Movatterモバイル変換


[0]ホーム

URL:


[RFC Home] [TEXT|PDF|HTML] [Tracker] [IPR] [Info page]

INFORMATIONAL
Network Working Group                                         A. SurteesRequest for Comments: 4464                                       M. WestCategory: Informational                      Siemens/Roke Manor Research                                                                May 2006Signaling Compression (SigComp) Users' GuideStatus of This Memo   This memo provides information for the Internet community.  It does   not specify an Internet standard of any kind.  Distribution of this   memo is unlimited.Copyright Notice   Copyright (C) The Internet Society (2006).Abstract   This document provides an informational guide for users of the   Signaling Compression (SigComp) protocol.  The aim of the document is   to assist users when making SigComp implementation decisions, for   example, the choice of compression algorithm and the level of   robustness against lost or misordered packets.Surtees & West               Informational                      [Page 1]

RFC 4464                  SigComp Users' Guide                  May 2006Table of Contents1. Introduction ....................................................32. Overview of the User Guide ......................................33. UDVM Assembly Language ..........................................43.1. Lexical Level ..............................................43.2. Syntactic Level ............................................53.2.1. Expressions .........................................73.2.2. Instructions ........................................83.2.3. Directives ..........................................93.2.4. Labels .............................................103.3. Uploading the Bytecode to the UDVM ........................114. Compression Algorithms .........................................124.1. Well-known Compression Algorithms .........................124.1.1. LZ77 ...............................................124.1.2. LZSS ...............................................164.1.3. LZW ................................................184.1.4. DEFLATE ............................................214.1.5. LZJH ...............................................244.2. Adapted Algorithms ........................................284.2.1. Modified DEFLATE ...................................285. Additional SigComp Mechanisms ..................................315.1. Acknowledging a State Item ................................325.2. Static Dictionary .........................................335.3. CRC Checksum ..............................................345.4. Announcing Additional Resources ...........................355.5. Shared Compression ........................................376. Security Considerations ........................................387. Acknowledgements ...............................................388. Intellectual Property Right Considerations .....................389. Informative References .........................................38Appendix A. UDVM Bytecode for the Compression Algorithms ..........40A.1. Well-known Algorithms .....................................40A.1.1.  LZ77 ..............................................40A.1.2.  LZSS ..............................................40A.1.3.  LZW ...............................................40A.1.4.  DEFLATE ...........................................40A.1.5.  LZJH ..............................................41A.2. Adapted Algorithms ........................................41A.2.1. Modified DEFLATE ...................................41Surtees & West               Informational                      [Page 2]

RFC 4464                  SigComp Users' Guide                  May 20061.  Introduction   This document provides an informational guide for users of the   SigComp protocol,RFC 3320 [2].  The idea behind SigComp is to   standardize a Universal Decompressor Virtual Machine (UDVM) that can   be programmed to understand the output of many well-known compressors   including DEFLATE [8] and LZW [7].  The bytecode for the chosen   compression algorithm is uploaded to the UDVM as part of the   compressed data.   The basic SigComp RFC describes the actions that an endpoint must   take upon receiving a SigComp message.  However, the entity   responsible for generating new SigComp messages (the SigComp   compressor) is left as an implementation decision; any compressor can   be used provided that it generates SigComp messages that can be   successfully decompressed by the receiving endpoint.   This document gives examples of a number of different compressors   that can be used by the SigComp protocol.  It also gives examples of   how to use some of the mechanisms (such as acknowledgements)   described inRFC 3321 [3].2.  Overview of the User Guide   When implementing a SigComp compressor, the first step is to choose a   compression algorithm that can encode the application messages into a   (hopefully) smaller form.  Since SigComp can upload bytecode for new   algorithms to the receiving endpoint, arbitrary compression   algorithms can be supported provided that suitable bytecode has been   written for the corresponding decompressor.   This document provides example bytecode for the following algorithms:   1.  LZ77   2.  LZSS   3.  LZW   4.  DEFLATE   5.  LZJH   Any of the above algorithms may be useful depending on the desired   compression ratio, processing and memory requirements, code size,   implementation complexity, and Intellectual Property (IPR)   considerations.   As well as encoding the application messages using the chosen   algorithm, the SigComp compressor is responsible for ensuring that   messages can be correctly decompressed even if packets are lost or   misordered during transmission.  The SigComp feedback mechanism canSurtees & West               Informational                      [Page 3]

RFC 4464                  SigComp Users' Guide                  May 2006   be used to acknowledge successful decompression at the remote   endpoint.   The following robustness techniques and other mechanisms specific to   the SigComp environment are covered in this document:   1.  Acknowledgements using the SigComp feedback mechanism   2.  Static dictionary   3.  Cyclic redundancy code (CRC) checksum   4.  Announcing additional resources   5.  Shared compression   Any or all of the above mechanisms can be implemented in conjunction   with the chosen compression algorithm.  An example subroutine of UDVM   bytecode is provided for each of the mechanisms; these subroutines   can be added to the bytecode for one of the basic compression   algorithms.  (Note: The subroutine or the basic algorithm may require   minor modification to ensure they work together correctly.)3.  UDVM Assembly Language   Writing UDVM programs directly in bytecode would be a daunting task,   so a simple assembly language is provided to facilitate the creation   of new decompression algorithms.  The assembly language includes   mnemonic codes for each of the UDVM instructions, as well as simple   directives for evaluating integer expressions, padding the bytecode,   and so forth.   The syntax of the UDVM assembly language uses the customary two-level   description technique, partitioning the grammar into a lexical and a   syntactic level.3.1.  Lexical Level   On a lexical level, a string of assembly consists of zero or more   tokens optionally separated by whitespace.  Each token can be a text   name, an instruction opcode, a delimiter, or an integer (specified as   decimal, binary, or hex).Surtees & West               Informational                      [Page 4]

RFC 4464                  SigComp Users' Guide                  May 2006   The following ABNF description,RFC 4234 [1], specifies the syntax of   a token:   token            =     (name / opcode / delimiter / dec / bin / hex)   name             =     (lowercase / "_") 0*(lowercase / digit / "_")   opcode           =     uppercase *(uppercase / digit / "-")   delimiter        =     "." / "," / "!" / "$" / ":" / "(" / ")" /                          operator   dec              =     1*(digit)   bin              =     "0b" 1*("0" / "1")   hex              =     "0x" 1*(hex-digit)   hex-digit        =     digit / %x41-46 / %x61-66   digit            =     %x30-39   uppercase        =     %x41-5a   lowercase        =     %x61-7a   operator         =     "+" / "-" / "*" / "/" / "%" / "&" / "|" /                          "^" / "~" / "<<" / ">>"   When parsing for tokens, the longest match is applied, i.e., a token   is the longest string that matches the <token> rule specified above.   The syntax of whitespace and comments is specified by the following   ABNF:   ws               =     *(%x09 / %x0a / %x0d / %x20 / comment)   comment          =     ";" *(%x00-09 / %x0b-0c / %x0e-ff)                          (%x0a / %x0d)   Whitespace that matches <ws> is skipped between tokens, but serves to   terminate the longest match for a token.   Comments are specified by the symbol ";" and are terminated by the   end of the line, for example:   LOAD (temp, 1) ; This is a comment.   Any other input is a syntax error.   When parsing on the lexical level, the string of assembly should be   divided up into a list of successive tokens.  The whitespace and   comments should also be deleted.  The assembly should then be parsed   on the syntactic level as explained inSection 3.2.3.2.  Syntactic Level   Once the string of assembly has been divided into tokens as perSection 3.1, the next step is to convert the assembly into a string   of UDVM bytecode.Surtees & West               Informational                      [Page 5]

RFC 4464                  SigComp Users' Guide                  May 2006   On a syntactic level, a string of assembly consists of zero or more   instructions, directives, or labels, each of which is itself built up   from one or more lexical tokens.   The following ABNF description specifies the syntax of the assembly   language.  Note that the lexical parsing step is assumed to have been   carried out; so in particular, the boundaries between tokens are   already known, and the comments and whitespace have been deleted:   assembly          =    *(instruction / directive / label)   instruction       =    opcode ["(" operand *("," operand) ")"]   operand           =    [["$"] expression]                              ; Operands can be left blank if they can                              ; be automatically inferred by the                              ; compiler, e.g., a literal operand                              ; that specifies the total number of                              ; operands for the instruction.                              ; When "$" is prepended to an operand,                              ; the corresponding integer is an                              ; address rather than the actual operand                              ; value.  This symbol is mandatory for                              ; reference operands, optional for                              ; multitypes and addresses, and                              ; disallowed for literals.   label             =    ":" name   directive         =    padding / data / set / readonly /                          unknown-directive   unknown-directive =    name ["(" expression *("," expression) ")"]                              ; The parser can ignore unknown                              ; directives.  The resulting bytecode                              ; may or may not generate the expected                              ; results.   padding           =    ("pad" / "align" / "at") "(" expression ")"   data              =    ("byte" / "word") "(" expression *(","                          expression) ")"   readonly          =    "readonly" "(" "0" / "1" ")"   set               =    "set" "(" name "," expression ")"   expression        =    value / "(" expression operator expression ")"   value             =    dec / bin / hex / name / "." / "!"                              ; "." is the location of this                              ; instruction/directive, whereas "!" is                              ; the location of the closest                              ; DECOMPRESSION-FAILURE   The following sections define how to convert the instructions, labels   and directives into UDVM bytecode:Surtees & West               Informational                      [Page 6]

RFC 4464                  SigComp Users' Guide                  May 20063.2.1.  Expressions   The operand values needed by particular instructions or directives   can be given in the form of expressions.  An expression can include   one or more values specified as decimal, binary, or hex (binary   values are preceded by "0b" and hex values are preceded by "0x").   The expression may also include one or more of the following   operators:          "+"    Addition          "-"    Subtraction          "*"    Multiplication          "/"    Integer division          "%"    Modulo arithmetic (a%b := a modulo b)          "&"    Binary AND          "|"    Binary OR          "^"    Binary XOR          "~"    Binary XNOR          "<<"   Binary LSHIFT          ">>"   Binary RSHIFT   The operands for each operator must always be surrounded by   parentheses so that the order in which the operators should be   evaluated is clear.  For example:   ((1 + (2 * 3)) & (0xabcd - 0b00101010)) gives the result 3.   Expressions can also include the special values "." and "!".  When   the symbol "." is encountered, it is replaced by the location in the   bytecode of the current instruction/directive.  When the symbol "!"   is encountered it is replaced by the location in the bytecode of the   closest DECOMPRESSION-FAILURE instruction (i.e., the closest zero   byte).  This can be useful when writing UDVM instructions that call a   decompression failure, for example:   INPUT-BYTES (1, temp, !)   The above instruction causes a decompression failure to occur if it   tries to input data from beyond the end of the compressed message.   Note: When using "!" in the assembly language to generate bytecode,   care must be taken to ensure that the address of the zero used at   bytecode generation time will still contain zero when the bytecode is   run.  The readonly directive (seeSection 3.2.3) can be used to do   this.Surtees & West               Informational                      [Page 7]

RFC 4464                  SigComp Users' Guide                  May 2006   It is also possible to assign integer values to text names: when a   text name is encountered in an expression, it is replaced by the   integer value assigned to it.Section 3.2.3 explains how to assign   integer values to text names.3.2.2.  Instructions   A UDVM instruction is specified by the instruction opcode followed by   zero or more operands.  The instruction operands are enclosed in   parentheses and separated by commas, for example:   ADD ($3, 4)   When generating the bytecode, the parser should replace the   instruction opcode with the corresponding 1-byte value as per Figure   11 of SigComp [2].   Each operand consists of an expression that evaluates to an integer,   optionally preceded by the symbol "$".  This symbol indicates that   the supplied integer value must be interpreted as the memory address   at which the operand value can be found, rather than the actual   operand value itself.   When converting each instruction operand to bytecode, the parser   first determines whether the instruction expects the operand to be a   literal, a reference, a multitype, or an address.  If the operand is   a literal, then, as per Figure 8 of SigComp, the parser inserts   bytecode (usually the shortest) capable of encoding the supplied   operand value.   Since literal operands are used to indicate the total number of   operands for an instruction, it is possible to leave a literal   operand blank and allow its value to be inferred automatically by the   assembler.  For example:   MULTILOAD (64, , 1, 2, 3, 4)   The missing operand should be given the value 4 because it is   followed by a total of 4 operands.   If the operand is a reference, then, as per Figure 9 of SigComp, the   parser inserts bytecode (usually the shortest) capable of encoding   the supplied memory address.  Note that reference operands will   always be preceded by the symbol "$" in assembly because they always   encode memory addresses rather than actual operand values.Surtees & West               Informational                      [Page 8]

RFC 4464                  SigComp Users' Guide                  May 2006   If the operand is a multitype, then the parser first checks whether   the symbol "$" is present.  If so, then, as per Figure 10 of SigComp,   it inserts bytecode (usually the shortest) capable of encoding the   supplied integer as a memory address.  If not, then, as per Figure 10   of SigComp, it inserts bytecode (usually the shortest) that encodes   the supplied integer as an operand value.   If the operand is an address, then the parser checks whether the   symbol "$" is present.  If so, then the supplied integer is encoded   as a memory address, just as for the multitype instruction above.  If   not, then the byte position of the opcode is subtracted from the   supplied integer modulo 16, and the result is encoded as an operand   value as per Figure 10 of SigComp.   The length of the resulting bytecode is dependent on the parser in   use.  There can be several correct and usable representations of the   same instruction.3.2.3.  Directives   The assembly language provides a number of directives for evaluating   expressions, moving instructions to a particular memory address, etc.   The directives "pad", "align", and "at" can be used to add padding to   the bytecode.   The directive "pad (n)" appends n consecutive padding bytes to the   bytecode.  The actual value of the padding bytes is unimportant, so   when the bytecode is uploaded to the UDVM, the padding bytes can be   set to the initial values contained in the UDVM memory (this helps to   reduce the size of a SigComp message).   The directive "align (n)" appends the minimum number of padding bytes   to the bytecode such that the total number of bytes of bytecode   generated so far is a multiple of n bytes.  If the bytecode is   already aligned to a multiple of n bytes, then no padding bytes are   added.   The directive "at (n)" appends enough padding bytes to the bytecode   such that the total number of bytes of bytecode generated so far is   exactly n bytes.  If more than n bytes have already been generated   before the "at" directive is encountered then the assembly code   contains an error.   The directives "byte" and "word" can be used to add specific data   strings to the bytecode.Surtees & West               Informational                      [Page 9]

RFC 4464                  SigComp Users' Guide                  May 2006   The directive "byte (n[0],..., n[k-1])" appends k consecutive bytes   to the bytecode.  The byte string is supplied as expressions that   evaluate to give integers n[0],..., n[k-1] from 0 to 255.   The directive "word (n[0],..., n[k-1])" appends k consecutive 2-byte   words to the bytecode.  The word string is supplied as expressions   that evaluate to give integers n[0],..., n[k-1] from 0 to 65535.   The directive "set (name, n)" assigns an integer value n to a   specified text name.  The integer value can be supplied in the form   of an expression.   The directive "readonly (n)" where n is 0 or 1 can be used to   indicate that an area of memory could be changed (0) or will not be   changed (1) during the execution of the UDVM.  This directive could   be used, for example, in conjunction with "!" to ensure that the   address of the zero used will still contain zero when the bytecode is   executed.  If no readonly directive is used, then any address   containing zero can be used by "!" (i.e., by default, there is   assumed to be a readonly (1) directive at Address 0) and it is up to   the author of the assembly code to ensure that the address in   question will still contain zero when the bytecode is executed.  If   the readonly directive is used, then bytes between a readonly (0) and   readonly (1) pair are NOT to be used by "!".  When a readonly   directive has been used, the bytes obey that directive from that   address to either another readonly directive or the end of UDVM   memory, whichever comes first.3.2.4.  Labels   A label is a special directive used to assign memory addresses to   text names.   Labels are specified by a single colon followed by the text name to   be defined.  The (absolute) position of the byte immediately   following the label is evaluated and assigned to the text name.  For   example:   :start   LOAD (temp, 1)   Since the label "start" occurs at the beginning of the bytecode, it   is assigned the integer value 0.   Note that writing the label ":name" has exactly the same behavior as   writing the directive "set (name, .)".Surtees & West               Informational                     [Page 10]

RFC 4464                  SigComp Users' Guide                  May 20063.3.  Uploading the Bytecode to the UDVM   Once the parser has converted a string of assembly into the   corresponding bytecode, it must be copied to the UDVM memory   beginning at Address 0 and then executed, beginning from the first   UDVM instruction in the bytecode.   SigComp provides the following message format for uploading bytecode   to the UDVM:     0   1   2   3   4   5   6   7   +---+---+---+---+---+---+---+---+   | 1   1   1   1   1 | T |   0   |   +---+---+---+---+---+---+---+---+   |                               |   :    returned feedback item     :  if T = 1   |                               |   +---+---+---+---+---+---+---+---+   |           code_len            |   +---+---+---+---+---+---+---+---+   |   code_len    |  destination  |   +---+---+---+---+---+---+---+---+   |                               |   :    uploaded UDVM bytecode     :   |                               |   +---+---+---+---+---+---+---+---+   |                               |   :   remaining SigComp message   :   |                               |   +---+---+---+---+---+---+---+---+   The destination field should be set to the memory address of the   first UDVM instruction.  Note that if this address cannot be   represented by the destination field, then the bytecode cannot be   uploaded to the UDVM using the standard SigComp header.  In   particular, the memory address of the first UDVM instruction must   always be a multiple of 64 bytes or the standard SigComp header   cannot be used.  Of course, there may be other ways to upload the   bytecode to the UDVM, such as retrieving the bytecode directly via   the INPUT-BYTES instruction.   Additionally, all memory addresses between Address 0 and Address 31   inclusive are initialized to endpoint-specific values by the UDVM, so   they must be specified as padding in the bytecode, or the standard   SigComp header cannot be used.  Memory addresses from Address 32 to   Address (destination - 1) inclusive are initialized to 0, so they   must be specified either as padding or as 0s if the bytecode is to be   successfully uploaded using the standard SigComp header.Surtees & West               Informational                     [Page 11]

RFC 4464                  SigComp Users' Guide                  May 2006   The code_len field should be set to the smallest value such that all   memory addresses beginning at Address (destination + code_len) are   either as initialised by the UDVM (to 0) or as set by the bytecode at   runtime.   The "uploaded UDVM bytecode" should be set to contain the segment of   bytecode that lies between Address (destination) and Address   (destination + code_len - 1) inclusive.4.  Compression Algorithms   This section describes a number of compression algorithms that can be   used by a SigComp compressor.  In each case, the document provides   UDVM bytecode for the corresponding decompression algorithm, which   can be uploaded to the receiving endpoint as part of a SigComp   message.  Each algorithm (as written in this section) assumes that   there is a 16K decompression memory size, there are 16 cycles per   bit, and there is an 8K state memory size.  Decompression will   succeed with a smaller value for state memory size; however, the full   state will not be created.Section 4.1.1 covers a simple algorithm in some detail, including the   steps required to compress and decompress a SigComp message.  The   remaining sections cover well-known compression algorithms that can   be adapted for use in SigComp with minimal modification.4.1.  Well-known Compression Algorithms4.1.1.  LZ77   This section describes how to implement a very simple compression   algorithm based on LZ77 [5].   A compressed message generated by the simplified LZ77 scheme consists   of a sequence of 4-byte characters, where each character contains a   2-byte position value followed by a 2-byte length value.  Each pair   of integers identifies a byte string in the UDVM memory; when   concatenated, these byte strings form the decompressed message.   When implementing a bytecode decompressor for the simplified LZ77   scheme, the UDVM memory is partitioned into five distinct areas, as   shown below:   0             64          128        256          512   | scratch-pad | variables | bytecode | dictionary | circular buffer |   +-------------+-----------+----------+------------+-----------------+    <-----------> <---------> <--------> <----------> <--------------->       64 bytes     64 bytes   128 bytes   256 bytes      512+ bytesSurtees & West               Informational                     [Page 12]

RFC 4464                  SigComp Users' Guide                  May 2006   The first 128 bytes are used to hold the 2-byte variables needed by   the LZ77 decompressor.  Within this memory, the first 64 bytes are   used as a scratch-pad, holding the 2-byte variables that can be   discarded between SigComp messages.  In contrast, the next 64 bytes   (and in fact all of the UDVM memory starting from Address 64) should   be saved after decompressing a SigComp message to improve the   compression ratio of subsequent messages.   The bytecode for the LZ77 decompressor is stored beginning at Address   128.  A total of 128 bytes are reserved for the bytecode although the   LZ77 decompressor requires less; this allows room for adding   additional features to the decompressor at a later stage.   The next 256 bytes are initialized by the bytecode to contain the   integers 0 to 255 inclusive.  The purpose of this memory area is to   provide a dictionary of all possible uncompressed characters; this is   important to ensure that the compressor can always generate a   sequence of position/length pairs that encode a given message.  For   example, a byte with value 0x41 (corresponding to the ASCII character   "A") can be found at Address 0x0141 of the UDVM memory, so the   compressed character 0x0141 0001 will decompress to give this ASCII   character.  Note that encoding each byte in the application message   as a separate 4-byte compressed character is not recommended,   however, as the resulting "compressed" message is four times as large   as the original uncompressed message.   The compression ratio of LZ77 is improved by the remaining UDVM   memory, which is used to store a history buffer containing the   previously decompressed messages.  Compressed characters can point to   strings that have previously been decompressed and stored in the   buffer, so the overall compression ratio of the LZ77 algorithm   improves as the decompressor "learns" more text strings and is able   to encode longer strings using a single compressed character.  The   buffer is circular, so older messages are overwritten by new data   when the buffer becomes full.   The steps required to implement an LZ77 compressor and decompressor   are similar, although compression is more processor-intensive as it   requires a searching operation to be performed.  Assembly for the   simplified LZ77 decompressor is given below:   ; Variables that do not need to be stored after decompressing each   ; SigComp message are stored here:   at (32)   :position_value                 pad (2)   :length_value                   pad (2)Surtees & West               Informational                     [Page 13]

RFC 4464                  SigComp Users' Guide                  May 2006   at (42)   set (requested_feedback_location, 0)   ; The UDVM registers must be stored beginning at Address 64:   at (64)   ; Variables that should be stored after decompressing a message are   ; stored here.  These variables will form part of the SigComp state   ; item created by the bytecode:   :byte_copy_left                 pad (2)   :byte_copy_right                pad (2)   :decompressed_pointer           pad (2)   set (returned_parameters_location, 0)   align (64)   :initialize_memory   set (udvm_memory_size, 8192)   set (state_length, (udvm_memory_size - 64))   ; The UDVM registers byte_copy_left and byte_copy_right are set to   ; indicate the bounds of the circular buffer in the UDVM memory.  A   ; variable decompressed_pointer is also created and set pointing to   ; the start of the circular buffer:   MULTILOAD (64, 3, circular_buffer, udvm_memory_size, circular_buffer)   ; The "dictionary" area of the UDVM memory is initialized to contain   ; the values 0 to 255 inclusive:   MEMSET (static_dictionary, 256, 0, 1)   :decompress_sigcomp_message   :next_character   ; The next character in the compressed message is read by the UDVM   ; and the position and length integers are stored in the variables   ; position_value and length_value, respectively.  If no more   ; compressed data is available, the decompressor jumps to the   ; "end_of_message" subroutine:   INPUT-BYTES (4, position_value, end_of_message)Surtees & West               Informational                     [Page 14]

RFC 4464                  SigComp Users' Guide                  May 2006   ; The position_value and length_value point to a byte string in the   ; UDVM memory, which is copied into the circular buffer at the   ; position specified by decompressed_pointer.  This allows the string   ; to be referenced by later characters in the compressed message:   COPY-LITERAL ($position_value, $length_value, $decompressed_pointer)   ; The byte string is also outputted onto the end of the decompressed   ; message:   OUTPUT ($position_value, $length_value)   ; The decompressor jumps back to consider the next character in the   ; compressed message:   JUMP (next_character)   :end_of_message   ; The decompressor saves the UDVM memory and halts:   END-MESSAGE (requested_feedback_location,   returned_parameters_location, state_length, 64,   decompress_sigcomp_message, 6, 0)   at (256)   ; Memory for the dictionary and the circular buffer are reserved by   ; the following statements:   :static_dictionary              pad (256)   :circular_buffer   The task of an LZ77 compressor is simply to discover a sequence of   4-byte compressed characters that the above bytecode will decompress   to give the desired application message.  As an example, a message   compressed using the simplified LZ77 algorithm is given below:   0x0154 0001 0168 0001 0165 0001 0120 0001 0152 0001 0165 0001 0173   0x0002 0161 0001 0175 0001 0172 0001 0161 0001 016e 0001 0174 0001   0x0120 0001 0161 0001 020d 0002 0174 0001 0201 0003 0145 0001 016e   0x0001 0164 0001 0120 0001 016f 0001 0166 0001 0211 0005 0155 0001   0x016e 0001 0169 0001 0176 0001 0165 0001 0172 0002 0165 0001 010a   0x0001   The uncompressed message is "The Restaurant at the End of the   Universe\n".Surtees & West               Informational                     [Page 15]

RFC 4464                  SigComp Users' Guide                  May 2006   The bytecode for the LZ77 decompressor can be uploaded as part of the   compressed message, as specified inSection 3.3.  However, in order   to improve the overall compression ratio, it is important to avoid   uploading bytecode in every compressed message.  For this reason,   SigComp allows the UDVM to save an area of its memory as a state item   between compressed messages.  Once a state item has been created, it   can be retrieved by sending the corresponding state identifier using   the following SigComp message format:     0   1   2   3   4   5   6   7   +---+---+---+---+---+---+---+---+   | 1   1   1   1   1 | T |   1   |   +---+---+---+---+---+---+---+---+   |                               |   :    returned feedback item     :  if T = 1   |                               |   +---+---+---+---+---+---+---+---+   |                               |   :   partial state identifier    :   |                               |   +---+---+---+---+---+---+---+---+   |                               |   :   remaining SigComp message   :   |                               |   +---+---+---+---+---+---+---+---+   The partial_state_identifier field must contain the first 6 bytes of   the state identifier for the state item to be accessed (see [2] for   details of how state identifiers are derived).   Note that the partial_state_identifier field could be 9 or 12 bytes   and that in these cases, bits 6 and 7 of the first byte of the   message would be 10 or 11, respectively.4.1.2.  LZSS   This section provides UDVM bytecode for the simple but effective LZSS   compression algorithm [6].   The principal improvement offered by LZSS over LZ77 is that each   compressed character begins with a 1-bit indicator flag to specify   whether the character is a literal or an offset/length pair.  A   literal value is simply a single uncompressed byte that is appended   directly to the decompressed message.   An offset/length pair contains a 12-bit offset value from 1 to 4096   inclusive, followed by a 4-bit length value from 3 to 18 inclusive.   Taken together, these values specify one of the previously receivedSurtees & West               Informational                     [Page 16]

RFC 4464                  SigComp Users' Guide                  May 2006   text strings in the circular buffer, which is then appended to the   end of the decompressed message.   Assembly for an LZSS decompressor is given below:   at (32)   readonly (0)   :index                          pad (2)   :length_value                   pad (2)   :old_pointer                    pad (2)   at (42)   set (requested_feedback_location, 0)   at (64)   :byte_copy_left                 pad (2)   :byte_copy_right                pad (2)   :input_bit_order                pad (2)   :decompressed_pointer           pad (2)   set (returned_parameters_location, 0)   align (64)   readonly (1)   :initialize_memory   set (udvm_memory_size, 8192)   set (state_length, (udvm_memory_size - 64))   MULTILOAD (64, 4, circular_buffer, udvm_memory_size, 0,   circular_buffer)   :decompress_sigcomp_message   :next_character   INPUT-HUFFMAN (index, end_of_message, 2, 9, 0, 255, 16384, 4, 4096,   8191, 1)   COMPARE ($index, 8192, length, end_of_message, literal)   :literal   set (index_lsb, (index + 1))Surtees & West               Informational                     [Page 17]

RFC 4464                  SigComp Users' Guide                  May 2006   OUTPUT (index_lsb, 1)   COPY-LITERAL (index_lsb, 1, $decompressed_pointer)   JUMP (next_character)   :length   INPUT-BITS (4, length_value, !)   ADD ($length_value, 3)   LOAD (old_pointer, $decompressed_pointer)   COPY-OFFSET ($index, $length_value, $decompressed_pointer)   OUTPUT ($old_pointer, $length_value)   JUMP (next_character)   :end_of_message   END-MESSAGE (requested_feedback_location,   returned_parameters_location, state_length, 64,   decompress_sigcomp_message, 6, 0)   readonly (0)   :circular_buffer   An example of a message compressed using the LZSS algorithm is given   below:   0x279a 0406 e378 b200 6074 1018 4ce6 1349 b842   The uncompressed message is "Oh no, not again!".4.1.3.  LZW   This section provides UDVM bytecode for the well-known LZW   compression algorithm LZW [7].  This algorithm is used in a number of   standards including the GIF image format.   LZW compression operates in a similar manner to LZ77 in that it   maintains a circular buffer of previously received decompressed data,   and each compressed character references exactly one byte string from   the circular buffer.  However, LZW also maintains a "codebook"   containing 1024 position/length pairs that point to byte strings that   LZW believes are most likely to occur in the uncompressed data.   The byte strings stored in the LZW codebook can be referenced by   sending a single 10-bit value from 0 to 1023 inclusive.  The UDVM   extracts the corresponding text string from the codebook and appends   it to the end of the decompressed message.  It then creates a new   codebook entry containing the current text string and the next   character to occur in the decompressed message.Surtees & West               Informational                     [Page 18]

RFC 4464                  SigComp Users' Guide                  May 2006   Assembly for an LZW decompressor is given below:   at (32)   :length_value                   pad (2)   :position_value                 pad (2)   :index                          pad (2)   at (42)   set (requested_feedback_location, 0)   at (64)   :byte_copy_left                 pad (2)   :byte_copy_right                pad (2)   :input_bit_order                pad (2)   :codebook_next                  pad (2)   :current_length                 pad (2)   :decompressed_pointer           pad (2)   set (returned_parameters_location, 0)   align (64)   :initialize_memory   set (udvm_memory_size, 8192)   set (state_length, (udvm_memory_size - 64))   MULTILOAD (64, 6, circular_buffer, udvm_memory_size, 0, codebook, 1,   static_dictionary)   :initialize_codebook   ; The following instructions are used to initialize the first 256   ; entries in the LZW codebook with single ASCII characters:   set (index_lsb, (index + 1))   set (current_length_lsb, (current_length + 1))   COPY-LITERAL (current_length_lsb, 3, $codebook_next)   COPY-LITERAL (index_lsb, 1, $decompressed_pointer)   ADD ($index, 1)   COMPARE ($index, 256, initialize_codebook, next_character, 0)   :decompress_sigcomp_messageSurtees & West               Informational                     [Page 19]

RFC 4464                  SigComp Users' Guide                  May 2006   :next_character   ; The following INPUT-BITS instruction extracts 10 bits from the   ; compressed message:   INPUT-BITS (10, index, end_of_message)   ; The following instructions interpret the received bits as an index   ; into the LZW codebook and extract the corresponding   ; position/length pair:   set (length_value_lsb, (length_value + 1))   MULTIPLY ($index, 3)   ADD ($index, codebook)   COPY ($index, 3, length_value_lsb)   ; The following instructions append the selected text string to the   ; circular buffer and create a new codebook entry pointing to this   ; text string:   LOAD (current_length, 1)   ADD ($current_length, $length_value)   COPY-LITERAL (current_length_lsb, 3, $codebook_next)   COPY-LITERAL ($position_value, $length_value, $decompressed_pointer)   ; The following instruction outputs the text string specified by the   ; position/length pair:   OUTPUT ($position_value, $length_value)   JUMP (next_character)   :end_of_message   END-MESSAGE (requested_feedback_location,   returned_parameters_location, state_length, 64,   decompress_sigcomp_message, 6, 0)   :static_dictionary              pad (256)   :circular_buffer   at (4492)   :codebookSurtees & West               Informational                     [Page 20]

RFC 4464                  SigComp Users' Guide                  May 2006   An example of a message compressed using the LZW algorithm is given   below:   0x14c6 f080 6c1b c6e1 9c20 1846 e190 201d 0684 206b 1cc2 0198 6f1c   0x9071 b06c 42c6 8195 111a 4731 a021 02bf f0   The uncompressed message is "So long and thanks for all the fish!\n".4.1.4.  DEFLATE   This section provides UDVM bytecode for the DEFLATE compression   algorithm.  DEFLATE is the algorithm used in the well-known "gzip"   file format.   The following bytecode will decompress the DEFLATE compressed data   format [8] with the following modifications:   1.  The DEFLATE compressed data format separates blocks of compressed       data by transmitting 7 consecutive zero bits.  Each SigComp       message is assumed to contain a separate block of compressed       data, so the end-of-block bits are implicit and do not need to be       transmitted at the end of a SigComp message.   2.  This bytecode supports only DEFLATE block type 01 (data       compressed with fixed Huffman codes).   Assembly for the DEFLATE decompressor is given below:   at (32)   readonly (0)   :index                          pad (2)   :extra_length_bits              pad (2)   :length_value                   pad (2)   :extra_distance_bits            pad (2)   :distance_value                 pad (2)   at (42)   set (requested_feedback_location, 0)   at (64)   :byte_copy_left                 pad (2)   :byte_copy_right                pad (2)   :input_bit_order                pad (2)   :decompressed_pointer           pad (2)Surtees & West               Informational                     [Page 21]

RFC 4464                  SigComp Users' Guide                  May 2006   :length_table                   pad (116)   :distance_table                 pad (120)   set (returned_parameters_location, 0)   align (64)   readonly (1)   :initialize_memory   set (udvm_memory_size, 8192)   set (state_length, (udvm_memory_size - 64))   set (length_table_start, (((length_table - 4) + 65536) / 4))   set (length_table_mid, (length_table_start + 24))   set (distance_table_start, (distance_table / 4))   MULTILOAD (64, 122, circular_buffer, udvm_memory_size, 5,   circular_buffer,   0,       3,       0,       4,       0,       5,   0,       6,       0,       7,       0,       8,   0,       9,       0,       10,      1,       11,   1,       13,      1,       15,      1,       17,   2,       19,      2,       23,      2,       27,   2,       31,      3,       35,      3,       43,   3,       51,      3,       59,      4,       67,   4,       83,      4,       99,      4,       115,   5,       131,     5,       163,     5,       195,   5,       227,     0,       258,   0,       1,       0,       2,       0,       3,   0,       4,       1,       5,       1,       7,   2,       9,       2,       13,      3,       17,   3,       25,      4,       33,      4,       49,   5,       65,      5,       97,      6,       129,   6,       193,     7,       257,     7,       385,   8,       513,     8,       769,     9,       1025,   9,       1537,    10,      2049,    10,      3073,   11,      4097,    11,      6145,    12,      8193,   12,      12289,   13,      16385,   13,      24577)   :decompress_sigcomp_message   INPUT-BITS (3, extra_length_bits, !)   :next_characterSurtees & West               Informational                     [Page 22]

RFC 4464                  SigComp Users' Guide                  May 2006   INPUT-HUFFMAN (index, end_of_message, 4,       7, 0, 23, length_table_start,       1, 48, 191, 0,       0, 192, 199, length_table_mid,       1, 400, 511, 144)   COMPARE ($index, length_table_start, literal, end_of_message,   length_distance)   :literal   set (index_lsb, (index + 1))   OUTPUT (index_lsb, 1)   COPY-LITERAL (index_lsb, 1, $decompressed_pointer)   JUMP (next_character)   :length_distance   ; this is the length part   MULTIPLY ($index, 4)   COPY ($index, 4, extra_length_bits)   INPUT-BITS ($extra_length_bits, extra_length_bits, !)   ADD ($length_value, $extra_length_bits)   ; this is the distance part   INPUT-HUFFMAN (index, !, 1, 5, 0, 31, distance_table_start)   MULTIPLY ($index, 4)   COPY ($index, 4, extra_distance_bits)   INPUT-BITS ($extra_distance_bits, extra_distance_bits, !)   ADD ($distance_value, $extra_distance_bits)   LOAD (index, $decompressed_pointer)   COPY-OFFSET ($distance_value, $length_value, $decompressed_pointer)   OUTPUT ($index, $length_value)   JUMP (next_character)   :end_of_message   END-MESSAGE (requested_feedback_location,   returned_parameters_location, state_length, 64,   decompress_sigcomp_message, 6, 0)   readonly (0)   :circular_bufferSurtees & West               Informational                     [Page 23]

RFC 4464                  SigComp Users' Guide                  May 2006   An example of a message compressed using the DEFLATE algorithm is   given below:   0xf3c9 4c4b d551 28c9 4855 08cd cb2c 4b2d 2a4e 5548 cc4b 5170 0532   0x2b4b 3232 f3d2 b900   The uncompressed message is "Life, the Universe and Everything\n".4.1.5.  LZJH   This section provides UDVM bytecode for the LZJH compression   algorithm.  LZJH is the algorithm adopted by the International   Telecommunication Union (ITU-T) Recommendation V.44 [9].   Assembly for the LZJH decompressor is given below:   at (32)   readonly (0)   ; The following 2-byte variables are stored in the scratch-pad memory   ; area because they do not need to be saved after decompressing a   ; SigComp message:   :length_value                   pad (2)   :position_value                 pad (2)   :index                          pad (2)   :extra_extension_bits           pad (2)   :codebook_old                   pad (2)   at (42)   set (requested_feedback_location, 0)   at (64)   ; UDVM_registers   :byte_copy_left                 pad (2)   :byte_copy_right                pad (2)   :input_bit_order                pad (2)Surtees & West               Informational                     [Page 24]

RFC 4464                  SigComp Users' Guide                  May 2006   ; The following 2-byte variables are saved as state after   ; decompressing a SigComp message:   :current_length                 pad (2)   :decompressed_pointer           pad (2)   :ordinal_length                 pad (2)   :codeword_length                pad (2)   :codebook_next                  pad (2)   set (returned_parameters_location, 0)   align (64)   readonly (1)   :initialize_memory   ; The following constants can be adjusted to configure the LZJH   ; decompressor.  The current settings are as recommended in the V.44   ; specification (given that a total of 8K UDVM memory is available):   set (udvm_memory_size, 8192)   ; sets the total memory for LZJH   set (max_extension_length, 8)  ; sets the maximum string extension   set (min_ordinal_length, 7)    ; sets the minimum ordinal length   set (min_codeword_length, 6)   ; sets the minimum codeword length   set (codebook_start, 4492)   set (first_codeword, (codebook_start - 12))   set (state_length, (udvm_memory_size - 64))   MULTILOAD (64, 8, circular_buffer, udvm_memory_size, 7, 0,   circular_buffer, min_ordinal_length, min_codeword_length,   codebook_start)   :decompress_sigcomp_message   :standard_prefix   ; The following code decompresses the standard 1-bit LZJH prefix   ; that specifies whether the next character is an ordinal or a   ; codeword/control value:   INPUT-BITS (1, index, end_of_message)   COMPARE ($index, 1, ordinal, codeword_control, codeword_control)   :prefix_after_codewordSurtees & West               Informational                     [Page 25]

RFC 4464                  SigComp Users' Guide                  May 2006   ; The following code decompresses the special LZJH prefix that only   ; occurs after a codeword.  It specifies whether the next character   ; is an ordinal, a codeword/control value, or a string extension:   INPUT-HUFFMAN (index, end_of_message, 2, 1, 1, 1, 2, 1, 0, 1, 0)   COMPARE ($index, 1, ordinal, string_extension, codeword_control)   :ordinal   ; The following code decompresses an ordinal character and creates   ; a new codebook entry consisting of the ordinal character and the   ; next character to be decompressed:   set (index_lsb, (index + 1))   set (current_length_lsb, (current_length + 1))   INPUT-BITS ($ordinal_length, index, !)   OUTPUT (index_lsb, 1)   LOAD (current_length, 2)   COPY-LITERAL (current_length_lsb, 3, $codebook_next)   COPY-LITERAL (index_lsb, 1, $decompressed_pointer)   JUMP (standard_prefix)   :codeword_control   ; The following code decompresses a codeword/control value:   INPUT-BITS ($codeword_length, index, !)   COMPARE ($index, 3, control_code, initialize_memory, codeword)   :codeword   ; The following code interprets a codeword as an index into the LZJH   ; codebook.  It extracts the position/length pair from the specified   ; codebook entry; the position/length pair points to a byte string   ; in the circular buffer, which is then copied to the end of the   ; decompressed message.  The code also creates a new codebook entry   ; consisting of the byte string plus the next character to be   ; decompressed:   set (length_value_lsb, (length_value + 1))   MULTIPLY ($index, 3)   ADD ($index, first_codeword)   COPY ($index, 3, length_value_lsb)   LOAD (current_length, 1)   ADD ($current_length, $length_value)   LOAD (codebook_old, $codebook_next)Surtees & West               Informational                     [Page 26]

RFC 4464                  SigComp Users' Guide                  May 2006   COPY-LITERAL (current_length_lsb, 3, $codebook_next)   COPY-LITERAL ($position_value, $length_value, $decompressed_pointer)   OUTPUT ($position_value, $length_value)   JUMP (prefix_after_codeword)   :string_extension   ; The following code decompresses a Huffman-encoded string extension:   INPUT-HUFFMAN (index, !, 4, 1, 1, 1, 1, 2, 1, 3, 2, 1, 1, 1, 13, 3,   0, 7, 5)   COMPARE ($index, 13, continue, extra_bits, extra_bits)   :extra_bits   INPUT-BITS (max_extension_length, extra_extension_bits, !)   ADD ($index, $extra_extension_bits)   :continue   ; The following code extends the most recently created codebook entry   ; by the number of bits specified in the string extension:   COPY-LITERAL ($position_value, $length_value, $position_value)   COPY-LITERAL ($position_value, $index, $decompressed_pointer)   OUTPUT ($position_value, $index)   ADD ($index, $length_value)   COPY (index_lsb, 1, $codebook_old)   JUMP (standard_prefix)   :control_code   ; The code can handle all of the control characters in V.44 except   ; for ETM (Enter Transparent Mode), which is not required for   ; message-based protocols such as SigComp.   COMPARE ($index, 1, !, flush, stepup)   :flush   ; The FLUSH control character jumps to the beginning of the next   ; complete byte in the compressed message:   INPUT-BYTES (0, 0, 0)   JUMP (standard_prefix)   :stepupSurtees & West               Informational                     [Page 27]

RFC 4464                  SigComp Users' Guide                  May 2006   ; The STEPUP control character increases the number of bits used to   ; encode an ordinal value or a codeword:   INPUT-BITS (1, index, !)   COMPARE ($index, 1, stepup_ordinal, stepup_codeword, 0)   :stepup_ordinal   ADD ($ordinal_length, 1)   JUMP (ordinal)   :stepup_codeword   ADD ($codeword_length, 1)   JUMP (codeword_control)   :end_of_message   END-MESSAGE (requested_feedback_location,   returned_parameters_location, state_length, 64,   decompress_sigcomp_message, 6, 0)   readonly (0)   :circular_buffer   An example of a message compressed using the LZJH algorithm is given   below:   0x5c09 e6e0 cadc c8d2 dcce 40c2 40f2 cac2 e440 c825 c840 ccde 29e8   0xc2f0 40e0 eae4 e0de e6ca e65c 1403   The uncompressed message is "...spending a year dead for tax   purposes.\n".4.2.  Adapted Algorithms4.2.1.  Modified DEFLATE   Alternative algorithms can also be used with SigComp.  This section   shows a modified version of the DEFLATE [8] algorithm.  The two-stage   encoding of DEFLATE is replaced by a single step with a discrete   Huffman code for each symbol.  The literal/length symbol   probabilities are dependent upon whether the previous symbol was a   literal or a match.  Bit handling is also simpler, in that all bits   are input using the INPUT-HUFFMAN instruction and the value of the H   bit does not change so all bits are input, read, and interpreted in   the same order.Surtees & West               Informational                     [Page 28]

RFC 4464                  SigComp Users' Guide                  May 2006   Assembly for the algorithm is given below.  String matching rules are   the same as for the other LZ-based algorithms, with the alternative   encoding of the literals and length/distance pairs.   at (32)   readonly (0)   :index                          pad (2)   :distance_value                 pad (2)   :old_pointer                    pad (2)   at (42)   set (requested_feedback_location, 0)   at (64)   :byte_copy_left                 pad (2)   :byte_copy_right                pad (2)   :input_bit_order                pad (2)   :decompressed_pointer           pad (2)   set (returned_parameters_location, 0)   at (128)   readonly (1)   :initialize_memory   set (udvm_memory_size, 8192)   set (state_length, (udvm_memory_size - 64))   MULTILOAD (64, 4, circular_buffer, udvm_memory_size, 0,   circular_buffer)   :decompress_sigcomp_message   :character_after_literal   INPUT-HUFFMAN (index, end_of_message, 16,       5, 0, 11, 46,       0, 12, 12, 256,       1, 26, 32, 257,       1, 66, 68, 32,       0, 69, 94, 97,       0, 95, 102, 264,       0, 103, 103, 511,       2, 416, 426, 35,Surtees & West               Informational                     [Page 29]

RFC 4464                  SigComp Users' Guide                  May 2006       0, 427, 465, 58,       0, 466, 481, 272,       1, 964, 995, 288,       3, 7968, 7988, 123,       0, 7989, 8115, 384,       1, 16232, 16263, 0,       0, 16264, 16327, 320,       1, 32656, 32767, 144)   COMPARE ($index, 256, literal, distance, distance)   :character_after_match   INPUT-HUFFMAN (index, end_of_message, 16,       4, 0, 0, 511,       1, 2, 9, 256,       1, 20, 22, 32,       0, 23, 30, 264,       1, 62, 73, 46,       0, 74, 89, 272,       2, 360, 385, 97,       0, 386, 417, 288,       1, 836, 874, 58,       0, 875, 938, 320,       1, 1878, 1888, 35,       0, 1889, 2015, 384,       1, 4032, 4052, 123,       1, 8106, 8137, 0,       1, 16276, 16379, 144,       1, 32760, 32767, 248)   COMPARE ($index, 256, literal, distance, distance)   :literal   set (index_lsb, (index + 1))   OUTPUT (index_lsb, 1)   COPY-LITERAL (index_lsb, 1, $decompressed_pointer)   JUMP (character_after_literal)   :distance   SUBTRACT ($index, 253)   INPUT-HUFFMAN (distance_value, !, 9,       9, 0, 7, 9,       0, 8, 63, 129,       1, 128, 135, 1,Surtees & West               Informational                     [Page 30]

RFC 4464                  SigComp Users' Guide                  May 2006       0, 136, 247, 17,       0, 248, 319, 185,       1, 640, 1407, 257,       2, 5632, 6655, 1025,       1, 13312, 15359, 2049,       2, 61440, 65535, 4097)   LOAD (old_pointer, $decompressed_pointer)   COPY-OFFSET ($distance_value, $index, $decompressed_pointer)   OUTPUT ($old_pointer, $index)   JUMP (character_after_match)   :end_of_message   END-MESSAGE (requested_feedback_location,   returned_parameters_location, state_length, 64,   decompress_sigcomp_message, 6, 0)   readonly (0)   :circular_buffer   An example of a message compressed using the modified DEFLATE   algorithm is given below:   0xd956 b132 cd68 5424 c5a9 6215 8a70 a64d af0a 5499 3621 509b 3e4c   0x28b4 a145 b362 653a d0a6 498b 5a6d 2970 ac4c 930a a4ca 74a4 c268   0x0c   The uncompressed message is "Arthur leapt to his feet like an author   hearing the phone ring".5.  Additional SigComp Mechanisms   This section covers the additional mechanisms that can be employed by   SigComp to improve the overall compression ratio, including the use   of acknowledgements, dictionaries, and sharing state between two   directions of a compressed message flow.   An example of assembly code is provided for these mechanisms.   Depending on the mechanism and basic algorithm in use, the assembly   code for either the mechanism or the basic algorithm may require   modification (e.g., if the algorithm uses 'no more input' to jump to   end_of_message, following end_of_message with an input instruction   for CRC will not work).  In any case, these are examples and there   may be alternative ways to make use of the mechanisms.Surtees & West               Informational                     [Page 31]

RFC 4464                  SigComp Users' Guide                  May 2006   When each of the compression algorithms described inSection 4 has   successfully decompressed the current SigComp message, the contents   of the UDVM memory are saved as a SigComp state item.  Subsequent   messages can access this state item by uploading the correct state   identifier to the receiving endpoint, which avoids the need to upload   the bytecode for the compression algorithm on a per-message basis.   However, before a state item can be accessed, the compressor must   first ensure that it is available at the receiving endpoint.   For each SigComp compartment, the receiving endpoint maintains a list   of currently available states (where the total amount of state saved   does not exceed the state_memory_size for the compartment).  The   SigComp compressor should maintain a similar list containing the   states that it has instructed the receiving endpoint to save.   As well as tracking the list of state items that it has saved at the   remote endpoint, the compressor also maintains a flag for each state   item indicating whether or not the state can safely be accessed.   State items should not be accessed until they have been acknowledged   (e.g., by using the SigComp feedback mechanism as perSection 5.1).   State items are deleted from the list when adding a new piece of   state when the total state_memory_size for the compartment is full.   The state to be deleted is determined according to age and retention   priority as discussed in SigComp [2].  The SigComp compressor should   not attempt to access any state items that have been deleted in this   manner, as they may no longer be available at the receiving endpoint.5.1.  Acknowledging a State Item   SigComp [2] defines a feedback mechanism to allow the compressor to   request feedback from the decompressor, to give the compressor   indication that a message has been received and correctly   decompressed and that state storage has been attempted.  (Note: This   mechanism cannot convey the success or failure of individual state   creation requests.)  In order to invoke the feedback mechanism, the   following fields must be reserved in the UDVM memory:     0   1   2   3   4   5   6   7   +---+---+---+---+---+---+---+---+   |     reserved      | Q | S | I |  requested_feedback_location   +---+---+---+---+---+---+---+---+   | 1 | requested_feedback_length |  if Q = 1   +---+---+---+---+---+---+---+---+   |                               |   :   requested_feedback_field    :  if Q = 1   |                               |   +---+---+---+---+---+---+---+---+Surtees & West               Informational                     [Page 32]

RFC 4464                  SigComp Users' Guide                  May 2006   These fields can be reserved in any of the algorithms ofSection 4 by   replacing the line "set (requested_feedback_location, 0)" with the   following assembly:   :requested_feedback_location    pad (1)   :requested_feedback_length      pad (1)   :requested_feedback_field       pad (12)   :hash_start                     pad (8)   When a SigComp message is successfully decompressed and saved as   state, the following bytecode instructs the receiving endpoint to   return the first 6 bytes of the corresponding state identifier.  The   bytecode can be added to any of the compression algorithms ofSection4 immediately following the ":end_of_message" label:   :end_of_message   set (hash_length, (state_length + 8))   LOAD (requested_feedback_location, 1158)   MULTILOAD (hash_start, 4, state_length, 64,   decompress_sigcomp_message, 6)   SHA-1 (hash_start, hash_length, requested_feedback_field)   The receiving endpoint then returns the state identifier in the   "returned feedback field" of the next SigComp message to be   transmitted in the reverse direction.   When the state identifier is returned, the compressor can set the   availability flag for the corresponding state to 1.5.2.  Static Dictionary   Certain protocols that can be compressed using SigComp offer a fixed,   mandatory state item known as a static dictionary.  This dictionary   contains a number of text strings that commonly occur in messages   generated by the protocol in question.  The overall compression ratio   can often be improved by accessing the text phrases from this static   dictionary rather than by uploading them as part of the compressed   message.   As an example, a static dictionary is provided for the protocols SIP   and SDP,RFC 3485 [4].  This dictionary is designed for use by a wide   range of compression algorithms including all of the ones covered inSection 4.Surtees & West               Informational                     [Page 33]

RFC 4464                  SigComp Users' Guide                  May 2006   In any of the compression algorithms ofSection 4, the static   dictionary can be accessed by inserting the following instruction   immediately after the ":initialize_memory" label:   STATE-ACCESS (dictionary_id, 6, 0, 0, 1024, 0)   The parameters of STATE-ACCESS instruction will depend on the   compression algorithm in use.   The following lines should also be inserted immediately after the   END-MESSAGE instruction:   :dictionary_id   byte (0xfb, 0xe5, 0x07, 0xdf, 0xe5, 0xe6)   The text strings contained in the static dictionary can then be   accessed in exactly the same manner as the text strings from   previously decompressed messages (seeSection 5.1 for further   details).   Note that in some cases it is sufficient to load only part of the   static dictionary into the UDVM memory.  Further information on the   contents of the SIP and SDP static dictionary can be found in the   relevant document,RFC 3485 [4].5.3.  CRC Checksum   The acknowledgement scheme ofSection 5.1 is designed to indicate the   successful decompression of a message.  However, it does not   guarantee that the decompressed message is identical to the original   message, since decompression of a corrupted message could succeed but   with some characters being incorrect.  This could lead to an   incorrect message being passed to the application or unexpected   contents of state to be stored.  In order to prevent this happening,   a CRC check could be used.   If an additional CRC check is required, then the following bytecode   can be inserted after the ":end_of_message" label:   INPUT-BYTES (2, index, !)   CRC ($index, 64, state_length, !)   The bytecode extracts a 2-byte CRC from the end of the SigComp   message and compares it with a CRC calculated over the UDVM memory.   Decompression failure occurs if the two CRC values do not match.Surtees & West               Informational                     [Page 34]

RFC 4464                  SigComp Users' Guide                  May 2006   A definition of the CRC polynomial used by the CRC instruction can be   found in SigComp [2].5.4.  Announcing Additional Resources   If a particular endpoint is able to offer more processing or memory   resources than the mandatory minimum, the SigComp feedback mechanism   can be used to announce that these resources are available to the   remote endpoint.  This may help to improve the overall compression   ratio between the two endpoints.   Additionally, if an endpoint has any pieces of state that may be   useful for the remote endpoint to reference, it can advertise the   identifiers for the states.  The remote endpoint can then make use of   any that it also knows about (i.e., knows the contents of), for   example, a dictionary or shared mode state (seeSection 5.5).   The values of the following SigComp parameters can be announced using   the SigComp advertisement mechanism:      cycles_per_bit      decompression_memory_size      state_memory_size      SigComp_version      state identifiersSurtees & West               Informational                     [Page 35]

RFC 4464                  SigComp Users' Guide                  May 2006   As explained in SigComp, in order to announce the values of these   parameters, the following fields must be reserved in the UDVM memory:     0   1   2   3   4   5   6   7   +---+---+---+---+---+---+---+---+   |  cpb  |    dms    |    sms    |  returned_parameters_location   +---+---+---+---+---+---+---+---+   |        SigComp_version        |   +---+---+---+---+---+---+---+---+   | length_of_partial_state_ID_1  |   +---+---+---+---+---+---+---+---+   |                               |   :  partial_state_identifier_1   :   |                               |   +---+---+---+---+---+---+---+---+           :               :   +---+---+---+---+---+---+---+---+   | length_of_partial_state_ID_n  |   +---+---+---+---+---+---+---+---+   |                               |   :  partial_state_identifier_n   :   |                               |   +---+---+---+---+---+---+---+---+   These fields can be reserved in any of the algorithms ofSection 4 by   replacing the line "set (returned_parameters_location, 0)" with the   following piece of assembly:   :adverts_len                    pad (1)   :adverts_len_lsb                pad (1)   :returned_parameters_location   pad (1)   :returned_sigcomp_version       pad (1)   :state_ids                      pad (x)   where x is enough space for the number state identifiers that the   endpoint wishes to advertise.   When a SigComp message is successfully decompressed and saved as   state, the following bytecode announces to the receiving endpoint   that additional resources and pieces of state are available at the   sending endpoint:   :end_of_message   LOAD (returned_parameters_location, N)   INPUT-BYTES (1, adverts_len_lsb, done)   INPUT-BYTES ($adverts_len, state_ids, done)Surtees & West               Informational                     [Page 36]

RFC 4464                  SigComp Users' Guide                  May 2006   :done   Note that the integer value "N" should be set equal to the amount of   resources available at the sending endpoint.  N should be expressed   as a 2-byte integer with the most significant bits corresponding to   the cycles_per_bit parameter and the least significant bits   corresponding to the SigComp_version parameter.   The length of the state identifiers followed by the state identifiers   in the format shown are appended to the end of the compressed   message.5.5.  Shared Compression   This section provides bytecode for implementing the SigComp shared   compression mechanism,RFC 3321 [3].  If two endpoints A and B are   communicating via SigComp, shared compression allows the messages   sent from Endpoint A to Endpoint B to be compressed relative to the   messages sent from Endpoint B to Endpoint A (and vice versa).  This   may improve the overall compression ratio by reducing the need to   transmit the same information in both directions.   As described inRFC 3321 [3], two steps must be taken to implement   shared compression at an endpoint.   First, it is necessary to announce to the remote endpoint that shared   compression is available.  This is done by announcing the state   identifier as an available piece of state.  This can be done using   the returned_parameters_location announcement as inSection 5.4.   Second, assuming that such an announcement is received from the   remote endpoint, then the state created by shared compression needs   to be accessed by the message sent in the opposite direction.  This   can be done in a similar way to accessing the static dictionary (seeSection 5.2), but using the appropriate state identifier, for   example, by using the INPUT-BYTES instruction as below:   :shared_state_id        pad (6)   :access_shared_state   INPUT-BYTES (6, shared_state_id, !)   STATE-ACCESS (shared_state_id, 6, 0, 0, $decompressed_start, 0)Surtees & West               Informational                     [Page 37]

RFC 4464                  SigComp Users' Guide                  May 20066.  Security Considerations   This document describes implementation options for the SigComp   protocol [2].  Consequently, the security considerations for this   document match those of SigComp.7.  Acknowledgements   Thanks to Richard Price, Carsten Bormann, Adam Roach, Lawrence   Conroy, Christian Schmidt, Max Riegel, Lars-Erik Jonsson, Jonathan   Rosenberg, Stefan Forsgren, Krister Svanbro, Miguel Garcia,   Christopher Clanton, Khiem Le, Ka Cheong Leung, and Zoltan Barczikay   for valuable input and review.   Special thanks to Pekka Pessi and Cristian Constantin, who served as   committed working group document reviewers.8.  Intellectual Property Right Considerations   The IETF has been notified of intellectual property rights claimed in   regard to some or all of the specification contained in this   document.  For more information consult the online list of claimed   rights.9.  Normative References   [1]   Crocker, D. and P. Overell, "Augmented BNF for Syntax         Specifications: ABNF",RFC 4234, October 2005.   [2]   Price, R., Bormann, C., Christoffersson, J., Hannu, H., Liu,         Z., and J. Rosenberg, "Signaling Compression (SigComp)",RFC3320, January 2003.   [3]   Hannu, H., Christoffersson, J., Forsgren, S., Leung, K.-C.,         Liu, Z., and R. Price, "Signaling Compression (SigComp) -         Extended Operations",RFC 3321, January 2003.   [4]   Garcia-Martin, M., Bormann, C., Ott, J., Price, R., and A.B.         Roach, "The Session Initiation Protocol (SIP) and Session         Description Protocol (SDP) Static Dictionary for Signaling         Compression (SigComp)",RFC 3485, February 2003.   [5]   Ziv, J. and A. Lempel, "A universal algorithm for sequential         data compression", IEEE 23:337-343, 1977.   [6]   Storer, J., "Data Compression: Methods and Theory", Computer         Science Press ISBN 0-88175-161-8, 1998.Surtees & West               Informational                     [Page 38]

RFC 4464                  SigComp Users' Guide                  May 2006   [7]   Nelson, M., "LZW Data Compression", Dr Dobb's Journal,         October 1989.   [8]   Deutsch, P., "DEFLATE Compressed Data Format Specification         version 1.3",RFC 1951, May 1996.   [9]  "Data Compression Procedures", ITU-T Recommendation V.44,         November 2000.Surtees & West               Informational                     [Page 39]

RFC 4464                  SigComp Users' Guide                  May 2006Appendix A.  UDVM Bytecode for the Compression Algorithms   The following sections list the UDVM bytecode generated for each   compression algorithm ofSection 4.   Note that the different assemblers can output different bytecode for   the same piece of assembly code, so a valid assembler can produce   results different from those presented below.  However, the following   bytecode should always generate the same decompressed messages on any   UDVM.A.1.  Well-known AlgorithmsA.1.1.  LZ77   0x0f86 0389 8d89 1588 8800 011c 0420 0d13 5051 2222 5051 16f5 2300   0x00bf c086 a08b 06A.1.2.  LZSS   0x0f86 04a0 c48d 00a0 c41e 2031 0209 00a0 ff8e 048c bfff 0117 508d   0x0f23 0622 2101 1321 0123 16e5 1d04 22e8 0611 030e 2463 1450 5123   0x2252 5116 9fd2 2300 00bf c086 a089 06A.1.3.  LZW   0x0f86 06a1 ce8d 00b1 8f01 a0ce 13a0 4903 2313 2501 2506 1201 1752   0x88f4 079f 681d 0a24 2508 1203 0612 b18f 1252 0321 0ea0 4801 0624   0x5013 a049 0323 1351 5025 2251 5016 9fde 2300 00bf c086 a09f 06A.1.4.  DEFLATE   0x0f86 7aa2 528d 05a2 5200 0300 0400 0500 0600 0700 0800 0900 0a01   0x0b01 0d01 0f01 1102 1302 1702 1b02 1f03 2303 2b03 3303 3b04 a043   0x04a0 5304 a063 04a0 7305 a083 05a0 a305 a0c3 05a0 e300 a102 0001   0x0002 0003 0004 0105 0107 0209 020d 0311 0319 0421 0431 05a0 4105   0xa061 06a0 8106 a0c1 07a1 0107 a181 08a2 0108 a301 09a4 0109 a601   0x0aa8 010a ac01 0bb0 010b b801 0c80 2001 0c80 3001 0d80 4001 0d80   0x6001 1d03 229f b41e 20a0 6504 0700 1780 4011 0130 a0bf 0000 a0c0   0xa0c7 8040 2901 a190 a1ff a090 1750 8040 1109 a046 1322 2101 1321   0x0123 169f d108 1004 1250 0422 1d51 229f d706 1251 1e20 9fcf 0105   0x001f 2f08 1004 1250 0426 1d53 26f6 0614 530e 2063 1454 5223 2250   0x5216 9f9e 2300 00bf c086 a1de 06Surtees & West               Informational                     [Page 40]

RFC 4464                  SigComp Users' Guide                  May 2006A.1.5.  LZJH   0x0f86 08a1 5b8d 0700 a15b 0706 b18f 1d01 24a0 c317 5201 1a31 311e   0x24a0 b802 0101 0102 0100 0100 1752 0107 a04e 1e1d 6524 f822 2501   0x0ea0 4602 13a0 4703 2713 2501 2416 9fcd 1d66 24e1 1752 03a0 639f   0xb808 0812 0306 12b1 8312 5203 210e a046 0106 2350 0e28 6713 a047   0x0327 1351 5024 2251 5016 9fa8 1e24 9fb1 0401 0101 0102 0103 0201   0x0101 0d03 0007 0517 520d 0d06 061d 0826 f706 1253 1351 5011 1351   0x5224 2251 5206 1250 1225 0154 169f 6617 5201 9fdb 070f 1c00 009e   0xce16 9f57 1d01 24fa 1752 0107 0d9e c206 2501 169f 6506 2601 169f   0x7623 0000 bfc0 86a0 8e06A.2.  Adapted AlgorithmsA.2.1.  Modified DEFLATE   0x0f86 04a1 d38d 00a1 d31e 20a1 4010 0500 0b2e 000c 0c88 011a 20a1   0x0101 a042 a044 2000 a045 a05e a061 00a0 5fa0 66a1 0800 a067 a067   0xa1ff 02a1 a0a1 aa23 00a1 aba1 d13a 00a1 d2a1 e1a1 1001 a3c4 a3e3   0xa120 03bf 20bf 34a0 7b00 bf35 bfb3 a180 0180 3f68 803f 8700 0080   0x3f88 803f c7a1 4001 807f 9080 7fff a090 1750 88a0 79a0 83a0 831e   0x20a0 c810 0400 00a1 ff01 0209 8801 1416 2000 171e a108 013e a049   0x2e00 a04a a059 a110 02a1 68a1 81a0 6100 a182 a1a1 a120 01a3 44a3   0x6a3a 00a3 6ba3 aaa1 4001 a756 a760 2300 a761 a7df a180 01af c0af   0xd4a0 7b01 bfaa bfc9 0001 803f 9480 3ffb a090 0180 7ff8 807f ffa0   0xf817 5088 0610 1022 2101 1321 0123 169f 1107 10a0 fd1e 229f d909   0x0900 0709 0008 3fa0 8101 87a0 8701 00a0 88a0 f711 00a0 f8a1 3fa0   0xb901 a280 a57f a101 02b6 00b9 ffa4 0101 8034 0080 3bff a801 0290   0x00ff b001 0e24 6314 5150 2322 5250 169f 3b23 0000 bfc0 86a0 8906Surtees & West               Informational                     [Page 41]

RFC 4464                  SigComp Users' Guide                  May 2006Authors' Addresses   Abigail Surtees   Siemens/Roke Manor Research   Roke Manor Research Ltd.   Romsey, Hants  SO51 0ZN   UK   Phone: +44 (0)1794 833131   EMail: abigail.surtees@roke.co.uk   URI:http://www.roke.co.uk   Mark A. West   Siemens/Roke Manor Research   Roke Manor Research Ltd.   Romsey, Hants  SO51 0ZN   UK   Phone: +44 (0)1794 833311   EMail: mark.a.west@roke.co.uk   URI:http://www.roke.co.ukSurtees & West               Informational                     [Page 42]

RFC 4464                  SigComp Users' Guide                  May 2006Full Copyright Statement   Copyright (C) The Internet Society (2006).   This document is subject to the rights, licenses and restrictions   contained inBCP 78, and except as set forth therein, the authors   retain all their rights.   This document and the information contained herein are provided on an   "AS IS" basis and THE CONTRIBUTOR, THE ORGANIZATION HE/SHE REPRESENTS   OR IS SPONSORED BY (IF ANY), THE INTERNET SOCIETY AND THE INTERNET   ENGINEERING TASK FORCE DISCLAIM ALL WARRANTIES, EXPRESS OR IMPLIED,   INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE   INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED   WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.Intellectual Property   The IETF takes no position regarding the validity or scope of any   Intellectual Property Rights or other rights that might be claimed to   pertain to the implementation or use of the technology described in   this document or the extent to which any license under such rights   might or might not be available; nor does it represent that it has   made any independent effort to identify any such rights.  Information   on the procedures with respect to rights in RFC documents can be   found inBCP 78 andBCP 79.   Copies of IPR disclosures made to the IETF Secretariat and any   assurances of licenses to be made available, or the result of an   attempt made to obtain a general license or permission for the use of   such proprietary rights by implementers or users of this   specification can be obtained from the IETF on-line IPR repository athttp://www.ietf.org/ipr.   The IETF invites any interested party to bring to its attention any   copyrights, patents or patent applications, or other proprietary   rights that may cover technology that may be required to implement   this standard.  Please address the information to the IETF at   ietf-ipr@ietf.org.Acknowledgement   Funding for the RFC Editor function is provided by the IETF   Administrative Support Activity (IASA).Surtees & West               Informational                     [Page 43]

[8]ページ先頭

©2009-2025 Movatter.jp