Gasoline and methanol exposures from automobiles within residences and attached garages

Technical Report·
OSTI ID:5882923
A pilot study was conducted to evaluate the characteristics of the air concentrations within a garage microenvironment. The air exchange rate between the garage and the house, the windspeed in front of the garage door, the fuel tank temperature, and the air concentrations of benzene (from gasoline) and methanol (from M100 fuel) were measured after an automobile containing US summer grade gasoline or a fabricated fuel tank containing M100 fuel entered the garage and its door was closed. The air concentrations in the garage were greatly elevated after the car or M100 fuel tank entered the garage compared to the ambient levels which were present prior to the car's entry. A steady state concentration was often reached within 90 minutes of the automobile or fuel tank entering the garage and the air concentration remained level until the fuel tank temperature returned to ambient levels, several hours later.
🛈
OSTI does not have a digital full text copy available.For more information, please seedocument availability, searchWorldCat, or searchGoogle Scholar.
Cite

Citation Formats

Weisel, C P, et al. "Gasoline and methanol exposures from automobiles within residences and attached garages." , Jan. 1993.
Weisel, C P, Lawryk, N J, Huber, A H, & Crescenti, G H (1993). Gasoline and methanol exposures from automobiles within residences and attached garages.
Weisel, C P, Lawryk, N J, Huber, A H, et al., "Gasoline and methanol exposures from automobiles within residences and attached garages," (1993)
@techreport{osti_5882923, author = {Weisel, C P and Lawryk, N J and Huber, A H and Crescenti, G H}, title = {Gasoline and methanol exposures from automobiles within residences and attached garages}, institution = {Environmental and Occupational Health Sciences Inst., Piscataway, NJ (United States). Exposure Measurement and Assessment Div.}, annote = {A pilot study was conducted to evaluate the characteristics of the air concentrations within a garage microenvironment. The air exchange rate between the garage and the house, the windspeed in front of the garage door, the fuel tank temperature, and the air concentrations of benzene (from gasoline) and methanol (from M100 fuel) were measured after an automobile containing US summer grade gasoline or a fabricated fuel tank containing M100 fuel entered the garage and its door was closed. The air concentrations in the garage were greatly elevated after the car or M100 fuel tank entered the garage compared to the ambient levels which were present prior to the car's entry. A steady state concentration was often reached within 90 minutes of the automobile or fuel tank entering the garage and the air concentration remained level until the fuel tank temperature returned to ambient levels, several hours later.}, url = {https://www.osti.gov/biblio/5882923}, place = {United States}, year = {1993}, month = {01}}
Save

You mustSign In orCreate an Account in order to save documents to your library.

Research Organization:
Environmental and Occupational Health Sciences Inst., Piscataway, NJ (United States). Exposure Measurement and Assessment Div.
OSTI ID:
5882923
Report Number(s):
PB-93-222222/XAB; CNN: EPA-CR82023501
Country of Publication:
United States
Language:
English

Similar Records

Exposure to emissions from gasoline within automobile cabins
Journal Article· Tue Dec 31 23:00:00 EST 1991· Journal of Esposure Analysis and Environmental Epidemiology; (United States)·OSTI ID:7078286

Vapor space flammability of automobile tanks containing low RVP gasolines
Conference· Sun Dec 31 23:00:00 EST 1989·OSTI ID:5880327

Characterization of emissions from a variable gasoline/methanol-fueled car
Technical Report· Sun Dec 31 23:00:00 EST 1989·OSTI ID:5897805

[8]ページ先頭

©2009-2026 Movatter.jp