Demonstration of Synchronous Motor Start by Rotor Polarity Inversion

@article{PrezLoya2018DemonstrationOS,  title={Demonstration of Synchronous Motor Start by Rotor Polarity Inversion},  author={J. Jos{\'e} P{\'e}rez-Loya and C. Johan D. Abrahamsson and Fredrik Evestedt and Urban Lundin},  journal={IEEE Transactions on Industrial Electronics},  year={2018},  volume={65},  pages={8271-8273},  url={https://api.semanticscholar.org/CorpusID:46936078}}
A method to start a synchronous machine without a damper cage is presented, achieved by inverting the polarity of the rotor field winding in a timely manner with respect to the rotating stator field.

Figures and Tables from this paper

11 Citations

Start of a synchronous motor using rotor field polarity inversion and rotor back-emf sensing

Synchronous motors are hard to line start due to torque pulsations at zero rotor speed and low starting torque when started using induced current in a damper squirrel cage. By inverting the rotor

Sensorless High-Torque Start of a Synchronous Motor using Rotor Field Polarity Inversion

Synchronous motors are hard to line start due to torque pulsations at zero rotor speed and low starting torque when started using induced current in a damper squirrel cage. By inverting the rotor

Experimentally validated model of a fast switched salient pole rotor winding

The article proposes a model of a salient pole synchronous machine field winding based on a single transmission line model. An experimental method to derive the parameters is also presented and

The influence of eddy currents on the excitation winding impedance of solid and laminated salient pole synchronous machines

This work investigates the establishment of steady-state eddy currents in solid and laminated salient poles and rotor rim of synchronous machines due to a periodic excitation voltage. It shows that

Continuous Evolution and Modern Approaches of Excitation Systems for Synchronous Machines

A comprehensive survey of the modern approaches of excitation systems for synchronous machines, including the fundamental theory, typical de-excitation methods and excitation equipment topologies is presented.

Excitation System Technologies for Wound-Field Synchronous Machines: Survey of Solutions and Evolving Trends

This contribution presents a comprehensive survey of classical and modern methods and technologies for excitation systems (ESs) of (WFSMs) of wound-field synchronous motors and generators.

Improved Sensorless Control Strategy of High- Power Synchronous Motor for Pumped Storage Power Station

The high-power synchronous motor is widely used in pumped storage power station. An improved sensorless control strategy of synchronous motor is proposed in this paper, which can improve its

An experimentally determined field winding model with frequency‐dependent parameters

In this work a set of experimental procedures is presented for determining the main electrical distributed parameters of the field winding in salient pole synchronous machines. It applies to the el

An Approach for Saving Energy Control of an IM Supplied by the Battery-Powered System Based on Branch-and-Bound Theory

Experiments demonstrate that compared with before optimization, amount of energy consumption of the IM supplied by zinc bromine flow battery decreases by 8.5% and corresponding indicator parameters of the power quality can reach the standard IEC TS62749-2015.

13 References

Analysis of the starting transient of a synchronous reluctance motor for direct-on-line applications

Current industrial trend shows a growing interest towards energy efficiency within industrial processes. In this field, electric motors play a paramount role. Traditionally, high efficiency

Rotor Configurations for Improved Starting and Synchronous Performance of Line Start Permanent-Magnet Synchronous Motor

Analysis, simulation, and experimental results indicate that the proposed rotor configuration leads to improved steady-state performance, by utilizing 10% less magnet volume than the benchmarked spoke rotor.

Analysis of Direct-On-Line Synchronous Reluctance Machine Start-Up Using a Magnetic Field Decomposition

Direct-on-line synchronous reluctance machines combine the characteristics of induction machines and synchronous reluctance machines. Saturation of core materials, the eddy currents, and the

Starting large synchronous motors in weak power systems

Utility company standards for power quality are making it difficult for industrial users to start large induction and synchronous motors due to high inrush current. This paper will present a large

Evaluation of the Efficiency of Line-Start Permanent-Magnet Machines as a Function of the Operating Temperature

The standard squirrel-cage induction machine has nearly reached its maximum efficiency. In order to further increase the energy efficiency of electrical machines, the use of permanent magnets in

An investigation into damper winding failure in a large synchronous motor

This paper deals with operational issues related to a 36-MVA, 11-kV synchronous motor used to drive a reciprocating compressor in a process industry. Extensive damage to the motor's damper winding

Advances on Single-Phase Line-Start High Efficiency Interior Permanent Magnet Motors

A unified analysis of single-phase IPM motor that permits the determination of the steady-state, dynamic, and transient performances is presented and leads to more accurate numerical results and meets the engineering requirements more satisfactorily than any other methods.

Excitation control of the synchronous motor

    R. Schaefer
    Engineering
    Conference Record of 1998 Annual Pulp and Paper…
  • 1998
This paper provides a detailed discussion of the basic theory of operation and control of the synchronous motor. It describes typical synchronous motor starting and provides information regarding

Starting of large motors-methods and economics

The available starting methods are discussed for motors above 3000 hp, focusing on technical and economic aspects. The following schemes are discussed: direct online, reactor start, auto transformer

Large Synchronous Motor Failure Investigation: Measurements, Analysis, and Lessons Learned

In the oil and gas industry, large synchronous motors are used to drive water injection pumps to support the pressure of a reservoir and to maintain the production level of a reservoir over a longer