Movatterモバイル変換


[0]ホーム

URL:


Skip to content

Navigation Menu

Sign in
Appearance settings

Search code, repositories, users, issues, pull requests...

Provide feedback

We read every piece of feedback, and take your input very seriously.

Saved searches

Use saved searches to filter your results more quickly

Sign up
Appearance settings

Custom formatter can log on .NET 8 but not on .NET 6 when TraceId is used due to a conflict with System.Diagnostics.DiagnosticSource #160

Open
@cmhernandezdel

Description

@cmhernandezdel

Using Serilog 3.1.1 but happens to me too with 4.0.0.

When I try to enter into this function in my own formatter:

privatevoidWriteTraceId(LogEventlogEvent,TextWriteroutput){if(!logEvent.TraceId.HasValue||!_settings.LogTraceId){return;}output.Write(',');output.Write('"');output.Write(_settings.TraceIdName);output.Write('"');output.Write(':');_jsonValueFormatter.WriteQuotedJsonString(logEvent.TraceId.Value.ToHexString(),output);}

I get the following exception:

System.IO.FileNotFoundException: Could not load file or assembly 'System.Diagnostics.DiagnosticSource, Version=7.0.0.0, Culture=neutral, PublicKeyToken=cc7b13ffcd2ddd51'. El sistema no puede encontrar el archivo especificado.File name: 'System.Diagnostics.DiagnosticSource, Version=7.0.0.0, Culture=neutral, PublicKeyToken=cc7b13ffcd2ddd51'   at Link.VisiotechSerilog.Formatters.SerilogJsonFormatter.WriteTraceId(LogEvent logEvent, TextWriter output)   at Link.VisiotechSerilog.Formatters.SerilogJsonFormatter.Format(LogEvent logEvent, TextWriter output) in C:\Users\chernandez\Source\visiotechserilog-module\Link.VisiotechSerilog\Link.VisiotechSerilog\Formatters\SerilogJsonFormatter.cs:line 34   at Serilog.Sinks.SystemConsole.ConsoleSink.Emit(LogEvent logEvent)   at Serilog.Core.Sinks.SafeAggregateSink.Emit(LogEvent logEvent)

I think the package pulls version 7.0.2 and it's trying to use 7.0.0, this is anetstandard2.1 library which uses Serilog, when we use the library in .NET 8, it works well, but when used in .NET 6 we get this exception.

If I omitTraceId orSpanId logging, it works well, but whenever any of those two properties are involved, I get the exception.

However, the properties are set, as you can see from the debugger:

imagen

If you need more info let me know and I'll try to help!

Metadata

Metadata

Assignees

No one assigned

    Labels

    No labels
    No labels

    Type

    No type

    Projects

    No projects

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions


      [8]ページ先頭

      ©2009-2025 Movatter.jp