Comparative Study
.1998 Nov;45(3):332-6.
doi: 10.1002/(sici)1097-0304(199811)45:3<332::aid-ccd27>3.0.co;2-r.

Neointimal response following rotational atherectomy compared to balloon angioplasty in a porcine model of coronary in-stent restenosis

Affiliations
Comparative Study

Neointimal response following rotational atherectomy compared to balloon angioplasty in a porcine model of coronary in-stent restenosis

C J McKenna et al. Cathet Cardiovasc Diagn.1998 Nov.

Abstract

In-stent restenosis remains a clinical therapeutic challenge. Rotational atherectomy (RA) is an attractive treatment option as it may cause less vascular injury than balloon angioplasty (BA) and, therefore, limit further neointimal response. In an animal model of coronary in-stent restenosis, thermal injury and stenting created neointima (old NI). The treatment of in-stent restenosis with either BA (n = 9) or RA (n = 11) also generated neointima (new NI). The average areas (mm2) of old NI in the BA and RA groups were similar (3.77 +/- 0.40 vs. 3.67 +/- 0.53; P = 0.32). However, new NI formed after treatment of in-stent restenosis was significantly less in the RA as compared to the BA group (0.33 +/- 0.12 vs. 0.73 +/- 36, P < 0.01). In this porcine coronary artery model of in-stent restenosis, treatment with rotational atherectomy resulted in significantly less recurrent neointimal hyperplasia than balloon angioplasty. This animal study, thus, provides a rationale for the clinical use of rotablation in the treatment of in-stent restenosis.

PubMed Disclaimer

Similar articles

See all similar articles

Cited by

Publication types

MeSH terms

Related information

LinkOut - more resources

Full text links
Wiley full text link Wiley
Cite
Send To

NCBI Literature Resources

MeSHPMCBookshelfDisclaimer

The PubMed wordmark and PubMed logo are registered trademarks of the U.S. Department of Health and Human Services (HHS). Unauthorized use of these marks is strictly prohibited.


[8]ページ先頭

©2009-2025 Movatter.jp