- Jarno Riistama1,
- Juho Väisänen2,
- Sami Heinisuo3,
- Hanna Harjunpää4,
- Satu Arra3,
- Kati Kokko3,
- Maunu Mäntylä3,
- Jutta Kaihilahti5,6,
- Pekka Heino3,
- Minna Kellomäki4,
- Outi Vainio5,
- Jukka Vanhala3,
- Jukka Lekkala1 &
- …
- Jari Hyttinen2
886Accesses
38Citations
Abstract
The development of an active implantable device for measuring electrocardiogram (ECG) is presented. The study is a part of a project which aims at developing implantable ECG instrumentation with wireless data and power transfer (http://www.ele.tut.fi/tule). The developed implant presented here has all the measurement electronics as well as power and data communication instrumentation included. The implant itself contains no battery, while power for the implant is transferred electromagnetically from an external reader device. The results of testing the implant attached on the body surface and in vitro in a water container are also presented. The developed system was also successfully tested in in vivo measurements, which were conducted on four cows with an implantation time of 24 h. The in vivo testing of implant in cows was conducted by a veterinarian in supervised conditions under approved animal experiment licence.
This is a preview of subscription content,log in via an institution to check access.
Access this article
Subscribe and save
- Get 10 units per month
- Download Article/Chapter or eBook
- 1 Unit = 1 Article or 1 Chapter
- Cancel anytime
Buy Now
Price includes VAT (Japan)
Instant access to the full article PDF.









Similar content being viewed by others
References
Atmel Corporation (2003) U2270B Read/Write Base Station. Datasheet
Atmel Corporation (2003) U2270B application note—electronic immobilizers for the automotive industry
Atmel Corporation (2003) U3280M transponder interface for microcontroller. Datasheet
Alonso M, Finn EJ (1983) Fundamental university physics, vol II, 2nd edn. Addison-Wesley, Reading
Boersma L, Mont L, Sionis A, Garcia E, Brugada J (2004) Value of the implantable loop recorder for the management of patients with unexplained syncope. Europace 6:70–76
Campell PK, Jones KE (1992) Materials for implantable electrodes and electronic devices materials science and technology. In: Cahn RW, Hansen P, Kramer EJ (eds) A comprehensive treatment. VCH, Weinheim, pp 345–372
Chrysostomakis SI, Klapsinos NC, Simantirakis EN, Marketou ME, Kambouraki DC, Vardas PE (2003) Sensing issues related to the clinical use of implantable loop recorders. Europace 5:143–148
Claes W, Puers R, Sansen W, De Cooman M, Duyck J, Naert I (2002) A low power miniaturized autonomous data logger for dental implants. Sens Actuators A Phys 97-8:548–556
Farwell DJ, Freemantle N, Sulke AN (2004) Use of implantable loop recorders in the diagnosis and management of syncope. Eur Heart J 25:1257–1263
Finkenzeller K (2003) RFID handbook—fundamentals and applications in contactless smart cards and identification. Wiley, New York
Heinisuo S, Vanhala J (2006) Wireless platform for multi-channel analog measurements. In: Proceedings of 28th annual international conference, IEEE Engineering in Medicine and Biology Society, New York, pp 5908–5911
Johnson CR (1997) Computational and numerical methods for bioelectric field problems. Crit Rev Biomed Eng 25:1–81
Jutley RS, Shepherd DE, Hukins DW, Jeffrey RR (2003) Preliminary evaluation of the sternum screw: a novel method for improved sternal closure to prevent dehiscence. Cardiovasc Surg 11:85–89
Malmivuo J, Plonsey R (1995) Bioelectromagnetism: principles and applications of bioelectric and biomagnetic fields. Oxford University Press, New York
microIDTM (1998) 125 kHz RFID system design guide. Microchip Technology Inc
Mokwa W, Schnakenberg U (2001) Micro-transponder systems for medical applications Instrumentation and Measurement. IEEE Trans 50:1551–1555
Riistama J, Väisänen J, Heinisuo S, Lekkala J, Hyttinen J (2005) Introducing a wireless, passive and implantable device to measure ECG. In: IFMBE proceedings of the 3rd European medical and biological engineering conference, IFMBE, Prague
Riistama J, Lekkala J (2006) Electrode–electrolyte interface properties in implantation conditions proc. Engineering in Medicine and Biology Society, 2006. In: 28th annual international conference of the IEEE, pp 6021–6024
Riistama J, Lekkala J (2006) Electrical properties of electrodes in implantation conditions (unpublished)
Song Z, Jenkins J, Burke M, Arzbaecher R (2004) The feasibility of ST-segment monitoring with a subcutaneous device. J Electrocardiol 37(Suppl):174–179
Sörnmo L, Laguna P (2005) Bioelecrical signal processing in cardiac and neurological applications. Elsevier Inc., London, p 668
Takahata K, DeHennis A, Wise KD, Gianchandani YB (2003) Stentenna: a micromachined antenna stent for wireless monitoring of implantable microsensors proc. Engineering in Medicine and Biology Society. In: Proceedings of the 25th annual international conference of the IEEE, pp 3360–3363
Vehkaoja A, Lekkala J (2004) Wearable wireless biopotential measurement device. In: Proceedings of 26th annual international conference of the IEEE Engineering in Medicine and Biology Society, pp 2177–2179
Vehkaoja A and Lekkala J (2006) Wireless measurement band for EEG mismatch negativity registration in mobile activities. In: Proceedings of XVIII IMEKO world congress: metrology for a sustainable development, Rio de Janeiro, Brazil
Väisänen J, Hyttinen J, Puurtinen M, Kauppinen P, Malmivuo J (2004) Prediction of implantable ECG lead systems by using thorax models. In: Proceedings of Engineering in Medicine and Biology Society. Proceedings of the 26th annual international conference of the IEEE, pp 809–812
Väisänen J, Hyttinen J, Malmivuo J (2006) Finite difference and lead field methods in designing of implantable. ECG Monit 44:857–864
Zhang F, Zheng Z, Chen Y, Liu X, Chen A, Jiang Z (1998) In vivo investigation of blood compatibility of titanium oxide films. J Biomed Mater Res 42:128–33
Yamagishi FG (1991) Investigation of plasma-polymerized films as primers for parylene-c coatings on neural prosthesis. Materials Thin Solid Films 202:39–50
Author information
Authors and Affiliations
Institute of Measurement and Information Technology, Tampere University of Technology, Tampere, Finland
Jarno Riistama & Jukka Lekkala
Ragnar Granit Institute, Tampere University of Technology, Tampere, Finland
Juho Väisänen & Jari Hyttinen
Institute of Electronics, Tampere University of Technology, Tampere, Finland
Sami Heinisuo, Satu Arra, Kati Kokko, Maunu Mäntylä, Pekka Heino & Jukka Vanhala
Institute of Biomaterial, Tampere University of Technology, Tampere, Finland
Hanna Harjunpää & Minna Kellomäki
MTT Agrifood Research Finland, Animal Production Research, Jokioinen, Finland
Jutta Kaihilahti & Outi Vainio
Faculty of Veterinary Medicine, Department of Clinical Veterinary Sciences, University of Helsinki, Helsinki, Finland
Jutta Kaihilahti
- Jarno Riistama
You can also search for this author inPubMed Google Scholar
- Juho Väisänen
You can also search for this author inPubMed Google Scholar
- Sami Heinisuo
You can also search for this author inPubMed Google Scholar
- Hanna Harjunpää
You can also search for this author inPubMed Google Scholar
- Satu Arra
You can also search for this author inPubMed Google Scholar
- Kati Kokko
You can also search for this author inPubMed Google Scholar
- Maunu Mäntylä
You can also search for this author inPubMed Google Scholar
- Jutta Kaihilahti
You can also search for this author inPubMed Google Scholar
- Pekka Heino
You can also search for this author inPubMed Google Scholar
- Minna Kellomäki
You can also search for this author inPubMed Google Scholar
- Outi Vainio
You can also search for this author inPubMed Google Scholar
- Jukka Vanhala
You can also search for this author inPubMed Google Scholar
- Jukka Lekkala
You can also search for this author inPubMed Google Scholar
- Jari Hyttinen
You can also search for this author inPubMed Google Scholar
Corresponding author
Correspondence toJarno Riistama.
Rights and permissions
About this article
Cite this article
Riistama, J., Väisänen, J., Heinisuo, S.et al. Wireless and inductively powered implant for measuring electrocardiogram.Med Bio Eng Comput45, 1163–1174 (2007). https://doi.org/10.1007/s11517-007-0264-0
Received:
Accepted:
Published:
Issue Date:
Share this article
Anyone you share the following link with will be able to read this content:
Sorry, a shareable link is not currently available for this article.
Provided by the Springer Nature SharedIt content-sharing initiative