This article needs to beupdated. Please help update this article to reflect recent events or newly available information.(August 2016) |
Domestichousing in the United Kingdom presents a possible opportunity for achieving the 20% overall cut inUK greenhouse gas emissions targeted by the Government for 2010. However, the process of achieving that drop is proving problematic given the very wide range of age and condition of the UK housing stock.
Although carbon emissions from housing have remained fairly stable since 1990 (due to the increase in household energy use having been compensated for by the 'dash for gas'), housing accounted for around 30% of all the UK'scarbon dioxide emissions in 2004 (40 million tonnes of carbon)[1] up from 26.42% in 1990 as a proportion of the UK's total emissions.[2] TheSelect Committee on Environmental Audit noted that emissions from housing could constitute over 55% of the UK's target for carbon emissions in 2050.[1]
A 2006 report commissioned byBritish Gas[3] estimated the average carbon emissions for housing in each of the local authorities inGreat Britain, the first time that this had been done. This indicated that housing inUttlesford (Essex) produced the highest emissions (8,092 kg of carbon dioxide per dwelling). This was 250% higher than housing inCamden (London) which produced the least (averaging 3,255 kg). Among the 23 towns included,Reading had the highest emissions (6,189 kg), withHull the lowest (4,395 kg). The variations are due to a number of factors, including the age, size and type of the housing stock, together with the efficiency of heating systems, the mix of fuels used, the ownership of appliances, occupancy levels and the habits of the occupants.
In the December 2006Pre-Budget Report,[4] the Government announced their 'ambition' that all new homes will be 'zero-carbon' by 2016 (i.e. built tozero-carbon building standards). To encourage this, an exemption fromStamp duty land tax was to be granted, lasting until 2012, for all new zero-carbon homes up to £500,000 in value.[5]
Whilst some organisations applauded the initial announcement of the scheme, in the pre-budget statement from the then UK Chancellor, Gordon Brown, others are concerned about the government's ability to deliver on the promise.[6][7]
In 2003 the housing stock in the United Kingdom was amongst the least energy efficient in Europe.[8] In 2004, housing (including space heating, hot water, lighting, cooking, and appliances) accounted for 30.23% of all energy use in the UK (up from 27.70% in 1990).[9] The figure forLondon is higher at approximately 37%.[10]
In view of the progressive tightening of theBuilding Regulations' requirements for energy efficiency since the 1970s (see the history section below), it might be expected that a significant cut in domestic energy use would have occurred, however this has not yet been the case.
Althoughinsulation standards have been increasing, so has the standard of home heating. In 1970, only 31% of homes hadcentral heating. By 2003 it had been installed in 92% of British homes,[11] leading in turn to a rise in the average temperature within them (from 12.1 °C to 18.20 °C).[12] Even in homes with central heating, average temperatures rose 4.55 °C during this period.
At the same time, the increase in the number of households, increasing numbers of domestic electrical appliances, an increase in the number of light fittings, reduction in the average number of occupants per household, plus other factors, had led to an increase in total nationaldomestic energy consumption from around 25% in 1970 to about 30% in 2001, and remained on an upward trend (BRE figures).
The figures for energy consumed by end use for 2003.[13]
The Green Deal provided low interest loans forenergy efficiency improvements to the energy bills of the properties the upgrades are performed on.[14] These debts are passed onto new occupiers when they take over the payment of energy bills. The costs of the loan repayments should be less than the savings on the bills from the upgrades, however this will be a guideline and not legally enforceable guarantee. It is believed that tying repayment to energy bills will give investors a secure return.The Green Deal for the domestic property market was launched in October 2012. The Commercial Green Deal was launched in January 2012 and released in a series of stages to help with the varying needs and requirements of commercial properties.

The 1965 Building Regulations[15] introduced the first limits on the amount of energy that could be lost through certain elements of the fabric of new houses. This thermal performance was expressed in the imperial units of the time (the amount of heat in BTU lost per square foot, for each degree Fahrenheit of temperature difference between inside and outside).The 1965 regulations were the first set of truly nationwide standards, prior to this local authorities set their own local regimes. Part F of the 1965 regulations defines minimum thermal performance, and schedule 11 of the same document gives examples of compliant methods for builders and architects to refer to. While novel at the time, by modern standards these limits set quite a low target, unfilledcavity walls, 2 inches of loft insulation and uninsulated concrete floors were deemed adequate for the reference standards. The 1972 regulations[16] retained the same standards but converted to metric units (mm) and the modernu-value (the amount of heat lost per square metre, for each degree Celsius of temperature difference between inside and outside).
In effect, the Target Insulation was u-values of 1.42 W/m2·K for the roof and floor and 1.7 W/m2·K for external walls. Modern performance standards require values less than 20% of this. Thisu-value approach is slightly regressive in that richer people live in bigger houses which tend to have a lower ratio of surface area to floor area, although they are often detached, which can offset the advantage over smaller row houses.
These first limits were tightened following the1973 oil crisis, and on several subsequent occasions, including the addition of limits for doors and windows in the year 2000 that effectively requireddouble glazing for the first time. (seebelow). Despite this, UK insulation levels have been introduced later or remained lower compared to theEU average.[17]
Theenergy policy of the United Kingdom through the 2003 Energy White Paper[18] articulated directions for more energy efficient building construction. Hence, the year 2006 saw a significant tightening ofenergy efficiency requirements within the Building Regulations (for earlier regulations, see separate sectionbelow).
With the long-term aim of cutting overall emissions by 60% by 2050, and by 80% by 2100, the intention of the 2006 changes was to cut energy use in new housing by 20% compared to a similar building constructed to the 2002 standards. The changes were the first to the regulations brought about by the desire to reduce emissions, though some have raised doubts about whether they will actually achieve the 20% cut (see criticisms section).
In the 2006 regulations, the u-value was replaced as the primary measure of energy efficiency by the Dwelling Carbon Dioxide Emission Rate (DER),[19] an estimate of carbon dioxide emissions per m2 of floor area. This is calculated using the Government's Standard Assessment Procedure for Energy Rating of Dwellings (SAP 2005).[20]
In addition to the levels of insulation provide by the structure of the building, the DER also takes into account the airtightness of the building, the efficiency of space and water heating, the efficiency of lighting, and any savings fromsolar power or other energy generation technologies employed, and other factors. For the first time, it also became compulsory to upgrade the energy efficiency in existing houses when extensions or certain other works are carried out.
Some organisations have raised doubts over the claim that the changes will result in a 20% saving. Issues cited have included alleged problems with the calculation methods, the limitations of the modelling software, and the specification of the reference building used in the model.[21] For example, a 2005 study sponsored by the Pilkington Energy Efficiency Trust[22] indicated that the savings would only be in the region of 9%.[23]
There are also concerns about enforcement, with aBuilding Research Establishment study in 2004 indicating that 60% of new homes do not conform to existing regulations.[24] A 2006 survey for theEnergy Saving Trust revealed thatBuilding Control Officers considered energy efficiency 'a low priority' and that few would take any action over failure to comply with the Building Regulations because the matter 'seemed trivial'.[25][26]
In December 2006, the government announced their ambition that all new housing should be built tozero-carbon standards from 2016;[27] i.e., that the carbon emitted during a typical year should be balanced byrenewable energy generation. Despite being the first country in the world to adopt such a policy[28] the initiative was generally welcomed by the industry in principle,[29] despite some subsequent concern over the practicalities.[30][31]
On 1 April 2011 theWWF resigned from the taskforce on Zero-Carbon homes,[32] stating that 'the zero-carbon policy is now in tatters' after the Government unilaterally decided to change the scope of the 'zero carbon' policy to exclude some emissions[33] not currently covered by the building regulations. TheUK Green Building Council estimated that the change, published at the time of the March 2011 budget, will result in only two-thirds of the emissions of a new home being mitigated.[34]
In 2004, the Government indicated that the next revision to the energy performance standards of the Building Regulations would be in 2010.[35] In the consultation documentBuilding a Greener Future: Towards Zero Carbon Development it was proposed that the 2010 revision should require a further 25% improvement in the energy/carbon performance, in line with the 2004 proposals.[36] It was further envisaged that there would be a 44% improvement in 2013, compared to 2006 levels. This would then be followed by the adoption of a zero carbon requirement in 2016, applied to all home energy use including appliances.[36] These steps in performance would align the energy efficiency requirement of the Building Regulations with those of Levels 3, 4 and 6 of theCode for Sustainable Homes in 2010, 2013 and 2016 respectively.[37]
Originally, from June 2007, all homes (and other buildings) in the UK would have to undergoEnergy Performance Certification (also commonly known as an EPC Certificate) before they are sold or let,[38] in order to meet the requirements of theEuropean Energy Performance of Buildings Directive (Directive 2002/91/EC).[39] The scheme provides the owner or landlord with an 'energy label' so that they can demonstrate the energy efficiency of the property, and is also included in the newHome Information Packs. The scheme has been criticized for its methodology and superficial approach, especially for old buildings. For example, it ignores thick walls with their low heat transmission, and its recommendations forcompact fluorescent lamps, which can damage sensitivetextiles andpaintings.
It is hoped that energy labelling will raise awareness of energy efficiency, and encourage upgrading to make properties more marketable. Incentives may be available for carrying out energy conservation measures.[40] Research by comparethemarket.com showed homes across the UK were worth more when scored highly in an EPC.[41][42]
For new building, SAP calculations are to form the basis for the certification, while RDSAP (Reduced Data SAP) will be used to assess existing properties. It is estimated that only 10% of the nation's housing will score above 60 on the scale, although most will score above 40.[43]
Another rating scheme of note is the Government sponsoredEcoHomes rating, mostly used inpublic sector housing, and only applicable to new properties or major refurbishments. This actually measures a range of sustainability issues, of which energy efficiency is only one. EcoHomes is to be replaced by the Government'sCode for Sustainable Homes in 2007.
TheEnergy Saving Trust set requirements for 'good practice' and 'advanced practice' for achieving lower energy buildings,[44] while theAssociation for Environment Conscious Building'sCarbonLite programme specifies Silver and Gold standards, the latter approaching azero energy building.
In Wales, where 'zero-carbon homes' are the aspiration for 2011 (although 2012 is more likely), the requirements are for Code for Sustainable Homes or equivalent. This has opened the doors for standards like Passiv Haus and the CarbonLite programme. Another lesser known building type that does not rely on airtightness in order to get its energy rating is Bio-Solar-Haus. This is not a well known type of house, but it has a range of positive advantages like it is built out of renewable resources and it is a breathable structure thus making it much healthier to live in.

The Government'slow carbon buildings programme was launched in 2006 to replace the earlierClear Skies andSolar PV programmes. It offers grants towards the costs ofsolar thermal heating,small wind turbine,micro hydro,ground source heat pump, andbiomass installations. As of January 2007 funding for grants is proving insufficient to meet demand.[45]
A similar scheme, theScottish Community and Household Renewables Initiative operates inScotland, which also offers grants towards the cost ofair source heat pumps.
Under theHome Energy Conservation Act 1995,local authorities are required to consider measures to improve the energy efficiency of all residential accommodation in their areas, although they are not required to implement any measures. Most local authorities provide free advice on energy conservation and some also provide home visits, often targeting those in social housing and thefuel poor. Some also demand minimum levels of energy efficiency in newly constructed buildings. It was expected that the Act would result in a 30% cut in energy usage between 1996 and 2010. An overall cumulative improvement of 14.7% was reported to DEFRA for the year ending March 2004, but a large part of this would have happened without HECA.[46]
In the South,[citation needed] most local authority housing was sold off in the 1980s-90s under RTB (Right to buy scheme), so the remaining stock is small. Much social housing has also been transferred tohousing associations.
One of the most important energy efficiency demonstration projects was the 1986Energy World exhibition inMilton Keynes, which attracted international interest. Fifty-one houses were built, designed to be at least 30% more efficient than the Building Regulations then in force. This was calculated using the Milton Keynes Energy Cost Index (MKECI), a test-bed for the subsequent SAP rating system and theNational Home Energy Rating scheme. Energy World was preceded by the earlierSalford low-energy houses, built in the early 1980s, which continue to be 40% more efficient than the 2010 Building Regulations.[47]
The Beddington Zero Energy Development (BedZED), a non-traditional housing scheme of 82 dwellings nearBeddington, London included zero fossil energy usage as one of its key design features. The project was completed in 2002 and is the UK's largest eco-development. As designed, the energy used is generated fromrenewables on site. In use, BedZED has yielded considerable useful feedback, not least that energy efficiency and passive design features delivery more reliable reduced carbon emissions than active systems. Due to theirsuperinsulation, the properties use 88% less energy (measured) for space heating compared to those built to the 2002 Building Regulations, while the reduction for water heating is 57%. Measured electrical use for cooking, appliances and occupant's plug loads ('unregulated energy' consumption) are some 55% lower than UK norms (bedzed-seven-years-on).[48]
The Green Building inManchester City Centre and has been built to high energy efficiency standards and won a 2006 Civic Trust Award for its sustainable design.[49] Thecylindrical shape of the ten-storey tower provides the smallest surface area related to the volume, ensuring less energy is lost through thermaldissipation. Other technologies includingsolar water heating, awind turbine and triple glazing.
TheSouth Yorkshire Energy Centre atHeeley City Farm inSheffield is an example of refurbishing an existing property to show the options available.[50]
The EcoHouse in Leicester[51] is to be renovated in 2011 to provide a demonstration ofRetrofit for the Future energy efficiency standards.[52]
TheOld Home SuperHome initiative features many owner occupied, existing home retrofits which achieve a 60% carbon saving which can be visited by the public.[53] Many of the homes have dramatically improved their energy efficiency to achieve these carbon savings, while some have also installed renewable energy technologies.
International comparisons of particular note include:
Since then many more have been built in Canada, inJapan, and in various other countries including a number in the UK. Currently energy savings of 30% to 40% are typically achieved in Canada.[56]
In 2005, the Select Committee on Environmental Audit expressed their concern that there was a lack of significant funding for research and development of sustainable construction methods,[58] with funding for theBuilding Research Establishment having been "drastically" cut in the previous 4 years. As a result, many of the sustainable building materials used in the UK are imported fromGermany,Switzerland andAustria—some of the countries that have been prominent in research.
Even if all new housing does become zero carbon by 2016, the energy efficiency of the remainder of the housing stock would need to be addressed.
The 2006Review of the Sustainability of Existing Buildings revealed that 6.1 million homes lacked an adequate thickness of loft insulation, 8.5 million homes had uninsulated cavity walls, and that there is a potential to insulate 7.5 million homes that have solid external walls. These three measures alone have the potential to save 8.5 million tonnes of carbon emissions each year. Despite this, 95% of homeowners think that the heating of their own home is currently effective.[59]
SeeUK Government policy for improving home energy efficiency for further information on policies from 1945 to 2016 and their effectiveness.
| Year | Minimum depth |
|---|---|
| 1965 | 25 mm |
| 1975 | 60 mm |
| 1985 | 100 mm |
| 1990 | 150 mm |
| 1995 | 200 mm |
| 2002 | 250 mm |
| 2003 | 270 mm |
The u-value limits introduced in1965 were:[61]
Following the1973 oil crisis, these were tightened in1976 to:[62]
1985 saw the second tightening of these limits, to:
These limits were reduced again in1990:
Like the 2006 changes, it was predicted that the introduction of these limits would result in a 20% reduction in energy use for heating. A survey byLiverpool John Moores University predicted that the actual figure would be 6%(Johnson, JA "Building Regulations Research Project").
In the1995 Building Regulations, insulation standards were cut to the following U-values:
The2002 regulations reduced the U-values, and made additional elements of the building fabric subject to control. Although there was in practice considerable flexibility and the ability to 'trade off' reductions in one area for increases in another, the 'target' limits became:
Similar limits were introduced intoScotland in 2002 & 2006, though with a lower limit of 0.3 or 0.27 for walls, and some other variations.
It was claimed by Government that these measures should cut the heating requirement by 25%[63] compared to the 1995 Regulations. It was subsequently also claimed that they had achieved a 50% cut compared to the 1990 Regulations.[64]
While the u-value ceased being the sole consideration in2006, u-value limits similar to those in the 2002 regulations still apply, but are no longer sufficient by themselves. The DER, and TER (Target Emission rate) calculated through either the UK Government's Standard Assessment Procedure for Energy Rating of Dwellings (SAP rating), 2005 edition, or the newer SBEM (*Simplified Building Energy Model) which is aimed at non-dwellings, became the only acceptable calculation methods. Several commercial energy modeling software packages have now also been verified as producing acceptable evidence by the BRE Global & UK Government. Calculations using previous versions of SAP had been an optional way of demonstrating compliance since 1991(?). They are now a statutory requirement (B. Reg.17C et al.) for all building regulations applications, involving new dwelling/buildings and large extensions to existing non-domestic buildings.
{{cite web}}: CS1 maint: archived copy as title (link){{cite web}}: CS1 maint: archived copy as title (link){{cite web}}: CS1 maint: archived copy as title (link)