Assembly of electrodes at either end of an insulated tube filled with gas
This article is about tubes producing visible discharges or used for switching purposes. For the use of gas-filled tubes for radiation detection, seeGaseous ionization detector.
The voltage required to initiate and sustain discharge is dependent on thepressure and composition of the fill gas and geometry of the tube. Although the envelope is typically glass, power tubes often useceramics, and military tubes often use glass-lined metal. Bothhot cathode andcold cathode type devices are encountered.
Hydrogen is used in tubes used for very fast switching, e.g. somethyratrons,dekatrons, andkrytrons, where very steep edges are required. The build-up and recovery times of hydrogen are much shorter than in other gases.[1] Hydrogen thyratrons are usually hot-cathode. Hydrogen (and deuterium) can be stored in the tube in the form of a metalhydride, heated with an auxiliary filament; hydrogen by heating such storage element can be used to replenish cleaned-up gas, and even to adjust the pressure as needed for a thyratron operation at a given voltage.[2]
Deuterium is used inultraviolet lamps forultraviolet spectroscopy, inneutron generator tubes, and in special tubes (e.g.crossatron). It has higher breakdown voltage than hydrogen. In fast switching tubes it is used instead of hydrogen where high voltage operation is required.[3] For a comparison, the hydrogen-filled CX1140 thyratron has anode voltage rating of 25 kV, while the deuterium-filled and otherwise identical CX1159 has 33 kV. Also, at the same voltage the pressure of deuterium can be higher than of hydrogen, allowing higher rise rates of current before it causes excessive anode dissipation. Significantly higher peak powers are achievable. Its recovery time is, however, about 40% slower than for hydrogen.[2]
Noble gases are frequently used in tubes for many purposes, from lighting to switching. Pure noble gases are employed in switching tubes. Noble-gas-filled thyratrons have better electrical parameters than mercury-based ones.[3] The electrodes undergo damage by high-velocity ions. The neutral atoms of the gas slow the ions down by collisions, and reduce the energy transferred to the electrodes by the ion impact. Gases with high atomic weight, e.g. xenon, protect the electrodes better than lighter ones, e.g. neon.[4]
Helium is used inhelium–neon lasers and in some thyratrons rated for high currents and high voltages. Helium provides about as short deionization time as hydrogen, but can withstand lower voltage, so it is used much less often.[5]
Neon has low ignition voltage and is frequently used in low-voltage tubes. Discharge in neon emits relatively bright red light; neon-filled switching tubes therefore also act as indicators, shining red when switched on. This is exploited in thedecatron tubes, which act as both counters and displays. Its red light is exploited inneon signage. Used influorescent tubes with high power and short length, e.g. industrial lighting tubes. Has higher voltage drop in comparison with argon and krypton. Its low atomic mass provides only a little protection to the electrodes against accelerated ions; additional screening wires or plates can be used for prolonging the anode lifetime. In fluorescent tubes it is used in combination with mercury.[4]
Argon was the first gas used in fluorescent tubes and is still frequently used due to its low cost, high efficiency, and very low striking voltage. In fluorescent tubes it is used in combination with mercury.[4] It was also used in earlyrectifier tubes; first thyratrons were derived from such argon-filled tubes.
Krypton can be used in fluorescent lamps instead of argon; in that application it reduces the total energy losses on electrodes from about 15% to 7%. The voltage drop per lamp length is however lower than with argon, which can be compensated by smaller tube diameter. Krypton-filled lamps also require higher starting voltage; this can be alleviated by using e.g. 25–75% argon-krypton mixture. In fluorescent tubes it is used in combination with mercury.[4]
Xenon in pure state has high breakdown voltage, making it useful in higher-voltage switching tubes. Xenon is also used as a component of gas mixtures when production of ultraviolet radiation is required, e.g. inplasma displays, usually to excite aphosphor. The wavelength produced is longer than with argon and krypton and penetrates the phosphors better. To lower the ionization voltage, neon-xenon or helium-xenon are used; above 350 Torr (47 kPa), helium has lower breakdown voltage than neon and vice versa. At concentrations of 1% and less of xenon, thePenning effect becomes significant in such mixtures, as most of xenon ionization occurs by collision with excited atoms of the other noble gas; at more than few percents of xenon, the discharge ionizes xenon directly due to most energy of the electrons being spent on direct ionization of xenon.[6]
Mercury vapors are used for applications with high current, e.g. lights,mercury-arc valves,ignitrons. Mercury is used because of its high vapor pressure and low ionization potential. Mercury mixed with an inert gas is used where the energy losses in the tube have to be low and the tube lifetime should be long. In mercury-inert gas mixtures, the discharge is initially carried primarily by the inert gas; the released heat then serves to evaporate enough mercury to reach the desired vapor pressure. Low-voltage (hundreds volts) rectifiers use saturated mercury vapor in combination with a small amount of inert gas, allowing cold start of the tubes. High-voltage (kilovolts and more) rectifiers use pure mercury vapor at low pressure, requiring maintenance of maximum temperature of the tube. The liquid mercury serves as a reservoir of mercury, replenishing the vapors that are used up during the discharge. Unsaturated mercury vapor can be used, but as it can not be replenished, the lifetime of such tubes is lower.[1] The strong dependence of vapor pressure on mercury temperature limits the environments the mercury-based tubes can operate in. In low-pressure mercury lamps, there is an optimum mercury pressure for the highest efficiency. Photons emitted by ionized mercury atoms can be absorbed by nearby nonionized atoms and either reradiated or the atom is deexcited nonradiatively, too high mercury pressure therefore causes losses of light. Too low mercury pressure leads to too few atoms present to get ionized and radiate photons. The optimum temperature for low-pressure mercury lamps is at about 42 °C (108 °F), when the saturated vapor pressure of mercury (present as a drop of about 1 mg of liquid mercury in the tube, as a reservoir compensating for losses by clean-up) reaches this optimum. In lamps intended for operation at higher ambient temperatures, and at a wider temperature range, mercury is present in the form of anamalgam with e.g.bismuth andindium; the vapor pressure above amalgam is lower than above liquid mercury.[7] Mercury is used influorescent tubes as a source of visible and ultraviolet light for exciting thephosphor; in that application it is usually used together with argon, or in some cases with krypton or neon. Mercury ions deionize slowly, limiting the switching speed of mercury-filled thyratrons. Ion bombardment with mercury ions of even relatively low energies also gradually destroys oxide-coated cathodes.[2]
Air can be used in some low-demanding applications.
Nitrogen at relatively high pressure tends to be used insurge arresters, due to its short build-up time, giving the tubes fast response time to voltage surges.[1]
Halogens andalcohol vapors absorb ultraviolet radiation and have high electron affinity. When added to inert gases, they quench the discharge; this is exploited in e.g.Geiger–Müller tubes.[1]
In special cases (e.g., high-voltage switches), gases with good dielectric properties and very high breakdown voltages are needed. Highlyelectronegative elements, e.g.,halogens, are favored as they rapidly recombine with the ions present in the discharge channel. One of the most popular choices issulfur hexafluoride, used in special high-voltage applications. Other common options are dry pressurizednitrogen andhalocarbons.
Voltage-current characteristics of electrical discharge in neon at 1 Torr (130 Pa), with two planar electrodes separated by 50 cm. A: random pulses bycosmic radiation B: saturation current C: avalancheTownsend discharge D: self-sustained Townsend discharge E: unstable region:corona discharge F: sub-normalglow discharge G: normal glow discharge H: abnormal glow discharge I: unstable region: glow-arc transition J:electric arc K: electric arc The A-D region is called a dark discharge; there is some ionization, but the current is below 10 microamperes and there is no significant amount of radiation produced. The D-G region exhibits anegative differential resistance The F-H region is a region of glow discharge; the plasma emits a faint glow that occupies almost all the volume of the tube; most of the light is emitted by excited neutral atoms. The I-K region is a region of arc discharge; the plasma is concentrated in a narrow channel along the center of the tube; a great amount of radiation is produced.
The fundamental mechanism is the Townsend discharge, which is the sustained multiplication of electron flow by ion impact when a critical value of electric field strength for the density of the gas is reached. As the electric field is increased various phases of discharge are encountered as shown in the accompanying plot. The gas used dramatically influences the parameters of the tube. The breakdown voltage depends on the gas composition and electrode distance; the dependencies are described byPaschen's law.
The gas pressure may range between 0.001 and 1,000 Torr (0.13–130,000 Pa); most commonly, pressures between 1–10 torr are used.[1] The gas pressure influences the following factors:[1]
Above a certain value, the higher the gas pressure, the higher the ignition voltage. High-pressure lighting tubes can require a few kilovolts impulse for ignition when cold, when the gas pressure is low. After warming up, when the volatile compound used for light emission is vaporized and the pressure increases, reignition of the discharge requires either significantly higher voltage or reducing the internal pressure by cooling down the lamp.[7] For example, many sodium vapor lamps cannot be re-lit immediately after being shut off; they must cool down before they can be lit up again.
The gas tends to be used up during the tube operation, by several phenomena collectively calledclean-up. The gas atoms or molecules areadsorbed on the surfaces of the electrodes. In high voltage tubes, the accelerated ions can penetrate into the electrode materials. New surfaces, formed by sputtering of the electrodes and deposited on e.g. the inner surfaces of the tube, also readily adsorb gases. Non-inert gases can also chemically react with the tube components. Hydrogen may diffuse through some metals.[1]
For removal of gas invacuum tubes,getters are used. For resupplying gas for gas-filled tubes,replenishers are employed. Most commonly, replenishers are used with hydrogen; a filament made from a hydrogen-absorbing metal (e.g. zirconium or titanium) is present in the tube, and by controlling its temperature the ratio of absorbed and desorbed hydrogen is adjusted, resulting in controlling of the hydrogen pressure in the tube. The metal filament acts as a hydrogen storage. This approach is used in e.g. hydrogen thyratrons or neutron tubes. Usage of saturated mercury vapor allows using a pool of liquid mercury as a large storage of material; the atoms lost by clean-up are automatically replenished by evaporation of more mercury. The pressure in the tube is however strongly dependent on the mercury temperature, which has to be controlled carefully.[1]
Large rectifiers use saturated mercury vapor with a small amount of an inert gas. The inert gas supports the discharge when the tube is cold.
The mercury arc valve current-voltage characteristics are highly dependent on the temperature of the liquid mercury. The voltage drop in forward bias decreases from about 60 volts at 0 °C to somewhat above 10 volts at 50 °C and then stays constant; the reverse bias breakdown ("arc-back") voltage drops dramatically with temperature, from 36 kV at 60 °C to 12 kV at 80 °C to even less at higher temperatures. The operating range is therefore usually between 18–65 °C.[9]
The gas in the tube has to be kept pure to maintain the desired properties; even small amount of impurities can dramatically change the tube values. The presence of non-inert gases generally increases the breakdown and burning voltages. The presence of impurities can be observed by changes in the glow color of the gas. Air leaking into the tube introduces oxygen, which is highly electronegative and inhibits the production of electron avalanches. This makes the discharge look pale, milky, or reddish. Traces of mercury vapors glow bluish, obscuring the original gas color. Magnesium vapor colors the discharge green. To preventoutgassing of the tube components during operation, abake-out is required before filling with gas and sealing. Thorough degassing is required for high-quality tubes; even as little as 10−8 torr (≈1 μPa) of oxygen is sufficient for covering the electrodes with monomolecular oxide layer in few hours. Non-inert gases can be removed by suitablegetters. For mercury-containing tubes, getters that do not formamalgams with mercury (e.g.zirconium, but notbarium) have to be used. Cathode sputtering may be used intentionally for gettering non-inert gases; some reference tubes usemolybdenum cathodes for this purpose.[1]
Pure inert gases are used where the difference between the ignition voltage and the burning voltage has to be high, e.g. in switching tubes. Tubes for indication and stabilization, where the difference has to be lower, tend to be filled withPenning mixtures; the lower difference between ignition and burning voltages allows using lower power supply voltages and smaller series resistances.[1]
Neon lamps andneon signage (most of which is not neon based these days) are also low-pressure gas-filled tubes.
Specialized historic low-pressure gas-filled tube devices include theNixie tube (used to display numerals) and theDecatron (used to count or divide pulses, with display as a secondary function).
Since the ignition voltage depends on the ion concentration which may drop to zero after a long period of inactivity, many tubes are primed for ion availability:
optically, by ambient light or by a 2-watt incandescent lamp, or by a glow discharge in the same envelope,
radioactively, by addingtritium to the gas, or by coating the envelope inside,
Some important examples include thethyratron,krytron, andignitron tubes, which are used to switch high-voltage currents. A specialized type of gas-filled tube called agas discharge tube (GDT) is fabricated for use assurge protectors, to limit voltage surges in electrical and electronic circuits.
There were special neon lamps besides nixie tubes:
Tuneon early tuning indicator, a glass tube with a short wire anode and a long wire cathode that glows partially; the glow length is proportional to the tube current
They were filled with a pure inert gas such asneon becausemixtures made the output temperature-dependent. Their burning voltage was under 200 V, but they needed optical priming by an incandescent 2-watt lamp and a voltage surge in the 5-kV range for ignition.
One miniaturethyratron found an additional use as a noise source, when operated as a diode in a transverse magnetic field.[11]
Cathode sputtering is taken advantage of in theTime Totalizer, a metal-vaporcoulometer-based elapsed time meter where the sputtered metal is deposited on a collector element whose resistance therefore decreases slowly.[12]