Exporters shutdown takes longer then a minute when failing to send metrics/traces #3309

Labels
bugSomething isn't working
@Elli-Rid

Description

@Elli-Rid

Environment: Mac OS, RHEL 8 (doesn't matter)

Configure traces and/or metrics GRPC exporter with invalid collector URL

  # init tracing  trace_provider = TracerProvider(resource=resource)  trace_exporter = create_trace_exporter(exporter, otlp_config, jaeger_config)  trace_processor = BatchSpanProcessor(trace_exporter)  trace_provider.add_span_processor(trace_processor)  telemetry_trace.set_tracer_provider(trace_provider)  # init metrics  global _telemetry_meter  # pylint: disable=global-statement  metrics_exporter = create_metrics_exporter(exporter, otlp_config)  metric_reader = PeriodicExportingMetricReader(      metrics_exporter, export_interval_millis=export_interval, export_timeout_millis=3000  )  metrics_provider = MeterProvider(resource=resource, metric_readers=[metric_reader])  telemetry_metrics.set_meter_provider(metrics_provider)  _telemetry_meter = telemetry_metrics.get_meter_provider().get_meter(service_name, str(service_version))

What is the expected behavior?
When executing:

meter_provider = telemetry_metrics.get_meter_provider()if meter_provider and (shutdown_meter := getattr(meter_provider, 'shutdown', None)):    shutdown_meter(timeout_millis=3000)

it should shutdown in about 3 seconds

What is the actual behavior?
It takes ~60 seconds to shutdown with logs like

WARNING - opentelemetry.exporter.otlp.proto.grpc.exporter::_export:363 | Transient error StatusCode.UNAVAILABLE encountered while exporting metrics, retrying in 8s.

Additional context
From what it looks like both metrics and traces exporters usethis base/mixin which has atimeout_millis

Now going level up whereOTLPMetricExporter.shudown calls it correctly

    def shutdown(self, timeout_millis: float = 30_000, **kwargs) -> None:        OTLPExporterMixin.shutdown(self, timeout_millis=timeout_millis)

However,PeriodicExportingMetricReader.shutdown callsOTLPMetricExporter.shutdown with a different kwarg name which seems to be completely ignored

    def shutdown(self, timeout_millis: float = 30_000, **kwargs) -> None:        deadline_ns = time_ns() + timeout_millis * 10**6        def _shutdown():            self._shutdown = True        did_set = self._shutdown_once.do_once(_shutdown)        if not did_set:            _logger.warning("Can't shutdown multiple times")            return        self._shutdown_event.set()        if self._daemon_thread:            self._daemon_thread.join(                timeout=(deadline_ns - time_ns()) / 10**9            )        self._exporter.shutdown(timeout=(deadline_ns - time_ns()) / 10**6)  # <--- timeout vs timeout_millis
  • given the use oftime_ns() if correct kwarg name it would lead to the error of negative timeout value being supplied

As for traces,exporter calls OTLPExporterMixin.shutdown without propagating any timeouts at all.

This leads to some bad behaviour when combined with k8s and async application since timeoutless thread lock blocks event loop and also leads to hanging containers in k8s cluster until they are killed.