Movatterモバイル変換


[0]ホーム

URL:


Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
Thehttps:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

NIH NLM Logo
Log inShow account info
Access keysNCBI HomepageMyNCBI HomepageMain ContentMain Navigation
pubmed logo
Advanced Clipboard
User Guide

Full text links

Atypon full text link Atypon
Full text links

Actions

.1999;16(3):197-206.
doi: 10.1080/08990229970456.

Grating orientation as a measure of tactile spatial acuity

Affiliations

Grating orientation as a measure of tactile spatial acuity

J C Craig. Somatosens Mot Res.1999.

Abstract

Recent studies have used grating orientation as a measure of tactile spatial acuity on the fingerpad. In this task subjects identify the orientation of a grooved surface presented in either the proximal-distal or lateral-medial orientation. Other recent results have suggested that there might be a substantial anisotropy on the fingerpad related to spatial sensitivity. This anisotropy was revealed using a task in which subjects discriminated between a smooth and a grooved surface presented at different orientations on the fingerpad. The anisotropy was substantial enough that it might permit subjects to discriminate grating orientation on the basis of intensive rather than spatial cues. The present study examined the possibility that anisotropy on the fingerpad might provide cues in a spatial acuity task. The ability of subjects to discriminate between a smooth and a grooved surface was measured under conditions that are typically used in grating orientation tasks. No evidence of anisotropy was found. Also, using a grating orientation task, separate estimates were made of sensitivity in the proximal-distal and lateral-medial orientations. Again no evidence of anisotropy was found. Consistent with changes in the density of innervation, grating orientation sensitivity was found to vary as a function of location on the fingerpad. The results support the view that grating orientation is a valid measure of spatial acuity reflecting underlying neural, spatial mechanisms.

PubMed Disclaimer

Publication types

MeSH terms

Grants and funding

LinkOut - more resources

Full text links
Atypon full text link Atypon
Cite
Send To

NCBI Literature Resources

MeSHPMCBookshelfDisclaimer

The PubMed wordmark and PubMed logo are registered trademarks of the U.S. Department of Health and Human Services (HHS). Unauthorized use of these marks is strictly prohibited.


[8]ページ先頭

©2009-2026 Movatter.jp