PROPOSED STANDARD
Network Working Group                                    J. Quittek, Ed.Request for Comments: 4560                                           NECObsoletes:2925                                            K. White, Ed.Category: Standards Track                                      IBM Corp.                                                               June 2006Definitions of Managed Objectsfor Remote Ping, Traceroute, and Lookup OperationsStatus of This Memo   This document specifies an Internet standards track protocol for the   Internet community, and requests discussion and suggestions for   improvements.  Please refer to the current edition of the "Internet   Official Protocol Standards" (STD 1) for the standardization state   and status of this protocol.  Distribution of this memo is unlimited.Copyright Notice   Copyright (C) The Internet Society (2006).Abstract   This memo defines Management Information Bases (MIBs) for performing   ping, traceroute, and lookup operations at a host.  When managing a   network, it is useful to be able to initiate and retrieve the results   of ping or traceroute operations when they are performed at a remote   host.  A lookup capability is defined in order to enable resolution   of either an IP address to an DNS name or a DNS name to an IP address   at a remote host.   Currently, there are several enterprise-specific MIBs for performing   remote ping or traceroute operations.  The purpose of this memo is to   define a standards-based solution to enable interoperability.Quittek & White             Standards Track                     [Page 1]

RFC 4560                       REMOPS MIB                      June 2006Table of Contents1. Introduction ....................................................31.1. Ping .......................................................31.2. Traceroute .................................................41.3. Lookup .....................................................51.4. Remote Operations ..........................................52. The Internet-Standard Management Framework ......................53. Structure of the MIBs ...........................................63.1. Ping MIB ...................................................63.1.1. pingMaxConcurrentRequests ...........................73.1.2. pingCtlTable ........................................73.1.3. pingResultsTable ....................................73.1.4. pingProbeHistoryTable ...............................83.2. Traceroute MIB .............................................83.2.1. traceRouteMaxConcurrentRequests .....................83.2.2. traceRouteCtlTable ..................................83.2.3. traceRouteResultsTable ..............................93.2.4. traceRouteProbeHistoryTable ........................103.2.5. traceRouteHopsTable ................................103.3. Lookup MIB ................................................103.3.1. lookupMaxConcurrentRequests and lookupPurgeTime ....113.3.2. lookupCtlTable .....................................113.3.3. lookupResultsTable .................................123.4. Conformance ...............................................124. Definitions ....................................................134.1. DISMAN-PING-MIB ...........................................134.2. DISMAN-TRACEROUTE-MIB .....................................464.3. DISMAN-NSLOOKUP-MIB .......................................845. Security Considerations ........................................956. Acknowledgements ...............................................977. References .....................................................977.1. Normative References ......................................977.2. Informative References ....................................98Quittek & White             Standards Track                     [Page 2]

RFC 4560                       REMOPS MIB                      June 20061.  Introduction   This document defines standards-based MIB modules for performing   specific remote operations.  The remote operations defined by this   document consist of the ping, traceroute, and lookup functions.   Ping and traceroute are two very useful functions for managing   networks.  Ping is typically used to determine whether a path exists   between two hosts, whereas traceroute shows an actual path.   Both ping and traceroute yield round-trip times measured in   milliseconds.  These times can be used as a rough approximation for   network transit time.   The lookup functions considered in this document are the equivalents   of name to address conversion functions such as   gethostbyname()/gethostbyaddr() and getaddrinfo()/getnameinfo().   The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",   "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this   document are to be interpreted as described inRFC 2119 [RFC2119].1.1.  Ping   Ping is usually implemented using the Internet Control Message   Protocol (ICMP) "ECHO" facility.  It is also possible to implement a   ping capability using alternate methods, including the following:      o   Using the UDP echo port (7), if supported.          This is defined byRFC 862 [RFC862].      o   Timing a Simple Network Management Protocol (SNMP) query.      o   Timing a TCP connect attempt.   In general, almost any request/response flow can be used to generate   a round-trip time.  Often, many of the non-ICMP ECHO facility methods   stand a better chance of yielding a good response (not timing out,   for example) since some routers don't honor Echo Requests (timeout   situation) or are handled at lower priority, thus possibly giving   false indications of round trip times.Quittek & White             Standards Track                     [Page 3]

RFC 4560                       REMOPS MIB                      June 2006   Note that almost any of the various methods used for generating a   round-trip time can be considered a form of system attack when used   excessively.  Sending a system request too often can negatively   effect its performance.  Attempting to connect to what is supposed to   be an unused port can be very unpredictable.  There are tools that   attempt to connect to a range of TCP ports to test that any receiving   server can handle erroneous connection attempts.   It is also important to a management application using a remote ping   capability to know which method is being used.  Different methods   will yield different response times, since the protocol and resulting   processing will be different.  It is RECOMMENDED that the ping   capability defined within this memo be implemented using the ICMP   Echo Facility.1.2.  Traceroute   Traceroute is usually implemented by transmitting a series of probe   packets with increasing time-to-live values.  A probe packet is a UDP   datagram encapsulated into an IP packet.  Each hop in a path to the   target (destination) host rejects the probe packet (probe's TTL too   small) until its time-to-live value becomes large enough for the   probe to be forwarded.  Each hop in a traceroute path returns an ICMP   message that is used to discover the hop and to calculate a round   trip time.  Some systems use ICMP probes (ICMP Echo request packets)   instead of UDP ones to implement traceroute.  In both cases   traceroute relies on the probes being rejected via an ICMP message to   discover the hops taken along a path to the final destination.  Both   probe types, UDP and ICMP, are encapsulated into an IP packet and   thus have a TTL field that can be used to cause a path rejection.   Implementations of the remote traceroute capability as defined within   this memo SHOULD be done using UDP packets to a (hopefully) unused   port.  ICMP probes (ICMP Echo Request packets) SHOULD NOT be used.   Many PC implementations of traceroute use the ICMP probe method,   which they should not, since this implementation method has been   known to have a high probability of failure.  Intermediate hops   become invisible when a router either refuses to send an ICMP TTL   expired message in response to an incoming ICMP packet or simply   tosses ICMP echo requests altogether.   The behavior of some routers not to return a TTL expired message in   response to an ICMP Echo request is due in part to the following text   extracted fromRFC 792 [RFC792]:   "The ICMP messages typically report errors in the processing of   datagrams.  To avoid the infinite regress of messages about messages   etc., no ICMP messages are sent about ICMP messages."Quittek & White             Standards Track                     [Page 4]

RFC 4560                       REMOPS MIB                      June 20061.3.  Lookup   The Lookup operation enables remote lookup of addresses for a   symbolic name as it is, for example, performed by functions   getnameinfo() or gethostbyaddr() and lookup of symbolic names for an   address as it is, for example, performed by functions getaddrinfo()   or gethostbyname().  Note that whatever lookup function is chosen,   results are not necessarily consistent with the results of a pure   Domain Name Service (DNS) lookup, but may be influenced by local   lookup tables or other sources of information.  The lookup capability   can be used to determine the symbolic name of a hop in a traceroute   path.  Also, the reverse lookup can be used, for example, for   analyzing name lookup problems.1.4.  Remote Operations   The MIB modules defined in this document allow a management station   to initiate ping, traceroute, and lookup operations remotely.  The   basic scenario is illustrated by the following diagram.         +-------+           +-------+           +-------+         |       |---------->|       |           |       |         |       | initiate  |       |---------->|       |         | Mgmt. | operation |Managed|  perform  |Target |         |Station| remotely  | Node  | operation | Host  |         |       |           |       |           |       |         |       |<----------|       |           |       |         +-------+  receive  +-------+           +-------+                   result of                   operation   A management station is the local host from which the remote ping,   traceroute, or Lookup operation is initiated using an SNMP request.   The managed node is a remote host where the MIBs defined by this memo   are implemented.  It receives the remote operation via SNMP and   performs the actual ping, traceroute, or lookup function.2.  The Internet-Standard Management Framework   For a detailed overview of the documents that describe the current   Internet-Standard Management Framework, please refer tosection 7 of   RFC 3410 [RFC3410].Quittek & White             Standards Track                     [Page 5]

RFC 4560                       REMOPS MIB                      June 2006   Managed objects are accessed via a virtual information store, termed   the Management Information Base or MIB.  MIB objects are generally   accessed through the Simple Network Management Protocol (SNMP).   Objects in the MIB are defined using the mechanisms defined in the   Structure of Management Information (SMI).  This memo specifies a MIB   module that is compliant to the SMIv2, which is described in STD 58,RFC 2578 [RFC2578], STD 58,RFC 2579 [RFC2579] and STD 58,RFC 2580   [RFC2580].3.  Structure of the MIBs   This document defines three MIB modules:      o   DISMAN-PING-MIB          Defines a ping MIB.      o   DISMAN-TRACEROUTE-MIB          Defines a traceroute MIB.      o   DISMAN-NSLOOKUP-MIB   Provides access to lookup functions for symbolic names and addresses   at a remote host provided, for example, by functions   getaddrinfo()/getnameinfo() and gethostbyname()/gethostbyaddr().   The ping and traceroute MIBs are structured to allow creation of ping   or traceroute tests that can be set up to issue a series of   operations periodically and to generate NOTIFICATIONs to report on   test results.  Many network administrators have in the past written   UNIX shell scripts or command batch files to operate in a fashion   similar to the functionality provided by the ping and traceroute MIBs   defined within this memo.  The intent of this document is to   acknowledge the importance of these functions and to provide a   standards-based solution.3.1.  Ping MIB   The DISMAN-PING-MIB consists of the following components:      o   pingMaxConcurrentRequests      o   pingCtlTable      o   pingResultsTable      o   pingProbeHistoryTableQuittek & White             Standards Track                     [Page 6]

RFC 4560                       REMOPS MIB                      June 20063.1.1.  pingMaxConcurrentRequests   The object pingMaxConcurrentRequests enables control of the maximum   number of concurrent active requests that an agent implementation   supports.  It is permissible for an agent either to limit the maximum   upper range allowed for this object or to implement this object as   read-only with an implementation limit expressed as its value.3.1.2.  pingCtlTable   A remote ping test is started by setting pingCtlAdminStatus to   enabled(1).  The corresponding pingCtlEntry MUST have been created,   and its pingCtlRowStatus set to active(1), prior to starting the   test.  A single SNMP PDU can be used to create and start a remote   ping test.  Within the PDU, pingCtlTargetAddress should be set to the   target host's address (pingCtlTargetAddressType will default to   ipv4(1)), pingCtlAdminStatus to enabled(1), and pingCtlRowStatus to   createAndGo(4).   The first index element, pingCtlOwnerIndex, is of type   SnmpAdminString, a textual convention that allows for use of the   SNMPv3 View-Based Access Control Model (RFC 3415 [RFC3415], VACM) and   that allows a management application to identify its entries.  The   second index, pingCtlTestName (also an SnmpAdminString), enables the   same management application to have multiple requests outstanding.   Using the maximum value for the parameters defined within a pingEntry   can result in a single remote ping test's taking at most 15 minutes   (pingCtlTimeOut times pingCtlProbeCount), plus whatever time it takes   to send the ping request and to receive its response over the network   from the target host.  Use of the defaults for pingCtlTimeOut and   pingCtlProbeCount yields a maximum of 3 seconds to perform a "normal"   ping test.   A management application can delete an active remote ping request by   setting the corresponding pingCtlRowStatus object to destroy(6).   The contents of the pingCtlTable are preserved across reIPLs (Initial   Program Loads) of its agent according the values of each of the   pingCtlStorageType objects.3.1.3.  pingResultsTable   An entry in the pingResultsTable is created for a corresponding   pingCtlEntry once the test defined by this entry is started.Quittek & White             Standards Track                     [Page 7]

RFC 4560                       REMOPS MIB                      June 20063.1.4.  pingProbeHistoryTable   The results of past ping probes are stored in this table on a per-   pingCtlEntry basis.  This table is initially indexed by   pingCtlOwnerIndex and pingCtlTestName so that the results of a probe   relate to the pingCtlEntry that caused it.  The maximum number of   entries stored in this table per pingCtlEntry is determined by the   value of pingCtlMaxRows.   An implementation of this MIB will remove the oldest entry in the   pingProbeHistoryTable of the corresponding entry in the pingCtlTable   to allow the addition of a new entry once the number of rows in the   pingProbeHistoryTable reaches the value specified by pingCtlMaxRows   for the corresponding entry in the pingCtlTable.  An implementation   MUST start assigning pingProbeHistoryIndex values at 1 and wrap after   exceeding the maximum possible value, as defined by the limit of this   object ('ffffffff'h).3.2.  Traceroute MIB   The DISMAN-TRACEROUTE-MIB consists of the following components:      o   traceRouteMaxConcurrentRequests      o   traceRouteCtlTable      o   traceRouteResultsTable      o   traceRouteProbeHistoryTable      o   traceRouteHopsTable3.2.1.  traceRouteMaxConcurrentRequests   The object traceRouteMaxConcurrentRequests enables control of the   maximum number of concurrent active requests that an agent   implementation supports.  It is permissible for an agent either to   limit the maximum upper range allowed for this object or to implement   this object as read-only with an implementation limit expressed as   its value.3.2.2.  traceRouteCtlTable   A remote traceroute test is started by setting   traceRouteCtlAdminStatus to enabled(1).  The corresponding   traceRouteCtlEntry MUST have been created, and its   traceRouteCtlRowStatus set to active(1), prior to starting the test.   A single SNMP PDU can be used to create and start a remote tracerouteQuittek & White             Standards Track                     [Page 8]

RFC 4560                       REMOPS MIB                      June 2006   test.  Within the PDU, traceRouteCtlTargetAddress should be set to   the target host's address (traceRouteCtlTargetAddressType will   default to ipv4(1)), traceRouteCtlAdminStatus to enabled(1), and   traceRouteCtlRowStatus to createAndGo(4).   The first index element, traceRouteCtlOwnerIndex, is of type   SnmpAdminString, a textual convention that allows for use of the   SNMPv3 View-Based Access Control Model (RFC 3415 [RFC3415], VACM) and   that allows a management application to identify its entries.  The   second index, traceRouteCtlTestName (also an SnmpAdminString),   enables the same management application to have multiple requests   outstanding.   Traceroute has a much longer theoretical maximum time for completion   than ping: basically, 42 hours and 30 minutes (the product of   traceRouteCtlTimeOut, traceRouteCtlProbesPerHop, and   traceRouteCtlMaxTtl) plus some network transit time!  Use of the   defaults defined within an traceRouteCtlEntry yields a maximum of 4   minutes and 30 seconds for a default traceroute operation.  Clearly,   42 plus hours is too long to wait for a traceroute operation to be   completed.   The maximum Time to Live (TTL) value in effect for traceroute   determines how long the traceroute function will keep increasing the   TTL value in the probe it transmits, hoping to reach the target host.   The function ends whenever the maximum TTL is exceeded or the target   host is reached.  The object traceRouteCtlMaxFailures was created in   order to impose a throttle for how long traceroute continues to   increase the TTL field in a probe without receiving any kind of   response (timeouts).  It is RECOMMENDED that agent implementations   impose a time limit for how long it allows a traceroute operation to   take, relative to how the function is implemented.  For example, an   implementation that can't process multiple traceroute operations at   the same time SHOULD impose a shorter maximum allowed time period.   A management application can delete an active remote traceroute   request by setting the corresponding traceRouteCtlRowStatus object to   destroy(6).   The contents of the traceRouteCtlTable are preserved across reIPLs   (Initial Program Loads) of its agent according to the values of each   of the traceRouteCtlStorageType objects.3.2.3.  traceRouteResultsTable   An entry in the traceRouteResultsTable is created upon determining   the results of a specific traceroute operation.  Entries in this   table relate back to the traceRouteCtlEntry that caused theQuittek & White             Standards Track                     [Page 9]

RFC 4560                       REMOPS MIB                      June 2006   corresponding traceroute operation to occur.  The objects   traceRouteResultsCurHopCount and traceRouteResultsCurProbeCount can   be examined to determine how far the current remote traceroute   operation has reached.3.2.4.  traceRouteProbeHistoryTable   The results of past traceroute probes can be stored in this table on   a per-traceRouteCtlEntry basis.  This table is initially indexed by   traceRouteCtlOwnerIndex and traceRouteCtlTestName so that the results   of a probe relate to the traceRouteCtlEntry that caused it.  The   number of entries stored in this table per traceRouteCtlEntry is   determined by the value of traceRouteCtlMaxRows.   An implementation of this MIB will remove the oldest entry in the   traceRouteProbeHistoryTable of the corresponding entry in the   traceRouteCtlTable to allow the addition of an new entry once the   number of rows in the traceRouteProbeHistoryTable reaches the value   of traceRouteCtlMaxRows for the corresponding entry in the   traceRouteCtlTable.  An implementation MUST start assigning   traceRouteProbeHistoryIndex values at 1 and wrap after exceeding the   maximum possible value, as defined by the limit of this object   ('ffffffff'h).3.2.5.  traceRouteHopsTable   The current traceroute path can be stored in this table on a per-   traceRouteCtlEntry basis.  This table is initially indexed by   traceRouteCtlOwnerIndex and traceRouteCtlTestName so that a   traceroute path relates to the traceRouteCtlEntry that caused it.  A   third index, traceRouteHopsHopIndex, enables keeping one   traceRouteHopsEntry per traceroute hop.  Creation of   traceRouteHopsTable entries is enabled by setting the corresponding   traceRouteCtlCreateHopsEntries object to true(1).3.3.  Lookup MIB   The DISMAN-NSLOOKUP-MIB consists of the following components:      o   lookupMaxConcurrentRequests and lookupPurgeTime      o   lookupCtlTable      o   lookupResultsTableQuittek & White             Standards Track                    [Page 10]

RFC 4560                       REMOPS MIB                      June 20063.3.1.  lookupMaxConcurrentRequests and lookupPurgeTime   The object lookupMaxConcurrentRequests enables control of the maximum   number of concurrent active requests that an agent implementation is   structured to support.  It is permissible for an agent either to   limit the maximum upper range allowed for this object or to implement   this object as read-only with an implementation limit expressed as   its value.   The object lookupPurgeTime provides a method for entries in the   lookupCtlTable and lookupResultsTable to be automatically deleted   after the corresponding operation is completed.3.3.2.  lookupCtlTable   A remote lookup operation is initiated by performing an SNMP SET   request on lookupCtlRowStatus.  A single SNMP PDU can be used to   create and start a remote lookup operation.  Within the PDU,   lookupCtlTargetAddress should be set to the entity to be resolved   (lookupCtlTargetAddressType will default to ipv4(1)) and   lookupCtlRowStatus to createAndGo(4).  The object lookupCtlOperStatus   can be examined to determine the state of a lookup operation.  A   management application can delete an active remote lookup request by   setting the corresponding lookupCtlRowStatus object to destroy(6).   An lookupCtlEntry is initially indexed by lookupCtlOwnerIndex, which   is a type of SnmpAdminString, a textual convention that allows for   use of the SNMPv3 View-Based Access Control Model (RFC 3415   [RFC3415],   VACM) and that also allows for a management application to identify   its entries.  The lookupCtlOwnerIndex portion of the index is then   followed by lookupCtlOperationName.  The lookupCtlOperationName index   enables the same lookupCtlOwnerIndex entity to have multiple   outstanding requests.   The value of lookupCtlTargetAddressType determines which lookup   function to perform.  Specification of dns(16) as the value of this   index implies that a function such as getaddrinfo() or   gethostbyname() should be performed to determine the numeric   addresses associated with a symbolic name via lookupResultsTable   entries.  Use of a value of either ipv4(1) or ipv6(2) implies that a   function such as getnameinfo() or gethostbyaddr() should be performed   to determine the symbolic name(s) associated with a numeric address   at a remote host.Quittek & White             Standards Track                    [Page 11]

RFC 4560                       REMOPS MIB                      June 20063.3.3.  lookupResultsTable   The lookupResultsTable is used to store the results of lookup   operations.  Results to be reported here SHOULD be results of a   lookup function that is commonly used by applications at the managed   node.  This implies that results are not necessarily consistent with   the results of a pure DNS lookup at the managed node, but may be   influenced by local lookup tables or other sources of information,   depending on the configuration of the managed node.   The lookupResultsTable is initially indexed by the same index   elements that the lookupCtlTable contains (lookupCtlOwnerIndex and   lookupCtlOperationName) but has a third index element,   lookupResultsIndex (Unsigned32 textual convention), in order to   associate multiple results with the same lookupCtlEntry.   A remote host can be multi-homed and can have multiple symbolic (DNS)   names.  Therefore, a lookup operation can return multiple IP   addresses and multiple symbolic names.   If the lookup operation was performed for a certain address by using   getnameinfo() or gethostbyaddr(), for example, then entries in the   lookupResultsTable MUST be made for each host name returned.  If the   lookup operation identifies one hostname as the host's 'official host   name', then this name MUST be assigned a lookupResultsIndex of 1.   If a lookup operation was performed for a certain symbolic name by   using getaddrinfo() or gethostbyname(), for example, then entries in   the lookupResultsTable MUST be made for each address returned.  The   entries MUST be stored in the order that they are retrieved.  Values   assigned to lookupResultsIndex MUST start at 1 and increase in order.   An implementation SHOULD NOT retain SNMP-created entries in the   lookupResultsTable across reIPLs (Initial Program Loads) of its   agent, since management applications need to see consistent behavior   with respect to the persistence of the table entries that they   create.3.4.  Conformance   Each of the three MIB modules defined in this document has two   current compliance statements, one for full compliance and one for   minimum compliance.  The minimum compliance statements are intended   to be applied to implementation for devices with very limited   resources.  The main difference between full and minimum compliance   is that for minimum compliance, dynamic creation and deletion of   table entries is not required, whereas it is required for full   compliance.Quittek & White             Standards Track                    [Page 12]

RFC 4560                       REMOPS MIB                      June 2006   In addition, the DISMAN-PING-MIB module and the DISMAN-TRACEROUTE-MIB   modules each have a deprecated compliance statement that was current   inRFC 2925.  Semantically, the new full compliance statements are   identical to the deprecated ones.  But some of the object groups used   in the old compliance statements needed to be split in order to   support the new minimal compliance statements.4.  Definitions   The following MIB modules import from [RFC2863], [RFC3411], and   [RFC4001].  They also use the REFERENCE clause to reference   [RFC1812], [RFC2474], and [RFC3260].4.1.  DISMAN-PING-MIB   DISMAN-PING-MIB DEFINITIONS ::= BEGIN   IMPORTS       MODULE-IDENTITY, OBJECT-TYPE, Integer32,       Unsigned32, Gauge32, mib-2,       NOTIFICATION-TYPE, OBJECT-IDENTITY           FROM SNMPv2-SMI                  --RFC2578       TEXTUAL-CONVENTION, RowStatus,       StorageType, DateAndTime, TruthValue           FROM SNMPv2-TC                   --RFC2579       MODULE-COMPLIANCE, OBJECT-GROUP,       NOTIFICATION-GROUP           FROM SNMPv2-CONF                 --RFC2580       InterfaceIndexOrZero                 --RFC2863           FROM IF-MIB       SnmpAdminString           FROM SNMP-FRAMEWORK-MIB          --RFC3411       InetAddressType, InetAddress           FROM INET-ADDRESS-MIB;           --RFC4001    pingMIB MODULE-IDENTITY       LAST-UPDATED "200606130000Z"         -- 13 June 2006       ORGANIZATION "IETF Distributed Management Working Group"       CONTACT-INFO           "Juergen Quittek           NEC Europe Ltd.           Network Laboratories           Kurfuersten-Anlage 36           69115 Heidelberg           Germany           Phone: +49 6221 4342-115Quittek & White             Standards Track                    [Page 13]

RFC 4560                       REMOPS MIB                      June 2006           Email: quittek@netlab.nec.de"       DESCRIPTION           "The Ping MIB (DISMAN-PING-MIB) provides the capability of           controlling the use of the ping function at a remote           host.           Copyright (C) The Internet Society (2006).  This version of           this MIB module is part ofRFC 4560; see the RFC itself for           full legal notices."        --  Revision history        REVISION     "200606130000Z"         -- 13 June 2006        DESCRIPTION            "Updated version, published asRFC 4560.                - Correctly considered IPv6 in DESCRIPTION                  clause of pingCtlDataSize                - Replaced references toRFC 2575 byRFC 3415                - Replaced references toRFC 2571 byRFC 3411                - Replaced references toRFC 2851 byRFC 4001                - Added DEFVAL { {} } to definition of                  pingCtlTrapGeneration                - Changed DEFVAL of object pingCtlDescr from                  DEFVAL { '00'H } to DEFVAL { ''H }                - Changed DEFVAL of object pingCtlSourceAddressType                  from DEFVAL { ipv4 } to DEFVAL { unknown }                - Extended DESCRIPTION clause of pingResultsTable                  describing re-initialization of entries                - Changed SYNTAX of pingResultsProbeResponses and                  pingResultsSentProbes from Unsigned32 to Gauge32                - Changed status of pingCompliance to deprecated                - Added pingFullCompliance and pingMinimumCompliance                - Changed status of pingGroup and pingTimeStampGroup                  to deprecated                - Added pingMinimumGroup, pingCtlRowStatusGroup,                  and pingHistoryGroup"        REVISION     "200009210000Z"         -- 21 September 2000        DESCRIPTION            "Initial version, published asRFC 2925."       ::= { mib-2 80 }    -- Textual Conventions     OperationResponseStatus ::= TEXTUAL-CONVENTION       STATUS  current       DESCRIPTIONQuittek & White             Standards Track                    [Page 14]

RFC 4560                       REMOPS MIB                      June 2006           "Used to report the result of an operation:            responseReceived(1) - Operation is completed successfully.            unknown(2) - Operation failed due to unknown error.            internalError(3) - An implementation detected an error                 in its own processing that caused an operation                 to fail.            requestTimedOut(4) - Operation failed to receive a                 valid reply within the time limit imposed on it.            unknownDestinationAddress(5) - Invalid destination                 address.            noRouteToTarget(6) - Could not find a route to target.            interfaceInactiveToTarget(7) - The interface to be                 used in sending a probe is inactive, and an                 alternate route does not exist.            arpFailure(8) - Unable to resolve a target address to a                 media-specific address.            maxConcurrentLimitReached(9) - The maximum number of                 concurrent active operations would have been exceeded                 if the corresponding operation was allowed.            unableToResolveDnsName(10) - The DNS name specified was                 unable to be mapped to an IP address.            invalidHostAddress(11) - The IP address for a host                 has been determined to be invalid.  Examples of this                 are broadcast or multicast addresses."       SYNTAX INTEGER {                    responseReceived(1),                    unknown(2),                    internalError(3),                    requestTimedOut(4),                    unknownDestinationAddress(5),                    noRouteToTarget(6),                    interfaceInactiveToTarget(7),                    arpFailure(8),                    maxConcurrentLimitReached(9),                    unableToResolveDnsName(10),                    invalidHostAddress(11)                 }    -- Top level structure of the MIB    pingNotifications              OBJECT IDENTIFIER ::= { pingMIB 0 }    pingObjects                    OBJECT IDENTIFIER ::= { pingMIB 1 }    pingConformance                OBJECT IDENTIFIER ::= { pingMIB 2 }    -- The registration node (point) for ping implementation typesQuittek & White             Standards Track                    [Page 15]

RFC 4560                       REMOPS MIB                      June 2006    pingImplementationTypeDomains  OBJECT IDENTIFIER ::= { pingMIB 3 }    pingIcmpEcho OBJECT-IDENTITY       STATUS      current       DESCRIPTION           "Indicates that an implementation is using the Internet           Control Message Protocol (ICMP) 'ECHO' facility."       ::= { pingImplementationTypeDomains 1 }    pingUdpEcho OBJECT-IDENTITY       STATUS      current       DESCRIPTION           "Indicates that an implementation is using the UDP echo           port (7)."       REFERENCE           "RFC 862, 'Echo Protocol'."       ::= { pingImplementationTypeDomains 2 }    pingSnmpQuery OBJECT-IDENTITY       STATUS      current       DESCRIPTION           "Indicates that an implementation is using an SNMP query            to calculate a round trip time."       ::= { pingImplementationTypeDomains 3 }    pingTcpConnectionAttempt OBJECT-IDENTITY       STATUS      current       DESCRIPTION           "Indicates that an implementation is attempting to           connect to a TCP port in order to calculate a round           trip time."       ::= { pingImplementationTypeDomains 4 }    -- Simple Object Definitions    pingMaxConcurrentRequests OBJECT-TYPE       SYNTAX      Unsigned32       UNITS       "requests"       MAX-ACCESS  read-write       STATUS      current       DESCRIPTION          "The maximum number of concurrent active ping requests          that are allowed within an agent implementation.  A value          of 0 for this object implies that there is no limit for          the number of concurrent active requests in effect.Quittek & White             Standards Track                    [Page 16]

RFC 4560                       REMOPS MIB                      June 2006          The limit applies only to new requests being activated.          When a new value is set, the agent will continue processing          all the requests already active, even if their number          exceeds the limit just imposed."       DEFVAL { 10 }       ::= { pingObjects 1 }    -- Ping Control Table    pingCtlTable OBJECT-TYPE       SYNTAX      SEQUENCE OF PingCtlEntry       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION           "Defines the ping Control Table for providing, via SNMP,           the capability of performing ping operations at           a remote host.  The results of these operations are           stored in the pingResultsTable and the           pingProbeHistoryTable."      ::= { pingObjects 2 }    pingCtlEntry OBJECT-TYPE       SYNTAX      PingCtlEntry       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION           "Defines an entry in the pingCtlTable.  The first index           element, pingCtlOwnerIndex, is of type SnmpAdminString,           a textual convention that allows for use of the SNMPv3           View-Based Access Control Model (RFC 3415, VACM)           and that allows a management application to identify its           entries.  The second index, pingCtlTestName (also an           SnmpAdminString), enables the same management           application to have multiple outstanding requests."       INDEX {                pingCtlOwnerIndex,                pingCtlTestName             }       ::= { pingCtlTable 1 }    PingCtlEntry ::=       SEQUENCE {           pingCtlOwnerIndex             SnmpAdminString,           pingCtlTestName               SnmpAdminString,           pingCtlTargetAddressType      InetAddressType,           pingCtlTargetAddress          InetAddress,           pingCtlDataSize               Unsigned32,           pingCtlTimeOut                Unsigned32,Quittek & White             Standards Track                    [Page 17]

RFC 4560                       REMOPS MIB                      June 2006           pingCtlProbeCount             Unsigned32,           pingCtlAdminStatus            INTEGER,           pingCtlDataFill               OCTET STRING,           pingCtlFrequency              Unsigned32,           pingCtlMaxRows                Unsigned32,           pingCtlStorageType            StorageType,           pingCtlTrapGeneration         BITS,           pingCtlTrapProbeFailureFilter Unsigned32,           pingCtlTrapTestFailureFilter  Unsigned32,           pingCtlType                   OBJECT IDENTIFIER,           pingCtlDescr                  SnmpAdminString,           pingCtlSourceAddressType      InetAddressType,           pingCtlSourceAddress          InetAddress,           pingCtlIfIndex                InterfaceIndexOrZero,           pingCtlByPassRouteTable       TruthValue,           pingCtlDSField                Unsigned32,           pingCtlRowStatus              RowStatus       }    pingCtlOwnerIndex OBJECT-TYPE       SYNTAX      SnmpAdminString (SIZE(0..32))       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION          "To facilitate the provisioning of access control by a          security administrator using the View-Based Access          Control Model (RFC 2575, VACM) for tables in which          multiple users may need to create or          modify entries independently, the initial index is used          as an 'owner index'.  Such an initial index has a syntax          of SnmpAdminString and can thus be trivially mapped to a          securityName or groupName defined in VACM, in          accordance with a security policy.          When used in conjunction with such a security policy, all          entries in the table belonging to a particular user (or          group) will have the same value for this initial index.          For a given user's entries in a particular table, the          object identifiers for the information in these entries          will have the same subidentifiers (except for the 'column'          subidentifier) up to the end of the encoded owner index.          To configure VACM to permit access to this portion of the          table, one would create vacmViewTreeFamilyTable entries          with the value of vacmViewTreeFamilySubtree including          the owner index portion, and vacmViewTreeFamilyMask          'wildcarding' the column subidentifier.  More elaborate          configurations are possible."       ::= { pingCtlEntry 1 }Quittek & White             Standards Track                    [Page 18]

RFC 4560                       REMOPS MIB                      June 2006    pingCtlTestName OBJECT-TYPE       SYNTAX      SnmpAdminString (SIZE(0..32))       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION           "The name of the ping test.  This is locally unique, within           the scope of a pingCtlOwnerIndex."       ::= { pingCtlEntry 2 }    pingCtlTargetAddressType OBJECT-TYPE       SYNTAX      InetAddressType       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "Specifies the type of host address to be used at a remote           host for performing a ping operation."       DEFVAL { unknown }       ::= { pingCtlEntry 3 }    pingCtlTargetAddress OBJECT-TYPE       SYNTAX      InetAddress       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "Specifies the host address to be used at a remote host for           performing a ping operation.  The host address type is           determined by the value of the corresponding           pingCtlTargetAddressType.           A value for this object MUST be set prior to transitioning           its corresponding pingCtlEntry to active(1) via           pingCtlRowStatus."       DEFVAL { ''H }       ::= { pingCtlEntry 4 }    pingCtlDataSize OBJECT-TYPE       SYNTAX      Unsigned32 (0..65507)       UNITS       "octets"       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "Specifies the size of the data portion to be           transmitted in a ping operation, in octets.  Whether this           value can be applied depends on the selected           implementation method for performing a ping operation,           indicated by pingCtlType in the same conceptual row.           If the method used allows applying the value containedQuittek & White             Standards Track                    [Page 19]

RFC 4560                       REMOPS MIB                      June 2006           in this object, then it MUST be applied.  If the specified           size is not appropriate for the chosen ping method, the           implementation SHOULD use whatever size (appropriate to           the method) is closest to the specified size.           The maximum value for this object was computed by           subtracting the smallest possible IP header size of           20 octets (IPv4 header with no options) and the UDP           header size of 8 octets from the maximum IP packet size.           An IP packet has a maximum size of 65535 octets           (excluding IPv6 Jumbograms)."       DEFVAL { 0 }       ::= { pingCtlEntry 5 }    pingCtlTimeOut OBJECT-TYPE       SYNTAX      Unsigned32 (1..60)       UNITS       "seconds"       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "Specifies the time-out value, in seconds, for a           remote ping operation."       DEFVAL { 3 }       ::= { pingCtlEntry 6 }    pingCtlProbeCount OBJECT-TYPE       SYNTAX      Unsigned32 (1..15)       UNITS       "probes"       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "Specifies the number of times to perform a ping           operation at a remote host as part of a single ping test."       DEFVAL { 1 }       ::= { pingCtlEntry 7 }    pingCtlAdminStatus OBJECT-TYPE       SYNTAX      INTEGER {                             enabled(1), -- test should be started                             disabled(2) -- test should be stopped                           }       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "Reflects the desired state that a pingCtlEntry should be           in:Quittek & White             Standards Track                    [Page 20]

RFC 4560                       REMOPS MIB                      June 2006              enabled(1)  - Attempt to activate the test as defined by                            this pingCtlEntry.              disabled(2) - Deactivate the test as defined by this                            pingCtlEntry.           Refer to the corresponding pingResultsOperStatus to           determine the operational state of the test defined by           this entry."        DEFVAL { disabled }       ::= { pingCtlEntry 8 }    pingCtlDataFill  OBJECT-TYPE       SYNTAX      OCTET STRING (SIZE(0..1024))       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "The content of this object is used together with the           corresponding pingCtlDataSize value to determine how to           fill the data portion of a probe packet.  The option of           selecting a data fill pattern can be useful when links           are compressed or have data pattern sensitivities.  The           contents of pingCtlDataFill should be repeated in a ping           packet when the size of the data portion of the ping           packet is greater than the size of pingCtlDataFill."       DEFVAL { '00'H }       ::= { pingCtlEntry 9 }    pingCtlFrequency  OBJECT-TYPE       SYNTAX      Unsigned32       UNITS       "seconds"       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "The number of seconds to wait before repeating a ping test           as defined by the value of the various objects in the           corresponding row.           A single ping test consists of a series of ping probes.           The number of probes is determined by the value of the           corresponding pingCtlProbeCount object.  After a single           test is completed the number of seconds as defined by the           value of pingCtlFrequency MUST elapse before the           next ping test is started.           A value of 0 for this object implies that the test           as defined by the corresponding entry will not be           repeated."       DEFVAL { 0 }Quittek & White             Standards Track                    [Page 21]

RFC 4560                       REMOPS MIB                      June 2006       ::= { pingCtlEntry 10 }    pingCtlMaxRows OBJECT-TYPE       SYNTAX      Unsigned32       UNITS       "rows"       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "The maximum number of corresponding entries allowed           in the pingProbeHistoryTable.  An implementation of this           MIB will remove the oldest corresponding entry in the           pingProbeHistoryTable to allow the addition of an           new entry once the number of corresponding rows in the           pingProbeHistoryTable reaches this value.           Old entries are not removed when a new test is           started.  Entries are added to the pingProbeHistoryTable           until pingCtlMaxRows is reached before entries begin to           be removed.           A value of 0 for this object disables creation of           pingProbeHistoryTable entries."       DEFVAL      { 50 }       ::= { pingCtlEntry 11 }    pingCtlStorageType OBJECT-TYPE       SYNTAX      StorageType       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "The storage type for this conceptual row.           Conceptual rows having the value 'permanent' need not           allow write-access to any columnar objects in the row."       DEFVAL { nonVolatile }       ::= { pingCtlEntry 12 }    pingCtlTrapGeneration OBJECT-TYPE       SYNTAX      BITS {                      probeFailure(0),                      testFailure(1),                      testCompletion(2)                     }       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "The value of this object determines when and whether           to generate a notification for this entry:Quittek & White             Standards Track                    [Page 22]

RFC 4560                       REMOPS MIB                      June 2006           probeFailure(0)   - Generate a pingProbeFailed               notification subject to the value of               pingCtlTrapProbeFailureFilter.  The object               pingCtlTrapProbeFailureFilter can be used               to specify the number of consecutive probe               failures that are required before a               pingProbeFailed notification can be generated.           testFailure(1)    - Generate a pingTestFailed               notification.  In this instance the object               pingCtlTrapTestFailureFilter can be used to               determine the number of probe failures that               signal when a test fails.           testCompletion(2) - Generate a pingTestCompleted               notification.           By default, no bits are set, indicating that           none of the above options is selected."       DEFVAL { {} }  -- no bits set.       ::= { pingCtlEntry 13 }    pingCtlTrapProbeFailureFilter OBJECT-TYPE       SYNTAX      Unsigned32 (0..15)       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "The value of this object is used to determine when           to generate a pingProbeFailed NOTIFICATION.           Setting BIT probeFailure(0) of object           pingCtlTrapGeneration to '1' implies that a           pingProbeFailed NOTIFICATION is generated only when           a number of consecutive ping probes equal to the           value of pingCtlTrapProbeFailureFilter fail within           a given ping test.  After triggering the notification,           the probe failure counter is reset to zero."       DEFVAL { 1 }       ::= { pingCtlEntry 14 }    pingCtlTrapTestFailureFilter OBJECT-TYPE       SYNTAX      Unsigned32 (0..15)       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "The value of this object is used to determine when           to generate a pingTestFailed NOTIFICATION.           Setting BIT testFailure(1) of objectQuittek & White             Standards Track                    [Page 23]

RFC 4560                       REMOPS MIB                      June 2006           pingCtlTrapGeneration to '1' implies that a           pingTestFailed NOTIFICATION is generated only when           a number of consecutive ping tests equal to the           value of pingCtlTrapProbeFailureFilter fail.           After triggering the notification, the test failure           counter is reset to zero."       DEFVAL { 1 }       ::= { pingCtlEntry 15 }    pingCtlType OBJECT-TYPE       SYNTAX      OBJECT IDENTIFIER       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "The value of this object is used either to report or           to select the implementation method to be used for           calculating a ping response time.  The value of this           object MAY be selected from pingImplementationTypeDomains.           Additional implementation types SHOULD be allocated as           required by implementers of the DISMAN-PING-MIB under           their enterprise-specific registration point and not           beneath pingImplementationTypeDomains."       DEFVAL { pingIcmpEcho }       ::= { pingCtlEntry 16 }    pingCtlDescr OBJECT-TYPE       SYNTAX      SnmpAdminString       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "The purpose of this object is to provide a           descriptive name of the remote ping test."       DEFVAL { ''H }       ::= { pingCtlEntry 17 }    pingCtlSourceAddressType OBJECT-TYPE       SYNTAX      InetAddressType       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "Specifies the type of the source address,           pingCtlSourceAddress, to be used at a remote host           when a ping operation is performed."       DEFVAL { unknown }       ::= { pingCtlEntry 18 }Quittek & White             Standards Track                    [Page 24]

RFC 4560                       REMOPS MIB                      June 2006     pingCtlSourceAddress OBJECT-TYPE       SYNTAX      InetAddress       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "Use the specified IP address (which must be given in           numeric form, not as a hostname) as the source address           in outgoing probe packets.  On hosts with more than one           IP address, this option can be used to select the address           to be used.  If the IP address is not one of this           machine's interface addresses, an error is returned and           nothing is sent.  A zero-length octet string value for           this object disables source address specification.           The address type (InetAddressType) that relates to           this object is specified by the corresponding value           of pingCtlSourceAddressType."       DEFVAL { ''H }       ::= { pingCtlEntry 19 }    pingCtlIfIndex OBJECT-TYPE       SYNTAX      InterfaceIndexOrZero       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "Setting this object to an interface's ifIndex prior           to starting a remote ping operation directs           the ping probes to be transmitted over the           specified interface.  A value of zero for this object           means that this option is not enabled."       DEFVAL { 0 }       ::= { pingCtlEntry 20 }    pingCtlByPassRouteTable OBJECT-TYPE       SYNTAX      TruthValue       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION          "The purpose of this object is to enable optional          bypassing the route table.  If enabled, the remote          host will bypass the normal routing tables and send          directly to a host on an attached network.  If the          host is not on a directly attached network, an          error is returned.  This option can be used to perform          the ping operation to a local host through an          interface that has no route defined (e.g., after the          interface was dropped by the routing daemon at the host)."Quittek & White             Standards Track                    [Page 25]

RFC 4560                       REMOPS MIB                      June 2006       DEFVAL { false }       ::= { pingCtlEntry 21 }    pingCtlDSField OBJECT-TYPE       SYNTAX      Unsigned32 (0..255)       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "Specifies the value to store in the Type of Service           (TOS) octet in the IPv4 header or in the Traffic           Class octet in the IPv6 header, respectively, of the           IP packet used to encapsulate the ping probe.           The octet to be set in the IP header contains the           Differentiated Services (DS) Field in the six most           significant bits.           This option can be used to determine what effect an           explicit DS Field setting has on a ping response.           Not all values are legal or meaningful.  A value of 0           means that the function represented by this option is           not supported.  DS Field usage is often not supported           by IP implementations, and not all values are supported.           Refer toRFC 2474 andRFC 3260 for guidance on usage of           this field."       REFERENCE           "Refer toRFC 1812 for the definition of the IPv4 TOS           octet and toRFC 2460 for the definition of the IPv6           Traffic Class octet.  Refer toRFC 2474 andRFC 3260           for the definition of the Differentiated Services Field."       DEFVAL { 0 }       ::= { pingCtlEntry 22 }    pingCtlRowStatus OBJECT-TYPE       SYNTAX      RowStatus       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "This object allows entries to be created and deleted           in the pingCtlTable.  Deletion of an entry in this           table results in the deletion of all corresponding (same           pingCtlOwnerIndex and pingCtlTestName index values)           pingResultsTable and pingProbeHistoryTable entries.           A value MUST be specified for pingCtlTargetAddress           prior to acceptance of a transition to active(1) state.           When a value for pingCtlTargetAddress is set,Quittek & White             Standards Track                    [Page 26]

RFC 4560                       REMOPS MIB                      June 2006           the value of object pingCtlRowStatus changes           from notReady(3) to notInService(2).           Activation of a remote ping operation is controlled           via pingCtlAdminStatus, not by changing           this object's value to active(1).           Transitions in and out of active(1) state are not           allowed while an entry's pingResultsOperStatus is           active(1), with the exception that deletion of           an entry in this table by setting its RowStatus           object to destroy(6) will stop an active           ping operation.           The operational state of a ping operation           can be determined by examination of its           pingResultsOperStatus object."       REFERENCE           "See definition of RowStatus inRFC 2579, 'Textual           Conventions for SMIv2.'"       ::= { pingCtlEntry 23 }   -- Ping Results Table    pingResultsTable OBJECT-TYPE       SYNTAX      SEQUENCE OF PingResultsEntry       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION           "Defines the Ping Results Table for providing           the capability of performing ping operations at           a remote host.  The results of these operations are           stored in the pingResultsTable and the pingProbeHistoryTable.           An entry is added to the pingResultsTable when an           pingCtlEntry is started by successful transition           of its pingCtlAdminStatus object to enabled(1).           If the object pingCtlAdminStatus already has the value           enabled(1), and if the corresponding pingResultsOperStatus           object has the value completed(3), then successfully writing           enabled(1) to object pingCtlAdminStatus re-initializes the           already existing entry in the pingResultsTable.  The values           of objects in the re-initialized entry are the same as the           values of objects in a new entry would be.           An entry is removed from the pingResultsTable when           its corresponding pingCtlEntry is deleted."Quittek & White             Standards Track                    [Page 27]

RFC 4560                       REMOPS MIB                      June 2006      ::= { pingObjects 3 }    pingResultsEntry OBJECT-TYPE       SYNTAX      PingResultsEntry       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION           "Defines an entry in the pingResultsTable.  The           pingResultsTable has the same indexing as the           pingCtlTable so that a pingResultsEntry           corresponds to the pingCtlEntry that caused it to           be created."       INDEX {                pingCtlOwnerIndex,                pingCtlTestName             }       ::= { pingResultsTable 1 }    PingResultsEntry ::=       SEQUENCE {           pingResultsOperStatus          INTEGER,           pingResultsIpTargetAddressType InetAddressType,           pingResultsIpTargetAddress     InetAddress,           pingResultsMinRtt              Unsigned32,           pingResultsMaxRtt              Unsigned32,           pingResultsAverageRtt          Unsigned32,           pingResultsProbeResponses      Gauge32,           pingResultsSentProbes          Gauge32,           pingResultsRttSumOfSquares     Unsigned32,           pingResultsLastGoodProbe       DateAndTime        }    pingResultsOperStatus OBJECT-TYPE       SYNTAX      INTEGER {                             enabled(1),   -- test is in progress                             disabled(2),  -- test has stopped                             completed(3)  -- test is completed                           }       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "Reflects the operational state of a pingCtlEntry:              enabled(1)    - Test is active.              disabled(2)   - Test has stopped.              completed(3)  - Test is completed."       ::= { pingResultsEntry 1 }Quittek & White             Standards Track                    [Page 28]

RFC 4560                       REMOPS MIB                      June 2006    pingResultsIpTargetAddressType OBJECT-TYPE       SYNTAX      InetAddressType       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "This object indicates the type of address stored           in the corresponding pingResultsIpTargetAddress           object."       DEFVAL { unknown }       ::= { pingResultsEntry 2 }    pingResultsIpTargetAddress OBJECT-TYPE       SYNTAX      InetAddress       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "This object reports the IP address associated           with a pingCtlTargetAddress value when the destination           address is specified as a DNS name.  The value of           this object should be a zero-length octet string           when a DNS name is not specified or when a           specified DNS name fails to resolve.           The address type (InetAddressType) that relates to           this object is specified by the corresponding value           of pingResultsIpTargetAddressType."       DEFVAL { ''H }       ::= { pingResultsEntry 3 }    pingResultsMinRtt OBJECT-TYPE       SYNTAX      Unsigned32       UNITS       "milliseconds"       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "The minimum ping round-trip-time (RTT) received.  A value           of 0 for this object implies that no RTT has been received."       ::= { pingResultsEntry 4 }    pingResultsMaxRtt OBJECT-TYPE       SYNTAX      Unsigned32       UNITS       "milliseconds"       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "The maximum ping round-trip-time (RTT) received.  A value           of 0 for this object implies that no RTT has been received."Quittek & White             Standards Track                    [Page 29]

RFC 4560                       REMOPS MIB                      June 2006       ::= { pingResultsEntry 5 }     pingResultsAverageRtt OBJECT-TYPE       SYNTAX      Unsigned32       UNITS       "milliseconds"       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "The current average ping round-trip-time (RTT)."       ::= { pingResultsEntry 6 }     pingResultsProbeResponses OBJECT-TYPE       SYNTAX      Gauge32       UNITS       "responses"       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "Number of responses received for the corresponding           pingCtlEntry and pingResultsEntry.  The value of this object           MUST be reported as 0 when no probe responses have been           received."       ::= { pingResultsEntry 7 }     pingResultsSentProbes OBJECT-TYPE       SYNTAX      Gauge32       UNITS       "probes"       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "The value of this object reflects the number of probes sent           for the corresponding pingCtlEntry and pingResultsEntry.           The value of this object MUST be reported as 0 when no probes           have been sent."       ::= { pingResultsEntry 8 }     pingResultsRttSumOfSquares OBJECT-TYPE       SYNTAX      Unsigned32       UNITS       "milliseconds"       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "This object contains the sum of the squares for all ping           responses received.  Its purpose is to enable standard           deviation calculation.  The value of this object MUST           be reported as 0 when no ping responses have been           received."       ::= { pingResultsEntry 9 }Quittek & White             Standards Track                    [Page 30]

RFC 4560                       REMOPS MIB                      June 2006    pingResultsLastGoodProbe OBJECT-TYPE       SYNTAX      DateAndTime       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "Date and time when the last response was received for           a probe."       ::= { pingResultsEntry 10 }    -- Ping Probe History Table    pingProbeHistoryTable OBJECT-TYPE       SYNTAX      SEQUENCE OF PingProbeHistoryEntry       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION           "Defines a table for storing the results of ping           operations.  The number of entries in this table is           limited per entry in the pingCtlTable by the value           of the corresponding pingCtlMaxRows object.           An entry in this table is created when the result of           a ping probe is determined.  The initial 2 instance           identifier index values identify the pingCtlEntry           that a probe result (pingProbeHistoryEntry) belongs           to.  An entry is removed from this table when           its corresponding pingCtlEntry is deleted.           An implementation of this MIB will remove the oldest           entry in the pingProbeHistoryTable of the           corresponding entry in the pingCtlTable to allow           the addition of an new entry once the number of rows           in the pingProbeHistoryTable reaches the value           specified by pingCtlMaxRows for the corresponding           entry in the pingCtlTable."      ::= { pingObjects 4 }    pingProbeHistoryEntry OBJECT-TYPE       SYNTAX      PingProbeHistoryEntry       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION           "Defines an entry in the pingProbeHistoryTable.           The first two index elements identify the           pingCtlEntry that a pingProbeHistoryEntry belongs           to.  The third index element selects a single           probe result."       INDEX {Quittek & White             Standards Track                    [Page 31]

RFC 4560                       REMOPS MIB                      June 2006                pingCtlOwnerIndex,                pingCtlTestName,                pingProbeHistoryIndex              }       ::= { pingProbeHistoryTable 1 }    PingProbeHistoryEntry ::=       SEQUENCE {           pingProbeHistoryIndex         Unsigned32,           pingProbeHistoryResponse      Unsigned32,           pingProbeHistoryStatus        OperationResponseStatus,           pingProbeHistoryLastRC        Integer32,           pingProbeHistoryTime          DateAndTime       }    pingProbeHistoryIndex OBJECT-TYPE       SYNTAX      Unsigned32 (1..'ffffffff'h)       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION           "An entry in this table is created when the result of           a ping probe is determined.  The initial 2 instance           identifier index values identify the pingCtlEntry           that a probe result (pingProbeHistoryEntry) belongs           to.           An implementation MUST start assigning           pingProbeHistoryIndex values at 1 and wrap after           exceeding the maximum possible value as defined by           the limit of this object ('ffffffff'h)."       ::= { pingProbeHistoryEntry 1 }    pingProbeHistoryResponse OBJECT-TYPE       SYNTAX      Unsigned32       UNITS       "milliseconds"       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "The amount of time measured in milliseconds from when           a probe was sent to when its response was received or           when it timed out.  The value of this object is reported           as 0 when it is not possible to transmit a probe."       ::= { pingProbeHistoryEntry 2 }    pingProbeHistoryStatus OBJECT-TYPE       SYNTAX      OperationResponseStatus       MAX-ACCESS  read-only       STATUS      currentQuittek & White             Standards Track                    [Page 32]

RFC 4560                       REMOPS MIB                      June 2006       DESCRIPTION           "The result of a particular probe done by a remote host."       ::= { pingProbeHistoryEntry 3 }    pingProbeHistoryLastRC        OBJECT-TYPE       SYNTAX      Integer32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "The last implementation-method-specific reply code received.           If the ICMP Echo capability is being used, then a successful           probe ends when an ICMP response is received that contains           the code ICMP_ECHOREPLY(0).  The ICMP codes are maintained           by IANA.  Standardized ICMP codes are listed athttp://www.iana.org/assignments/icmp-parameters.           The ICMPv6 codes are listed athttp://www.iana.org/assignments/icmpv6-parameters."       ::= { pingProbeHistoryEntry 4 }    pingProbeHistoryTime OBJECT-TYPE       SYNTAX      DateAndTime       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "Timestamp for when this probe result was determined."       ::= { pingProbeHistoryEntry 5 }    -- Notification Definition section    pingProbeFailed NOTIFICATION-TYPE         OBJECTS {           pingCtlTargetAddressType,           pingCtlTargetAddress,           pingResultsOperStatus,           pingResultsIpTargetAddressType,           pingResultsIpTargetAddress,           pingResultsMinRtt,           pingResultsMaxRtt,           pingResultsAverageRtt,           pingResultsProbeResponses,           pingResultsSentProbes,           pingResultsRttSumOfSquares,           pingResultsLastGoodProbe         }         STATUS  current         DESCRIPTION             "Generated when a probe failure is detected, when theQuittek & White             Standards Track                    [Page 33]

RFC 4560                       REMOPS MIB                      June 2006             corresponding pingCtlTrapGeneration object is set to             probeFailure(0), subject to the value of             pingCtlTrapProbeFailureFilter.  The object             pingCtlTrapProbeFailureFilter can be used to specify the             number of consecutive probe failures that are required             before this notification can be generated."         ::= { pingNotifications 1 }    pingTestFailed NOTIFICATION-TYPE         OBJECTS {           pingCtlTargetAddressType,           pingCtlTargetAddress,           pingResultsOperStatus,           pingResultsIpTargetAddressType,           pingResultsIpTargetAddress,           pingResultsMinRtt,           pingResultsMaxRtt,           pingResultsAverageRtt,           pingResultsProbeResponses,           pingResultsSentProbes,           pingResultsRttSumOfSquares,           pingResultsLastGoodProbe         }         STATUS  current         DESCRIPTION             "Generated when a ping test is determined to have failed,             when the corresponding pingCtlTrapGeneration object is             set to testFailure(1).  In this instance,             pingCtlTrapTestFailureFilter should specify the number of             probes in a test required to have failed in order to             consider the test failed."         ::= { pingNotifications 2 }    pingTestCompleted NOTIFICATION-TYPE         OBJECTS {           pingCtlTargetAddressType,           pingCtlTargetAddress,           pingResultsOperStatus,           pingResultsIpTargetAddressType,           pingResultsIpTargetAddress,           pingResultsMinRtt,           pingResultsMaxRtt,           pingResultsAverageRtt,           pingResultsProbeResponses,           pingResultsSentProbes,           pingResultsRttSumOfSquares,           pingResultsLastGoodProbeQuittek & White             Standards Track                    [Page 34]

RFC 4560                       REMOPS MIB                      June 2006         }         STATUS  current         DESCRIPTION             "Generated at the completion of a ping test when the             corresponding pingCtlTrapGeneration object has the             testCompletion(2) bit set."         ::= { pingNotifications 3 }    -- Conformance information    -- Compliance statements    pingCompliances OBJECT IDENTIFIER ::= { pingConformance 1 }    pingGroups      OBJECT IDENTIFIER ::= { pingConformance 2 }    -- Compliance statements    pingFullCompliance MODULE-COMPLIANCE       STATUS  current       DESCRIPTION               "The compliance statement for SNMP entities that               fully implement the DISMAN-PING-MIB."       MODULE  -- this module           MANDATORY-GROUPS {                               pingMinimumGroup,                               pingCtlRowStatusGroup,                               pingHistoryGroup,                               pingNotificationsGroup                             }           OBJECT pingMaxConcurrentRequests           MIN-ACCESS  read-only           DESCRIPTION               "The agent is not required to support set               operations to this object."           OBJECT pingCtlStorageType           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required."           OBJECT pingCtlType           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required.  In addition, the only               value that MUST be supported by an implementation is               pingIcmpEcho."Quittek & White             Standards Track                    [Page 35]

RFC 4560                       REMOPS MIB                      June 2006           OBJECT pingCtlSourceAddressType           SYNTAX  InetAddressType { unknown(0), ipv4(1), ipv6(2) }           MIN-ACCESS  read-only           DESCRIPTION               "Write access to this object is not required by               implementations that are not capable of binding the               send socket with a source address.  An implementation               is only required to support IPv4 and IPv6 addresses."           OBJECT pingCtlSourceAddress           SYNTAX  InetAddress (SIZE(0|4|16))           MIN-ACCESS  read-only           DESCRIPTION               "Write access to this object is not required by               implementations that are not capable of binding the               send socket with a source address.  An implementation               is only required to support IPv4 and IPv6 addresses."           OBJECT pingCtlIfIndex           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required.  If write access is               not supported, return a 0 as the value of this object.               A value of 0 means that the function represented by               this option is not supported."           OBJECT pingCtlByPassRouteTable           MIN-ACCESS  read-only           DESCRIPTION               "Write access to this object is not required by               implementations that are not capable of its               implementation.  The function represented by this               object is implementable if the setsockopt               SOL_SOCKET SO_DONTROUTE option is supported."           OBJECT pingCtlDSField           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required.  If write access is               not supported, return a 0 as the value of this object.               A value of 0 means that the function represented by               this option is not supported."           OBJECT pingResultsIpTargetAddressType           SYNTAX  InetAddressType { unknown(0), ipv4(1), ipv6(2) }           DESCRIPTION               "An implementation is only required toQuittek & White             Standards Track                    [Page 36]

RFC 4560                       REMOPS MIB                      June 2006               support IPv4 and IPv6 addresses."           OBJECT pingResultsIpTargetAddress           SYNTAX  InetAddress (SIZE(0|4|16))           DESCRIPTION               "An implementation is only required to               support IPv4 and globally unique IPv6 addresses."           OBJECT pingResultsLastGoodProbe           DESCRIPTION               "This object is mandatory for implementations that have               access to a system clock and that are capable of setting               the values for DateAndTime objects.  It is RECOMMENDED               that when this object is not supported its values               be reported as '0000000000000000'H."           OBJECT pingProbeHistoryTime           DESCRIPTION               "This object is mandatory for implementations that have               access to a system clock and that are capable of setting               the values for DateAndTime objects.  It is RECOMMENDED               that when this object is not supported its values               be reported as '0000000000000000'H."       ::= { pingCompliances 2 }    pingMinimumCompliance MODULE-COMPLIANCE       STATUS  current       DESCRIPTION               "The minimum compliance statement for SNMP entities               that implement the minimal subset of the               DISMAN-PING-MIB.  Implementors might choose this               subset for small devices with limited resources."       MODULE  -- this module           MANDATORY-GROUPS { pingMinimumGroup }           GROUP pingCtlRowStatusGroup           DESCRIPTION               "A compliant implementation does not have to implement               the pingCtlRowStatusGroup."           GROUP pingHistoryGroup           DESCRIPTION               "A compliant implementation does not have to implement               the pingHistoryGroup."           GROUP pingNotificationsGroup           DESCRIPTION               "A compliant implementation does not have to implementQuittek & White             Standards Track                    [Page 37]

RFC 4560                       REMOPS MIB                      June 2006               the pingNotificationsGroup."           OBJECT pingMaxConcurrentRequests           MIN-ACCESS  read-only           DESCRIPTION               "The agent is not required to support set               operations to this object."           OBJECT pingCtlDataFill           MIN-ACCESS  read-only           DESCRIPTION               "The agent is not required to support set               operations to this object."           OBJECT pingCtlFrequency           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required.  If write access is               not supported, return a 0 as the value of this object.               A value of 0 means that the function represented by               this option is not supported."           OBJECT pingCtlMaxRows           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required.  If the               pingHistoryGroup is not implemented, then write               access to this object MUST be disabled, and the object               MUST return a value of 0 when retrieved."           OBJECT pingCtlStorageType           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required."           OBJECT pingCtlTrapGeneration           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required.  If the               pingNotificationsGroup is not implemented, then write               access to this object MUST be disabled, and the object               MUST return a value with no bit set when retrieved.               No bit set indicates that not notification is               generated."           OBJECT pingCtlTrapProbeFailureFilter           MIN-ACCESS  read-only           DESCRIPTIONQuittek & White             Standards Track                    [Page 38]

RFC 4560                       REMOPS MIB                      June 2006               "If write access to pingCtlTrapGeneration is not               supported, then write access to this object must also               not be supported.  In this case, return 0 as the value               of this object."           OBJECT pingCtlTrapTestFailureFilter           MIN-ACCESS  read-only           DESCRIPTION               "If write access to pingCtlTrapGeneration is not               supported, then write access to this object must also               not be supported.  In this case, return 0 as the value               of this object."           OBJECT pingCtlType           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required.  In addition, the only               value that MUST be supported by an implementation is               pingIcmpEcho."           OBJECT pingCtlDescr           MIN-ACCESS  read-only           DESCRIPTION               "The agent is not required to support set               operations to this object."           OBJECT pingCtlSourceAddressType           SYNTAX  InetAddressType { unknown(0), ipv4(1), ipv6(2) }           MIN-ACCESS  read-only           DESCRIPTION               "Write access to this object is not required by               implementations that are not capable of binding the               send socket with a source address.  An implementation               is only required to support IPv4 and IPv6 addresses."           OBJECT pingCtlSourceAddress           SYNTAX  InetAddress (SIZE(0|4|16))           MIN-ACCESS  read-only           DESCRIPTION               "Write access to this object is not required by               implementations that are not capable of binding the               send socket with a source address.  An implementation               is only required to support IPv4 and IPv6 addresses."           OBJECT pingCtlIfIndex           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required.  If write access isQuittek & White             Standards Track                    [Page 39]

RFC 4560                       REMOPS MIB                      June 2006               not supported, return a 0 as the value of this object.               A value of 0 means that the function represented by               this option is not supported."           OBJECT pingCtlByPassRouteTable           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required.  If write access is               not supported, return false(2) as the value of this               object.  A value of false(2) means that the function               represented by this option is not supported."           OBJECT pingCtlDSField           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required.  If write access is               not supported, return a 0 as the value of this object.               A value of 0 means that the function represented by               this option is not supported."           OBJECT pingResultsIpTargetAddressType           SYNTAX  InetAddressType { unknown(0), ipv4(1), ipv6(2) }           DESCRIPTION               "An implementation is only required to               support IPv4 and IPv6 addresses."           OBJECT pingResultsIpTargetAddress           SYNTAX  InetAddress (SIZE(0|4|16))           DESCRIPTION               "An implementation is only required to               support IPv4 and globally unique IPv6 addresses."           OBJECT pingResultsLastGoodProbe           DESCRIPTION               "This object is mandatory for implementations that have               access to a system clock and that are capable of setting               the values for DateAndTime objects.  It is RECOMMENDED               that when this object is not supported its values               be reported as '0000000000000000'H."           OBJECT pingProbeHistoryTime           DESCRIPTION               "If the pingHistoryGroup is implemented, then this               object is mandatory for implementations that have               access to a system clock and that are capable of setting               the values for DateAndTime objects.  It is RECOMMENDED               that when this object is not supported its valuesQuittek & White             Standards Track                    [Page 40]

RFC 4560                       REMOPS MIB                      June 2006               be reported as '0000000000000000'H."       ::= { pingCompliances 3 }    pingCompliance MODULE-COMPLIANCE       STATUS  deprecated       DESCRIPTION               "The compliance statement for the DISMAN-PING-MIB.  This               compliance statement has been deprecated because the               group pingGroup and the pingTimeStampGroup have been               split and deprecated.  The pingFullCompliance statement               is semantically identical to the deprecated               pingCompliance statement."       MODULE  -- this module           MANDATORY-GROUPS {                               pingGroup,                               pingNotificationsGroup                             }           GROUP pingTimeStampGroup           DESCRIPTION               "This group is mandatory for implementations that have               access to a system clock and that are capable of setting               the values for DateAndTime objects.  It is RECOMMENDED               that when this group is not supported the values               for the objects in this group be reported as               '0000000000000000'H."           OBJECT pingMaxConcurrentRequests           MIN-ACCESS  read-only           DESCRIPTION               "The agent is not required to support set               operations to this object."           OBJECT pingCtlStorageType           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required.  It is also allowed               that implementations support only the volatile               StorageType enumeration."           OBJECT pingCtlType           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required.  In addition, the only               value that MUST be supported by an implementation is               pingIcmpEcho."Quittek & White             Standards Track                    [Page 41]

RFC 4560                       REMOPS MIB                      June 2006           OBJECT pingCtlByPassRouteTable           MIN-ACCESS  read-only           DESCRIPTION               "This object is not required by implementations that               are not capable of its implementation.  The function               represented by this object is implementable if the               setsockopt SOL_SOCKET SO_DONTROUTE option is               supported."           OBJECT pingCtlSourceAddressType           SYNTAX  InetAddressType { unknown(0), ipv4(1), ipv6(2) }           MIN-ACCESS  read-only           DESCRIPTION               "This object is not required by implementations that               are not capable of binding the send socket with a               source address.  An implementation is only required to               support IPv4 and IPv6 addresses."           OBJECT pingCtlSourceAddress           SYNTAX  InetAddress (SIZE(0|4|16))           MIN-ACCESS  read-only           DESCRIPTION               "This object is not required by implementations that               are not capable of binding the send socket with a               source address.  An implementation is only required to               support IPv4 and globally unique IPv6 addresses."           OBJECT pingCtlIfIndex           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required.  When write access is               not supported, return a 0 as the value of this object.               A value of 0 means that the function represented by               this option is not supported."           OBJECT pingCtlDSField           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required.  When write access is               not supported, return a 0 as the value of this object.               A value of 0 means that the function represented by               this option is not supported."           OBJECT pingResultsIpTargetAddressType           SYNTAX  InetAddressType { unknown(0), ipv4(1), ipv6(2) }           DESCRIPTION               "An implementation is only required to               support IPv4 and IPv6 addresses."Quittek & White             Standards Track                    [Page 42]

RFC 4560                       REMOPS MIB                      June 2006           OBJECT pingResultsIpTargetAddress           SYNTAX  InetAddress (SIZE(0|4|16))           DESCRIPTION               "An implementation is only required to               support IPv4 and globally unique IPv6 addresses."       ::= { pingCompliances 1 }    -- MIB groupings    pingMinimumGroup OBJECT-GROUP      OBJECTS {                pingMaxConcurrentRequests,                pingCtlTargetAddressType,                pingCtlTargetAddress,                pingCtlDataSize,                pingCtlTimeOut,                pingCtlProbeCount,                pingCtlAdminStatus,                pingCtlDataFill,                pingCtlFrequency,                pingCtlMaxRows,                pingCtlStorageType,                pingCtlTrapGeneration,                pingCtlTrapProbeFailureFilter,                pingCtlTrapTestFailureFilter,                pingCtlType,                pingCtlDescr,                pingCtlByPassRouteTable,                pingCtlSourceAddressType,                pingCtlSourceAddress,                pingCtlIfIndex,                pingCtlDSField,                pingResultsOperStatus,                pingResultsIpTargetAddressType,                pingResultsIpTargetAddress,                pingResultsMinRtt,                pingResultsMaxRtt,                pingResultsAverageRtt,                pingResultsProbeResponses,                pingResultsSentProbes,                pingResultsRttSumOfSquares,                pingResultsLastGoodProbe              }      STATUS  current      DESCRIPTION          "The group of objects that constitute the remote ping          capability."Quittek & White             Standards Track                    [Page 43]

RFC 4560                       REMOPS MIB                      June 2006       ::= { pingGroups 4 }    pingCtlRowStatusGroup OBJECT-GROUP      OBJECTS {                pingCtlRowStatus              }      STATUS  current      DESCRIPTION          "The RowStatus object of the pingCtlTable."       ::= { pingGroups 5 }    pingHistoryGroup OBJECT-GROUP      OBJECTS {                pingProbeHistoryResponse,                pingProbeHistoryStatus,                pingProbeHistoryLastRC,                pingProbeHistoryTime              }      STATUS  current      DESCRIPTION          "The group of objects that constitute the history          capability."       ::= { pingGroups 6 }    pingNotificationsGroup NOTIFICATION-GROUP      NOTIFICATIONS {                pingProbeFailed,                pingTestFailed,                pingTestCompleted             }      STATUS        current      DESCRIPTION          "The notification that are required to be supported by          implementations of this MIB."      ::= { pingGroups 3 }    pingGroup OBJECT-GROUP      OBJECTS {                pingMaxConcurrentRequests,                pingCtlTargetAddressType,                pingCtlTargetAddress,                pingCtlDataSize,                pingCtlTimeOut,                pingCtlProbeCount,                pingCtlAdminStatus,                pingCtlDataFill,                pingCtlFrequency,Quittek & White             Standards Track                    [Page 44]

RFC 4560                       REMOPS MIB                      June 2006                pingCtlMaxRows,                pingCtlStorageType,                pingCtlTrapGeneration,                pingCtlTrapProbeFailureFilter,                pingCtlTrapTestFailureFilter,                pingCtlType,                pingCtlDescr,                pingCtlByPassRouteTable,                pingCtlSourceAddressType,                pingCtlSourceAddress,                pingCtlIfIndex,                pingCtlDSField,                pingCtlRowStatus,                pingResultsOperStatus,                pingResultsIpTargetAddressType,                pingResultsIpTargetAddress,                pingResultsMinRtt,                pingResultsMaxRtt,                pingResultsAverageRtt,                pingResultsProbeResponses,                pingResultsSentProbes,                pingResultsRttSumOfSquares,                pingProbeHistoryResponse,                pingProbeHistoryStatus,                pingProbeHistoryLastRC              }      STATUS  deprecated      DESCRIPTION          "The group of objects that constitute the remote ping          capability."       ::= { pingGroups 1 }    pingTimeStampGroup OBJECT-GROUP      OBJECTS {                pingResultsLastGoodProbe,                pingProbeHistoryTime              }      STATUS  deprecated      DESCRIPTION          "The group of DateAndTime objects."       ::= { pingGroups 2 }   ENDQuittek & White             Standards Track                    [Page 45]

RFC 4560                       REMOPS MIB                      June 20064.2.  DISMAN-TRACEROUTE-MIB   DISMAN-TRACEROUTE-MIB DEFINITIONS ::= BEGIN   IMPORTS       MODULE-IDENTITY, OBJECT-TYPE, Integer32,       Gauge32, Unsigned32, mib-2,       NOTIFICATION-TYPE,       OBJECT-IDENTITY           FROM SNMPv2-SMI                  --RFC2578       RowStatus, StorageType,       TruthValue, DateAndTime           FROM SNMPv2-TC                   --RFC2579       MODULE-COMPLIANCE, OBJECT-GROUP,       NOTIFICATION-GROUP           FROM SNMPv2-CONF                 --RFC2580       SnmpAdminString           FROM SNMP-FRAMEWORK-MIB          --RFC3411       InterfaceIndexOrZero                 --RFC2863           FROM IF-MIB       InetAddressType, InetAddress           FROM INET-ADDRESS-MIB            --RFC4001       OperationResponseStatus           FROM DISMAN-PING-MIB;            --RFC4560    traceRouteMIB MODULE-IDENTITY       LAST-UPDATED "200606130000Z"         -- 13 June 2006       ORGANIZATION "IETF Distributed Management Working Group"       CONTACT-INFO           "Juergen Quittek           NEC Europe Ltd.           Network Laboratories           Kurfuersten-Anlage 36           69115 Heidelberg           Germany           Phone: +49 6221 4342-115           Email: quittek@netlab.nec.de"       DESCRIPTION           "The Traceroute MIB (DISMAN-TRACEROUTE-MIB) provides           access to the traceroute capability at a remote host.           Copyright (C) The Internet Society (2006). This version of           this MIB module is part ofRFC 4560; see the RFC itself for           full legal notices."        --  Revision historyQuittek & White             Standards Track                    [Page 46]

RFC 4560                       REMOPS MIB                      June 2006        REVISION     "200606130000Z"         -- 13 June 2006        DESCRIPTION            "Updated version, published asRFC 4560.                - Correctly considered IPv6 in DESCRIPTION clause of                  object traceRouteCtlDataSize                - Replaced references toRFC 2575 byRFC 3415                - Replaced references toRFC 2571 byRFC 3411                - Replaced references toRFC 2851 byRFC 4001                - Clarified DESCRIPTION clause of object                  traceRouteResultsLastGoodPath                - Changed range of object traceRouteCtlInitialTtl                  from (0..255) to (1..255)                - Extended DESCRIPTION clause of traceRouteResultsTable                  describing re-initialization of entries                - Changed SYNTAX of traceRouteResultsTestAttempts and                  traceRouteResultsTestSuccesses from Unsigned32 to                  Gauge32                - Changed status of traceRouteCompliance to deprecated                - Added traceRouteFullCompliance and                  traceRouteMinimumCompliance                - Changed status of traceRouteGroup and                  traceRouteTimeStampGroup to deprecated                - Added traceRouteMinimumGroup,                  traceRouteCtlRowStatusGroup, and                  traceRouteHistoryGroup                - Changed DEFVAL of object                  traceRouteCtlTargetAddressType from { ipv4 }                  to { unknown }                - Changed DEFVAL of object traceRouteCtlDescr                  from { '00'H } to { ''H }                - Added DEFVAL for object traceRouteCtlTrapGeneration                  of DEFVAL { { } }"        REVISION     "200009210000Z"         -- 21 September 2000        DESCRIPTION            "Initial version, published asRFC 2925."       ::= { mib-2 81 }    -- Top level structure of the MIB    traceRouteNotifications  OBJECT IDENTIFIER ::= { traceRouteMIB 0 }    traceRouteObjects        OBJECT IDENTIFIER ::= { traceRouteMIB 1 }    traceRouteConformance    OBJECT IDENTIFIER ::= { traceRouteMIB 2 }    -- The registration node (point) for traceroute implementation types    traceRouteImplementationTypeDomains OBJECT IDENTIFIER    ::= { traceRouteMIB 3 }Quittek & White             Standards Track                    [Page 47]

RFC 4560                       REMOPS MIB                      June 2006    traceRouteUsingUdpProbes OBJECT-IDENTITY       STATUS      current       DESCRIPTION           "Indicates that an implementation is using UDP probes to           perform the traceroute operation."       ::= { traceRouteImplementationTypeDomains 1 }    -- Simple Object Definitions    traceRouteMaxConcurrentRequests OBJECT-TYPE       SYNTAX      Unsigned32       UNITS       "requests"       MAX-ACCESS  read-write       STATUS      current       DESCRIPTION          "The maximum number of concurrent active traceroute requests          that are allowed within an agent implementation.  A value          of 0 for this object implies that there is no limit for          the number of concurrent active requests in effect.          The limit applies only to new requests being activated.          When a new value is set, the agent will continue processing          all the requests already active, even if their number          exceeds the limit just imposed."       DEFVAL { 10 }       ::= { traceRouteObjects 1 }     -- Traceroute Control Table    traceRouteCtlTable OBJECT-TYPE       SYNTAX      SEQUENCE OF TraceRouteCtlEntry       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION           "Defines the Remote Operations Traceroute Control Table for           providing the capability of invoking traceroute from a remote           host.  The results of traceroute operations can be stored in           the traceRouteResultsTable, traceRouteProbeHistoryTable, and           the traceRouteHopsTable."      ::= { traceRouteObjects 2 }    traceRouteCtlEntry OBJECT-TYPE       SYNTAX      TraceRouteCtlEntry       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTIONQuittek & White             Standards Track                    [Page 48]

RFC 4560                       REMOPS MIB                      June 2006           "Defines an entry in the traceRouteCtlTable.  The first           index element, traceRouteCtlOwnerIndex, is of type           SnmpAdminString, a textual convention that allows for           use of the SNMPv3 View-Based Access Control Model           (RFC 3415, VACM) and that allows a management           application to identify its entries.  The second index,           traceRouteCtlTestName (also an SnmpAdminString),           enables the same management application to have           multiple requests outstanding."       INDEX {               traceRouteCtlOwnerIndex,               traceRouteCtlTestName             }       ::= { traceRouteCtlTable 1 }    TraceRouteCtlEntry ::=       SEQUENCE {         traceRouteCtlOwnerIndex         SnmpAdminString,         traceRouteCtlTestName           SnmpAdminString,         traceRouteCtlTargetAddressType  InetAddressType,         traceRouteCtlTargetAddress      InetAddress,         traceRouteCtlByPassRouteTable   TruthValue,         traceRouteCtlDataSize           Unsigned32,         traceRouteCtlTimeOut            Unsigned32,         traceRouteCtlProbesPerHop       Unsigned32,         traceRouteCtlPort               Unsigned32,         traceRouteCtlMaxTtl             Unsigned32,         traceRouteCtlDSField            Unsigned32,         traceRouteCtlSourceAddressType  InetAddressType,         traceRouteCtlSourceAddress      InetAddress,         traceRouteCtlIfIndex            InterfaceIndexOrZero,         traceRouteCtlMiscOptions        SnmpAdminString,         traceRouteCtlMaxFailures        Unsigned32,         traceRouteCtlDontFragment       TruthValue,         traceRouteCtlInitialTtl         Unsigned32,         traceRouteCtlFrequency          Unsigned32,         traceRouteCtlStorageType        StorageType,         traceRouteCtlAdminStatus        INTEGER,         traceRouteCtlDescr              SnmpAdminString,         traceRouteCtlMaxRows            Unsigned32,         traceRouteCtlTrapGeneration     BITS,         traceRouteCtlCreateHopsEntries  TruthValue,         traceRouteCtlType               OBJECT IDENTIFIER,         traceRouteCtlRowStatus          RowStatus       }    traceRouteCtlOwnerIndex OBJECT-TYPE       SYNTAX      SnmpAdminString (SIZE(0..32))Quittek & White             Standards Track                    [Page 49]

RFC 4560                       REMOPS MIB                      June 2006       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION          "To facilitate the provisioning of access control by a          security administrator using the View-Based Access          Control Model (RFC 3415, VACM) for tables in which          multiple users may need to create or          modify entries independently, the initial index is used as          an 'owner index'.  Such an initial index has a syntax of          SnmpAdminString and can thus be trivially mapped to a          securityName or groupName defined in VACM, in          accordance with a security policy.          When used in conjunction with such a security policy,          all entries in the table belonging to a particular user          (or group) will have the same value for this initial          index.  For a given user's entries in a particular          table, the object identifiers for the information in          these entries will have the same subidentifiers (except          for the 'column' subidentifier) up to the end of the          encoded owner index. To configure VACM to permit access          to this portion of the table, one would create          vacmViewTreeFamilyTable entries with the value of          vacmViewTreeFamilySubtree including the owner index          portion, and vacmViewTreeFamilyMask 'wildcarding' the          column subidentifier.  More elaborate configurations          are possible."       ::= { traceRouteCtlEntry 1 }     traceRouteCtlTestName OBJECT-TYPE       SYNTAX      SnmpAdminString (SIZE(0..32))       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION           "The name of a traceroute test.  This is locally unique,           within the scope of a traceRouteCtlOwnerIndex."       ::= { traceRouteCtlEntry 2 }    traceRouteCtlTargetAddressType OBJECT-TYPE       SYNTAX      InetAddressType       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "Specifies the type of host address to be used on the           traceroute request at the remote host."       DEFVAL { unknown }       ::= { traceRouteCtlEntry 3 }Quittek & White             Standards Track                    [Page 50]

RFC 4560                       REMOPS MIB                      June 2006    traceRouteCtlTargetAddress OBJECT-TYPE       SYNTAX      InetAddress       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "Specifies the host address used on the           traceroute request at the remote host.  The           host address type can be determined by           examining the value of the corresponding           traceRouteCtlTargetAddressType.           A value for this object MUST be set prior to           transitioning its corresponding traceRouteCtlEntry to           active(1) via traceRouteCtlRowStatus."       ::= { traceRouteCtlEntry 4 }    traceRouteCtlByPassRouteTable OBJECT-TYPE       SYNTAX TruthValue       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION          "The purpose of this object is to enable optional          bypassing the route table.  If enabled, the remote          host will bypass the normal routing tables and send          directly to a host on an attached network.  If the          host is not on a directly attached network, an          error is returned.  This option can be used to perform          the traceroute operation to a local host through an          interface that has no route defined (e.g., after the          interface was dropped by the routing daemon at the host)."       DEFVAL { false }       ::= { traceRouteCtlEntry 5 }    traceRouteCtlDataSize OBJECT-TYPE       SYNTAX      Unsigned32 (0..65507)       UNITS       "octets"       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "Specifies the size of the data portion of a traceroute           request, in octets.  If the RECOMMENDED traceroute method           (UDP datagrams as probes) is used, then the value           contained in this object MUST be applied.  If another           traceroute method is used for which the specified size           is not appropriate, then the implementation SHOULD use           whatever size (appropriate to the method) is closest to           the specified size.Quittek & White             Standards Track                    [Page 51]

RFC 4560                       REMOPS MIB                      June 2006           The maximum value for this object was computed by           subtracting the smallest possible IP header size of           20 octets (IPv4 header with no options) and the UDP           header size of 8 octets from the maximum IP packet size.           An IP packet has a maximum size of 65535 octets           (excluding IPv6 Jumbograms)."       DEFVAL { 0 }       ::= { traceRouteCtlEntry 6 }    traceRouteCtlTimeOut OBJECT-TYPE       SYNTAX      Unsigned32 (1..60)       UNITS       "seconds"       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "Specifies the time-out value, in seconds, for           a traceroute request."       DEFVAL { 3 }       ::= { traceRouteCtlEntry 7 }    traceRouteCtlProbesPerHop OBJECT-TYPE       SYNTAX      Unsigned32 (1..10)       UNITS       "probes"       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "Specifies the number of times to reissue a traceroute           request with the same time-to-live (TTL) value."       DEFVAL { 3 }       ::= { traceRouteCtlEntry 8 }    traceRouteCtlPort OBJECT-TYPE       SYNTAX      Unsigned32 (1..65535)       UNITS       "UDP Port"       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "Specifies the (initial) UDP port to send the traceroute           request to.  A port needs to be specified that is not in           use at the destination (target) host.  The default           value for this object is the IANA assigned port,           33434, for the traceroute function."       DEFVAL { 33434 }       ::= { traceRouteCtlEntry 9 }    traceRouteCtlMaxTtl OBJECT-TYPE       SYNTAX      Unsigned32 (1..255)       UNITS       "time-to-live value"Quittek & White             Standards Track                    [Page 52]

RFC 4560                       REMOPS MIB                      June 2006       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "Specifies the maximum time-to-live value."       DEFVAL { 30 }       ::= { traceRouteCtlEntry 10 }    traceRouteCtlDSField OBJECT-TYPE       SYNTAX      Unsigned32 (0..255)       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "Specifies the value to store in the Type of Service           (TOS) octet in the IPv4 header or in the Traffic           Class octet in the IPv6 header, respectively, of the           IP packet used to encapsulate the traceroute probe.           The octet to be set in the IP header contains the           Differentiated Services (DS) Field in the six most           significant bits.           This option can be used to determine what effect an           explicit DS Field setting has on a traceroute response.           Not all values are legal or meaningful.  A value of 0           means that the function represented by this option is           not supported.  DS Field usage is often not supported           by IP implementations, and not all values are supported.           Refer toRFC 2474 andRFC 3260 for guidance on usage of           this field."       REFERENCE           "Refer toRFC 1812 for the definition of the IPv4 TOS           octet and toRFC 2460 for the definition of the IPv6           Traffic Class octet.  Refer toRFC 2474 andRFC 3260           for the definition of the Differentiated Services Field."       DEFVAL { 0 }       ::= { traceRouteCtlEntry 11 }    traceRouteCtlSourceAddressType OBJECT-TYPE       SYNTAX      InetAddressType       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "Specifies the type of the source address,           traceRouteCtlSourceAddress, to be used at a remote host           when a traceroute operation is performed."       DEFVAL { unknown }       ::= { traceRouteCtlEntry 12 }Quittek & White             Standards Track                    [Page 53]

RFC 4560                       REMOPS MIB                      June 2006    traceRouteCtlSourceAddress OBJECT-TYPE       SYNTAX      InetAddress       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "Use the specified IP address (which must be given as an           IP number, not a hostname) as the source address in           outgoing probe packets.  On hosts with more than one IP           address, this option can be used to select the address           to be used.  If the IP address is not one of this           machine's interface addresses, an error is returned, and           nothing is sent.  A zero-length octet string value for           this object disables source address specification.           The address type (InetAddressType) that relates to           this object is specified by the corresponding value           of traceRouteCtlSourceAddressType."       DEFVAL { ''H }       ::= { traceRouteCtlEntry 13 }    traceRouteCtlIfIndex OBJECT-TYPE       SYNTAX      InterfaceIndexOrZero       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "Setting this object to an interface's ifIndex prior           to starting a remote traceroute operation directs           the traceroute probes to be transmitted over the           specified interface.  A value of zero for this object           implies that this option is not enabled."       DEFVAL { 0 }       ::= { traceRouteCtlEntry 14 }    traceRouteCtlMiscOptions OBJECT-TYPE       SYNTAX      SnmpAdminString       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "Enables an application to specify implementation-dependent           options."       DEFVAL { ''H }       ::= { traceRouteCtlEntry 15 }    traceRouteCtlMaxFailures OBJECT-TYPE       SYNTAX      Unsigned32 (0..255)       UNITS       "timeouts"       MAX-ACCESS  read-create       STATUS      current       DESCRIPTIONQuittek & White             Standards Track                    [Page 54]

RFC 4560                       REMOPS MIB                      June 2006           "The value of this object indicates the maximum number           of consecutive timeouts allowed before a remote traceroute           request is terminated.  A value of either 255 (maximum           hop count/possible TTL value) or 0 indicates that the           function of terminating a remote traceroute request when a           specific number of consecutive timeouts are detected is           disabled."       DEFVAL { 5 }       ::= { traceRouteCtlEntry 16 }    traceRouteCtlDontFragment OBJECT-TYPE       SYNTAX         TruthValue       MAX-ACCESS     read-create       STATUS         current       DESCRIPTION           "This object enables setting of the don't fragment flag (DF)           in the IP header for a probe.  Use of this object enables           a manual PATH MTU test is performed."       DEFVAL  { false }       ::= { traceRouteCtlEntry 17 }    traceRouteCtlInitialTtl OBJECT-TYPE       SYNTAX         Unsigned32 (1..255)       MAX-ACCESS     read-create       STATUS         current       DESCRIPTION           "The value of this object specifies the initial TTL value to           use.  This enables bypassing the initial (often well known)           portion of a path."       DEFVAL { 1 }       ::= { traceRouteCtlEntry 18 }    traceRouteCtlFrequency  OBJECT-TYPE       SYNTAX      Unsigned32       UNITS       "seconds"       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "The number of seconds to wait before repeating a           traceroute test, as defined by the value of the           various objects in the corresponding row.           After a single test is completed the number of seconds           as defined by the value of traceRouteCtlFrequency MUST           elapse before the next traceroute test is started.           A value of 0 for this object implies that the test           as defined by the corresponding entry will not beQuittek & White             Standards Track                    [Page 55]

RFC 4560                       REMOPS MIB                      June 2006           repeated."       DEFVAL { 0 }       ::= { traceRouteCtlEntry 19 }    traceRouteCtlStorageType OBJECT-TYPE       SYNTAX      StorageType       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "The storage type for this conceptual row.           Conceptual rows having the value 'permanent' need not           allow write-access to any columnar objects in the row."       DEFVAL { nonVolatile }       ::= { traceRouteCtlEntry 20 }    traceRouteCtlAdminStatus OBJECT-TYPE       SYNTAX      INTEGER {                             enabled(1), -- operation should be started                             disabled(2) -- operation should be stopped                           }       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "Reflects the desired state that an traceRouteCtlEntry           should be in:              enabled(1)  - Attempt to activate the test as defined by                            this traceRouteCtlEntry.              disabled(2) - Deactivate the test as defined by this                            traceRouteCtlEntry.           Refer to the corresponding traceRouteResultsOperStatus to           determine the operational state of the test defined by           this entry."        DEFVAL { disabled }       ::= { traceRouteCtlEntry 21 }    traceRouteCtlDescr OBJECT-TYPE       SYNTAX      SnmpAdminString       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "The purpose of this object is to provide a           descriptive name of the remote traceroute           test."       DEFVAL { ''H }       ::= { traceRouteCtlEntry 22 }Quittek & White             Standards Track                    [Page 56]

RFC 4560                       REMOPS MIB                      June 2006    traceRouteCtlMaxRows OBJECT-TYPE       SYNTAX      Unsigned32       UNITS       "rows"       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "The maximum number of corresponding entries allowed           in the traceRouteProbeHistoryTable.  An implementation           of this MIB will remove the oldest corresponding entry           in the traceRouteProbeHistoryTable to allow the           addition of an new entry once the number of           corresponding rows in the traceRouteProbeHistoryTable           reaches this value.           Old entries are not removed when a new test is           started.  Entries are added to the           traceRouteProbeHistoryTable until traceRouteCtlMaxRows           is reached before entries begin to be removed.           A value of 0 for this object disables creation of           traceRouteProbeHistoryTable entries."       DEFVAL      { 50 }       ::= { traceRouteCtlEntry 23 }    traceRouteCtlTrapGeneration OBJECT-TYPE       SYNTAX      BITS {                     pathChange(0),                     testFailure(1),                     testCompletion(2)                   }       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "The value of this object determines when and whether to           generate a notification for this entry:           pathChange(0)     - Generate a traceRoutePathChange               notification when the current path varies from a               previously determined path.           testFailure(1)    - Generate a traceRouteTestFailed               notification when the full path to a target               can't be determined.           testCompletion(2) - Generate a traceRouteTestCompleted               notification when the path to a target has been               determined.           The value of this object defaults to an empty set,           indicating that none of the above options has been           selected."Quittek & White             Standards Track                    [Page 57]

RFC 4560                       REMOPS MIB                      June 2006       DEFVAL { { } }       ::= { traceRouteCtlEntry 24 }    traceRouteCtlCreateHopsEntries OBJECT-TYPE       SYNTAX      TruthValue       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "The current path for a traceroute test is kept in the           traceRouteHopsTable on a per-hop basis when the value of           this object is true(1)."       DEFVAL { false }       ::= { traceRouteCtlEntry 25 }    traceRouteCtlType OBJECT-TYPE       SYNTAX      OBJECT IDENTIFIER       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "The value of this object is used either to report or to           select the implementation method to be used for           performing a traceroute operation.  The value of this           object may be selected from           traceRouteImplementationTypeDomains.           Additional implementation types should be allocated as           required by implementers of the DISMAN-TRACEROUTE-MIB           under their enterprise specific registration point,           not beneath traceRouteImplementationTypeDomains."       DEFVAL { traceRouteUsingUdpProbes }       ::= { traceRouteCtlEntry 26 }    traceRouteCtlRowStatus OBJECT-TYPE       SYNTAX      RowStatus       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "This object allows entries to be created and deleted           in the traceRouteCtlTable.  Deletion of an entry in           this table results in a deletion of all corresponding (same           traceRouteCtlOwnerIndex and traceRouteCtlTestName           index values) traceRouteResultsTable,           traceRouteProbeHistoryTable, and traceRouteHopsTable           entries.           A value MUST be specified for traceRouteCtlTargetAddress           prior to acceptance of a transition to active(1) state.Quittek & White             Standards Track                    [Page 58]

RFC 4560                       REMOPS MIB                      June 2006           When a value for pingCtlTargetAddress is set,           the value of object pingCtlRowStatus changes           from notReady(3) to notInService(2).           Activation of a remote traceroute operation is           controlled via traceRouteCtlAdminStatus, and not           by transitioning of this object's value to active(1).           Transitions in and out of active(1) state are not           allowed while an entry's traceRouteResultsOperStatus           is active(1), with the exception that deletion of           an entry in this table by setting its RowStatus           object to destroy(6) will stop an active           traceroute operation.           The operational state of an traceroute operation           can be determined by examination of the corresponding           traceRouteResultsOperStatus object."       REFERENCE           "See definition of RowStatus inRFC 2579, 'Textual           Conventions for SMIv2.'"       ::= { traceRouteCtlEntry 27 }    -- Traceroute Results Table    traceRouteResultsTable OBJECT-TYPE       SYNTAX      SEQUENCE OF TraceRouteResultsEntry       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION           "Defines the Remote Operations Traceroute Results Table for           keeping track of the status of a traceRouteCtlEntry.           An entry is added to the traceRouteResultsTable when an           traceRouteCtlEntry is started by successful transition           of its traceRouteCtlAdminStatus object to enabled(1).           If the object traceRouteCtlAdminStatus already has the value           enabled(1), and if the corresponding           traceRouteResultsOperStatus object has the value           completed(3), then successfully writing enabled(1) to the           object traceRouteCtlAdminStatus re-initializes the already           existing entry in the traceRouteResultsTable.  The values of           objects in the re-initialized entry are the same as           the values of objects in a new entry would be.           An entry is removed from the traceRouteResultsTable whenQuittek & White             Standards Track                    [Page 59]

RFC 4560                       REMOPS MIB                      June 2006           its corresponding traceRouteCtlEntry is deleted."      ::= { traceRouteObjects 3 }    traceRouteResultsEntry OBJECT-TYPE       SYNTAX      TraceRouteResultsEntry       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION           "Defines an entry in the traceRouteResultsTable.  The           traceRouteResultsTable has the same indexing as the           traceRouteCtlTable so that a traceRouteResultsEntry           corresponds to the traceRouteCtlEntry that caused it to           be created."       INDEX {               traceRouteCtlOwnerIndex,               traceRouteCtlTestName             }       ::= { traceRouteResultsTable 1 }    TraceRouteResultsEntry ::=       SEQUENCE {         traceRouteResultsOperStatus       INTEGER,         traceRouteResultsCurHopCount      Gauge32,         traceRouteResultsCurProbeCount    Gauge32,         traceRouteResultsIpTgtAddrType    InetAddressType,         traceRouteResultsIpTgtAddr        InetAddress,         traceRouteResultsTestAttempts     Gauge32,         traceRouteResultsTestSuccesses    Gauge32,         traceRouteResultsLastGoodPath     DateAndTime       }    traceRouteResultsOperStatus OBJECT-TYPE       SYNTAX      INTEGER {                             enabled(1),  -- test is in progress                             disabled(2), -- test has stopped                             completed(3) -- test is completed                           }       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "Reflects the operational state of an traceRouteCtlEntry:              enabled(1)   - Test is active.              disabled(2)  - Test has stopped.              completed(3) - Test is completed."       ::= { traceRouteResultsEntry 1 }    traceRouteResultsCurHopCount OBJECT-TYPEQuittek & White             Standards Track                    [Page 60]

RFC 4560                       REMOPS MIB                      June 2006       SYNTAX      Gauge32       UNITS       "hops"       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "Reflects the current TTL value (from 1 to           255) for a remote traceroute operation.           Maximum TTL value is determined by           traceRouteCtlMaxTtl."       ::= { traceRouteResultsEntry 2 }    traceRouteResultsCurProbeCount OBJECT-TYPE       SYNTAX      Gauge32       UNITS       "probes"       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "Reflects the current probe count (1..10) for           a remote traceroute operation.  The maximum           probe count is determined by           traceRouteCtlProbesPerHop."       ::= { traceRouteResultsEntry 3 }    traceRouteResultsIpTgtAddrType OBJECT-TYPE       SYNTAX      InetAddressType       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "This object indicates the type of address stored           in the corresponding traceRouteResultsIpTgtAddr           object."       ::= { traceRouteResultsEntry 4 }    traceRouteResultsIpTgtAddr OBJECT-TYPE       SYNTAX      InetAddress       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "This object reports the IP address associated           with a traceRouteCtlTargetAddress value when the           destination address is specified as a DNS name.           The value of this object should be a zero-length           octet string when a DNS name is not specified or           when a specified DNS name fails to resolve."       ::= { traceRouteResultsEntry 5 }    traceRouteResultsTestAttempts OBJECT-TYPEQuittek & White             Standards Track                    [Page 61]

RFC 4560                       REMOPS MIB                      June 2006       SYNTAX      Gauge32       UNITS       "tests"       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "The current number of attempts to determine a path           to a target.  The value of this object MUST be started           at 0."       ::= { traceRouteResultsEntry 6 }    traceRouteResultsTestSuccesses OBJECT-TYPE       SYNTAX      Gauge32       UNITS       "tests"       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "The current number of attempts to determine a path           to a target that have succeeded.  The value of this           object MUST be reported as 0 when no attempts have           succeeded."       ::= { traceRouteResultsEntry 7 }    traceRouteResultsLastGoodPath OBJECT-TYPE       SYNTAX      DateAndTime       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "The date and time when the last complete path           was determined.  A path is complete if responses           were received or timeout occurred for each hop on           the path; i.e., for each TTL value from the value           of the corresponding traceRouteCtlInitialTtl object           up to the end of the path or (if no reply from the           target IP address was received) up to the value of           the corresponding traceRouteCtlMaxTtl object."       ::= { traceRouteResultsEntry 8 }    -- Trace Route Probe History Table    traceRouteProbeHistoryTable OBJECT-TYPE       SYNTAX      SEQUENCE OF TraceRouteProbeHistoryEntry       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION           "Defines the Remote Operations Traceroute Results Table           for storing the results of a traceroute operation.           An implementation of this MIB will remove the oldestQuittek & White             Standards Track                    [Page 62]

RFC 4560                       REMOPS MIB                      June 2006           entry in the traceRouteProbeHistoryTable of the           corresponding entry in the traceRouteCtlTable to allow           the addition of a new entry once the number of rows in           the traceRouteProbeHistoryTable reaches the value specified           by traceRouteCtlMaxRows for the corresponding entry in the           traceRouteCtlTable."      ::= { traceRouteObjects 4 }    traceRouteProbeHistoryEntry OBJECT-TYPE       SYNTAX      TraceRouteProbeHistoryEntry       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION           "Defines a table for storing the results of a traceroute           operation.  Entries in this table are limited by           the value of the corresponding traceRouteCtlMaxRows           object.           The first two index elements identify the           traceRouteCtlEntry that a traceRouteProbeHistoryEntry           belongs to.  The third index element selects a single           traceroute operation result.  The fourth and fifth indexes           select the hop and the probe for a particular           traceroute operation."       INDEX {                traceRouteCtlOwnerIndex,                traceRouteCtlTestName,                traceRouteProbeHistoryIndex,                traceRouteProbeHistoryHopIndex,                traceRouteProbeHistoryProbeIndex             }       ::= { traceRouteProbeHistoryTable 1 }    TraceRouteProbeHistoryEntry ::=       SEQUENCE {         traceRouteProbeHistoryIndex         Unsigned32,         traceRouteProbeHistoryHopIndex      Unsigned32,         traceRouteProbeHistoryProbeIndex    Unsigned32,         traceRouteProbeHistoryHAddrType     InetAddressType,         traceRouteProbeHistoryHAddr         InetAddress,         traceRouteProbeHistoryResponse      Unsigned32,         traceRouteProbeHistoryStatus        OperationResponseStatus,         traceRouteProbeHistoryLastRC        Integer32,         traceRouteProbeHistoryTime          DateAndTime       }    traceRouteProbeHistoryIndex OBJECT-TYPEQuittek & White             Standards Track                    [Page 63]

RFC 4560                       REMOPS MIB                      June 2006       SYNTAX      Unsigned32 (1..'ffffffff'h)       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION           "An entry in this table is created when the result of           a traceroute probe is determined.  The initial 2 instance           identifier index values identify the traceRouteCtlEntry           that a probe result (traceRouteProbeHistoryEntry) belongs           to.  An entry is removed from this table when           its corresponding traceRouteCtlEntry is deleted.           An implementation MUST start assigning           traceRouteProbeHistoryIndex values at 1 and wrap after           exceeding the maximum possible value, as defined by the           limit of this object ('ffffffff'h)."       ::= { traceRouteProbeHistoryEntry 1 }    traceRouteProbeHistoryHopIndex OBJECT-TYPE       SYNTAX      Unsigned32 (1..255)       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION          "Indicates which hop in a traceroute path the probe's          results are for.  The value of this object is initially          determined by the value of traceRouteCtlInitialTtl."       ::= { traceRouteProbeHistoryEntry 2 }    traceRouteProbeHistoryProbeIndex OBJECT-TYPE       SYNTAX      Unsigned32 (1..10)       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION          "Indicates the index of a probe for a particular          hop in a traceroute path.  The number of probes per          hop is determined by the value of the corresponding          traceRouteCtlProbesPerHop object."       ::= { traceRouteProbeHistoryEntry 3 }    traceRouteProbeHistoryHAddrType OBJECT-TYPE       SYNTAX      InetAddressType       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "This objects indicates the type of address stored           in the corresponding traceRouteProbeHistoryHAddr           object."       ::= { traceRouteProbeHistoryEntry 4 }Quittek & White             Standards Track                    [Page 64]

RFC 4560                       REMOPS MIB                      June 2006    traceRouteProbeHistoryHAddr OBJECT-TYPE       SYNTAX      InetAddress       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION          "The address of a hop in a traceroute path.  This object          is not allowed to be a DNS name.  The value of the          corresponding object, traceRouteProbeHistoryHAddrType,          indicates this object's IP address type."       ::= { traceRouteProbeHistoryEntry 5 }    traceRouteProbeHistoryResponse OBJECT-TYPE       SYNTAX      Unsigned32       UNITS       "milliseconds"       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "The amount of time measured in milliseconds from when           a probe was sent to when its response was received or           when it timed out.  The value of this object is reported           as 0 when it is not possible to transmit a probe."       ::= { traceRouteProbeHistoryEntry 6 }    traceRouteProbeHistoryStatus OBJECT-TYPE       SYNTAX      OperationResponseStatus       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "The result of a traceroute operation made by a remote           host for a particular probe."       ::= { traceRouteProbeHistoryEntry 7 }    traceRouteProbeHistoryLastRC OBJECT-TYPE       SYNTAX      Integer32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "The last implementation-method-specific reply code received.           Traceroute is usually implemented by transmitting a series of           probe packets with increasing time-to-live values.  A probe           packet is a UDP datagram encapsulated into an IP packet.           Each hop in a path to the target (destination) host rejects           the probe packets (probe's TTL too small, ICMP reply) until           either the maximum TTL is exceeded or the target host is           received."       ::= { traceRouteProbeHistoryEntry 8 }Quittek & White             Standards Track                    [Page 65]

RFC 4560                       REMOPS MIB                      June 2006    traceRouteProbeHistoryTime OBJECT-TYPE       SYNTAX      DateAndTime       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "Timestamp for when this probe's results were determined."       ::= { traceRouteProbeHistoryEntry 9 }    -- Traceroute Hop Results Table    traceRouteHopsTable OBJECT-TYPE       SYNTAX      SEQUENCE OF TraceRouteHopsEntry       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION           "Defines the Remote Operations Traceroute Hop Table for           keeping track of the results of traceroute tests on a           per-hop basis."       ::= { traceRouteObjects 5 }    traceRouteHopsEntry OBJECT-TYPE       SYNTAX      TraceRouteHopsEntry       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION           "Defines an entry in the traceRouteHopsTable.           The first two index elements identify the           traceRouteCtlEntry that a traceRouteHopsEntry           belongs to.  The third index element,           traceRouteHopsHopIndex, selects a           hop in a traceroute path."       INDEX {               traceRouteCtlOwnerIndex,               traceRouteCtlTestName,               traceRouteHopsHopIndex             }       ::= { traceRouteHopsTable 1 }    TraceRouteHopsEntry ::=       SEQUENCE {           traceRouteHopsHopIndex         Unsigned32,           traceRouteHopsIpTgtAddressType InetAddressType,           traceRouteHopsIpTgtAddress     InetAddress,           traceRouteHopsMinRtt           Unsigned32,           traceRouteHopsMaxRtt           Unsigned32,           traceRouteHopsAverageRtt       Unsigned32,           traceRouteHopsRttSumOfSquares  Unsigned32,Quittek & White             Standards Track                    [Page 66]

RFC 4560                       REMOPS MIB                      June 2006           traceRouteHopsSentProbes       Unsigned32,           traceRouteHopsProbeResponses   Unsigned32,           traceRouteHopsLastGoodProbe    DateAndTime         }    traceRouteHopsHopIndex OBJECT-TYPE       SYNTAX      Unsigned32 (1..'ffffffff'h)       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION           "Specifies the hop index for a traceroute hop.  Values           for this object with respect to the same           traceRouteCtlOwnerIndex and traceRouteCtlTestName           MUST start at 1 and be given increasing values for           subsequent hops.  The value of traceRouteHopsHopIndex is not           necessarily the number of the hop on the traced path.           The traceRouteHopsTable keeps the current traceroute           path per traceRouteCtlEntry if enabled by           setting the corresponding traceRouteCtlCreateHopsEntries           to true(1).           All hops (traceRouteHopsTable entries) in a traceroute           path MUST be updated at the same time when a traceroute           operation is completed.  Care needs to be applied when a path           either changes or can't be determined.  The initial portion           of the path, up to the first hop change, MUST retain the           same traceRouteHopsHopIndex values.  The remaining portion           of the path SHOULD be assigned new traceRouteHopsHopIndex           values."       ::= { traceRouteHopsEntry 1 }    traceRouteHopsIpTgtAddressType OBJECT-TYPE       SYNTAX      InetAddressType       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "This object indicates the type of address stored           in the corresponding traceRouteHopsIpTgtAddress           object."       ::= { traceRouteHopsEntry 2 }    traceRouteHopsIpTgtAddress OBJECT-TYPE       SYNTAX      InetAddress       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "This object reports the IP address associated withQuittek & White             Standards Track                    [Page 67]

RFC 4560                       REMOPS MIB                      June 2006           the hop.  A value for this object should be reported           as a numeric IP address, not as a DNS name.           The address type (InetAddressType) that relates to           this object is specified by the corresponding value           of pingCtlSourceAddressType."       ::= { traceRouteHopsEntry 3 }    traceRouteHopsMinRtt OBJECT-TYPE       SYNTAX      Unsigned32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "The minimum traceroute round-trip-time (RTT) received for           this hop.  A value of 0 for this object implies that no           RTT has been received."       ::= { traceRouteHopsEntry 4 }    traceRouteHopsMaxRtt OBJECT-TYPE       SYNTAX      Unsigned32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "The maximum traceroute round-trip-time (RTT) received for           this hop.  A value of 0 for this object implies that no           RTT has been received."       ::= { traceRouteHopsEntry 5 }    traceRouteHopsAverageRtt OBJECT-TYPE       SYNTAX      Unsigned32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "The current average traceroute round-trip-time (RTT) for           this hop."       ::= { traceRouteHopsEntry 6 }    traceRouteHopsRttSumOfSquares OBJECT-TYPE       SYNTAX      Unsigned32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "This object contains the sum of the squares of all           round-trip-times received for this hop.  Its purpose is           to enable standard deviation calculation."       ::= { traceRouteHopsEntry 7 }    traceRouteHopsSentProbes OBJECT-TYPEQuittek & White             Standards Track                    [Page 68]

RFC 4560                       REMOPS MIB                      June 2006       SYNTAX      Unsigned32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "The value of this object reflects the number of probes sent           for this hop during this traceroute test.  The value of this           object should start at 0."       ::= { traceRouteHopsEntry 8 }    traceRouteHopsProbeResponses OBJECT-TYPE       SYNTAX      Unsigned32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "Number of responses received for this hop during this           traceroute test.  This value of this object should start           at 0."       ::= { traceRouteHopsEntry 9 }    traceRouteHopsLastGoodProbe OBJECT-TYPE       SYNTAX      DateAndTime       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "Date and time at which the last response was received for a            probe for this hop during this traceroute test."       ::= { traceRouteHopsEntry 10 }    -- Notification Definition section    traceRoutePathChange NOTIFICATION-TYPE         OBJECTS {           traceRouteCtlTargetAddressType,           traceRouteCtlTargetAddress,           traceRouteResultsIpTgtAddrType,           traceRouteResultsIpTgtAddr         }         STATUS  current         DESCRIPTION             "The path to a target has changed."         ::= { traceRouteNotifications 1 }    traceRouteTestFailed NOTIFICATION-TYPE         OBJECTS {           traceRouteCtlTargetAddressType,           traceRouteCtlTargetAddress,           traceRouteResultsIpTgtAddrType,           traceRouteResultsIpTgtAddrQuittek & White             Standards Track                    [Page 69]

RFC 4560                       REMOPS MIB                      June 2006         }         STATUS  current         DESCRIPTION             "Could not determine the path to a target."         ::= { traceRouteNotifications 2 }    traceRouteTestCompleted NOTIFICATION-TYPE         OBJECTS {           traceRouteCtlTargetAddressType,           traceRouteCtlTargetAddress,           traceRouteResultsIpTgtAddrType,           traceRouteResultsIpTgtAddr         }         STATUS  current         DESCRIPTION             "The path to a target has just been determined."         ::= { traceRouteNotifications 3 }    -- Conformance information    -- Compliance statements    traceRouteCompliances OBJECT IDENTIFIER         ::= { traceRouteConformance 1 }    traceRouteGroups      OBJECT IDENTIFIER         ::= { traceRouteConformance 2 }    -- Compliance statements    traceRouteFullCompliance MODULE-COMPLIANCE       STATUS  current       DESCRIPTION               "The compliance statement for SNMP entities that               fully implement the DISMAN-TRACEROUTE-MIB."       MODULE  -- this module           MANDATORY-GROUPS {                               traceRouteMinimumGroup,                               traceRouteCtlRowStatusGroup,                               traceRouteHistoryGroup                            }           GROUP traceRouteHopsTableGroup           DESCRIPTION               "This group lists the objects that make up a               traceRouteHopsEntry.  Support of the traceRouteHopsTable               is optional."           GROUP traceRouteNotificationsGroup           DESCRIPTIONQuittek & White             Standards Track                    [Page 70]

RFC 4560                       REMOPS MIB                      June 2006               "This group defines a collection of optional               notifications."           OBJECT traceRouteMaxConcurrentRequests           MIN-ACCESS  read-only           DESCRIPTION               "The agent is not required to support SET               operations to this object."           OBJECT traceRouteCtlByPassRouteTable           MIN-ACCESS  read-only           DESCRIPTION               "Write access to this object is not required by               implementations that are not capable of its               implementation.  The function represented by this               object is implementable if the setsockopt               SOL_SOCKET SO_DONTROUTE option is supported."           OBJECT traceRouteCtlDSField           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required.  If write access is               not supported, return a 0 as the value of this object.               A value of 0 implies that the function represented by               this option is not supported."           OBJECT traceRouteCtlSourceAddressType           SYNTAX  InetAddressType { unknown(0), ipv4(1), ipv6(2) }           MIN-ACCESS  read-only           DESCRIPTION               "Write access to this object is not required by               implementations that are not capable of binding the               send socket with a source address.  An implementation               is only required to support IPv4 and IPv6 addresses."           OBJECT traceRouteCtlSourceAddress           SYNTAX  InetAddress (SIZE(0|4|16))           MIN-ACCESS  read-only           DESCRIPTION               "Write access to this object is not required by               implementations that are not capable of binding the               send socket with a source address.  An implementation               is only required to support IPv4 and IPv6 addresses."           OBJECT traceRouteCtlIfIndex           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required.  If write access isQuittek & White             Standards Track                    [Page 71]

RFC 4560                       REMOPS MIB                      June 2006               not supported, return a 0 as the value of this object.               A value of 0 implies that the function represented by               this option is not supported."           OBJECT traceRouteCtlMiscOptions           MIN-ACCESS  read-only           DESCRIPTION               "Support of this object is optional.  If not               supporting, do not allow write access and return a               zero-length octet string as the value of the object."           OBJECT traceRouteCtlStorageType           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required.  It is also allowed               that implementations support only the volatile(2)               StorageType enumeration."           OBJECT traceRouteCtlType           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required.  In addition, the only               value that is RECOMMENDED to be supported by an               implementation is traceRouteUsingUdpProbes."           OBJECT traceRouteResultsIpTgtAddrType           SYNTAX  InetAddressType { unknown(0), ipv4(1), ipv6(2) }           DESCRIPTION               "An implementation should only support IPv4 and               globally unique IPv6 address values for this object."           OBJECT traceRouteResultsIpTgtAddr           SYNTAX  InetAddress (SIZE(0|4|16))           DESCRIPTION               "An implementation should only support IPv4 and               globally unique IPv6 address values for this object."           OBJECT traceRouteResultsLastGoodPath           DESCRIPTION               "If the traceRouteHopsTableGroup is implemented, then               this object is mandatory for implementations that have               access to a system clock and that are capable of setting               the values for DateAndTime objects.  It is RECOMMENDED               that when this object is not supported its values               be reported as '0000000000000000'H."           OBJECT traceRouteProbeHistoryHAddrType           SYNTAX  InetAddressType { unknown(0), ipv4(1), ipv6(2) }Quittek & White             Standards Track                    [Page 72]

RFC 4560                       REMOPS MIB                      June 2006           DESCRIPTION               "An implementation should only support IPv4 and               globally unique IPv6 address values for this object."           OBJECT traceRouteProbeHistoryHAddr           SYNTAX  InetAddress (SIZE(0|4|16))           DESCRIPTION               "An implementation should only support IPv4 and               globally unique IPv6 address values for this object."           OBJECT traceRouteProbeHistoryTime           DESCRIPTION               "This object is mandatory for implementations that have               access to a system clock and that are capable of setting               the values for DateAndTime objects.  It is RECOMMENDED               that when this object is not supported its values               be reported as '0000000000000000'H."           OBJECT traceRouteHopsIpTgtAddressType           SYNTAX  InetAddressType { unknown(0), ipv4(1), ipv6(2) }           DESCRIPTION               "An implementation should only support IPv4 and               globally unique IPv6 address values for this object."           OBJECT traceRouteHopsIpTgtAddress           SYNTAX  InetAddress (SIZE(0|4|16))           DESCRIPTION               "An implementation should only support IPv4 and               globally unique IPv6 address values for this object."           OBJECT traceRouteHopsLastGoodProbe           DESCRIPTION               "This object is mandatory for implementations that have               access to a system clock and that are capable of setting               the values for DateAndTime objects.  It is RECOMMENDED               that when this object is not supported its values               be reported as '0000000000000000'H."       ::= { traceRouteCompliances 2 }    traceRouteMinimumCompliance MODULE-COMPLIANCE       STATUS  current       DESCRIPTION               "The minimum compliance statement for SNMP entities               which implement the minimal subset of the               DISMAN-TRACEROUTE-MIB.  Implementors might choose this               subset for small devices with limited resources."       MODULE  -- this moduleQuittek & White             Standards Track                    [Page 73]

RFC 4560                       REMOPS MIB                      June 2006           MANDATORY-GROUPS { traceRouteMinimumGroup }           GROUP traceRouteCtlRowStatusGroup           DESCRIPTION               "A compliant implementation does not have to implement               the traceRouteCtlRowStatusGroup."           GROUP traceRouteHistoryGroup           DESCRIPTION               "A compliant implementation does not have to implement               the traceRouteHistoryGroup."           GROUP traceRouteHopsTableGroup           DESCRIPTION               "This group lists the objects that make up a               traceRouteHopsEntry.  Support of the traceRouteHopsTable               is optional."           GROUP traceRouteNotificationsGroup           DESCRIPTION               "This group defines a collection of optional               notifications."           OBJECT traceRouteMaxConcurrentRequests           MIN-ACCESS  read-only           DESCRIPTION               "The agent is not required to support SET               operations to this object."           OBJECT traceRouteCtlByPassRouteTable           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required.  If write access is               not supported, return a false(2) as the value of this               object.  A value of false(2) means that the function               represented by this option is not supported."           OBJECT traceRouteCtlDSField           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required.  If write access is               not supported, return a 0 as the value of this object.               A value of 0 implies that the function represented by               this option is not supported."           OBJECT traceRouteCtlSourceAddressType           SYNTAX  InetAddressType { unknown(0), ipv4(1), ipv6(2) }           MIN-ACCESS  read-onlyQuittek & White             Standards Track                    [Page 74]

RFC 4560                       REMOPS MIB                      June 2006           DESCRIPTION               "Write access to this object is not required by               implementations that are not capable of binding the               send socket with a source address.  An implementation               is only required to support IPv4 and IPv6 addresses."           OBJECT traceRouteCtlSourceAddress           SYNTAX  InetAddress (SIZE(0|4|16))           MIN-ACCESS  read-only           DESCRIPTION               "Write access to this object is not required by               implementations that are not capable of binding the               send socket with a source address.  An implementation               is only required to support IPv4 and IPv6 addresses."           OBJECT traceRouteCtlIfIndex           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required.  If write access is               not supported, return a 0 as the value of this object.               A value of 0 implies that the function represented by               this option is not supported."           OBJECT traceRouteCtlMiscOptions           MIN-ACCESS  read-only           DESCRIPTION               "Support of this object is optional.  If not               supporting, do not allow write access, and return a               zero-length octet string as the value of the object."           OBJECT traceRouteCtlDontFragment           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required.  If write access is               not supported, return a false(2) as the value of this               object.  A value of false(2) means that the function               represented by this option is not supported."           OBJECT traceRouteCtlInitialTtl           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required.  If write access is               not supported, return a 1 as the value of this object."           OBJECT traceRouteCtlFrequency           MIN-ACCESS  read-only           DESCRIPTIONQuittek & White             Standards Track                    [Page 75]

RFC 4560                       REMOPS MIB                      June 2006               "Write access is not required.  If write access is               not supported, return a 0 as the value of this object.               A value of 0 implies that the function represented by               this option is not supported."           OBJECT traceRouteCtlStorageType           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required.  It is also allowed               that implementations support only the volatile(2)               StorageType enumeration."           OBJECT traceRouteCtlDescr           MIN-ACCESS  read-only           DESCRIPTION               "The agent is not required to support set               operations to this object."           OBJECT traceRouteCtlMaxRows           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required.  If the               traceRouteHistoryGroup is not implemented, then write               access to this object MUST be disabled, and the object               MUST return a value of 0 when retrieved."           OBJECT traceRouteCtlTrapGeneration           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required.  If the               traceRouteNotificationsGroup is not implemented, then               write access to this object MUST be disabled, and the               object MUST return a value with no bit set when               retrieved.  No bit set indicates that no notification               is generated."           OBJECT traceRouteCtlCreateHopsEntries           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required.  If the               traceRouteHopsTableGroup is not implemented, then               write access to this object MUST be disabled, and the               object MUST return a value of false(2) when retrieved."           OBJECT traceRouteCtlType           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required.  In addition, the onlyQuittek & White             Standards Track                    [Page 76]

RFC 4560                       REMOPS MIB                      June 2006               value that is RECOMMENDED to be supported by an               implementation is traceRouteUsingUdpProbes."           OBJECT traceRouteResultsIpTgtAddrType           SYNTAX  InetAddressType { unknown(0), ipv4(1), ipv6(2) }           DESCRIPTION               "An implementation should only support IPv4 and               globally unique IPv6 address values for this object."           OBJECT traceRouteResultsIpTgtAddr           SYNTAX  InetAddress (SIZE(0|4|16))           DESCRIPTION               "An implementation should only support IPv4 and               globally unique IPv6 address values for this object."           OBJECT traceRouteResultsLastGoodPath           DESCRIPTION               "This object is mandatory for implementations that have               access to a system clock and that are capable of setting               the values for DateAndTime objects.  It is RECOMMENDED               that when this object is not supported its values               be reported as '0000000000000000'H."           OBJECT traceRouteProbeHistoryHAddrType           SYNTAX  InetAddressType { unknown(0), ipv4(1), ipv6(2) }           DESCRIPTION               "An implementation should only support IPv4 and               globally unique IPv6 address values for this object."           OBJECT traceRouteProbeHistoryHAddr           SYNTAX  InetAddress (SIZE(0|4|16))           DESCRIPTION               "An implementation should only support IPv4 and               globally unique IPv6 address values for this object."           OBJECT traceRouteProbeHistoryTime           DESCRIPTION               "If the traceRouteHistoryGroup is implemented, then               this object is mandatory for implementations that have               access to a system clock and that are capable of setting               the values for DateAndTime objects.  It is RECOMMENDED               that when this object is not supported its values               be reported as '0000000000000000'H."           OBJECT traceRouteHopsIpTgtAddressType           SYNTAX  InetAddressType { unknown(0), ipv4(1), ipv6(2) }           DESCRIPTION               "An implementation should only support IPv4 andQuittek & White             Standards Track                    [Page 77]

RFC 4560                       REMOPS MIB                      June 2006               globally unique IPv6 address values for this object."           OBJECT traceRouteHopsIpTgtAddress           SYNTAX  InetAddress (SIZE(0|4|16))           DESCRIPTION               "An implementation should only support IPv4 and               globally unique IPv6 address values for this object."           OBJECT traceRouteHopsLastGoodProbe           DESCRIPTION               "If the traceRouteHopsTableGroup is implemented, then               this object is mandatory for implementations that have               access to a system clock and that are capable of setting               the values for DateAndTime objects.  It is RECOMMENDED               that when this object is not supported its values               be reported as '0000000000000000'H."       ::= { traceRouteCompliances 3 }    traceRouteCompliance MODULE-COMPLIANCE       STATUS  deprecated       DESCRIPTION               "The compliance statement for the DISMAN-TRACEROUTE-MIB.               This compliance statement has been deprecated because               the traceRouteGroup and the traceRouteTimeStampGroup               have been split and deprecated. The               traceRouteFullCompliance is semantically identical to the               deprecated traceRouteCompliance statement."       MODULE  -- this module           MANDATORY-GROUPS {                               traceRouteGroup                             }           GROUP traceRouteTimeStampGroup           DESCRIPTION               "This group is mandatory for implementations that have               access to a system clock and that are capable of setting               the values for DateAndTime objects."           GROUP traceRouteNotificationsGroup           DESCRIPTION               "This group defines a collection of optional               notifications."           GROUP traceRouteHopsTableGroup           DESCRIPTION               "This group lists the objects that make up a               traceRouteHopsEntry.  Support of the traceRouteHopsTable               is optional."Quittek & White             Standards Track                    [Page 78]

RFC 4560                       REMOPS MIB                      June 2006           OBJECT traceRouteMaxConcurrentRequests           MIN-ACCESS  read-only           DESCRIPTION               "The agent is not required to support SET               operations to this object."           OBJECT traceRouteCtlByPassRouteTable           MIN-ACCESS  read-only           DESCRIPTION               "This object is not required by implementations that               are not capable of its implementation.  The function               represented by this object is implementable if the               setsockopt SOL_SOCKET SO_DONTROUTE option is               supported."           OBJECT traceRouteCtlSourceAddressType           SYNTAX  InetAddressType { unknown(0), ipv4(1), ipv6(2) }           MIN-ACCESS  read-only           DESCRIPTION               "This object is not required by implementations that               are not capable of binding the send socket with a               source address.  An implementation is only required to               support IPv4 and IPv6 addresses."           OBJECT traceRouteCtlSourceAddress           SYNTAX  InetAddress (SIZE(0|4|16))           MIN-ACCESS  read-only           DESCRIPTION               "This object is not required by implementations that               are not capable of binding the send socket with a               source address.  An implementation is only required to               support IPv4 and globally unique IPv6 addresses."           OBJECT traceRouteCtlIfIndex           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required.  When write access is               not supported, return a 0 as the value of this object.               A value of 0 implies that the function represented by               this option is not supported."           OBJECT traceRouteCtlMiscOptions           MIN-ACCESS  read-only           DESCRIPTION               "Support of this object is optional.  When not               supporting, do not allow write access, and return a               zero-length octet string as the value of the object."Quittek & White             Standards Track                    [Page 79]

RFC 4560                       REMOPS MIB                      June 2006           OBJECT traceRouteCtlStorageType           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required.  It is also allowed              that implementations support only the volatile               StorageType enumeration."           OBJECT traceRouteCtlDSField           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required.  When write access is               not supported, return a 0 as the value of this object.               A value of 0 implies that the function represented by               this option is not supported."           OBJECT traceRouteCtlType           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required.  In addition, the only               value that is RECOMMENDED to be supported by an               implementation is traceRouteUsingUdpProbes."           OBJECT traceRouteResultsIpTgtAddrType           SYNTAX  InetAddressType { unknown(0), ipv4(1), ipv6(2) }           DESCRIPTION               "An implementation should only support IPv4 and               globally unique IPv6 address values for this object."           OBJECT traceRouteResultsIpTgtAddr           SYNTAX  InetAddress (SIZE(0|4|16))           DESCRIPTION               "An implementation should only support IPv4 and               globally unique IPv6 address values for this object."           OBJECT traceRouteProbeHistoryHAddrType           SYNTAX  InetAddressType { unknown(0), ipv4(1), ipv6(2) }           DESCRIPTION               "An implementation should only support IPv4 and               globally unique IPv6 address values for this object."           OBJECT traceRouteProbeHistoryHAddr           SYNTAX  InetAddress (SIZE(0|4|16))           DESCRIPTION               "An implementation should only support IPv4 and               globally unique IPv6 address values for this object."           OBJECT traceRouteHopsIpTgtAddressType           SYNTAX  InetAddressType { unknown(0), ipv4(1), ipv6(2) }Quittek & White             Standards Track                    [Page 80]

RFC 4560                       REMOPS MIB                      June 2006           DESCRIPTION               "An implementation should only support IPv4 and               globally unique IPv6 address values for this object."           OBJECT traceRouteHopsIpTgtAddress           SYNTAX  InetAddress (SIZE(0|4|16))           DESCRIPTION               "An implementation should only support IPv4 and               globally unique IPv6 address values for this object."       ::= { traceRouteCompliances 1 }    -- MIB groupings    traceRouteMinimumGroup OBJECT-GROUP      OBJECTS {                traceRouteMaxConcurrentRequests,                traceRouteCtlTargetAddressType,                traceRouteCtlTargetAddress,                traceRouteCtlByPassRouteTable,                traceRouteCtlDataSize,                traceRouteCtlTimeOut,                traceRouteCtlProbesPerHop,                traceRouteCtlPort,                traceRouteCtlMaxTtl,                traceRouteCtlDSField,                traceRouteCtlSourceAddressType,                traceRouteCtlSourceAddress,                traceRouteCtlIfIndex,                traceRouteCtlMiscOptions,                traceRouteCtlMaxFailures,                traceRouteCtlDontFragment,                traceRouteCtlInitialTtl,                traceRouteCtlFrequency,                traceRouteCtlStorageType,                traceRouteCtlAdminStatus,                traceRouteCtlMaxRows,                traceRouteCtlTrapGeneration,                traceRouteCtlDescr,                traceRouteCtlCreateHopsEntries,                traceRouteCtlType,                traceRouteResultsOperStatus,                traceRouteResultsCurHopCount,                traceRouteResultsCurProbeCount,                traceRouteResultsIpTgtAddrType,                traceRouteResultsIpTgtAddr,                traceRouteResultsTestAttempts,                traceRouteResultsTestSuccesses,                traceRouteResultsLastGoodPathQuittek & White             Standards Track                    [Page 81]

RFC 4560                       REMOPS MIB                      June 2006             }      STATUS  current      DESCRIPTION          "The group of objects that constitute the remote traceroute          operation."      ::= { traceRouteGroups 5 }    traceRouteCtlRowStatusGroup OBJECT-GROUP      OBJECTS {                traceRouteCtlRowStatus             }      STATUS  current      DESCRIPTION          "The RowStatus object of the traceRouteCtlTable."      ::= { traceRouteGroups 6 }    traceRouteHistoryGroup OBJECT-GROUP      OBJECTS {                traceRouteProbeHistoryHAddrType,                traceRouteProbeHistoryHAddr,                traceRouteProbeHistoryResponse,                traceRouteProbeHistoryStatus,                traceRouteProbeHistoryLastRC,                traceRouteProbeHistoryTime              }      STATUS  current      DESCRIPTION          "The group of objects that constitute the history          capability."       ::= { traceRouteGroups 7 }    traceRouteNotificationsGroup NOTIFICATION-GROUP      NOTIFICATIONS {                traceRoutePathChange,                traceRouteTestFailed,                traceRouteTestCompleted             }      STATUS   current      DESCRIPTION          "The notifications that are required to be supported by          implementations of this MIB."      ::= { traceRouteGroups 3 }    traceRouteHopsTableGroup OBJECT-GROUP      OBJECTS {                traceRouteHopsIpTgtAddressType,                traceRouteHopsIpTgtAddress,Quittek & White             Standards Track                    [Page 82]

RFC 4560                       REMOPS MIB                      June 2006                traceRouteHopsMinRtt,                traceRouteHopsMaxRtt,                traceRouteHopsAverageRtt,                traceRouteHopsRttSumOfSquares,                traceRouteHopsSentProbes,                traceRouteHopsProbeResponses,                traceRouteHopsLastGoodProbe              }       STATUS   current       DESCRIPTION           "The group of objects that constitute the           traceRouteHopsTable."     ::= { traceRouteGroups 4 }    traceRouteGroup OBJECT-GROUP      OBJECTS {                traceRouteMaxConcurrentRequests,                traceRouteCtlTargetAddressType,                traceRouteCtlTargetAddress,                traceRouteCtlByPassRouteTable,                traceRouteCtlDataSize,                traceRouteCtlTimeOut,                traceRouteCtlProbesPerHop,                traceRouteCtlPort,                traceRouteCtlMaxTtl,                traceRouteCtlDSField,                traceRouteCtlSourceAddressType,                traceRouteCtlSourceAddress,                traceRouteCtlIfIndex,                traceRouteCtlMiscOptions,                traceRouteCtlMaxFailures,                traceRouteCtlDontFragment,                traceRouteCtlInitialTtl,                traceRouteCtlFrequency,                traceRouteCtlStorageType,                traceRouteCtlAdminStatus,                traceRouteCtlMaxRows,                traceRouteCtlTrapGeneration,                traceRouteCtlDescr,                traceRouteCtlCreateHopsEntries,                traceRouteCtlType,                traceRouteCtlRowStatus,                traceRouteResultsOperStatus,                traceRouteResultsCurHopCount,                traceRouteResultsCurProbeCount,                traceRouteResultsIpTgtAddrType,                traceRouteResultsIpTgtAddr,                traceRouteResultsTestAttempts,Quittek & White             Standards Track                    [Page 83]

RFC 4560                       REMOPS MIB                      June 2006                traceRouteResultsTestSuccesses,                traceRouteProbeHistoryHAddrType,                traceRouteProbeHistoryHAddr,                traceRouteProbeHistoryResponse,                traceRouteProbeHistoryStatus,                traceRouteProbeHistoryLastRC             }      STATUS  deprecated      DESCRIPTION          "The group of objects that constitute the remote traceroute          operation."      ::= { traceRouteGroups 1 }    traceRouteTimeStampGroup OBJECT-GROUP      OBJECTS {                traceRouteResultsLastGoodPath,                traceRouteProbeHistoryTime              }      STATUS  deprecated      DESCRIPTION          "The group of DateAndTime objects."       ::= { traceRouteGroups 2 }   END4.3.  DISMAN-NSLOOKUP-MIB   DISMAN-NSLOOKUP-MIB DEFINITIONS ::= BEGIN   IMPORTS       MODULE-IDENTITY, OBJECT-TYPE,       Unsigned32, mib-2, Integer32           FROM SNMPv2-SMI                  --RFC2578       RowStatus           FROM SNMPv2-TC                   --RFC2579       MODULE-COMPLIANCE, OBJECT-GROUP           FROM SNMPv2-CONF                 --RFC2580       SnmpAdminString           FROM SNMP-FRAMEWORK-MIB          --RFC3411       InetAddressType, InetAddress           FROM INET-ADDRESS-MIB;           --RFC4001    lookupMIB MODULE-IDENTITY       LAST-UPDATED "200606130000Z"         -- 13 June 2006       ORGANIZATION "IETF Distributed Management Working Group"       CONTACT-INFO           "Juergen QuittekQuittek & White             Standards Track                    [Page 84]

RFC 4560                       REMOPS MIB                      June 2006           NEC Europe Ltd.           Network Laboratories           Kurfuersten-Anlage 36           69115 Heidelberg           Germany           Phone: +49 6221 4342-115           Email: quittek@netlab.nec.de"       DESCRIPTION           "The Lookup MIB (DISMAN-NSLOOKUP-MIB) enables determination           of either the name(s) corresponding to a host address or of           the address(es) associated with a host name at a remote           host.           Copyright (C) The Internet Society (2006).  This version of           this MIB module is part ofRFC 4560; see the RFC itself for           full legal notices."        --  Revision history        REVISION     "200606130000Z"         -- 13 June 2006        DESCRIPTION            "Updated version, published asRFC 4560.                - Replaced references toRFC 2575 byRFC 3415                - Replaced references toRFC 2571 byRFC 3411                - Replaced references toRFC 2851 byRFC 4001                - Added value enabled(1) to SYNTAX clause of                  lookupCtlOperStatus                - Added lookupMinimumCompliance                - Defined semantics of value 0 for object                  lookupPurgeTime                - Added DEFVAL { unknown } to object                  lookupCtlTargetAddressType OBJECT-TYPE"        REVISION     "200009210000Z"         -- 21 September 2000        DESCRIPTION            "Initial version, published asRFC 2925."       ::= { mib-2 82 }    -- Top level structure of the MIB    lookupObjects        OBJECT IDENTIFIER ::= { lookupMIB 1 }    lookupConformance    OBJECT IDENTIFIER ::= { lookupMIB 2 }    -- Simple Object Definitions    lookupMaxConcurrentRequests OBJECT-TYPEQuittek & White             Standards Track                    [Page 85]

RFC 4560                       REMOPS MIB                      June 2006       SYNTAX      Unsigned32       UNITS       "requests"       MAX-ACCESS  read-write       STATUS      current       DESCRIPTION          "The maximum number of concurrent active lookup requests          that are allowed within an agent implementation.  A value          of 0 for this object implies that there is no limit for          the number of concurrent active requests in effect.          The limit applies only to new requests being activated.          When a new value is set, the agent will continue processing          all the requests already active, even if their number          exceed the limit just imposed."       DEFVAL { 10 }       ::= { lookupObjects 1 }    lookupPurgeTime OBJECT-TYPE       SYNTAX      Unsigned32 (0..86400)       UNITS       "seconds"       MAX-ACCESS  read-write       STATUS      current       DESCRIPTION          "The amount of time to wait before automatically          deleting an entry in the lookupCtlTable and any          dependent lookupResultsTable entries          after the lookup operation represented by a          lookupCtlEntry has been completed.          A lookupCtEntry is considered complete          when its lookupCtlOperStatus object has a          value of completed(3).          A value of 0 indicates that automatic deletion          of entries is disabled."       DEFVAL { 900 }  -- 15 minutes as default       ::= { lookupObjects 2 }    -- Lookup Control Table    lookupCtlTable OBJECT-TYPE       SYNTAX      SEQUENCE OF LookupCtlEntry       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION           "Defines the Lookup Control Table for providing           the capability of performing a lookup operation           for a symbolic host name or for a host address           from a remote host."Quittek & White             Standards Track                    [Page 86]

RFC 4560                       REMOPS MIB                      June 2006      ::= { lookupObjects 3 }    lookupCtlEntry OBJECT-TYPE       SYNTAX      LookupCtlEntry       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION           "Defines an entry in the lookupCtlTable.  A           lookupCtlEntry is initially indexed by           lookupCtlOwnerIndex, which is a type of SnmpAdminString,           a textual convention that allows for the use of the SNMPv3           View-Based Access Control Model (RFC 3415, VACM)           and that also allows a management application to identify           its entries.  The second index element,           lookupCtlOperationName, enables the same           lookupCtlOwnerIndex entity to have multiple outstanding           requests.  The value of lookupCtlTargetAddressType           determines which lookup function to perform."       INDEX {                lookupCtlOwnerIndex,                lookupCtlOperationName             }       ::= { lookupCtlTable 1 }    LookupCtlEntry ::=       SEQUENCE {           lookupCtlOwnerIndex         SnmpAdminString,           lookupCtlOperationName      SnmpAdminString,           lookupCtlTargetAddressType  InetAddressType,           lookupCtlTargetAddress      InetAddress,           lookupCtlOperStatus         INTEGER,           lookupCtlTime               Unsigned32,           lookupCtlRc                 Integer32,           lookupCtlRowStatus          RowStatus       }    lookupCtlOwnerIndex OBJECT-TYPE       SYNTAX      SnmpAdminString (SIZE(0..32))       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION          "To facilitate the provisioning of access control by a          security administrator using the View-Based Access          Control Model (RFC 2575, VACM) for tables in which          multiple users may need to create or          modify entries independently, the initial index is used as          an 'owner index'.  Such an initial index has a syntax of          SnmpAdminString and can thus be trivially mapped to aQuittek & White             Standards Track                    [Page 87]

RFC 4560                       REMOPS MIB                      June 2006          securityName or groupName defined in VACM, in          accordance with a security policy.          When used in conjunction with such a security policy all          entries in the table belonging to a particular user (or          group) will have the same value for this initial index.          For a given user's entries in a particular table, the          object identifiers for the information in these entries          will have the same subidentifiers (except for the          'column' subidentifier) up to the end of the encoded          owner index.  To configure VACM to permit access to this          portion of the table, one would create          vacmViewTreeFamilyTable entries with the value of          vacmViewTreeFamilySubtree including the owner index          portion, and vacmViewTreeFamilyMask 'wildcarding' the          column subidentifier.  More elaborate configurations          are possible."       ::= { lookupCtlEntry 1 }    lookupCtlOperationName OBJECT-TYPE       SYNTAX      SnmpAdminString (SIZE(0..32))       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION           "The name of a lookup operation.  This is locally unique,           within the scope of an lookupCtlOwnerIndex."       ::= { lookupCtlEntry 2 }    lookupCtlTargetAddressType OBJECT-TYPE       SYNTAX      InetAddressType       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "Specifies the type of address for performing a           lookup operation for a symbolic host name or for a host           address from a remote host.           Specification of dns(16) as the value for this object           means that a function such as, for example, getaddrinfo()           or gethostbyname() should be performed to return one or           more numeric addresses.  Use of a value of either ipv4(1)           or ipv6(2) means that a functions such as, for example,           getnameinfo() or gethostbyaddr() should be used to return           the symbolic names associated with a host."       DEFVAL { unknown }       ::= { lookupCtlEntry 3 }Quittek & White             Standards Track                    [Page 88]

RFC 4560                       REMOPS MIB                      June 2006    lookupCtlTargetAddress OBJECT-TYPE       SYNTAX      InetAddress       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "Specifies the address used for a resolver lookup at a           remote host.  The corresponding lookupCtlTargetAddressType           objects determines its type, as well as the function           that can be requested.           A value for this object MUST be set prior to           transitioning its corresponding lookupCtlEntry to           active(1) via lookupCtlRowStatus."       ::= { lookupCtlEntry 4 }    lookupCtlOperStatus OBJECT-TYPE       SYNTAX      INTEGER {                      enabled(1),    -- operation is active                      notStarted(2), -- operation has not started                      completed(3)   -- operation is done                   }       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "Reflects the operational state of an lookupCtlEntry:              enabled(1)    - Operation is active.              notStarted(2) - Operation has not been enabled.              completed(3)  - Operation has been completed.            An operation is automatically enabled(1) when its            lookupCtlRowStatus object is transitioned to active(1)            status.  Until this occurs, lookupCtlOperStatus MUST            report a value of notStarted(2).  After the lookup            operation is completed (success or failure), the value            for lookupCtlOperStatus MUST be transitioned to            completed(3)."       ::= { lookupCtlEntry 5 }    lookupCtlTime OBJECT-TYPE       SYNTAX      Unsigned32       UNITS       "milliseconds"       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "Reports the number of milliseconds that a lookup           operation required to be completed at a remote host.           Completed means operation failure as well asQuittek & White             Standards Track                    [Page 89]

RFC 4560                       REMOPS MIB                      June 2006           success."       ::= { lookupCtlEntry 6 }    lookupCtlRc OBJECT-TYPE       SYNTAX      Integer32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "The system-specific return code from a lookup           operation.  All implementations MUST return a value           of 0 for this object when the remote lookup           operation succeeds.  A non-zero value for this           objects indicates failure.  It is recommended that           implementations return the error codes that are           generated by the lookup function used."       ::= { lookupCtlEntry 7 }    lookupCtlRowStatus OBJECT-TYPE       SYNTAX      RowStatus       MAX-ACCESS  read-create       STATUS      current       DESCRIPTION           "This object allows entries to be created and deleted           in the lookupCtlTable.           A remote lookup operation is started when an           entry in this table is created via an SNMP set           request and the entry is activated.  This           occurs by setting the value of this object           to CreateAndGo(4) during row creation or           by setting this object to active(1) after           the row is created.           A value MUST be specified for lookupCtlTargetAddress           prior to the acceptance of a transition to active(1) state.           A remote lookup operation starts when its entry           first becomes active(1).  Transitions in and           out of active(1) state have no effect on the           operational behavior of a remote lookup           operation, with the exception that deletion of           an entry in this table by setting its RowStatus           object to destroy(6) will stop an active           remote lookup operation.           The operational state of a remote lookup operation           can be determined by examination of its           lookupCtlOperStatus object."       REFERENCEQuittek & White             Standards Track                    [Page 90]

RFC 4560                       REMOPS MIB                      June 2006           "See definition of RowStatus inRFC 2579,           'Textual Conventions for SMIv2.'"       ::= { lookupCtlEntry 8 }   -- Lookup Results Table    lookupResultsTable OBJECT-TYPE       SYNTAX      SEQUENCE OF LookupResultsEntry       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION           "Defines the Lookup Results Table for providing           the capability of determining the results of a           operation at a remote host.           One or more entries are added to the           lookupResultsTable when a lookup operation,           as reflected by an lookupCtlEntry, is completed           successfully.  All entries related to a           successful lookup operation MUST be added           to the lookupResultsTable at the same time           that the associating lookupCtlOperStatus           object is transitioned to completed(2).           The number of entries added depends on the           results determined for a particular lookup           operation.  All entries associated with an           lookupCtlEntry are removed when the           lookupCtlEntry is deleted.           A remote host can be multi-homed and have more than one IP           address associated with it (returned by lookup function),           or it can have more than one symbolic name (returned           by lookup function).           A function such as, for example, getnameinfo() or           gethostbyaddr() is called with a host address as its           parameter and is used primarily to determine a symbolic           name to associate with the host address.  Entries in the           lookupResultsTable MUST be made for each host name           returned.  If the function identifies an 'official host           name,' then this symbolic name MUST be assigned a           lookupResultsIndex of 1.           A function such as, for example, getaddrinfo() or           gethostbyname() is called with a symbolic host name and is           used primarily to retrieve a host address.  The entriesQuittek & White             Standards Track                    [Page 91]

RFC 4560                       REMOPS MIB                      June 2006           MUST be stored in the order that they are retrieved from           the lookup function.  lookupResultsIndex 1 MUST be           assigned to the first entry."      ::= { lookupObjects 4 }    lookupResultsEntry OBJECT-TYPE       SYNTAX      LookupResultsEntry       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION           "Defines an entry in the lookupResultsTable.  The           first two index elements identify the           lookupCtlEntry that a lookupResultsEntry belongs           to.  The third index element selects a single           lookup operation result."       INDEX {                lookupCtlOwnerIndex,                lookupCtlOperationName,                lookupResultsIndex             }       ::= { lookupResultsTable 1 }    LookupResultsEntry ::=       SEQUENCE {           lookupResultsIndex        Unsigned32,           lookupResultsAddressType  InetAddressType,           lookupResultsAddress      InetAddress        }    lookupResultsIndex OBJECT-TYPE       SYNTAX      Unsigned32 (1..'ffffffff'h)       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION           "Entries in the lookupResultsTable are created when           the result of a lookup operation is determined.           Entries MUST be stored in the lookupResultsTable in           the order that they are retrieved.  Values assigned           to lookupResultsIndex MUST start at 1 and increase           consecutively."       ::= { lookupResultsEntry 1 }    lookupResultsAddressType OBJECT-TYPE       SYNTAX      InetAddressType       MAX-ACCESS  read-only       STATUS      current       DESCRIPTIONQuittek & White             Standards Track                    [Page 92]

RFC 4560                       REMOPS MIB                      June 2006           "Indicates the type of result of a remote lookup           operation.  A value of unknown(0) implies either that           the operation hasn't been started or that           it has failed."       ::= { lookupResultsEntry 2 }    lookupResultsAddress OBJECT-TYPE       SYNTAX      InetAddress       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "Reflects a result for a remote lookup operation           as per the value of lookupResultsAddressType.           The address type (InetAddressType) that relates to           this object is specified by the corresponding value           of lookupResultsAddress."       ::= { lookupResultsEntry 3 }    -- Conformance information    -- Compliance statements    lookupCompliances OBJECT IDENTIFIER ::= { lookupConformance 1 }    lookupGroups      OBJECT IDENTIFIER ::= { lookupConformance 2 }    -- Compliance statements    lookupCompliance MODULE-COMPLIANCE       STATUS  current       DESCRIPTION               "The compliance statement for SNMP entities that               fully implement the DISMAN-NSLOOKUP-MIB."       MODULE  -- this module           MANDATORY-GROUPS { lookupGroup }           OBJECT lookupMaxConcurrentRequests           MIN-ACCESS  read-only           DESCRIPTION               "The agent is not required to support set               operations to this object."           OBJECT lookupPurgeTime           MIN-ACCESS  read-only           DESCRIPTION               "The agent is not required to support a set               operation to this object."Quittek & White             Standards Track                    [Page 93]

RFC 4560                       REMOPS MIB                      June 2006       ::= { lookupCompliances 1 }    lookupMinimumCompliance MODULE-COMPLIANCE       STATUS  current       DESCRIPTION               "The minimum compliance statement for SNMP entities               that implement the minimal subset of the               DISMAN-NSLOOKUP-MIB.  Implementors might choose this               subset for small devices with limited resources."       MODULE  -- this module           MANDATORY-GROUPS { lookupGroup }           OBJECT lookupMaxConcurrentRequests           MIN-ACCESS  read-only           DESCRIPTION               "The agent is not required to support set               operations to this object."           OBJECT lookupPurgeTime           MIN-ACCESS  read-only           DESCRIPTION               "The agent is not required to support a set               operation to this object."           OBJECT lookupCtlRowStatus           MIN-ACCESS  read-only           DESCRIPTION               "Write access is not required.  If write access is               not supported, then at least one entry in the               lookupCtlTable MUST be established already when the SNMP               agent starts offering access to the NSLOOKUP-MIB module.               If, in such a case, only a single entry is offered, then               it is RECOMMENDED that this entry use strings with a               length of 0 for both of its two index objects."       ::= { lookupCompliances 2 }    -- MIB groupings    lookupGroup OBJECT-GROUP      OBJECTS {                lookupMaxConcurrentRequests,                lookupPurgeTime,                lookupCtlOperStatus,                lookupCtlTargetAddressType,                lookupCtlTargetAddress,                lookupCtlTime,                lookupCtlRc,                lookupCtlRowStatus,Quittek & White             Standards Track                    [Page 94]

RFC 4560                       REMOPS MIB                      June 2006                lookupResultsAddressType,                lookupResultsAddress              }      STATUS  current      DESCRIPTION          "The group of objects that constitute the remote          Lookup operation."       ::= { lookupGroups 1 }   END5.  Security Considerations   There are a number of management objects defined in the three MIB   modules with a MAX-ACCESS clause of read-write and/or read-create.   Such objects may be considered sensitive or vulnerable in some   network environments.  The support for SET operations in a non-secure   environment without proper protection can have a negative effect on   network operations.  These are the tables and objects and their   sensitivity/vulnerability:   o  pingMaxConcurrentRequests   o  traceRouteMaxConcurrentRequests   o  lookupMaxConcurrentRequests      The MIB modules limit their maximum numbers of concurrent requests      by the values of these objects.  Unauthorized access to them may      lead to an overload of the managed node and to a disruption of      other functions of the managed node.   o  pingCtlTable   o  traceRouteCtlTable   o  lookupCtlTable      All objects in entries of these tables (except index objects) have      a MAX-ACCESS clause of read-create.  Unauthorized access to these      objects can disturb the measurements controlled by the tables.      Also, the functions offered by the MIB modules can be misused for      illegal data retrieval and for attacking other systems by floods      of ping probes, traceroute probes or lookup requests,      respectively.   In general, all three, the ping, traceroute, and lookup functions,   when used excessively are considered a form of system attack.  In the   case of ping, sending a system request too often can negatively   effect its performance and attempting to connect to what is supposed   to be an unused port can be very unpredictable.  Excessive use of the   traceroute capability can, like ping, negatively affect system   performance.  The same applies to excessive use of the lookup   service, particularly if the lookup cannot be resolved locally.  InQuittek & White             Standards Track                    [Page 95]

RFC 4560                       REMOPS MIB                      June 2006   insecure environments, it is RECOMMENDED that the MIBs defined within   this memo not be supported.   o  lookupPurgeTime      Unauthorized access to this object can lead to the deletion of      results of lookup operations before they are read by a management      system, if the object is set to 0 or small values close to 0.  If      the object is set to very high values, unauthorized access can      lead to a high consumption of resources for storing lookup      results.   Some of the readable objects in this MIB module (i.e., objects with a   MAX-ACCESS other than not-accessible) may be considered sensitive or   vulnerable in some network environments.  It is thus important to   control even GET and/or NOTIFY access to these objects and possibly   to even encrypt the values of these objects when sending them over   the network via SNMP.  However, the only information that can be   disclosed without encryption is the configuration and results of   measurements that are performed by implementations of the MIB   modules.   To facilitate the provisioning of access control by a security   administrator using the View-Based Access Control Model (VACM),   defined inRFC 3415 [RFC3415], for tables in which multiple users may   need to create or modify entries independently, the initial index is   used as an "owner index."  Such an initial index has a syntax of   SnmpAdminString and can thus be trivially mapped to a securityName or   groupName defined in VACM, in accordance with a security policy.   All entries in related tables belonging to a particular user will   have the same value for this initial index.  For a given user's   entries in a particular table, the object identifiers for the   information in these entries will have the same subidentifiers   (except for the "column" subidentifier) up to the end of the encoded   owner index.  To configure VACM to permit access to this portion of   the table, one would create vacmViewTreeFamilyTable entries with the   value of vacmViewTreeFamilySubtree including the owner index portion,   and vacmViewTreeFamilyMask 'wildcarding' the column subidentifier.   More elaborate configurations are possible.  The VACM access control   mechanism described above provides control.   SNMP versions prior to SNMPv3 did not include adequate security.   Even if the network itself is secure (for example by using IPSec),   even then, there is no control as to who on the secure network isQuittek & White             Standards Track                    [Page 96]

RFC 4560                       REMOPS MIB                      June 2006   allowed to access and GET/SET (read/change/create/delete) the objects   in this MIB module.   It is RECOMMENDED that implementers consider the security features as   provided by the SNMPv3 framework (see[RFC3410], section 8),   including full support for the SNMPv3 cryptographic mechanisms (for   authentication and privacy).   Further, deployment of SNMP versions prior to SNMPv3 is NOT   RECOMMENDED.  Instead, it is RECOMMENDED to deploy SNMPv3 and to   enable cryptographic security.  It is then a customer/operator   responsibility to ensure that the SNMP entity giving access to an   instance of this MIB module is properly configured to give access to   the objects only to those principals (users) that have legitimate   rights to indeed GET or SET (change/create/delete) them.6.  Acknowledgements   This document is a product of the DISMAN Working Group.  Thanks to   Eduardo Cardona for suggesting the minimum compliance statements and   to Juergen Schoenwaelder for the very detailed and constructive MIB   review.7.  References7.1.  Normative References   [RFC2119]   Bradner, S., "Key words for use in RFCs to Indicate               Requirement Levels",BCP 14,RFC 2119, March 1997.   [RFC2578]   McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J.,               Rose, M., and S. Waldbusser, "Structure of Management               Information Version 2 (SMIv2)", STD 58,RFC 2578, April               1999.   [RFC2579]   McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J.,               Rose, M., and S. Waldbusser, "Textual Conventions for               SMIv2", STD 58,RFC 2579, April 1999.   [RFC2580]   McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J.,               Rose, M., and S. Waldbusser, "Conformance Statements for               SMIv2", STD 58,RFC 2580, April 1999.   [RFC2863]   McCloghrie, K. and F. Kastenholz, "The Interfaces Group               MIB",RFC 2863, June 2000.Quittek & White             Standards Track                    [Page 97]

RFC 4560                       REMOPS MIB                      June 2006   [RFC3411]   Harrington, D., Presuhn, R., and B. Wijnen, "An               Architecture for Describing Simple Network Management               Protocol (SNMP) Management Frameworks", STD 62,RFC 3411,               December 2002.   [RFC4001]   Daniele, M., Haberman, B., Routhier, S., and J.               Schoenwaelder, "Textual Conventions for Internet Network               Addresses",RFC 4001, February 2005.7.2.  Informative References   [RFC792]    Postel, J., "Internet Control Message Protocol", STD 5,RFC 792, September 1981.   [RFC862]    Postel, J., "Echo Protocol", STD 20,RFC 862, May 1983.   [RFC1812]   Baker, F., "Requirements for IP Version 4 Routers",RFC1812, June 1995.   [RFC2474]   Nichols, K., Blake, S., Baker, F., and D. Black,               "Definition of the Differentiated Services Field (DS               Field) in the IPv4 and IPv6 Headers",RFC 2474, December               1998.   [RFC3260]   Grossman, D., "New Terminology and Clarifications for               Diffserv",RFC 3260, April 2002.   [RFC3410]   Case, J., Mundy, R., Partain, D. and B. Stewart,               "Introduction and Applicability Statements for Internet-               Standard Management Framework",RFC 3410, December 2002.   [RFC3415]   Wijnen, B., Presuhn, R., and K. McCloghrie, "View-based               Access Control Model (VACM) for the Simple Network               Management Protocol (SNMP)", STD 62,RFC 3415, December               2002.Quittek & White             Standards Track                    [Page 98]

RFC 4560                       REMOPS MIB                      June 2006Authors' Addresses   Juergen Quittek   NEC Europe Ltd.   Network Laboratories   Kurfuersten-Anlage 36   69115 Heidelberg   Germany   Phone: +49 6221 4342-115   EMail: quittek@netlab.nec.de   Kenneth D. White   Dept. BRQA/Bldg. 501/G114   IBM Corporation   P.O.Box 12195   3039 Cornwallis   Research Triangle Park, NC 27709, USA   EMail: wkenneth@us.ibm.comQuittek & White             Standards Track                    [Page 99]

RFC 4560                       REMOPS MIB                      June 2006Full Copyright Statement   Copyright (C) The Internet Society (2006).   This document is subject to the rights, licenses and restrictions   contained inBCP 78, and except as set forth therein, the authors   retain all their rights.   This document and the information contained herein are provided on an   "AS IS" basis and THE CONTRIBUTOR, THE ORGANIZATION HE/SHE REPRESENTS   OR IS SPONSORED BY (IF ANY), THE INTERNET SOCIETY AND THE INTERNET   ENGINEERING TASK FORCE DISCLAIM ALL WARRANTIES, EXPRESS OR IMPLIED,   INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE   INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED   WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.Intellectual Property   The IETF takes no position regarding the validity or scope of any   Intellectual Property Rights or other rights that might be claimed to   pertain to the implementation or use of the technology described in   this document or the extent to which any license under such rights   might or might not be available; nor does it represent that it has   made any independent effort to identify any such rights.  Information   on the procedures with respect to rights in RFC documents can be   found inBCP 78 andBCP 79.   Copies of IPR disclosures made to the IETF Secretariat and any   assurances of licenses to be made available, or the result of an   attempt made to obtain a general license or permission for the use of   such proprietary rights by implementers or users of this   specification can be obtained from the IETF on-line IPR repository athttp://www.ietf.org/ipr.   The IETF invites any interested party to bring to its attention any   copyrights, patents or patent applications, or other proprietary   rights that may cover technology that may be required to implement   this standard.  Please address the information to the IETF at   ietf-ipr@ietf.org.Acknowledgement   Funding for the RFC Editor function is provided by the IETF   Administrative Support Activity (IASA).Quittek & White             Standards Track                   [Page 100]