Device Power (CHB) Setup

The Device Power configuration is used in cases where only the microcontroller or a section of the target application is desired to be monitored.

Hardware Setup

Connecting the Channel B (CHB) Voltage Out (VO) terminal to the device or target section allows small current measurements to be made, typically in the range from μA to a few mA. The modular cable still needs to be connected to provide communication to the emulator.

Connecting the Channel B (CHB) Voltage In (VI) terminal to the target power supply section allows voltage measurements to be made.

PMON_CHB_Connections.jpg

Figure 1: Power Monitor Board CHB Connections

PMON_CHB_Internal.jpg

Figure 2: CHB Internal Connections

Software Setup – Power

In this configuration, you can continue powering the target from the emulator or you can power the target board independently.

  1. In theProject Properties window, click on theReal ICE category and select thePower option category.
  2. Locate the checkboxPower target circuit from REAL ICE. Check to power the target from the emulator. Uncheck to power the target with its own power supply.
  3. ClickApply orOK.

Power Monitor Usage

Regardless of which Power Data mode you are using, you need to change the type of power measurement:

  1. In theProject Properties window, click on theReal ICE category and select theTrace and Profiling option category.
  2. UnderPower Measurement, selectProcessor Only (1μA - 9mA).
  3. ClickOK.
ProcessorOnly.gif

Figure 3: Processor Only