Movatterモバイル変換


[0]ホーム

URL:


Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
Thehttps:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

NIH NLM Logo
Log inShow account info
Access keysNCBI HomepageMyNCBI HomepageMain ContentMain Navigation
pubmed logo
Advanced Clipboard
User Guide

Full text links

Elsevier Science full text link Elsevier Science
Full text links

Actions

Share

Clinical Trial
.2000 Jul;290(3):279-83.
doi: 10.1016/S1438-4221(00)80126-5.

Early diagnosis of bubonic plague using F1 antigen capture ELISA assay and rapid immunogold dipstick

Affiliations
Clinical Trial

Early diagnosis of bubonic plague using F1 antigen capture ELISA assay and rapid immunogold dipstick

S Chanteau et al. Int J Med Microbiol.2000 Jul.

Abstract

Plague is still prevalent in more than 20 countries. Two F1 antigen diagnostic assays (an immunocapture ELISA and an immunogold chromatography dipstick) were evaluated using bubo aspirates, serum and urine specimens from patients suspected with plague. The specificity of the two F1 assays was found 100%. Using bacteriology as a gold reference diagnostic assay, 52 patients were Yersinia pestis culture positive and 141 negative. The sensitivity of the F1 ELISA test was 100% in bubo, 52% in serum and 58% in urine specimens. In culture negative patients, the F1 antigen could be found in 10% bubo aspirates, 5% serum and 7% urine specimens of culture negative patients for whom a seroconversion for anti-F1 antibodies was also observed. The sensitivity of the dipstick assay was 98% on bubo aspirates specimens. Compared to the ELISA test, the agreement rate was 97.5% and the correlation coefficient tau = 0.90 (p < 10(-3)). In conclusion, the diagnosis of bubonic plague has to be performed on bubo fluid rather than on serum or urine specimens. Both the F1 ELISA and the dipstick assays are valuable tools for an early diagnosis and for the surveillance of plague.

PubMed Disclaimer

Similar articles

See all similar articles

Cited by

See all "Cited by" articles

Publication types

MeSH terms

Substances

Related information

LinkOut - more resources

Full text links
Elsevier Science full text link Elsevier Science
Cite
Send To

NCBI Literature Resources

MeSHPMCBookshelfDisclaimer

The PubMed wordmark and PubMed logo are registered trademarks of the U.S. Department of Health and Human Services (HHS). Unauthorized use of these marks is strictly prohibited.


[8]ページ先頭

©2009-2025 Movatter.jp