Network Working Group                                 B. Stewart, EditorRequest for Comments: 1317                                  Xyplex, Inc.                                                              April 1992Definitions of Managed Objects forRS-232-like Hardware DevicesStatus of this Memo   This document specifies an IAB standards track protocol for the   Internet community, and requests discussion and suggestions for   improvements.  Please refer to the current edition of the "IAB   Official Protocol Standards" for the standardization state and status   of this protocol.  Distribution of this memo is unlimited.1.  Abstract   This memo defines a portion of the Management Information Base (MIB)   for use with network management protocols in TCP/IP based internets.   In particular, it defines objects for the management of RS-232-like   devices.2.  The Network Management Framework   The Internet-standard Network Management Framework consists of three   components.  They are:RFC 1155 which defines the SMI, the mechanisms used for describing   and naming objects for the purpose of management.RFC 1212 defines a   more concise description mechanism, which is wholly consistent with   the SMI.RFC 1156 which defines MIB-I, the core set of managed objects for the   Internet suite of protocols.RFC 1213, defines MIB-II, an evolution   of MIB-I based on implementation experience and new operational   requirements.RFC 1157 which defines the SNMP, the protocol used for network access   to managed objects.   The Framework permits new objects to be defined for the purpose of   experimentation and evaluation.3.  Objects   Managed objects are accessed via a virtual information store, termed   the Management Information Base or MIB. Objects in the MIB areCharacter MIB Working Group                                     [Page 1]

RFC 1317                    RS-232-LIKE MIB                   April 1992   defined using the subset of Abstract Syntax Notation One (ASN.1) [7]   defined in the SMI.  In particular, each object has a name, a syntax,   and an encoding.  The name is an object identifier, an   administratively assigned name, which specifies an object type.   The object type together with an object instance serves to uniquely   identify a specific instantiation of the object. For human   convenience, we often use a textual string, termed the OBJECT   DESCRIPTOR, to also refer to the object type.   The syntax of an object type defines the abstract data structure   corresponding to that object type.  The ASN.1 language is used for   this purpose.  However, the SMI [3] purposely restricts the ASN.1   constructs which may be used. These restrictions are explicitly made   for simplicity.   The encoding of an object type is simply how that object type is   represented using the object type's syntax. Implicitly tied to the   notion of an object type's syntax and encoding is how the object type   is represented when being transmitted on the network.   The SMI specifies the use of the basic encoding rules of ASN.1 [8],   subject to the additional requirements imposed by the SNMP.3.1.  Format of DefinitionsSection 5 contains the specification of all object types contained in   this MIB module.  The object types are defined using the conventions   defined in the SMI, as amended by the extensions specified in [9,10].4.  Overview   The RS-232-like Hardware Device MIB applies to interface ports that   might logically support the Interface MIB, a Transmission MIB, or the   Character MIB.  The most common example is an RS-232 port with modem   signals.   The RS-232-like MIB is one of a set of MIBs designed for   complementary use.  At this writing, the set comprises:        Character MIB        PPP MIB        RS-232-like MIB        Parallel-printer-like MIB   The RS-232-like MIB and the Parallel-printer-like MIB represent the   physical layer, providing service to higher layers such as the   Character MIB or PPP MIB.  Further MIBs may appear above these.Character MIB Working Group                                     [Page 2]

RFC 1317                    RS-232-LIKE MIB                   April 1992   The following diagram shows two possible "MIB stacks", each using the   RS-232-like MIB.                                   .-----------------.        .-----------------.        |  Standard MIB   |        |   Telnet MIB    |        | Interface Group |        |-----------------|        |-----------------|        |  Character MIB  |        |     PPP MIB     |        |-----------------|        |-----------------|        | RS-232-like MIB |        | RS-232-like MIB |        `-----------------'        `-----------------'   The intent of the model is for the physical-level MIBs to represent   the lowest level, regardless of the higher level that may be using   it.  In turn, separate higher level MIBs represent specific   applications, such as a terminal (the Character MIB) or a network   connection (the PPP MIB).   The RS-232-like Hardware Device MIB is mandatory for all systems that   have such a hardware port supporting services managed through some   other MIB, for example, the Character MIB or PPP MIB.   The MIB includes multiple similar types of hardware, and as a result   contains objects not applicable to all of those types.  Such objects   are in a separate branch of the MIB, which is required when   applicable and otherwise absent.   The RS-232-like Hardware Port MIB includes RS-232, RS-422, RS-423,   V.35, and other asynchronous or synchronous, serial physical links   with a similar set of control signals.   The MIB contains objects that relate to physical layer connections.   Such connections may provide interesting hardware signals (other than   for basic data transfer), such as RNG and DCD.  Hardware ports also   have such attributes as speed and bits per character.   Usefulness of error counters in this MIB depends on the presence of   non-error character counts in higher level MIBs.   The MIB comprises one base object and four tables, detailed in the   following sections.  The tables contain objects for all ports,   asynchronous ports, and input and output control signals.Character MIB Working Group                                     [Page 3]

RFC 1317                    RS-232-LIKE MIB                   April 19925.  DefinitionsRFC1317-MIB DEFINITIONS ::= BEGIN                    IMPORTS                       Counter                               FROMRFC1155-SMI                       transmission                               FROMRFC1213-MIB                       OBJECT-TYPE                               FROMRFC-1212;       -- this is the MIB module for RS-232-like hardware devices       rs232    OBJECT IDENTIFIER ::= { transmission 33 }       -- the generic RS-232-like group       -- Implementation of this group is mandatory for all       -- systems that have RS-232-like hardware ports       -- supporting higher level services such as character       -- streams or network interfaces       rs232Number OBJECT-TYPE           SYNTAX INTEGER           ACCESS read-only           STATUS mandatory           DESCRIPTION               "The number of ports (regardless of their current               state) in the RS-232-like general port table."           ::= { rs232 1 }       -- the RS-232-like general Port table       rs232PortTable OBJECT-TYPE           SYNTAX SEQUENCE OF Rs232PortEntry           ACCESS not-accessible           STATUS mandatory           DESCRIPTION               "A list of port entries.  The number of entries is               given by the value of rs232Number."           ::= { rs232 2 }       rs232PortEntry OBJECT-TYPE           SYNTAX Rs232PortEntry           ACCESS not-accessibleCharacter MIB Working Group                                     [Page 4]

RFC 1317                    RS-232-LIKE MIB                   April 1992           STATUS mandatory           DESCRIPTION               "Status and parameter values for a port."           INDEX { rs232PortIndex }           ::= { rs232PortTable 1 }       Rs232PortEntry ::=           SEQUENCE {               rs232PortIndex                   INTEGER,               rs232PortType                   INTEGER,               rs232PortInSigNumber                   INTEGER,               rs232PortOutSigNumber                   INTEGER,               rs232PortInSpeed                   INTEGER,               rs232PortOutSpeed                   INTEGER    }       rs232PortIndex OBJECT-TYPE           SYNTAX INTEGER           ACCESS read-only           STATUS mandatory           DESCRIPTION               "A unique value for each port.  Its value ranges               between 1 and the value of rs232Number.  By               convention and if possible, hardware port numbers               map directly to external connectors.  The value for               each port must remain constant at least from one               re-initialization of the network management agent to               the next."           ::= { rs232PortEntry 1 }       rs232PortType OBJECT-TYPE           SYNTAX INTEGER { other(1), rs232(2), rs422(3),                            rs423(4), v35(5) }           ACCESS read-only           STATUS mandatory           DESCRIPTION               "The port's hardware type."           ::= { rs232PortEntry 2 }       rs232PortInSigNumber OBJECT-TYPE           SYNTAX INTEGER           ACCESS read-only           STATUS mandatoryCharacter MIB Working Group                                     [Page 5]

RFC 1317                    RS-232-LIKE MIB                   April 1992           DESCRIPTION               "The number of input signals for the port in the               input signal table (rs232PortInSigTable).  The table               contains entries only for those signals the software               can detect."           ::= { rs232PortEntry 3 }       rs232PortOutSigNumber OBJECT-TYPE           SYNTAX INTEGER           ACCESS read-only           STATUS mandatory           DESCRIPTION               "The number of output signals for the port in the               output signal table (rs232PortOutSigTable).  The               table contains entries only for those signals the               software can assert."           ::= { rs232PortEntry 4 }       rs232PortInSpeed OBJECT-TYPE           SYNTAX INTEGER           ACCESS read-write           STATUS mandatory           DESCRIPTION               "The port's input speed in bits per second."           ::= { rs232PortEntry 5 }       rs232PortOutSpeed OBJECT-TYPE           SYNTAX INTEGER           ACCESS read-write           STATUS mandatory           DESCRIPTION               "The port's output speed in bits per second."           ::= { rs232PortEntry 6 }       -- the RS-232-like Asynchronous Port group       -- Implementation of this group is mandatory if the system       -- has any asynchronous ports.  Otherwise it is not       -- present.       rs232AsyncPortTable OBJECT-TYPE           SYNTAX SEQUENCE OF Rs232AsyncPortEntry           ACCESS not-accessible           STATUS mandatory           DESCRIPTION               "A list of asynchronous port entries.  The maximum               entry number is given by the value of rs232Number.Character MIB Working Group                                     [Page 6]

RFC 1317                    RS-232-LIKE MIB                   April 1992               Entries need not exist for synchronous ports."           ::= { rs232 3 }       rs232AsyncPortEntry OBJECT-TYPE           SYNTAX Rs232AsyncPortEntry           ACCESS not-accessible           STATUS mandatory           DESCRIPTION               "Status and parameter values for an asynchronous               port."           INDEX { rs232AsyncPortIndex }           ::= { rs232AsyncPortTable 1 }       Rs232AsyncPortEntry ::=           SEQUENCE {               rs232AsyncPortIndex                   INTEGER,               rs232AsyncPortBits                   INTEGER,               rs232AsyncPortStopBits                   INTEGER,               rs232AsyncPortParity                   INTEGER,               rs232AsyncPortAutobaud                   INTEGER,               rs232AsyncPortParityErrs                   Counter,               rs232AsyncPortFramingErrs                   Counter,               rs232AsyncPortOverrunErrs                   Counter           }       rs232AsyncPortIndex OBJECT-TYPE           SYNTAX INTEGER           ACCESS read-only           STATUS mandatory           DESCRIPTION               "A unique value for each port.  Its value is the               same as rs232PortIndex for the port."           ::= { rs232AsyncPortEntry 1 }       rs232AsyncPortBits OBJECT-TYPE           SYNTAX INTEGER (5..8)           ACCESS read-write           STATUS mandatory           DESCRIPTIONCharacter MIB Working Group                                     [Page 7]

RFC 1317                    RS-232-LIKE MIB                   April 1992               "The port's number of bits in a character."           ::= { rs232AsyncPortEntry 2 }       rs232AsyncPortStopBits OBJECT-TYPE           SYNTAX INTEGER { one(1), two(2),                            one-and-half(3), dynamic(4) }           ACCESS read-write           STATUS mandatory           DESCRIPTION               "The port's number of stop bits."           ::= { rs232AsyncPortEntry 3 }       rs232AsyncPortParity OBJECT-TYPE           SYNTAX INTEGER { none(1), odd(2), even(3),                            mark(4), space(5) }           ACCESS read-write           STATUS mandatory           DESCRIPTION               "The port's sense of a character parity bit."           ::= { rs232AsyncPortEntry 4 }       rs232AsyncPortAutobaud OBJECT-TYPE           SYNTAX INTEGER { enabled(1), disabled(2) }           ACCESS read-write           STATUS mandatory           DESCRIPTION               "A control for the port's ability to automatically               sense input speed.               When rs232PortAutoBaud is 'enabled', a port may               autobaud to values different from the set values for               speed, parity, and character size.  As a result a               network management system may temporarily observe               values different from what was previously set."           ::= { rs232AsyncPortEntry 5 }       rs232AsyncPortParityErrs OBJECT-TYPE           SYNTAX Counter           ACCESS read-only           STATUS mandatory           DESCRIPTION               "Total number of characters with a parity error,               input from the port since system re-initialization               and while the port state was 'up' or 'test'."           ::= { rs232AsyncPortEntry 6 }       rs232AsyncPortFramingErrs OBJECT-TYPE           SYNTAX CounterCharacter MIB Working Group                                     [Page 8]

RFC 1317                    RS-232-LIKE MIB                   April 1992           ACCESS read-only           STATUS mandatory           DESCRIPTION               "Total number of characters with a framing error,               input from the port since system re-initialization               and while the port state was 'up' or 'test'."           ::= { rs232AsyncPortEntry 7 }       rs232AsyncPortOverrunErrs OBJECT-TYPE           SYNTAX Counter           ACCESS read-only           STATUS mandatory           DESCRIPTION               "Total number of characters with an overrun error,               input from the port since system re-initialization               and while the port state was 'up' or 'test'."           ::= { rs232AsyncPortEntry 8 }       -- the RS-232-like Synchronous Port group       -- Implementation of this group is mandatory if the system       -- has any synchronous ports.  Otherwise it is not       -- present.       rs232SyncPortTable OBJECT-TYPE           SYNTAX SEQUENCE OF Rs232SyncPortEntry           ACCESS not-accessible           STATUS mandatory           DESCRIPTION               "A list of synchronous port entries.  The maximum               entry number is given by the value of rs232Number.               Entries need not exist for asynchronous ports."           ::= { rs232 4 }       rs232SyncPortEntry OBJECT-TYPE           SYNTAX Rs232SyncPortEntry           ACCESS not-accessible           STATUS mandatory           DESCRIPTION               "Status and parameter values for a synchronous               port."           INDEX { rs232SyncPortIndex }           ::= { rs232SyncPortTable 1 }       Rs232SyncPortEntry ::=           SEQUENCE {               rs232SyncPortIndexCharacter MIB Working Group                                     [Page 9]

RFC 1317                    RS-232-LIKE MIB                   April 1992                   INTEGER,               rs232SyncPortClockSource                   INTEGER,               rs232SyncPortFrameCheckErrs                   Counter,               rs232SyncPortTransmitUnderrunErrs                   Counter,               rs232SyncPortReceiveOverrunErrs                   Counter,               rs232SyncPortInterruptedFrames                   Counter,               rs232SyncPortAbortedFrames                   Counter           }       rs232SyncPortIndex OBJECT-TYPE           SYNTAX INTEGER           ACCESS read-only           STATUS mandatory           DESCRIPTION               "A unique value for each port.  Its value is the               same as rs232PortIndex for the port."           ::= { rs232SyncPortEntry 1 }       rs232SyncPortClockSource OBJECT-TYPE           SYNTAX INTEGER  { internal(1), external(2), split(3) }           ACCESS read-write           STATUS mandatory           DESCRIPTION               "Source of the port's bit rate clock. 'split' means               the tranmit clock is internal and the receive clock               is external."           ::= { rs232SyncPortEntry 2 }       rs232SyncPortFrameCheckErrs OBJECT-TYPE           SYNTAX Counter           ACCESS read-only           STATUS mandatory           DESCRIPTION               "Total number of frames with an invalid frame check               sequence, input from the port since system               re-initialization and while the port state was 'up'               or 'test'."           ::= { rs232SyncPortEntry 3 }       rs232SyncPortTransmitUnderrunErrs OBJECT-TYPE           SYNTAX Counter           ACCESS read-onlyCharacter MIB Working Group                                    [Page 10]

RFC 1317                    RS-232-LIKE MIB                   April 1992           STATUS mandatory           DESCRIPTION               "Total number of frames that failed to be               transmitted on the port since system               re-initialization and while the port state was 'up'               or 'test' because data was not available to the               transmitter in time."           ::= { rs232SyncPortEntry 4 }       rs232SyncPortReceiveOverrunErrs OBJECT-TYPE           SYNTAX Counter           ACCESS read-only           STATUS mandatory           DESCRIPTION               "Total number of frames that failed to be received               on the port since system re-initialization and while               the port state was 'up' or 'test' because the               receiver did not accept the data in time."           ::= { rs232SyncPortEntry 5 }       rs232SyncPortInterruptedFrames OBJECT-TYPE           SYNTAX Counter           ACCESS read-only           STATUS mandatory           DESCRIPTION               "Total number of frames that failed to be received               or transmitted on the port due to loss of modem               signals since system re-initialization and while the               port state was 'up' or 'test'."           ::= { rs232SyncPortEntry 6 }       rs232SyncPortAbortedFrames OBJECT-TYPE           SYNTAX Counter           ACCESS read-only           STATUS mandatory           DESCRIPTION               "Number of frames aborted on the port due to               receiving an abort sequence since system               re-initialization and while the port state was 'up'               or 'test'."           ::= { rs232SyncPortEntry 7 }       -- the Input Signal table       rs232InSigTable OBJECT-TYPE           SYNTAX SEQUENCE OF Rs232InSigEntry           ACCESS not-accessibleCharacter MIB Working Group                                    [Page 11]

RFC 1317                    RS-232-LIKE MIB                   April 1992           STATUS mandatory           DESCRIPTION               "A list of port input control signal entries."           ::= { rs232 5 }       rs232InSigEntry OBJECT-TYPE           SYNTAX Rs232InSigEntry           ACCESS not-accessible           STATUS mandatory           DESCRIPTION               "Input control signal status for a hardware port."           INDEX { rs232InSigPortIndex, rs232InSigName }           ::= { rs232InSigTable 1 }       Rs232InSigEntry ::=           SEQUENCE {               rs232InSigPortIndex                   INTEGER,               rs232InSigName                   INTEGER,               rs232InSigState                   INTEGER,               rs232InSigChanges                   Counter           }       rs232InSigPortIndex OBJECT-TYPE           SYNTAX INTEGER           ACCESS read-only           STATUS mandatory           DESCRIPTION               "The value of rs232PortIndex for the port to which               this entry belongs."           ::= { rs232InSigEntry 1 }       rs232InSigName OBJECT-TYPE           SYNTAX INTEGER { rts(1), cts(2), dsr(3), dtr(4), ri(5),                            dcd(6), sq(7), srs(8), srts(9),                            scts(10), sdcd(11) }           ACCESS read-only           STATUS mandatory           DESCRIPTION               "Identification of a hardware signal, as follows:                   rts    Request to Send                   cts    Clear to Send                   dsr    Data Set Ready                   dtr    Data Terminal ReadyCharacter MIB Working Group                                    [Page 12]

RFC 1317                    RS-232-LIKE MIB                   April 1992                   ri     Ring Indicator                   dcd    Received Line Signal Detector                   sq     Signal Quality Detector                   srs    Data Signaling Rate Selector                   srts   Secondary Request to Send                   scts   Secondary Clear to Send                   sdcd   Secondary Received Line Signal Detector               "           REFERENCE               "EIA Standard RS-232-C, August 1969."           ::= { rs232InSigEntry 2 }       rs232InSigState OBJECT-TYPE           SYNTAX INTEGER { none(1), on(2), off(3) }           ACCESS read-only           STATUS mandatory           DESCRIPTION               "The current signal state."           ::= { rs232InSigEntry 3 }       rs232InSigChanges OBJECT-TYPE           SYNTAX Counter           ACCESS read-only           STATUS mandatory           DESCRIPTION               "The number of times the signal has changed from               'on' to 'off' or from 'off' to 'on'."           ::= { rs232InSigEntry 4 }       -- the Output Signal table       rs232OutSigTable OBJECT-TYPE           SYNTAX SEQUENCE OF Rs232OutSigEntry           ACCESS not-accessible           STATUS mandatory           DESCRIPTION               "A list of port output control signal entries."           ::= { rs232 6 }       rs232OutSigEntry OBJECT-TYPE           SYNTAX Rs232OutSigEntry           ACCESS not-accessible           STATUS mandatory           DESCRIPTION               "Output control signal status for a hardware port."           INDEX { rs232OutSigPortIndex, rs232OutSigName }           ::= { rs232OutSigTable 1 }Character MIB Working Group                                    [Page 13]

RFC 1317                    RS-232-LIKE MIB                   April 1992       Rs232OutSigEntry ::=           SEQUENCE {               rs232OutSigPortIndex                   INTEGER,               rs232OutSigName                   INTEGER,               rs232OutSigState                   INTEGER,               rs232OutSigChanges                   Counter           }       rs232OutSigPortIndex OBJECT-TYPE           SYNTAX INTEGER           ACCESS read-only           STATUS mandatory           DESCRIPTION               "The value of rs232PortIndex for the port to which               this entry belongs."           ::= { rs232OutSigEntry 1 }       rs232OutSigName OBJECT-TYPE           SYNTAX INTEGER { rts(1), cts(2), dsr(3), dtr(4), ri(5),                            dcd(6), sq(7), srs(8), srts(9),                            scts(10), sdcd(11) }           ACCESS read-only           STATUS mandatory           DESCRIPTION               "Identification of a hardware signal, as follows:                   rts    Request to Send                   cts    Clear to Send                   dsr    Data Set Ready                   dtr    Data Terminal Ready                   ri     Ring Indicator                   dcd    Received Line Signal Detector                   sq     Signal Quality Detector                   srs    Data Signaling Rate Selector                   srts   Secondary Request to Send                   scts   Secondary Clear to Send                   sdcd   Secondary Received Line Signal Detector               "           REFERENCE               "EIA Standard RS-232-C, August 1969."           ::= { rs232OutSigEntry 2 }Character MIB Working Group                                    [Page 14]

RFC 1317                    RS-232-LIKE MIB                   April 1992       rs232OutSigState OBJECT-TYPE           SYNTAX INTEGER { none(1), on(2), off(3) }           ACCESS read-only           STATUS mandatory           DESCRIPTION               "The current signal state."           ::= { rs232OutSigEntry 3 }       rs232OutSigChanges OBJECT-TYPE           SYNTAX Counter           ACCESS read-only           STATUS mandatory           DESCRIPTION               "The number of times the signal has changed from               'on' to 'off' or from 'off' to 'on'."           ::= { rs232OutSigEntry 4 }       END6.  Acknowledgements   Based on several private MIBs, this document was produced by the   Character MIB Working Group:      Anne Ambler, Spider      Charles Bazaar, Emulex      Christopher Bucci, Datability      Anthony Chung, Hughes LAN Systems      George Conant, Xyplex      John Cook, Chipcom      James Davin, MIT-LCS      Shawn Gallagher, DEC      Tom Grant, Xylogics      Frank Huang, Emulex      David Jordan, Emulex      Satish Joshi, SynOptics      Frank Kastenholz, Clearpoint      Ken Key, University of Tennessee      Jim Kinder, Fibercom      Rajeev Kochhar, 3Com      John LoVerso, Xylogics      Keith McCloghrie, Hughes LAN Systems      Donalpd Merritt, BRL      David Perkins, 3Com      Jim Reinstedler, Ungerman-Bass      Marshall Rose, PSI      Ron Strich, SSDS      Dean Throop, DGCharacter MIB Working Group                                    [Page 15]

RFC 1317                    RS-232-LIKE MIB                   April 1992      Bill Townsend, Xylogics      Jesse Walker, DEC      David Waitzman, BBN      Bill Westfield, cisco7.  References   [1] Cerf, V., "IAB Recommendations for the Development of Internet       Network Management Standards",RFC 1052, NRI, April 1988.   [2] Cerf, V., "Report of the Second Ad Hoc Network Management Review       Group",RFC 1109, NRI, August 1989.   [3] Rose M., and K. McCloghrie, "Structure and Identification of       Management Information for TCP/IP-based internets",RFC 1155,       Performance Systems International, Hughes LAN Systems, May 1990.   [4] McCloghrie K., and M. Rose, "Management Information Base for       Network Management of TCP/IP-based internets",RFC 1156, Hughes       LAN Systems, Performance Systems International, May 1990.   [5] Case, J., Fedor, M., Schoffstall, M., and J. Davin, Simple       Network Management Protocol",RFC 1157, SNMP Research,       Performance Systems International, Performance Systems       International, MIT Laboratory for Computer Science, May 1990.   [6] McCloghrie K., and M. Rose, Editors, "Management Information Base       for Network Management of TCP/IP-based internets",RFC 1213,       Performance Systems International, March 1991.   [7] Information processing systems - Open Systems Interconnection -       Specification of Abstract Syntax Notation One (ASN.1),       International Organization for Standardization, International       Standard 8824, December 1987.   [8] Information processing systems - Open Systems Interconnection -       Specification of Basic Encoding Rules for Abstract Notation One       (ASN.1), International Organization for Standardization,       International Standard 8825, December 1987.   [9] Rose, M., and K. McCloghrie, Editors, "Concise MIB Definitions",RFC 1212, Performance Systems International, Hughes LAN Systems,       March 1991.  [10] Rose, M., Editor, "A Convention for Defining Traps for use with       the SNMP",RFC 1215, Performance Systems International, March       1991.Character MIB Working Group                                    [Page 16]

RFC 1317                    RS-232-LIKE MIB                   April 19928.  Security Considerations   Security issues are not discussed in this memo.9.  Author's Address   Bob Stewart   Xyplex, Inc.   330 Codman Hill Road   Boxborough, MA 01719   Phone: (508) 264-9900   EMail: rlstewart@eng.xyplex.comCharacter MIB Working Group                                    [Page 17]