Network Working Group                                            J. CaseRequest for Comments: 1512                The University of Tennesse andUpdates:1285                                SNMP Research, Incorporated                                                          A. Rijsinghani                                           Digital Equipment Corporation                                                          September 1993FDDI Management Information BaseStatus of this Memo   This RFC specifies an Internet standards track protocol for the   Internet community, and requests discussion and suggestions for   improvements.  Please refer to the current edition of the "Internet   Official Protocol Standards" for the standardization state and status   of this protocol.  Distribution of this memo is unlimited.Abstract   This memo defines a portion of the Management Information Base (MIB)   for use with network management protocols in TCP/IP-based internets.   In particular, it defines objects for managing devices which   implement the FDDI based on the ANSI FDDI SMT 7.3 draft standard [8],   which has been forwarded for publication by the X3T9.5 committee.Table of Contents1. The Network Management Framework ......................21.1 Object Definitions ...................................21.2 Format of Definitions ................................22. Overview ..............................................22.1 Textual Conventions ..................................33. Changes fromRFC 1285 .................................34. Object Definitions ....................................44.1 The SMT Group ........................................64.2 The MAC Group ........................................174.3 The Enhanced MAC Counters Group ......................294.4 The PATH Group .......................................324.5 The PORT Group .......................................385. Acknowledgements ......................................486. References ............................................507. Security Considerations ...............................518. Authors' Addresses ....................................51Case & Rijsinghani                                              [Page 1]

RFC 1512                        FDDI MIB                  September 19931.  The Network Management Framework   The Internet-standard Network Management Framework consists of three   components.  They are:      o STD 16,RFC 1155 which defines the SMI, the mechanisms used for        describing and naming objects for the purpose of        management.  STD 16,RFC 1212 defines a more concise description        mechanism, which is wholly consistent with the SMI.      o STD 17,RFC 1213 defines MIB-II, the core set of managed objects        for the Internet suite of protocols.      o STD 15,RFC 1157 which defines the SNMP, the protocol used for        network access to managed objects.   The Framework permits new objects to be defined for the purpose of   experimentation and evaluation.1.1.  Object Definitions   Managed objects are accessed via a virtual information store, termed   the Management Information Base or MIB.  Objects in the MIB are   defined using the subset of Abstract Syntax Notation One (ASN.1)   defined in the SMI.  In particular, each object object type is named   by an OBJECT IDENTIFIER, an administratively assigned name.  The   object type together with an object instance serves to uniquely   identify a specific instantiation of the object.  For human   convenience, we often use a textual string, termed the descriptor, to   refer to the object type.1.2.  Format of DefinitionsSection 4 contains contains the specification of all object types   contained in this MIB module.  The object types are defined using the   conventions defined in the SMI, as amended by the extensions   specified in [7].2.  Overview   This document defines the managed objects for FDDI devices which are   to be accessible via the Simple Network Management Protocol (SNMP).   At present, this applies to these values of the ifType variable in   the Internet-standard MIB:               fddi(15)   For these interfaces, the value of the ifSpecific variable in theCase & Rijsinghani                                              [Page 2]

RFC 1512                        FDDI MIB                  September 1993   MIB-II [4] has the OBJECT IDENTIFIER value:               fddimib    OBJECT IDENTIFIER ::= { fddi 73 }   The definitions of the objects presented here draws heavily from   related work in the ANSI X3T9.5 committee and the SMT subcommittee of   that committee [8].  In fact, the definitions of the managed objects   in this document are, to the maximum extent possible, identical to   those identified by the ANSI committee.  The semantics of each   managed object should be the same with syntactic changes made as   necessary to recast the objects in terms of the Internet-standard SMI   and MIB so as to be compatible with the SNMP.  Examples of these   syntactic changes include remapping booleans to enumerated integers,   remapping bit strings to octet strings, and the like.  In addition,   the naming of the objects was changed to achieve compatibility.   These minimal syntactic changes with no semantic changes should allow   implementations of SNMP manageable FDDI systems to share   instrumentation with other network management schemes and thereby   minimize implementation cost.  In addition, the translation of   information conveyed by managed objects from one network management   scheme to another is eased by these shared definitions.   Only the essential variables, as indicated by their mandatory status   in the ANSI specification, were retained in this document.  The   importance of variables which have an optional status in the ANSI   specification were perceived as being less widely accepted.2.1.  Textual Conventions   Several new datatypes are introduced as a textual convention in this   MIB document.  These textual conventions enhance the readability of   the document and ease comparisons with its ANSI counterpart.  It   should be noted that the introduction of these textual conventions   has no effect on either the syntax or the semantics of any managed   objects.  The use of these is merely an artifact of the explanatory   method used.  Objects defined in terms of one of these methods are   always encoded by means of the rules that define the primitive type.   Hence, no changes to the SMI or the SNMP are necessary to accommodate   these textual conventions which are adopted merely for the   convenience of readers and writers in pursuit of the elusive goal of   clear, concise, and unambiguous MIB documents.3.  Changes fromRFC 1285   The changes fromRFC 1285 [2] to this document, based on changes from   ANSI SMT 6.2 to SMT 7.3, were so numerous that the objects in this   MIB module are located on a different branch of the MIB tree.  NoCase & Rijsinghani                                              [Page 3]

RFC 1512                        FDDI MIB                  September 1993   assumptions should be made about compatibility withRFC 1285.4.  Object Definitions          FDDI-SMT73-MIB DEFINITIONS ::= BEGIN          IMPORTS                  Counter                      FROMRFC1155-SMI                  OBJECT-TYPE                      FROMRFC-1212;          --  This MIB module uses the extended OBJECT-TYPE macro as          --  defined in [7].          -- this is the FDDI MIB module          fddi    OBJECT IDENTIFIER ::= { transmission 15 }          fddimib   OBJECT IDENTIFIER ::= { fddi 73 }          -- textual conventions          FddiTimeNano ::= INTEGER (0..2147483647)          -- This data type specifies 1 nanosecond units as          -- an integer value.          --          -- NOTE: The encoding is normal integer representation, not          -- two's complement.  Since this type is used for variables          -- which are encoded as TimerTwosComplement in the ANSI          -- specification, two operations need to be performed on such          -- variables to convert from ANSI form to SNMP form:          --          -- 1) Convert from two's complement to normal integer          --    representation          -- 2) Multiply by 80 to convert from 80 nsec to 1 nsec units          --          -- No resolution is lost.  Moreover, the objects for which          -- this data type is used effectively do not lose any range          -- due to the lower maximum value since they do not require          -- the full range.          --          -- Example: If fddimibMACTReq had a value of 8 ms, it would          -- be stored in ANSI TimerTwosComplement format as 0xFFFE7960          -- [8 ms is 100000 in 80 nsec units, which is then converted          -- to two's complement] but be reported as 8000000 in SNMP          -- since it is encoded here as FddiTimeNano.Case & Rijsinghani                                              [Page 4]

RFC 1512                        FDDI MIB                  September 1993          FddiTimeMilli ::= INTEGER (0..2147483647)          -- This data type is used for some FDDI timers. It specifies          -- time in 1 millisecond units, in normal integer          -- representation.          FddiResourceId ::= INTEGER (0..65535)          -- This data type is used to refer to an instance of a  MAC,          -- PORT, or PATH Resource ID.  Indexing begins          -- at 1.  Zero is used to indicate the absence of a resource.          FddiSMTStationIdType ::= OCTET STRING (SIZE (8))          -- The unique identifier for the FDDI station.  This is a          -- string of 8 octets, represented as X' yy yy xx xx xx xx          -- xx xx' with the low order 6 octet (xx) from a unique IEEE          -- assigned address.  The high order two bits of the IEEE          -- address, the group address bit and the administration bit          -- (Universal/Local) bit should both be zero.  The first two          -- octets, the yy octets, are implementor-defined.          --          -- The representation of the address portion of the station id          -- is in the IEEE (ANSI/IEEE P802.1A) canonical notation for          -- 48 bit addresses.  The canonical form is a 6-octet string          -- where the first octet contains the first 8 bits of the          -- address, with the I/G(Individual/Group) address bit as the          -- least significant bit and the  U/L (Universal/Local) bit          -- as the next more significant bit, and so on.  Note that          -- addresses in the ANSI FDDI standard SMT frames are          -- represented in FDDI MAC order.          FddiMACLongAddressType ::= OCTET STRING (SIZE (6))          -- The representation of long MAC addresses as management          -- values is in the IEEE (ANSI/IEEE P802.1A) canonical          -- notation for 48 bit addresses.  The canonical form is a          -- 6-octet string where the first octet contains the first 8          -- bits of the address, with the I/G (Individual/Group)          -- address bit as the least significant bit and the  U/L          -- (Universal/Local) bit as the next more significant bit,          -- and so on.  Note that the addresses in the SMT frames are          -- represented in FDDI MAC order.          -- groups in the FDDI MIB module          fddimibSMT          OBJECT IDENTIFIER ::= { fddimib 1 }          fddimibMAC          OBJECT IDENTIFIER ::= { fddimib 2 }          fddimibMACCounters  OBJECT IDENTIFIER ::= { fddimib 3 }Case & Rijsinghani                                              [Page 5]

RFC 1512                        FDDI MIB                  September 1993          fddimibPATH         OBJECT IDENTIFIER ::= { fddimib 4 }          fddimibPORT         OBJECT IDENTIFIER ::= { fddimib 5 }          -- the SMT group          -- Implementation of the SMT group is mandatory for all          -- systems which implement manageable FDDI subsystems.          fddimibSMTNumber OBJECT-TYPE              SYNTAX  INTEGER (0..65535)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The number of SMT implementations (regardless of                      their current state) on this network management                      application entity.  The value for this variable                      must remain constant at least from one re-                      initialization of the entity's network management                      system to the next re-initialization."              ::= { fddimibSMT  1 }          -- the SMT table          fddimibSMTTable OBJECT-TYPE              SYNTAX  SEQUENCE OF FddimibSMTEntry              ACCESS  not-accessible              STATUS  mandatory              DESCRIPTION                      "A list of SMT entries.  The number of entries                      shall not exceed the value of fddimibSMTNumber."              ::= { fddimibSMT  2 }          fddimibSMTEntry OBJECT-TYPE              SYNTAX  FddimibSMTEntry              ACCESS  not-accessible              STATUS  mandatory              DESCRIPTION                      "An SMT entry containing information common to a                      given SMT."              INDEX   { fddimibSMTIndex }              ::= { fddimibSMTTable 1 }          FddimibSMTEntry ::=              SEQUENCE {                  fddimibSMTIndex                      INTEGER,Case & Rijsinghani                                              [Page 6]

RFC 1512                        FDDI MIB                  September 1993                  fddimibSMTStationId                      FddiSMTStationIdType,                  fddimibSMTOpVersionId                      INTEGER,                  fddimibSMTHiVersionId                      INTEGER,                  fddimibSMTLoVersionId                      INTEGER,                  fddimibSMTUserData                      OCTET STRING,                  fddimibSMTMIBVersionId                      INTEGER,                  fddimibSMTMACCts                      INTEGER,                  fddimibSMTNonMasterCts                      INTEGER,                  fddimibSMTMasterCts                      INTEGER,                  fddimibSMTAvailablePaths                      INTEGER,                  fddimibSMTConfigCapabilities                      INTEGER,                  fddimibSMTConfigPolicy                      INTEGER,                  fddimibSMTConnectionPolicy                      INTEGER,                  fddimibSMTTNotify                      INTEGER,                  fddimibSMTStatRptPolicy                      INTEGER,                  fddimibSMTTraceMaxExpiration                      FddiTimeMilli,                  fddimibSMTBypassPresent                      INTEGER,                  fddimibSMTECMState                      INTEGER,                  fddimibSMTCFState                      INTEGER,                  fddimibSMTRemoteDisconnectFlag                      INTEGER,                  fddimibSMTStationStatus                      INTEGER,                  fddimibSMTPeerWrapFlag                      INTEGER,                  fddimibSMTTimeStamp                      FddiTimeMilli,                  fddimibSMTTransitionTimeStamp                      FddiTimeMilli,Case & Rijsinghani                                              [Page 7]

RFC 1512                        FDDI MIB                  September 1993                  fddimibSMTStationAction                      INTEGER              }          fddimibSMTIndex OBJECT-TYPE              SYNTAX  INTEGER (1..65535)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "A unique value for each SMT.  The value for each                      SMT must remain constant at least from one re-                      initialization of the entity's network management                      system to the next re-initialization."              ::= { fddimibSMTEntry 1 }          fddimibSMTStationId OBJECT-TYPE              SYNTAX  FddiSMTStationIdType -- OCTET STRING (SIZE (8))              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "Used to uniquely identify an FDDI station."              REFERENCE                      "ANSI { fddiSMT 11 }"              ::= { fddimibSMTEntry 2 }          fddimibSMTOpVersionId OBJECT-TYPE              SYNTAX  INTEGER (1..65535)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The version that this station is using for its                      operation (refer to ANSI 7.1.2.2). The value of                      this variable is 2 for this SMT revision."              REFERENCE                      "ANSI { fddiSMT 13 }"              ::= { fddimibSMTEntry 3 }          fddimibSMTHiVersionId OBJECT-TYPE              SYNTAX  INTEGER (1..65535)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The highest version of SMT that this station                      supports (refer to ANSI 7.1.2.2)."              REFERENCE                      "ANSI { fddiSMT 14 }"              ::= { fddimibSMTEntry 4 }Case & Rijsinghani                                              [Page 8]

RFC 1512                        FDDI MIB                  September 1993          fddimibSMTLoVersionId OBJECT-TYPE              SYNTAX  INTEGER (1..65535)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The lowest version of SMT that this station                      supports (refer to ANSI 7.1.2.2)."              REFERENCE                      "ANSI { fddiSMT 15 }"              ::= { fddimibSMTEntry 5 }          fddimibSMTUserData OBJECT-TYPE              SYNTAX  OCTET STRING (SIZE (32))              ACCESS  read-write              STATUS  mandatory              DESCRIPTION                      "This variable contains 32 octets of user defined                      information. The information shall be an ASCII                      string."              REFERENCE                      "ANSI { fddiSMT 17 }"              ::= { fddimibSMTEntry 6 }          fddimibSMTMIBVersionId OBJECT-TYPE              SYNTAX  INTEGER (0..65535)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The version of the FDDI MIB of this station.  The                      value of this variable is 1 for this SMT                      revision."              REFERENCE                      "ANSI { fddiSMT 18 }"              ::= { fddimibSMTEntry 7 }          fddimibSMTMACCts OBJECT-TYPE              SYNTAX  INTEGER (0..255)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The number of MACs in this station or                      concentrator."              REFERENCE                      "ANSI { fddiSMT 21 }"              ::= { fddimibSMTEntry 8 }          fddimibSMTNonMasterCts OBJECT-TYPE              SYNTAX  INTEGER (0..2)Case & Rijsinghani                                              [Page 9]

RFC 1512                        FDDI MIB                  September 1993              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The value of this variable is the number of A, B,                      and S ports in this station or concentrator."              REFERENCE                      "ANSI { fddiSMT 22 }"              ::= { fddimibSMTEntry 9 }          fddimibSMTMasterCts OBJECT-TYPE              SYNTAX  INTEGER (0..255)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The number of M Ports in a node. If the node is                      not a concentrator, the value of the variable is                      zero."              REFERENCE                      "ANSI { fddiSMT 23 }"              ::= { fddimibSMTEntry 10 }          fddimibSMTAvailablePaths OBJECT-TYPE              SYNTAX  INTEGER (0..7)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "A value that indicates the PATH types available                      in the station.                      The value is a sum.  This value initially takes                      the value zero, then for each type of PATH that                      this node has available, 2 raised to a power is                      added to the sum.  The powers are according to the                      following table:                               Path   Power                            Primary     0                          Secondary     1                              Local     2                      For example, a station having Primary and Local                      PATHs available would have a value of 5 (2**0 +                      2**2)."              REFERENCE                      "ANSI { fddiSMT 24 }"              ::= { fddimibSMTEntry 11 }          fddimibSMTConfigCapabilities OBJECT-TYPECase & Rijsinghani                                             [Page 10]

RFC 1512                        FDDI MIB                  September 1993              SYNTAX  INTEGER (0..3)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "A value that indicates the configuration                      capabilities of a node. The 'Hold Available' bit                      indicates the support of the optional Hold                      Function, which is controlled by                      fddiSMTConfigPolicy.  The 'CF-Wrap-AB' bit                      indicates that the station has the capability of                      performing a wrap_ab (refer to ANSI SMT 9.7.2.2).                      The value is a sum.  This value initially takes                      the value zero, then for each of the configuration                      policies currently enforced on the node, 2 raised                      to a power is added to the sum.  The powers are                      according to the following table:                                 Policy   Power                          holdAvailable     0                             CF-Wrap-AB     1 "              REFERENCE                      "ANSI { fddiSMT 25 }"              ::= { fddimibSMTEntry 12 }          fddimibSMTConfigPolicy OBJECT-TYPE              SYNTAX  INTEGER (0..1)              ACCESS  read-write              STATUS  mandatory              DESCRIPTION                      "A value that indicates the configuration policies                      currently desired in a node.  'Hold' is one of the                      terms used for the Hold Flag, an optional ECM flag                      used to enable the optional Hold policy.                      The value is a sum.  This value initially takes                      the value zero, then for each of the configuration                      policies currently enforced on the node, 2 raised                      to a power is added to the sum.  The powers are                      according to the following table:                                     Policy   Power                          configurationhold     0 "              REFERENCE                      "ANSI { fddiSMT 26 }"              ::= { fddimibSMTEntry 13 }          fddimibSMTConnectionPolicy OBJECT-TYPECase & Rijsinghani                                             [Page 11]

RFC 1512                        FDDI MIB                  September 1993              SYNTAX  INTEGER (32768..65535)              ACCESS  read-write              STATUS  mandatory              DESCRIPTION                      "A value representing the connection policies in                      effect in a node. A station sets the corresponding                      bit for each of the connection types that it                      rejects. The letter designations, X and Y, in the                      'rejectX-Y' names have the following significance:                      X represents the PC-Type of the local PORT and Y                      represents the PC_Type of the adjacent PORT                      (PC_Neighbor). The evaluation of Connection-                      Policy (PC-Type, PC-Neighbor) is done to determine                      the setting of T- Val(3) in the PC-Signalling                      sequence (refer to ANSI 9.6.3). Note that Bit 15,                      (rejectM-M), is always set and cannot be cleared.                      The value is a sum.  This value initially takes                      the value zero, then for each of the connection                      policies currently enforced on the node, 2 raised                      to a power is added to the sum.  The powers are                      according to the following table:                             Policy   Power                          rejectA-A     0                          rejectA-B     1                          rejectA-S     2                          rejectA-M     3                          rejectB-A     4                          rejectB-B     5                          rejectB-S     6                          rejectB-M     7                          rejectS-A     8                          rejectS-B     9                          rejectS-S     10                          rejectS-M     11                          rejectM-A     12                          rejectM-B     13                          rejectM-S     14                          rejectM-M     15 "              REFERENCE                      "ANSI { fddiSMT 27 }"              ::= { fddimibSMTEntry 14 }          fddimibSMTTNotify OBJECT-TYPE              SYNTAX  INTEGER (2..30)              ACCESS  read-write              STATUS  mandatoryCase & Rijsinghani                                             [Page 12]

RFC 1512                        FDDI MIB                  September 1993              DESCRIPTION                      "The timer, expressed in seconds, used in the                      Neighbor Notification protocol. It has a range of                      2 seconds to 30 seconds, and its default value is                      30 seconds (refer to ANSI SMT 8.2)."              REFERENCE                      "ANSI { fddiSMT 29 }"              ::= { fddimibSMTEntry 15 }          fddimibSMTStatRptPolicy OBJECT-TYPE              SYNTAX  INTEGER { true(1), false(2) }              ACCESS  read-write              STATUS  mandatory              DESCRIPTION                      "If true, indicates that the node will generate                      Status Reporting Frames for its implemented events                      and conditions. It has an initial value of true.                      This variable determines the value of the                      SR_Enable Flag (refer to ANSI SMT 8.3.2.1)."              REFERENCE                      "ANSI { fddiSMT 30 }"              ::= { fddimibSMTEntry 16 }          fddimibSMTTraceMaxExpiration OBJECT-TYPE              SYNTAX  FddiTimeMilli              ACCESS  read-write              STATUS  mandatory              DESCRIPTION                      "Reference Trace_Max (refer to ANSI SMT                      9.4.4.2.2)."              REFERENCE                      "ANSI { fddiSMT 31 }"              ::= { fddimibSMTEntry 17 }          fddimibSMTBypassPresent OBJECT-TYPE              SYNTAX  INTEGER { true(1), false(2) }              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "A flag indicating if the station has a bypass on                      its AB port pair."              REFERENCE                      "ANSI { fddiSMT 34 }"              ::= { fddimibSMTEntry 18 }          fddimibSMTECMState OBJECT-TYPE              SYNTAX  INTEGER {                          ec0(1), -- OutCase & Rijsinghani                                             [Page 13]

RFC 1512                        FDDI MIB                  September 1993                          ec1(2), -- In                          ec2(3), -- Trace                          ec3(4), -- Leave                          ec4(5), -- Path_Test                          ec5(6), -- Insert                          ec6(7), -- Check                          ec7(8)  -- Deinsert                      }              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "Indicates the current state of the ECM state                      machine (refer to ANSI SMT 9.5.2)."              REFERENCE                      "ANSI { fddiSMT 41 }"              ::= { fddimibSMTEntry 19 }          fddimibSMTCFState OBJECT-TYPE              SYNTAX  INTEGER {                          cf0(1),   -- isolated                          cf1(2),   -- local_a                          cf2(3),   -- local_b                          cf3(4),   -- local_ab                          cf4(5),   -- local_s                          cf5(6),   -- wrap_a                          cf6(7),   -- wrap_b                          cf7(8),   -- wrap_ab                          cf8(9),   -- wrap_s                          cf9(10),  -- c_wrap_a                          cf10(11), -- c_wrap_b                          cf11(12), -- c_wrap_s                          cf12(13)  -- thru                      }              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The attachment configuration for the station or                      concentrator (refer to ANSI SMT 9.7.2.2)."              REFERENCE                      "ANSI { fddiSMT 42 }"              ::= { fddimibSMTEntry 20 }          fddimibSMTRemoteDisconnectFlag OBJECT-TYPE              SYNTAX  INTEGER { true(1), false(2) }              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "A flag indicating that the station was remotelyCase & Rijsinghani                                             [Page 14]

RFC 1512                        FDDI MIB                  September 1993                      disconnected from the network as a result of                      receiving an fddiSMTAction, disconnect (refer to                      ANSI SMT 6.4.5.3) in a Parameter Management Frame.                      A station requires a Connect Action to rejoin and                      clear the flag (refer to ANSI SMT 6.4.5.2)."              REFERENCE                      "ANSI { fddiSMT 44 }"              ::= { fddimibSMTEntry 21 }          fddimibSMTStationStatus OBJECT-TYPE              SYNTAX  INTEGER { concatenated(1), separated(2), thru(3) }              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The current status of the primary and secondary                      paths within this station."              REFERENCE                      "ANSI { fddiSMT 45 }"              ::= { fddimibSMTEntry 22 }          fddimibSMTPeerWrapFlag OBJECT-TYPE              SYNTAX  INTEGER { true(1), false(2) }              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "This variable assumes the value of the                      PeerWrapFlag in CFM (refer to ANSI SMT                      9.7.2.4.4)."              REFERENCE                      "ANSI { fddiSMT 46 }"              ::= { fddimibSMTEntry 23 }          fddimibSMTTimeStamp OBJECT-TYPE              SYNTAX  FddiTimeMilli              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "This variable assumes the value of TimeStamp                      (refer to ANSI SMT 8.3.2.1)."              REFERENCE                      "ANSI { fddiSMT 51 }"              ::= { fddimibSMTEntry 24 }          fddimibSMTTransitionTimeStamp OBJECT-TYPE              SYNTAX  FddiTimeMilli              ACCESS  read-only              STATUS  mandatory              DESCRIPTIONCase & Rijsinghani                                             [Page 15]

RFC 1512                        FDDI MIB                  September 1993                      "This variable assumes the value of                      TransitionTimeStamp (refer to ANSI SMT 8.3.2.1)."              REFERENCE                      "ANSI { fddiSMT 52 }"              ::= { fddimibSMTEntry 25 }          fddimibSMTStationAction OBJECT-TYPE              SYNTAX  INTEGER {                          other(1),               -- none of the following                          connect(2),                          disconnect(3),                          path-Test(4),                          self-Test(5),                          disable-a(6),                          disable-b(7),                          disable-m(8)                      }              ACCESS  read-write              STATUS  mandatory              DESCRIPTION                      "This object, when read, always returns a value of                      other(1).  The behavior of setting this variable                      to each of the acceptable values is as follows:                           other(1): Results in an appropriate error.                           connect(2): Generates a Connect signal to ECM                                to begin a connection sequence. See ANSI                                Ref 9.4.2.                           disconnect(3): Generates a Disconnect signal                                to ECM. see ANSI Ref 9.4.2.                           path-Test(4): Initiates a station Path_Test.                                The Path_Test variable (see ANSI Ref                                9.4.1) is set to 'Testing'. The results                                of this action are not specified in this                                standard.                           self-Test(5): Initiates a station Self_Test.                                The results of this action are not                                specified in this standard.                           disable-a(6): Causes a PC_Disable on the A                                port if the A port mode is peer.                           disable-b(7): Causes a PC_Disable on the B                                port if the B port mode is peer.                           disable-m(8): Causes a PC_Disable on all M                                ports.                      Attempts to set this object to all other values                      results in an appropriate error.  The result of                      setting this variable to path-Test(4) or self-Case & Rijsinghani                                             [Page 16]

RFC 1512                        FDDI MIB                  September 1993                      Test(5) is implementation-specific."              REFERENCE                      "ANSI { fddiSMT 60 }"              ::= { fddimibSMTEntry 26 }          -- the MAC group          -- Implementation of the MAC Group is mandatory for all          -- systems which implement manageable FDDI subsystems.          fddimibMACNumber OBJECT-TYPE              SYNTAX  INTEGER (0..65535)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The total number of MAC implementations (across                      all SMTs) on this network management application                      entity.  The value for this variable must remain                      constant at least from one re-initialization of                      the entity's network management system to the next                      re-initialization."              ::= { fddimibMAC  1 }          -- the MAC table          fddimibMACTable OBJECT-TYPE              SYNTAX  SEQUENCE OF FddimibMACEntry              ACCESS  not-accessible              STATUS  mandatory              DESCRIPTION                      "A list of MAC entries.  The number of entries                      shall not exceed the value of fddimibMACNumber."              ::= { fddimibMAC  2 }          fddimibMACEntry OBJECT-TYPE              SYNTAX  FddimibMACEntry              ACCESS  not-accessible              STATUS  mandatory              DESCRIPTION                      "A MAC entry containing information common to a                      given MAC."              INDEX   { fddimibMACSMTIndex, fddimibMACIndex }              ::= { fddimibMACTable 1 }          FddimibMACEntry ::=              SEQUENCE {                  fddimibMACSMTIndexCase & Rijsinghani                                             [Page 17]

RFC 1512                        FDDI MIB                  September 1993                          INTEGER,                  fddimibMACIndex                          INTEGER,                  fddimibMACIfIndex                          INTEGER,                  fddimibMACFrameStatusFunctions                          INTEGER,                  fddimibMACTMaxCapability                          FddiTimeNano,                  fddimibMACTVXCapability                          FddiTimeNano,                  fddimibMACAvailablePaths                          INTEGER,                  fddimibMACCurrentPath                          INTEGER,                  fddimibMACUpstreamNbr                          FddiMACLongAddressType,                  fddimibMACDownstreamNbr                          FddiMACLongAddressType,                  fddimibMACOldUpstreamNbr                          FddiMACLongAddressType,                  fddimibMACOldDownstreamNbr                          FddiMACLongAddressType,                  fddimibMACDupAddressTest                          INTEGER,                  fddimibMACRequestedPaths                          INTEGER,                  fddimibMACDownstreamPORTType                          INTEGER,                  fddimibMACSMTAddress                          FddiMACLongAddressType,                  fddimibMACTReq                          FddiTimeNano,                  fddimibMACTNeg                          FddiTimeNano,                  fddimibMACTMax                          FddiTimeNano,                  fddimibMACTvxValue                          FddiTimeNano,                  fddimibMACFrameCts                          Counter,                  fddimibMACCopiedCts                          Counter,                  fddimibMACTransmitCts                          Counter,                  fddimibMACErrorCts                          Counter,                  fddimibMACLostCtsCase & Rijsinghani                                             [Page 18]

RFC 1512                        FDDI MIB                  September 1993                          Counter,                  fddimibMACFrameErrorThreshold                          INTEGER,                  fddimibMACFrameErrorRatio                          INTEGER,                  fddimibMACRMTState                          INTEGER,                  fddimibMACDaFlag                          INTEGER,                  fddimibMACUnaDaFlag                          INTEGER,                  fddimibMACFrameErrorFlag                          INTEGER,                  fddimibMACMAUnitdataAvailable                          INTEGER,                  fddimibMACHardwarePresent                          INTEGER,                  fddimibMACMAUnitdataEnable                          INTEGER              }          fddimibMACSMTIndex OBJECT-TYPE              SYNTAX  INTEGER (1..65535)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The value of the SMT index associated with this                      MAC."              ::= { fddimibMACEntry 1 }          fddimibMACIndex OBJECT-TYPE              SYNTAX  INTEGER (1..65535)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "Index variable for uniquely identifying the MAC                      object instances, which is the same as the                      corresponding resource index in SMT."              REFERENCE                      "ANSI { fddiMAC 34 }"              ::= { fddimibMACEntry 2 }          fddimibMACIfIndex OBJECT-TYPE              SYNTAX  INTEGER (1..65535)              ACCESS  read-only              STATUS  mandatory              DESCRIPTIONCase & Rijsinghani                                             [Page 19]

RFC 1512                        FDDI MIB                  September 1993                      "The value of the MIB-II ifIndex corresponding to                      this MAC.  If none is applicable, 0 is returned."              REFERENCE                      "MIB-II"              ::= { fddimibMACEntry 3 }          fddimibMACFrameStatusFunctions OBJECT-TYPE              SYNTAX  INTEGER (0..7)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "Indicates the MAC's optional Frame Status                      processing functions.                      The value is a sum.  This value initially takes                      the value zero, then for each function present, 2                      raised to a power is added to the sum.  The powers                      are according to the following table:                           function   Power                       fs-repeating     0                         fs-setting     1                        fs-clearing     2 "              REFERENCE                      "ANSI { fddiMAC 11 }"              ::= { fddimibMACEntry 4 }          fddimibMACTMaxCapability OBJECT-TYPE              SYNTAX  FddiTimeNano              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "Indicates the maximum time value of fddiMACTMax                      that this MAC can support."              REFERENCE                      "ANSI { fddiMAC 13 }"              ::= { fddimibMACEntry 5 }          fddimibMACTVXCapability OBJECT-TYPE              SYNTAX  FddiTimeNano              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "Indicates the maximum time value of                      fddiMACTvxValue that this MAC can support."              REFERENCE                      "ANSI { fddiMAC 14 }"              ::= { fddimibMACEntry 6 }Case & Rijsinghani                                             [Page 20]

RFC 1512                        FDDI MIB                  September 1993          fddimibMACAvailablePaths OBJECT-TYPE              SYNTAX  INTEGER (0..7)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "Indicates the paths available for this MAC (refer                      to ANSI SMT 9.7.7).                      The value is a sum.  This value initially takes                      the value zero, then for each type of PATH that                      this MAC has available, 2 raised to a power is                      added to the sum.  The powers are according to the                      following table:                               Path   Power                            Primary     0                          Secondary     1                              Local     2 "              REFERENCE                      "ANSI { fddiMAC 22 }"              ::= { fddimibMACEntry 7 }          fddimibMACCurrentPath OBJECT-TYPE              SYNTAX  INTEGER {                          isolated(1),                          local(2),                          secondary(3),                          primary(4),                          concatenated(5),                          thru(6)                      }              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "Indicates the Path into which this MAC is                      currently inserted (refer to ANSI 9.7.7)."              REFERENCE                      "ANSI { fddiMAC 23 }"              ::= { fddimibMACEntry 8 }          fddimibMACUpstreamNbr OBJECT-TYPE              SYNTAX  FddiMACLongAddressType -- OCTET STRING (SIZE (6))              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The MAC's upstream neighbor's long individual MAC                      address. It has an initial value of the SMT-                      Unknown-MAC Address and is only modified asCase & Rijsinghani                                             [Page 21]

RFC 1512                        FDDI MIB                  September 1993                      specified by the Neighbor Information Frame                      protocol (refer to ANSI SMT 7.2.1 and 8.2)."              REFERENCE                      "ANSI { fddiMAC 24 }"              ::= { fddimibMACEntry 9 }          fddimibMACDownstreamNbr OBJECT-TYPE              SYNTAX  FddiMACLongAddressType -- OCTET STRING (SIZE (6))              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The MAC's downstream neighbor's long individual                      MAC address. It has an initial value of the SMT-                      Unknown-MAC Address and is only modified as                      specified by the Neighbor Information Frame                      protocol (refer to ANSI SMT 7.2.1 and 8.2)."              REFERENCE                      "ANSI { fddiMAC 25 }"              ::= { fddimibMACEntry 10 }          fddimibMACOldUpstreamNbr OBJECT-TYPE              SYNTAX  FddiMACLongAddressType -- OCTET STRING (SIZE (6))              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The previous value of the MAC's upstream                      neighbor's long individual MAC address. It has an                      initial value of the SMT-Unknown- MAC Address and                      is only modified as specified by the Neighbor                      Information Frame protocol (refer to ANSI SMT                      7.2.1 and 8.2)."              REFERENCE                      "ANSI { fddiMAC 26 }"              ::= { fddimibMACEntry 11 }          fddimibMACOldDownstreamNbr OBJECT-TYPE              SYNTAX  FddiMACLongAddressType -- OCTET STRING (SIZE (6))              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The previous value of the MAC's downstream                      neighbor's long individual MAC address. It has an                      initial value of the SMT- Unknown-MAC Address and                      is only modified as specified by the Neighbor                      Information Frame protocol (refer to ANSI SMT                      7.2.1 and 8.2)."              REFERENCE                      "ANSI { fddiMAC 27 }"Case & Rijsinghani                                             [Page 22]

RFC 1512                        FDDI MIB                  September 1993              ::= { fddimibMACEntry 12 }          fddimibMACDupAddressTest OBJECT-TYPE              SYNTAX  INTEGER { none(1), pass(2), fail(3) }              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The Duplicate Address Test flag, Dup_Addr_Test                      (refer to ANSI 8.2)."              REFERENCE                      "ANSI { fddiMAC 29 }"              ::= { fddimibMACEntry 13 }          fddimibMACRequestedPaths OBJECT-TYPE              SYNTAX  INTEGER  (0..255)              ACCESS  read-write              STATUS  mandatory              DESCRIPTION                      "List of permitted Paths which specifies the                      Path(s) into which the MAC may be inserted (refer                      to ansi SMT 9.7).                      The value is a sum which represents the individual                      paths that are desired.  This value initially                      takes the value zero, then for each type of PATH                      that this node is, 2 raised to a power is added to                      the sum.  The powers are according to the                      following table:                                         Path   Power                                        local     0                          secondary-alternate     1                            primary-alternate     2                       concatenated-alternate     3                          secondary-preferred     4                            primary-preferred     5                       concatenated-preferred     6                                         thru     7 "              REFERENCE                      "ANSI { fddiMAC 32 }"              ::= { fddimibMACEntry 14 }          fddimibMACDownstreamPORTType OBJECT-TYPE              SYNTAX  INTEGER { a(1), b(2), s(3), m(4), none(5) }              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "Indicates the PC-Type of the first port that isCase & Rijsinghani                                             [Page 23]

RFC 1512                        FDDI MIB                  September 1993                      downstream of this MAC (the exit port)."              REFERENCE                      "ANSI { fddiMAC 33 }"              ::= { fddimibMACEntry 15 }          fddimibMACSMTAddress OBJECT-TYPE              SYNTAX  FddiMACLongAddressType -- OCTET STRING (SIZE (6))              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The 48-bit individual address of the MAC used for                      SMT frames."              REFERENCE                      "ANSI { fddiMAC 41 }"              ::= { fddimibMACEntry 16 }          fddimibMACTReq OBJECT-TYPE              SYNTAX  FddiTimeNano              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "This variable is the T_Req_value passed to the                      MAC.  Without having detected a duplicate, the                      time value of this variable shall assume the                      maximum supported time value which is less than or                      equal to the time value of fddiPATHMaxT-Req.  When                      a MAC has an address detected as a duplicate, it                      may use a time value for this variable greater                      than the time value of fddiPATHTMaxLowerBound.  A                      station shall cause claim when the new T_Req may                      cause the value of T_Neg to change in the claim                      process, (i.e., time value new T_Req < T_Neg, or                      old T_Req = T_Neg)."              REFERENCE                      "ANSI { fddiMAC 51 }"              ::= { fddimibMACEntry 17 }          fddimibMACTNeg OBJECT-TYPE              SYNTAX  FddiTimeNano              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "It is reported as a FddiTimeNano number."              REFERENCE                      "ANSI { fddiMAC 52 }"              ::= { fddimibMACEntry 18 }          fddimibMACTMax OBJECT-TYPECase & Rijsinghani                                             [Page 24]

RFC 1512                        FDDI MIB                  September 1993              SYNTAX  FddiTimeNano              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "This variable is the T_Max_value passed to the                      MAC.  The time value of this variable shall assume                      the minimum suported time value which is greater                      than or equal to the time value of fddiPATHT-                      MaxLowerBound"              REFERENCE                      "ANSI { fddiMAC 53 }"              ::= { fddimibMACEntry 19 }          fddimibMACTvxValue OBJECT-TYPE              SYNTAX  FddiTimeNano              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "This variable is the TVX_value passed to the MAC.                      The time value of this variable shall assume the                      minimum suported time value which is greater than                      or equal to the time value of                      fddiPATHTVXLowerBound."              REFERENCE                      "ANSI { fddiMAC 54 }"              ::= { fddimibMACEntry 20 }          fddimibMACFrameCts OBJECT-TYPE              SYNTAX  Counter              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "A count of the number of frames received by this                      MAC (refer to ANSI MAC 7.5.1)."              REFERENCE                      "ANSI { fddiMAC 71 }"              ::= { fddimibMACEntry 21 }          fddimibMACCopiedCts OBJECT-TYPE              SYNTAX  Counter              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "A count that should as closely as possible match                      the number of frames addressed to (A bit set) and                      successfully copied into the station's receive                      buffers (C bit set) by this MAC (refer to ANSI MAC                      7.5). Note that this count does not include MACCase & Rijsinghani                                             [Page 25]

RFC 1512                        FDDI MIB                  September 1993                      frames."              REFERENCE                      "ANSI { fddiMAC 72 }"              ::= { fddimibMACEntry 22 }          fddimibMACTransmitCts OBJECT-TYPE              SYNTAX  Counter              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "A count that should as closely as possible match                      the number of frames transmitted by this MAC                      (refer to ANSI MAC 7.5).  Note that this count                      does not include MAC frames."              REFERENCE                      "ANSI { fddiMAC 73 }"              ::= { fddimibMACEntry 23 }          fddimibMACErrorCts OBJECT-TYPE              SYNTAX  Counter              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "A count of the number of frames that were                      detected in error by this MAC that had not been                      detected in error by another MAC (refer to ANSI                      MAC 7.5.2)."              REFERENCE                      "ANSI { fddiMAC 81 }"              ::= { fddimibMACEntry 24 }          fddimibMACLostCts OBJECT-TYPE              SYNTAX  Counter              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "A count of the number of instances that this MAC                      detected a format error during frame reception                      such that the frame was stripped (refer to ANSI                      MAC 7.5.3)."              REFERENCE                      "ANSI { fddiMAC 82 }"              ::= { fddimibMACEntry 25 }          fddimibMACFrameErrorThreshold OBJECT-TYPE              SYNTAX  INTEGER (0..65535)              ACCESS  read-write              STATUS  mandatoryCase & Rijsinghani                                             [Page 26]

RFC 1512                        FDDI MIB                  September 1993              DESCRIPTION                      "A threshold for determining when a MAC Condition                      report (see ANSI 8.3.1.1) shall be generated.                      Stations not supporting variable thresholds shall                      have a value of 0 and a range of (0..0)."              REFERENCE                      "ANSI { fddiMAC 95 }"              ::= { fddimibMACEntry 26 }          fddimibMACFrameErrorRatio OBJECT-TYPE              SYNTAX  INTEGER (0..65535)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "This variable is the value of the ratio,                       ((delta fddiMACLostCts + delta fddiMACErrorCts) /                       (delta fddiMACFrameCts + delta fddiMACLostCts ))                       * 2**16 "              REFERENCE                      "ANSI { fddiMAC 96 }"              ::= { fddimibMACEntry 27 }          fddimibMACRMTState OBJECT-TYPE              SYNTAX  INTEGER {                          rm0(1), -- Isolated                          rm1(2), -- Non_Op                          rm2(3), -- Ring_Op                          rm3(4), -- Detect                          rm4(5), -- Non_Op_Dup                          rm5(6), -- Ring_Op_Dup                          rm6(7), -- Directed                          rm7(8)  -- Trace                      }              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "Indicates the current state of the RMT State                      Machine (refer to ANSI 10.3.2)."              REFERENCE                      "ANSI { fddiMAC 111 }"              ::= { fddimibMACEntry 28 }          fddimibMACDaFlag OBJECT-TYPE              SYNTAX  INTEGER { true(1), false(2) }              ACCESS  read-only              STATUS  mandatory              DESCRIPTIONCase & Rijsinghani                                             [Page 27]

RFC 1512                        FDDI MIB                  September 1993                      "The RMT flag Duplicate Address Flag, DA_Flag                      (refer to ANSI 10.2.1.2)."              REFERENCE                      "ANSI { fddiMAC 112 }"              ::= { fddimibMACEntry 29 }          fddimibMACUnaDaFlag OBJECT-TYPE              SYNTAX  INTEGER { true(1), false(2) }              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "A flag, UNDA_Flag (refer to ANSI 8.2.2.1), set                      when the upstream neighbor reports a duplicate                      address condition. Cleared when the condition                      clears."              REFERENCE                      "ANSI { fddiMAC 113 }"              ::= { fddimibMACEntry 30 }          fddimibMACFrameErrorFlag OBJECT-TYPE              SYNTAX  INTEGER { true(1), false(2) }              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "Indicates the MAC Frame Error Condition is                      present when set. Cleared when the condition                      clears and on station initialization."              REFERENCE                      "ANSI { fddiMAC 114 }"              ::= { fddimibMACEntry 31 }          fddimibMACMAUnitdataAvailable OBJECT-TYPE              SYNTAX  INTEGER { true(1), false(2) }              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "This variable shall take on the value of the                      MAC_Avail flag defined in RMT."              REFERENCE                      "ANSI { fddiMAC 116 }"              ::= { fddimibMACEntry 32 }          fddimibMACHardwarePresent OBJECT-TYPE              SYNTAX  INTEGER { true(1), false(2) }              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "This variable indicates the presence ofCase & Rijsinghani                                             [Page 28]

RFC 1512                        FDDI MIB                  September 1993                      underlying hardware support for this MAC object.                      If the value of this object is false(2), the                      reporting of the objects in this entry may be                      handled in an implementation-specific manner."              REFERENCE                      "ANSI { fddiMAC 117 }"              ::= { fddimibMACEntry 33 }          fddimibMACMAUnitdataEnable OBJECT-TYPE              SYNTAX  INTEGER { true(1), false(2) }              ACCESS  read-write              STATUS  mandatory              DESCRIPTION                      "This variable determines the value of the                      MA_UNITDATA_Enable flag in RMT.  The default and                      initial value of this flag is true(1)."              REFERENCE                      "ANSI { fddiMAC 118 }"              ::= { fddimibMACEntry 34 }          -- the Enhanced MAC Counters group          -- Implementation of this Group is optional, but systems          -- claiming support must implement all variables in this          -- group          -- the MAC Counters table          fddimibMACCountersTable OBJECT-TYPE              SYNTAX  SEQUENCE OF FddimibMACCountersEntry              ACCESS  not-accessible              STATUS  mandatory              DESCRIPTION                      "A list of MAC Counters entries.  The number of                      entries shall not exceed the value of                      fddimibMACNumber."              ::= { fddimibMACCounters  1 }          fddimibMACCountersEntry OBJECT-TYPE              SYNTAX  FddimibMACCountersEntry              ACCESS  not-accessible              STATUS  mandatory              DESCRIPTION                      "A MAC Counters entry containing information                      common to a given MAC."              INDEX   { fddimibMACSMTIndex, fddimibMACIndex }              ::= { fddimibMACCountersTable 1 }Case & Rijsinghani                                             [Page 29]

RFC 1512                        FDDI MIB                  September 1993          FddimibMACCountersEntry ::=              SEQUENCE {                  fddimibMACTokenCts                          Counter,                  fddimibMACTvxExpiredCts                          Counter,                  fddimibMACNotCopiedCts                          Counter,                  fddimibMACLateCts                          Counter,                  fddimibMACRingOpCts                          Counter,                  fddimibMACNotCopiedRatio                          INTEGER,                  fddimibMACNotCopiedFlag                          INTEGER,                  fddimibMACNotCopiedThreshold                          INTEGER              }          fddimibMACTokenCts OBJECT-TYPE              SYNTAX  Counter              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "A count that should as closely as possible match                      the number of times the station has received a                      token (total of non-restricted and restricted) on                      this MAC (see ANSI MAC 7.4). This count is                      valuable for determination of network load."              REFERENCE                      "ANSI { fddiMAC 74 }"              ::= { fddimibMACCountersEntry 1 }          fddimibMACTvxExpiredCts OBJECT-TYPE              SYNTAX  Counter              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "A count that should as closely as possible match                      the number of times that TVX has expired."              REFERENCE                      "ANSI { fddiMAC 83 }"              ::= { fddimibMACCountersEntry 2 }          fddimibMACNotCopiedCts OBJECT-TYPE              SYNTAX  Counter              ACCESS  read-onlyCase & Rijsinghani                                             [Page 30]

RFC 1512                        FDDI MIB                  September 1993              STATUS  mandatory              DESCRIPTION                      "A count that should as closely as possible match                      the number of frames that were addressed to this                      MAC but were not copied into its receive buffers                      (see ANSI MAC 7.5). For example, this might occur                      due to local buffer congestion. Because of                      implementation considerations, this count may not                      match the actual number of frames not copied. It                      is not a requirement that this count be exact.                      Note that this count does not include MAC frames."              REFERENCE                      "ANSI { fddiMAC 84 }"              ::= { fddimibMACCountersEntry 3 }          fddimibMACLateCts OBJECT-TYPE              SYNTAX  Counter              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "A count that should as closely as possible match                      the number of TRT expirations since this MAC was                      reset or a token was received (refer to ANSI MAC                      7.4.5)."              REFERENCE                      "ANSI { fddiMAC 85 }"              ::= { fddimibMACCountersEntry 4 }          fddimibMACRingOpCts OBJECT-TYPE              SYNTAX  Counter              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                       "The count of the number of times the ring has                      entered the 'Ring_Operational' state from the                      'Ring Not Operational' state.  This count is                      updated when a SM_MA_STATUS.Indication of a change                      in the Ring_Operational status occurs (refer to                      ANSI 6.1.4). Because of implementation                      considerations, this count may be less than the                      actual RingOp_Ct. It is not a requirement that                      this count be exact."              REFERENCE                      "ANSI { fddiMAC 86 }"              ::= { fddimibMACCountersEntry 5 }          fddimibMACNotCopiedRatio OBJECT-TYPE              SYNTAX  INTEGER (0..65535)Case & Rijsinghani                                             [Page 31]

RFC 1512                        FDDI MIB                  September 1993              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "This variable is the value of the ratio:                       (delta fddiMACNotCopiedCts /                       (delta fddiMACCopiedCts +                         delta fddiMACNotCopiedCts )) * 2**16 "              REFERENCE                      "ANSI { fddiMAC 105 }"              ::= { fddimibMACCountersEntry 6 }          fddimibMACNotCopiedFlag OBJECT-TYPE              SYNTAX  INTEGER { true(1), false(2) }              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "Indicates that the Not Copied condition is                      present when read as true(1).  Set to false(2)                      when the condition clears and on station                      initialization."              REFERENCE                      "ANSI { fddiMAC 115 }"              ::= { fddimibMACCountersEntry 7 }          fddimibMACNotCopiedThreshold OBJECT-TYPE              SYNTAX  INTEGER (0..65535)              ACCESS  read-write              STATUS  mandatory              DESCRIPTION                      "A threshold for determining when a MAC condition                      report shall be generated.  Stations not                      supporting variable thresholds shall have a value                      of 0 and a range of (0..0)."              REFERENCE                      "ANSI { fddiMAC 103 }"              ::= { fddimibMACCountersEntry 8 }          -- the PATH group          -- Implementation of the PATH group is mandatory for all          -- systems which implement manageable FDDI subsystems.          fddimibPATHNumber OBJECT-TYPE              SYNTAX  INTEGER (0..65535)              ACCESS  read-only              STATUS  mandatory              DESCRIPTIONCase & Rijsinghani                                             [Page 32]

RFC 1512                        FDDI MIB                  September 1993                      "The total number of PATHs possible (across all                      SMTs) on this network management application                      entity.  The value for this variable must remain                      constant at least from one re-initialization of                      the entity's network management system to the next                      re-initialization."              ::= { fddimibPATH  1 }          -- the PATH table          fddimibPATHTable OBJECT-TYPE              SYNTAX  SEQUENCE OF FddimibPATHEntry              ACCESS  not-accessible              STATUS  mandatory              DESCRIPTION                      "A list of PATH entries.  The number of entries                      shall not exceed the value of fddimibPATHNumber."              ::= { fddimibPATH  2 }          fddimibPATHEntry OBJECT-TYPE              SYNTAX  FddimibPATHEntry              ACCESS  not-accessible              STATUS  mandatory              DESCRIPTION                      "A PATH entry containing information common to a                      given PATH."              INDEX   { fddimibPATHSMTIndex, fddimibPATHIndex }              ::= { fddimibPATHTable 1 }          FddimibPATHEntry ::=              SEQUENCE {                  fddimibPATHSMTIndex                          INTEGER,                  fddimibPATHIndex                          INTEGER,                  fddimibPATHTVXLowerBound                          FddiTimeNano,                  fddimibPATHTMaxLowerBound                          FddiTimeNano,                  fddimibPATHMaxTReq                          FddiTimeNano              }          fddimibPATHSMTIndex OBJECT-TYPE              SYNTAX  INTEGER (1..65535)              ACCESS  read-only              STATUS  mandatoryCase & Rijsinghani                                             [Page 33]

RFC 1512                        FDDI MIB                  September 1993              DESCRIPTION                      "The value of the SMT index associated with this                      PATH."              ::= { fddimibPATHEntry 1 }          fddimibPATHIndex OBJECT-TYPE              SYNTAX  INTEGER (0..65535)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "Index variable for uniquely identifying the                      primary, secondary and local PATH object                      instances. Local PATH object instances are                      represented with integer values 3 to 255."              REFERENCE                      "ANSI { fddiPATH 11 }"              ::= { fddimibPATHEntry 2 }          fddimibPATHTVXLowerBound OBJECT-TYPE              SYNTAX  FddiTimeNano              ACCESS  read-write              STATUS  mandatory              DESCRIPTION                      "Specifies the minimum time value of                      fddiMACTvxValue that shall be used by any MAC that                      is configured in this path. The operational value                      of fddiMACTvxValue is managed by settting this                      variable.  This variable has the time value range                      of:                      0 < fddimibPATHTVXLowerBound < fddimibPATHMaxTReq                      Changes to this variable shall either satisfy the                      time value relationship:                      fddimibPATHTVXLowerBound <=                      fddimibMACTVXCapability                      of each of the MACs currently on the path, or be                      considered out of range.  The initial value of                      fddimibPATHTVXLowerBound shall be 2500 nsec (2.5                      ms)."              REFERENCE                      "ANSI { fddiPATH 21 }"              ::= { fddimibPATHEntry 3 }          fddimibPATHTMaxLowerBound OBJECT-TYPE              SYNTAX  FddiTimeNanoCase & Rijsinghani                                             [Page 34]

RFC 1512                        FDDI MIB                  September 1993              ACCESS  read-write              STATUS  mandatory              DESCRIPTION                      "Specifies the minimum time value of fddiMACTMax                      that shall be used by any MAC that is configured                      in this path.  The operational value of                      fddiMACTMax is managed by setting this variable.                      This variable has the time value range of:                      fddimibPATHMaxTReq <= fddimibPATHTMaxLowerBound                      and an absolute time value range of:                      10000nsec (10 msec) <= fddimibPATHTMaxLowerBound                      Changes to this variable shall either satisfy the                      time value relationship:                      fddimibPATHTMaxLowerBound <                      fddimibMACTMaxCapability                      of each of the MACs currently on the path, or be                      considered out of range.  The initial value of                      fddimibPATHTMaxLowerBound shall be 165000 nsec                      (165 msec)."              REFERENCE                      "ANSI { fddiPATH 22 }"              ::= { fddimibPATHEntry 4 }          fddimibPATHMaxTReq OBJECT-TYPE              SYNTAX  FddiTimeNano              ACCESS  read-write              STATUS  mandatory              DESCRIPTION                      "Specifies the maximum time value of fddiMACT-Req                      that shall be used by any MAC that is configured                      in this path.  The operational value of fddiMACT-                      Req is managed by setting this variable.  This                      variable has the time value range of:                      fddimibPATHTVXLowerBound < fddimibPATHMaxTReq <=                                               fddimibPATHTMaxLowerBound.                      The default value of fddimibPATHMaxTReq is 165000                      nsec (165 msec)."              REFERENCE                      "ANSI { fddiPATH 23 }"              ::= { fddimibPATHEntry 5 }Case & Rijsinghani                                             [Page 35]

RFC 1512                        FDDI MIB                  September 1993          -- the PATH Configuration table          fddimibPATHConfigTable OBJECT-TYPE              SYNTAX SEQUENCE OF FddimibPATHConfigEntry              ACCESS not-accessible              STATUS mandatory              DESCRIPTION                      "A table of Path configuration entries.  This                      table lists all the resources that may be in this                      Path."              REFERENCE                      "ANSI { fddiPATH 18 }"              ::= { fddimibPATH 3 }          fddimibPATHConfigEntry OBJECT-TYPE              SYNTAX FddimibPATHConfigEntry              ACCESS not-accessible              STATUS mandatory              DESCRIPTION                      "A collection of objects containing information                      for a given PATH Configuration entry."              INDEX { fddimibPATHConfigSMTIndex,                      fddimibPATHConfigPATHIndex,                      fddimibPATHConfigTokenOrder }              ::= { fddimibPATHConfigTable 1 }          FddimibPATHConfigEntry ::=              SEQUENCE {                  fddimibPATHConfigSMTIndex                      INTEGER,                  fddimibPATHConfigPATHIndex                      INTEGER,                  fddimibPATHConfigTokenOrder                      INTEGER,                  fddimibPATHConfigResourceType                      INTEGER,                  fddimibPATHConfigResourceIndex                      INTEGER,                  fddimibPATHConfigCurrentPath                      INTEGER              }          fddimibPATHConfigSMTIndex OBJECT-TYPE              SYNTAX INTEGER (1..65535)              ACCESS read-only              STATUS mandatory              DESCRIPTION                      "The value of the SMT index associated with thisCase & Rijsinghani                                             [Page 36]

RFC 1512                        FDDI MIB                  September 1993                      configuration entry."              ::= { fddimibPATHConfigEntry 1 }          fddimibPATHConfigPATHIndex OBJECT-TYPE              SYNTAX INTEGER (1..65535)              ACCESS read-only              STATUS mandatory              DESCRIPTION                      "The value of the PATH resource index associated                      with this configuration entry."              ::= { fddimibPATHConfigEntry 2 }          fddimibPATHConfigTokenOrder OBJECT-TYPE              SYNTAX INTEGER (1..65535)              ACCESS read-only              STATUS mandatory              DESCRIPTION                      "An object associated with Token order for this                      entry.  Thus if the token passes resources a, b, c                      and d, in that order, then the value of this                      object for these resources would be 1, 2, 3 and 4                      respectively."              ::= { fddimibPATHConfigEntry 3 }          fddimibPATHConfigResourceType OBJECT-TYPE              SYNTAX INTEGER { mac(2), port(4) }              ACCESS read-only              STATUS mandatory              DESCRIPTION                      "The type of resource associated with this                      configuration entry."              ::= { fddimibPATHConfigEntry 4 }          fddimibPATHConfigResourceIndex OBJECT-TYPE              SYNTAX INTEGER (1..65535)              ACCESS read-only              STATUS mandatory              DESCRIPTION                      "The value of the SMT resource index used to refer                      to the instance of this MAC or Port resource."              ::= { fddimibPATHConfigEntry 5 }          fddimibPATHConfigCurrentPath OBJECT-TYPE              SYNTAX INTEGER {                       isolated(1), local(2), secondary(3), primary(4),                       concatenated(5), thru(6)                     }              ACCESS read-onlyCase & Rijsinghani                                             [Page 37]

RFC 1512                        FDDI MIB                  September 1993              STATUS mandatory              DESCRIPTION                      "The current insertion status for this resource on                      this Path."              ::= { fddimibPATHConfigEntry 6 }          -- the PORT group          -- Implementation of the PORT group is mandatory for all          -- systems which implement manageable FDDI subsystems.          fddimibPORTNumber OBJECT-TYPE              SYNTAX  INTEGER (0..65535)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The total number of PORT implementations (across                      all SMTs) on this network management application                      entity.  The value for this variable must remain                      constant at least from one re-initialization of                      the entity's network management system to the next                      re-initialization."              ::= { fddimibPORT  1 }          -- the PORT table          fddimibPORTTable OBJECT-TYPE              SYNTAX  SEQUENCE OF FddimibPORTEntry              ACCESS  not-accessible              STATUS  mandatory              DESCRIPTION                      "A list of PORT entries.  The number of entries                      shall not exceed the value of fddimibPORTNumber."              ::= { fddimibPORT  2 }          fddimibPORTEntry OBJECT-TYPE              SYNTAX  FddimibPORTEntry              ACCESS  not-accessible              STATUS  mandatory              DESCRIPTION                      "A PORT entry containing information common to a                      given PORT."              INDEX   { fddimibPORTSMTIndex, fddimibPORTIndex }              ::= { fddimibPORTTable 1 }          FddimibPORTEntry ::=              SEQUENCE {Case & Rijsinghani                                             [Page 38]

RFC 1512                        FDDI MIB                  September 1993                  fddimibPORTSMTIndex                          INTEGER,                  fddimibPORTIndex                          INTEGER,                  fddimibPORTMyType                          INTEGER,                  fddimibPORTNeighborType                          INTEGER,                  fddimibPORTConnectionPolicies                          INTEGER,                  fddimibPORTMACIndicated                          INTEGER,                  fddimibPORTCurrentPath                          INTEGER,                  fddimibPORTRequestedPaths                          OCTET STRING,                  fddimibPORTMACPlacement                          FddiResourceId,                  fddimibPORTAvailablePaths                          INTEGER,                  fddimibPORTPMDClass                          INTEGER,                  fddimibPORTConnectionCapabilities                          INTEGER,                  fddimibPORTBSFlag                          INTEGER,                  fddimibPORTLCTFailCts                          Counter,                  fddimibPORTLerEstimate                          INTEGER,                  fddimibPORTLemRejectCts                          Counter,                  fddimibPORTLemCts                          Counter,                  fddimibPORTLerCutoff                          INTEGER,                  fddimibPORTLerAlarm                          INTEGER,                  fddimibPORTConnectState                          INTEGER,                  fddimibPORTPCMState                          INTEGER,                  fddimibPORTPCWithhold                          INTEGER,                  fddimibPORTLerFlag                          INTEGER,                  fddimibPORTHardwarePresent                          INTEGER,Case & Rijsinghani                                             [Page 39]

RFC 1512                        FDDI MIB                  September 1993                  fddimibPORTAction                          INTEGER              }          fddimibPORTSMTIndex OBJECT-TYPE              SYNTAX  INTEGER (1..65535)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The value of the SMT index associated with this                      PORT."              ::= { fddimibPORTEntry 1 }          fddimibPORTIndex OBJECT-TYPE              SYNTAX  INTEGER (1..65535)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "A unique value for each PORT within a given SMT,                      which is the same as the corresponding resource                      index in SMT.  The value for each PORT must remain                      constant at least from one re-initialization of                      the entity's network management system to the next                      re-initialization."              REFERENCE                      "ANSI { fddiPORT 29 }"              ::= { fddimibPORTEntry 2 }          fddimibPORTMyType OBJECT-TYPE              SYNTAX  INTEGER { a(1), b(2), s(3), m(4), none(5) }              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The value of the PORT's PC_Type (refer to ANSI                      9.4.1, and 9.6.3.2)."              REFERENCE                      "ANSI { fddiPORT 12 }"              ::= { fddimibPORTEntry 3 }          fddimibPORTNeighborType OBJECT-TYPE              SYNTAX  INTEGER { a(1), b(2), s(3), m(4), none(5) }              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The type of the remote PORT as determined in PCM.                      This variable has an initial value of none, and is                      only modified in PC_RCode(3)_Actions (refer to                      ANSI SMT 9.6.3.2)."Case & Rijsinghani                                             [Page 40]

RFC 1512                        FDDI MIB                  September 1993              REFERENCE                      "ANSI { fddiPORT 13 }"              ::= { fddimibPORTEntry 4 }          fddimibPORTConnectionPolicies OBJECT-TYPE              SYNTAX  INTEGER (0..3)              ACCESS  read-write              STATUS  mandatory              DESCRIPTION                      "A value representing the PORT's connection                      policies desired in the node. The value of pc-                      mac-lct is a term used in the PC_MAC_LCT Flag (see                      9.4.3.2).  The value of pc-mac-loop is a term used                      in the PC_MAC_Loop Flag.                      The value is a sum.  This value initially takes                      the value zero, then for each PORT policy, 2                      raised to a power is added to the sum.  The powers                      are according to the following table:                                    Policy   Power                                pc-mac-lct     0                               pc-mac-loop     1 "              REFERENCE                      "ANSI { fddiPORT 14 }"              ::= { fddimibPORTEntry 5 }          fddimibPORTMACIndicated OBJECT-TYPE              SYNTAX  INTEGER {                          tVal9FalseRVal9False(1),                          tVal9FalseRVal9True(2),                          tVal9TrueRVal9False(3),                          tVal9TrueRVal9True(4)                      }              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The indications (T_Val(9), R_Val(9)) in PC-                      Signalling, of the intent to place a MAC in the                      output token path to a PORT (refer to ANSI SMT                      9.6.3.2.)."              REFERENCE                      "ANSI { fddiPORT 15 }"              ::= { fddimibPORTEntry 6 }          fddimibPORTCurrentPath OBJECT-TYPE              SYNTAX  INTEGER {                          ce0(1), -- isolatedCase & Rijsinghani                                             [Page 41]

RFC 1512                        FDDI MIB                  September 1993                          ce1(2), -- local                          ce2(3), -- secondary                          ce3(4), -- primary                          ce4(5), -- concatenated                          ce5(6)  -- thru                      }              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "Indicates the Path(s) into which this PORT is                      currently inserted."              REFERENCE                      "ANSI { fddiPORT 16 }"              ::= { fddimibPORTEntry 7 }          fddimibPORTRequestedPaths OBJECT-TYPE              SYNTAX  OCTET STRING (SIZE (3))              ACCESS  read-write              STATUS  mandatory              DESCRIPTION                      "This variable is a list of permitted Paths where                      each list element defines the Port's permitted                      Paths.  The first octet corresponds to 'none', the                      second octet to 'tree', and the third octet to                      'peer'."              REFERENCE                      "ANSI { fddiPORT 17 }"              ::= { fddimibPORTEntry 8 }          fddimibPORTMACPlacement OBJECT-TYPE              SYNTAX  FddiResourceId -- INTEGER (0..65535)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "Indicates the MAC, if any, whose transmit path                      exits the station via this PORT. The value shall                      be zero if there is no MAC associated with the                      PORT. Otherwise, the MACIndex of the MAC will be                      the value of the variable."              REFERENCE                      "ANSI { fddiPORT 18 }"              ::= { fddimibPORTEntry 9 }          fddimibPORTAvailablePaths OBJECT-TYPE              SYNTAX  INTEGER (0..7)              ACCESS  read-only              STATUS  mandatory              DESCRIPTIONCase & Rijsinghani                                             [Page 42]

RFC 1512                        FDDI MIB                  September 1993                      "Indicates the Paths which are available to this                      Port. In the absence of faults, the A and B Ports                      will always have both the Primary and Secondary                      Paths available.                      The value is a sum.  This value initially takes                      the value zero, then for each type of PATH that                      this port has available, 2 raised to a power is                      added to the sum.  The powers are according to the                      following table:                               Path   Power                            Primary     0                          Secondary     1                              Local     2 "              REFERENCE                      "ANSI { fddiPORT 19 }"              ::= { fddimibPORTEntry 10 }          fddimibPORTPMDClass OBJECT-TYPE              SYNTAX  INTEGER {                              multimode(1),                              single-mode1(2),                              single-mode2(3),                              sonet(4),                              low-cost-fiber(5),                              twisted-pair(6),                              unknown(7),                              unspecified(8)                      }              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "This variable indicates the type of PMD entity                      associated with this port."              REFERENCE                      "ANSI { fddiPORT 22 }"              ::= { fddimibPORTEntry 11 }          fddimibPORTConnectionCapabilities OBJECT-TYPE              SYNTAX  INTEGER (0..3)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "A value that indicates the connection                      capabilities of the port. The pc-mac-lct bit                      indicates that the station has the capability of                      setting the PC_MAC_LCT Flag. The pc-mac-loop bitCase & Rijsinghani                                             [Page 43]

RFC 1512                        FDDI MIB                  September 1993                      indicates that the station has the capability of                      setting the PC_MAC_Loop Flag (refer to ANSI                      9.4.3.2).                      The value is a sum.  This value initially takes                      the value zero, then for each capability that this                      port has, 2 raised to a power is added to the sum.                      The powers are according to the following table:                         capability   Power                         pc-mac-lct     0                        pc-mac-loop     1 "              REFERENCE                      "ANSI { fddiPORT 23 }"              ::= { fddimibPORTEntry 12 }          fddimibPORTBSFlag OBJECT-TYPE              SYNTAX  INTEGER { true(1), false(2) }              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "This variable assumes the value of the BS_Flag                      (refer to ANSI SMT 9.4.3.3)."              REFERENCE                      "ANSI { fddiPORT 33 }"              ::= { fddimibPORTEntry 13 }          fddimibPORTLCTFailCts OBJECT-TYPE              SYNTAX  Counter              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The count of the consecutive times the link                      confidence test (LCT) has failed during connection                      management (refer to ANSI 9.4.1)."              REFERENCE                      "ANSI { fddiPORT 42 }"              ::= { fddimibPORTEntry 14 }          fddimibPORTLerEstimate OBJECT-TYPE              SYNTAX  INTEGER (4..15)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "A long term average link error rate. It ranges                      from 10**-4 to 10**-15 and is reported as the                      absolute value of the base 10 logarithm (refer to                      ANSI SMT 9.4.7.5.)."Case & Rijsinghani                                             [Page 44]

RFC 1512                        FDDI MIB                  September 1993              REFERENCE                      "ANSI { fddiPORT 51 }"              ::= { fddimibPORTEntry 15 }          fddimibPORTLemRejectCts OBJECT-TYPE              SYNTAX  Counter              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "A link error monitoring count of the times that a                      link has been rejected."              REFERENCE                      "ANSI { fddiPORT 52 }"              ::= { fddimibPORTEntry 16 }          fddimibPORTLemCts OBJECT-TYPE              SYNTAX  Counter              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The aggregate link error monitor error count, set                      to zero only on station initialization."              REFERENCE                      "ANSI { fddiPORT 53 }"              ::= { fddimibPORTEntry 17 }          fddimibPORTLerCutoff OBJECT-TYPE              SYNTAX  INTEGER (4..15)              ACCESS  read-write              STATUS  mandatory              DESCRIPTION                       "The link error rate estimate at which a link                      connection will be broken. It ranges from 10**-4                      to 10**-15 and is reported as the absolute value                      of the base 10 logarithm (default of 7)."              REFERENCE                      "ANSI { fddiPORT 58 }"              ::= { fddimibPORTEntry 18 }          fddimibPORTLerAlarm OBJECT-TYPE              SYNTAX  INTEGER (4..15)              ACCESS  read-write              STATUS  mandatory              DESCRIPTION                      "The link error rate estimate at which a link                      connection will generate an alarm. It ranges from                      10**-4 to 10**-15 and is reported as the absolute                      value of the base 10 logarithm of the estimateCase & Rijsinghani                                             [Page 45]

RFC 1512                        FDDI MIB                  September 1993                      (default of 8)."              REFERENCE                      "ANSI { fddiPORT 59 }"              ::= { fddimibPORTEntry 19 }          fddimibPORTConnectState OBJECT-TYPE              SYNTAX  INTEGER {                          disabled(1),                          connecting(2),                          standby(3),                          active(4)                      }              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "An indication of the connect state of this PORT                      and is equal to the value of Connect_State (refer                      to ANSI 9.4.1)"              REFERENCE                      "ANSI { fddiPORT 61 }"              ::= { fddimibPORTEntry 20 }          fddimibPORTPCMState OBJECT-TYPE              SYNTAX  INTEGER {                          pc0(1), -- Off                          pc1(2), -- Break                          pc2(3), -- Trace                          pc3(4), -- Connect                          pc4(5), -- Next                          pc5(6), -- Signal                          pc6(7), -- Join                          pc7(8), -- Verify                          pc8(9), -- Active                          pc9(10) -- Maint                      }              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The state of this Port's PCM state machine refer                      to ANSI SMT 9.6.2)."              REFERENCE                      "ANSI { fddiPORT 62 }"              ::= { fddimibPORTEntry 21 }          fddimibPORTPCWithhold OBJECT-TYPE              SYNTAX  INTEGER {                           none(1),                           m-m(2),Case & Rijsinghani                                             [Page 46]

RFC 1512                        FDDI MIB                  September 1993                           otherincompatible(3),                           pathnotavailable(4)                      }              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The value of PC_Withhold (refer to ANSI SMT                      9.4.1)."              REFERENCE                      "ANSI { fddiPORT 63 }"              ::= { fddimibPORTEntry 22 }          fddimibPORTLerFlag OBJECT-TYPE              SYNTAX  INTEGER { true(1), false(2) }              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The condition becomes active when the value of                      fddiPORTLerEstimate is less than or equal to                      fddiPORTLerAlarm. This will be reported with the                      Status Report Frames (SRF) (refer to ANSI SMT                       7.2.7 and 8.3)."              REFERENCE                      "ANSI { fddiPORT 64 }"              ::= { fddimibPORTEntry 23 }          fddimibPORTHardwarePresent OBJECT-TYPE              SYNTAX  INTEGER { true(1), false(2) }              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "This variable indicates the presence of                      underlying hardware support for this Port object.                      If the value of this object is false(2), the                      reporting of the objects in this entry may be                      handled in an implementation-specific manner."              REFERENCE                      "ANSI { fddiPORT 65 }"              ::= { fddimibPORTEntry 24 }          fddimibPORTAction OBJECT-TYPE              SYNTAX  INTEGER {                      other(1),           -- none of the following                      maintPORT(2),                      enablePORT(3),                      disablePORT(4),                      startPORT(5),                      stopPORT(6)Case & Rijsinghani                                             [Page 47]

RFC 1512                        FDDI MIB                  September 1993                      }              ACCESS  read-write              STATUS  mandatory              DESCRIPTION                      "Causes a Control signal to be generated with a                      control_action of 'Signal' and the 'variable'                      parameter set with the appropriate value (i.e.,                      PC_Maint, PC_Enable, PC_Disable, PC_Start, or                      PC_Stop) (refer to ANSI 9.4.2)."              REFERENCE                      "ANSI { fddiPORT 70 }"              ::= { fddimibPORTEntry 25 }          END5.  Acknowledgements   This document was produced by the IETF FDDI MIB working group:               Hossein Alaee, 3Com Corporation               Haggar Alsaleh, Bell Northern Research               William Anderson, Mitre Corporation               Alan Apt, Addison-Wesley               Mary Artibee, Silicon Graphics               Karen Auerbach, Epilogue Technologies               Doug Bagnall, Apollo/Hewlett Packard               Chet Birger, Coral Network Corporation               Pablo Brenner, Fibronics               Howard Brown, Cabletron               Jack Brown, US Army Computer Engineering Center               Eric Brunner               Jeff Case, The University of Tennessee               Tammy Chan, Fibercom               Asheem Chandna, AT&T               Cho Y. Chang, Apollo/Hewlett Packard               Chris Chiotasso, Fibronics               Paul Ciarfella, Digital Equipment Corporation               John Cook, Chipcom               Don Coolidge, Silicon Graphics               Burt Cyr, Unisys               James R. Davin, Massachusetts Institute of Technology               Nabil Damouny               Nadya El-Afandi, Network Systems Corporation               Hunaid Engineer, Cray Research               Jeff Fitzgerald, Fibercom               Richard Fox, Synoptics               Stan Froyd, ACCCase & Rijsinghani                                             [Page 48]

RFC 1512                        FDDI MIB                  September 1993               Debbie Futcher, U.S. Naval Surface Warfare Center               Joseph Golio, Cray Research               Jeremy Greene, Coral               Peter Hayden, Digital Equipment Corporation               Scott Hiles, U.S. Naval Surface Warfare Center               Greg Jones, Data General               Satish Joshi, SynOptics Communications               Jayant Kadambi, AT&T Bell Labs               Joanna Karwowska, Data General               Frank Kastenholz, Interlan               Jim Kinder, Fibercom               Christopher Kolb, PSI               Cheryl Krupczak, NCR               Peter Lin, Vitalink               Then Liu               John R. LoVerso, Concurrent Computer Corporation               Ron Mackey, Distributed Systems International, Inc.               Gary Malkin, Proteon               Bruce McClure, Synernetics               Keith McCloghrie, Hughes Lan Systems               Donna McMaster, SynOptics               John O'Hara, Massachusetts Institute of Technology               Luc Pariseau, Digital Equipment Corporation               Dave Perkins, SynOptics Communications               James E. Reeves, SynOptics Communications               Jim Reinstedler, Ungermann-Bass               Radhi Renous, Fibronics               Sal Ricci, AT&T/NCR               Anil Rijsinghani, Digital Equipment Corporation               Bob Rolla, Synernetics               Nelson Ronkin, Synernetics               Marshall T. Rose, Performance Systems International, Inc.               Milt Roselinsky, CMC               Jon Saperia, Digital Equipment Corporation               Greg Satz, cisco Systems               Steven Senum, Network Systems Corporation               Jim Sheridan, IBM Corporation               Jeffrey Schiller, MIT               Dror Shindelman, Fibronics               Mark Sleeper, Sparta               Lou Steinberg, IBM Corporation               Larry Stefani, Digital Equipment Corporation               Mary Jane Strohl, Apollo/Hewlett Packard               Sally Tarquinio, Mitre Corporation               Kaj Tesink, Bellcore               Ian Thomas, Chipcom               Dean Throop, Data General               Bill Townsend, XylogicsCase & Rijsinghani                                             [Page 49]

RFC 1512                        FDDI MIB                  September 1993               Ahmet H. Tuncay, SynOptics Communications               Mike Turico, Motorola               Chris VandenBerg, ACC               Sudhanshu Verma, Hewlett Packard               Joe Vermeulen, UNISYS               David Waiteman, BBN               Bert Williams, Synernetics               Mark Wood, Distributed Systems International, Inc.               Y. C. Yang               Denis Yaro, Sun Microsystems               Jeff Young, Cray Research   The author gratefully acknowledges the labors of Judi Talley and   David Reid of SNMP Research, Inc. for their editorial assistance in   the preparation of this document.6.  References   [1]  Rose M., and K. McCloghrie, "Structure and Identification of        Management Information for TCP/IP-based internets", STD 16,RFC1155, Performance Systems International, Hughes LAN Systems, May        1990.   [2]  Case, J., "FDDI Management Information Base",RFC 1285, SNMP        Research, Incorporated, January 1992.   [3]  Case, J., Fedor, M., Schoffstall, M., and J. Davin, "Simple        Network Management Protocol", STD 15,RFC 1157, SNMP Research,        Performance Systems International, Performance Systems        International, MIT Laboratory for Computer Science, May 1990.   [4]  McCloghrie K., and M. Rose, Editors, "Management Information        Base for Network Management of TCP/IP-based internets", STD 17,RFC 1213, Performance Systems International, March 1991.   [5]  Information processing systems - Open Systems Interconnection -        Specification of Abstract Syntax Notation One (ASN.1),        International Organization for Standardization.  International        Standard 8824, (December, 1987).   [6]  Information processing systems - Open Systems Interconnection -        Specification of Basic Encoding Rules for Abstract Notation One        (ASN.1), International Organization for Standardization.        International Standard 8825, (December, 1987).   [7]  Rose, M., and K. McCloghrie, Editors, "Concise MIB Definitions",        STD 16,RFC 1212, Performance Systems International, Hughes LAN        Systems, March 1991.Case & Rijsinghani                                             [Page 50]

RFC 1512                        FDDI MIB                  September 1993   [8]  American National Standards Institute, FDDI Station Management        (SMT), Draft Proposed American National Standard, American        National Standards Institute, X3T9.5/84-49 REV 7.3.7. Security Considerations   Security issues are not discussed in this memo.8. Authors' Addresses   Jeffrey D. Case   The University of Tennessee   Department of Computer Science   107 Ayres Hall   Knoxville, Tennessee  37996   and   SNMP Research, Incorporated   3001 Kimberlin Heights Road   Knoxville, Tennessee  37920   Phone: (615) 974-5067 or (615) 573-1434   EMail: case@CS.UTK.EDU   Anil Rijsinghani   Digital Equipment Corporation   295 Foster Street   Littleton, MA 01460-1123   Phone: (508) 952-3520   EMail: anil@levers.enet.dec.comCase & Rijsinghani                                             [Page 51]

[8]ページ先頭

©2009-2025 Movatter.jp