Bituminous waterproofing

From Wikipedia, the free encyclopedia
(Redirected fromFelt paper)
Roll roofing and waterproofing material
This articleneeds additional citations forverification. Please helpimprove this article byadding citations to reliable sources. Unsourced material may be challenged and removed.
Find sources: "Bituminous waterproofing" – news ·newspapers ·books ·scholar ·JSTOR
(September 2013) (Learn how and when to remove this message)
Replacing the roofing felt on aScout hall inWales

Bituminous waterproofing systems are designed to protect residential and commercial buildings.Bitumen (asphalt orcoal-tar pitch) is a material made up of organic liquids that are highly sticky,viscous, and waterproof.[1] Systems incorporating bituminous-based substrates are sometimes used to constructroofs, in the form of "roofingfelt" or "roll roofing" products.

Roofing felt

[edit]
Not to be confused withtar paper.

Roofing felt (similar to and often confused withtar paper, but historicallymade from recycled rags rather than heavy kraft paper) has been used for decades as waterproof coverings in residential and commercial roofs as an underlay(ment) (sarking) beneath other building materials, particularly roofing and siding materials, and is one type of membrane used in asphaltbuilt up roofing (BUR) systems. Over time the felt's natural mesh used as a substrate for asphalt impregnation (derived from fabrics like cotton or burlap) has evolved into synthetic products performing the same function with improved durability. Other changes with time have enhanced performance, with roofing felt remaining a heavier and more durable product than tar paper.

Function

[edit]

The rapid application of waterproof or water-resistant roofing underlay protects the roof deck during construction until the roofing material is applied and is required for roofs required to meet Underwriters Laboratory (UL) fire ratings. The separation of the roof covering from theroof deck protects the roof covering from resins in some sheathing materials and cushions unevenness and old nails and splinters in re-roofing applications. The underlayment also sheds any water which penetrates the roof covering from an ordinary leak, a leak from wind-driven rain or snow, wind damage to the roof covering, orice dams. However, the application of underlays may increase the roof temperature, which is the leading cause of ageing ofasphalt shingles. Not installing an underlay may void the roof covering warranty.[citation needed]

Weights and grades

[edit]

Felt paper is available in several grades, the most common beingType 1—commonly called 15-pound (15#) or No. 15 (#15)—andType 2—commonly called 30-pound (30#) or No. 30 (#30). The weight designations originated with organic base felt weighing 15 or 30 pounds per 100 sq. ft. (6.8 kg or 14 kg per 9.3 m2). However, modern base felts are made of lighter-weight fibre, so the weight designations, though common colloquially, are no longer literally accurate.[2] A heavier class of materials with a similar construction but designed for civil engineering, environmental protection, and mining applications are known asBituminous Geomembranes (BGMs). BGMs are distinguished in part by larger roll widths which can exceed 5m and substantial thickness of up to 6.0mm.[3]

Another basic designation isorganic orinorganic. Organic felt paper has a base material made with formerly living materials such asrag fibre,hessian (burlap), orcellulose fibres (wood, or jute). Organic felt papers are now considered obsolete, having dwindled to just five percent of the market by 1987.[4] Inorganicbase products arepolyester,glass fibre developed in the 1950s, and historically,asbestos mat. Polyester mat is weaker and less chemically stable than fibreglass but because it is cheap is gaining market share. Polyester mat is primarily used with the more flexible modified-bitumen felt products. Asbestos mat was the first inorganic base material but was outlawed in the 1980s for health reasons but is still in use on some buildings. Inorganic felts are lighter, more tear-resistant, more fire-resistant, and do not absorb water. Another type of felt paper is perforated for use in built-up roofing and is not for use as a water-resistant underlay.

Torch-on bitumen-based waterproofing membrane being rolled out. Tehran Iran

Heavier material is typically used for underlayment of longer-lived roof materials in order to match their longer life span, and on less sloped roofs, which are more susceptible to leaking. For example, two layers of No. 30 felt might be used under a slate or tile roof, whereas a single layer of No. 15 might be adequate for a steeply raked roof of 24-year asphalt shingles.[5]s0

Manufacturing process

[edit]

Roofing felt is manufactured in roll format. Rolls of base felt are pulled on rollers through large tanks of bitumen mixes until they are saturated with thetar-like bitumen mixture, producing rolls of water-resistant but breathable material.

Modified bitumen is mixed with filler components such aslimestone,sand, orpolymers such as atactic polypropylene (APP) that gives rigidity and tear resistance orstyrene-butadiene styrene (SBS), a rubber additive that gives more elastic benefits.[6]

Felt paper standards

[edit]

The American Society for Testing Materials (ASTM) standards that apply to felt paper are:

  • ASTM D226 / D226M Standard — 09: Specification for Asphalt-Saturated Organic Felt Used in Roofing and Waterproofing.[7]
    • Type I - #15 or 15 lb. perforated or non-perforated
    • Type II - #30 or 30 lb. perforated or non-perforated
  • ASTM D4869 / D4869M Standard — Specification for Asphalt-Saturated Organic Felt Underlayment Used in Steep Slope Roofing. ASTM 4869-03 now includes the non-perforated felt referred to in ASTM D226-97a which will be phased out. ASTM 4869-03 includes a liquid-water transmission test (shower test) and dimensional stability limits (wrinkling) which ASTM D226-97a does not include.[8]
    • Type 1 - #8. Formerly ASTM D4869-93 Type I
    • Type 2 - #13. Formerly ASTM D226-97a Type I (No. 15)
    • Type 3 - #20. Formerly ASTM D4869-93 Type II
    • Type 4 - #26. Formerly ASTM D226-97a Type II (No. 30)
  • ASTM D2178 / D2178M-15a Standard — Specification for Asphalt Glass Felt Used in Roofing and Waterproofing.[9]
    • Type IV has a 44-pound breaking strength
    • Type VI has a 66-pound breaking strength
  • ASTM D6757 / D6757M-16a Standard — Specification for Underlayment Felt Containing Inorganic Fibres Used in Steep-Slope Roofing.[10]
  • ASTM D6222 / D6222M-16 Standard — Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet Materials Using Polyester Reinforcements.[11]
    • Type 1
    • Type 2
    • Grade G, surface coated granules
    • Grade S, smooth surface (uncoated)

The Canadian Standards Association standards are:

  • CSA A123.3 Asphalt Saturated Organic Roofing Felt

Roll roofing components

[edit]
Main article:Asphalt roll roofing

Roll roofing is a bitumen product similar toasphalt shingles meant for direct exposure to the weather. To protect its asphaltic base from ultraviolet degradationmineral granules are added on top of the felt, also decreasing the product's fire vulnerability. Thin, removabletransparent film is added to the base of rolled roofing during manufacturing on all torch-on products. This stops the felt from sticking to the mineral layer when rolled up during the packaging process. A similar removable membrane on self-adhesive rolled roofing separates the adhesive from the mineral layer. Torch-on roofing felt also receives a removable membrane to keep it from sticking to itself prior to application.

Irritants

[edit]

The complex chemical composition of bitumen makes it difficult to identify the specific component(s) responsible for adverse health effects observed in exposed workers. Known carcinogens have been found in bitumen fumes generated at work sites. Observations of acute irritation in workers from airborne and dermal exposures to fumes and aerosols and the potential for chronic health effects, including cancer, warrant continued diligence in the control of exposures.

Reasons to use a roofing underlayment

[edit]
  • It protects the roof deck from rain before the roofing is installed.
  • It provides an extra weather barrier in case of blow offs or water penetration through the roofing or flashings.
  • It protects the roofing from any resins that bleed out of the sheathing.
  • It helps prevent unevenness in the roof sheathing from telegraphing through the shingles.
  • It is usually required for the UL fire rating to apply (since shingles are usually tested with underlayment).

Negative aspects

[edit]
  • Bitumen is mostly produced fromcrude oil and is not regarded as a sustainable building product
  • Bitumen is combustible
  • Exposure to extreme heat and UV radiation drastically decreases the lifespan
  • The fumes that are produced during hot application of asphalt or tar can cause dermal and respiratory problems
  • Some felt paper installed on existing buildings may containasbestos, which has acarcinogenic risk if its dust is inhaled.[12]

Malthoid

[edit]

From 1905 to 1988, The Paraffine Paint Co. of San Francisco had Malthoid as a trademark for waterproof and weatherproof building and roofing materials made of paper and felt in whole or in part.[13] However, it had become well known before that.[14] About 1913, Paraffine promoted its Malthoid roofing materials with a 16-page booklet.[15] In 1941, the Duroid Company began making Malthoid inOnehunga,New Zealand.[16]

Malthoid was once common enough to be used as ageneric description of flat roofing material inNew Zealand andSouth Africa (item 26). A description of a New Zealand house built about 1914 says it was, "built of timber framework. covered by sheets of asbestos. The roof was closely timbered, then covered by strips of Malthoid paper. This was then painted with tar and topped off with a sprinkling of sand."[17] Railway vehicles in Australia were roofed with Malthoid.[18] Malthoid is still available for flat roofs and damp courses.[19]

See also

[edit]

References

[edit]
  1. ^"B Glossary Page".Roof Online. Retrieved2016-08-10.
  2. ^Brown, AB; Sparks, JW (1960). "Composition and Rheology of Roofing Asphalt".Symposium on Bituminous Waterproofing and Roofing Materials. pp. 3–17.doi:10.1520/stp38450s.ISBN 978-0-8031-5597-8.
  3. ^Scuero, Alberto; Vaschetti, Gabriella (2010)."Geomembrane sealing systems for dams: ICOLD Bulletin 135".Innovative Infrastructure Solutions.2: 23.doi:10.1007/s41062-017-0089-0.
  4. ^William Cullen, "Transitions in Roofing Technology" National Roofing Contractors' Association"Archived copy"(PDF). Archived fromthe original(PDF) on 2013-05-18. Retrieved2014-03-11.{{cite web}}: CS1 maint: archived copy as title (link) accessed 3/11/2014
  5. ^Joan P. Crowe, "Underlayment considerations: Steep-slope roof systems require different underlay installations".Professional Roofing Magazine May 2005http://www.texasinspector.com/files/Underlayment-NRCA.pdf accessed 3/11/2014
  6. ^Anink, David, and John Mak.Handbook of sustainable building: an environmental preference method for selection of materials for use in construction and refurbishment. Rev. ed. London: James & James, 2004. 62. Print.
  7. ^"Specification for Asphalt-Saturated Organic Felt Used in Roofing and Waterproofing".doi:10.1520/d0226_d0226m-09. ASTM D226 / D226M - 09.{{cite journal}}:Cite journal requires|journal= (help)
  8. ^"Specification for Asphalt-Saturated Organic Felt Underlayment Used in Steep Slope Roofing".doi:10.1520/d4869_d4869m-16a. ASTM D4869 / D4869M - 16a.{{cite journal}}:Cite journal requires|journal= (help)
  9. ^"Specification for Asphalt Glass Felt Used in Roofing and Waterproofing".doi:10.1520/d2178_d2178m-15a. ASTM D2178 / D2178M - 15a.{{cite journal}}:Cite journal requires|journal= (help)
  10. ^"Specification for Underlayment Felt Containing Inorganic Fibers Used in Steep-Slope Roofing".doi:10.1520/d6757_d6757m-16a. ASTM D6757 / D6757M - 16a.{{cite journal}}:Cite journal requires|journal= (help)
  11. ^"Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet Materials Using Polyester Reinforcements".doi:10.1520/d6222_d6222m-16. ASTM D6222 / D6222M - 16.{{cite journal}}:Cite journal requires|journal= (help)
  12. ^Perry, Pat.Health and Safety Questions and Answers a Practical Approach. London: Thomas Telford, 2003. 101. Print.
  13. ^"LegalForce information on trademark". Legalforce.com. Retrieved2014-06-18.
  14. ^"Manawatu Times, Volume XXVII, Issue 7998, 21 June 1904". Paperspast.natlib.govt.nz. 1904-06-21. Retrieved2014-06-18.
  15. ^Powerhouse Museum."93/281/1 Brochure, 'Malthoid Bungalows', paper, The Paraffine Paint Company, USA, c. 1913". Powerhouse Museum, Australia. Retrieved21 September 2013.
  16. ^"Scie Construction Ltd history of flat roofing materials". Scieroofing.com. 2010-02-11. Archived fromthe original on 2014-03-11. Retrieved2014-06-18.
  17. ^Off the Sheep's Back: Bill Richards Lindon Pub., 1986ISBN 0864700148, 9780864700148
  18. ^"photo and some history of Malthoid on Australian heritage railways". Railpage.com.au. Retrieved2014-06-18.
  19. ^"Tremco technical specs"(PDF). Archived fromthe original(PDF) on 2014-02-13. Retrieved2014-06-18.

External links

[edit]
Retrieved from "https://en.wikipedia.org/w/index.php?title=Bituminous_waterproofing&oldid=1270704028#Roofing_felt"
Categories:
Hidden categories:

[8]ページ先頭

©2009-2025 Movatter.jp