.2008 Aug;60(2):320-9.
doi: 10.1002/mrm.21635.

Rapid magnetic resonance quantification on the brain: Optimization for clinical usage

Affiliations
Free article

Rapid magnetic resonance quantification on the brain: Optimization for clinical usage

J B M Warntjes et al. Magn Reson Med.2008 Aug.
Free article

Abstract

A method is presented for rapid simultaneous quantification of the longitudinal T(1) relaxation, the transverse T(2) relaxation, the proton density (PD), and the amplitude of the local radio frequency B(1) field. All four parameters are measured in one single scan by means of a multislice, multiecho, and multidelay acquisition. It is based on a previously reported method, which was substantially improved for routine clinical usage. The improvements comprise of the use of a multislice spin-echo technique, a background phase correction, and a spin system simulation to compensate for the slice-selective RF pulse profile effects. The aim of the optimization was to achieve the optimal result for the quantification of magnetic resonance parameters within a clinically acceptable time. One benchmark was high-resolution coverage of the brain within 5 min. In this scan time the measured intersubject standard deviation (SD) in a group of volunteers was 2% to 8%, depending on the tissue (voxel size = 0.8 x 0.8 x 5 mm). As an example, the method was applied to a patient with multiple sclerosis in whom the diseased tissue could clearly be distinguished from healthy reference values. Additionally it was shown that, using the approach of synthetic MRI, both accurate conventional contrast images as well as quantification maps can be generated based on the same scan.

(c) 2008 Wiley-Liss, Inc.

PubMed Disclaimer

Similar articles

See all similar articles

Cited by

See all "Cited by" articles

Publication types

MeSH terms

LinkOut - more resources

Full text links
Wiley full text link Wiley
Cite
Send To

NCBI Literature Resources

MeSHPMCBookshelfDisclaimer

The PubMed wordmark and PubMed logo are registered trademarks of the U.S. Department of Health and Human Services (HHS). Unauthorized use of these marks is strictly prohibited.


[8]ページ先頭

©2009-2025 Movatter.jp