Movatterモバイル変換


[0]ホーム

URL:


Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
Thehttps:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

NIH NLM Logo
Log inShow account info
Access keysNCBI HomepageMyNCBI HomepageMain ContentMain Navigation
pubmed logo
Advanced Clipboard
User Guide

Full text links

Atypon full text link Atypon
Full text links

Actions

Share

Meta-Analysis
.2016 May;206(5):W73-82.
doi: 10.2214/AJR.15.15336. Epub 2016 Mar 24.

Ultrasound for the Diagnosis of Biliary Atresia: A Meta-Analysis

Affiliations
Meta-Analysis

Ultrasound for the Diagnosis of Biliary Atresia: A Meta-Analysis

Luyao Zhou et al. AJR Am J Roentgenol.2016 May.

Abstract

Objective: The purpose of this meta-analysis was to summarize the evidence on the accuracy of various ultrasound findings for excluding a diagnosis of biliary atresia.

Materials and methods: We searched MEDLINE and the Web of Science databases for the period from January 1990 to May 2015. To be included, studies had to satisfy two criteria. First, the data needed to include 2 × 2 contingency data on the diagnostic accuracy of ultrasound in identifying biliary atresia in at least 10 patients with and 10 patients without disease. Second, the study needed to use surgery or biopsy for biliary atresia and surgery, biopsy, clinical follow-up, or some combination of the three as the reference standard for the exclusion of biliary atresia. The methodologic quality of each study was assessed with version 2 of the Quality Assessment of Diagnostic Accuracy Studies tool. Estimated sensitivity and specificity of each ultrasound characteristic were calculated using a random-effects model.

Results: Twenty-three studies published during 1998-2015 were included. Summary sensitivity and specificity were 0.85 (95% CI, 0.76-0.91) and 0.92 (95% CI, 0.81-0.97), respectively, for gallbladder abnormalities in 19 studies; 0.74 (95% CI, 0.61-0.84) and 0.97 (95% CI, 0.95-0.99), respectively, for triangular cord sign in 20 studies; and 0.95 (95% CI, 0.70-0.99) and 0.89 (95% CI, 0.79-0.94), respectively, for the combination of the triangular cord sign and gallbladder abnormalities in five studies. Subgroup analysis of an absent gallbladder in 10 studies yielded a summary specificity of 0.99 (95% CI, 0.93-1.00).

Conclusion: The triangular cord sign and gallbladder abnormalities are the two most accurate and widely accepted ultrasound characteristics for diagnosing or excluding biliary atresia. Other ultrasound characteristics are less valuable for diagnosis or exclusion of biliary atresia.

Keywords: biliary atresia; gallbladder; pediatrics; triangular cord sign; ultrasound.

PubMed Disclaimer

Similar articles

See all similar articles

Cited by

See all "Cited by" articles

Publication types

MeSH terms

Related information

LinkOut - more resources

Full text links
Atypon full text link Atypon
Cite
Send To

NCBI Literature Resources

MeSHPMCBookshelfDisclaimer

The PubMed wordmark and PubMed logo are registered trademarks of the U.S. Department of Health and Human Services (HHS). Unauthorized use of these marks is strictly prohibited.


[8]ページ先頭

©2009-2025 Movatter.jp