Movatterモバイル変換


[0]ホーム

URL:


Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
Thehttps:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

NIH NLM Logo
Log inShow account info
Access keysNCBI HomepageMyNCBI HomepageMain ContentMain Navigation
pubmed logo
Advanced Clipboard
User Guide

Full text links

Atypon full text link Atypon Free PMC article
Full text links

Actions

Share

.2018 Dec;46(12):4965-4973.
doi: 10.1177/0300060518787718. Epub 2018 Oct 25.

Clinical application and importance of one-step human CYP2C19 genotype detection

Affiliations

Clinical application and importance of one-step human CYP2C19 genotype detection

Ling-Jie Zheng et al. J Int Med Res.2018 Dec.

Abstract

Background: To directly achieve cytochrome P450 2C19 gene ( CYP2C19) classification using one-step real-time fluorescent PCR detection and to verify the capabilities of this method with nucleic acid extracted from whole blood samples.

Methods: A human CYP2C19 genotyping kit based on one-step real-time fluorescent PCR detection was used to analyze whole blood or genomic DNA samples. This method was compared with pyrosequencing and another quantitative (q)PCR kit for its accuracy, repeatability, detection range analysis, sensitivity, specificity, and anti-interference analysis.

Results: The one-step real-time PCR method achieved a 100% accuracy rate compared with pyrosequencing and the other qPCR kit. When detecting different concentrations of known genes, concentrations of each sample ranging from 0.2 to 125 ng/µL could be correctly detected. The genotypes of samples treated with anticoagulants, including EDTA and sodium citrate, and chyle blood samples could be correctly detected.

Conclusion: The one-step detection method demonstrated high accuracy and a wide detection range. It also had high levels of repeatability, sensitivity, and specificity for the assessment of genomic DNA test samples.

Keywords: CYP2C19; Real-time fluorescent PCR; genotype detection; one-step detection.

PubMed Disclaimer

Figures

Figure 1.
Figure 1.
Sample amplification curves for the CYP2C19*2 genotype (a) and CYP2C19*3 genotype (b).
See this image and copyright information in PMC

Similar articles

See all similar articles

Cited by

References

    1. Weinshilboum RM, Wang L. Pharmacogenomics: precision medicine and drug response. Mayo Clin Proc 2017; 92: 1711–1722. - PMC - PubMed
    1. Jones S. Welcome to the 19th volume of Pharmacogenomics. Pharmacogenomics 2018; 19: 1–2. - PubMed
    1. Mooney SD. Progress towards the integration of pharmacogenomics in practice. Hum Genet 2015; 134: 459–465. - PMC - PubMed
    1. Cayre A, Mishellany F, Lagarde N, et al. Comparison of different commercial kits for HER2 testing in breast cancer: looking for the accurate cutoff for amplification. Breast Cancer Res 2007; 9: R64. - PMC - PubMed
    1. https://www.fda.gov/MedicalDevices/default.htm

MeSH terms

Substances

Related information

LinkOut - more resources

Full text links
Atypon full text link Atypon Free PMC article
Cite
Send To

NCBI Literature Resources

MeSHPMCBookshelfDisclaimer

The PubMed wordmark and PubMed logo are registered trademarks of the U.S. Department of Health and Human Services (HHS). Unauthorized use of these marks is strictly prohibited.


[8]ページ先頭

©2009-2025 Movatter.jp