CLCxSELn Registers

The CLCxSEL Registers, contained in theConfigurable Logic Cell (CLC), control which inputs are used with the CLC.


CLC Input Sources

The CLC will have multiple inputs to select from and each will have a 3 bit code associated with it, as shown in the table below. Each input can be connected to one of the two input data gates through a multiplexer that is controlled by the CLCxSEL0 and CLCxSEL1 registers.

CLCInputs.png

The Input Selections are controlled by the CLCxSEL0 and CLCxSEL1 registers by setting the input 3-bit code.

  • The CLCxSEL0 register controls the data input gates 1 and 2. Bits 0-2 control input 1 and bits 4-6 control the input 2.

CLCxSEL0: MULTIPLEXER DATA 1 AND 2 SELECT REGISTER

CLCSEL0.png

  • The CLCxSEL1 register controls the data input gates 3 and 4. Bits 0-2 control input 3 and bits 4-6 control the input 4.

CLCxSEL1: MULTIPLEXER DATA 3 AND 4 SELECT REGISTER

CLCSEL1.png