Movatterモバイル変換


[0]ホーム

URL:


[RFC Home] [TEXT|PDF|HTML] [Tracker] [IPR] [Info page]

PROPOSED STANDARD
Network Working Group                                          J. PastorRequest for Comments: 3873                                  M. BelinchonCategory: Standards Track                                       Ericsson                                                          September 2004Stream Control Transmission Protocol (SCTP)Management Information Base (MIB)Status of this Memo   This document specifies an Internet standards track protocol for the   Internet community, and requests discussion and suggestions for   improvements.  Please refer to the current edition of the "Internet   Official Protocol Standards" (STD 1) for the standardization state   and status of this protocol.  Distribution of this memo is unlimited.Copyright Notice   Copyright (C) The Internet Society (2004).Abstract   The Stream Control Transmission Protocol (SCTP) is a reliable   transport protocol operating on top of a connectionless packet   network such as IP.  It is designed to transport public switched   telephone network (PSTN) signaling messages over the connectionless   packet network, but is capable of broader applications.   This memo defines the Management Information Base (MIB) module which   describes the minimum set of objects needed to manage the   implementation of the SCTP.Table of Contents1.  Introduction . . . . . . . . . . . . . . . . . . . . . . . . .21.1.  Abbreviations. . . . . . . . . . . . . . . . . . . . . .22.  The Internet-Standard Management Framework . . . . . . . . . .33.  MIB Structure. . . . . . . . . . . . . . . . . . . . . . . . .33.1.  SCTP Objects . . . . . . . . . . . . . . . . . . . . . .43.1.1.  SCTP Statistics. . . . . . . . . . . . . . . . .43.1.2.  SCTP Parameters. . . . . . . . . . . . . . . . .53.1.3.  MIB Tables . . . . . . . . . . . . . . . . . . .53.1.3.1.  Association Table. . . . . . . . . . .53.1.3.2.  Reverse Lookup Table . . . . . . . . .83.2.  Conformance. . . . . . . . . . . . . . . . . . . . . . .94.  Definitions. . . . . . . . . . . . . . . . . . . . . . . . . .9Pastor & Belinchon          Standards Track                     [Page 1]

RFC 3873                  SCTP MIB using SMIv2            September 20045.  Compiling Notes. . . . . . . . . . . . . . . . . . . . . . . .426.  References . . . . . . . . . . . . . . . . . . . . . . . . . .426.1.  Normative References . . . . . . . . . . . . . . . . . .426.2.  Informative References . . . . . . . . . . . . . . . . .437.  Security Considerations. . . . . . . . . . . . . . . . . . . .448.  Acknowledgments. . . . . . . . . . . . . . . . . . . . . . . .459.  Authors' Addresses . . . . . . . . . . . . . . . . . . . . . .4510. Full Copyright Statement . . . . . . . . . . . . . . . . . . .461.  Introduction   This memo defines the Management Information Base (MIB) module which   describes managed objects for implementations of the SCTP.   The document starts with a brief description of the SNMP framework   and continues with the MIB explanation and security consideration   sections among others.   The managed objects in this MIB module are based on [RFC2012] update:   "Management Information Base for the Transmission Control Protocol   (TCP)" referred as [TCPMIB] (work in progress), andRFC 3291 "Textual   Conventions for Internet Network Addresses" [RFC3291].   Terms related to the SCTP architecture are explained in [RFC2960].   Other specific abbreviations are listed below.   The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",   "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this   document are to be interpreted as described in [RFC2119].1.1.  Abbreviations   DNS   - Domain Name System   IANA  - Internet Assigned Numbers Authority   IETF  - Internet Engineering Task Force   IP    - Internet Protocol   MIB   - Management Information Base   RFC   - Request For Comments   RTO   - Retransmission Time Out   SCTP  - Stream Control Transmission Protocol   SMI   - Structure of Management Information   SNMP  - Simple Network Management Protocol   TCB   - Transmission Control Block   TCP   - Transmission Control ProtocolPastor & Belinchon          Standards Track                     [Page 2]

RFC 3873                  SCTP MIB using SMIv2            September 20042.  The Internet-Standard Management Framework   For a detailed overview of the documents that describe the current   Internet-Standard Management Framework, please refer tosection 7 of   RFC 3410 [RFC3410].   Managed objects are accessed via a virtual information store, termed   the Management Information Base or MIB.  MIB objects are generally   accessed through the Simple Network Management Protocol (SNMP).   Objects in the MIB are defined using the mechanisms defined in the   Structure of Management Information (SMI).  This memo specifies a MIB   module that is compliant to the SMIv2, which is described in STD 58,RFC 2578 [RFC2578], STD 58,RFC 2579 [RFC2579] and STD 58,RFC 2580   [RFC2580].3.  MIB Structure   This chapter explains the main objects this MIB defines.  A detailed   view of the MIB structure with the OID values is below.   MIB-2 {1 3 6 1 2 1}     +--(104)sctpMIB          |          +--(1) sctpObjects          |   |          |   +--(1) sctpStats          |   |   |          |   |   +-- <scalars>          |   |          |   +--(2)sctpParameters          |   |   |          |   |   +-- <scalars>          |   |          |   +--(3) sctpAssocTable          |   |          |   +--(4) sctpAssocLocalAddrTable          |   |          |   +--(5) sctpAssocRemAddrTable          |   |          |   +--(6) sctpLookupLocalPortTable          |   |          |   +--(7) sctpLookupRemPortTable          |   |          |   +--(8) sctpLookupRemHostNameTable          |   |          |   +--(9) sctpLookupRemPrimIPAddrTable          |   |          |   +--(10) sctpLookupRemIPAddrTablePastor & Belinchon          Standards Track                     [Page 3]

RFC 3873                  SCTP MIB using SMIv2            September 2004          |          |          +--(2)sctpMibConformance              |              +--(1) sctpMibCompliances              |   |              |   +--(1) sctpMibCompliance              |              +--(2) sctpMibGroups                  |                  +--(1) sctpLayerParamsGroup                  |                  +--(2) sctpStatsGroup                  |                  +--(3) sctpPerAssocParamsGroup                  |                  +--(4) sctpInverseGroup   The main groups are explained further in the MIB definition.3.1.  SCTP Objects   This branch contains the SCTP statistics and general parameters (both   of them scalars) and the SCTP MIB tables.3.1.1.  SCTP Statistics   The SCTP MIB includes both Counter32s and Counter64s to deal with   statistics.  Counter64s are used for those counters, which are likely   to wrap around in less than one hour, according to [RFC2863].   In addition Gauge32 is also used.3.1.1.1.  State-Related Statistics   These statistics are based on the TCP model, but adapted to the SCTP   states.  They store the number of successful association attempts,   how many associations have been initiated by the local or the remote   SCTP layer, and the number of associations terminated in a graceful   (by means of SHUTDOWN procedure) or ungraceful way (by means of CLOSE   procedure).3.1.1.2.  Statistics for traffic Measurements   This set of objects specifies statistics related to the whole SCTP   layer.  There are, e.g., statistics related to both SCTP packets and   SCTP chunks.Pastor & Belinchon          Standards Track                     [Page 4]

RFC 3873                  SCTP MIB using SMIv2            September 2004   Statistics related to a specific association, or local/remote IP   addresses are defined inside their associated table.3.1.2.  SCTP Parameters   This section of the MIB contains the general variables for the SCTP   protocol.  Maximum, minimum, initial and default values are listed   here.   SCTP RTO mechanism definition is based on the TCP MIB [TCPMIB].  In   SCTP, only options 'other' and 'vanj' are valid since SCTP defines   Van Jacobson's algorithm (vanj) as the one to be used to calculate   RTO. 'Other' is left for future use.3.1.3.  MIB Tables   There are several tables included in the SCTP MIB.  The first group   deals with the SCTP association variables and is composed of a main   and two extended tables.  The second group is a bunch of tables used   to perform reverse lookups.   It is NOT possible to create rows in any table (sctpAssocTable,   sctpAssocLocalAddrTable, sctpRemAddrTable and Reverse Lookup tables)   using SNMP.   It is NOT possible to delete rows in any table using SNMP except in   sctpAssocTable under the particular conditions explained below.3.1.3.1.  Association Table   The sctpAssocTable  is the main MIB table, where all the association   related information is stored on a per association basis.  It is   structured according to expanded tables.  The main table is called   sctpAssocTable and is indexed by sctpAssocId (the association   identification).  This is a value that uniquely identifies an   association.  The MIB does not restrict what value must be written   here, however it must be unique within the table.   The sctpAssoc index is also shared by two more tables:      -  sctpAssocLocalAddrTable: to store the local IP address(es).      -  sctpAssocRemAddrTable: to store the remote addresses and the         per-remote-address related information.   Entries in the sctpAssocTable are created when trying to establish   the association, i.e., when sending the COOKIE-ECHO message   (originating side) or the COOKIE-ACK message (server side).  At this   point, i.e., at established state, all entry fields are filled in   with valid values.Pastor & Belinchon          Standards Track                     [Page 5]

RFC 3873                  SCTP MIB using SMIv2            September 2004   Note: The following representation is a conceptual mode of describing   the relationship between the tables in this MIB.  Note that the real   relationship of the tables is by sharing an index, so tables are not   truly within tables.  Every entry is explained when defining the   corresponding objects in the MIB.   mib-2 {1 3 6 1 2 1}     +--(104)sctpMIB          |          +--(1) sctpObjects          |   |          .   .          .   .              |              +--(3) sctpAssocTable              |   |              |   +--(1) sctpAssocId (index)              |   |              |   +--(2) sctpAssocRemHostName              |   |              |   +--(3) sctpAssocLocalPort              |   |              |   +--(4) sctpAssocRemPort              |   |              |   +--(5) sctpAssocRemPrimAddrType              |   |              |   +--(6) sctpAssocRemPrimAddr              |   |              |   +--(7) sctpAssocHeartBeatInterval              |   |              |   +--(8) sctpAssocState              |   |              |   +--(9) sctpAssocInStreams              |   |              |   +--(10) sctpAssocOutStreams              |   |              |   +--(11) sctpAssocMaxRetr              |   |              |   +--(12) sctpAssocPrimProcess              |   |              |   +--(13) sctpAssocT1expireds              |   |              |   +--(14) sctpAssocT2expireds              |   |              |   +--(15) sctpAssocRtxChunks              |   |              |   +--(16) sctpAssocStartTime              |   |Pastor & Belinchon          Standards Track                     [Page 6]

RFC 3873                  SCTP MIB using SMIv2            September 2004              |   +--(17) sctpAssocDiscontinuityTime              |              |              +--(4) sctpAssocLocalAddrTable              |   |              |   |--(-) sctpAssocId (shared index)              |   |              |   +--(1) sctpAssocLocalAddrType(index)              |   |              |   +--(2) sctpAssocLocalAddr (index)              |   |              |   +--(3) sctpAssocLocalAddrStartTime              |              |              +--(5) sctpAssocRemAddrTable              |   |              |   |--(-) sctpAssocId (shared index)              |   |              |   +--(1) sctpAssocRemAddrType (index)              .   |              .   +--(2) sctpAssocRemAddr (index)              .   |                  +--(3) sctpAssocRemAddrActive                  |                  +--(4) sctpAssocRemAddrHBActive                  |                  +--(5) sctpAssocRemAddrRTO                  |                  +--(6) sctpAssocRemAddrMaxPathRtx                  |                  +--(7) sctpAssocRemAddrRtx                  |                  +--(8) sctpAssocRemAddrStartTime   Both sctpAssocLocalAddrTable and sctpAssocRemAddrTable are indexed by   addresses.  'Addr' and 'AddrType' use the syntax InetAddress and   InetAddressType defined in the Textual Conventions for Internet   Network Address (RFC3291).  The InetAddressType TC has codepoints for   unknown, IPv4, IPv6, non-global IPv4, non-global IPv6, and DNS   addresses, but only the IPv4 and IPv6 address types are required to   be supported by implementations of this MIB module.  Implementations   that connect multiple zones are expected to support the non-global   IPv4 and non-global IPv6 address types as well.   Note that DNS addresses are not used in this MIB module.  They are   always resolved to the on-the-wire form prior to connection setup,   and the on-the-wire form is what appears in the MIB objects.Pastor & Belinchon          Standards Track                     [Page 7]

RFC 3873                  SCTP MIB using SMIv2            September 2004   The sctpAssocLocalAddrTable table will have as many entries as local   IP addresses have been defined for the association.  The   sctpAssocRemAddrTable table will contain as many entries as remote IP   addresses are known to reach the peer.  For the multihoming concept   see referenceRFC2960.   To keep the name of the remote peer (when provided by the peer at   initialization time), an entry has been created in the sctpAssocTable   called sctpAssocRemHostName.  When no DNS name is provided by the   remote endpoint, this value will be NULL (zero-length string).   Otherwise, the received DNS name will be stored here.   If it is necessary to abort an existing association, the value   deleteTCB(9) must be written in the variable sctpAssocState.  That is   the only way to delete rows in any of the mentioned tables.3.1.3.2.  Reverse Lookup Table   There are five reverse lookup tables to help management applications   efficiently access conceptual rows in other tables.  These tables   allow management applications to avoid expensive tree walks through   large numbers of associations.   All of these tables are optional.  If these tables are implemented,   an entry in them must be created after the entry in the main table   (sctpAssocTable) associated with it has been created.  This ensures   that the field indexing the lookup table exists.   The defined reverse lookup tables allow for performing a lookup using   the following variables:      -  Local Port: It allows a management application to find all the         associations that use a specific local port      -  Remote Port: It allows a management application to find all the         associations that use a specific remote port      -  Remote Host Name: It allows a management application to find         all the associations with a specific host name.      -  Remote Primary IP Address: It allows a management application         to find all the associations that use a specific remote IP         address as primary.      -  Remote IP address: a management application to find all the          associations that use a specific remote IP address.   As an example the picture below shows the table to look up by local   port.Pastor & Belinchon          Standards Track                     [Page 8]

RFC 3873                  SCTP MIB using SMIv2            September 2004   MIB-2 {1 3 6 1 2 1}     +--(104)sctpMIB          |          +--(1) sctpObjects          |   |          .   .          .   .          |   |          |   +--(6) sctpLookupLocalPortTable          |   |   |          .   .   +--(-) sctpAssocLocalPort (shared index)          .   .   |                  +--(-) sctpAssocId (shared index)                  |                  +--(1) sctpLookupLocalPortStartTime   It is not possible for the operator to either create or delete rows   in these tables.  The rows in this table will dynamically appear and   be removed as the corresponding entries in sctpAssocTable are.3.2.  Conformance   The conformance section recommends all the inverse lookup tables in   this MIB as optional.  General layer and per association parameters   and statistics are considered mandatory.   IP addresses use the global IPv4 and global IPv6 address formats.   Unknown value and DNS name formats are not used.  Names, if present,   are stored in the sctpRemoteHostName variable.4.  Definitions   SCTP-MIB DEFINITIONS ::= BEGIN   IMPORTS     MODULE-IDENTITY, OBJECT-TYPE, Integer32, Unsigned32, Gauge32,     Counter32, Counter64, mib-2          FROM SNMPv2-SMI                        -- [RFC2578]     TimeStamp, TruthValue          FROM SNMPv2-TC                         -- [RFC2579]     MODULE-COMPLIANCE, OBJECT-GROUP          FROM SNMPv2-CONF                       -- [RFC2580]     InetAddressType, InetAddress, InetPortNumber          FROM INET-ADDRESS-MIB;                 -- [RFC3291]Pastor & Belinchon          Standards Track                     [Page 9]

RFC 3873                  SCTP MIB using SMIv2            September 2004   sctpMIB MODULE-IDENTITY     LAST-UPDATED "200409020000Z"       -- 2nd September 2004     ORGANIZATION "IETF SIGTRAN Working Group"     CONTACT-INFO          "           WG EMail: sigtran@ietf.org           Web Page:http://www.ietf.org/html.charters/sigtran-charter.html           Chair:     Lyndon Ong                      Ciena Corporation                      0480 Ridgeview Drive                      Cupertino, CA  95014                      USA                      Tel:                      Email: lyong@ciena.com           Editors:   Maria-Carmen Belinchon                      R&D Department                      Ericsson Espana S. A.                      Via de los Poblados, 13                      28033 Madrid                      Spain                      Tel:   +34 91 339 3535                      Email: Maria.C.Belinchon@ericsson.com                      Jose-Javier Pastor-Balbas                      R&D Department                      Ericsson Espana S. A.                      Via de los Poblados, 13                      28033 Madrid                      Spain                      Tel:   +34 91 339 1397               Email: J.Javier.Pastor@ericsson.com          "     DESCRIPTION          "The MIB module for managing SCTP implementations.          Copyright (C) The Internet Society (2004).  This version of          this MIB module is part ofRFC 3873; see the RFC itself for          full legal notices. "     REVISION "200409020000Z"       -- 2nd September 2004     DESCRIPTION " Initial version, published asRFC 3873"     ::= {  mib-2 104 }Pastor & Belinchon          Standards Track                    [Page 10]

RFC 3873                  SCTP MIB using SMIv2            September 2004   -- the SCTP base variables group   sctpObjects OBJECT IDENTIFIER ::= { sctpMIB 1 }   sctpStats   OBJECT IDENTIFIER ::= { sctpObjects 1 }   sctpParams  OBJECT IDENTIFIER ::= { sctpObjects 2 }   -- STATISTICS   -- **********   -- STATE-RELATED STATISTICS   sctpCurrEstab OBJECT-TYPE     SYNTAX         Gauge32     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The number of associations for which the current state is          either ESTABLISHED, SHUTDOWN-RECEIVED or SHUTDOWN-PENDING."     REFERENCE          "Section 4 in RFC2960 covers the SCTP   Association state          diagram."     ::= { sctpStats 1 }   sctpActiveEstabs OBJECT-TYPE     SYNTAX         Counter32     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The number of times that associations have made a direct          transition to the ESTABLISHED state from the COOKIE-ECHOED          state: COOKIE-ECHOED -> ESTABLISHED. The upper layer initiated          the association attempt."     REFERENCE          "Section 4 in RFC2960 covers the SCTP   Association state          diagram."     ::= { sctpStats  2 }Pastor & Belinchon          Standards Track                    [Page 11]

RFC 3873                  SCTP MIB using SMIv2            September 2004   sctpPassiveEstabs OBJECT-TYPE     SYNTAX         Counter32     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The number of times that associations have made a direct          transition to the ESTABLISHED state from the CLOSED state:          CLOSED -> ESTABLISHED. The remote endpoint initiated the          association attempt."     REFERENCE          "Section 4 in RFC2960 covers the SCTP   Association state          diagram."     ::= { sctpStats  3 }   sctpAborteds OBJECT-TYPE     SYNTAX         Counter32     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The number of times that associations have made a direct          transition to the CLOSED state from any state using the          primitive 'ABORT': AnyState --Abort--> CLOSED. Ungraceful          termination of the association."     REFERENCE          "Section 4 in RFC2960 covers the SCTP   Association state          diagram."     ::= { sctpStats  4 }   sctpShutdowns OBJECT-TYPE     SYNTAX         Counter32     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The number of times that associations have made a direct          transition to the CLOSED state from either the SHUTDOWN-SENT          state or the SHUTDOWN-ACK-SENT state. Graceful termination of          the association."     REFERENCE          "Section 4 in RFC2960 covers the SCTP   Association state          diagram."     ::= { sctpStats  5 }Pastor & Belinchon          Standards Track                    [Page 12]

RFC 3873                  SCTP MIB using SMIv2            September 2004   -- OTHER LAYER STATISTICS   sctpOutOfBlues OBJECT-TYPE     SYNTAX         Counter32     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The number of out of the blue packets received by the host.          An out of the blue packet is an SCTP packet correctly formed,          including the proper checksum, but for which the receiver was          unable to identify an appropriate association."     REFERENCE          "Section 8.4 in RFC2960 deals with the Out-Of-The-Blue           (OOTB) packet definition and procedures."     ::= { sctpStats  6 }   sctpChecksumErrors OBJECT-TYPE     SYNTAX         Counter32     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The number of SCTP packets received with an invalid          checksum."     REFERENCE          "The checksum is located at the end of the SCTP packet as perSection 3.1 in RFC2960.RFC3309 updates SCTP to use a 32 bit          CRC checksum."   ::= { sctpStats  7 }   sctpOutCtrlChunks OBJECT-TYPE     SYNTAX         Counter64     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The number of SCTP control chunks sent (retransmissions are          not included). Control chunks are those chunks different from          DATA."     REFERENCE          "Sections1.3.5 and1.4 inRFC2960 refer to control chunk as          those chunks different from those that contain user          information, i.e., DATA chunks."     ::= { sctpStats  8 }Pastor & Belinchon          Standards Track                    [Page 13]

RFC 3873                  SCTP MIB using SMIv2            September 2004   sctpOutOrderChunks OBJECT-TYPE     SYNTAX         Counter64     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The number of SCTP ordered data chunks sent (retransmissions          are not included)."     REFERENCE          "Section 3.3.1 in RFC2960 defines the ordered data chunk."     ::= { sctpStats  9 }   sctpOutUnorderChunks OBJECT-TYPE     SYNTAX         Counter64     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The number of SCTP unordered chunks (data chunks in which the          U bit is set to 1) sent (retransmissions are not included)."     REFERENCE          "Section 3.3.1 in RFC2960 defines the unordered data chunk."     ::= { sctpStats  10 }   sctpInCtrlChunks OBJECT-TYPE     SYNTAX         Counter64     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The number of SCTP control chunks received (no duplicate          chunks included)."     REFERENCE          "Sections1.3.5 and1.4 inRFC2960 refer to control chunk as          those chunks different from those that contain user          information, i.e., DATA chunks."     ::= { sctpStats  11 }   sctpInOrderChunks OBJECT-TYPE     SYNTAX         Counter64     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The number of SCTP ordered data chunks received (no duplicate          chunks included)."Pastor & Belinchon          Standards Track                    [Page 14]

RFC 3873                  SCTP MIB using SMIv2            September 2004     REFERENCE          "Section 3.3.1 in RFC2960 defines the ordered data chunk."     ::= { sctpStats  12 }   sctpInUnorderChunks OBJECT-TYPE     SYNTAX         Counter64     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The number of SCTP unordered chunks (data chunks in which the          U bit is set to 1) received (no duplicate chunks included)."     REFERENCE          "Section 3.3.1 in RFC2960 defines the unordered data chunk."     ::= { sctpStats  13 }   sctpFragUsrMsgs OBJECT-TYPE     SYNTAX         Counter64     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The number of user messages that have to be fragmented          because of the MTU."     ::= { sctpStats  14 }   sctpReasmUsrMsgs OBJECT-TYPE     SYNTAX         Counter64     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The number of user messages reassembled, after conversion          into DATA chunks."     REFERENCE          "Section 6.9 in RFC2960 includes a description of the          reassembly process."     ::= { sctpStats  15 }Pastor & Belinchon          Standards Track                    [Page 15]

RFC 3873                  SCTP MIB using SMIv2            September 2004   sctpOutSCTPPacks OBJECT-TYPE     SYNTAX         Counter64     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The number of SCTP packets sent. Retransmitted DATA chunks          are included."     ::= { sctpStats  16 }   sctpInSCTPPacks OBJECT-TYPE     SYNTAX         Counter64     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The number of SCTP packets received. Duplicates are          included."     ::= { sctpStats  17 }   sctpDiscontinuityTime OBJECT-TYPE     SYNTAX         TimeStamp     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The value of sysUpTime on the most recent occasion at which          any one or more of this general statistics counters suffered a          discontinuity.  The relevant counters are the specific          instances associated with this interface of any Counter32 or          Counter64 object contained in the SCTP layer statistics          (defined below sctpStats branch).  If no such discontinuities          have occurred since the last re-initialization of the local          management subsystem, then this object contains a zero value."     REFERENCE          "The inclusion of this object is recommended byRFC2578."     ::= { sctpStats 18 }   -- PROTOCOL GENERAL VARIABLES   -- **************************   sctpRtoAlgorithm OBJECT-TYPE     SYNTAX         INTEGER {                         other(1),      -- Other new one. Future use                         vanj(2)        -- Van Jacobson's algorithm                    }Pastor & Belinchon          Standards Track                    [Page 16]

RFC 3873                  SCTP MIB using SMIv2            September 2004     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The algorithm used to determine the timeout value (T3-rtx)          used for re-transmitting unacknowledged chunks."     REFERENCE          "Section 6.3.1 and 6.3.2 inRFC2960 cover the RTO calculation          and retransmission timer rules."     DEFVAL {vanj} -- vanj(2)     ::= { sctpParams 1 }   sctpRtoMin OBJECT-TYPE     SYNTAX         Unsigned32     UNITS          "milliseconds"     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The minimum value permitted by a SCTP implementation for the          retransmission timeout value, measured in milliseconds.  More          refined semantics for objects of this type depend upon the          algorithm used to determine the retransmission timeout value.          A retransmission time value of zero means immediate          retransmission.          The value of this object has to be lower than or equal to          stcpRtoMax's value."     DEFVAL {1000} -- milliseconds     ::= { sctpParams 2 }   sctpRtoMax OBJECT-TYPE     SYNTAX         Unsigned32     UNITS          "milliseconds"     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The maximum value permitted by a SCTP implementation for the          retransmission timeout value, measured in milliseconds.  More          refined semantics for objects of this type depend upon the          algorithm used to determine the retransmission timeout value.          A retransmission time value of zero means immediate re-          transmission.Pastor & Belinchon          Standards Track                    [Page 17]

RFC 3873                  SCTP MIB using SMIv2            September 2004          The value of this object has to be greater than or equal to          stcpRtoMin's value."     DEFVAL {60000} -- milliseconds       ::= { sctpParams 3 }   sctpRtoInitial OBJECT-TYPE     SYNTAX         Unsigned32     UNITS          "milliseconds"     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The initial value for the retransmission timer.          A retransmission time value of zero means immediate re-          transmission."     DEFVAL {3000} -- milliseconds     ::= { sctpParams 4 }   sctpMaxAssocs OBJECT-TYPE     SYNTAX         Integer32 (-1 | 0..2147483647)     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The limit on the total number of associations the entity can          support. In entities where the maximum number of associations          is dynamic, this object should contain the value -1."     ::= { sctpParams 5 }   sctpValCookieLife OBJECT-TYPE     SYNTAX         Unsigned32     UNITS          "milliseconds"     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "Valid cookie life in the 4-way start-up handshake procedure."     REFERENCE          "Section 5.1.3 in RFC2960 explains the cookie generation          process. Recommended value is persection 14 in RFC2960."     DEFVAL {60000} -- milliseconds     ::= { sctpParams 6 }Pastor & Belinchon          Standards Track                    [Page 18]

RFC 3873                  SCTP MIB using SMIv2            September 2004   sctpMaxInitRetr OBJECT-TYPE     SYNTAX         Unsigned32     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The maximum number of retransmissions at the start-up phase          (INIT and COOKIE ECHO chunks). "     REFERENCE          "Section 5.1.4, 5.1.6 inRFC2960 refers to Max.Init.Retransmit          parameter. Recommended value is persection 14 in RFC2960."     DEFVAL {8} -- number of attempts     ::= { sctpParams 7 }   -- TABLES   -- ******   -- the SCTP Association TABLE   -- The SCTP association table contains information about each   -- association in which the local endpoint is involved.   sctpAssocTable OBJECT-TYPE     SYNTAX         SEQUENCE OF SctpAssocEntry     MAX-ACCESS     not-accessible     STATUS         current     DESCRIPTION          "A table containing SCTP association-specific information."     ::= { sctpObjects 3 }   sctpAssocEntry OBJECT-TYPE     SYNTAX         SctpAssocEntry     MAX-ACCESS     not-accessible     STATUS         current     DESCRIPTION          "General common variables and statistics for the whole          association."     INDEX          { sctpAssocId }     ::= { sctpAssocTable 1 }Pastor & Belinchon          Standards Track                    [Page 19]

RFC 3873                  SCTP MIB using SMIv2            September 2004   SctpAssocEntry ::= SEQUENCE {     sctpAssocId                        Unsigned32,     sctpAssocRemHostName               OCTET STRING,     sctpAssocLocalPort                 InetPortNumber,     sctpAssocRemPort                   InetPortNumber,     sctpAssocRemPrimAddrType           InetAddressType,     sctpAssocRemPrimAddr               InetAddress,     sctpAssocHeartBeatInterval         Unsigned32,     sctpAssocState                     INTEGER,     sctpAssocInStreams                 Unsigned32,     sctpAssocOutStreams                Unsigned32,     sctpAssocMaxRetr                   Unsigned32,     sctpAssocPrimProcess               Unsigned32,     sctpAssocT1expireds                Counter32,     -- Statistic     sctpAssocT2expireds                Counter32,     -- Statistic     sctpAssocRtxChunks                 Counter32,     -- Statistic     sctpAssocStartTime                 TimeStamp,     sctpAssocDiscontinuityTime         TimeStamp     }   sctpAssocId OBJECT-TYPE     SYNTAX         Unsigned32 (1..4294967295)     MAX-ACCESS     not-accessible     STATUS         current     DESCRIPTION          "Association Identification. Value identifying the          association. "     ::= { sctpAssocEntry 1 }   sctpAssocRemHostName OBJECT-TYPE     SYNTAX         OCTET STRING (SIZE(0..255))     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The peer's DNS name. This object needs to have the same          format as the encoding in the DNS protocol.  This implies that          the domain name can be up to 255 octets long, each octet being          0<=x<=255 as value with US-ASCII A-Z having a case insensitive          matching.          If no DNS domain name was received from the peer at init time          (embedded in the INIT or INIT-ACK chunk), this object is          meaningless. In such cases the object MUST contain a zero-          length string value. Otherwise, it contains the remote host          name received at init time."Pastor & Belinchon          Standards Track                    [Page 20]

RFC 3873                  SCTP MIB using SMIv2            September 2004     ::= { sctpAssocEntry 2 }   sctpAssocLocalPort OBJECT-TYPE     SYNTAX         InetPortNumber (1..65535)     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The local SCTP port number used for this association."     ::= { sctpAssocEntry 3 }   sctpAssocRemPort OBJECT-TYPE     SYNTAX         InetPortNumber (1..65535)     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The remote SCTP port number used for this association."     ::= { sctpAssocEntry 4 }   sctpAssocRemPrimAddrType OBJECT-TYPE     SYNTAX         InetAddressType     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The internet type of primary remote IP address. "     ::= { sctpAssocEntry 5 }   sctpAssocRemPrimAddr OBJECT-TYPE     SYNTAX         InetAddress     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The primary remote IP address. The type of this address is          determined by the value of sctpAssocRemPrimAddrType.          The client side will know this value after INIT_ACK message          reception, the server side will know this value when sending          INIT_ACK message. However, values will be filled in at          established(4) state."     ::= { sctpAssocEntry 6 }Pastor & Belinchon          Standards Track                    [Page 21]

RFC 3873                  SCTP MIB using SMIv2            September 2004   sctpAssocHeartBeatInterval OBJECT-TYPE     SYNTAX         Unsigned32     UNITS          "milliseconds"     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The current heartbeat interval..          Zero value means no HeartBeat, even when the concerned          sctpAssocRemAddrHBFlag object is true."     DEFVAL {30000} -- milliseconds     ::= { sctpAssocEntry 7 }   sctpAssocState OBJECT-TYPE     SYNTAX         INTEGER {                         closed(1),                         cookieWait(2),                         cookieEchoed(3),                         established(4),                         shutdownPending(5),                         shutdownSent(6),                         shutdownReceived(7),                         shutdownAckSent(8),                         deleteTCB(9)                         }     MAX-ACCESS     read-write     STATUS         current     DESCRIPTION          "The state of this SCTP association.          As in TCP, deleteTCB(9) is the only value that may be set by a          management station. If any other value is received, then the          agent must return a wrongValue error.          If a management station sets this object to the value          deleteTCB(9), then this has the effect of deleting the TCB (as          defined in SCTP) of the corresponding association on the          managed node, resulting in immediate termination of the          association.          As an implementation-specific option, an ABORT chunk may be          sent from the managed node to the other SCTP endpoint as a          result of setting the deleteTCB(9) value. The ABORT chunk          implies an ungraceful association shutdown."Pastor & Belinchon          Standards Track                    [Page 22]

RFC 3873                  SCTP MIB using SMIv2            September 2004     REFERENCE          "Section 4 in RFC2960 covers the SCTP Association state          diagram."     ::= { sctpAssocEntry 8 }   sctpAssocInStreams OBJECT-TYPE     SYNTAX         Unsigned32 (1..65535)     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "Inbound Streams according to the negotiation at association          start up."     REFERENCE          "Section 1.3 in RFC2960 includes a definition of stream.Section 5.1.1 in RFC2960 covers the streams negotiation          process."     ::= { sctpAssocEntry 9 }   sctpAssocOutStreams OBJECT-TYPE     SYNTAX         Unsigned32 (1..65535)     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "Outbound Streams according to the negotiation at association          start up. "     REFERENCE          "Section 1.3 in RFC2960 includes a definition of stream.Section 5.1.1 in RFC2960 covers the streams negotiation          process."     ::= { sctpAssocEntry 10 }   sctpAssocMaxRetr OBJECT-TYPE     SYNTAX         Unsigned32     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The maximum number of data retransmissions in the association          context. This value is specific for each association and the          upper layer can change it by calling the appropriate          primitives. This value has to be smaller than the addition of          all the maximum number for all the paths          (sctpAssocRemAddrMaxPathRtx).Pastor & Belinchon          Standards Track                    [Page 23]

RFC 3873                  SCTP MIB using SMIv2            September 2004          A value of zero value means no retransmissions."     DEFVAL {10} -- number of attempts     ::= { sctpAssocEntry 11 }   sctpAssocPrimProcess OBJECT-TYPE         SYNTAX      Unsigned32         MAX-ACCESS read-only         STATUS      current         DESCRIPTION          "This object identifies the system level process which holds          primary responsibility for the SCTP association.          Wherever possible, this should be the system's native unique          identification number. The special value 0 can be used to          indicate that no primary process is known.          Note that the value of this object can be used as a pointer          into the swRunTable of the HOST-RESOURCES-MIB(if the value is          smaller than 2147483647) or into the sysApplElmtRunTable of          the SYSAPPL-MIB."     ::= { sctpAssocEntry 12 }   -- Association Statistics   sctpAssocT1expireds OBJECT-TYPE     SYNTAX         Counter32     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The T1 timer determines how long to wait for an          acknowledgement after sending an INIT or COOKIE-ECHO chunk.          This object reflects the number of times the T1 timer expires          without having received the acknowledgement.          Discontinuities in the value of this counter can occur at re-          initialization of the management system, and at other times as          indicated by the value of sctpAssocDiscontinuityTime."     REFERENCE          "Section 5 in RFC2960."     ::= { sctpAssocEntry 13 }   sctpAssocT2expireds OBJECT-TYPE     SYNTAX         Counter32     MAX-ACCESS     read-onlyPastor & Belinchon          Standards Track                    [Page 24]

RFC 3873                  SCTP MIB using SMIv2            September 2004     STATUS         current     DESCRIPTION          "The T2 timer determines how long to wait for an          acknowledgement after sending a SHUTDOWN or SHUTDOWN-ACK          chunk. This object reflects the number of times that T2- timer          expired.          Discontinuities in the value of this counter can occur at re-          initialization of the management system, and at other times as          indicated by the value of sctpAssocDiscontinuityTime."   REFERENCE          "Section 9.2 in RFC2960."     ::= { sctpAssocEntry 14 }   sctpAssocRtxChunks OBJECT-TYPE     SYNTAX         Counter32     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "When T3-rtx expires, the DATA chunks that triggered the T3          timer will be re-sent according with the retransmissions          rules. Every DATA chunk that was included in the SCTP packet          that triggered the T3-rtx timer must be added to the value of          this counter.          Discontinuities in the value of this counter can occur at re-          initialization of the management system, and at other times as          indicated by the value of sctpAssocDiscontinuityTime."     REFERENCE          "Section 6 in RFC2960 covers the retransmission process and          rules."     ::= { sctpAssocEntry 15 }   sctpAssocStartTime OBJECT-TYPE     SYNTAX         TimeStamp     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The value of sysUpTime at the time that the association          represented by this row enters the ESTABLISHED state, i.e.,          the sctpAssocState object is set to established(4). The          value of this object will be zero:          - before the association enters the established(4)            state, orPastor & Belinchon          Standards Track                    [Page 25]

RFC 3873                  SCTP MIB using SMIv2            September 2004          - if the established(4) state was entered prior to            the last re-initialization of the local network management            subsystem."     ::= { sctpAssocEntry 16 }   sctpAssocDiscontinuityTime OBJECT-TYPE     SYNTAX         TimeStamp     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The value of sysUpTime on the most recent occasion at which          any one or more of this SCTP association counters suffered a          discontinuity.  The relevant counters are the specific          instances associated with this interface of any Counter32 or          Counter64 object contained in the sctpAssocTable or          sctpLocalAddrTable or sctpRemAddrTable.  If no such          discontinuities have occurred since the last re-initialization          of the local management subsystem, then this object contains a          zero value. "     REFERENCE          "The inclusion of this object is recommended byRFC2578."     ::= { sctpAssocEntry 17 }   -- Expanded tables: Including Multi-home feature   -- Local Address TABLE   -- *******************   sctpAssocLocalAddrTable OBJECT-TYPE     SYNTAX         SEQUENCE OF SctpAssocLocalAddrEntry     MAX-ACCESS     not-accessible     STATUS         current     DESCRIPTION          "Expanded table of sctpAssocTable based on the AssocId index.          This table shows data related to each local IP address which          is used by this association."     ::= { sctpObjects  4 }   sctpAssocLocalAddrEntry OBJECT-TYPE     SYNTAX         SctpAssocLocalAddrEntry     MAX-ACCESS     not-accessible     STATUS         current     DESCRIPTION          "Local information about the available addresses. There will          be an entry for every local IP address defined for thisPastor & Belinchon          Standards Track                    [Page 26]

RFC 3873                  SCTP MIB using SMIv2            September 2004          association.          Implementors need to be aware that if the size of          sctpAssocLocalAddr exceeds 114 octets then OIDs of column          instances in this table will have more than 128 sub-          identifiers and cannot be accessed using SNMPv1, SNMPv2c, or          SNMPv3."     INDEX     {    sctpAssocId,   -- shared index                    sctpAssocLocalAddrType,                    sctpAssocLocalAddr }     ::= { sctpAssocLocalAddrTable 1 }   SctpAssocLocalAddrEntry ::= SEQUENCE {     sctpAssocLocalAddrType        InetAddressType,     sctpAssocLocalAddr            InetAddress,     sctpAssocLocalAddrStartTime   TimeStamp     }   sctpAssocLocalAddrType OBJECT-TYPE     SYNTAX         InetAddressType     MAX-ACCESS     not-accessible     STATUS         current     DESCRIPTION          "Internet type of local IP address used for this association."     ::= { sctpAssocLocalAddrEntry 1 }   sctpAssocLocalAddr OBJECT-TYPE     SYNTAX         InetAddress     MAX-ACCESS     not-accessible     STATUS         current     DESCRIPTION          "The value of a local IP address available for this          association. The type of this address is determined by the          value of sctpAssocLocalAddrType."     ::= { sctpAssocLocalAddrEntry 2 }Pastor & Belinchon          Standards Track                    [Page 27]

RFC 3873                  SCTP MIB using SMIv2            September 2004   sctpAssocLocalAddrStartTime OBJECT-TYPE     SYNTAX         TimeStamp     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The value of sysUpTime at the time that this row was          created."     ::= { sctpAssocLocalAddrEntry 3 }   -- Remote Addresses TABLE   -- **********************   sctpAssocRemAddrTable OBJECT-TYPE     SYNTAX         SEQUENCE OF SctpAssocRemAddrEntry     MAX-ACCESS     not-accessible     STATUS         current     DESCRIPTION          "Expanded table of sctpAssocTable based on the AssocId index.          This table shows data related to each remote peer IP address          which is used by this association."     ::= { sctpObjects  5 }   sctpAssocRemAddrEntry OBJECT-TYPE     SYNTAX         SctpAssocRemAddrEntry     MAX-ACCESS     not-accessible     STATUS         current     DESCRIPTION          "Information about the most important variables for every          remote IP address. There will be an entry for every remote IP          address defined for this association.          Implementors need to be aware that if the size of          sctpAssocRemAddr exceeds 114 octets then OIDs of column          instances in this table will have more than 128 sub-          identifiers and cannot be accessed using SNMPv1, SNMPv2c, or          SNMPv3."     INDEX   { sctpAssocId,   -- shared index               sctpAssocRemAddrType,               sctpAssocRemAddr }     ::= { sctpAssocRemAddrTable 1 }Pastor & Belinchon          Standards Track                    [Page 28]

RFC 3873                  SCTP MIB using SMIv2            September 2004   SctpAssocRemAddrEntry ::= SEQUENCE {     sctpAssocRemAddrType               InetAddressType,     sctpAssocRemAddr                   InetAddress,     sctpAssocRemAddrActive             TruthValue,     sctpAssocRemAddrHBActive           TruthValue,     sctpAssocRemAddrRTO                Unsigned32,     sctpAssocRemAddrMaxPathRtx         Unsigned32,     sctpAssocRemAddrRtx                Counter32,     -- Statistic     sctpAssocRemAddrStartTime          TimeStamp     }   sctpAssocRemAddrType OBJECT-TYPE     SYNTAX         InetAddressType     MAX-ACCESS     not-accessible     STATUS         current     DESCRIPTION          "Internet type of a remote IP address available for this          association."     ::= { sctpAssocRemAddrEntry 1 }   sctpAssocRemAddr OBJECT-TYPE     SYNTAX         InetAddress     MAX-ACCESS     not-accessible     STATUS         current     DESCRIPTION          "The value of a remote IP address available for this          association. The type of this address is determined by the          value of sctpAssocLocalAddrType."     ::= { sctpAssocRemAddrEntry 2 }   sctpAssocRemAddrActive OBJECT-TYPE     SYNTAX         TruthValue     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "This object gives information about the reachability of this          specific remote IP address.          When the object is set to 'true' (1), the remote IP address is          understood as Active. Active means that the threshold of no          answers received from this IP address has not been reached.Pastor & Belinchon          Standards Track                    [Page 29]

RFC 3873                  SCTP MIB using SMIv2            September 2004          When the object is set to 'false' (2), the remote IP address          is understood as Inactive. Inactive means that either no          heartbeat or any other message was received from this address,          reaching the threshold defined by the protocol."     REFERENCE          "The remote transport states are defined as Active and          Inactive in the SCTP,RFC2960."     ::= { sctpAssocRemAddrEntry 3 }   sctpAssocRemAddrHBActive OBJECT-TYPE     SYNTAX         TruthValue     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "This object indicates whether the optional Heartbeat check          associated to one destination transport address is activated          or not (value equal to true or false, respectively). "     ::= { sctpAssocRemAddrEntry 4 }   sctpAssocRemAddrRTO OBJECT-TYPE -- T3-rtx- Timer     SYNTAX         Unsigned32     UNITS          "milliseconds"     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The current Retransmission Timeout. T3-rtx timer as defined          in the protocol SCTP."     REFERENCE          "Section 6.3 in RFC2960 deals with the Retransmission Timer          Management."     ::= { sctpAssocRemAddrEntry 5 }   sctpAssocRemAddrMaxPathRtx OBJECT-TYPE     SYNTAX         Unsigned32     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "Maximum number of DATA chunks retransmissions allowed to a          remote IP address before it is considered inactive, as defined          inRFC2960."Pastor & Belinchon          Standards Track                    [Page 30]

RFC 3873                  SCTP MIB using SMIv2            September 2004     REFERENCE          "Section 8.2, 8.3 and 14 inRFC2960."     DEFVAL {5} -- number of attempts     ::= { sctpAssocRemAddrEntry 6 }   -- Remote Address Statistic   sctpAssocRemAddrRtx OBJECT-TYPE     SYNTAX         Counter32     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "Number of DATA chunks retransmissions to this specific IP          address. When T3-rtx expires, the DATA chunk that triggered          the T3 timer will be re-sent according to the retransmissions          rules. Every DATA chunk that is included in a SCTP packet and          was transmitted to this specific IP address before, will be          included in this counter.          Discontinuities in the value of this counter can occur at re-          initialization of the management system, and at other times as          indicated by the value of sctpAssocDiscontinuityTime."     ::= { sctpAssocRemAddrEntry 7 }   sctpAssocRemAddrStartTime OBJECT-TYPE     SYNTAX         TimeStamp     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The value of sysUpTime at the time that this row was          created."     ::= { sctpAssocRemAddrEntry 8 }   -- ASSOCIATION INVERSE TABLE   -- *************************   -- BY LOCAL PORT   sctpLookupLocalPortTable OBJECT-TYPE     SYNTAX         SEQUENCE OF SctpLookupLocalPortEntry     MAX-ACCESS     not-accessible     STATUS         current     DESCRIPTION          "With the use of this table, a list of associations which arePastor & Belinchon          Standards Track                    [Page 31]

RFC 3873                  SCTP MIB using SMIv2            September 2004          using the specified local port can be retrieved."     ::= { sctpObjects  6 }   sctpLookupLocalPortEntry OBJECT-TYPE     SYNTAX         SctpLookupLocalPortEntry     MAX-ACCESS     not-accessible     STATUS         current     DESCRIPTION          "This table is indexed by local port and association ID.          Specifying a local port, we would get a list of the          associations whose local port is the one specified."     INDEX         { sctpAssocLocalPort,                    sctpAssocId }     ::= { sctpLookupLocalPortTable 1 }   SctpLookupLocalPortEntry::= SEQUENCE {     sctpLookupLocalPortStartTime            TimeStamp     }   sctpLookupLocalPortStartTime OBJECT-TYPE     SYNTAX         TimeStamp     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The value of sysUpTime at the time that this row was created.          As the table will be created after the sctpAssocTable          creation, this value could be equal to the sctpAssocStartTime          object from the main table."     ::= { sctpLookupLocalPortEntry 1 }   -- BY REMOTE PORT   sctpLookupRemPortTable OBJECT-TYPE     SYNTAX         SEQUENCE OF SctpLookupRemPortEntry     MAX-ACCESS     not-accessible     STATUS         currentPastor & Belinchon          Standards Track                    [Page 32]

RFC 3873                  SCTP MIB using SMIv2            September 2004     DESCRIPTION          "With the use of this table, a list of associations which are          using the specified remote port can be got"     ::= { sctpObjects  7 }   sctpLookupRemPortEntry OBJECT-TYPE     SYNTAX         SctpLookupRemPortEntry     MAX-ACCESS     not-accessible     STATUS         current     DESCRIPTION          "This table is indexed by remote port and association ID.          Specifying a remote port we would get a list of the          associations whose local port is the one specified "     INDEX         { sctpAssocRemPort,                    sctpAssocId }     ::= { sctpLookupRemPortTable 1 }   SctpLookupRemPortEntry::= SEQUENCE {     sctpLookupRemPortStartTime              TimeStamp     }   sctpLookupRemPortStartTime OBJECT-TYPE     SYNTAX         TimeStamp     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The value of sysUpTime at the time that this row was created.          As the table will be created after the sctpAssocTable          creation, this value could be equal to the sctpAssocStartTime          object from the main table."     ::= { sctpLookupRemPortEntry 1 }   -- BY REMOTE HOST NAME   sctpLookupRemHostNameTable OBJECT-TYPE     SYNTAX         SEQUENCE OF SctpLookupRemHostNameEntry     MAX-ACCESS     not-accessible     STATUS         current     DESCRIPTION          "With the use of this table, a list of associations with that          particular host can be retrieved."Pastor & Belinchon          Standards Track                    [Page 33]

RFC 3873                  SCTP MIB using SMIv2            September 2004     ::= { sctpObjects  8 }   sctpLookupRemHostNameEntry OBJECT-TYPE     SYNTAX         SctpLookupRemHostNameEntry     MAX-ACCESS     not-accessible     STATUS         current     DESCRIPTION          "This table is indexed by remote host name and association ID.          Specifying a host name we would get a list of the associations          specifying that host name as the remote one.          Implementors need to be aware that if the size of          sctpAssocRemHostName exceeds 115 octets then OIDs of column          instances in this table will have more than 128 sub-          identifiers and cannot be accessed using SNMPv1, SNMPv2c, or          SNMPv3."     INDEX         { sctpAssocRemHostName,                    sctpAssocId }     ::= { sctpLookupRemHostNameTable 1 }   SctpLookupRemHostNameEntry::= SEQUENCE {     sctpLookupRemHostNameStartTime               TimeStamp     }   sctpLookupRemHostNameStartTime OBJECT-TYPE     SYNTAX         TimeStamp     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The value of sysUpTime at the time that this row was created.          As the table will be created after the sctpAssocTable          creation, this value could be equal to the sctpAssocStartTime          object from the main table."     ::= { sctpLookupRemHostNameEntry 1 }Pastor & Belinchon          Standards Track                    [Page 34]

RFC 3873                  SCTP MIB using SMIv2            September 2004   -- BY REMOTE PRIMARY IP ADDRESS   sctpLookupRemPrimIPAddrTable OBJECT-TYPE     SYNTAX         SEQUENCE OF SctpLookupRemPrimIPAddrEntry     MAX-ACCESS     not-accessible     STATUS         current     DESCRIPTION          "With the use of this table, a list of associations that have          the specified IP address as primary within the remote set of          active addresses can be retrieved."     ::= { sctpObjects  9 }   sctpLookupRemPrimIPAddrEntry OBJECT-TYPE     SYNTAX         SctpLookupRemPrimIPAddrEntry     MAX-ACCESS     not-accessible     STATUS         current     DESCRIPTION          "This table is indexed by primary address and association ID.          Specifying a primary address, we would get a list of the          associations that have the specified remote IP address marked          as primary.          Implementors need to be aware that if the size of          sctpAssocRemPrimAddr exceeds 114 octets then OIDs of column          instances in this table will have more than 128 sub-          identifiers and cannot be accessed using SNMPv1, SNMPv2c, or          SNMPv3."     INDEX         { sctpAssocRemPrimAddrType,                    sctpAssocRemPrimAddr,                    sctpAssocId }     ::= { sctpLookupRemPrimIPAddrTable 1 }   SctpLookupRemPrimIPAddrEntry::= SEQUENCE {     sctpLookupRemPrimIPAddrStartTime             TimeStamp     }   sctpLookupRemPrimIPAddrStartTime OBJECT-TYPE     SYNTAX         TimeStamp     MAX-ACCESS     read-only     STATUS         currentPastor & Belinchon          Standards Track                    [Page 35]

RFC 3873                  SCTP MIB using SMIv2            September 2004     DESCRIPTION          "The value of SysUpTime at the time that this row was created.          As the table will be created after the sctpAssocTable          creation, this value could be equal to the sctpAssocStartTime          object from the main table."     ::= { sctpLookupRemPrimIPAddrEntry 1 }   -- BY REMOTE IP ADDRESS   sctpLookupRemIPAddrTable OBJECT-TYPE     SYNTAX         SEQUENCE OF SctpLookupRemIPAddrEntry     MAX-ACCESS     not-accessible     STATUS         current     DESCRIPTION          "With the use of this table, a list of associations that have          the specified IP address as one of the remote ones can be          retrieved. "     ::= { sctpObjects  10 }   sctpLookupRemIPAddrEntry OBJECT-TYPE     SYNTAX         SctpLookupRemIPAddrEntry     MAX-ACCESS     not-accessible     STATUS         current     DESCRIPTION          "This table is indexed by a remote IP address and association          ID. Specifying an IP address we would get a list of the          associations that have the specified IP address included          within the set of remote IP addresses."     INDEX         { sctpAssocRemAddrType,                    sctpAssocRemAddr,                    sctpAssocId }     ::= { sctpLookupRemIPAddrTable 1 }   SctpLookupRemIPAddrEntry::= SEQUENCE {     sctpLookupRemIPAddrStartTime            TimeStamp     }Pastor & Belinchon          Standards Track                    [Page 36]

RFC 3873                  SCTP MIB using SMIv2            September 2004   sctpLookupRemIPAddrStartTime OBJECT-TYPE     SYNTAX         TimeStamp     MAX-ACCESS     read-only     STATUS         current     DESCRIPTION          "The value of SysUpTime at the time that this row was created.          As the table will be created after the sctpAssocTable          creation, this value could be equal to the sctpAssocStartTime          object from the main table."     ::= { sctpLookupRemIPAddrEntry 1 }   -- 4.1 Conformance Information   sctpMibConformance    OBJECT IDENTIFIER ::= { sctpMIB 2 }   sctpMibCompliances    OBJECT IDENTIFIER ::= { sctpMibConformance 1 }   sctpMibGroups         OBJECT IDENTIFIER ::= { sctpMibConformance 2 }   -- 4.1.1 Units of conformance   --   -- MODULE GROUPS   --   sctpLayerParamsGroup OBJECT-GROUP     OBJECTS   { sctpRtoAlgorithm,                 sctpRtoMin,                 sctpRtoMax,                 sctpRtoInitial,                 sctpMaxAssocs,                 sctpValCookieLife,                 sctpMaxInitRetr               }     STATUS    current     DESCRIPTION          "Common parameters for the SCTP layer, i.e., for all the          associations. They can usually be referred to as configuration          parameters."     ::= { sctpMibGroups 1 }Pastor & Belinchon          Standards Track                    [Page 37]

RFC 3873                  SCTP MIB using SMIv2            September 2004   sctpStatsGroup OBJECT-GROUP     OBJECTS   { sctpCurrEstab,                 sctpActiveEstabs,                 sctpPassiveEstabs,                 sctpAborteds,                 sctpShutdowns,                 sctpOutOfBlues,                 sctpChecksumErrors,                 sctpOutCtrlChunks,                 sctpOutOrderChunks,                 sctpOutUnorderChunks,                 sctpInCtrlChunks,                 sctpInOrderChunks,                 sctpInUnorderChunks,                 sctpFragUsrMsgs,                 sctpReasmUsrMsgs,                 sctpOutSCTPPacks,                 sctpInSCTPPacks,                 sctpDiscontinuityTime,                 sctpAssocT1expireds,                 sctpAssocT2expireds,                 sctpAssocRtxChunks,                 sctpAssocRemAddrRtx               }     STATUS    current     DESCRIPTION          "Statistics group. It includes the objects to collect state          changes in the SCTP protocol local layer and flow control          statistics."     ::= { sctpMibGroups 2 }   sctpPerAssocParamsGroup OBJECT-GROUP     OBJECTS   { sctpAssocRemHostName,                 sctpAssocLocalPort,                 sctpAssocRemPort,                 sctpAssocRemPrimAddrType,                 sctpAssocRemPrimAddr,                 sctpAssocHeartBeatInterval,                 sctpAssocState,                 sctpAssocInStreams,                 sctpAssocOutStreams,                 sctpAssocMaxRetr,                 sctpAssocPrimProcess,                 sctpAssocStartTime,                 sctpAssocDiscontinuityTime,Pastor & Belinchon          Standards Track                    [Page 38]

RFC 3873                  SCTP MIB using SMIv2            September 2004                 sctpAssocLocalAddrStartTime,                 sctpAssocRemAddrActive,                 sctpAssocRemAddrHBActive,                 sctpAssocRemAddrRTO,                 sctpAssocRemAddrMaxPathRtx,                 sctpAssocRemAddrStartTime               }     STATUS    current     DESCRIPTION          "The SCTP group of objects to manage per-association          parameters. These variables include all the SCTP basic          features."     ::= { sctpMibGroups 3 }   sctpPerAssocStatsGroup OBJECT-GROUP                 OBJECTS               { sctpAssocT1expireds,                 sctpAssocT2expireds,                 sctpAssocRtxChunks,                 sctpAssocRemAddrRtx               }     STATUS    current     DESCRIPTION          "Per Association Statistics group. It includes the objects to          collect flow control statistics per association."     ::= { sctpMibGroups 4 }   sctpInverseGroup OBJECT-GROUP     OBJECTS   { sctpLookupLocalPortStartTime,                sctpLookupRemPortStartTime,                sctpLookupRemHostNameStartTime,                sctpLookupRemPrimIPAddrStartTime,                sctpLookupRemIPAddrStartTime               }     STATUS    current     DESCRIPTION          "Objects used in the inverse lookup tables."     ::= { sctpMibGroups 5 }Pastor & Belinchon          Standards Track                    [Page 39]

RFC 3873                  SCTP MIB using SMIv2            September 2004   -- 4.1.2 Compliance Statements   --   -- MODULE COMPLIANCES   --   sctpMibCompliance MODULE-COMPLIANCE     STATUS  current     DESCRIPTION          "The compliance statement for SNMP entities which implement          this SCTP MIB Module.          There are a number of INDEX objects that cannot be represented          in the form of OBJECT clauses in SMIv2, but for which we have          the following compliance requirements, expressed in OBJECT          clause form in this description clause:   -- OBJECT        sctpAssocLocalAddrType   -- SYNTAX        InetAddressType {ipv4(1), ipv6(2)}   -- DESCRIPTION   --       It is only required to have IPv4 and IPv6 addresses without   --       zone indices.   --       The address with zone indices is required if an   --       implementation can connect multiple zones.   --   -- OBJECT        sctpAssocLocalAddr   -- SYNTAX        InetAddress (SIZE(4|16))   -- DESCRIPTION   --       An implementation is only required to support globally   --       unique IPv4 and IPv6 addresses.   --   -- OBJECT        sctpAssocRemAddrType   -- SYNTAX        InetAddressType {ipv4(1), ipv6(2)}   -- DESCRIPTION   --       It is only required to have IPv4 and IPv6 addresses without   --       zone indices.   --       The address with zone indices is required if an   --       implementation can connect multiple zones.   --   -- OBJECT        sctpAssocRemAddr   -- SYNTAX        InetAddress (SIZE(4|16))   -- DESCRIPTION   --       An implementation is only required to support globally   --       unique IPv4 and IPv6 addresses.   --          "  -- closes DESCRIPTION clause of MODULE-COMPLIANCE     MODULE  -- this modulePastor & Belinchon          Standards Track                    [Page 40]

RFC 3873                  SCTP MIB using SMIv2            September 2004          MANDATORY-GROUPS    {  sctpLayerParamsGroup,                                 sctpPerAssocParamsGroup,                                 sctpStatsGroup,                                 sctpPerAssocStatsGroup                              }          OBJECT  sctpAssocRemPrimAddrType          SYNTAX  InetAddressType { ipv4(1),                                    ipv6(2)                                  }          DESCRIPTION               "It is only required to have IPv4 and IPv6 addresses               without zone indices.               The address with zone indices is required if an               implementation can connect multiple zones."          OBJECT  sctpAssocRemPrimAddr          SYNTAX  InetAddress (SIZE(4|16))          DESCRIPTION               "An implementation is only required to support globally               unique IPv4 and globally unique IPv6 addresses."          OBJECT sctpAssocState          WRITE-SYNTAX  INTEGER { deleteTCB(9) }          MIN-ACCESS read-only          DESCRIPTION               "Only the deleteTCB(9) value MAY be set by a management               station at most. A read-only option is also considered to               be compliant with this MIB module description."          GROUP sctpInverseGroup          DESCRIPTION               "Objects used in inverse lookup tables. This should be               implemented, at the discretion of the implementers, for               easier lookups in the association tables"     ::= { sctpMibCompliances 1 }   ENDPastor & Belinchon          Standards Track                    [Page 41]

RFC 3873                  SCTP MIB using SMIv2            September 20045.  Compiling Notes   When compiling the MIB module warnings similar to the following may   occur:      -  warning: index of row `sctpAssocLocalAddrEntry' can exceed OID         size limit by 141 subidentifier(s)      -  warning: index of row `sctpAssocRemAddrEntry' can exceed OID         size limit by 141 subidentifier(s)      -  warning: index of row `sctpLookupRemHostNameEntry' can exceed         OID size limit by 140 subidentifier(s)      -  warning: index of row `sctpLookupRemPrimIPAddrEntry' can exceed         OID size limit by 141 subidentifier(s)      -  warning: index of row `sctpLookupRemIPAddrEntry' can exceed OID         size limit by 141 subidentifier(s)   These warnings are due to the fact that the row objects have index   objects of type InetAddress or OCTET STRING whose size limit is 255   octets, and if that size limit were reached the names of column   instances in those rows would exceed the 128 sub-identifier limit   imposed by current versions of the SNMP.  Actual limitations for the   index object sizes are noted in the conceptual row DESCRIPTION   clauses.  For the InetAddress index objects these size limits will   not be reached with any of the address types in current use.6.  References6.1.  Normative References   [RFC2578]    McCloghrie, K., Perkins, D., and J. Schoenwaelder,                "Structure of Management Information Version 2 (SMIv2)",                STD 58,RFC 2578, April 1999.   [RFC2579]    McCloghrie, K., Perkins, D., and J. Schoenwaelder,                "Textual Conventions for SMIv2", STD 58,RFC 2579, April                1999.   [RFC2580]    McCloghrie, K., Perkins, D., and J. Schoenwaelder,                "Conformance Statements for SMIv2", STD 58,RFC 2580,                April 1999.   [RFC2960]    Stewart, R., Xie, Q., Morneault, K., Sharp, C.,                Schwarzbauer, H., Taylor, T., Rytina, I., Kalla, M.,                Zhang, L., and V. Paxson, "Stream Control Transmission                Protocol",RFC 2960, October 2000.Pastor & Belinchon          Standards Track                    [Page 42]

RFC 3873                  SCTP MIB using SMIv2            September 2004   [RFC3291]    Daniele, M., Haberman, B., Routhier, S., and J.                Schoenwaelder, "Textual Conventions for Internet Network                Addresses",RFC 3291, May 2002.   [RFC3309]    Stone, J., Stewart, R., and D. Otis, "Stream Control                Transmission Protocol (SCTP) Checksum Change",RFC 3309,                September 2002.6.2.  Informative References   [RFC1213]    McCloghrie, K. and M. Rose, "Management Information Base                for Network Management of TCP/IP-based internets:MIB-                II", STD 17,RFC 1213, March 1991.   [RFC2012]    McCloghrie, K., "SNMPv2 Management Information Base for                the Transmission Control Protocol using SMIv2",RFC2012, November 1996.   [RFC3410]    Case, J., Mundy, R., Partain, D., and B. Stewart,                "Introduction and Applicability Statements for                Internet-Standard Management Framework",RFC 3410,                December 2002.   [VANJ]       Jacobson, V., "Congestion Avoidance and Control",                SIGCOMM 1988, Stanford, California.   [IPv6ARCH]   Deering, S., Haberman, B., Jinmei, T., Nordmark, E.,                Onoe, A., and B. Zill, "IPv6 Scoped Address                Architecture", Work in Progress, December 2002.   [sctpImplem] Stewart, R., Ong, L., Arias-Rodriguez, I., Caro, A., and                M. Tuexen, "Stream Control Transmission Protocol (SCTP)                Implementers Guide", Work in Progress, January 2002.   [TCPMIB]     Fenner, B., McCloghrie, K., Raghunarayan, R., and J.                Schoenwalder, "Management Information Base for the                Transmission Control Protocol (TCP)", Work in Progress,                November 2002.   [UDPMIB]     Fenner, B., "Management Information Base for User                Datagram Protocol (UDP)", Work in Progress, June 2002.   [MIBGUIDE]   Heard, C.M.,"Guidelines for MIB Authors and Reviewers",                Work in Progress, February 2003.Pastor & Belinchon          Standards Track                    [Page 43]

RFC 3873                  SCTP MIB using SMIv2            September 20047.  Security Considerations   There are management objects defined in this MIB that have a MAX-   ACCESS clause of read-write and/or read-create.  Such objects may be   considered sensitive or vulnerable in some network environments.  The   support for SET operations in a non-secure environment without proper   protection can have a negative effect on network operations.  These   are the tables and objects and their sensitivity/vulnerability:   o  The sctpAssocState object has a MAX-ACCESS clause of read-write,      which allows termination of an arbitrary connection.  Unauthorized      access could cause a denial of service.   Some of the readable objects in this MIB module (i.e., objects with a   MAX-ACCESS other than not-accessible) may be considered sensitive or   vulnerable in some network environments.  Thus, it is important to   control even GET and/or NOTIFY access to these objects and possibly   to even encrypt the values of these objects when sending them over   the network via SNMP.  These are the tables and objects and their   sensitivity/vulnerability:   o  The sctpAssocTable, sctpAssocLocalAddressTable,      sctpAssocRemAddressTable and the lookup tables contain objects      providing information on the active associations on the device,      local and peer's IP addresses, the status of these associations      and the associated processes.  This information may be used by an      attacker to launch attacks against known/unknown weakness in      certain protocols/applications.   o  The sctpAssocTable contains objects providing information on local      and remote ports objects, that can be used to identify what ports      are open on the machine and can thus suggest what attacks are      likely to succeed, without the attacker having to run a port      scanner.   SNMP versions prior to SNMPv3 did not include adequate security.   Even if the network itself is secure (for example by using IPSec),   even then, there is no control as to who on the secure network is   allowed to access and GET/SET (read/change/create/delete) the objects   in this MIB module.   It is RECOMMENDED that implementers consider the security features as   provided by the SNMPv3 framework (see[RFC3410], section 8),   including full support for the SNMPv3 cryptographic mechanisms (for   authentication and privacy).Pastor & Belinchon          Standards Track                    [Page 44]

RFC 3873                  SCTP MIB using SMIv2            September 2004   Further, deployment of SNMP versions prior to SNMPv3 is NOT   RECOMMENDED.  Instead, it is RECOMMENDED to deploy SNMPv3 and to   enable cryptographic security.  It is then a customer/operator   responsibility to ensure that the SNMP entity giving access to an   instance of this MIB module is properly configured to give access to   the objects only to those principals (users) that have legitimate   rights to indeed GET or SET (change/create/delete) them.   The above objects also have privacy implications, i.e., they disclose   who is connecting to what hosts.  These are sensitive from a   perspective of preventing traffic analysis, and also to protect   individual privacy.8.  Acknowledgments   The authors wish to thank Juergen Schoenwaelder, David Partain, Shawn   A. Routhier, Ed Yarwood, John Linton, Shyamal Prasad, Juan-Francisco   Martin, Dave Thaler, and Bert Wijnen for their invaluable comments.9.  Authors' Addresses   Javier Pastor-Balbas   Ericsson Espana S.A.   Network Signaling System Management   Via de los Poblados 13   Madrid, 28033   Spain   Phone: +34-91-339-1397   EMail: J.Javier.Pastor@ericsson.com   Maria-Carmen Belinchon   Ericsson Espana S.A.   Network Signaling System Management   Via de los Poblados 13   Madrid, 28033   Spain   Phone: +34-91-339-3535   EMail: maria.carmen.belinchon@ericsson.comPastor & Belinchon          Standards Track                    [Page 45]

RFC 3873                  SCTP MIB using SMIv2            September 200410.  Full Copyright Statement   Copyright (C) The Internet Society (2004).   This document is subject to the rights, licenses and restrictions   contained inBCP 78, and except as set forth therein, the authors   retain all their rights.   This document and the information contained herein are provided on an   "AS IS" basis and THE CONTRIBUTOR, THE ORGANIZATION HE/S HE   REPRESENTS OR IS SPONSORED BY (IF ANY), THE INTERNET SOCIETY AND THE   INTERNET ENGINEERING TASK FORCE DISCLAIM ALL WARRANTIES, EXPRESS OR   IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF   THE INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED   WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.Intellectual Property   The IETF takes no position regarding the validity or scope of any   Intellectual Property Rights or other rights that might be claimed to   pertain to the implementation or use of the technology described in   this document or the extent to which any license under such rights   might or might not be available; nor does it represent that it has   made any independent effort to identify any such rights.  Information   on the IETF's procedures with respect to rights in IETF Documents can   be found inBCP 78 andBCP 79.   Copies of IPR disclosures made to the IETF Secretariat and any   assurances of licenses to be made available, or the result of an   attempt made to obtain a general license or permission for the use of   such proprietary rights by implementers or users of this   specification can be obtained from the IETF on-line IPR repository athttp://www.ietf.org/ipr.   The IETF invites any interested party to bring to its attention any   copyrights, patents or patent applications, or other proprietary   rights that may cover technology that may be required to implement   this standard.  Please address the information to the IETF at ietf-   ipr@ietf.org.Acknowledgement   Funding for the RFC Editor function is currently provided by the   Internet Society.Pastor & Belinchon          Standards Track                    [Page 46]

[8]ページ先頭

©2009-2025 Movatter.jp