Movatterモバイル変換


[0]ホーム

URL:


Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
Thehttps:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

NIH NLM Logo
Log inShow account info
Access keysNCBI HomepageMyNCBI HomepageMain ContentMain Navigation
pubmed logo
Advanced Clipboard
User Guide

Full text links

Wolters Kluwer full text link Wolters Kluwer
Full text links

Actions

.2012 Dec;26(12):3204-8.
doi: 10.1519/JSC.0b013e3182736641.

Effect of supportive equipment on force, velocity, and power in the squat

Affiliations

Effect of supportive equipment on force, velocity, and power in the squat

Justin A Blatnik et al. J Strength Cond Res.2012 Dec.

Abstract

The purpose of this investigation was to examine various kinetic and kinematic variables associated with squats without and with the use of a squat suit (SS). No previous investigation has examined the effect of an SS on squat performance. Participants were 8 elite or professional level male powerlifters (height = 178.59 ± 3.5 cm; body mass = 106.8 ± 30.4 kg; age = 25 ± 2.2 years; mean 1 repetition maximum [1RM] =197.7 ± 53 kg). Subjects participated in 3 testing sessions, with the first session involving a 1RM squat without a squat suit (NSS). Sessions 2 and 3 involved a testing session completing 2 trials in the squat at 3 intensities (80, 90, and 100% of 1RM) either without (NSS) or with an SS. The session and order of the intensities were all randomized. Force-time, velocity-time, and power-time graphs were calculated from data from a force plate and 2 linear position transducers attached to the barbell. Peak eccentric force was significantly higher during SS at 100% of 1RM (NSS-100 = 3196.2 ± 470.6, SS-100 = 3369.7 ± 589.9 N). Peak concentric velocity was significantly higher during SS in comparison to NSS at all intensities. Peak concentric power was significantly higher during SS at 80% of 1RM (NSS-80 = 1566.5 ± 388.4 W, SS-80 = 1770.4 ± 483.2 W) and 90% of 1RM (NSS-90 = 1493.1 ± 296.2 W, SS-90 = 1723.8 ± 449.5 W). The current investigation has demonstrated significantly different kinetic and kinematic characteristics between squats without (NSS) and with an SS, which could ultimately aid in enhancing squat performance.

PubMed Disclaimer

MeSH terms

LinkOut - more resources

Full text links
Wolters Kluwer full text link Wolters Kluwer
Cite
Send To

NCBI Literature Resources

MeSHPMCBookshelfDisclaimer

The PubMed wordmark and PubMed logo are registered trademarks of the U.S. Department of Health and Human Services (HHS). Unauthorized use of these marks is strictly prohibited.


[8]ページ先頭

©2009-2026 Movatter.jp