Wu et al., 2023 - Google Patents

APP: Enabling soft real-time execution on densely-populated hybrid memory system

Wu et al., 2023

Document ID
6394322020368534385
Author
Wu Z
Chen Y
Chang Y
Kuo T
Publication year
Publication venue
2023 60th ACM/IEEE Design Automation Conference (DAC)

External Links

Snippet

Memory swapping was considered slow and evil, but swapping to Ultra Low-Latency storage like Optane has become a promising solution to save power and cost, helping densely-populated edge server to overcome its DRAM capacity bottleneck. However, the …
Continue reading atieeexplore.ieee.org (other versions)

Classifications

The classifications are assigned by a computer and are not a legal conclusion. Google has not performed a legal analysis and makes no representation as to the accuracy of the classifications listed.
    • GPHYSICS
    • G06COMPUTING; CALCULATING; COUNTING
    • G06FELECTRICAL DIGITAL DATA PROCESSING
    • G06F9/00Arrangements for programme control, e.g. control unit
    • G06F9/06Arrangements for programme control, e.g. control unit using stored programme, i.e. using internal store of processing equipment to receive and retain programme
    • G06F9/46Multiprogramming arrangements
    • G06F9/50Allocation of resources, e.g. of the central processing unit [CPU]
    • G06F9/5005Allocation of resources, e.g. of the central processing unit [CPU] to service a request
    • G06F9/5011Allocation of resources, e.g. of the central processing unit [CPU] to service a request the resources being hardware resources other than CPUs, Servers and Terminals
    • GPHYSICS
    • G06COMPUTING; CALCULATING; COUNTING
    • G06FELECTRICAL DIGITAL DATA PROCESSING
    • G06F9/00Arrangements for programme control, e.g. control unit
    • G06F9/06Arrangements for programme control, e.g. control unit using stored programme, i.e. using internal store of processing equipment to receive and retain programme
    • G06F9/46Multiprogramming arrangements
    • G06F9/48Programme initiating; Programme switching, e.g. by interrupt
    • G06F9/4806Task transfer initiation or dispatching
    • G06F9/4843Task transfer initiation or dispatching by program, e.g. task dispatcher, supervisor, operating system
    • G06F9/4881Scheduling strategies for dispatcher, e.g. round robin, multi-level priority queues
    • GPHYSICS
    • G06COMPUTING; CALCULATING; COUNTING
    • G06FELECTRICAL DIGITAL DATA PROCESSING
    • G06F12/00Accessing, addressing or allocating within memory systems or architectures
    • G06F12/02Addressing or allocation; Relocation
    • G06F12/08Addressing or allocation; Relocation in hierarchically structured memory systems, e.g. virtual memory systems
    • G06F12/12Replacement control
    • G06F12/121Replacement control using replacement algorithms
    • GPHYSICS
    • G06COMPUTING; CALCULATING; COUNTING
    • G06FELECTRICAL DIGITAL DATA PROCESSING
    • G06F9/00Arrangements for programme control, e.g. control unit
    • G06F9/06Arrangements for programme control, e.g. control unit using stored programme, i.e. using internal store of processing equipment to receive and retain programme
    • G06F9/46Multiprogramming arrangements
    • G06F9/50Allocation of resources, e.g. of the central processing unit [CPU]
    • G06F9/5061Partitioning or combining of resources
    • G06F9/5077Logical partitioning of resources; Management or configuration of virtualized resources
    • GPHYSICS
    • G06COMPUTING; CALCULATING; COUNTING
    • G06FELECTRICAL DIGITAL DATA PROCESSING
    • G06F12/00Accessing, addressing or allocating within memory systems or architectures
    • G06F12/02Addressing or allocation; Relocation
    • G06F12/0223User address space allocation, e.g. contiguous or non contiguous base addressing
    • G06F12/023Free address space management
    • GPHYSICS
    • G06COMPUTING; CALCULATING; COUNTING
    • G06FELECTRICAL DIGITAL DATA PROCESSING
    • G06F12/00Accessing, addressing or allocating within memory systems or architectures
    • G06F12/02Addressing or allocation; Relocation
    • G06F12/08Addressing or allocation; Relocation in hierarchically structured memory systems, e.g. virtual memory systems
    • G06F12/0802Addressing of a memory level in which the access to the desired data or data block requires associative addressing means, e.g. caches
    • GPHYSICS
    • G06COMPUTING; CALCULATING; COUNTING
    • G06FELECTRICAL DIGITAL DATA PROCESSING
    • G06F1/00Details of data-processing equipment not covered by groups G06F3/00 - G06F13/00, e.g. cooling, packaging or power supply specially adapted for computer application
    • G06F1/26Power supply means, e.g. regulation thereof
    • G06F1/32Means for saving power
    • G06F1/3203Power Management, i.e. event-based initiation of power-saving mode
    • G06F1/3234Action, measure or step performed to reduce power consumption
    • GPHYSICS
    • G06COMPUTING; CALCULATING; COUNTING
    • G06FELECTRICAL DIGITAL DATA PROCESSING
    • G06F11/00Error detection; Error correction; Monitoring
    • G06F11/30Monitoring
    • G06F11/34Recording or statistical evaluation of computer activity, e.g. of down time, of input/output operation; Recording or statistical evaluation of user activity, e.g. usability assessment
    • G06F11/3409Recording or statistical evaluation of computer activity, e.g. of down time, of input/output operation; Recording or statistical evaluation of user activity, e.g. usability assessment for performance assessment
    • GPHYSICS
    • G06COMPUTING; CALCULATING; COUNTING
    • G06FELECTRICAL DIGITAL DATA PROCESSING
    • G06F2201/00Indexing scheme relating to error detection, to error correction, and to monitoring
    • G06F2201/885Monitoring specific for caches
    • GPHYSICS
    • G06COMPUTING; CALCULATING; COUNTING
    • G06FELECTRICAL DIGITAL DATA PROCESSING
    • G06F11/00Error detection; Error correction; Monitoring
    • G06F11/30Monitoring
    • G06F11/34Recording or statistical evaluation of computer activity, e.g. of down time, of input/output operation; Recording or statistical evaluation of user activity, e.g. usability assessment
    • G06F11/3466Performance evaluation by tracing or monitoring
    • GPHYSICS
    • G06COMPUTING; CALCULATING; COUNTING
    • G06FELECTRICAL DIGITAL DATA PROCESSING
    • G06F1/00Details of data-processing equipment not covered by groups G06F3/00 - G06F13/00, e.g. cooling, packaging or power supply specially adapted for computer application
    • G06F1/26Power supply means, e.g. regulation thereof
    • G06F1/32Means for saving power
    • G06F1/3203Power Management, i.e. event-based initiation of power-saving mode
    • G06F1/3206Monitoring a parameter, a device or an event triggering a change in power modality
    • GPHYSICS
    • G06COMPUTING; CALCULATING; COUNTING
    • G06FELECTRICAL DIGITAL DATA PROCESSING
    • G06F2212/00Indexing scheme relating to accessing, addressing or allocation within memory systems or architectures
    • G06F2212/10Providing a specific technical effect
    • G06F2212/1032Reliability improvement, data loss prevention, degraded operation etc
    • G06F2212/1036Life time enhancement

Similar Documents

PublicationPublication DateTitle
US8799554B1 (en)Methods and system for swapping memory in a virtual machine environment
US8032723B2 (en)Methods and mechanisms for proactive memory management
US8458709B2 (en)Dynamic switching of multithreaded processor between single threaded and simultaneous multithreaded modes
CN113778662B (en)Memory recovery method and device
Qiao et al.Hermit:{Low-Latency},{High-Throughput}, and Transparent Remote Memory via {Feedback-Directed} Asynchrony
Li et al.SEAL: User experience-aware two-level swap for mobile devices
US8930732B2 (en)Fast speed computer system power-on and power-off method
US10185384B2 (en)Reducing power by vacating subsets of CPUs and memory
TWI399637B (en) Fast switch machine method
Li et al.Improving preemptive scheduling with application-transparent checkpointing in shared clusters
Maruf et al.Memtrade: Marketplace for disaggregated memory clouds
Maruf et al.Memtrade: A disaggregated-memory marketplace for public clouds
US20160170474A1 (en)Power-saving control system, control device, control method, and control program for server equipped with non-volatile memory
US10678705B2 (en)External paging and swapping for dynamic modules
Zhong et al.Building NVRAM-aware swapping through code migration in mobile devices
Wu et al.APP: Enabling soft real-time execution on densely-populated hybrid memory system
US6016531A (en)Apparatus for performing real time caching utilizing an execution quantization timer and an interrupt controller
Niu et al.Pfha: A novel page migration algorithm for hybrid memory embedded systems
Ji et al.Fair down to the device: A GC-aware fair scheduler for SSD
Jeong et al.DaaC: device-reserved memory as an eviction-based file cache
KR100656353B1 (en) How to reduce memory power consumption
Lee et al.Alleviating I/O Interference in Virtualized Systems With VM-Aware Persistency Control
Park et al.A4: Microarchitecture-Aware LLC Management for Datacenter Servers with Emerging I/O Devices
Liu et al.OKAM: A Linux Application Manager Based on Hierarchical Freezing Technology
Wei et al.App-aware Swap Resource Allocation for Enhancing User-perceived Latency on Mobile Devices

[8]
ページ先頭

©2009-2025 Movatter.jp