Observations of hemodynamics during human cardiopulmonary resuscitation

CHANDRA, NISHA CHIBBER MD; TSITLIK, JOSHUA E. PHD; HALPERIN, HENRY R. MD; GUERCI, ALAN D. MD; WEISFELDT, MYRON L. MD

Author Information

Division of Cardiology, Department of Medicine, Francis Scott Key Medical Center, and The Johns Hopkins Hospital, Baltimore, MD.

Critical Care Medicine18(9):p 929-934, September 1990.

Abstract

To evaluate hemodynamics during human CPR, 32 patients with witnessed cardiac arrest were studied during manual and mechanical conventional CPR. In eight patients during manual conventional CPR, peak systolic radial artery, right atrial (RAP), and pulmonary artery pressures were found to be similar (59.8 ± 4.3, 70.8 ± 4.7, 71.2 ± 8.2 mm Hg) and higher than external jugular venous pressure (33.8 ± 1.9 mm Hg,p <.0001). The diastolic radial artery to RAP gradient was found to be only 10.7 ± 2.1 mm Hg. In four patients, maneuvers that avoid chest compression and thus obviate cardiac compression, i.e., rhythmic compression of the abdomen, yielded arterial pressures comparable to those generated by conventional CPR (48 ± 6.4 vs. 52.8 ± 3.4 mm Hg, NS). In 13 other patients during mechanical conventional CPR at constant chest compression force, radial artery pressure was higher during the rust compression after ventilation as compared with subsequent chest compressions (67.5 ± 5.0 vs. 61.9 ± 4.8 mm Hg,p <.007). These hemodynamic observations are similar to those reported in large dogs during CPR and support the generation of vascular pressures during CPR by an increase in intrathoracic pressure. They also suggest that despite anatomic differences, the similarity of hemodynamics in dogs and humans justifies the use of large dogs as a human model during acute resuscitation studies.

© Williams & Wilkins 1990. All Rights Reserved.

You can read the full text of this article if you:

Log InAccess through Ovid

Source

Critical Care Medicine18(9):929-934, September 1990.
Email to Colleague

Colleague's E-mail is Invalid

Your Name:
Colleague's Email:
Separate multiple e-mails with a (;).
Message:

Your message has been successfully sent to your colleague.



Some error has occurred while processing your request. Please try after some time.


[8]ページ先頭

©2009-2026 Movatter.jp