Network Working Group                                          A. YasudaRequest for Comments: 1043                                   T. Thompson                                             Defense Intelligence AgencyUpdates: RFC732                                           February 1988TELNET Data Entry Terminal OptionDODIIS ImplementationStatus of this Memo   This RFC suggests a proposed protocol on the TELNET Data Entry   Terminal (DET) Option - DODIIS Implementation for the Internet   community.  It is intended that this specification be compatible with   the specification of DET Option inRFC-732.  Discussion and   suggestions for improvements are encouraged.  Distribution of this   memo is unlimited.Introduction   In the early 1980s, the Defense Intelligence Agency (DIA) undertook   the tasks of developing a TELNET capability to access full screen   applications across a packet switching network.  This effort was   successful by implementing Data Entry Terminal (DET) options within   the TELNET protocol based onRFC 732.  These DET options have been   implemented on IAS, MVS, OS86 and UNIX operating systems.  DET   options are being developed for VM and VMS operating systems.   The Department of Defense Intelligence Information System (DODIIS) is   a confederation of heterogeneous computer systems and remote   terminals utilizing the Defense Data Network (DDN) as the   communications backbone (namely the SCINET/DSNET-3).   Although the reason for implementing a DET option specification was   based upon data base application interfaces, the use of a full screen   TELNET provides a method to achieve higher efficiency on the network.   Most terminal to host applications on the ARPANET are character echo   TELNETs.  This is both costly in time and network utilization, since   one character pressed on the keyboard generates a datagram composed   of TCP/IP headers plus the character sent to the host and the host   echoes back a similar datagram.  In the DODIIS community, programmers   are highly encouraged to implement full screen applications; line at   a time is acceptable; and character remote echo mode is discouraged.   This RFC in its final form will be implemented on SCINET.  During the   interim period, the "DODIIS TELNET Network Virtual Data Entry   Terminal (NVDET) Option Specification", DIA, April 1983, will be   implemented.Yasuda & Thompson                                               [Page 1]

RFC 1043              Data Entry Terminal - DODIIS         February 1988                             TABLE OF CONTENTS                                                                Page No.                                                                --------SECTION 1   COMMAND NAME AND OPTION CODE                          4SECTION 2   COMMAND MEANINGS                                      4                 Facilities Subcommands                              4                 Edit Subcommands                                    8                 Transmit Subcommands                                8                 Erase Subcommands                                  10                 Format Subcommands                                 10                 Miscellaneous Subcommands                          13SECTION 3   DEFAULT AND MINIMAL IMPLEMENTATION                   15SECTION 4   MOTIVATION FOR THE OPTION                            17SECTION 5   DESCRIPTION AND IMPLEMENTATION RULES                 17                 The DODIIS DET Model                               17                 Negotiating the DET Option                         18                 DET Facilities Negotiation                         18                 General DET Interaction                            19                 Form Construction                                  20                 Form response                                      21                 Function Keys                                      22                 Field Selection                                    22                 Out-Of-Context Data                                23                 Line Discipline                                    23                 Standard TELNET Control Functions                  24                 Other Implementation Notes                         24   APPENDIX 1  DET OPCODES AND SUBCOMMAND SYNTAX                    25   APPENDIX 2  DET ERROR CODES                                      26Yasuda & Thompson                                               [Page 2]

RFC 1043              Data Entry Terminal - DODIIS         February 1988   The convention in the documentation of the TELNET NVDET Protocol is   to express numbers in decimal.  Data fields are described left to   right, with the most significant octet on the left and the least   significant octet on the right.   The order of transmission of the data described in this document is   resolved to the octet level.  Whenever a diagram shows a group of   octets, the order of transmission of those octets is the normal order   in which they are read in English.  For example, in the following   diagram the octets are transmitted in the order they are numbered.       0                   1                   2                   3       0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1      +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+      |       1       |       2       |       3       |       4       |      +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+      |       5       |       6       |       7       |       8       |      +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+      |       9       |      10       |      11       |      12       |      +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+                        Transmission Order of Bytes   Whenever an octet represents a numeric quantity, the left most bit in   the diagram is the high order or most significant bit.  That is, the   bit labeled 0 is the most significant bit.  For example, the   following diagram represents the value 170 (decimal).                              0 1 2 3 4 5 6 7                             +-+-+-+-+-+-+-+-+                             |1 0 1 0 1 0 1 0|                             +-+-+-+-+-+-+-+-+                           Significance of Bits   Similarly, whenever a multi-octet field represents a numeric   quantity, the left most bit of the whole field is the most   significant bit.  When a multi-octet quantity is transmitted the most   significant octet is transmitted first.Yasuda & Thompson                                               [Page 3]

RFC 1043              Data Entry Terminal - DODIIS         February 1988   1. Command Name and Option Code      DET         20   2. Command Meanings      IAC WILL DET         The sender of this command REQUESTS permission to begin, or         AGREES that it will begin, sending and receiving Data Entry         Terminal (DET) subcommands to control session interactions.      IAC WONT DET         If the connection is already operating in DET mode, the sender         of this command DEMANDS that the connection stop operating in         DET mode and begin operating in TELNET NVT mode.  If the         connection is not operating in DET mode, the sender REFUSES to         begin operating in DET mode.  A connection is operating in         TELNET NVT mode when both parties are interpreting data as         described by the TELNET SPECIFICATION, MIL-STD-1782.      IAC DO DET         The sender of this command REQUESTS permission to begin, or         AGREES that it will begin, sending and receiving Data Entry         Terminal (DET) subcommands to control session interactions.      IAC DONT DET         If the connection is already operating in DET mode, the sender         of this command DEMANDS that the connection stop operating in         DET mode and begin operating in TELNET NVT mode.  If the         connection is not operating in DET mode, the sender REFUSES  to         begin  operating in DET mode.    A connection is operating in         TELNET NVT mode when both parties are interpreting data as         described by the TELNET SPECIFICATION, MIL-STD-1782.      DODIIS implementations of the DET option use the subcommands      described in the remainder ofSection 2.  A description of the      DODIIS DET model and DET subcommand usage is contained inSection5.   FACILITIES SUBCOMMANDS.  Facilities subcommands are used to negotiate   DET facilities (subcommands and attributes).  The facility   subcommands indicate the DET facilities the sender supports.   Facility negotiation may be viewed as the terminal indicating the   facilities it provides and the application indicating the facilitiesYasuda & Thompson                                               [Page 4]

RFC 1043              Data Entry Terminal - DODIIS         February 1988   it desires.  The bits of the facility maps are numbered from the   right starting at zero.  Thus, if bit 2 is set, the field will have a   decimal value of 4.      IAC SB DET EDIT-FACILITIES <facility map> IAC SE         subcommand code:  1         This subcommand indicates the edit facilities the sender         supports.  The <facility map> parameter is one eight bit byte         containing the following flags:             Bits 5-7        Reserved             Bit  4          Read Cursor             Bits 0-3        Reserved         where:             If the Read-Cursor bit is set, the sender supports the             READ-CURSOR and CURSOR-POSITION subcommands.             Reserved bits represent edit facilities that are not             defined for DODIIS implementations;  therefore, no             descriptions are provided.  Reserved bits must be zeroed             to indicate non support of the associated edit facilities.      IAC SB DET ERASE-FACILITIES <facility map> IAC SE         subcommand code:  2         This subcommand indicates the erase facilities the sender         supports.  The <facility map> parameter is one eight bit         byte containing flags.  Since no erase facilities are         defined for DODIIS implementations, no descriptions are         provided.  The ERASE-FACILITIES subcommand is part of the         minimal DET implementation and is included for that reason.         DODISI implementors must declare non support of erase         facilities by sending this subcommand with a zeroed facility         map.      IAC SB DET TRANSMIT-FACILITIES <facility map> IAC SE         subcommand code:  3         This subcommand indicates the transmit facilities the sender         supports.  The <facility map> parameter is one eight bit byte         containing the following flags:Yasuda & Thompson                                               [Page 5]

RFC 1043              Data Entry Terminal - DODIIS         February 1988             Bits 6-7        Reserved             Bit  5          Data Transmit             Bits 0-4        Reserved         where:             If the Data-Transmit bit is set, the sender supports the             DATA-TRANSMIT subcommand.             Reserved bits represent transmit facilities that are not             defined for DODIIS implementations; therefore, no             descriptions are provided.  Reserved bits must be zeroed             to indicate non support of the associated transmit             facilities.      IAC SB DET FORMAT-FACILITIES <facility map> IAC SE         subcommand code:  4         This subcommand indicates the format facilities the sender         supports.  The <facility map> parameter is two eight bit bytes         containing the following:             Byte 0                Bit  7       Function Key                Bit  6       Modified                Bit  5       Field Selection                Bit  4       Repeat                Bit  3       Blinking                Bit  2       Reverse Video                Bit  1       Right Justification                Bit  0       Reserved             Byte 1                Bit  7       Reserved for color                Bit  6       Reserved                Bit  5       Protection                Bit  4       Alphabetic-Only                Bit  3       Numeric-Only                Bits 0-2     Intensity             where:                If the Function-Key bit is set, the sender supports the                FUNCTION-KEY and ENABLE-FUNCTION-KEY subcommands.                If the Modified bit is set, the sender supports the                FORMAT-DATA subcommand's Modified attribute and theYasuda & Thompson                                               [Page 6]

RFC 1043              Data Entry Terminal - DODIIS         February 1988                TRANSMIT-MODIFIED subcommand.                If the Field-Selection bit is set, the sender supports                the FORMAT-DATA subcommand's Selectable attribute and                the SELECTED-FIELD subcommand.                If the Repeat bit is set the sender supports the REPEAT                subcommand.                If the Blinking bit is set, the sender requests or                provides the ability to emphasize a string of characters                by causing them to blink when displayed.  (See the                FORMAT-DATA subcommand.)                If the Reverse-Video bit is set, the sender requests or                provides the ability to emphasize a string of characters                by "reversing their video image".  If characters are                normally displayed as dark characters on a light                background, they are reversed and displayed as light                characters on a dark background, or                vice versa.  (See the FORMAT-DATA subcommand.)                If the Right-Justification bit is set, the sender                requests or provides the ability to cause data entered                in a field to be right justified within the field.  (See                the FORMAT-DATA subcommand.)                If the Protection bit is set, the sender requests or                provides the ability to protect certain fields displayed                on the DET screen from being altered by the user and                supports the ERASE-UNPROTECTED, FIELD-SEPARATOR, and                TRANSMIT-UNPROTECTED subcommands.  (See the FORMAT-DATA                subcommand.)                If the Alphabetic-Only bit is set, the sender requests                or provides the ability to constrain the user of the DET                such that only alphabetic data may be entered into                certain fields.  (See the FORMAT-DATA subcommand.)                If the Numeric-Only bit is set, the sender requests or                provides the ability to constrain the user of the DET                such that only numeric data may be entered into certain                fields.  (See the FORMAT-DATA subcommand.)                The Intensity parameter is three bits wide and is                interpreted as a positive binary integer indicating the                number of visible levels of intensity that the sender                requests or provides for displaying data.  (See theYasuda & Thompson                                               [Page 7]

RFC 1043              Data Entry Terminal - DODIIS         February 1988                FORMAT-DATA subcommand.)                Reserved bits represent format facilities that are not                defined for DODIIS implementations; therefore, no                descriptions are provided.   Reserved bits must be                zeroed to indicate non support of the associated format                facilities.   EDIT SUBCOMMANDS.  Edit subcommands are sent by the application to   position the cursor on the DET screen.      IAC SB DET MOVE-CURSOR <x><y> IAC SE         subcommand code:  5         This subcommand positions the DET cursor at screen location         (x,y).  the <x> and <y> parameters are positive eight bit         binary integers representing the character and line positions,         respectively, of a DET screen location.  Values of x range         from zero (0) through M-1, where M is the DET screen width in         characters.  Values of y range from zero (0) through N-1,         where N is the DET screen length in lines.      IAC SB DET HOME-CURSOR IAC SE         subcommand code: 12         This subcommand positions the cursor at DET screen address         (0,0).  It is equivalent to the MOVE-CURSOR subcommand, where         x=0 and y=0.   TRANSMIT SUBCOMMANDS.  Transmit subcommands are sent by the   application to request data from the DET or by the terminal to   identify data returned from the DET.      IAC SB DET READ-CURSOR IAC SE         subcommand code: 17         This subcommand requests return of the DET cursor position.         Use of this subcommand requires facility negotiation; see the         EDITFACILITIES subcommand, Read-Cursor bit.      IAC SB DET CURSOR-POSITION <x><y> IAC SE         subcommand code: 18         This subcommand returns cursor position in response to aYasuda & Thompson                                               [Page 8]

RFC 1043              Data Entry Terminal - DODIIS         February 1988         READCURSOR subcommand.  The <x> and <y> parameters are         eight bit binary integers representing the cursor's position.         The <x> and <y> parameters are positive eight bit binary         integers representing the character and line positions,         respectively, of a DET screen location.  Values of x range         from zero (0) through M-1, where M is the DET screen width in         characters.  Values of y range from zero (0) through N-1,         where N is the DET screen length in lines.  Use of this         subcommand requires facility negotiation; see the         EDIT-FACILITIES subcommand, Read-Cursor bit.      IAC SB DET TRANSMIT-SCREEN IAC SE         subcommand code: 20         This subcommand requests return of all characters on the DET         screen beginning at cursor position (0,0).  M x N characters,         where M is the DET screen width in characters and where N is         the DET screen length in lines, are returned with a SPACE         character returned for each character in the unwritten areas         (the areas between defined fields).  FIELD-SEPARATOR and         DATA-TRANSMIT subcommands are not required to delimit or         identify fields.      IAC SB DET TRANSMIT-UNPROTECTED IAC SE         subcommand code: 21         This subcommand requests return of all characters in         unprotected fields.  Use of this subcommand requires facility         negotiation; see the FORMAT-FACILITIES subcommand, Protection         bit.      IAC SB DET TRANSMIT-MODIFIED IAC SE         subcommand code: 27         This subcommand requests return of all characters in modified         fields.  Modified fields are fields that have the Modified         attribute set (see FORMAT-DATA subcommand) as well as fields         actually modified by the user.  Use of this subcommand         requires facility negotiation; see the FORMAT-FACILITIES         subcommand, Modified bit.      IAC SB DET DATA-TRANSMIT <x><y> IAC SE         subcommand code: 28Yasuda & Thompson                                               [Page 9]

RFC 1043              Data Entry Terminal - DODIIS         February 1988         This subcommand identifies a field returned in response to         a TRANSMIT-MODIFIED subcommand.  The <x> and <y> parameters         are positive eight bit binary integers indicating the cursor         position of the field that follows the DATA-TRANSMIT         subcommand.  This subcommand may precede the first field of         a transmission with subsequent fields separated by the         FIELD-SEPARATOR subcommand or it may precede each field.         Use of this subcommand requires facility negotiation; see         the TRANSMIT-FACILITIES subcommand, Data-Transmit bit.   ERASE SUBCOMMANDS.  Erase subcommands are used by the application to   erase the DET screen or selected DET screen areas.  In performing   erase operations, the erased characters are replaced with SPACE   characters.      IAC SB DET ERASE-SCREEN IAC SE         subcommand code: 29         This subcommand erases all characters from the DET screen.         All fields regardless of their attributes are deleted.  The         cursor position after the operation is at (0,0).  If the         protection attribute has been negotiated, the erased screen         contains protected SPACE characters.      IAC SB DET ERASE-UNPROTECTED IAC SE         subcommand code: 35         This subcommand erases all characters in the unprotected fields         of the DET screen.  This subcommand replaces field contents         with SPACE characters; field attributes and sizes are not         changed.  The cursor position after the operation is at the         beginning of the first unprotected field or, if there is no         unprotected field, at (0,0).  Use of this subcommand requires         facility negotiation; see the FORMAT-FACILITIES subcommand,         Protection bit.   FORMAT SUBCOMMANDS.  The format subcommands are used by the   application to define the fields of a form and by the terminal to   delimit fields sent from the DET.      IAC SB DET FORMAT-DATA <format map><count> IAC SE         subcommand code: 36         This subcommand defines the attributes and size of a DET field.         The <format map> parameter defines the field attributes and theYasuda & Thompson                                              [Page 10]

RFC 1043              Data Entry Terminal - DODIIS         February 1988         <count> parameter defines the field size.  The field starts at         the position of the cursor when the subcommand is acted upon.         The next <count> data characters in the data stream fill the         field.         The <format map> parameter is two eight bit bytes and contains         the following:             Byte 0                Bit  7             Blinking                Bit  6             Reverse Video                Bit  5             Right Justification                Bits 3-4           Protection                Bits 0-2           Intensity             Byte 1                Bits 5-7           Reserved                Bits 2-4           Reserved for color                Bit  1             Modified                Bit  0             Selectable             where:                If the Blinking bit is set, the following field of                 <count> characters should have the Blinking attribute                applied to it by the receiver.                If the Reverse Video bit is set, the following field of                <count> characters should be displayed by the receiver                with video reversed.                If the Right Justification bit is set, characters                entered into the field by the user should be right                justified.                The Protection attribute is two bits wide and may take                on the following values:                  0  No protection.  Any valid DET data character may                     be entered in the field.                  1  Protected.  No data may be entered in the field.                  2  Alphabetic-only.  Only the alphabetic characters                     (A-Z and a-z) or the space character may be                     entered in the field.                  3  Numeric-only.  Only the numeric characters (0-9),Yasuda & Thompson                                              [Page 11]

RFC 1043              Data Entry Terminal - DODIIS         February 1988                     the plus sign (+), the minus sign (-), the decimal                     point (.) or the space character may be entered in                     the field.                The Intensity attribute is three bits wide and indicates                the brightness to be used when displaying the characters                in or entered into the field <count> characters wide.                The available number of visible intensity levels should                have been negotiated using the FORMAT-FACILITY                subcommand. A value of zero (0) indicates that                brightness should be OFF; that is, characters in or                entered into the field should not be displayed.  The                values 1-7 indicate relative brightness; the exact                algorithm for mapping these values to the available                levels of intensity is left to the implementors.                If the Modified bit is set, the field is considered to                have been modified and will be returned, along with any                user modified fields.                If the Selectable bit is set, the field is a candidate                for field selection using the DET field selection                device.      The <count> parameter is two bytes and should be interpreted as a      positive 16-bit binary integer that defines the field size.  The      high order bit is transmitted first.  Data, not in the scope of      the count of a FORMAT-DATA subcommand, should be displayed with      the default field attributes (no blinking, no reverse video, no      justification, no protection, not modified, not selectable, and a      visible intensity).  Minimum field size is one (1) character.      Maximum field size is determined by a field's starting location      and the end of the screen or the start of the next field.      Use of field attributes requires facility negotiation; see the      FORMAT-FACILITIES subcommand.   IAC SB DET REPEAT <count><char> IAC SE         subcommand code: 37         This subcommand permits compression of DET data by encoding         strings of identical characters as the character and a repeat         count.  The <count> parameter is a positive 8-bit binary         integer.  The <char> parameter is a valid DET data character.         Use of this subcommand requires facility negotiation; see         the FORMAT-FACILITIES subcommand, Repeat bit.Yasuda & Thompson                                              [Page 12]

RFC 1043              Data Entry Terminal - DODIIS         February 1988      IAC SB DET FIELD-SEPARATOR IAC SE         subcommand code: 39         This subcommand separates fields returned by the DET in         response to TRANSMIT-MODIFIED or TRANSMIT-UNPROTECTED         subcommands.  Use of this subcommand requires facility         negotiation; see the FORMAT-FACILITIES subcommand,         Protection bit.MISCELLANEOUS SUBCOMMANDS      IAC SB DET FUNCTION-KEY <code> IAC SE         subcommand code: 40         This subcommand transmits a user entered function key code.         The <code> parameter is one byte that identifies the virtual         function key entered.  Function key <code> values range from         0 to 255.  This subcommand is used in conjunction with the         ENABLE-FUNCTION-KEY subcommand.  Use of this subcommand         requires facility negotiation; see the FORMAT-FACILITIES         subcommand, Function-Key bit.      IAC SB DET ERROR <cmd><error code> IAC SE         subcommand code: 41         This subcommand allows a DET option implementation to report         errors it detects to the corresponding TELNET process.  The         <cmd> parameter is one byte containing the subcommand code         of the subcommand causing the error.  The <error code>         parameter is one byte containing a DET error code.  (See         Appendix 2 for DET error codes.)         Errors should be reported when detected.  However, the         implementation should attempt to carry out the intent of         the subcommand or data in error.      IAC SB DET START-OUT-OF-CONTEXT-DATA IAC SE         subcommand code: 42         This subcommand precedes out-of-context data.  The data         following this subcommand and prior to the         END-OUT-OF-CONTEXT-DATA subcommand is NOT part of the current         form.  The out-out-of-context data should be interpreted as         NVT mode data (i.e., it may contain carriage return and lineYasuda & Thompson                                              [Page 13]

RFC 1043              Data Entry Terminal - DODIIS         February 1988         feed characters) and should be displayed in a timely and         non-destructive fashion.      IAC SB DET END-OUT-OF-CONTEXT-DATA IAC SE         subcommand code: 43         This subcommand indicates the end of the out-of-context data.      IAC SB DET ENABLE-FUNCTION-KEYS <key-map>IAC SE         subcommand code: 44         This subcommand enables (or disables) virtual function keys and         indicates the application's data requirements on function key         selection.  The <key-map> parameter is a variable length byte         string.  Each byte contains four bit-pairs and each bit-pair         represents a single function key.  The first byte represents         function keys zero (0) through three (3); the second byte,         function keys four (4) through seven (7); and so on.  Bit-pair         values and there meanings are as follows:             0  The virtual function key is disabled (i.e., locked).             1  The virtual function key is enabled.  Only the FUNCTION-                KEY subcommand is returned on function key selection.             2  The  virtual  function  key  is  enabled.  All requested                screen data and/or cursor position, as well as, the                FUNCTION-KEY subcommand are returned on function key                selection.             3  Undefined.         Function keys not explicitly represented in the bitmap are         disabled (i.e., they are assumed to have a bit-pair value of         zero (0)).         Use of this subcommand requires facility negotiation; see the         FORMAT-FACILITIES subcommand; Function-Key bit.      IAC SB DET SELECTED-FIELD <x><y> IAC SE         subcommand code: 45         This subcommand identifies a user selected field.  The <x> and         <y> parameters are the cursor position of the character         selected from within a selectable field (see the FORMAT-DATAYasuda & Thompson                                              [Page 14]

RFC 1043              Data Entry Terminal - DODIIS         February 1988         subcommand, Selectable attribute.)  Use of this subcommand         requires negotiation; see the FORMAT-FACILITIES subcommand,         Field-Selection bit.3. Default and Minimal Implementation      Default.         WONT DET -- DONT DET         If the DET option cannot be negotiated, the connection is         not operated in DET mode.      Minimal DET Implementation.         The minimal DET implementation consists of all DET subcommands         that may be used without prior negotiation.  These subcommands         are as follows:             EDIT-FACILITIES             ERASE-FACILITIES             TRANSMIT-FACILITIES             FORMAT-FACILITIES             MOVE-CURSOR             HOME-CURSOR             ERASE-SCREEN             TRANSMIT-SCREEN             FORMAT-DATA             ERROR             START-OUT-OF-CONTEXT-DATA             END-OUT-OF-CONTEXT-DATA      DODIIS DET implementation requirements.         The minimal DET implementation set of subcommands is not broad         enough to support forms interactions between DODIIS terminals         and DODIIS applications.  Therefore, DODIIS implementations of         the DET option must support additional DET subcommands.         DODIIS terminal (User Host) implementations must implement and         support all of the DET subcommands contained inSection 2, as         well as those DET attributes supported by the terminal hardware         and any DET attributes easily emulated in software.  DODIIS         application (Server Host) implementations must implement and         support those DET subcommands and attributes required by its         applications.Yasuda & Thompson                                              [Page 15]

RFC 1043              Data Entry Terminal - DODIIS         February 1988         DODIIS implementation recommendations are contained in the         table that follows.  DODIIS implementors are cautioned that         failure to provide recommended support may limit         interoperability.         Recommended DET support levels for DODIIS implementations                                      USER HOST           SERVER HOST      DET SUBCOMMANDS                 SUPPORT LEVEL       SUPPORT LEVEL      ---------------                 -------------       -------------      EDIT-FACILITIES                 send & receive      send & receive      ERASE-FACILITIES                send & receive      send & receive      TRANSMIT-FACILITIES             send & receive      send & receive      FORMAT-FACILITIES               send & receive      send & receive      REPEAT                          send & receive      send & receive      ERROR                           send & receive      send & receive      MOVE-CURSOR                     receive only        send only      HOME-CURSOR                     receive only        send only      READ-CURSOR                     receive only        send only      TRANSMIT-SCREEN                 receive only        send only      TRANSMIT-UNPROTECTED            receive only        send only      TRANSMIT-MODIFIED               receive only        send only      ERASE-SCREEN                    receive only        send only      ERASE-UNPROTECTED               receive only        send only      FORMAT-DATA                     receive only        send only      START-OUT-OF-CONTEXT-DATA       receive only        send only      END-OUT-OF-CONTEXT-DATA         receive only        send only      ENABLE-FUNCTION-KEYS            receive only        send only      CURSOR-POSITION                 send only           receive only      DATA-TRANSMIT                   send only           receive only      FIELD-SEPARATOR                 send only           receive only      FUNCTION-KEY                    send only           receive only      SELECTED-FIELD                  send only           receive only      DET ATTRIBUTES      --------------      Blinking                        (1)                 (2)      Reverse video                   (1)                 (2)      Right justification             (1)                 (2)      Protection                      required            (2)      Alphabetic-only protection      (1)                 (2)      Numeric-only protection         (1)                 (2)      Intensity level > 1             (1)                 (2)      OTHER      -----      Page size (lines)               24-48      Line size (characters)          80Yasuda & Thompson                                              [Page 16]

RFC 1043              Data Entry Terminal - DODIIS         February 1988      Function keys (number)          64         (1)   Implement if supported by terminal hardware.         (2)   Implement if required by the application.4.  Motivation for the option   In 1981, the TELNET DET option (RFC 732) was selected as the protocol   to support interactions between DODIIS forms applications and DODIIS   forms terminals.  The intent was to foster a high degree of   interoperability between DODIIS hosts with forms applications and   terminals.  Since that time, the DET option has been and is being   implemented by several independent organizations within the DODIIS   community.   Motivated by concern that the independently developed implementations   of the DET option may not interoperate with one another, DODIIS   implementors met to identify DODIIS implementation requirements and   to resolve implementation issues that affect interoperability.   This document attempts to present the agreements and recommendations   of the DODIIS implementors.5.  Description and Implementation Rules   The DODIIS DET model.   The conceptual model of the DODIIS DET is that of a half-duplex,   forms oriented device with the following:      a.  A rectangular screen for displaying protected and unprotected         data (a form) and optional capability to support blinking,         reverse video, and up to seven display intensity levels.      b.  A keyboard and onboard mechanisms for editing unprotected         fields of a form and returning the modified fields.      c.  Function keys that may be enabled and disabled on a key-by-key         basis by the application.      d.  A field selection device, similar to a light pen, that permits         user selection of characters within appropriately identified         "selectable" fields.   The DODIIS DET screen has default sizes of 80 characters and 24   lines.  These defaults may be changed through negotiation using the   Output Line Width and the Output Page Size options.  When the partiesYasuda & Thompson                                              [Page 17]

RFC 1043              Data Entry Terminal - DODIIS         February 1988   cannot agree on screen size through negotiation, the default values   will be used.  By agreement, DODIIS terminal (User Host)   implementations of DET will support page sizes of 24 to 48 lines.   The next writing position (x,y) on the DET screen is indicated by a   special display character called the cursor, where x is the position   of a character on a line and y is the line position on the DET   screen.  Values of x range from 0 (the left most character position   on the line) to M-1, where M is the line length.  Values of y range   from 0 (the top most line on the screen) to N-1, where N is the page   length.  The cursor may be moved to any position on the DET screen   without disturbing the characters already displayed.   Valid field data for DET forms are the displayable ASCII character   codes in the range 32 through 126 decimal and character 7 "BELL".   Negotiating the DET option      The DET option is negotiated when either party REQUESTS use of the      DET option and the other party AGREES to its use.  The DET option      is requested by sending a DO DET and WILL DET and is accepted by      sending a WILL DET and DO DET.  (In the spirit of TELNET      negotiation, the DET option must be negotiated for both directions      on the connection.)      Several TELNET options conflict with the DET option.  Therefore,      when the DET option is negotiated, the following TELNET options      should be refused (or explicitly terminated):  Echo, Suppress Go-      Ahead, and Binary.  (The Suppress Go-Ahead is the default state of      DODIIS TELNET connections when they are first established.)   DET facilities negotiation      All implementations of the DET option are required to support the      minimal DET implementation described inSection 3.  In addition,      DODIIS implementations are required to support subcommands and      attributes that are consistent with DODIIS implementation      requirements.  Before any of these additional DET facilities may      be used, an implementation must negotiate with its correspondent      for permission to use them.      The four facility subcommands (EDIT-FACILITIES, ERASE-FACILITIES,      TRANSMIT-FACILITIES, and FORMAT-FACILITIES) are used to negotiate      DET subcommands and attributes.  This negotiation consists of an      exchange of facility subcommands and may be viewed as the terminal      (User Host) indicating the facilities it provides and the      application program (Server Host) indicating the facilities it      desires.  The facilities that are jointly supported (and may beYasuda & Thompson                                              [Page 18]

RFC 1043              Data Entry Terminal - DODIIS         February 1988      used) are arrived at by forming the logical intersection of the      facility map that was sent with the facility map that was      received.  (For the intensity attribute, the lesser of the number      of intensity levels sent and the number of intensity levels      received will be used.)  An implementation must record the      currently agreed upon set of subcommands and attributes.  Only      subcommands and attributes reflected in that set may be used      without further exchange of facility subcommands.      Either party or both parties may initiate facilities negotiation      without confusion as long as care is taken to avoid non-      terminating negotiation loops.  In particular, if you initiate      negotiation by sending a facility subcommand, you must remember      that you did initiate the negotiation.  On receipt of a facility      subcommand; if you initiated the negotiation, no response is      required and the negotiation is complete; if you did not initiate      the negotiation, you must respond by sending the appropriate      facility subcommand to the requester.  (Note that there is no      requirement to negotiate facilities one class at a time and that      the awareness of who initiated the negotiation must be maintained      for each of the facility subcommands.)      A TELNET implementation responding to a facility subcommand is not      required to compute the logical intersection of the maps before      responding.  It should respond as quickly as possible with a      facility map indicating all facilities of that class that it      supports.  There is no confusion since both parties compute the      set of supported subcommands and attributes in the same fashion.      Note that while both parties must agree to the use of the optional      subcommands and attributes, either party may disable use at any      time by merely sending the appropriate facility subcommand.      Further, there are no restrictions on when facilities may be sent.                                   CAUTION:                 All facilities maps contain reserved bits.                 These reserved bits must be zeroed when                 facility maps are sent to indicate non                 support and/or ignorance of the associated                 facility.  The reserved bits may be defined                 in the future.   General DET Interaction      In the general interaction, the application implementation      constructs a form, negotiates the desired options, indicates the      required responses, and sends the TELNET GO-AHEAD.  The GO-AHEAD      signals that the form construction is complete and that the DETYasuda & Thompson                                              [Page 19]

RFC 1043              Data Entry Terminal - DODIIS         February 1988      keyboard may be unlocked to permit a user response.      The user normally responds by editing the unprotected areas of the      form and signaling "form-complete", entering a function key,      electing a field, or performing a combination of the preceding.      In each case, the terminal implementation sends the DET      subcommands indicating the user's response and returns the GO-      AHEAD.  The GO-AHEAD signals the end of the user response.      The form, as edited by the user, remains on the virtual screen so      the application may continue the interaction by altering the form.   Form construction      The application implementation constructs a form on an erased      screen by defining each of the fields in the form.  The DET fields      are defined by their starting cursor position, size, attributes,      and contents (data).      A field's starting cursor position is the cursor position of the      first character in the field.  The cursor may be positioned      explicitly by the MOVE-CURSOR subcommand or it may be positioned      implicitly by field data or other DET subcommands (e.g.,      ERASESCREEN and ERASE-UNPROTECTED).      Field size, attributes, and contents may be defined using the      FORMAT-DATA subcommand followed by field data.  Alternatively, a      field with default attributes may be defined using only the field      data.  In this case, field size is the data string length.  The      data string is terminated by the GO-AHEAD or any DET subcommand,      except the REPEAT subcommand.      There are no restrictions on attribute combinations that might be      applied to a field even though some combinations may not be      supported by terminal hardware.  The terminal implementation      should display the field with a "reasonable" combination of      attributes.  There is an error code that might be returned when an      "unsupported combination of format attributes" is detected.  It is      not clear what the application should do about the error.  In any      event, this condition should not provoke session termination.      Field contents (data) are restricted to printable ASCII characters      and "BELL" (codes 32 through 126 and 7 decimal).  It is the      responsibility of the application implementation to properly      translate carriage returns, line feeds, tabs, etc.  to the      appropriate DET subcommands.      The maximum number of fields a screen might contain is the screenYasuda & Thompson                                              [Page 20]

RFC 1043              Data Entry Terminal - DODIIS         February 1988      size in characters (the product of characters per line and lines      per screen).      Fields may not overlap.  That is, a new field may not start or end      within a previously defined field.  However, overwriting of a      field to change its attributes or contents is permitted.      There are no restrictions on the order in which a form is built      (e.g., left-to-right and top-to-bottom); the terminal      implementation must be prepared to handle any order.  Terminal      implementations are encouraged to display data as it arrives to      accommodate applications that persist in displaying status updates      on the task(s) they are performing.      If an application elects to modify a user edited form, it must      properly position the cursor making no assumptions about where the      user might have left the cursor.  Further it must exactly      overwrite the existing fields.      When form construction is complete, the application indicates its      response requirements by sending the appropriate transmit      subcommand.  It may send TRANSMIT-SCREEN, TRANSMIT-UNPROTECTED, or      TRANSMIT-MODIFIED to request data and/or it may send READ-CURSOR      to request cursor position.  TRANSMIT-MODIFIED should be used      whenever possible to minimize the volume of data transmitted      between user and server hosts.   Form response      A form response is generated by the terminal implementation when      the user signals "form-complete" or enters an enabled function      key.  The data returned are determined by the application through      the transmit subcommands.  If no transmit subcommand was sent the      Modified and Protection attributes are used to determine an      implied transmit subcommand.  If the Modified attribute has been      negotiated, assume TRANSMIT-MODIFIED.  If the Protection attribute      has been negotiated but the Modified has not, assume      TRANSMITUNPROTECTED.  If neither has been negotiated, assume      TRANSMITSCREEN.  (The intent is to achieve transmission efficiency      by returning the smallest amount of data permitted by the in-force      DET attributes.)                                   CAUTION:              With TRANSMIT-MODIFIED the terminal implementation              must return all fields marked with the Modified              attribute in addition to fields actually modified by              the terminal user.Yasuda & Thompson                                              [Page 21]

RFC 1043              Data Entry Terminal - DODIIS         February 1988      Returned fields are identified and delimited using the      DATATRANSMIT and/or FIELD-SEPARATOR subcommands.  The DATA-      TRANSMIT subcommand indicates the cursor address of the field that      follows it and there are no restrictions on the order in which      fields are returned.  The FIELD-SEPARATOR subcommand conveys      left-to-right and top-to-bottom field ordering.  Data not preceded      by one of these subcommands is assumed to be the first unprotected      field in the form.  A FIELD-SEPARATOR followed by FIELD-SEPARATOR      indicates a field was unchanged and not returned.      Unless otherwise restricted by Numeric-only or Alphabetic-only      attributes, data entered into unprotected fields is restricted to      the printable ASCII characters and "BELL" (codes 32 through 126      and 7 decimal); no other characters are permitted.   Function keys      By general agreement, DODIIS terminal implementations will support      64 function keys (key values 0 through 63).  Information on      mapping function keys to application functions is the      responsibility of the application and should be provided to the      terminal user in the form of user documentation.      The application enables and disables the function keys and      indicates its form response requirements by sending the      ENABLEFUNCTION-KEY subcommand.  The terminal implementation      validates function key selections based on information received in      the ENABLE-FUNCTION-KEY bitmap.  When an enabled function key is      entered, the terminal returns a form response (if indicated in the      bitmap), a FUNCTION-KEY subcommand, and the GO-AHEAD.      Virtual function keys are part of the DET's virtual keyboard and      are "locked" when the application has the GO-AHEAD.  Since the      terminal sends the GO-AHEAD when a function key is entered,      entering a function key "re-locks" all function keys until the      GO-AHEAD is returned.   Field selection      Any character within a field having the Selectable attribute is a      candidate for selection.  When selection is made, the terminal      returns a SELECTED-FIELD subcommand identifying the character      position selected.  Multiple selections are permitted; however,      the ordering of the selections need not be preserved.  Field      selection does not cause the GO-AHEAD to be sent.  The GO-AHEAD      must be sent as a result of another user action such as a function      key entry or "form-complete" indication.  Field selection is      disabled when the application has the GO-AHEAD.Yasuda & Thompson                                              [Page 22]

RFC 1043              Data Entry Terminal - DODIIS         February 1988   Out-of-context data      The out-of-context-data subcommands identify data that is clearly      not in the context of the form interaction.  It is a convenient      not in the mechanism for sending ARE-YOU-THERE responses or host      advisory messages to the user without disturbing the DET's virtual      screen or altering the context of the form interaction.      The application may send out-of-context data at anytime.  The data      must be preceded by the START-OUT-OF-CONTEXT-DATA subcommand and      followed immediately by the END-OUT-OF-CONTEXT-DATA subcommand.      The out-of-context data should contain carriage returns and line      feeds to facilitate formatting.  The sender should limit the      amount of data sent, since most terminal implementations must      buffer the data prior to displaying it.  The terminal      implementation should display the data to the user in a timely      fashion.  The data is for display only, no user response is      required, and there is no mechanism for user response.   Line Discipline      The subject of DET and line discipline (controlling the connection      using the GO-AHEAD) causes a bit of confusion.  The following      rules apply to GO-AHEAD and the DET option:         When DET is negotiated, the application assumes the GO-AHEAD.         GO-AHEAD is never passed implicitly; it is always passed         explicitly.         When the application has the GO-AHEAD, the terminal         implementation may send TELNET commands (INTERRUPT-PROCESS,         ABORT-OUTPUT, BREAK, and ARE-YOU-THERE).  Nothing else is         valid.         When the terminal has the GO-AHEAD, the application may send         out-of-context data or MOVE-CURSOR and FORMAT-DATA subcommands         to update protected fields.  Nothing else is valid.  (The         terminal implementation must display the out-of-context data         and the field updates as soon as convenient.)         The terminal implementation sends the GO-AHEAD, without further         action on the part of the terminal user, when an enabled         function key or a "form-complete" is entered.      Since the terminal user must take explicit action to return the      GO-AHEAD to the application, instances will occur when the user      has the GO-AHEAD but the application needs it to display a new      form.  (This is most likely to occur when the user enters anYasuda & Thompson                                              [Page 23]

RFC 1043              Data Entry Terminal - DODIIS         February 1988      INTERRUPT PROCESS.)  When it does occur, the application should      send an out-of-context-context message requesting the user to      enter a "form-complete".  If the user cooperates, the application      can ignore any associated form response and regain control of the      connection to display its form.      The line discipline described here is more rigorous than that      described for NVT in MIL-STD-1782.  These rules apply only when      operating in DET mode.  At other times, the descriptions contained      in MIL-STD-1782 apply.  This distinction is necessary to ensure      interoperability with non-DET implementations of TELNET.   Standard TELNET control functions      The TELNET control functions, ERASE CHARACTER and ERASE LINE, are      NOT required and should not be sent in DET mode.   Other implementation notes      a. The DODIIS DET conceptual model does not support character         editors or basic scrolling applications.      b. Implementors are cautioned that DET subcommand parameters         (e.g., facilities maps) may take on the value of the IAC         character and must be replicated if they are to be properly         interpreted.      c. Principle of Robustness:  "Be conservative in what you send; be         liberal in what you accept from others."Yasuda & Thompson                                              [Page 24]

RFC 1043              Data Entry Terminal - DODIIS         February 1988APPENDIX 1 - DET OPCODES AND SUBCOMMAND SYNTAX.             OPCODE    SUBCOMMAND SYNTAX             ------    -----------------              1     EDIT-FACILITIES <facility map>              2     ERASE-FACILITIES <facility map>              3     TRANSMIT-FACILITIES <facility map>              4     FORMAT-FACILITIES <facility map 1><facility map 2>              5     MOVE-CURSOR <x><y>             12     HOME-CURSOR             17     READ-CURSOR             18     CURSOR-POSITION <x><y>             20     TRANSMIT-SCREEN             21     TRANSMIT-UNPROTECTED             27     TRANSMIT-MODIFIED             28     DATA-TRANSMIT <x><y>             29     ERASE-SCREEN             35     ERASE-UNPROTECTED             36     FORMAT-DATA <format map><count>             37     REPEAT <count><character>             39     FIELD-SEPARATOR             40     FUNCTION-KEY <code>             41     ERROR <cmd><error code>             42     START-OUT-OF-CONTEXT-DATA             43     END-OUT-OF-CONTEXT-DATA             44     ENABLE-FUNCTION-KEYS <key-map>             45     SELECTED-FIELD <x><y>Yasuda & Thompson                                              [Page 25]

RFC 1043              Data Entry Terminal - DODIIS         February 1988APPENDIX 2 - DET ERROR CODES              1        Facility not previously negotiated.              2        Illegal subcommand code.              3        Cursor Address Out of Bounds.              4        Undefined FUNCTION-KEY value.              5        Can't negotiate acceptable line width.              6        Can't negotiate acceptable page length.              7        Illegal parameter in subcommand.              8        Syntax error in parsing subcommand.              9        Too many parameters in subcommand.             10        Too few parameters in subcommand.             11        Undefined parameter value.             12        Unsupported combination of Format Attributes.             13        Invalid field - overlap detected.Yasuda & Thompson                                              [Page 26]

[8]ページ先頭

©2009-2025 Movatter.jp