.1990 Jul;50(1):40-3; discussion 43-4.
doi: 10.1016/0003-4975(90)90080-p.

Four years' experience with fibrin sealant in thoracic and cardiovascular surgery

Affiliations

Four years' experience with fibrin sealant in thoracic and cardiovascular surgery

T L Matthew et al. Ann Thorac Surg.1990 Jul.

Abstract

A single-donor fibrin sealant system was used in 689 thoracic and cardiovascular surgical procedures over the 4-year period between April 1, 1985, and March 31, 1989. An excellent overall success rate (646/689, 94% effective) was achieved with specific applications, including reduction of leakage of air (29/33, 88% effective), blood (595/634, 94% effective), and fluid (14/14, 100% effective), as well as positioning of anatomical structures such as coronary bypass grafts (8/8, 100% effective). Application methods included use of spray bottles (477/497, 96% effective), syringes (165/186, 89% effective), and a Silastic cannula through the flexible fiber-optic bronchoscope (4/6, 67% effective). The system was used in a wide variety of cardiac, pulmonary, esophageal, and vascular procedures to seal staple lines, suture lines, anastomoses, conduits, fistulas, and raw surfaces. No complications with this single-donor system secondary to blood-borne disease have been documented. Overall infection occurred at a nominal rate (16/689, 2%). Thus, fibrin sealant has been a useful tool to control the leakage of air, blood, and fluid during a wide variety of thoracic and cardiovascular procedures and may be of benefit to other surgeons.

PubMed Disclaimer

Similar articles

See all similar articles

Cited by

See all "Cited by" articles

MeSH terms

Substances

LinkOut - more resources

Full text links
Elsevier Science full text link Elsevier Science
Cite
Send To

NCBI Literature Resources

MeSHPMCBookshelfDisclaimer

The PubMed wordmark and PubMed logo are registered trademarks of the U.S. Department of Health and Human Services (HHS). Unauthorized use of these marks is strictly prohibited.


[8]ページ先頭

©2009-2025 Movatter.jp