Oneplug Power Monitoring Plug (UP111)

Available from:
Amazon.co.uk
Install method:
USB to Serial
GPIO # | Component |
---|---|
GPIO00 | Led_i 2 |
GPIO01 | None |
GPIO02 | None |
GPIO03 | None |
GPIO04 | HLWBL CF1 |
GPIO05 | BL0937 CF |
GPIO09 | None |
GPIO10 | None |
GPIO12 | HLWBL SELi |
GPIO13 | None |
GPIO14 | Relay 1 |
GPIO15 | None |
GPIO16 | Button 1 |
GPIO17 | None |
Configuration
{"NAME":"ONEPLUG UP111","GPIO":[321,0,0,0,2656,2720,0,0,2624,0,224,0,32,0],"FLAG":0,"BASE":18}
For more accurate energy consumption measurements this device requirespower monitoring calibration.
This looks like the “Gosund 13A Power Monitoring Plug (UP111)” but the template for that did not work and it would not Tuya-Convert. Had to use serial method.