Movatterモバイル変換


[0]ホーム

URL:


Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
Thehttps:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

NIH NLM Logo
Log inShow account info
Access keysNCBI HomepageMyNCBI HomepageMain ContentMain Navigation
pubmed logo
Advanced Clipboard
User Guide

Full text links

Springer full text link Springer
Full text links

Actions

Share

.2007 Apr;387(8):2737-43.
doi: 10.1007/s00216-007-1123-4. Epub 2007 Feb 17.

New FRET primers for quantitative real-time PCR

Affiliations

New FRET primers for quantitative real-time PCR

Ashraf I Ahmad et al. Anal Bioanal Chem.2007 Apr.

Abstract

FRET primer real-time PCR chemistry depends on internally labeled primers with FRET dyes linked to their 3' end. The best distance between the FRET dyes for obtaining the largest signal and the lowest background is six nucleotides. In this study the forward primer was labeled with FAM and the reverse primer with Texas red; the labeled primers meet in cycle two of PCR. At the end of the elongation step FAM is excited to emit fluorescence which will excite Texas red to emit new fluorescence that correlates directly with the quantity of PCR product accumulated. FRET primer techniques amplify short amplicons with unique thermal cycling steps, 0 s at 85 degrees C for denaturation, 7 s for annealing, and 2 s for elongation. The FRET primer technique was very efficient (92.6, 97.2, and 100%), correlation coefficients were high (1.0, 0.999, and 0.999), and total run time was very short (20, 45, and 40 min per 40 cycles with LightCycler, iCycler, and RotorGene 3000, respectively). When FRET-labeled primers were compared with similar but unlabeled primers it was observed that the FRET primer technique had a lower Ct value and was more efficient than use of unlabeled primers detected by use of SYBR Green I.

PubMed Disclaimer

Similar articles

See all similar articles

Cited by

MeSH terms

Substances

LinkOut - more resources

Full text links
Springer full text link Springer
Cite
Send To

NCBI Literature Resources

MeSHPMCBookshelfDisclaimer

The PubMed wordmark and PubMed logo are registered trademarks of the U.S. Department of Health and Human Services (HHS). Unauthorized use of these marks is strictly prohibited.


[8]ページ先頭

©2009-2025 Movatter.jp