This section lists error codes, names, and messages that are written to the cluster log in the event of transporter errors.
- 0x00
TE_NO_ERROR
No error
- 0x01
TE_ERROR_CLOSING_SOCKET
Error found during closing of socket
- 0x02
TE_ERROR_IN_SELECT_BEFORE_ACCEPT
Error found before accept. The transporter will retry
- 0x03
TE_INVALID_MESSAGE_LENGTH
Error found in message (invalid message length)
- 0x04
TE_INVALID_CHECKSUM
Error found in message (checksum)
- 0x05
TE_COULD_NOT_CREATE_SOCKET
Error found while creating socket(can't create socket)
- 0x06
TE_COULD_NOT_BIND_SOCKET
Error found while binding server socket
- 0x07
TE_LISTEN_FAILED
Error found while listening to server socket
- 0x08
TE_ACCEPT_RETURN_ERROR
Error found during accept(accept return error)
- 0x0b
TE_SHM_DISCONNECT
The remote node has disconnected
- 0x0c
TE_SHM_IPC_STAT
Unable to check shm segment
- 0x0d
TE_SHM_UNABLE_TO_CREATE_SEGMENT
Unable to create shm segment
- 0x0e
TE_SHM_UNABLE_TO_ATTACH_SEGMENT
Unable to attach shm segment
- 0x0f
TE_SHM_UNABLE_TO_REMOVE_SEGMENT
Unable to remove shm segment
- 0x10
TE_TOO_SMALL_SIGID
Sig ID too small
- 0x11
TE_TOO_LARGE_SIGID
Sig ID too large
- 0x12
TE_WAIT_STACK_FULL
Wait stack was full
- 0x13
TE_RECEIVE_BUFFER_FULL
Receive buffer was full
- 0x14
TE_SIGNAL_LOST_SEND_BUFFER_FULL
Send buffer was full,and trying to force send fails
- 0x15
TE_SIGNAL_LOST
Send failed for unknown reason(signal lost)
- 0x16
TE_SEND_BUFFER_FULL
The send buffer was full, but sleeping for a while solved
- 0x21
TE_SHM_IPC_PERMANENT
Shm ipc Permanent error
Transporter error codes0x17 through0x20 and0x22 are reserved for SCI connections, which are no longer supported in NDB Cluster, and so are not included here.