Movatterモバイル変換


[0]ホーム

URL:


Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
Thehttps:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

NIH NLM Logo
Log inShow account info
Access keysNCBI HomepageMyNCBI HomepageMain ContentMain Navigation
pubmed logo
Advanced Clipboard
User Guide

Full text links

Elsevier Science full text link Elsevier Science
Full text links

Actions

.2012 Jan;80(1):1-5.
doi: 10.1016/j.jhin.2011.08.010. Epub 2011 Dec 2.

Potential for aerosolization of Clostridium difficile after flushing toilets: the role of toilet lids in reducing environmental contamination risk

Affiliations

Potential for aerosolization of Clostridium difficile after flushing toilets: the role of toilet lids in reducing environmental contamination risk

E L Best et al. J Hosp Infect.2012 Jan.

Abstract

Background: Toilet facilities in healthcare settings vary widely, but patient toilets are commonly shared and do not have lids. When a toilet is flushed without the lid closed, aerosol production may lead to surface contamination within the toilet environment.

Aim: To substantiate the risks of airborne dissemination of C. difficile following flushing a toilet, in particular when lids are not fitted.

Methods: We performed in-situ testing, using faecal suspensions of C. difficile to simulate the bacterial burden found during disease, to measure C. difficile aerosolization. We also measured the extent of splashing occurring during flushing of two different toilet types commonly used in hospitals.

Findings: C. difficile was recoverable from air sampled at heights up to 25 cm above the toilet seat. The highest numbers of C. difficile were recovered from air sampled immediately following flushing, and then declined 8-fold after 60 min and a further 3-fold after 90 min. Surface contamination with C. difficile occurred within 90 min after flushing, demonstrating that relatively large droplets are released which then contaminate the immediate environment. The mean numbers of droplets emitted upon flushing by the lidless toilets in clinical areas were 15-47, depending on design. C. difficile aerosolization and surrounding environmental contamination occur when a lidless toilet is flushed.

Conclusion: Lidless conventional toilets increase the risk of C. difficile environmental contamination, and we suggest that their use is discouraged, particularly in settings where CDI is common.

Copyright © 2011 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

PubMed Disclaimer

Comment in

Publication types

MeSH terms

Substances

LinkOut - more resources

Full text links
Elsevier Science full text link Elsevier Science
Cite
Send To

NCBI Literature Resources

MeSHPMCBookshelfDisclaimer

The PubMed wordmark and PubMed logo are registered trademarks of the U.S. Department of Health and Human Services (HHS). Unauthorized use of these marks is strictly prohibited.


[8]ページ先頭

©2009-2026 Movatter.jp