      AIM: To assess the safety, efficacy, predictability and stability of implantable collamer lens (ICL) for residual refractive error after corneal refractive surgery. METHODS: This study evaluated 19 eyes of 12 patients who underwent ICL implantation after corneal refractive surgeries. They were followed up for 1y to 5y of uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest refractive error, flat and steep K value, axial length, intraocular pressure, corneal endothelial cell density, adverse events after ICL surgery. RESULTS: The mean follow-up period was 39.05±19.22 mo (range, 1-5y). Spherical equivalent refractive error changed from -7.45±3.02 D preoperatively to -0.85±1.10 D 1wk to 1mo after ICL implantation, with the safety and efficacy indices being 1.12 and 1.15, respectively. A total of 52.63% of eyes were within ±0.5 D of the predicted spherical equivalents, 73.68% were within ±1.0 D. A trend of mild regression towards myopia with axial elongation after 5y was observed. One eye with mild anterior capsule opacity and retinal detachment 1y after surgery were observed. CONCLUSION: ICL implantation is safe and effective for the correction of residual refractive error after corneal refractive surgeries, especially in moderate to high residual myopia.

      Reference
      Related
      Cited by
    Get Citation

    Xun Chen, Xiao-Ying Wang, Xi Zhang, et al. Implantable collamer lens for residual refractive error after corneal refractive surgery. Int J Ophthalmol, 2016,9(10):1421-1426

    Copy
    Share
    0
    Article Metrics
    • Abstract:
    • PDF:
    • HTML:
    • Cited by:
    Publication History
    • Received:December 16,2015
    • Revised:June 29,2016
    • Adopted:
    • Online:October 13,2016
    • Published:
    You are the  Visitors
    Governing Body:Department of Health, Provincial Government of Shaanxi, China
    Organizer:Xi'an Medical Association of China
    Address:Room 11707-08, Building 2, Unit 1, Wanda Plaza, No.8 Yanta North Road, Xi'an 710054, Shaanxi Province, China
    Fax:(8629)82245172Phone:(+8629)82245172/82210956
    Email:ijopress@163.com
    International Journal of Ophthalmology ® 2025 All Rights Reserved   The terms of CC BY-NC-ND 4.0 are applicable to all open access content.

    [8]ページ先頭

    ©2009-2025 Movatter.jp