Movatterモバイル変換


[0]ホーム

URL:


Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
Thehttps:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

NIH NLM Logo
Log inShow account info
Access keysNCBI HomepageMyNCBI HomepageMain ContentMain Navigation
pubmed logo
Advanced Clipboard
User Guide

Full text links

Wiley full text link Wiley
Full text links

Actions

Share

.2004 May 1;69(2):205-15.
doi: 10.1002/jbm.a.10163.

Quantitative analysis of three-dimensional fluid flow in rotating bioreactors for tissue engineering

Affiliations

Quantitative analysis of three-dimensional fluid flow in rotating bioreactors for tissue engineering

Edward A Botchwey et al. J Biomed Mater Res A..

Abstract

Tissue engineering has emerged as a viable alternative to the problem of organ and tissue shortage. Our laboratory has developed matrices for bone tissue engineering based on sintered spherical particles and, using bioreactor technology, has demonstrated the ability to produce highly mineralized matrices in vitro. In this study, porous microcapsule scaffolds were developed for bone tissue engineering in the high aspect ratio vessel rotating bioreactor. The motion of individual microcapsules as well as scaffolds in the bioreactor were studied by numerical simulation and in situ imaging analysis. Results show that spherical microcapsules with density less than the surrounding fluid exhibited two motions: (1) a periodic circular orbit with tangential speed equal to the free fall speed of the particle, and (2) an inward radial migration of the circular orbit toward the center of the bioreactor vessel. Lighter-than-water scaffolds were fabricated by sintering poly(lactic-co-glycolic acid) hollow microcarriers with diameter from 500 to 860 microm into a fixed three-dimensional geometry with approximately 30% pore volume and 180 to 190 microm median pore size. Scaffolds were fabricated with aggregate densities ranging from 0.65 g/mL and 0.99 g/mL by appropriate combinations of hollow and solid microcarriers within the scaffold. Scaffold velocity in the bioreactor for the above range of densities was accurately predicted by numerical simulation and ranged from 100 mm/s to 3 mm/s. Maximum shear stress estimation due to media flow over the exterior of the scaffold ranged from 0.3 N/m(2) to 0.006 N/m(2). Internal perfusion velocity through scaffolds also was calculated and ranged from 13 mm/s to 0.2 mm/s. Estimates of maximum interior shear stress ranged from 0.03 to 0.0007 N/m(2). These analytical methods provide an excellent vehicle for the study of bone tissue synthesis in three-dimensional culture with fluid flow.

Copyright 2004 Wiley Periodicals, Inc. J Biomed Mater Res 69A: 205-215, 2004

PubMed Disclaimer

Similar articles

See all similar articles

Cited by

See all "Cited by" articles

Publication types

MeSH terms

Substances

Grants and funding

LinkOut - more resources

Full text links
Wiley full text link Wiley
Cite
Send To

NCBI Literature Resources

MeSHPMCBookshelfDisclaimer

The PubMed wordmark and PubMed logo are registered trademarks of the U.S. Department of Health and Human Services (HHS). Unauthorized use of these marks is strictly prohibited.


[8]ページ先頭

©2009-2025 Movatter.jp