Control signal calculations

In my last post I translated BAL commands into control signals for the BPU. It's now time to implement the logic generating these signals and all the parts will be ready to be put together.

Recap

Last time on Esoposting

In the previous episode I came up with the following list of translations from BAL commands to BPU signals:

Every command0. PC->A; MEM->D; D->PR;+/-1. DP->A; MEM->D; D->ALU; PC++;2. DP->A; ALU->D; D->MEM;>/<1. DP->D; D->ALU; PC++;2. ALU->D; D->DP;[/]1. PC->D; D->ALU; PC++;2. DP->A; ALU->D; D->PC;,1. DP->A; I/O; D->MEM; PC++;2. Next Command;.1. DP->A; MEM->D; I/O; PC++;2. Next Command;
Enter fullscreen modeExit fullscreen mode

Commands run for three clock cycles except for I/O commands that run for two cycles and will need a "Next Command" signal to immediately reset the cycle counter to 0.

Cycle counter

Command Decoder abstract

As shown above the Command Decoder needs to keep track of clock cycles to create correct signal combination. This could be achieved using a 2-bit counter, but I prefer to use a 2-bit shift register. It's a type of register that moves its contents one bit to the right every clock cycle, discarding the rightmost bit and taking the new leftmost bit from input.

This solution is almost identical (just mirrored) to the counter for 3-cycle commands:00 on cycle 0,10 on cycle 1 and01 on cycle 2. The advantage of the shift register is that if for any reason the cycle continues past these two states, the counter enters its fourth state:11, while the shift register resets back to00 by itself making it a bit safer and easier to wire up.

cycle counter circuit

Circle counter in Logisim

The shift input of the register should be 1 when the register is at00 to make the transition00 -> 10 and 0 at other times, which can be accomplished by taking aNOR of the registers contents and theLoad signal. ThisNOR output also indicates the 0th cycle, so theLoad signal is here to disable it when loading.

The other register input that I care about is "reset". There are three situations where the cycle count should reset: when the whole machine is reset, on the third cycle of I/O commands and when loading data from ROM. Signals regarding each of these instances should beORed together for the "reset" input of the register.

The register also needs to connect to the clock for synchronisation. Usually it's as simple as connecting a wire to an input, but here it requires a twist. The signals generated by the command decoder govern the data flow inside the BPU. Nothing in electronics can happen in the same instant. Because of physical constraints every action happening in the computer can get delayed by several nanoseconds. If data transfer is designed to happen at the same time as the control signal change then some actions will take place with the old control signals in place while other will act according to the new signals, resulting in a wrong action and breaking the system. To prevent that, the clock signal is inverted inside the command decoder. This means command change happens at the falling edge of the clock while data transfer happens on the rising edge, ensuring that nothing breaks.

Decoding the signals

What we came here for

With the cycle counter done I have all inputs necessary to decode the signals. Each signal is a simple boolean function of the command and the cycle count. I will start each signal with a table indicating at which inputs it should be on (1), when it should be off (0) and when it doesn't matter (-). In these tables the BAL commands will be listed in an unconventional way, such that binary representations of neighbouring commands vary only by one bit. It makes it easier to create boolean functions based on these tables.

Command+-<>,.][
Decimal01326754
Binary000001011010110111101100

D->ALU

T+-<>,.][
000001011010110111101100
0--------
11111--11
2--------
L--------

Because ALU never stores data over more than one clock cycle it doesn't matter if it takes value from the bus or not, unless it's required to perform addition. TheD->ALU signal can be just tied high all the time.

D->ALU = 1
Enter fullscreen modeExit fullscreen mode

D into ALU function

D->ALU signal function in Logisim

ALU->D

T+-<>,.][
000001011010110111101100
000000000
100000000
21111--11
L00000000

UnlikeD->ALU this signal puts data on the Data Bus, so it has a lot of restrictions on when it can't be high. Fortunately, because the second cycle on I/O commands doesn't exist, this arrangement of ones allows to connect the signal directly to the second cycle.

ALU->D = T2
Enter fullscreen modeExit fullscreen mode

ALU into D function

ALU->D signal function in Logisim

D->PR

T+-<>,.][
000001011010110111101100
011111111
100000000
20000--00
L--------

The Program Register is updated with a new command on each zeroth cycle, which means it can be directly connected to it.

D->PR = T0
Enter fullscreen modeExit fullscreen mode

D into PR function

D->PR signal function in Logisim

MEM->D

T+-<>,.][
000001011010110111101100
011111111
111000100
20000--00
L00000000

This signal is a bit more complicated. Not only it should be on during the zeroth cycle but also on the first cycle for add, subtract and output commands.

MEM->D = T0 OR (T1 AND ~C0 AND ~C1) OR (T1 AND C0 AND C1 AND ~C2)
Enter fullscreen modeExit fullscreen mode

Mem to D function

MEM->D signal function in Logisim

D->MEM

T+-<>,.][
000001011010110111101100
0--------
1--001-00
21100--00
L11111111

This signal only has to be on during the second cycle of the add/sub commands, the first cycle of the input command and during loading, but it can also be on whenever MEM->D is on overwriting the data in the memory with itself. Using some of those- fields as ones allows for much simpler functions.

D->MEM = L OR (~C0 AND ~C1) OR (C0 AND C1)
Enter fullscreen modeExit fullscreen mode

D into Mem function

D->MEM signal function in Logisim

DP->D

T+-<>,.][
000001011010110111101100
000000000
100110000
20000--00
000000000

As another signal that outputs data onto the Data BusDP->D has a very strict table with no-. It can only be on during the first cycle of the pointer moving commands.

DP->D = T1 AND ~C0 AND C1
Enter fullscreen modeExit fullscreen mode

DP into D function

DP->D signal function in Logisim

D->DP

T+-<>,.][
000001011010110111101100
000000000
100--0000
20011--00
L00000000

As withD->MEM,D->DP can be on whenDP->D is on, but it doesn't help much in this case. The- in the I/O commands on the other hand help minimise this function. The smallest function is whenD->DP is on during the second cycle of the pointer moving commands and I/O commands, because the latter never occurs.

D->DP = T2 AND C1
Enter fullscreen modeExit fullscreen mode

D into DP function

D->DP signal function in Logisim

DP->A

T+-<>,.][
000001011010110111101100
000000000
111--11--
211----11
L00000000

There are only two signals that output to the Address Bus:DP->A andPC->A, which means that whenever one is off the other can
be on. This leads to the simplest solution:PC->A is on during loading and the zeroth cycle, andDP->A is on during first and second cycles.

DP->A = T1 OR T2
Enter fullscreen modeExit fullscreen mode

DP into A function

DP->A signal function in Logisim

PC->D

T+-<>,.][
000001011010110111101100
000000000
100000011
20000--00
000000000

Analogous toDP->D.

PC->D = T1 AND C0 AND ~C1
Enter fullscreen modeExit fullscreen mode

PC into D function

PC->D signal function in Logisim

D->PC

T+-<>,.][
000001011010110111101100
000000000
1000000--
20000--11
L00000000

Analogous toD->DP

D->PC = T2 AND C0
Enter fullscreen modeExit fullscreen mode

D into PC function

D->PC signal function in Logisim

PC->A

T+-<>,.][
000001011010110111101100
011111111
100000000
20000--00
L11111111

PC->A function is very simple because it's only on during loading and the zeroth cycle.

PC->A = T0 OR L
Enter fullscreen modeExit fullscreen mode

PC into A function

PC->A function in Logisim

PC++

T+-<>,.][
000001011010110111101100
000000000
111111111
20000--00
L11111111

PC++ function is similar to PC->A but instead of being on during the zeroth cycle it's on during the first cycle.

PC++ = T1 OR L
Enter fullscreen modeExit fullscreen mode

PC increment function

PC++ function in Logisim

I/O

T+-<>,.][
000001011010110111101100
000000000
100001100
20000--00
L00000000

The I/O signal is one of the two signals that act immediately when they are turned on: it stops the BPU until the input/output circuit confirms it's ready to perform the operation. This means it can't be on during any other time than the first cycle of I/O commands, except for the nonexistent second cycle of I/O which doesn't help minimise the function.

I/O = T1 AND C0 AND C1
Enter fullscreen modeExit fullscreen mode

I/O function

I/O signal function in Logisim

Next Command

T+-<>,.][
000001011010110111101100
000000000
100000000
200001100
L--------

TheNext Command signal is used to reset the Cycle Counter on the second cycle of I/O commands. It acts by immediately setting the counter to 0 as soon as it's on which prevents it from advancing if it was set at cycle 0. It is free to be on during loading because the counter is reset at that moment anyway. This doesnt't help minimise its function, though.

Next Command = T2 AND C0 AND C1
Enter fullscreen modeExit fullscreen mode

Next Command function

Next Command signal function in Logisim

Conclusion

Almost done!

After putting together all circuits designed in today's tutorial the resulting Command Decoder doesn't fit on the screen, but you can always see and tinker with it by downloading it from thegithub repo. With the final BPU part done next articles will be about connecting everything together and adding some minor circuits and testing, so we're on a home stretch now. Feel free to leave any feedback you have in the comments and see you next time!

Top comments(0)

Subscribe
pic
Create template

Templates let you quickly answer FAQs or store snippets for re-use.

Dismiss

Are you sure you want to hide this comment? It will become hidden in your post, but will still be visible via the comment'spermalink.

For further actions, you may consider blocking this person and/orreporting abuse

A student eager to learn anything except from things taught at school, huge brainfuck fan, author of 2.5 esolangs and lover of everything niche, useless and fun.
  • Location
    Warsaw, Poland
  • Education
    Warsaw University of Technology (studying)
  • Work
    Junior Software Developer at COMP s. a.
  • Joined

More fromAlex Esoposting

DEV Community

We're a place where coders share, stay up-to-date and grow their careers.

Log in Create account

[8]ページ先頭

©2009-2025 Movatter.jp