Segfault with hook "simple get" cache slot and minimal JIT #15834

Closed
@nielsdos

Description

@nielsdos

Description

Originally posted in#15819 (comment)

The following code:

<?phpclass A {private$_prop;public$prop {        get =>$this->_prop;    }}for ($i=0;$i<2;$i++)echo (newA)->prop;

usingopcache.jit=1101

Resulted in this output:

Segfault

But I expected this output instead:

No segfault

I analysed this and this is a different bug related to a cache slot optimization.
As far as I understand, this happens for when the cache slot satisfies theZEND_IS_PROPERTY_HOOK_SIMPLE_GET condition. Then we set up a function call frame and re-enter the VM to execute the hook function:

php-src/Zend/zend_vm_def.h

Lines 2094 to 2126 in7c2204c

}elseif (EXPECTED(ZEND_IS_PROPERTY_HOOK_SIMPLE_GET(prop_offset))) {
zend_function*hook=prop_info->hooks[ZEND_PROPERTY_HOOK_GET];
ZEND_ASSERT(hook->type==ZEND_USER_FUNCTION);
ZEND_ASSERT(RUN_TIME_CACHE(&hook->op_array));
uint32_tcall_info=ZEND_CALL_NESTED_FUNCTION |ZEND_CALL_HAS_THIS;
if (OP1_TYPE&IS_CV) {
GC_ADDREF(zobj);
}
if (OP1_TYPE& (IS_CV|IS_VAR|IS_TMP_VAR)) {
call_info |=ZEND_CALL_RELEASE_THIS;
}
zend_execute_data*call=zend_vm_stack_push_call_frame(call_info,hook,0,zobj);
call->prev_execute_data=execute_data;
call->call=NULL;
call->return_value=EX_VAR(opline->result.var);
call->run_time_cache=RUN_TIME_CACHE(&hook->op_array);
execute_data=call;
EG(current_execute_data)=execute_data;
zend_init_cvs(0,hook->op_array.last_varEXECUTE_DATA_CC);
#if defined(ZEND_VM_IP_GLOBAL_REG)&& ((ZEND_VM_KIND==ZEND_VM_KIND_CALL)|| (ZEND_VM_KIND==ZEND_VM_KIND_HYBRID))
opline=hook->op_array.opcodes;
#else
EX(opline)=hook->op_array.opcodes;
#endif
LOAD_OPLINE_EX();
ZEND_OBSERVER_SAVE_OPLINE();
ZEND_OBSERVER_FCALL_BEGIN(execute_data);
ZEND_VM_ENTER_EX();
}

This seems incompatible with how the minimal JIT works, getting the property will be skipped.
Indeed if we get rid ofZEND_SET_PROPERTY_HOOK_SIMPLE_GET inzend_object_handlers.c or go to a higher optimization level the problem disappears. I'm not sure yet how to solve that.