active bits corresponding   to different Key Usage, as long as that doesn't contrast with the   indications in [CRL].Petrucci, et al.              Informational                    [Page 50]

RFC 6109                Certified Electronic Mail             April 2011   The Authority Key Identifier (Object ID: 2.5.29.35) MUST contain at   least the keyIdentifier field and MUST NOT be marked as critical.   The Subject Key Identifier extension (Object ID: 2.5.29.14) MUST   contain at least the keyIdentifier field and MUST NOT be marked as   critical.   The Subject Alternative Name (Object ID: 2.5.29.17) MUST contain at   least the rfc822Name field and MUST NOT be marked as critical.   Adding other extensions that have not been described in this document   is to be considered OPTIONAL, as long as it remains compliant with   [CRL]; such added extensions MUST NOT be marked as critical.5.5.3.  Example   Following is an example of an S/MIME certificate compliant with the   minimal requisites described in this profile.  Values used are of   fictitious providers generated for example purposes only.5.5.3.1.  General-Use Certificate in Annotated Version   An asterisk near the label of an extension means that such an   extension has been marked as critical.       VERSION: 3       SERIAL: 11226 (0x2bda)       INNER SIGNATURE:         ALG. ID: id-sha1-with-rsa-encryption         PARAMETER: 0       ISSUER:         Country Name: IT         Organization Name: Certifier 1         Organizational Unit Name: Certification Service Provider         Common Name: Certifier S.p.A.       VALIDITY:         Not Before: Oct 5, 04 09:04:23 GMT         Not After: Oct 5, 05 09:04:23 GMT       SUBJECT:         Country Name: IT         Organization Name: AcmePEC S.p.A.         Common Name: Certified Mail       PUBLIC KEY: (key size is 1024 bits)       ALGORITHM:         ALG. ID: id-rsa-encryption         PARAMETER: 0       MODULUS: 0x00afbeb4 5563198a aa9bac3f 1b29b5be                7f691945 89d01569 ca0d555b 5c33d7e9Petrucci, et al.              Informational                    [Page 51]

RFC 6109                Certified Electronic Mail             April 2011                ...                d15ff128 6792def5 b3f884e6 54b326db                cf       EXPONENT: 0x010001       EXTENSIONS:         Subject Alt Name:         RFC Name: posta-certificata@acmepec.it         Key Usage*: Digital Signature         Authority Key Identifier: 0x12345678 aaaaaaaa bbbbbbbb                                   cccccccc dddddddd         Subject Key Identifier: 0x3afae080 6453527a 3e5709d8 49a941a8                                 a3a70ae1       SIGNATURE:         ALG. ID: id-sha1-with-rsa-encryption         PARAMETER: 0         VALUE: 0x874b4d25 70a46180 c9770a85 fe7923ce                b22d2955 2f3af207 142b2aba 643aaa61                ...                d8fd10b4 c9e00ebc c089f7a3 549a1907                ff885220 ce796328 b0f8ecac 86ffb1cc5.5.3.2.  General-Use Certificate in Dump ASN.1   0 30  794: SEQUENCE {   4 30  514:  SEQUENCE {   8 A0   3:   [0] {   10 02  1:    INTEGER 2       :      }   13 02  2:   INTEGER 11226   17 30   13:  SEQUENCE {   19 06  9:    OBJECT IDENTIFIER         :      sha1withRSAEncryption (1 2 840 113549 1 1 5)   30 05  0:    NULL         :    }   32 30  101:  SEQUENCE {   34 31   11:   SET {   36 30   9:     SEQUENCE {   38 06   3:      OBJECT IDENTIFIER countryName (2 5 4 6)   43 13   2:      PrintableString 'IT'         :      }         :    }   47 31   28:   SET {   49 30   26:    SEQUENCE {   51 06   3:      OBJECT IDENTIFIER organizationName (2 5 4 10)   56 13   19:     PrintableString 'Certificatore 1'         :      }         :    }   77 31   22:   SET {Petrucci, et al.              Informational                    [Page 52]

RFC 6109                Certified Electronic Mail             April 2011   79 30   20:    SEQUENCE {   81 06   3:   OBJECT IDENTIFIER organizationalUnitName (2 5 4 11)   86 13   13:    PrintableString 'Certification Service Provider'         :      }         :    }   101 31  32:   SET {   103 30  30:    SEQUENCE {   105 06  3:      OBJECT IDENTIFIER commonName (2 5 4 3)   110 13  23:     PrintableString 'Certificatore S.p.A.'         :      }         :    }         :  }   135 30  30:  SEQUENCE {   137 17  13:   UTCTime '041005090423Z'   152 17  13:   UTCTime '051005090423Z'         :     }   167 30  66:  SEQUENCE {   169 31  11:   SET {   171 30  9:     SEQUENCE {   173 06  3:      OBJECT IDENTIFIER countryName (2 5 4 6)   178 13  2:      PrintableString 'IT'         :      }         :    }   182 31  23:  SET {   184 30  21:   SEQUENCE {   186 06  3:     OBJECT IDENTIFIER organizationName (2 5 4 10)   191 13  14:    PrintableString 'AcmePEC S.p.A.'         :      }         :    }   207 31  26:  SET {   209 30  24:   SEQUENCE {   211 06  3:     OBJECT IDENTIFIER commonName (2 5 4 3)   216 13  17:    PrintableString 'Posta Certificata'         :      }         :    }         :  }   235 30  159: SEQUENCE {   238 30  13:   SEQUENCE {   240 06  9:     OBJECT IDENTIFIER rsaEncryption (1 2 840 113549                  1 1 1)   251 05  0:     NULL         :      }   253 03  141:  BIT STRING 0 unused bits         :     30 81 89 02 81 81 00 AF BE B4 55 63 19 8A AA 9B         :     AC 3F 1B 29 B5 BE 7F 69 19 45 89 D0 15 69 CA 0D         :     55 5B 5C 33 D7 E9 C8 6E FC 14 46 C3 C3 09 47 DD         :     CD 10 74 1D 76 4E 71 14 E7 69 42 BE 1C 47 61 85         :     4D 74 76 DD 0B B5 78 4F 1E 84 DD B4 86 7F 96 DFPetrucci, et al.              Informational                    [Page 53]

RFC 6109                Certified Electronic Mail             April 2011         :     5E 7B AF 0E CE EA 12 57 0B DF 9B 63 67 4D F9 37         :     B7 48 35 27 C2 89 F3 C3 54 66 F7 DA 6C BE 4F 5D         :     85 55 07 A4 97 8C D1 5F F1 28 67 92 DE F5 B3 F8         :         [ Another 12 bytes skipped ]         :    }   397 A3  123: [3] {   399 30  121:  SEQUENCE {   401 30  39:    SEQUENCE {   403 06  3:      OBJECT IDENTIFIER subjectAltName (2 5 29 17)   408 04  32:     OCTET STRING         :      30 1E 81 1C 70 6F 73 74 61 2D 63 65 72 74 69 66         :      69 63 61 74 61 40 61 63 6D 65 70 65 63 2E 69 74         :     }   442 30  14:   SEQUENCE {   444 06  3:     OBJECT IDENTIFIER keyUsage (2 5 29 15)   449 01  1:     BOOLEAN TRUE   452 04  4:     OCTET STRING         :      03 02 07 80         :      }   458 30  31:   SEQUENCE {   460 06  3:  OBJECT IDENTIFIER authorityKeyIdentifier (2 5 29 35)   465 04  24:    OCTET STRING         :     30 16 11 11 11 11 AA AA AA AA AA BB BB BB BB CC CC         :     CC CC DD DD DD DD         :      }   491 30  29:   SEQUENCE {   493 06  3:    OBJECT IDENTIFIER subjectKeyIdentifier (2 5 29 14)   498 04  22:    OCTET STRING         :      04 14 3A FA E0 80 64 53 52 7A 3E 57 09 D8 49 A9         :      41 A8 A3 A7 0A E1         :      }         :     }         :    }         :   }   522 30  13: SEQUENCE {   524 06  9:   OBJECT IDENTIFIER         :      sha1withRSAEncryption (1 2 840 113549 1 1 5)   535 05  0:   NULL         :    }   537 03  257: BIT STRING 0 unused bits         :     87 4B 4D 25 70 A4 61 80 C9 77 0A 85 FE 79 23 CE         :     B2 2D 29 55 2F 3A F2 07 14 2B 2A BA 64 3A AA 61         :     1F F0 E7 3F C4 E6 13 E2 09 3D F0 E1 83 A0 C0 F2         :     C6 71 7F 3A 1C 80 7F 15 B3 D6 1E 22 79 B8 AC 91         :     51 83 F2 3A 84 86 B6 07 2B 22 E8 01 52 2D A4 50         :     9F C6 42 D4 7C 38 B1 DD 88 CD FC E8 C3 12 C3 62         :     64 0F 16 BF 70 15 BC 01 16 78 30 2A DA FA F3 70         :     E2 D3 0F 00 B0 FD 92 11 6C 55 45 48 F5 64 ED 98Petrucci, et al.              Informational                    [Page 54]

RFC 6109                Certified Electronic Mail             April 2011         :         [ Another 128 bytes skipped ]         : }5.6.  PEC Providers Directory   The contents of the PEC providers directory MUST be queried via   [HTTP] on a Secure Socket Layer (SSL), as described in [TLS],   exclusively by licensed providers that have the necessary user   certificates; this access modality guarantees authenticity,   integrity, and confidentiality of data.  Each provider downloads the   LDIF file through an [HTTPS] session, which is authenticated by   checking the X.509 certificate issued by a certification authority.6.  PEC System Client Technical and Functional Prerequisites   This section lists the prerequisites that must be respected by a   client in order to guarantee the minimal operative functionalities to   the user of a general PEC system:   o  handling of Access and Delivery Points through secure channels;   o  handling of user authentication in message dispatch and reception      which make use of standard protocols, such as [IMAP], [POP3], and      [HTTP];   o  support for MIME format according to [MIME1] and [MIME5];   o  support for "ISO-8859-1 (Latin-1)" character set;   o  support for S/MIME v3 standard, as in [SMIMEV3], for verification      of signatures applied to PEC envelopes and notifications.7.  Security Considerations   All security considerations from [CMS] and [SMIMEV3] apply to   applications that use procedures described in this document.   The centralized LDAP server is a critical point for the security of   the whole PEC system.  An attack could compromise the whole PEC   system.  PEC providers that periodically download the LDIF file   SHOULD use the best security technology to protect it from local   attacks.  A PEC provider could be compromised if an attacker changed   a certificate or modified the list of domains associated to it in the   LDIF file that was copied to the PEC provider system.Petrucci, et al.              Informational                    [Page 55]

RFC 6109                Certified Electronic Mail             April 2011   When verifying the validity of the signature of a message, the   recipient system SHOULD verify that the certificate included in the   [CMS] message is present in the LDIF file (section 4.5) and that the   domain extracted by the [EMAIL] "From:" header is listed in the   managedDomains attribute associated to said certificate.8.  IANA Considerations8.1.  Registration of PEC Message Header Fields   This document defines new header fields used in the messages that   transit in the PEC network.  As specified and required by   [HEADERS-IANA], this document registers new header fields as   Provisional Message Header Fields as follows.8.1.1.  Header Field: X-Riferimento-Message-ID:   Applicable protocol: mail [EMAIL]   Status: provisional   Author/Change controller:      Claudio Petrucci      DigitPA      Viale Carlo Marx 31/49      00137 Roma      Italy      EMail: PETRUCCI@digitpa.gov.it   Specification document: this document,section 2.2.1,Appendix A.8.1.2.  Header Field: X-Ricevuta:   Applicable protocol: mail [EMAIL]   Status: provisional   Author/Change controller:      Claudio Petrucci      DigitPA      Viale Carlo Marx 31/49      00137 Roma      Italy      EMail: PETRUCCI@digitpa.gov.itPetrucci, et al.              Informational                    [Page 56]

RFC 6109                Certified Electronic Mail             April 2011   Specification document: this document, sections2.1.1.1.1,3.1.2,                           3.1.3, 3.1.4, 3.1.6, 3.2.1, 3.2.3, 3.2.4,                           3.3.2, 3.3.3,Appendix A.8.1.3.  Header Field: X-VerificaSicurezza:   Applicable protocol: mail [EMAIL]   Status: provisional   Author/Change controller:      Claudio Petrucci      DigitPA      Viale Carlo Marx 31/49      00137 Roma      Italy      EMail: PETRUCCI@digitpa.gov.it   Specification document: this document, sections2.1.1.1.3,3.1.3,                           3.2.4,Appendix A.8.1.4.  Header Field: X-Trasporto:   Applicable protocol: mail [EMAIL]   Status: provisional   Author/Change controller:      Claudio Petrucci      DigitPA      Viale Carlo Marx 31/49      00137 Roma      Italy      EMail: PETRUCCI@digitpa.gov.it   Specification document: this document, sections3.1.5,3.2.2,Appendix A.8.1.5.  Header Field: X-TipoRicevuta:   Applicable protocol: mail [EMAIL]   Status: provisionalPetrucci, et al.              Informational                    [Page 57]

RFC 6109                Certified Electronic Mail             April 2011   Author/Change controller:      Claudio Petrucci      DigitPA      Viale Carlo Marx 31/49      00137 Roma      Italy      EMail: PETRUCCI@digitpa.gov.it   Specification document: this document, sections3.1.5,3.3.2,                           3.3.2.1, 3.3.2.2, 3.3.2.3,Appendix A.8.1.6.  Header Field: X-Mittente:   Applicable protocol: mail [EMAIL]   Status: provisional   Author/Change controller:      Claudio Petrucci      DigitPA      Viale Carlo Marx 31/49      00137 Roma      Italy      EMail: PETRUCCI@digitpa.gov.it   Specification document: this document, sections3.2.3,Appendix A.8.2.  Registration of LDAP Object Identifier Descriptors   This document defines new LDAP attributes and object classes for   object identifier descriptors.  As specified and required by   [LDAP-IANA], this document registers new descriptors as follows per   the Expert Review.8.2.1.  Registration of Object Classes and Attribute Types   Subject: Request for LDAP Descriptor Registration   Descriptor (short name): See comments   Object Identifier: See comments   Person & email address to contact for further information:      See "Author/Change Controller"   Usage: See commentsPetrucci, et al.              Informational                    [Page 58]

RFC 6109                Certified Electronic Mail             April 2011   Specification: (I-D)   Author/Change Controller:      Claudio Petrucci      DigitPA      Viale Carlo Marx 31/49      00137 Roma      Italy      EMail: PETRUCCI@digitpa.gov.it   Comments:      The following object identifiers and associated object classes/      attribute types are requested to be registered.   OID                         Descriptor              Usage   ------------------------    ---------------------   ------   1.3.6.1.4.1.16572.2.1.1     LDIFLocationURLObject      O   1.3.6.1.4.1.16572.2.1.2     provider                   O   1.3.6.1.4.1.16572.2.2.1     providerCertificateHash    A   1.3.6.1.4.1.16572.2.2.2     providerCertificate        A   1.3.6.1.4.1.16572.2.2.3     providerName               A   1.3.6.1.4.1.16572.2.2.4     mailReceipt                A   1.3.6.1.4.1.16572.2.2.5     managedDomains             A   1.3.6.1.4.1.16572.2.2.6     LDIFLocationURL            A   1.3.6.1.4.1.16572.2.2.7     providerUnit               A   Legend   -------------------   O => Object Class   A => Attribute Type9.  References9.1.  Normative References   [ABNF]          Crocker, D., Ed., and P. Overell, "Augmented BNF for                   Syntax Specifications: ABNF", STD 68,RFC 5234,                   January 2008.   [CMS]           Housley, R., "Cryptographic Message Syntax (CMS)",                   STD 70,RFC 5652, September 2009.   [CRL]           Cooper, D., Santesson, S., Farrell, S., Boeyen, S.,                   Housley, R., and W. Polk, "Internet X.509 Public Key                   Infrastructure Certificate and Certificate Revocation                   List (CRL) Profile",RFC 5280, May 2008.Petrucci, et al.              Informational                    [Page 59]

RFC 6109                Certified Electronic Mail             April 2011   [EMAIL]         Resnick, P., Ed., "Internet Message Format",RFC5322, October 2008.   [HEADERS-IANA]  Klyne, G., Nottingham, M., and J. Mogul,                   "Registration Procedures for Message Header Fields",BCP 90,RFC 3864, September 2004.   [HTTP]          Fielding, R., Gettys, J., Mogul, J., Frystyk, H.,                   Masinter, L., Leach, P., and T. Berners-Lee,                   "Hypertext Transfer Protocol -- HTTP/1.1",RFC 2616,                   June 1999.   [HTTPS]         Rescorla, E., "HTTP Over TLS",RFC 2818, May 2000.   [IMAP]          Crispin, M., "INTERNET MESSAGE ACCESS PROTOCOL -                   VERSION 4rev1",RFC 3501, March 2003.   [LDAP]          Zeilenga, K., Ed., "Lightweight Directory Access                   Protocol (LDAP): Technical Specification Road Map",RFC 4510, June 2006.   [LDAP-IANA]     Zeilenga, K., "Internet Assigned Numbers Authority                   (IANA) Considerations for the Lightweight Directory                   Access Protocol (LDAP)",BCP 64,RFC 4520, June 2006.   [LDAP-SYNTAXES] Legg, S., Ed., "Lightweight Directory Access Protocol                   (LDAP): Syntaxes and Matching Rules",RFC 4517, June                   2006.   [LDIF]          Good, G., "The LDAP Data Interchange Format (LDIF) -                   Technical Specification",RFC 2849, June 2000.   [MIME1]         Freed, N. and N. Borenstein, "Multipurpose Internet                   Mail Extensions (MIME) Part One: Format of Internet                   Message Bodies",RFC 2045, November 1996.   [MIME5]         Freed, N. and N. Borenstein, "Multipurpose Internet                   Mail Extensions (MIME) Part Five: Conformance                   Criteria and Examples",RFC 2049, November 1996.   [SUBMISSION]    Gellens, R. and J. Klensin, "Message Submission for                   Mail",RFC 4409, April 2006.   [POP3]          Myers, J. and M. Rose, "Post Office Protocol -                   Version 3", STD 53,RFC 1939, May 1996.Petrucci, et al.              Informational                    [Page 60]

RFC 6109                Certified Electronic Mail             April 2011   [REQ]           Bradner, S., "Key words for use in RFCs to Indicate                   Requirement Levels",BCP 14,RFC 2119, March 1997.   [SHA1]          Eastlake 3rd, D. and P. Jones, "US Secure Hash                   Algorithm 1 (SHA1)",RFC 3174, September 2001.   [MIME-SECURE]   Galvin, J., Murphy, S., Crocker, S., and N. Freed,                   "Security Multiparts for MIME: Multipart/Signed and                   Multipart/Encrypted",RFC 1847, October 1995.   [SMIMEV3]       Ramsdell, B. and S. Turner, "Secure/Multipurpose                   Internet Mail Extensions (S/MIME) Version 3.2 Message                   Specification",RFC 5751, January 2010.   [SMIMECERT]     Ramsdell, B. and S. Turner, "Secure/Multipurpose                   Internet Mail Extensions (S/MIME) Version 3.2                   Certificate Handling",RFC 5750, January 2010.   [SMTP]          Klensin, J., "Simple Mail Transfer Protocol",RFC5321, October 2008.   [SMTP-DSN]      Moore, K., "Simple Mail Transfer Protocol (SMTP)                   Service Extension for Delivery Status Notifications                   (DSNs)",RFC 3461, January 2003.   [SMTP-TLS]      Hoffman, P., "SMTP Service Extension for Secure SMTP                   over Transport Layer Security",RFC 3207, February                   2002.   [TIMESTAMP]     Klyne, G. and C. Newman, "Date and Time on the                   Internet: Timestamps",RFC 3339, July 2002.   [TLS]           Dierks, T. and E. Rescorla, "The Transport Layer                   Security (TLS) Protocol Version 1.2",RFC 5246,                   August 2008.   [XML]           W3C, "Extensible Markup Language (XML) 1.0 (Fifth                   Edition)", W3C Recommendation, November 2008,                   <http://www.w3.org/TR/2006/REC-xml-20060816/>.9.2. Informative References   [RFC1034]       Mockapetris, P., "Domain names - concepts and                   facilities", STD 13,RFC 1034, November 1987.Petrucci, et al.              Informational                    [Page 61]

RFC 6109                Certified Electronic Mail             April 2011   [RFC4522]       Legg, S., "Lightweight Directory Access Protocol                   (LDAP): The Binary Encoding Option",RFC 4522, June                   2006.   [RFC4523]      Zeilenga, K., "Lightweight Directory Access Protocol                   (LDAP) Schema Definitions for X.509 Certificates",RFC 4523, June 2006.10.  Acknowledgments   The Italian document on which this document is based, is a product of   the collaboration of many with the supervision of the National Center   for Informatics in the Public Administration of Italy (DigitPA).Petrucci, et al.              Informational                    [Page 62]

RFC 6109                Certified Electronic Mail             April 2011Appendix A.  Italian Fields and Values in English   NOTE: The right column represents a translation of the Italian fields         for readability's sake only.  Header fields that MUST be used         are the ones in the left column.    X-Riferimento-Message-ID        Reference Message Identifier    X-Ricevuta                      Notification      non-accettazione                non acceptance      accettazione                    server-user acceptance      preavviso-errore-consegna       delivery error advance notice      presa-in-carico                 server-server acceptance      rilevazione-virus               virus detection      errore-consegna                 delivery error      avvenuta-consegna               message delivered    X-Mittente                      Sender    X-VerificaSicurezza             Security Verification      errore                          error    X-Trasporto                     Transport      posta-certificata               certified mail      errore                          error    X-TipoRicevuta                  Notification Type      completa                        complete      breve                           brief      sintetica                       concise    certificatore                   certificator    Subject values:      Accettazione                   SERVER-USER ACCEPTANCE      Posta certificata              CERTIFIED MAIL      Presa in carico                SERVER-SERVER ACCEPTANCE      Consegna                       DELIVERY      Anomalia messaggio             MESSAGE ANOMALY      Problema di sicurezza          SECURITY PROBLEM      Avviso di non accettazione     NON ACCEPTANCE PEC NOTIFICATION      Avviso di non accettazione     VIRUS DETECTION INDUCED NON      per virus                      ACCEPTANCE PEC NOTIFICATION      Avviso di mancata consegna     NON DELIVERY PEC NOTIFICATION      Avviso di mancata consegna     NON DELIVERY DUE TO VIRUS PEC      per virus                      NOTIFICATION      Avviso di mancata consegna     NON DELIVERY DUE TO TIMEOUT PEC      per sup. tempo massimo         NOTIFICATIONPetrucci, et al.              Informational                    [Page 63]

RFC 6109                Certified Electronic Mail             April 2011   Italian terms in the DTD relative to the certification XML file:      accettazione                   server-user acceptance      altro                          other      avvenuta-consegna              delivered      certificato                    certificate      consegna                       delivery      data                           date      dati                           data      destinatari                    recipients      esterno                        external      errore                         error      errore-consegna                delivery error      errore-esteso                  extensive error      gestore-emittente              transmitting provider      giorno                         day      identificativo                 identifier      intestazione                   header      mittente                       sender      no-dest(inatario)              no recipient      no-dominio                     no domain      non-accettazione               non acceptance      nessuno                        none      oggetto                        subject      ora                            hour      posta-certificata              certified mail      preavviso-errore-consegna      delivery error advance notice      presa-in-carico                server-server acceptance      ricevuta                       notification      ricezione                      receipt (the act of receiving)      rilevazione-virus              virus detection      risposte                       replies      tipo                           typePetrucci, et al.              Informational                    [Page 64]

RFC 6109                Certified Electronic Mail             April 2011Authors' Addresses   Claudio Petrucci   DigitPA   Viale Marx 31/49   00137 Roma   Italy   EMail: petrucci@digitpa.gov.it   Francesco Gennai   ISTI-CNR   Via Moruzzi, 1   56126 Pisa   Italy   EMail: francesco.gennai@isti.cnr.it   Alba Shahin   ISTI-CNR   Via Moruzzi, 1   56126 Pisa   Italy   EMail: alba.shahin@isti.cnr.it   Alessandro Vinciarelli   Via delle Vigne di Morena 113   00118 Roma   Italy   EMail: alessandro.vinciarelli@gmail.comPetrucci, et al.              Informational                    [Page 65]

[8]ページ先頭

©2009-2025 Movatter.jp