doc: Mention clock synchronization recommendation for hot_standby_feedback
hot_standby_feedback mechanics assume that clocks are synchronized,but it was not clear from documentation.Author: Jakub Wartak <jakub.wartak@enterprisedb.com>Reviewed-by: Euler Taveira <euler@eulerto.com>Reviewed-by: Amit Kapila <amit.kapila16@gmail.com>Reviewed-by: vignesh C <vignesh21@gmail.com>Discussion:https://postgr.es/m/CAKZiRmwBcALLrDgCyEhHP1enUxtPMjyNM_d1A2Lng3_6Rf4Qfw%40mail.gmail.com
1 parente2809e3 commit0fcf02a

File tree

1 file changed

+7
-0
lines changed

1 file changed

+7
-0
lines changed

‎doc/src/sgml/config.sgml

Lines changed: 7 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -5068,6 +5068,13 @@ ANY <replaceable class="parameter">num_sync</replaceable> ( <replaceable class="
50685068
until it eventually reaches the primary. Standbys make no other use
50695069
of feedback they receive other than to pass upstream.
50705070
</para>
5071+
<para>
5072+
Note that if the clock on standby is moved ahead or backward, the
5073+
feedback message might not be sent at the required interval. In
5074+
extreme cases, this can lead to a prolonged risk of not removing dead
5075+
rows on the primary for extended periods, as the feedback mechanism is
5076+
based on timestamps.
5077+
</para>