Movatterモバイル変換


[0]ホーム

URL:


[RFC Home] [TEXT|PDF|HTML] [Tracker] [IPR] [Errata] [Info page]

HISTORIC
Errata Exist
Network Working Group                                         T. PummillRequest for Comments: 1878                                       AlantecObsoletes:1860                                               B. ManningCategory: Informational                                              ISI                                                           December 1995Variable Length Subnet Table For IPv4Status of this Memo   This memo provides information for the Internet community.  This memo   does not specify an Internet standard of any kind.  Distribution of   this memo is unlimited.Abstract   This memo clarifies issues surrounding subnetting IP networks by   providing a standard subnet table.  This table includes subnetting   for Class A, B, and C networks, as well as Network IDs, host ranges   and IP broadcast addresses with emphasis on Class C subnets.   This memo is intended as an informational companion to Subneting RFC   [1] and the Hosts Requirements RFC [2].Introduction   The growth of networking since the time of STD 5,RFC 950 and STD 3,RFC 1123 has resulted in larger and more complex network subnetting.   The previously mentioned RFCs comprise the available guidelines for   creating subnetted networks, however they have occassionaly been   misinterpreted leading to confusion regarding proper subnetting.   This document itemizes the potential values for IPv4 subnets.   Additional information is provided for Hex and Decmial values,   classfull equivalants, and number of addresses available within the   indicated block.Pummill & Manning            Informational                      [Page 1]

RFC 1878                      Subnet Table                 December 1995Table   The following table lists the variable length subnets from 1 to 32,   the CIDR [3] representation form (/xx) and the Decmial equivalents.   (M = Million, K=Thousand, A,B,C= traditional class values)   Mask value:                             # of   Hex            CIDR   Decimal           addresses  Classfull   80.00.00.00    /1     128.0.0.0         2048 M     128 A   C0.00.00.00    /2     192.0.0.0         1024 M      64 A   E0.00.00.00    /3     224.0.0.0          512 M      32 A   F0.00.00.00    /4     240.0.0.0          256 M      16 A   F8.00.00.00    /5     248.0.0.0          128 M       8 A   FC.00.00.00    /6     252.0.0.0           64 M       4 A   FE.00.00.00    /7     254.0.0.0           32 M       2 A   FF.00.00.00    /8     255.0.0.0           16 M       1 A   FF.80.00.00    /9     255.128.0.0          8 M     128 B   FF.C0.00.00   /10     255.192.0.0          4 M      64 B   FF.E0.00.00   /11     255.224.0.0          2 M      32 B   FF.F0.00.00   /12     255.240.0.0       1024 K      16 B   FF.F8.00.00   /13     255.248.0.0        512 K       8 B   FF.FC.00.00   /14     255.252.0.0        256 K       4 B   FF.FE.00.00   /15     255.254.0.0        128 K       2 B   FF.FF.00.00   /16     255.255.0.0         64 K       1 B   FF.FF.80.00   /17     255.255.128.0       32 K     128 C   FF.FF.C0.00   /18     255.255.192.0       16 K      64 C   FF.FF.E0.00   /19     255.255.224.0        8 K      32 C   FF.FF.F0.00   /20     255.255.240.0        4 K      16 C   FF.FF.F8.00   /21     255.255.248.0        2 K       8 C   FF.FF.FC.00   /22     255.255.252.0        1 K       4 C   FF.FF.FE.00   /23     255.255.254.0      512         2 C   FF.FF.FF.00   /24     255.255.255.0      256         1 C   FF.FF.FF.80   /25     255.255.255.128    128       1/2 C   FF.FF.FF.C0   /26     255.255.255.192     64       1/4 C   FF.FF.FF.E0   /27     255.255.255.224     32       1/8 C   FF.FF.FF.F0   /28     255.255.255.240     16      1/16 C   FF.FF.FF.F8   /29     255.255.255.248      8      1/32 C   FF.FF.FF.FC   /30     255.255.255.252      4      1/64 C   FF.FF.FF.FE   /31     255.255.255.254      2     1/128 C   FF.FF.FF.FF   /32     255.255.255.255   This is a single host routePummill & Manning            Informational                      [Page 2]

RFC 1878                      Subnet Table                 December 1995Subnets and Networks   The number of available network and host addresses are derived from   the number of bits used for subnet masking.  The tables below depict   the number of subnetting bits and the resulting network, broadcast   address, and host addresses.  Please note that all-zeros and all-ones   subnets are included in Tables 1-1 and 1-2 per the current,   standards- based practice for using all definable subnets [4].   Table 1-1 represents traditional subnetting of a Class B network   address.Subnet Mask     # of nets    Net. Addr.  Host Addr Range  Brodcast Addr.Bits of Subnet  hosts/subnet255.255.128.0   2 nets      N.N.0.0     N.N.0-127.N      N.N.127.2551 bit subnet  32766         N.N.128.0   N.N.128-254.N    N.N.254.255255.255.192.0   4 nets      N.N.0.0     N.N.0-63.N       N.N.63.2552 bit subnet  16382         N.N.64.0    N.N.64-127.N     N.N.127.255                              N.N.128.0   N.N.128-191.N    N.N.191.255                              N.N.192.0   N.N.192-254.N    N.N.254.255255.255.224.0   8 nets      N.N.0.0     N.N.0-31.N       N.N.31.2553 bit subnet  8190          N.N.32.0    N.N.32-63.N      N.N.63.255                              N.N.64.0    N.N.64-95.N      N.N.95.255                              N.N.96.0    N.N.96-127.N     N.N.127.255                              N.N.128.0   N.N.128-159.N    N.N.159.255                              N.N.160.0   N.N.160-191.N    N.N.191.255                              N.N.192.0   N.N.192-223.N    N.N.223.255                              N.N.224.0   N.N.224-254.N    N.N.254.255255.255.240.0   16 nets     N.N.0.0     N.N.0-15.N       N.N.15.2554 bit subnet  4094          N.N.16.0    N.N.16-31.N      N.N.31.255                              N.N.32.0    N.N.32-47.N      N.N.47.255                              N.N.48.0    N.N.48-63.N      N.N.63.255                              N.N.64.0    N.N.64-79.N      N.N.79.255                              N.N.80.0    N.N.80-95.N      N.N.95.255                              N.N.96.0    N.N.96-111.N     N.N.111.255                              N.N.112.0   N.N.112-127.N    N.N.127.255                              N.N.128.0   N.N.128-143.N    N.N.143.255                              N.N.144.0   N.N.144-159.N    N.N.159.255                              N.N.160.0   N.N.160-175.N    N.N.175.255                              N.N.176.0   N.N.176-191.N    N.N.191.255                              N.N.192.0   N.N.192-207.N    N.N.207.255                              N.N.208.0   N.N.208-223.N    N.N.223.255                              N.N.224.0   N.N.224-239.N    N.N.239.255                              N.N.240.0   N.N.240-254.N    N.N.254.255Pummill & Manning            Informational                      [Page 3]

RFC 1878                      Subnet Table                 December 1995255.255.248.0   32 nets     N.N.0.0     N.N.0-7.N        N.N.7.2555 bit subnet  2046          N.N.8.0     N.N.8-15.N       N.N.15.255                              N.N.16.0    N.N.16-23.N      N.N.23.255                              N.N.24.0    N.N.24-31.N      N.N.31.255                              N.N.32.0    N.N.32-39.N      N.N.39.255                              N.N.40.0    N.N.40-47.N      N.N.47.255                              N.N.48.0    N.N.48-55.N      N.N.55.255                              N.N.56.0    N.N.56-63.N      N.N.63.255                              N.N.64.0    N.N.64-71.N      N.N.71.255                              N.N.72.0    N.N.72-79.N      N.N.79.255                              N.N.80.0    N.N.80-87.N      N.N.87.255                              N.N.88.0    N.N.88-95.N      N.N.95.255                              N.N.96.0    N.N.96-103.N     N.N.103.255                              N.N.104.0   N.N.104-111.N    N.N.111.255                              N.N.112.0   N.N.112-119.N    N.N.119.255                              N.N.120.0   N.N.120-127.N    N.N.127.255                              N.N.128.0   N.N.128-135.N    N.N.135.255                              N.N.136.0   N.N.136-143.N    N.N.143.255                              N.N.144.0   N.N.144-151.N    N.N.151.255                              N.N.152.0   N.N.152-159.N    N.N.159.255                              N.N.160.0   N.N.160-167.N    N.N.167.255                              N.N.168.0   N.N.168-175.N    N.N.175.255                              N.N.176.0   N.N.176-183.N    N.N.183.255                              N.N.184.0   N.N.184-191.N    N.N.191.255                              N.N.192.0   N.N.192-199.N    N.N.199.255                              N.N.200.0   N.N.200-207.N    N.N.207.255                              N.N.208.0   N.N.208-215.N    N.N.215.255                              N.N.216.0   N.N.216-223.N    N.N.223.255                              N.N.224.0   N.N.224-231.N    N.N.231.255                              N.N.232.0   N.N.232-239.N    N.N.239.255                              N.N.240.0   N.N.240-247.N    N.N.247.255                              N.N.248.0   N.N.248-254.N    N.N.254.255255.255.252.0   64 nets     N.N.0.0     N.N.0-3.N        N.N.3.2556 bit subnet  1022          N.N.4.0     N.N.4-7.N        N.N.7.255                              N.N.8.0     N.N.8-11.N       N.N.11.255                              N.N.12.0    N.N.12-15.N      N.N.15.255                              N.N.240.0   N.N.240-243.N    N.N.243.255                              N.N.244.0   N.N.244-247.N    N.N.247.255                              N.N.248.0   N.N.248-251.N    N.N.251.255                              N.N.252.0   N.N.252-254.N    N.N.254.255255.255.254.0   128 nets    N.N.0.0     N.N.0-1.N        N.N.1.2557 bit subnet  510           N.N.2.0     N.N.2-3.N        N.N.3.255                              N.N.4.0     N.N.4-5.N        N.N.5.255                              N.N.250.0   N.N.250-251.N    N.N.251.255                              N.N.252.0   N.N.252-253.N    N.N.253.255Pummill & Manning            Informational                      [Page 4]

RFC 1878                      Subnet Table                 December 1995                              N.N.254.0   N.N.254.N        N.N.254.255255.255.255.0   255 nets    N.N.0.0     N.N.0.N          N.N.0.2558 bit subnet  253           N.N.1.0     N.N.1.N          N.N.1.255                              N.N.252.0   N.N.252.N        N.N.252.255                              N.N.253.0   N.N.253.N        N.N.253.255                              N.N.254.0   N.N.254.N        N.N.254.255   Table 1-2 represents traditional subnetting of a Class C network   address (which is identical to extended Class B subnets).Subnet Mask     # of nets    Net. Addr.  Host Addr Range  Brodcast Addr.Bits of Subnet  hosts/subnet255.255.255.128 2 nets     N.N.N.0     N.N.N.1-126      N.N.N.1271 bit Class C 126          N.N.N.128   N.N.N.129-254    N.N.N.2559 bit Class B255.255.255.192 4 nets     N.N.N.0     N.N.N.1-62       N.N.N.632 bit Class C 62           N.N.N.64    N.N.N.65-126     N.N.N.12710 bit Class B             N.N.N.128   N.N.N.129-190    N.N.N.191                             N.N.N.192   N.N.N.193-254    N.N.N.255255.255.255.224 8 nets     N.N.N.0     N.N.N.1-30       N.N.N.313 bit Class C 30           N.N.N.32    N.N.N.33-62      N.N.N.6311 bit Class B             N.N.N.64    N.N.N.65-94      N.N.N.95                             N.N.N.96    N.N.N.97-126     N.N.N.127                             N.N.N.128   N.N.N.129-158    N.N.N.159                             N.N.N.160   N.N.N.161-190    N.N.N.191                             N.N.N.192   N.N.N.193-222    N.N.N.223                             N.N.N.224   N.N.N.225-254    N.N.N.255255.255.255.240 16 nets    N.N.N.0     N.N.N.1-14       N.N.N.154 bit Class C 14           N.N.N.16    N.N.N.17-30      N.N.N.3112 bit Class B             N.N.N.32    N.N.N.33-46      N.N.N.47                             N.N.N.48    N.N.N.49-62      N.N.N.63                             N.N.N.64    N.N.N.65-78      N.N.N.79                             N.N.N.80    N.N.N.81-94      N.N.N.95                             N.N.N.96    N.N.N.97-110     N.N.N.111                             N.N.N.112   N.N.N.113-126    N.N.N.127                             N.N.N.128   N.N.N.129-142    N.N.N.143                             N.N.N.144   N.N.N.145-158    N.N.N.159                             N.N.N.160   N.N.N.161-174    N.N.N.175                             N.N.N.176   N.N.N.177-190    N.N.N.191                             N.N.N.192   N.N.N.193-206    N.N.N.207Pummill & Manning            Informational                      [Page 5]

RFC 1878                      Subnet Table                 December 1995                             N.N.N.208   N.N.N.209-222    N.N.N.223                             N.N.N.224   N.N.N.225-238    N.N.N.239                             N.N.N.240   N.N.N.241-254    N.N.N.255255.255.255.248 32 nets    N.N.N.0     N.N.N.1-6        N.N.N.75 bit Class C 6            N.N.N.8     N.N.N.9-14       N.N.N.1513 bit Class B             N.N.N.16    N.N.N.17-22      N.N.N.23                             N.N.N.24    N.N.N.25-30      N.N.N.31                             N.N.N.32    N.N.N.33-38      N.N.N.39                             N.N.N.40    N.N.N.41-46      N.N.N.47                             N.N.N.48    N.N.N.49-54      N.N.N.55                             N.N.N.56    N.N.N.57-62      N.N.N.63                             N.N.N.64    N.N.N.65-70      N.N.N.71                             N.N.N.72    N.N.N.73-78      N.N.N.79                             N.N.N.80    N.N.N.81-86      N.N.N.87                             N.N.N.88    N.N.N.89-94      N.N.N.95                             N.N.N.96    N.N.N.97-102     N.N.N.103                             N.N.N.104   N.N.N.105-110    N.N.N.111                             N.N.N.112   N.N.N.113-118    N.N.N.119                             N.N.N.120   N.N.N.121-126    N.N.N.127                             N.N.N.128   N.N.N.129-134    N.N.N.135                             N.N.N.136   N.N.N.137-142    N.N.N.143                             N.N.N.144   N.N.N.145-150    N.N.N.151                             N.N.N.152   N.N.N.153-158    N.N.N.159                             N.N.N.160   N.N.N.161-166    N.N.N.167                             N.N.N.168   N.N.N.169-174    N.N.N.175                             N.N.N.176   N.N.N.177-182    N.N.N.183                             N.N.N.184   N.N.N.185-190    N.N.N.191                             N.N.N.192   N.N.N.193-198    N.N.N.199                             N.N.N.200   N.N.N.201-206    N.N.N.207                             N.N.N.208   N.N.N.209-214    N.N.N.215                             N.N.N.216   N.N.N.217-222    N.N.N.223                             N.N.N.224   N.N.N.225-230    N.N.N.231                             N.N.N.232   N.N.N.233-238    N.N.N.239                             N.N.N.240   N.N.N.241-246    N.N.N.247                             N.N.N.248   N.N.N.249-254    N.N.N.255255.255.255.252 64 nets    N.N.N.0     N.N.N.1-2        N.N.N.36 bit Class C 2            N.N.N.4     N.N.N.5-6        N.N.N.714 bit Class B             N.N.N.8     N.N.N.9-10       N.N.N.11                             N.N.N.244   N.N.N.245-246    N.N.N.247                             N.N.N.248   N.N.N.249-250    N.N.N.251                             N.N.N.252   N.N.N.253-254    N.N.N.255Pummill & Manning            Informational                      [Page 6]

RFC 1878                      Subnet Table                 December 1995   For the sake of completeness within this memo, tables 2-1 and 2-2   illistrate some options for subnet/host partions within selected   block sizes using calculations which exclude all-zeros and all-ones   subnets [2].  Many vendors only support subnetting based upon this   premise.  This practice is obsolete!  Modern software will be able to   utilize all definable networks.Table 2-1 from a /16 block# bits          Mask            Effective Subnets       Effective Hosts========        =====           =================       ===============2               255.255.192.0 2                       163823               255.255.224.0 6                       81904               255.255.240.0 14                      40945               255.255.248.0 30                      20466               255.255.252.0 62                      10227               255.255.254.0 126                     5108               255.255.255.0 254                     2549               255.255.255.128 510                   12610              255.255.255.192 1022                  6211              255.255.255.224 2046                  3012              255.255.255.240 4094                  1413              255.255.255.248 8190                  614              255.255.255.252 16382                 2Table 2-2 from a /24 block# bits          Mask            Effective Subnets       Effective Hosts========        =====           =================       ===============2               255.255.255.192 2                     623               255.255.255.224 6                     304               255.255.255.240 14                    145               255.255.255.248 30                    66               255.255.255.252 62                    2*Subnet all zeroes and all ones excluded. (Obsolete)*Host all zeroes and all ones excluded.   (Obsolete)Pummill & Manning            Informational                      [Page 7]

RFC 1878                      Subnet Table                 December 1995References   [1] Mogul J., "BROADCASTING INTERNET DATAGRAMS IN THE PRESENCE OF       SUBNETS", STD 5,RFC 922, Stanford University, October 1984.   [2] Braden R., Editor, "Requirements for Internet Hosts --       Application and Support", STD 3,RFC 1123, IETF, October 1989.   [3] Fuller V., Li T., Yu J., and K. Varadhan, "Classless Inter-       Domain Routing (CIDR): an Address Assignment and Aggregation       Strategy",RFC 1519, BARRNet, cicso, Merit, OARnet, September       1993.   [4] Baker F., "Requirements for IP Version 4 Routers",RFC 1812,       cisco Systems, June 1995.   [5] Mogul J., and J. Postel, "Internet Standard Subnetting       Procedure", STD 5,RFC 950, Stanford, USC/Information Sciences       Institute, August 1985.Security Considerations   Security issues are not discussed in this memo.Authors' Addresses   Troy T. Pummill   Alantec   2115 O'Nel Drive   San Jose, CA  95131   USA   Phone: +1 408.467.4871   Fax:   +1 408.441.0272   EMail: trop@alantec.com   Bill Manning   Information Sciences Institute   University of Southern California   4676 Admiralty Way   Marina del Rey, CA 90292-6695   USA   Phone: +1 310-822-1511 x387   Fax:   +1 310-823-6714   EMail: bmanning@isi.eduPummill & Manning            Informational                      [Page 8]

[8]ページ先頭

©2009-2025 Movatter.jp