Zigbee: Multiple endpoints crash due to static endpoint var #10726

Closed
Assignees
P-R-O-C-H-Y
Labels
Area: ZigbeeIssues and Feature Request about ZigbeeStatus: SolvedThe issue has been resolved and requires no further action.
@FaBjE

Description

@FaBjE

When adding a second Zigbee endpoint the CPU crashes.
I noticed that the same endpoint ID was displayed while I added both endpoints with separate ID's

After some digging I found that the ZigbeeEP class has the endpoint variable as static.
This is not possible as each instance (aka endpoint) must have a unique endpoint ID.
I removed the static and it started working:FaBjE@f0566d8

Unfortunately this breaks several classes as they rely on the endpoint and others being static. For testing I removed those classes so I could compile:FaBjE@2c98584

I think there is some awareness about this issue, but maybe not the severity when trying to use a second endpoint.
Originally posted by@P-R-O-C-H-Y in#10135 (comment)

Metadata

Metadata

Assignees

Labels

Area: ZigbeeIssues and Feature Request about ZigbeeStatus: SolvedThe issue has been resolved and requires no further action.

Type

No type

Projects

No projects

Milestone

No milestone

Relationships

None yet

Development

No branches or pull requests

Issue actions


    [8]ページ先頭

    ©2009-2025 Movatter.jp