Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study
- PMID:9801213
- DOI: 10.2106/00004623-199810000-00006
Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study
Abstract
There is an increasing recognition that, in the long term, total joint replacement may be associated with adverse local and remote tissue responses that are mediated by the degradation products of prosthetic materials. Particular interest has centered on the metal-degradation products of total joint replacements because of the known toxicities of the metal elements that make up the alloys used in the implants. We measured the concentrations of titanium, aluminum, cobalt, and chromium in the serum and the concentration of chromium in the urine of seventy-five patients during a three-year prospective, longitudinal study. Twenty patients had had a so-called hybrid total hip replacement (insertion of a modular cobalt-alloy femoral stem and head with cement and a titanium acetabular cup without cement), fifteen had had insertion of an extensively porous-coated cobalt-alloy stem with a cobalt-alloy head and a titanium-alloy socket without cement, and twenty had had insertion of a proximally porous-coated titanium-alloy stem with a cobalt-alloy head and a titanium socket without cement. The remaining twenty patients did not have an implant and served as controls. The results of our study showed that, thirty-six months postoperatively, patients who have a well functioning prosthesis with components containing titanium have as much as a threefold increase in the concentration of titanium in the serum and those who have a well functioning prosthesis with cobalt-alloy components have as much as a fivefold and an eightfold increase in the concentrations of chromium in the serum and urine, respectively. The predominant source of the disseminated chromium-degradation products is probably the modular head-neck junction and may be a function of the geometry of the coupling. Passive dissolution of extensively porous-coated cobalt-alloy stems was not found to be a dominant mode of metal release.
Clinical relevance: Increased concentrations of circulating metal-degradation products derived from orthopaedic implants may have deleterious biological effects over the long term that warrant investigation. This is a particularly timely concern because of recent clinical trends, including the reintroduction of metal-on-metal bearing surfaces and the increasing popularity of extensively porous-coated devices with large surface areas of exposed metal. Accurate monitoring of the concentrations of metal in the serum and urine after total hip replacement also can provide insights into the mechanisms of metal release. Our findings suggest that fretting corrosion at the head-neck coupling is an important source of metal release that can lead to increased concentrations of chromium in the serum. Determinations of the concentrations of metal in the serum and urine may be useful in the diagnosis of patients who are symptomatic after a total joint replacement as increased levels are indicative of at least one mode of mechanical dysfunction (for example, fretting corrosion) of the device.
Similar articles
- Ten-year outcome of serum metal ion levels after primary total hip arthroplasty: a concise follow-up of a previous report*.Levine BR, Hsu AR, Skipor AK, Hallab NJ, Paprosky WG, Galante JO, Jacobs JJ.Levine BR, et al.J Bone Joint Surg Am. 2013 Mar 20;95(6):512-8. doi: 10.2106/JBJS.L.00471.J Bone Joint Surg Am. 2013.PMID:23515985Free PMC article.Clinical Trial.
- Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck.Cooper HJ, Urban RM, Wixson RL, Meneghini RM, Jacobs JJ.Cooper HJ, et al.J Bone Joint Surg Am. 2013 May 15;95(10):865-72. doi: 10.2106/JBJS.L.01042.J Bone Joint Surg Am. 2013.PMID:23677352Free PMC article.
- Comparison of whole-blood metal ion levels in four types of metal-on-metal large-diameter femoral head total hip arthroplasty: the potential influence of the adapter sleeve.Lavigne M, Belzile EL, Roy A, Morin F, Amzica T, Vendittoli PA.Lavigne M, et al.J Bone Joint Surg Am. 2011 May;93 Suppl 2:128-36. doi: 10.2106/JBJS.J.01885.J Bone Joint Surg Am. 2011.PMID:21543702
- Systemic toxicity related to metal hip prostheses.Bradberry SM, Wilkinson JM, Ferner RE.Bradberry SM, et al.Clin Toxicol (Phila). 2014 Sep-Oct;52(8):837-47. doi: 10.3109/15563650.2014.944977. Epub 2014 Aug 16.Clin Toxicol (Phila). 2014.PMID:25132471Review.
- Bimodular femoral stems in primary total hip arthroplasty.Zajc J, Fokter SK.Zajc J, et al.Expert Rev Med Devices. 2023 Jul-Dec;20(12):1051-1064. doi: 10.1080/17434440.2023.2264177. Epub 2023 Nov 24.Expert Rev Med Devices. 2023.PMID:37753590Review.
Cited by
- An alumina toughened zirconia composite for dental implant application: in vivo animal results.Schierano G, Mussano F, Faga MG, Menicucci G, Manzella C, Sabione C, Genova T, von Degerfeld MM, Peirone B, Cassenti A, Cassoni P, Carossa S.Schierano G, et al.Biomed Res Int. 2015;2015:157360. doi: 10.1155/2015/157360. Epub 2015 Apr 6.Biomed Res Int. 2015.PMID:25945324Free PMC article.
- Long-term follow-up and metal ion trend of patients with metal-on-metal total hip arthroplasty.Bernstein M, Desy NM, Petit A, Zukor DJ, Huk OL, Antoniou J.Bernstein M, et al.Int Orthop. 2012 Sep;36(9):1807-12. doi: 10.1007/s00264-012-1570-1. Epub 2012 Jun 9.Int Orthop. 2012.PMID:22678122Free PMC article.
- A review of the biologic effects of spine implant debris: Fact from fiction.Hallab NJ.Hallab NJ.SAS J. 2009 Dec 1;3(4):143-60. doi: 10.1016/j.esas.2009.11.005. eCollection 2009.SAS J. 2009.PMID:25802640Free PMC article.
- Cancer following hip and knee arthroplasty: record linkage study.Goldacre MJ, Wotton CJ, Seagroatt V, Yeates D.Goldacre MJ, et al.Br J Cancer. 2005 Apr 11;92(7):1298-301. doi: 10.1038/sj.bjc.6602511.Br J Cancer. 2005.PMID:15812477Free PMC article.
- No generally increased risk of cancer after total hip arthroplasty performed due to osteoarthritis.Hailer NP, Garland A, Gordon M, Kärrholm J, Sköldenberg O, Eriksson N, Garmo H, Holmberg L.Hailer NP, et al.Int J Cancer. 2020 Jul 1;147(1):76-83. doi: 10.1002/ijc.32711. Epub 2019 Nov 5.Int J Cancer. 2020.PMID:31595487Free PMC article.
Publication types
MeSH terms
Substances
Related information
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical