Clinical Trial
.1996 Nov-Dec;19(6):411-7.
doi: 10.1007/BF02577629.

Intraarterial pressure gradients after randomized angioplasty or stenting of iliac artery lesions. Dutch Iliac Stent Trial Study Group

Affiliations
Clinical Trial

Intraarterial pressure gradients after randomized angioplasty or stenting of iliac artery lesions. Dutch Iliac Stent Trial Study Group

E Tetteroo et al. Cardiovasc Intervent Radiol.1996 Nov-Dec.

Abstract

Purpose: To determine initial technical results of percutaneous transluminal angioplasty (PTA) and stent procedures in the iliac artery, mean intraarterial pressure gradients were recorded before and after each procedure.

Methods: We randomly assigned 213 patients with typical intermittent claudication to primary stent placement (n = 107) or primary PTA (n = 106), with subsequent stenting in the case of a residual mean pressure gradient of > 10 mmHg (n = 45). Eligibility criteria included angiographic iliac artery stenosis (> 50% diameter reduction) and/or a peak systolic velocity ratio > 2.5 on duplex examination. Mean intraarterial pressures were simultaneously recorded above and below the lesion, at rest and also during vasodilatation in the case of a resting gradient < or = 10 mmHg.

Results: Pressure gradients in the primary stent group were 14.9 +/- 10.4 mmHg before and 2.9 +/- 3.5 mmHg after stenting. Pressure gradients in the primary PTA group were 17.3 +/- 11.3 mmHg pre-PTA, 4.2 +/- 5.4 mmHg post-PTA, and 2.5 +/- 2.8 mmHg after selective stenting. Compared with primary stent placement, PTA plus selective stent placement avoided application of a stent in 63% (86/137) of cases, resulting in a considerable cost saving.

Conclusion: Technical results of primary stenting and PTA plus selective stenting are similar in terms of residual pressure gradients.

PubMed Disclaimer

Similar articles

See all similar articles

Cited by

See all "Cited by" articles

References

    1. Cardiovasc Intervent Radiol. 1992 Sep-Oct;15(5):291-7 - PubMed
    1. Surg Clin North Am. 1992 Aug;72(4):941-57 - PubMed
    1. J Vasc Surg. 1984 Jan;1(1):215-23 - PubMed
    1. Circulation. 1991 Feb;83(2 Suppl):I6-11 - PubMed
    1. Radiology. 1990 Mar;174(3 Pt 1):741-5 - PubMed

Publication types

MeSH terms

Related information

LinkOut - more resources

Full text links
Springer full text link Springer
Cite
Send To

NCBI Literature Resources

MeSHPMCBookshelfDisclaimer

The PubMed wordmark and PubMed logo are registered trademarks of the U.S. Department of Health and Human Services (HHS). Unauthorized use of these marks is strictly prohibited.


[8]ページ先頭

©2009-2025 Movatter.jp