Movatterモバイル変換


[0]ホーム

URL:


[RFC Home] [TEXT|PDF|HTML] [Tracker] [IPR] [Info page]

Obsoleted by:2722 EXPERIMENTAL
Network Working Group                                        N. BrownleeRequest for Comments: 2063                    The University of AucklandCategory: Experimental                                          C. Mills                                            BBN Systems and Technologies                                                                 G. Ruth                                                  GTE Laboratories, Inc.                                                            January 1997Traffic Flow Measurement:  ArchitectureStatus of this Memo   This memo defines an Experimental Protocol for the Internet   community.  This memo does not specify an Internet standard of any   kind.  Discussion and suggestions for improvement are requested.   Distribution of this memo is unlimited.Abstract   This document describes an architecture for the measurement and   reporting of network traffic flows, discusses how this relates to an   overall network traffic flow architecture, and describes how it can   be used within the Internet.  It is intended to provide a starting   point for the Realtime Traffic Flow Measurement Working Group.Table of Contents 1 Statement of Purpose and Scope                                     2 2 Traffic Flow Measurement Architecture                              42.1 Meters and Traffic Flows . . . . . . . . . . . . . . . . . .42.2 Interaction Between METER and METER READER . . . . . . . . .62.3 Interaction Between MANAGER and METER  . . . . . . . . . . .62.4 Interaction Between MANAGER and METER READER . . . . . . . .72.5 Multiple METERs or METER READERs . . . . . . . . . . . . . .72.6 Interaction Between MANAGERs (MANAGER - MANAGER) . . . . . .82.7 METER READERs and APPLICATIONs . . . . . . . . . . . . . . .8 3 Traffic Flows and Reporting Granularity                            93.1 Flows and their Attributes . . . . . . . . . . . . . . . . .93.2 Granularity of Flow Measurements . . . . . . . . . . . . . .113.3 Rolling Counters, Timestamps, Report-in-One-Bucket-Only  . .13 4 Meters                                                            154.1 Meter Structure  . . . . . . . . . . . . . . . . . . . . . .154.2 Flow Table . . . . . . . . . . . . . . . . . . . . . . . . .174.3 Packet Handling, Packet Matching . . . . . . . . . . . . . .174.4 Rules and Rule Sets  . . . . . . . . . . . . . . . . . . . .214.5 Maintaining the Flow Table . . . . . . . . . . . . . . . . .244.6 Handling Increasing Traffic Levels . . . . . . . . . . . . .25Brownlee, et. al.             Experimental                      [Page 1]

RFC 2063         Traffic Flow Measurement: Architecture     January 1997 5 Meter Readers                                                     265.1 Identifying Flows in Flow Records  . . . . . . . . . . . . .265.2 Usage Records, Flow Data Files . . . . . . . . . . . . . . .275.3 Meter to Meter Reader:  Usage Record Transmission. . . . . .27 6 Managers                                                          286.1 Between Manager and Meter:  Control Functions  . . . . . . .286.2 Between Manager and Meter Reader:  Control Functions   . . .296.3 Exception Conditions . . . . . . . . . . . . . . . . . . . .316.4 Standard Rule Sets   . . . . . . . . . . . . . . . . . . . .32 7 APPENDICES                                                        337.1Appendix A: Network Characterisation . . . . . . . . . . . .33   7.2Appendix B: Recommended Traffic Flow Measurement Capabilities 347.3Appendix C: List of Defined Flow Attributes  . . . . . . . .357.4Appendix D: List of Meter Control Variables  . . . . . . . .36 8 Acknowledgments                                                   36 9 References                                                        3710 Security Considerations                                         3711 Authors' Addresses                                              371 Statement of Purpose and Scope   This document describes an architecture for traffic flow measurement   and reporting for data networks which has the following   characteristics:     - The traffic flow model can be consistently applied to any       protocol/application at any network layer (e.g.  network,       transport, application layers).     - Traffic flow attributes are defined in such a way that they are       valid for multiple networking protocol stacks, and that traffic       flow measurement implementations are useful in MULTI-PROTOCOL       environments.     - Users may specify their traffic flow measurement requirements       in a simple manner, allowing them to collect the flow data they       need while ignoring other traffic.     - The data reduction effort to produce requested traffic flow       information is placed as near as possible to the network       measurement point.  This reduces the volume of data to be       obtained (and transmitted across the network for storage),       and minimises the amount of processing required in traffic       flow analysis applications.Brownlee, et. al.             Experimental                      [Page 2]

RFC 2063         Traffic Flow Measurement: Architecture     January 1997   The architecture specifies common metrics for measuring traffic   flows.  By using the same metrics, traffic flow data can be exchanged   and compared across multiple platforms.  Such data is useful for:     - Understanding the behaviour of existing networks,     - Planning for network development and expansion,     - Quantification of network performance,     - Verifying the quality of network service, and     - Attribution of network usage to users.   The traffic flow measurement architecture is deliberately structured   so that specific protocol implementations may extend coverage to   multi-protocol environments and to other protocol layers, such as   usage measurement for application-level services.  Use of the same   model for both network- and application-level measurement may   simplify the development of generic analysis applications which   process and/or correlate any or all levels of traffic and usage   information.  Within this docuemt the term 'usage data' is used as a   generic term for the data obtained using the traffic flow measurement   architecture.   This document is not a protocol specification.  It specifies and   structures the information that a traffic flow measurement system   needs to collect, describes requirements that such a system must   meet, and outlines tradeoffs which may be made by an implementor.   For performance reasons, it may be desirable to use traffic   information gathered through traffic flow measurement in lieu of   network statistics obtained in other ways.  Although the   quantification of network performance is not the primary purpose of   this architecture, the measured traffic flow data may be used as an   indication of network performance.   A cost recovery structure decides "who pays for what." The major   issue here is how to construct a tariff (who gets billed, how much,   for which things, based on what information, etc).  Tariff issues   include fairness, predictability (how well can subscribers forecast   their network charges), practicality (of gathering the data and   administering the tariff), incentives (e.g.  encouraging off-peak   use), and cost recovery goals (100% recovery, subsidisation, profit   making).  Issues such as these are not covered here.   Background information explaining why this approach was selected is   provided by 'Traffic Flow Measurement:  Background' RFC [1].Brownlee, et. al.             Experimental                      [Page 3]

RFC 2063         Traffic Flow Measurement: Architecture     January 19972 Traffic Flow Measurement Architecture   A traffic flow measurement system is used by network Operations   personnel for managing and developing a network.  It provides a tool   for measuring and understanding the network's traffic flows.  This   information is useful for many purposes, as mentioned insection 1   (above).   The following sections outline a model for traffic flow measurement,   which draws from working drafts of the OSI accounting model [2].   Future extensions are anticipated as the model is refined to address   additional protocol layers.2.1 Meters and Traffic Flows   At the heart of the traffic measurement model are network entities   called traffic METERS. Meters count certain attributes (such as   numbers of packets and bytes) and classify them as belonging to   ACCOUNTABLE ENTITIES using other attributes (such as source and   destination addresses).  An accountable entity is someone who (or   something which) is responsible for some activitiy on the network.   It may be a user, a host system, a network, a group of networks, etc,   depending on the granularity specified by the meter's configuration.   We assume that routers or traffic monitors throughout a network are   instrumented with meters to measure traffic.  Issues surrounding the   choice of meter placement are discussed in the 'Traffic Flow   Measurement:  Background' RFC [1].  An important aspect of meters is   that they provide a way of succinctly aggregating entity usage   information.   For the purpose of traffic flow measurement we define the concept of   a TRAFFIC FLOW, which is an artificial logical equivalent to a call   or connection.  A flow is a portion of traffic, delimited by a start   and stop time, that was generated by a particular accountable entity.   Attribute values (source/destination addresses, packet counts, byte   counts, etc.)  associated with a flow are aggregate quantities   reflecting events which take place in the DURATION between the start   and stop times.  The start time of a flow is fixed for a given flow;   the end time may increase with the age of the flow.   For connectionless network protocols such as IP there is by   definition no way to tell whether a packet with a particular   source/destination combination is part of a stream of packets or not   - each packet is completely independent.  A traffic meter has, as   part of its configuration, a set of 'rules' which specify the flows   of interest, in terms of the values of their attributes.  It derives   attribute values from each observed packet, and uses these to decideBrownlee, et. al.             Experimental                      [Page 4]

RFC 2063         Traffic Flow Measurement: Architecture     January 1997   which flow they belong to.  Classifying packets into 'flows' in this   way provides an economical and practical way to measure network   traffic and ascribe it to accountable entities.   Usage information which is not deriveable from traffic flows may also   be of interest.  For example, an application may wish to record   accesses to various different information resources or a host may   wish to record the username (subscriber id) for a particular network   session.  Provision is made in the traffic flow architecture to do   this.  In the future the measurement model will be extended to gather   such information from applications and hosts so as to provide values   for higher-layer flow attributes.   As well as FLOWS and METERS, the traffic flow measurement model   includes MANAGERS, METER READERS and ANALYSIS APPLICAIONS, which are   explained in following sections.  The relationships between them are   shown by the diagram below.  Numbers on the diagram refer to sections   in this document.                    MANAGER                   /       \              2.3 /         \ 2.4                 /           \                /             \                       ANALYSIS           METER   <----->   METER READER  <----->   APPLICATION                     2.2                     2.7  - MANAGER: A traffic measurement manager is an application which    configures 'meter' entities and controls 'meter reader' entities.    It uses the data requirements of analysis applications to determine    the appropriate configurations for each meter, and the proper    operation of each meter reader.  It may well be convenient to    combine the functions of meter reader and manager within a single    network entity.  - METER: Meters are placed at measurement points determined by    network Operations personnel.  Each meter selectively records    network activity as directed by its configuration settings.  It can    also aggregate, transform and further process the recorded activity    before the data is stored.  The processed and stored results are    called the 'usage data.'  - METER READER: A meter reader reliably transports usage data from    meters so that it is available to analysis applications.Brownlee, et. al.             Experimental                      [Page 5]

RFC 2063         Traffic Flow Measurement: Architecture     January 1997  - ANALYSIS APPLICATION: An analysis application processes the usage    data so as to provide information and reports which are useful for    network engineering and management purposes.  Examples include:      -  TRAFFIC FLOW MATRICES, showing the total flow rates for         many of the possible paths within an internet.      -  FLOW RATE FREQUENCY DISTRIBUTIONS, indicating how flow         rates vary with time.      -  USAGE DATA showing the total traffic volumes sent and         received by particular hosts.   The operation of the traffic measurement system as a whole is best   understood by considering the interactions between its components.   These are described in the following sections.2.2 Interaction Between METER and METER READER   The information which travels along this path is the usage data   itself.  A meter holds usage data in an array of flow data records   known as the FLOW TABLE. A meter reader may collect the data in any   suitable manner.  For example it might upload a copy of the whole   flow table using a file transfer protocol, or read the records in the   current flow set one at a time using a suitable data transfer   protocol.  Note that the meter reader need not read complete flow   data records, a subset of their attribute values may well be   sufficient.   A meter reader may collect usage data from one or more meters.  Data   may be collected from the meters at any time.  There is no   requirement for collections to be synchronized in any way.2.3 Interaction Between MANAGER and METER   A manager is responsible for configuring and controlling one or more   meters.  At the time of writing a meter can only be controlled by a   single manager; in the future this restriction may be relaxed.  Each   meter's configuration includes information such as:  - Flow specifications, e.g.  which traffic flows are to be measured,    how they are to be aggregated, and any data the meter is required    to compute for each flow being measured.  - Meter control parameters, e.g.  the maximum size of its flow table,    the 'inactivity' time for flows (if no packets belonging to a flow    are seen for this time the flow is considered to have ended, i.e.    to have become idle).Brownlee, et. al.             Experimental                      [Page 6]

RFC 2063         Traffic Flow Measurement: Architecture     January 1997  - Sampling rate.  Normally every packet will be observed.  It may    sometimes be necessary to use sampling techniques to observe only    some of the packets.  (Sampling algorithms are not prescribed by    the architecture; it should be noted that before using sampling one    should verify the statistical validity of the algorithm used).    Current experience with the measurement architecture shows that a    carefully-designed and implemented meter compresses the data such    that in normal LANs and WANs of today sampling is really not    needed.2.4 Interaction Between MANAGER and METER READER   A manager is responsible for configuring and controlling one or more   meter readers.  A meter reader may only be controlled by a single   manager.  A meter reader needs to know at least the following for   every meter is is collecting usage data from:  - The meter's unique identity, i.e.  its network name or address.  - How often usage data is to be collected from the meter.  - Which flow records are to be collected (e.g.  all active flows, the    whole flow table, flows seen since a given time, etc.).  - Which attribute values are to be collected for the required flow    records (e.g.  all attributes, or a small subset of them)   Since redundant reporting may be used in order to increase the   reliability of usage data, exchanges among multiple entities must be   considered as well.  These are discussed below.2.5 Multiple METERs or METER READERs                 -- METER READER A --                /         |          \               /          |           \       =====METER 1     METER 2=====METER 3    METER 4=====                           \           |          /                            \          |         /                             -- METER READER B --   Several uniquely identified meters may report to one or more meter   readers.  The diagram above gives an example of how multiple meters   and meter readers could be used.Brownlee, et. al.             Experimental                      [Page 7]

RFC 2063         Traffic Flow Measurement: Architecture     January 1997   In the diagram above meter 1 is read by meter reader A, and meter 4   is read by meter reader B. Meters 1 and 4 have no redundancy; if   either fails, usage data for their network segments will be lost.   Meters 2 and 3, however, measure traffic on the same network segment.   One of them may fail leaving the other collecting the segment's usage   data.  Meters 2 and 3 are read by meter reader A and by meter reader   B.  If one meter reader fails, the other will continue collecting   usage data.   The architecture does not require multiple meter readers to be   synchronized.  In the situation above meter readers A and B could   both collect usage data at the same intervals, but not neccesarily at   the same times.  Note that because collections are asynchronous it is   unlikely that usage records from two different meter readers will   agree exactly.   If precisely synchronized collections are required this can be   achieved by having one manager request each meter to begin collecting   a new set of flows, then allowing all meter readers to collect the   usage data from the old sets of flows.   If there is only one meter reader and it fails, the meters continue   to run.  When the meter reader is restarted it can collect all of the   accumulated flow data.  Should this happen, time resolution will be   lost (because of the missed collections) but overall traffic flow   information will not.  The only exception to this would occur if the   traffic volume was sufficient to 'roll over' counters for some flows   during the failure; this is addressed in the section on 'Rolling   Counters.'2.6 Interaction Between MANAGERs (MANAGER - MANAGER)   Synchronization between multiple management systems is the province   of network management protocols.  This traffic flow measurement   architecture specifies only the network management controls necessary   to perform the traffic flow measurement function and does not address   the more global issues of simultaneous or interleaved (possibly   conflicting) commands from multiple network management stations or   the process of transferring control from one network management   station to another.2.7 METER READERs and APPLICATIONs   Once a collection of usage data has been assembled by a meter reader   it can be processed by an analysis application.  Details of analysis   applications - such as the reports they produce and the data they   require - are outside the scope of this architecture.Brownlee, et. al.             Experimental                      [Page 8]

RFC 2063         Traffic Flow Measurement: Architecture     January 1997   It should be noted, however, that analysis applications will often   require considerable amounts of input data.  An important part of   running a traffic flow measurement system is the storage and regular   reduction of flow data so as to produce daily, weekly or monthly   summary files for further analysis.  Again, details of such data   handling are outside the scope of this architecture.3 Traffic Flows and Reporting Granularity   A flow was defined insection 2.1 above in abstract terms as follows:    "A TRAFFIC FLOW is an artifical logical equivalent to a call or    connection, belonging to an ACCOUNTABLE ENTITY."   In practical terms, a flow is a stream of packets passing across a   network between two end points (or being sent from a single end   point), which have been summarized by a traffic meter for analysis   purposes.3.1 Flows and their Attributes   Every traffic meter maintains a table of 'flow records' for flows   seen by the meter.  A flow record holds the values of the ATTRIBUTES   of interest for its flow.  These attributes might include:  - ADDRESSES for the flow's source and destination.  These comprise    the protocol type, the source and destination addresses at various    network layers (extracted from the packet), and the number of the    interface on which the packet was observed.  - First and last TIMES when packets were seen for this flow, i.e.    the 'creation' and 'last activity' times for the flow.  - COUNTS for 'forward' (source to destination) and 'backward'    (destination to source) components (e.g.  packets and bytes) of the    flow's traffic.  The specifying of 'source' and 'destination' for    flows is discussed in the section on packet matching below.  - OTHER attributes, e.g.  information computed by the meter.   A flow's ACCOUNTABLE ENTITY is specified by the values of its ADDRESS   attributes.  For example, if a flow's address attributes specified   only that "source address = IP address 10.1.0.1," then all IP packets   from and to that address would be counted in that flow.  If a flow's   address list were specified as "source address = IP address 10.1.0.1,   destination address = IP address 26.1.0.1" then only IP packets   between 10.1.0.1 and 26.1.0.1 would be counted in that flow.Brownlee, et. al.             Experimental                      [Page 9]

RFC 2063         Traffic Flow Measurement: Architecture     January 1997   The addresses specifying a flow's address attributes may include one   or more of the following types:  - The INTERFACE NUMBER for the flow, i.e.  the interface on which the    meter measured the traffic.  Together with a unique address for the    meter this uniquely identifies a particular physical-level port.  - The ADJACENT ADDRESS, i.e.  the [n-1] layer address of the    immediate source or destination on the path of the packet.  For    example, if flow measurement is being performed at the IP layer on    an Ethernet LAN [3], an adjacent address is a six-octet Media    Access Control (MAC) address.  For a host connected to the same LAN    segment as the meter the adjacent address will be the MAC address    of that host.  For hosts on other LAN segments it will be the MAC    address of the adjacent (upstream or downstream) router carrying    the traffic flow.  - The PEER ADDRESS, which identifies the source or destination of the    PEER-LEVEL packet.  The form of a peer address will depend on the    network-layer protocol in use, and the network layer [n] at which    traffic measurement is being performed.  - The TRANSPORT ADDRESS, which identifies the source or destination    port for the packet, i.e.  its [n+1] layer address.  For example,    if flow measurement is being performed at the IP layer a transport    address is a two-octet UDP or TCP port number.   The four definitions above specify addresses for each of the four   lowest layers of the OSI reference model, i.e.  Physical layer, Link   layer, Network layer and Transport layer.  A FLOW RECORD stores both   the VALUE for each of its addresses (as described above) and a MASK   specifying which bits of the address value are being used and which   are ignored.  Note that if address bits are being ignored the meter   will set them to zero, however their actual values are undefined.   One of the key features of the traffic measurement architecture is   that attributes have essentially the same meaning for different   protocols, so that analysis applications can use the same reporting   formats for all protocols.  This is straightforward for peer   addresses; although the form of addresses differs for the various   protocols, the meaning of a 'peer address' remains the same.  It   becomes harder to maintain this correspondence at higher layers - for   example, at the Network layer IP, Novell IPX and AppleTalk all use   port numbers as a 'transport address,' but CLNP and DECnet have no   notion of ports.  Further work is needed here, particularly in   selecting attributes which will be suitable for the higher layers of   the OSI reference model.Brownlee, et. al.             Experimental                     [Page 10]

RFC 2063         Traffic Flow Measurement: Architecture     January 1997   Reporting by adjacent intermediate sources and destinations or simply   by meter interface (most useful when the meter is embedded in a   router) supports hierarchical Internet reporting schemes as described   in the 'Traffic Flow Measurement:  Background' RFC [1].  That is, it   allows backbone and regional networks to measure usage to just the   next lower level of granularity (i.e.  to the regional and   stub/enterprise levels, respectively), with the final breakdown   according to end user (e.g.  to source IP address) performed by the   stub/enterprise networks.   In cases where network addresses are dynamically allocated (e.g.   mobile subscribers), further subscriber identification will be   necessary if flows are to ascribed to individual users.  Provision is   made to further specify the accountable entity through the use of an   optional SUBSCRIBER ID as part of the flow id.  A subscriber ID may   be associated with a particular flow either through the current rule   set or by proprietary means within a meter, for example via protocol   exchanges with one or more (multi-user) hosts.  At this time a   subscriber ID is an arbitrary text string; later versions of the   architecture may specify its contents on more detail.3.2 Granularity of Flow Measurements   GRANULARITY is the 'control knob' by which an application and/or the   meter can trade off the overhead associated with performing usage   reporting against the level of detail supplied.  A coarser   granularity means a greater level of aggregation; finer granularity   means a greater level of detail.  Thus, the number of flows measured   (and stored) at a meter can be regulated by changing the granularity   of the accountable entity, the attributes, or the time intervals.   Flows are like an adjustable pipe - many fine-granularity streams can   carry the data with each stream measured individually, or data can be   bundled in one coarse-granularity pipe.   Flow granularity is controlled by adjusting the level of detail at   which the following are reported:  - The accountable entity (address attributes, discussed above).  - The categorisation of packets (other attributes, discussed below).  - The lifetime/duration of flows (the reporting interval needs to be    short enough to measure them with sufficient precision).Brownlee, et. al.             Experimental                     [Page 11]

RFC 2063         Traffic Flow Measurement: Architecture     January 1997   The set of rules controlling the determination of each packet's   accountable entity is known as the meter's CURRENT RULE SET. As will   be shown, the meter's current rule set forms an integral part of the   reported information, i.e.  the recorded usage information cannot be   properly interpreted without a definition of the rules used to   collect that information.   Settings for these granularity factors may vary from meter to meter.   They are determined by the meter's current rule set, so they will   change if network Operations personnel reconfigure the meter to use a   new rule set.  It is expected that the collection rules will change   rather infrequently; nonetheless, the rule set in effect at any time   must be identifiable via a RULE SET ID. Granularity of accountable   entities is further specified by additional ATTRIBUTES. These   attributes include:     - Meter variables such as the index of the flow's record in the flow       table and the rule set id for the rules which the meter was running       while the flow was observed.  The values of these attributes       provide a way of distinguishing flows observed by a meter at       different times.     - Attributes which record information derived from other attribute       values.  Six of these are defined (SourceClass, DestClass,       FlowClass, SourceKind, DestKind, FlowKind), and their meaning is       determined by the meter's rule set.  For example, one could have a       subroutine in the rule set which determined whether a source or       destination peer address was a member of an arbitrary list of       networks, and set SourceClass/DestClass to one if the source/dest       peer address was in the list or to zero otherwise.     - Administratively specified attributes such as Quality Of Service       and Priority, etc.  These are not defined at this time.     - Higher-layer (especially application-level) attributes.  These are       not defined at this time.   Settings for these granularity factors may vary from meter to meter.   They are determined by the meter's current rule set, so they will   change if network Operations personnel reconfigure the meter to use a   new rule set.   The LIFETIME of a flow is the time interval which began when the   meter observed the first packet belonging to the flow and ended when   it saw the last packet.  Flow lifetimes are very variable, but many -   if not most - are rather short.  A meter cannot measure lifetimes   directly; instead a meter reader collects usage data for flows which   have been active since the last collection, and an analysisBrownlee, et. al.             Experimental                     [Page 12]

RFC 2063         Traffic Flow Measurement: Architecture     January 1997   application may compare the data from each collection so as to   determine when each flow actually stopped.   The meter does, however, need to reclaim memory (i.e.  records in the   flow table) being held by idle flows.  The meter configuration   includes a variable called InactivityTimeout, which specifies the   minimum time a meter must wait before recovering the flow's record.   In addition, before recovering a flow record the meter must be sure   that the flow's data has been collected by at least one meter reader.   These 'lifetime' issues are considered further in the section on   meter readers (below).  A complete list of the attributes currently   defined is given inAppendix C later in this document.3.3 Rolling Counters, Timestamps, Report-in-One-Bucket-Only   Once an usage record is sent, the decision needs to be made whether   to clear any existing flow records or to maintain them and add to   their counts when recording subsequent traffic on the same flow.  The   second method, called rolling counters, is recommended and has   several advantages.  Its primary advantage is that it provides   greater reliability - the system can now often survive the loss of   some usage records, such as might occur if a meter reader failed and   later restarted.  The next usage record will very often contain yet   another reading of many of the same flow buckets which were in the   lost usage record.  The 'continuity' of data provided by rolling   counters can also supply information used for "sanity" checks on the   data itself, to guard against errors in calculations.   The use of rolling counters does introduce a new problem:  how to   distinguish a follow-on flow record from a new flow record.  Consider   the following example.                         CONTINUING FLOW        OLD FLOW, then NEW FLOW                         start time = 1            start time = 1   Usage record N:       flow count = 2000      flow count = 2000 (done)                         start time = 1            start time = 5   Usage record N+1:     flow count = 3000      new flow count = 1000   Total count:                 3000                    3000   In the continuing flow case, the same flow was reported when its   count was 2000, and again at 3000:  the total count to date is 3000.   In the OLD/NEW case, the old flow had a count of 2000.  Its recordBrownlee, et. al.             Experimental                     [Page 13]

RFC 2063         Traffic Flow Measurement: Architecture     January 1997   was then stopped (perhaps because of temporary idleness, or MAX   LIFETIME policy), but then more traffic with the same characteristics   arrived so a new flow record was started and it quickly reached a   count of 1000.  The total flow count from both the old and new   records is 3000.   The flow START TIMESTAMP attribute is sufficient to resolve this.  In   the example above, the CONTINUING FLOW flow record in the second   usage record has an old FLOW START timestamp, while the NEW FLOW   contains a recent FLOW START timestamp.   Each packet is counted in one and only one flow, so as to avoid   multiple counting of a single packet.  The record of a single flow is   informally called a "bucket." If multiple, sometimes overlapping,   records of usage information are required (aggregate, individual,   etc), the network manager should collect the counts in sufficiently   detailed granularity so that aggregate and combination counts can be   reconstructed in post-processing of the raw usage data.   For example, consider a meter from which it is required to record   both 'total packets coming in interface #1' and 'total packets   arriving from any interface sourced by IP address = a.b.c.d.'   Although a bucket can be declared for each case, it is not clear how   to handle a packet which satisfies both criteria.  It must only be   counted once.  By default it will be counted in the first bucket for   which it qualifies, and not in the other bucket.  Further, it is not   possible to reconstruct this information by post-processing.  The   solution in this case is to define not two, but THREE buckets, each   one collecting a unique combination of the two criteria:        Bucket 1:  Packets which came in interface 1,                   AND were sourced by IP address a.b.c.d        Bucket 2:  Packets which came in interface 1,                   AND were NOT sourced by IP address a.b.c.d        Bucket 3:  Packets which did NOT come in interface 1,                   AND were sourced by IP address a.b.c.d       (Bucket 4:  Packets which did NOT come in interface 1,                   AND NOT sourced by IP address a.b.c.d)   The desired information can now be reconstructed by post-processing.   "Total packets coming in interface 1" can be found by adding buckets   1 & 2, and "Total packets sourced by IP address a.b.c.d" can be found   by adding buckets 1 & 3.  Note that in this case bucket 4 is not   explicitly required since its information is not of interest, but it   is supplied here in parentheses for completeness.Brownlee, et. al.             Experimental                     [Page 14]

RFC 2063         Traffic Flow Measurement: Architecture     January 19974 Meters   A traffic flow meter is a device for collecting data about traffic   flows at a given point within a network; we will call this the   METERING POINT.  The header of every packet passing the network   metering point is offered to the traffic meter program.   A meter could be implemented in various ways, including:  - A dedicated small host, connected to a LAN (so that it can see all    packets as they pass by) and running a 'traffic meter' program.    The metering point is the LAN segment to which the meter is    attached.  - A multiprocessing system with one or more network interfaces, with    drivers enabling a traffic meter program to see packets.  In this    case the system provides multiple metering points - traffic flows    on any subset of its network interfaces can be measured.  - A packet-forwarding device such as a router or switch.  This is    similar to (b) except that every received packet should also be    forwarded, usually on a different interface.   The discussion in the following sections assumes that a meter may   only run a single rule set.  It is, however, possible for a meter to   run several rule sets concurrently, matching each packet against   every active rule set and producing a single flow table with flows   from all the active rule sets.  The overall effect of doing this   would be similar to running several independent meters, one for each   rule set.4.1 Meter Structure   An outline of the meter's structure is given in the following   diagram.   Briefly, the meter works as follows:  - Incoming packet headers arrive at the top left of the diagram and    are passed to the PACKET PROCESSOR.  - The packet processor passes them to the Packet Matching Engine    (PME) where they are classified.  - The PME is a Virtual Machine running a pattern matching program    contained in the CURRENT RULE SET. It is invoked by the Packet    Processor, and returns instructions on what to do with the packet.Brownlee, et. al.             Experimental                     [Page 15]

RFC 2063         Traffic Flow Measurement: Architecture     January 1997  - Some packets are classified as 'to be ignored.'  They are discarded    by the Packet Processor.  - Other packets are matched by the PME, which returns a FLOW KEY    describing the flow to which the packet belongs.  - The flow key is used to locate the flow's entry in the FLOW TABLE;    a new entry is created when a flow is first seen.  The entry's    packet and byte counters are updated.  - A meter reader may collect data from the flow table at any time.    It may use the 'collect' index to locate the flows to be collected    within the flow table.                  packet                +------------------+                  header                | Current Rule Set |                    |                   +--------+---------+                    |                            |           +--------*---------+       +----------*-------------+           | Packet Processor |<----->| Packet Matching Engine |           +--+------------+--+       +------------------------+              |            |       Ignore *            | Count via flow key                           |                        +--*--------------+                        | 'Search' index  |                        +--------+--------+                                 |                        +--------*--------+                        |                 |                        |   Flow Table    |                        |                 |                        +--------+--------+                                 |                        +--------*--------+                        | 'Collect' index |                        +--------+--------+                                 |                                 *                            Meter ReaderBrownlee, et. al.             Experimental                     [Page 16]

RFC 2063         Traffic Flow Measurement: Architecture     January 19974.2 Flow Table   Every traffic meter maintains a table of TRAFFIC FLOW RECORDS for   flows seen by the meter.  A flow record contains attribute values for   its flow, including:  - Addresses for the flow's source and destination.  These include    addresses and masks for various network layers (extracted from the    packet), and the number of the interface on which the packet was    observed.  - First and last times when packets were seen for this flow.  - Counts for 'forward' (source to destination) and 'backward'    (destination to source) components of the flow's traffic.  - Other attributes, e.g.  state of the flow record (discussed below).   The state of a flow record may be:  - INACTIVE: The flow record is not being used by the meter.  - CURRENT: The record is in use and describes a flow which belongs to    the 'current flow set,' i.e.  the set of flows recently seen by the    meter.  - IDLE: The record is in use and the flow which it describes is part    of the current flow set.  In addition, no packets belonging to this    flow have been seen for a period specified by the meter's    InactivityTime variable.4.3 Packet Handling, Packet Matching   Each packet header received by the traffic meter program is processed   as follows:  - Extract attribute values from the packet header and use them to    create a MATCH KEY for the packet.  - Match the packet's key against the current rule set, as explained    in detail below.   The rule set specifies whether the packet is to be counted or   ignored.  If it is to be counted the matching process produces a FLOW   KEY for the flow to which the packet belongs.  This flow key is used   to find the flow's record in the flow table; if a record does not yet   exist for this flow, a new flow record may be created.  The counts   for the matching flow record can then be incremented.Brownlee, et. al.             Experimental                     [Page 17]

RFC 2063         Traffic Flow Measurement: Architecture     January 1997   For example, the rule set could specify that packets to or from any   host in IP network 130.216 are to be counted.  It could also specify   that flow records are to be created for every pair of 24-bit (Class   C) subnets within network 130.216.   Each packet's match key is passed to the meter's PATTERN MATCHING   ENGINE (PME) for matching.  The PME is a Virtual Machine which uses a   set of instructions called RULES, i.e.  a RULE SET is a program for   the PME. A packet's match key contains an interface number, source   address (S) and destination address (D) values.  It does not,   however, contain any attribute masks for its attributes, only their   values.   If measured flows were unidirectional, i.e.  only counted packets   travelling in one direction, the matching process would be simple.   The PME would be called once to match the packet.  Any flow key   produced by a successful match would be used to find the flow's   record in the flow table, and that flow's counters would be updated.   Flows are, however, bidirectional, reflecting the forward and reverse   packets of a protocol interchange or 'session.'  Maintaining two sets   of counters in the meter's flow record makes the resulting flow data   much simpler to handle, since analysis programs do not have to gather   together the 'forward' and 'reverse' components of sessions.   Implementing bi-directional flows is, of course, more difficult for   the meter, since it must decide whether a packet is a 'forward'   packet or a 'reverse' one.  To make this decision the meter will   often need to invoke the PME twice, once for each possible packet   direction.   The diagram below describes the algorithm used by the traffic meter   to process each packet.  Flow through the diagram is from left to   right and top to bottom, i.e.  from the top left corner to the bottom   right corner.  S indicates the flow's source address (i.e.  its set   of source address attribute values) from the packet, and D indicates   its destination address.   There are several cases to consider.  These are:  - The packet is recognised as one which is TO BE IGNORED.  - The packet MATCHES IN BOTH DIRECTIONS. One situation in which this    could happen would be a rule set which matches flows within network    X (Source = X, Dest = X) but specifies that flows are to be created    for each subnet within network X, say subnets y and z.  If, for    example a packet is seen for y->z, the meter must check that flow    z->y is not already current before creating y->z.Brownlee, et. al.             Experimental                     [Page 18]

RFC 2063         Traffic Flow Measurement: Architecture     January 1997  - The packet MATCHES IN ONE DIRECTION ONLY. If its flow is already    current, its forward or reverse counters are incremented.    Otherwise it is added to the flow table and then counted.   The algorithm uses four functions, as follows:match(A->B) implements the PME.  It uses the meter's current rule set   to match the attribute values in the packet's match key.  A->B means   that the assumed source address is A and destination address B, i.e.   that the packet was travelling from A to B.  match() returns one of   three results:   'Ignore' means that the packet was matched but this flow is not            to be counted.   'Fail' means that the packet did not match.  It might, however            match with its direction reversed, i.e. from B to A.   'Suc'  means that the packet did match, i.e. it belongs to a flow            which is to be counted.current(A->B) succeeds if the flow A-to-B is current - i.e. has   a record in the flow table whose state is Current - and fails   otherwise.create(A->B) adds the flow A-to-B to the flow table, setting the   value for attributes - such as addresses - which remain constant,   and zeroing the flow's counters.count(A->B,f) increments the 'forward' counters for flow A-to-B.count(A->B,r) increments the 'reverse' counters for flow A-to-B.   'Forward' here means the counters for packets travelling from   A to B.  Note that count(A->B,f) is identical to count(B->A,r).Brownlee, et. al.             Experimental                     [Page 19]

RFC 2063         Traffic Flow Measurement: Architecture     January 1997                    Ignore    --- match(S->D) -------------------------------------------------+         | Suc   | Fail                                              |         |       |          Ignore                                   |         |      match(D->S) -----------------------------------------+         |       | Suc   | Fail                                      |         |       |       |                                           |         |       |       +-------------------------------------------+         |       |                                                   |         |       |             Suc                                   |         |      current(D->S) ---------- count(D->S,r) --------------+         |       | Fail                                              |         |       |                                                   |         |      create(D->S) ----------- count(D->S,r) --------------+         |                                                           |         |             Suc                                           |        current(S->D) ------------------ count(S->D,f) --------------+         | Fail                                                      |         |             Suc                                           |        current(D->S) ------------------ count(D->S,r) --------------+         | Fail                                                      |         |                                                           |        create(S->D) ------------------- count(S->D,f) --------------+                                                                     |                                                                     *   When writing rule sets one must remember that the meter will normally   try to match each packet in both directions.  It is particularly   important that the rule set does not contain inconsistencies which   will upset this process.   Consider, for example, a rule set which counts packets from source   network A to destination network B, but which ignores packets from   source network B. This is an obvious example of an inconsistent rule   set, since packets from network B should be counted as reverse   packets for the A-to-B flow.   This problem could be avoided by devising a language for specifying   rule files and writing a compiler for it, thus making it much easier   to produce correct rule sets.  Another approach would be to write a   'rule set consistency checker' program, which could detect problems   in hand-written rule sets.   In the short term the best way to avoid these problems is to write   rule sets which only clasify flows in the forward direction, and rely   on the meter to handle reverse-travelling packets.Brownlee, et. al.             Experimental                     [Page 20]

RFC 2063         Traffic Flow Measurement: Architecture     January 19974.4 Rules and Rule Sets   A rule set is an array of rules.  Rule sets are held within a meter   as entries in an array of rule sets.  One member of this array is the   CURRENT RULE SET, in that it is the one which is currently being used   by the meter to classify incoming packets.   Rule set 1 is built in to the meter and cannot be changed.  It is run   when the meter is started up, and provides a very coarse reporting   granularity; it is mainly useful for verifying that the meter is   running, before a 'useful' rule set is downloaded to it.   If the meter is instructed to use rule set 0, it will cease   measuring; all packets will be ignored until another (non-zero) rule   set is made current.   Each rule in a rule set is structured as follows:   +-------- test ---------+    +---- action -----+   attribute & mask = value:    opcode,  parameter;   Opcodes contain two flags:  'goto' and 'test.'  The PME maintains a   Boolean indicator called the 'test indicator,' which is initially set   (on).  Execution begins with rule 1, the first in the rule set.  It   proceeds as follows:   If the test indicator is on:      Perform the test, i.e. AND the attribute value with the         mask and compare it with the value.      If these are equal the test has succeeded; perform the         rule's action (below).      If the test fails execute the next rule in the rule set.      If there are no more rules in the rule set, return from the         match() function indicating failure.   If the test indicator is off, or the test (above) succeeded:      Set the test indicator to this rule's test flag value.      Determine the next rule to execute.         If the opcode has its goto flag set, its parameter value            specifies the number of the next rule.         Opcodes which don't have their goto flags set either            determine the next rule in special ways (Return),            or they terminate execution (Ignore, Fail, Count,            CountPkt).      Perform the action.Brownlee, et. al.             Experimental                     [Page 21]

RFC 2063         Traffic Flow Measurement: Architecture     January 1997   The PME maintains two 'history' data structures.  The first, the   'return' stack, simply records the index (i.e.  1-origin rule number)   of each Gosub rule as it is executed; Return rules pop their Gosub   rule index.  The second, the 'pattern' queue, is used to save   information for later use in building a flow key.  A flow key is   built by zeroing all its attribute values, then copying attribute and   mask information from the pattern stack in the order it was enqueued.   The opcodes are:         opcode         goto    test      1  Ignore           0       -      2  Fail             0       -      3  Count            0       -      4  CountPkt         0       -      5  Return           0       0      6  Gosub            1       1      7  GosubAct         1       0      8  Assign           1       1      9  AssignAct        1       0     10  Goto             1       1     11  GotoAct          1       0     12  PushRuleTo       1       1     13  PushRuleToAct    1       0     14  PushPktTo        1       1     15  PushPktToAct     1       0   The actions they perform are:   Ignore:         Stop matching, return from the match() function                   indicating that the packet is to be ignored.   Fail:           Stop matching, return from the match() function                   indicating failure.   Count:          Stop matching.  Save this rule's attribute name,                   mask and value in the PME's pattern queue, then                   construct a flow key for the flow to which this                   this packet belongs.  Return from the match()                   function indicating success.  The meter will use                   the flow key to locate the flow record for this                   packet's flow.   CountPkt:       As for Count, except that the masked value from                   the packet is saved in the PME's pattern queue                   instead of the rule's value.Brownlee, et. al.             Experimental                     [Page 22]

RFC 2063         Traffic Flow Measurement: Architecture     January 1997   Gosub:          Call a rule-matching subroutine.  Push the current                   rule number on the PME's return stack, set the                   test indicator then goto the specified rule.   GosubAct:       Same as Gosub, except that the test indicator is                   cleared before going to the specified rule.   Return:         Return from a rule-matching subroutine.  Pop the                   number of the calling gosub rule from the PME's                   'return' stack and add this rule's parameter value                   to it to determine the 'target' rule.  Clear the                   test indicator then goto the target rule.                   A subroutine call appears in a rule set as a Gosub                   rule followed by a small group of following rules.                   Since a Return action clears the test flag, the                   action of one of these 'following' rules will be                   executed; this allows the subroutine to return a                   result (in addition to any information it may save                   in the PME's pattern queue).   Assign:         Set the attribute specified in this rule to the                   value specified in this rule.  Set the test                   indicator then goto the specified rule.   AssignAct:      Same as Assign, except that the test indicator                   is cleared before going to the specified rule.   Goto:           Set the test indicator then goto the                   specified rule.   GotoAct:        Clear the test indicator then goto the specified                   rule.   PushRuleTo:     Save this rule's attribute name, mask and value                   in the PME's pattern queue. Set the test                   indicator then goto the specified rule.   PushRuleToAct:  Same as PushRuleTo, except that the test indicator                   is cleared before going to the specified rule.                   PushRuleTo actions may be used to save the value                   and mask used in a test, or (if the test is not                   performed) to save an arbitrary value and mask.Brownlee, et. al.             Experimental                     [Page 23]

RFC 2063         Traffic Flow Measurement: Architecture     January 1997   PushPktTo:      Save this rule's attribute name, mask, together                   with the masked value from the packet, in the                   PME's pattern queue.  SET the test indicator then                   goto the specified rule.   PushPktToAct:   Same as PushPktTo, except that the test indicator                   is cleared before going to the specified rule.                   PushPktTo actions may be used to save a value from                   the packet using a specified mask.  The test in                   PushPktTo rules will almost never be executed.   As well as the attributes applying directly to packets (such as   SourcePeerAddress, DestTransAddress, etc.)  the PME implements   several further attribtes.  These are:   Null:       Tests performed on the Null attribute always succeed.   v1 .. v5:   v1, v2, v3, v4 and v5 are 'meter variables.'  They               provide a way to pass parameters into rule-matching               subroutines.  Each may hold the name of a normal               attribute; its value is set by an Assign action.               When a meter variable appears as the attribute of a               rule, its value specifies the actual attribute to be               tested.  For example, if v1 had been assigned               SourcePeerAddress as its value, a rule with v1 as its               attribute would actually test SourcePeerAddress.   SourceClass, DestClass, FlowClass,   SourceKind, DestKind, FlowKind:               These six attributes may be set by executing PushRuleto               actions.  They allow the PME to save (in flow records)               information which has been built up during matching.               Since their values are only defined when matching is               complete (and the flow key is built) their values may               not be tested in rules.4.5 Maintaining the Flow Table   The flow table may be thought of as a 1-origin array of flow records.   (A particular implementation may, of course, use whatever data   structure is most suitable).  When the meter starts up there are no   known flows; all the flow records are in the 'inactive' state.   Each time a packet is seen for a flow which is not in the current   flow set a flow record is set up for it; the state of such a record   is 'current.'  When selecting a record for the new flow the meter   searches the flow table for a 'inactive' record - there is noBrownlee, et. al.             Experimental                     [Page 24]

RFC 2063         Traffic Flow Measurement: Architecture     January 1997   particular significance in the ordering of records within the table.   Flow data may be collected by a 'meter reader' at any time.  There is   no requirement for collections to be synchronized.  The reader may   collect the data in any suitable manner, for example it could upload   a copy of the whole flow table using a file transfer protocol, or it   could read the records in the current flow set row by row using a   suitable data transfer protocol.   The meter keeps information about collections, in particular it   maintains a LastCollectTime variable which remembers the time the   last collection was made.  A second variable, InactivityTime,   specifies the minimum time the meter will wait before considering   that a flow is idle.   The meter must recover records used for idle flows, if only to   prevent it running out of flow records.  Recovered flow records are   returned to the 'inactive' state.  A variety of recovery strategies   are possible, including the following:   One possible recovery strategy is to recover idle flow records as   soon as possible after their data has been collected.  To implement   this the meter could run a background process which scans the flow   table looking for 'current' flows whose 'last packet' time is earlier   than the meter's LastCollectTime.  This would be suitable for use   when one was interested in measuring flow lifetimes.   Another recovery strategy is to leave idle flows alone as long as   possible, which would be suitable if one was only interested in   measuring total traffic volumes.  It could be implemented by having   the meter search for collected idle flows only when it ran out of   'inactive' flow records.   One further factor a meter should consider before recovering a flow   is the number of meter readers which have collected the flow's data.   If there are multiple meter readers operating, network Operations   personnel should be able to specify the minimum number of meters - or   perhaps a specific list of meters - which should collect a flow's   data before its memory can be recovered.  This issue will be further   developed in the future.4.6 Handling Increasing Traffic Levels   Under normal conditions the meter reader specifies which set of usage   records it wants to collect, and the meter provides them.   If memory usage rises above the high-water mark the meter should   switch to a STANDBY RULE SET so as to increase the granularity ofBrownlee, et. al.             Experimental                     [Page 25]

RFC 2063         Traffic Flow Measurement: Architecture     January 1997   flow collection and decrease the rate at which new flows are created.   When the manager, usually as part of a regular poll, becomes aware   that the meter is using its standby rule set, it could decrease the   interval between collections.  The meter should also increase its   efforts to recover flow memory so as to reduce the number of idle   flows in memory.  When the situation returns to normal, the manager   may request the meter to switch back to its normal rule set.5 Meter Readers   Usage data is accumulated by a meter (e.g.  in a router) as memory   permits.  It is collected at regular reporting intervals by meter   readers, as specified by a manager.  The collected data is recorded   in a disk file called a FLOW DATA FILE, as a sequence of USAGE   RECORDS.   The following sections describe the contents of usage records and   flow data files.  Note, however, that at this stage the details of   such records and files is not specified in the architecture.   Specifying a common format for them would be a worthwhile future   development.5.1 Identifying Flows in Flow Records   Once a packet has been classified and is ready to be counted, an   appropriate flow data record must already exist in the flow table;   otherwise one must be created.  The flow record has a flexible format   where unnecessary identification attributes may be omitted.  The   determination of which attributes of the flow record to use, and of   what values to put in them, is specified by the current rule set.   Note that the combination of start time, rule set id and subscript   (row number in the flow table) provide a unique flow identifier,   regardless of the values of its other attributes.   The current rule set may specify additional information, e.g.  a   computed attribute value such as FlowKind, which is to be placed in   the attribute section of the usage record.  That is, if a particular   flow is matched by the rule set, then the corresponding flow record   should be marked not only with the qualifying identification   attributes, but also with the additional information.  Using this   feature, several flows may each carry the same FlowKind value, so   that the resulting usage records can be used in post-processing or   between meter reader and meter as a criterion for collection.Brownlee, et. al.             Experimental                     [Page 26]

RFC 2063         Traffic Flow Measurement: Architecture     January 19975.2 Usage Records, Flow Data Files   The collected usage data will be stored in flow data files on the   meter reader, one file for each meter.  As well as containing the   measured usage data, flow data files must contain information   uniquely identifiying the meter from which it was collected.   A USAGE RECORD contains the descriptions of and values for one or   more flows.  Quantities are counted in terms of number of packets and   number of bytes per flow.  Each usage record contains the entity   identifier of the meter (a network address), a time stamp and a list   of reported flows (FLOW DATA RECORDS). A meter reader will build up a   file of usage records by regularly collecting flow data from a meter,   using this data to build usage records and concatenating them to the   tail of a file.  Such a file is called a FLOW DATA FILE.   A usage record contains the following information in some form:   +-------------------------------------------------------------------+   |    RECORD IDENTIFIERS:                                            |   |      Meter Id (& digital signature if required)                   |   |      Timestamp                                                    |   |      Collection Rules ID                                          |   +-------------------------------------------------------------------+   |    FLOW IDENTIFIERS:            |    COUNTERS                     |   |      Address List               |       Packet Count              |   |      Subscriber ID (Optional)   |       Byte Count                |   |      Attributes (Optional)      |    Flow Start/Stop Time         |   +-------------------------------------------------------------------+5.3 Meter to Meter Reader:Usage Record Transmission   The usage record contents are the raison d'etre of the system.  The   accuracy, reliability, and security of transmission are the primary   concerns of the meter/meter reader exchange.  Since errors may occur   on networks, and Internet packets may be dropped, some mechanism for   ensuring that the usage information is transmitted intact is needed.   Flow data is moved from meter to meter reader via a series of   protocol exchanges between them.  This may be carried out in various   ways, moving individual attribute values, complete flows, or the   entire flow table (i.e.  all the active flows).  One possible method   of achieving this transfer is to use SNMP; the 'Traffic Flow   Measurement:  Meter MIB' document [4] gives details.  Note that this   is simply one example; the transfer of flow data from meter to meter   reader is not specified in this document.Brownlee, et. al.             Experimental                     [Page 27]

RFC 2063         Traffic Flow Measurement: Architecture     January 1997   The reliability of the data transfer method under light, normal, and   extreme network loads should be understood before selecting among   collection methods.   In normal operation the meter will be running a rule file which   provides the required degree of flow reporting granularity, and the   meter reader(s) will collect the flow data often enough to allow the   meter's garbage collection mechanism to maintain a stable level of   memory usage.   In the worst case traffic may increase to the point where the meter   is in danger of running completely out of flow memory.  The meter   implementor must decide how to handle this, for example by switching   to a default (extremely coarse granularity) rule set, by sending a   trap to the manager, or by attempting to dump flow data to the meter   reader.   Users of the Traffic Flow Measurement system should analyse their   requirements carefully and assess for themselves whether it is more   important to attempt to collect flow data at normal granularity   (increasing the collection frequency as needed to keep up with   traffic volumes), or to accept flow data with a coarser granularity.   Similarly, it may be acceptable to lose flow data for a short time in   return for being sure that the meter keeps running properly, i.e.  is   not overwhelmed by rising traffic levels.6 Managers   A manager configures meters and controls meter readers.  It does this   via the interactions described below.6.1 Between Manager and Meter:Control Functions  - DOWNLOAD RULE SET: A meter may hold an array of rule sets.  One of    these, the 'default' rule set, is built in to the meter and cannot    be changed; the others must be downloaded by the manager.  A    manager may use any suitable protocol exchange to achieve this, for    example an FTP file transfer or a series of SNMP SETs, one for each    row of the rule set.  - SWITCH TO SPECIFIED RULE SET: Once the rule sets have been    downloaded, the manager must instruct the meter which rule set it    is to actually run (i.e.  which is to be the current rule set), and    which is to be the standby rule set.  - SET HIGH WATER MARK: A percentage value interpreted by the meter    which tells the meter when to switch to its standby rule set, so as    to increase the granularity of the flows and conserve the meter'sBrownlee, et. al.             Experimental                     [Page 28]

RFC 2063         Traffic Flow Measurement: Architecture     January 1997    flow memory.  Once this has happened, the manager may also change    the polling frequency or the meter's control parameters (so as to    increase the rate at which the meter can recover memory from idle    flows).    If the high traffic levels persist, the meter's normal rule set may    have to be rewritten to permanently reduce the reporting    granularity.  - SET FLOW TERMINATION PARAMETERS: The meter should have the good    sense in situations where lack of resources may cause data loss to    purge flow records from its tables.  Such records may include:      -  Flows that have already been reported to at least one meter         reader, and show no activity since the last report,      -  Oldest flows, or      -  Flows with the smallest number of unreported packets.  - SET INACTIVITY TIMEOUT: This is a time in seconds since the last    packet was seen for a flow.  Flow records may be reclaimed if they    have been idle for at least this amount of time, and have been    collected in accordance with the current collection criteria.6.2 Between Manager and Meter Reader:Control Functions   Because there are a number of parameters that must be set for traffic   flow measurement to function properly, and viable settings may change   as a result of network traffic characteristics, it is desirable to   have dynamic network management as opposed to static meter   configurations.  Many of these operations have to do with space   tradeoffs - if memory at the meter is exhausted, either the reporting   interval must be decreased or a coarser granularity of aggregation   must be used so that more data fits into less space.   Increasing the reporting interval effectively stores data in the   meter; usage data in transit is limited by the effective bandwidth of   the virtual link between the meter and the meter reader, and since   these limited network resources are usually also used to carry user   data (the purpose of the network), the level of traffic flow   measurement traffic should be kept to an affordable fraction of the   bandwidth.  ("Affordable" is a policy decision made by the network   Operations personnel).  At any rate, it must be understood that the   operations below do not represent the setting of independent   variables; on the contrary, each of the values set has a direct and   measurable effect on the behaviour of the other variables.Brownlee, et. al.             Experimental                     [Page 29]

RFC 2063         Traffic Flow Measurement: Architecture     January 1997   Network management operations follow:  - MANAGER and METER READER IDENTIFICATION: The manager should ensure    that meters report to the correct set of collection stations, and    take steps to prevent unauthorised access to usage information.    The collection stations so identified should be prepared to poll if    necessary and accept data from the appropriate meters.  Alternate    collection stations may be identified in case both the primary    manager and the primary collection station are unavailable.    Similarly, alternate managers may be identified.  - REPORTING INTERVAL CONTROL: The usual reporting interval should be    selected to cope with normal traffic patterns.  However, it may be    possible for a meter to exhaust its memory during traffic spikes    even with a correctly set reporting interval.  Some mechanism must    be available for the meter to tell the manager that it is in danger    of exhausting its memory (by declaring a 'high water' condition),    and for the manager to arbitrate (by decreasing the polling    interval, letting nature take its course, or by telling the meter    to ask for help sooner next time).  - GRANULARITY CONTROL: Granularity control is a catch-all for all the    parameters that can be tuned and traded to optimise the system's    ability to reliably measure and store information on all the    traffic (or as close to all the traffic as an administration    requires).  Granularity      -  Controls flow-id granularities for each interface, and      -  Determines the number of buckets into which user traffic will         be lumped together.    Since granularity is controlled by the meter's current rule set,    the manager can only change it by requesting the meter to switch to    a different rule set.  The new rule set could be downloaded when    required, or it could have been downloaded as part of the meter's    initial configuration.  - FLOW LIFETIME CONTROL: Flow termination parameters include timeout    parameters for obsoleting inactive flows and removing them from    tables and maximum flow lifetimes.  This is intertwined with    reporting interval and granularity, and must be set in accordance    with the other parameters.Brownlee, et. al.             Experimental                     [Page 30]

RFC 2063         Traffic Flow Measurement: Architecture     January 19976.3 Exception Conditions   Exception conditions must be handled, particularly occasions when the   meter runs out of buffer space.  Since, to prevent counting any   packet twice, packets can only be counted in a single flow at any   given time, discarding records will result in the loss of   information.  The mechanisms to deal with this are as follows:  - METER OUTAGES: In case of impending meter outages (controlled    crashes, etc.)  the meter could send a trap to the manager.  The    manager could then request one or more meter readers to pick up the    usage record from the meter.    Following an uncontrolled meter outage such as a power failure, the    meter could send a trap to the manager indicating that it has    restarted.  The manager could then download the meter's correct    rule set and advise the meter reader(s) that the meter is running    again.  Alternatively, the meter reader may discover from its    regular poll that a meter has failed and restarted.  It could then    advise the manager of this, instead of relying on a trap from the    meter.  - METER READER OUTAGES: If the collection system is down or isolated,    the meter should try to inform the manager of its failure to    communicate with the collection system.  Usage data is maintained    in the flows' rolling counters, and can be recovered when the meter    reader is restarted.  - MANAGER OUTAGES: If the manager fails for any reason, the meter    should continue measuring and the meter reader(s) should keep    gathering usage records.  - BUFFER PROBLEMS: The network manager may realise that there is a    'low memory' condition in the meter.  This can usually be    attributed to the interaction between the following controls:      -  The reporting interval is too infrequent,      -  The reporting granularity is too fine, or      -  The throughput/bandwidth of circuits carrying the usage         data is too low.    The manager may change any of these parameters in response to the    meter (or meter reader's) plea for help.Brownlee, et. al.             Experimental                     [Page 31]

RFC 2063         Traffic Flow Measurement: Architecture     January 19976.4 Standard Rule Sets   Although the rule table is a flexible tool, it can also become very   complex.  It may be helpful to develop some rule sets for common   applications:  - PROTOCOL TYPE: The meter records packets by protocol type.  This    will be the default rule table for Traffic Flow Meters.  - ADJACENT SYSTEMS: The meter records packets by the MAC address of    the Adjacent Systems (neighbouring originator or next-hop).    (Variants on this table are "report source" or "report sink" only.)    This strategy might be used by a regional or backbone network which    wants to know how much aggregate traffic flows to or from its    subscriber networks.  - END SYSTEMS: The meter records packets by the IP address pair    contained in the packet.  (Variants on this table are "report    source" or "report sink" only.)  This strategy might be used by an    End System network to get detailed host traffic matrix usage data.  - TRANSPORT TYPE: The meter records packets by transport address; for    IP packets this provides usage information for the various IP    services.  - HYBRID SYSTEMS: Combinations of the above, e.g.  for one interface    report End Systems, for another interface report Adjacent Systems.    This strategy might be used by an enterprise network to learn    detail about local usage and use an aggregate count for the shared    regional network.Brownlee, et. al.             Experimental                     [Page 32]

RFC 2063         Traffic Flow Measurement: Architecture     January 19977 APPENDICES7.1Appendix A: Network Characterisation   Internet users have extraordinarily diverse requirements.  Networks   differ in size, speed, throughput, and processing power, among other   factors.  There is a range of traffic flow measurement capabilities   and requirements.  For traffic flow measurement purposes, the   Internet may be viewed as a continuum which changes in character as   traffic passes through the following representative levels:        International                    |        Backbones/National        ---------------                                 /              \        Regional/MidLevel     ----------   ----------                             /   \     \  /   /     \        Stub/Enterprise     ---   ---   ---   ----   ----                            |||   |||   |||   ||||   ||||        End-Systems/Hosts   xxx   xxx   xxx   xxxx   xxxx   Note that mesh architectures can also be built out of these   components, and that these are merely descriptive terms.  The nature   of a single network may encompass any or all of the descriptions   below, although some networks can be clearly identified as a single   type.   BACKBONE networks are typically bulk carriers that connect other   networks.  Individual hosts (with the exception of network management   devices and backbone service hosts) typically are not directly   connected to backbones.   REGIONAL networks are closely related to backbones, and differ only   in size, the number of networks connected via each port, and   geographical coverage.  Regionals may have directly connected hosts,   acting as hybrid backbone/stub networks.  A regional network is a   SUBSCRIBER to the backbone.   STUB/ENTERPRISE networks connect hosts and local area networks.   STUB/ENTERPRISE networks are SUBSCRIBERS to regional and backbone   networks.   END SYSTEMS, colloquially HOSTS, are SUBSCRIBERS to any of the above   networks.   Providing a uniform identification of the SUBSCRIBER in finer   granularity than that of end-system, (e.g.  user/account), is beyond   the scope of the current architecture, although an optional attributeBrownlee, et. al.             Experimental                     [Page 33]

RFC 2063         Traffic Flow Measurement: Architecture     January 1997   in the traffic flow measurement record may carry system-specific   "accountable (billable) party" labels so that meters can implement   proprietary or non-standard schemes for the attribution of network   traffic to responsible parties.7.2Appendix B: Recommended Traffic Flow Measurement Capabilities   Initial recommended traffic flow measurement conventions are outlined   here according to the following Internet building blocks.  It is   important to understand what complexity reporting introduces at each   network level.  Whereas the hierarchy is described top-down in the   previous section, reporting requirements are more easily addressed   bottom-up.        End-Systems        Stub Networks        Enterprise Networks        Regional Networks        Backbone Networks   END-SYSTEMS are currently responsible for allocating network usage to   end-users, if this capability is desired.  From the Internet Protocol   perspective, end-systems are the finest granularity that can be   identified without protocol modifications.  Even if a meter violated   protocol boundaries and tracked higher-level protocols, not all   packets could be correctly allocated by user, and the definition of   user itself varies too widely from operating system to operating   system (e.g.  how to trace network usage back to users from shared   processes).   STUB and ENTERPRISE networks will usually collect traffic data either   by end- system network address or network address pair if detailed   reporting is required in the local area network.  If no local   reporting is required, they may record usage information in the exit   router to track external traffic only.  (These are the only networks   which routinely use attributes to perform reporting at granularities   finer than end-system or intermediate-system network address.)   REGIONAL networks are intermediate networks.  In some cases,   subscribers will be enterprise networks, in which case the   intermediate system network address is sufficient to identify the   regional's immediate subscriber.  In other cases, individual hosts or   a disjoint group of hosts may constitute a subscriber.  Then end-   system network address pairs need to be tracked for those   subscribers.  When the source may be an aggregate entity (such as a   network, or adjacent router representing traffic from a world of   hosts beyond) and the destination is a singular entity (or vice   versa), the meter is said to be operating as a HYBRID system.Brownlee, et. al.             Experimental                     [Page 34]

RFC 2063         Traffic Flow Measurement: Architecture     January 1997   At the regional level, if the overhead is tolerable it may be   advantageous to report usage both by intermediate system network   address (e.g.  adjacent router address) and by end-system network   address or end-system network address pair.   BACKBONE networks are the highest level networks operating at higher   link speeds and traffic levels.  The high volume of traffic will in   most cases preclude detailed traffic flow measurement.  Backbone   networks will usually account for traffic by adjacent routers'   network addresses.7.3Appendix C: List of Defined Flow Attributes   This Appendix provides a checklist of the attributes defined to date;   others will be added later as the Traffic Measurement Architecture is   further developed.   0  Null   1  Flow Subscript                Integer    Flow table info   2  Flow Status                   Integer   4  Source Interface              Integer    Source Address   5  Source Adjacent Type          Integer   6  Source Adjacent Address       String   7  Source Adjacent Mask          String   8  Source Peer Type              Integer   9  Source Peer Address           String  10  Source Peer Mask              String  11  Source Trans Type             Integer  12  Source Trans Address          String  13  Source Trans Mask             String  14  Destination Interface         Integer    Destination Address  15  Destination Adjacent Type     Integer  16  Destination Adjacent Address  String  17  Destination AdjacentMask      String  18  Destination PeerType          Integer  19  Destination PeerAddress       String  20  Destination PeerMask          String  21  Destination TransType         Integer  22  Destination TransAddress      String  23  Destination TransMask         String  24  Packet Scale Factor           Integer    'Other' attributes  25  Byte Scale Factor             Integer  26  Rule Set Number               Integer  27  Forward Bytes                 Counter    Source-to-Dest counters  28  Forward Packets               CounterBrownlee, et. al.             Experimental                     [Page 35]

RFC 2063         Traffic Flow Measurement: Architecture     January 1997  29  Reverse Bytes                 Counter    Dest-to-Source counters  30  Reverse Packets               Counter  31  First Time                    TimeTicks  Activity times  32  Last Active Time              TimeTicks  33  Source Subscriber ID          String     Session attributes  34  Destination Subscriber ID     String  35  Session ID                    String  36  Source Class                  Integer    'Computed' attributes  37  Destination Class             Integer  38  Flow Class                    Integer  39  Source Kind                   Integer  40  Destination Kind              Integer  41  Flow Kind                     Integer  51  V1                            Integer    Meter variables  52  V2                            Integer  53  V3                            Integer  54  V4                            Integer  55  V5                            Integer7.4Appendix D: List of Meter Control Variables      Current Rule Set Number       Integer      Standby Rule Set Number       Integer      High Water Mark               Percentage      Flood Mark                    Percentage      Inactivity Timeout (seconds)  Integer      Last Collect Time             TimeTicks8 Acknowledgments   This document was initially produced under the auspices of the IETF's   Internet Accounting Working Group with assistance from SNMP, RMON and   SAAG working groups.  This version documents the implementation work   done by the Internet Accounting Working Group, and is intended to   provide a starting point for the Realtime Traffic Flow Measurement   Working Group.  Particular thanks are due to Stephen Stibler (IBM   Research) for his patient and careful comments during the preparation   of this memo.Brownlee, et. al.             Experimental                     [Page 36]

RFC 2063         Traffic Flow Measurement: Architecture     January 19979 References   [1] Mills, C., Hirsch, G. and G. Ruth, "Internet Accounting   Background",RFC 1272, Bolt Beranek and Newman Inc., Meridian   Technology Corporation, November 1991.   [2] International Standards Organisation (ISO), "Management   Framework," Part 4 of Information Processing Systems Open   Systems Interconnection Basic Reference Model, ISO 7498-4,   1994.   [3] IEEE 802.3/ISO 8802-3 Information Processing Systems -   Local Area Networks - Part 3:  Carrier sense multiple access   with collision detection (CSMA/CD) access method and physical   layer specifications, 2nd edition, September 21, 1990.   [4] Brownlee, N., "Traffic Flow Measurement:  Meter MIB",RFC 2064, The University of Auckland, January 1997.10 Security Considerations   Security issues are not discussed in detail in this document.  The   meter's management and collection protocols are responsible for   providing sufficient data integrity and confidentiality.11 Authors' Addresses   Nevil Brownlee   Information Technology Systems & Services   The University of Auckland   Phone: +64 9 373 7599 x8941   EMail: n.brownlee @auckland.ac.nz   Cyndi Mills   BBN Systems and Technologies   Phone: +1 617 873 4143   EMail: cmills@bbn.com   Greg Ruth   GTE Laboratories, Inc   Phone: +1 617 466 2448   EMail: gruth@gte.comBrownlee, et. al.             Experimental                     [Page 37]