This articlemay be too technical for most readers to understand. Pleasehelp improve it tomake it understandable to non-experts, without removing the technical details.(June 2019) (Learn how and when to remove this message) |

Extended X-ray absorption fine structure (EXAFS), along with X-ray absorption near edge structure (XANES), is a subset of X-ray absorption spectroscopy (XAS). Like otherabsorption spectroscopies, XAS techniques followBeer's law. TheX-rayabsorption coefficient of a material as a function of energy is obtained by directing X-rays of a narrow energy range at a sample, while recording the incident and transmitted x-ray intensity, as the incident x-ray energy is incremented.
When the incident x-ray energy matches thebinding energy of anelectron of an atom within the sample, the number of x-rays absorbed by the sample increases dramatically, causing a drop in the transmitted x-ray intensity. This results in an absorption edge. Every element has a set of unique absorption edges corresponding to different binding energies of its electrons, giving XAS element selectivity. XAS spectra are most often collected atsynchrotrons because the high intensity of synchrotron X-ray sources allows the concentration of the absorbing element to reach as low as a few parts per million. Absorption would be undetectable if the source were too weak. Because X-rays are highly penetrating, XAS samples can be gases, solids or liquids.
EXAFSspectra are displayed as plots of the absorption coefficient of a given material versusenergy, typically in a 500 – 1000eV range beginning before anabsorption edge of an element in the sample. The x-ray absorption coefficient is usually normalized to unit step height. This is done by regressing a line to the region before and after the absorption edge, subtracting the pre-edge line from the entire data set and dividing by the absorption step height, which is determined by the difference between the pre-edge and post-edge lines at the value of E0 (on the absorption edge).
The normalized absorption spectra are often calledXANES spectra. These spectra can be used to determine the average oxidation state of the element in the sample. The XANES spectra are also sensitive to the coordination environment of the absorbing atom in the sample. Finger printing methods have been used to match the XANES spectra of an unknown sample to those of known "standards". Linear combination fitting of several different standard spectra can give an estimate to the amount of each of the known standard spectra within an unknown sample.
The dominant physical process in x-ray absorption is one where the absorbed photon ejects a corephotoelectron from the absorbing atom, leaving behind a core hole.[1] The ejected photoelectron's energy will be equal to that of the absorbed photon minus thebinding energy of the initial core state. The atom with the core hole is now excited and the ejected photoelectron interacts with electrons in the surrounding non-excited atoms.
If the ejected photoelectron is taken to have awave-like nature and the surrounding atoms are described as point scatterers, it is possible to imagine thebackscattered electron waves interfering with the forward-propagating waves. The resulting interference pattern shows up as amodulation of the measured absorption coefficient, thereby causing the oscillation in the EXAFS spectra. A simplified plane-wave single-scattering theory has been used for interpretation of EXAFS spectra for many years, although modern methods (like FEFF, GNXAS) have shown that curved-wave corrections and multiple-scattering effects can not be neglected. The photoelectron scattering amplitude in the low energy range (5-200 eV) of the photoelectron kinetic energy become much larger so that multiple scattering events become dominant in theXANES (or NEXAFS) spectra.
Thewavelength of the photoelectron is dependent on the energy and phase of the backscattered wave which exists at the central atom. The wavelength changes as a function of the energy of the incoming photon. Thephase andamplitude of the backscattered wave are dependent on the type of atom doing the backscattering and the distance of the backscattering atom from the central atom. The dependence of the scattering on atomic species makes it possible to obtain information pertaining to the chemical coordination environment of the original absorbing (centrally excited) atom by analyzing these EXAFS data.

The effect of the backscattered photoelectron on the absorption spectra is described by the EXAFS equation, first demonstrated by Sayers, Stern, and Lytle.[2] The oscillatory part of the dipole matrix element is given by, where the sum is over the sets of neighbors of the absorbing atom, is the number of atoms at distance, is thewavenumber and is proportional to energy, is the thermal vibration factor with being the mean square amplitude of the atom's relative displacements, is the mean free path of the photoelectron with momentum (this is related to coherence of the quantum state), and is an element dependent scattering factor.
The origin of the oscillations in the absorption cross section are due to the term which imposes the interference condition, leading to peaks in absorption when the wavelength of the photoelectron is equal to an integer fraction of (the round trip distance from the absorbing atom to the scattering atom). This is analogous to eigenstates of theparticle in a box toy model. The factor inside the is an element dependent phase shift.
Since EXAFS requires a tunable x-ray source, data are frequently collected atsynchrotrons, often atbeamlines which are especially optimized for the purpose. The utility of a particular synchrotron to study a particular solid depends on thebrightness of the x-ray flux at the absorption edges of the relevant elements.
Recent developments in the design and quality of crystal optics have allowed for some EXAFS measurements to take place in a lab setting,[3] where the tunable x-ray source is achieved via a Rowland circle geometry. While experiments requiring high x-ray flux or specialized sample environments can still only be performed at synchrotron facilities, absorption edges in the 5 - 30 keV range are feasible for lab based EXAFS studies.[4]
XAS is an interdisciplinary technique and its unique properties, as compared to x-ray diffraction, have been exploited forunderstanding the details of local structure in:
XAS provides complementary to diffraction information on peculiarities of local structural and thermal disorder in crystalline and multi-component materials.
The use of atomistic simulations such asmolecular dynamics or thereverse Monte Carlo method can help in extracting more reliable and richer structural information.
EXAFS is, likeXANES, a highly sensitive technique with elemental specificity. As such, EXAFS is an extremely useful way to determine the chemical state of practically important species which occur in very low abundance or concentration. Frequent use of EXAFS occurs inenvironmental chemistry, where scientists try to understand the propagation ofpollutants through anecosystem. EXAFS can be used along withaccelerator mass spectrometry inforensic examinations, particularly innuclearnon-proliferation applications.
A very detailed, balanced and informative account about the history of EXAFS (originally called Kossel's structures) is given byR. Stumm von Bordwehr.[5]A more modern and accurate account of the history of XAFS (EXAFS and XANES) is given by the leader of the group that developed the modern version of EXAFS in an award lecture by Edward A. Stern.[6]
{{cite book}}: CS1 maint: location missing publisher (link){{cite book}}: CS1 maint: multiple names: authors list (link) CS1 maint: numeric names: authors list (link){{cite book}}: CS1 maint: others (link){{cite book}}:|work= ignored (help)