Movatterモバイル変換


[0]ホーム

URL:


Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
Thehttps:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

NIH NLM Logo
Log inShow account info
Access keysNCBI HomepageMyNCBI HomepageMain ContentMain Navigation
pubmed logo
Advanced Clipboard
User Guide

Full text links

Wiley full text link Wiley
Full text links

Actions

.2005 Jul;54(1):241-5.
doi: 10.1002/mrm.20541.

Evolution of the longitudinal magnetization for pulse sequences using a fast spin-echo readout: application to fluid-attenuated inversion-recovery and double inversion-recovery sequences

Affiliations

Evolution of the longitudinal magnetization for pulse sequences using a fast spin-echo readout: application to fluid-attenuated inversion-recovery and double inversion-recovery sequences

Simon J P Meara et al. Magn Reson Med.2005 Jul.

Erratum in

  • Magn Reson Med. 2005 Aug;54(2):506

Abstract

The fast spin-echo (FSE) sequence is frequently used as a fast data-readout technique in conjunction with other pulse sequence elements, such as in fluid-attenuated inversion-recovery (FLAIR) and double inversion-recovery (DIR) sequences. In order to implement those pulse sequences, an understanding is required of how the longitudinal magnetization evolves during the FSE part of the sequence. This evolution has been addressed to a certain extent by previous publications, but the DIR literature in particular appears to be replete with approximations to the exact expression for the longitudinal magnetization, and several papers contain errors. Equations are therefore presented here for the evolution of the longitudinal magnetization for a FSE readout. These are then applied to calculate the magnetization available immediately prior to the 90 degrees imaging pulse for the FLAIR-FSE and DIR-FSE pulse sequences.

PubMed Disclaimer

Publication types

MeSH terms

Substances

LinkOut - more resources

Full text links
Wiley full text link Wiley
Cite
Send To

NCBI Literature Resources

MeSHPMCBookshelfDisclaimer

The PubMed wordmark and PubMed logo are registered trademarks of the U.S. Department of Health and Human Services (HHS). Unauthorized use of these marks is strictly prohibited.


[8]ページ先頭

©2009-2026 Movatter.jp