A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets

Jaffray et al., 1999

Document ID
18055025217378541356
Author
Jaffray D
Drake D
Moreau M
Martinez A
Wong J
Publication year
Publication venue
International Journal of Radiation Oncology* Biology* Physics

External Links

Snippet

Purpose: Dose escalation in conformal radiation therapy requires accurate field placement. Electronic portal imaging devices are used to verify field placement but are limited by the low subject contrast of bony anatomy at megavoltage (MV) energies, the large imaging dose …
Continue reading atwww.sciencedirect.com (other versions)

Classifications

The classifications are assigned by a computer and are not a legal conclusion. Google has not performed a legal analysis and makes no representation as to the accuracy of the classifications listed.
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B6/00Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
    • A61B6/02Devices for diagnosis sequentially in different planes; Stereoscopic radiation diagnosis
    • A61B6/03Computerised tomographs
    • A61B6/032Transmission computed tomography [CT]
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B6/00Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
    • A61B6/42Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment with arrangements for detecting radiation specially adapted for radiation diagnosis
    • A61B6/4291Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment with arrangements for detecting radiation specially adapted for radiation diagnosis the detector being combined with a grid or grating
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B6/00Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
    • A61B6/58Testing, adjusting or calibrating devices for radiation diagnosis
    • A61B6/582Calibration
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B6/00Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
    • A61B6/48Diagnostic techniques
    • A61B6/482Diagnostic techniques involving multiple energy imaging
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61NELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
    • A61N5/00Radiation therapy
    • A61N5/10X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
    • A61N5/1048Monitoring, verifying, controlling systems and methods
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61NELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
    • A61N5/00Radiation therapy
    • A61N5/10X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
    • A61N5/1077Beam delivery systems
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B6/00Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
    • A61B6/44Constructional features of the device for radiation diagnosis
    • A61B6/4429Constructional features of the device for radiation diagnosis related to the mounting of source units and detector units
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B6/00Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
    • A61B6/40Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment with arrangements for generating radiation specially adapted for radiation diagnosis
    • A61B6/4064Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment with arrangements for generating radiation specially adapted for radiation diagnosis adapted for producing a particular type of beam
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B6/00Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
    • A61B6/40Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment with arrangements for generating radiation specially adapted for radiation diagnosis
    • A61B6/4007Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment with arrangements for generating radiation specially adapted for radiation diagnosis characterised by using a plurality of source units
    • A61B6/4014Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment with arrangements for generating radiation specially adapted for radiation diagnosis characterised by using a plurality of source units arranged in multiple source-detector units
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B6/00Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
    • A61B6/50Clinical applications
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B6/00Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
    • A61B6/54Control of devices for radiation diagnosis
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B6/00Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
    • A61B6/04Positioning of patients; Tiltable beds or the like

Similar Documents

PublicationPublication DateTitle
Jaffray et al.A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets
Murphy et al.The management of imaging dose during image‐guided radiotherapy: report of the AAPM Task Group 75
Groh et al.A performance comparison of flat‐panel imager‐based MV and kV cone‐beam CT
Mail et al.The influence of bowtie filtration on cone‐beam CT image quality
Jaffray et al.Flat-panel cone-beam computed tomography for image-guided radiation therapy
CN100448499C (en)Cone beam computerized tomography with flat panel imager
Siewerdsen et al.The influence of antiscatter grids on soft‐tissue detectability in cone‐beam computed tomography with flat‐panel detectors: antiscatter grids in cone‐beam CT
Karius et al.Technical evaluation of the cone‐beam computed tomography imaging performance of a novel, mobile, gantry‐based X‐ray system for brachytherapy
US20220395243A1 (en)RADIOTHERAPY APPARATUS AND METHODS FOR TREATMENT AND IMAGING USING HYBRID MeV-keV, MULTI-ENERGY DATA ACQUISITION FOR ENHANCED IMAGING
US20060153330A1 (en)System for radiation imaging and therapy of small animals
Ren et al.Feasibility study of as ynchronized‐mo ving‐g rid (SMOG) system to improve image quality in cone‐beam computed tomography (CBCT)
Li et al.Implementation of dual‐energy technique for virtual monochromatic and linearly mixed CBCTs
Karius et al.Cone‐beam CT imaging with laterally enlarged field of view based on independently movable source and detector
Ghazi et al.A novel hardware duo of beam modulation and shielding to reduce scatter acquisition and dose in cone‐beam breast CT
Bai et al.Phantom evaluation of a cardiac SPECT/VCT system that uses a common set of solid-state detectors for both emission and transmission scans
Yang et al.Scatter radiation intensities around a clinical digital breast tomosynthesis unit and the impact on radiation shielding considerations
Hamada et al.Examination of a dose evaluation method for floor-mounted kV X-ray image-guided radiation therapy systems
Falco et al.Preliminary studies for a CBCT imaging protocol for offline organ motion analysis: registration software validation and CTDI measurements
Lindsay et al.Investigation of combined kV/MV CBCT imaging with a high‐DQE MV detector
Speidel et al.Feasibility of low‐dose single‐view 3D fiducial tracking concurrent with external beam delivery
Yoshizumi et al.Radiation issues with multidetector row helical CT
Nelson et al.Patient dose simulations for scanning‐beam digital x‐ray tomosynthesis of the lungs
Zhang et al.Minimizing image noise in on‐board CT reconstruction using both kilovoltage and megavoltage beam projections
Paraiso LaboraCalibration of a C-arm X-ray system for its use in tomography
JarryStudy of novel techniques for verification imaging and patient dose reconstruction in external beam radiation therapy

[8]
ページ先頭

©2009-2025 Movatter.jp